About this opportunity

The Department of Veterans Affairs Network Contracting Office 5 is conducting market research to identify qualified contractors for a complete arc flash hazard analysis and short circuit study of the electrical distribution system at the Louis A. Johnson VA Medical Center, with furnishing and installing arc flash warning labels on all analyzed equipment, and responses are due 4:00 PM EDT on December 1, 2026. The notice uses no set-aside and is for market research only; it does not constitute a request for quotation or a commitment to contract. The opportunity record is labeled Pre-Solicitation, and the attached notice, 36C24527Q0073, is a Sources Sought Notice. Responses go by email to veronica.dillard@va.gov, and the contracting office is in Linthicum Heights, Maryland. The medical center is in Clarksburg, West Virginia, and the scope covers all buildings and systems there. The work is coded NAICS 334515 and PSC 6625, and responses must state small business status under NAICS 334515, along with UEI, business type, socio-economic status, a capability statement showing arc flash and short circuit experience, and GSA Federal Supply Schedule information if applicable. Responses are not returned, and not responding does not preclude participation in a future solicitation.

The work must be performed under the direct supervision of, and sealed by, a licensed professional engineer. Field personnel must be qualified per NFPA 70E and experienced in occupied healthcare facilities. The work must comply with NFPA 70, 70E, 70B, and 99, IEEE 1584-2018, ANSI/IEEE short circuit standards, ANSI Z535.4, OSHA regulations, and VA specifications. Analysis software must be commercially available and recognized for IEEE 1584-2018 calculations. Drawings and reports are marked Sensitive but Unclassified-Critical Infrastructure Information, and electronic transmissions must use VA-approved secure means without personally identifiable or protected health information.

The contract includes a base period for the initial study and four twelve-month option periods covering model and label updates after facility changes, new equipment studies, post-mitigation analysis, annual verification of at least 15 percent of equipment, annual training, and a five-year comprehensive review. Key deliverables include a work plan due 10 business days after kickoff, a draft report due 60 calendar days after work plan approval with 14-day government review, and installed labels due within 30 days of final report approval.

Notice text

The Department of Veterans Affairs, Network Contracting Office 5 is conducting market research only to determine the availability of qualified Contractors capable of providing complete arc flash hazard analysis and short circuit study of the Louis A Johnson VA Medical Center’s (VAMC) electrical distribution system, and to furnish and install arc flash warning labels on all analyzed equipment.

Files

File Type Posted
Statement of Work-Arc Flash Hazard Analysis Services.pdf PDF
36C24527Q0073.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
H361--LEX Triannual Energy Study and ARC Flash Testing Department of Veterans Affairs Lexington, KY Bowling & Sousley Divisions, Lexington, Kentucky 40511, United States · NAICS 238210 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business
C222--589-27-108, Correct Electrical Deficiencies in Building 26 KCVA (ME) FY27 NRM VISN Base - AE (VA-27-00021035) 4801 Linwood Blvd Kansas City MO 64128 · NAICS 541330 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
APT Generator Switchgear Testing – Alvin C. York VA Medical Center Murfreesboro, Tennessee, United States · NAICS 541380 Veterans Integrated Service Network 9 No set-aside
Z1DA--Project No. 583-22-106- Replace Electrical Panels & Expand Distribution. NAICS 238210 Veterans Integrated Service Network 10 No set-aside
H259--Essential Electrical System (EES) Switch Gear Testing Department of Veteran Affairs San Diego VA Medical Center San Diego CA 92161 · NAICS 811310 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors