About this opportunity
The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 1 is seeking to procure a wall-mounted, ultrapure and pure water filtration system to provide point-of-use water for specific laboratory demands at the VA Bedford Healthcare System. The key requirements include a water dispensing unit that produces filtered water from tap water at a rate of 5L per hour, with variable flow and the ability to dispense specific volumes from 20mL to 100L. The system must utilize reverse osmosis and electrodeionization technologies to ensure pure and deionized water quality that meets stringent purity requirements for use in applications like immunocytochemistry, DNA/RNA assays, and mass spectrometry. The system must have a compact footprint not exceeding 35"H x 50"W x 30"D and a low-noise DC pump generating less than 52 decibels.
This is a total small business set-aside procurement with a NAICS code of 334516 (Analytical Laboratory Instrument Manufacturing) and a PSC of 6640-P (Laboratory Equipment And Supplies). The solicitation number is 36C24124Q0861, and responses are due by 08-23-2024 at 12:00pm Eastern Time. The place of performance is the VA Bedford Healthcare System located at 200 Springs Rd, Bedford, MA 01730.
Notice text
P09 PERFORMANCE WORK STATEMENT & SALIENT CHARACTERISTICS
Salient Characteristics and PWS
VA Bedford Healthcare System requires a wall-mounted, ultrapure and pure water filtration system to provide point-of-use water for specific laboratory demands including immunocytochemistry, immunohistochemistry, biochemical assays for DNA and RNA, and mass spectroscopy.
The commodity/equipment shall include a PURE and ULTRA-PURE water dispensing unit that produces filtered water directly from a tap water source with a typical water production rate of 5L per hour and variable flow water dispensing. The volumetric water dispensing should deliver a specific water volume, from 20mL to 100L automatically (with 1 mL incremental). The ultrapure water system shall utilize Reverse Osmosis (RO) technology where pump pressure is temperature and resistivity compensated to keep water production rate constant, and the system shall ultilize Electrodeionisation (EDI) technology to ensure constant pure and deionized water which is required for our HPLC, immunocytochemistry and DNA/RNA assays.
Space Specifications:
Due to laboratory space and bench to ceiling constraints, the footprint of all components must not exceed 35 H x 50 W x 30 D.
The ultrapure water system will utilize a low-voltage DC pump which will generate less than 52 decibels of sound at one meter from the system for virtually silent operation.
Electrical and Water Specifications
ELECTRICAL REQUIREMENTS: .120V
MINIMUM INLET PRESSURE: .1 to 6 bar
Other Purification Technology requirements:
Water system has a UV lamp with emission at 265 nm to inactivate bacteria. For safety reasons and hazardous waste management this is preferably a mercury-free lamp.
Water system also uses a UV lamp with emission at 172 nm to reduce remaining dissolved organic contamination and destroy bacteria, thus reducing background noise in all assays. For safety reasons and hazardous waste management this is preferably a mercury-free lamp.
Additionally, storage tank has a UV lamp with 265 nm emission to inactivate bacteria and prevent biofilm formation within the system at all times. For safety reasons and hazardous waste management this is preferably a mercury-free lamp.
Storage tank has an electronic overflow sensor and pressure sensor to allow the system to run afterhours as needed when water is depleted at the end of the day without risk of flooding.
System will have 3 point-of-use filters for additional bacteria control and removal of larger biological structures, pyrogens, endotoxins, RNases, DNases and proteases.
Pure (Type 2) water production requirements:
Point-of-Use Water Delivery Flow Rate up to 2L/min
Pure Water Resistivity (M .cm at 25°C) > 5
Microorganisms (cfu/mL) < 0.01
Particulates < 0.22 m (/mL) < 1
Pyrogen Levels (EU/mL) < 0.001
RNase Level (ng/mL) < 0.01
DNase Level (pg/ L) < 4
TOC (ppb) < 30
Ultapure (Type 1) water production requirements for DNA/RNA/ELISA assays:
Point-of-Use Water Delivery Flow Rate 0.05 to 2L/min
UltraPure Water Resistivity (M .cm at 25°C) 18.2
Microorganisms (cfu/mL) < 0.01
Particulates < 0.22 m (/mL) < 1
Pyrogen Levels (EU/mL) < 0.001
RNase Level (ng/mL) < 0.01
DNase Level (pg/ L) < 4
Proteases (ug/ml) -
Files
| File | Type | Posted |
|---|---|---|
| 36C24124Q0861_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6640-- Lab Water Purification System BRAND NAME OR EQUAL to Millipore Milli-Q IQ 7005 | Pre-Solicitation | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Capital Equipment: Purchase of (1) Millipore Sigma | EPA Region 2 | No set-aside | |
| AFIT/ENG-Cleanroom DI-RO Type I Ultra-Pure Water System | AFLCMC Wright Patterson AFB | No set-aside | |
| F109--Water Management Program and Chemical Testing Amendment 001- Q&A | Veterans Integrated Service Network 1 | Service-Disabled Veteran-Owned Small Business | |
| F103--D and D laboratory steam & water testing | Veterans Integrated Service Network 6 | Veteran-Owned Small Business | |
| J065--RO Equipment Maintenance RFQ Amendment to Answer Industry Questions | Veterans Integrated Service Network 10 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity