6515--Temperature Management Machine
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C25524Q0599
- Agency
- Veterans Integrated Service Network 15 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Points of contact
-
- Kevin Mahoney kevin.mahoney3@va.gov (913) 684-0141
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15 is seeking to procure a Temperature Management Machine under solicitation number 36C25524Q0599. The machine must be compatible with the agency's existing Phillips vital sign monitoring equipment, with specific requirements for water and patient temperature control ranges, accuracy, and operating modes. The agency requires the machine to be able to supply individual or multiple thermal transfer devices simultaneously. Key contract objectives include closed-loop control, visual and audible safety alarms, and a system status display.
This procurement is set aside for Service-Disabled Veteran-Owned Small Business Concerns. The NAICS code is 339112 - Surgical and Medical Instrument Manufacturing, and the PSC is 6515 - Medical And Surgical Instruments, Equipment, And Supplies. Responses are due by September 6, 2024 at 4:00 PM Central Time. The Point of Contact is Contract Specialist Kevin A Mahoney.
Notice text
Statement Of Work
MUST be Compatible with Phillips vital sign monitoring equipment currently used at the facility
Due to periodic saline shortages we require a resevour
Water Temperature
Control setting range: 39.2-104.0 F
Control accuracy: + or 0.3 C
Display measurement accuracy: + or 0.2 C
Display/resolution setting: 0.1C
Default setting: 104.F (40.0C)
Patient Temperature
Control setting range: 89.6-100.4F
Control accuracy: = or 0.1 C
Default setting: 98.6F
Circulating Fluid: Sterile distilled water or distilled water
Thermal transfer devices such as blankets, vests, and leg wraps
Patient temperature probes
Reusable adapter cables
Reusable hose sets
Reusable patient temperature output cable
Must be capable of supplying either an individual or multiple thermal transfer devices simultaneously with those circuits being monitored separately.
Must have 3 operating modes: Automatic, Manual, and Monitor
Closed loop control
Controller alarms visual and audible indications for when safety parameters are exceeded or it detects system function or performance irregularities.
A display to inform of system status or when the user must confirm a setting selection.
Attachments
| File | Type | Posted |
|---|---|---|
| 36C25524Q0599_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--Temperature Management Machine | Award Notice | |
| 6515--Temperature Management Machine | Solicitation | |
| 6515--Temperature Management Machine | Pre-Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity