75 HP Rotary Screw Air Compressor
Closed Solicitation Posted
- Solicitation number
- W50S8V-24-Q-0014
- Agency
-
Army National Guard
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 333912 Air and Gas Compressor Manufacturing
- PSC
- 4310 Compressors And Vacuum Pumps
- Place of performance
- Martinsburg, West Virginia 25405, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The U.S. Army National Guard is seeking quotes for the procurement of a 75 HP Rotary Screw Air Compressor, along with associated equipment and installation services, through Solicitation No. W50S8V-24-Q-0014. The required equipment includes a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), and removal and disposal of the existing air compressor. All quoted products must meet the salient characteristics detailed in the solicitation to be considered technically acceptable. Offers must be submitted to Capt Ryan Belfield via email by August 15, 2024, at 12:00 pm EST.
This requirement is designated as a Total Small Business set-aside under NAICS code 333912 with a small business size standard of 1,000 employees. The place of performance is Martinsburg, WV 25405. The current air compressor is located on the second floor of a maintenance hangar, and the contractor will be responsible for its removal and disposal. A site visit is scheduled for August 1, 2024, and the procurement will be awarded based on price alone without discussions.
Notice text
4 versions
Update #4 · Latest ·
Amendment 0003: Q&A Part 2 document has been uploaded.
Amendment 0002: Q&A document has been uploaded, which also identifies a site visit date of 1 August 2024 at 0900. Contractor to complete the attached background check form and send it to natalie.clower.1@us.af.mil prior to 29 July 2024.
Amendment 0001: This amendment adds FAR clause 52.237-1 Site Visit: Offerors or quoters are urged and expected to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.
Any contractor that wishes to visit the site, please contact Capt Ryan Belfield at 304-616-5412 or ryan.belfield@us.af.mil for scheduling.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
W50S8V-24-Q-0014 – This solicitation is issued as a request for quotation (RFQ)
This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05.
This requirement is designated with a Small Business set-aside of Total Small Business and associated with NAICS code: 333912 and a small business size standard of 1,000 employees.
The 167th Airlift Wing, Martinsburg, WV is requesting a quote for a 75 HP Rotary Screw Air Compressor. This requirement is being requested based on price alone without discussions being held. To be considered technically acceptable you must provide a quote that meets all specifications listed in the saliant characteristics.
This requirement is for the purchase of a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), Installation, and Removal and disposal of old air compressor. ALL QUOTED PRODUCTS MUST MEET THE SALIANT CHARACTERISTICS LISTED BELOW TO BE CONSIDERED TECHNICALLY ACCEPTABLE.
All offers shall be submitted to Capt Ryan Belfield via email at ryan.belfield@us.af.mil prior to 15 August 2024, at 12:00 pm (EST).
SALIENT CHARACTERISTICS
1. One (1) EA Sullair Model TD-543 Direct Driven Rotary Screw Compressor (or equal)
- Must be75hp
- Must direct driven rotary screw
- Must be air cooled
- Must be 460 volt
- Must have 2” npt connections
- Must include three (3) micron coalescing housings and filters with 2” npt connections
- Must have internal or external air dryer tied into compressor to dry the air
2. Three (3) EA Sullair TD-543 Electronic Drains (or equal)
- Must be 110v/1
- Must have 6’ or longer power cord
3. Air compressor that is to be replaced is on the second floor of a maintenance hangar. Contractor is
responsible for removing old compressor from work site. Disposal of old compressor must meet all state and federal regulations.
See attached Combined Synopsis/Solicitation for additional details.
Update #3 ·
Amendment 0002: Q&A document has been uploaded, which also identifies a site visit date of 1 August 2024 at 0900. Contractor to complete the attached background check form and send it to natalie.clower.1@us.af.mil prior to 29 July 2024.
Amendment 0001: This amendment adds FAR clause 52.237-1 Site Visit: Offerors or quoters are urged and expected to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.
Any contractor that wishes to visit the site, please contact Capt Ryan Belfield at 304-616-5412 or ryan.belfield@us.af.mil for scheduling.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
W50S8V-24-Q-0014 – This solicitation is issued as a request for quotation (RFQ)
This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05.
This requirement is designated with a Small Business set-aside of Total Small Business and associated with NAICS code: 333912 and a small business size standard of 1,000 employees.
The 167th Airlift Wing, Martinsburg, WV is requesting a quote for a 75 HP Rotary Screw Air Compressor. This requirement is being requested based on price alone without discussions being held. To be considered technically acceptable you must provide a quote that meets all specifications listed in the saliant characteristics.
This requirement is for the purchase of a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), Installation, and Removal and disposal of old air compressor. ALL QUOTED PRODUCTS MUST MEET THE SALIANT CHARACTERISTICS LISTED BELOW TO BE CONSIDERED TECHNICALLY ACCEPTABLE.
All offers shall be submitted to Capt Ryan Belfield via email at ryan.belfield@us.af.mil prior to 15 August 2024, at 12:00 pm (EST).
SALIENT CHARACTERISTICS
1. One (1) EA Sullair Model TD-543 Direct Driven Rotary Screw Compressor (or equal)
- Must be75hp
- Must direct driven rotary screw
- Must be air cooled
- Must be 460 volt
- Must have 2” npt connections
- Must include three (3) micron coalescing housings and filters with 2” npt connections
- Must have internal or external air dryer tied into compressor to dry the air
2. Three (3) EA Sullair TD-543 Electronic Drains (or equal)
- Must be 110v/1
- Must have 6’ or longer power cord
3. Air compressor that is to be replaced is on the second floor of a maintenance hangar. Contractor is
responsible for removing old compressor from work site. Disposal of old compressor must meet all state and federal regulations.
See attached Combined Synopsis/Solicitation for additional details.
Update #2 ·
Amendment 0001: This amendment adds FAR clause 52.237-1 Site Visit: Offerors or quoters are urged and expected to inspect the site where services are to be performed and to satisfy themselves regarding all general and local conditions that may affect the cost of contract performance, to the extent that the information is reasonably obtainable. In no event shall failure to inspect the site constitute grounds for a claim after contract award.
Any contractor that wishes to visit the site, please contact Capt Ryan Belfield at 304-616-5412 or ryan.belfield@us.af.mil for scheduling.
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
W50S8V-24-Q-0014 – This solicitation is issued as a request for quotation (RFQ)
This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05.
This requirement is designated with a Small Business set-aside of Total Small Business and associated with NAICS code: 333912 and a small business size standard of 1,000 employees.
The 167th Airlift Wing, Martinsburg, WV is requesting a quote for a 75 HP Rotary Screw Air Compressor. This requirement is being requested based on price alone without discussions being held. To be considered technically acceptable you must provide a quote that meets all specifications listed in the saliant characteristics.
This requirement is for the purchase of a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), Installation, and Removal and disposal of old air compressor. ALL QUOTED PRODUCTS MUST MEET THE SALIANT CHARACTERISTICS LISTED BELOW TO BE CONSIDERED TECHNICALLY ACCEPTABLE.
All offers shall be submitted to Capt Ryan Belfield via email at ryan.belfield@us.af.mil prior to 15 August 2024, at 12:00 pm (EST).
SALIENT CHARACTERISTICS
1. One (1) EA Sullair Model TD-543 Direct Driven Rotary Screw Compressor (or equal)
- Must be75hp
- Must direct driven rotary screw
- Must be air cooled
- Must be 460 volt
- Must have 2” npt connections
- Must include three (3) micron coalescing housings and filters with 2” npt connections
- Must have internal or external air dryer tied into compressor to dry the air
2. Three (3) EA Sullair TD-543 Electronic Drains (or equal)
- Must be 110v/1
- Must have 6’ or longer power cord
3. Air compressor that is to be replaced is on the second floor of a maintenance hangar. Contractor is
responsible for removing old compressor from work site. Disposal of old compressor must meet all state and federal regulations.
See attached Combined Synopsis/Solicitation for additional details.
Update #1 ·
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued.
W50S8V-24-Q-0014 – This solicitation is issued as a request for quotation (RFQ)
This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2024-05.
This requirement is designated with a Small Business set-aside of Total Small Business and associated with NAICS code: 333912 and a small business size standard of 1,000 employees.
The 167th Airlift Wing, Martinsburg, WV is requesting a quote for a 75 HP Rotary Screw Air Compressor. This requirement is being requested based on price alone without discussions being held. To be considered technically acceptable you must provide a quote that meets all specifications listed in the saliant characteristics.
This requirement is for the purchase of a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), Installation, and Removal and disposal of old air compressor. ALL QUOTED PRODUCTS MUST MEET THE SALIANT CHARACTERISTICS LISTED BELOW TO BE CONSIDERED TECHNICALLY ACCEPTABLE.
All offers shall be submitted to Capt Ryan Belfield via email at ryan.belfield@us.af.mil prior to 15 August 2024, at 12:00 pm (EST).
SALIENT CHARACTERISTICS
1. One (1) EA Sullair Model TD-543 Direct Driven Rotary Screw Compressor (or equal)
- Must be75hp
- Must direct driven rotary screw
- Must be air cooled
- Must be 460 volt
- Must have 2” npt connections
- Must include three (3) micron coalescing housings and filters with 2” npt connections
- Must have internal or external air dryer tied into compressor to dry the air
2. Three (3) EA Sullair TD-543 Electronic Drains (or equal)
- Must be 110v/1
- Must have 6’ or longer power cord
3. Air compressor that is to be replaced is on the second floor of a maintenance hangar. Contractor is
responsible for removing old compressor from work site. Disposal of old compressor must meet all state and federal regulations.
See attached Combined Synopsis/Solicitation for additional details.
Files
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Hub, air compressor | Land and Maritime | Total Small Business | |
| Compressor, reciprocati | Land and Maritime | Total Small Business | |
| Piston, compressor | Land and Maritime | Total Small Business | |
| Compressor unit, centri | Land and Maritime | Total Small Business | |
| Piston, compressor | Land and Maritime | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity