QA Part 2 - W50S8V-24-Q-0014.pdf
PDF 171 KB Posted
- Attached to
- 75 HP Rotary Screw Air Compressor
- Solicitation number
- W50S8V-24-Q-0014
- Issued by
-
Department of the Army National Guard
About this file
This document is a set of Questions and Answers (Q&A) related to Solicitation No. W50S8V-24-Q-0014 for a 75 HP Rotary Screw Air Compressor. The key details are:
The solicitation is for the purchase of a Sullair Model D-543 75 HP Direct Driven Rotary Screw Air Compressor (or equal), Sullair TD-543 Electronic Drains (or equal), installation, and removal/disposal of the old air compressor. The air compressor must meet specific salient characteristics including being air cooled, 460 volt, with 2" NPT connections, and an internal or external air dryer. The electronic drains must be 110V/1 with a 6' or longer power cord. The old air compressor is located on the second floor of a maintenance hangar, and the contractor is responsible for its removal and disposal. Quotes must be submitted by 15 August 2024 at 12:00 pm EST. This is a small business set-aside requirement under NAICS code 333912 with a size standard of 1,000 employees. The procuring agency is the Department of the Army National Guard.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions & Answers Part 2 for Solicitation No:
W50S8V-24-Q-0014
75 HP Rotary Screw Air Compressor 31 July 2024
Questions:
1. Upon review, it appears the air compressor and drains that were listed as “Brand Name or Equal” have been discontinued. Do you have different model numbers you’d like to use for “Brand Name or Equal”?
A. Yes, air compressor will be “Chicago Pneumatic – Type: CPD75G or equal” and the drains will be “Beko 4025088 BEKOMAT 32 or equal”
2. Does the air compressor need to be portable or stationary?
A. Stationary
3. What is the maximum flow in CFM or ACFM?
A. 312
4. What is the maximum pressure in psig do you require for your application?
A. 150 psi
5. Is it an oil flooded rotary screw or does it need to be oil-free machine?
A. Oil flooded
6. Will the unit require a metal enclosure, less enclosure or quiet enclosure?
A. Yes, the unit will require a metal closure
7. As for the dryer, is a 38-dewpoint sufficient or do you require a -40-degree dewpoint instrument quality?
A. 38-degree