About this opportunity

The Department of the Air Force Materiel Command Nuclear Weapons Center seeks installation of a Hirsch Access Control System at Kirtland Air Force Base, with responses due June 7, 2026 at 1400 hours MST. The procurement is 100% small business set-aside under NAICS 561621, Security Systems Services, with a $25 million size standard.

Place of performance is Kirtland Air Force Base, Albuquerque, New Mexico 87117. The vendor must supply and install 14 new keypad readers with motion sensors, 2 new scramble pad readers for read-in access with motion sensors, access control panels and power supplies, and an electronic locking mechanism for double doors on the first floor of Building 66048; re-install 7 existing Hirsch card readers and motion sensors in the newly renovated area; and supply 11 new keypad readers with motion sensors plus access control panels and power supplies on the second floor. The vendor must integrate with the existing Hirsch Access Control System and is explicitly prohibited from proposing Lenel systems, which cannot integrate with the current Integrated Base Defense Security System managed by Air Force Life Cycle Management Center. The vendor must ensure 100% system usability and functionality; exact parts may vary based on vendor evaluation of Government-furnished floor plans. Delivery is F.O.B. Destination with firm fixed pricing. Quotes must remain valid through September 30, 2026. Points of contact are Kristie Netzer (kristie.netzer@us.af.mil) and Contracting Officer Kelly Scott (kelly.scott.8@us.af.mil). The PSC code is 6350.

Notice text

The Government requires the re-installation of 7 Hirsch card readers and motion sensors to
the newly renovated area in Bldg 66048.
- The vendor shall supply, as a minimum:
1st Floor, Bldg 66048
• 14 new keypad readers w/motion sensors
• Two (2) new scramble pad readers for read-in access w/motion sensors
• Access control panels & power supplies to the ACS
• Electronic locking mechanism for the double doors to new mechanical room
2nd Floor, Bldg 66048
• 11 new keypad readers w/motion sensors
• Access control panels & power supplies to the ACS