The Department of Veterans Affairs Network Contracting Office (NCO) 19, on behalf of the Oklahoma VA Health Care System, is conducting market research to identify domestic manufacturers capable of supplying and installing ten steam sterilizers equivalent to the Steris AMSCO 400 Small Steam Sterilizer. This Sources Sought Notice is not a formal solicitation but rather a voluntary request for capability information to inform the government's procurement strategy. Interested contractors must demonstrate their capability to provide domestically manufactured products compliant with the Buy American Act and must submit detailed capability statements by March 20, 2026 at 11:59 PM Mountain Time to Shanta Harrison at Shanta.Harrison@va.gov. The steam sterilizers must meet specific technical requirements including a 20" x 20" x 38" chamber with prevacuum capability, single-door external steam supply, standard Venturi configuration with single-phase power, ISO/AAMI 15883 compliance, rapid cycle times, and user-friendly touch screen interfaces. Additionally, a comparable washer/disinfector unit (AMSCO 7053HP) with 200-208V, 3-phase, 60Hz capability and 15 DIN/10 US tray capacity is required. Prospective offerors should include company point of contact information, business size status, and documentation supporting organizational and staff capability in their responses.

This procurement involves no set-aside designation and will result in a firm-fixed price contract awarded through full and open competition, with the possibility of multiple awards. The Steris AMSCO 400 Small Steam Sterilizer is identified as the incumbent equipment standard, though this notice is seeking comparable alternative manufacturers. No specific budget range or award value has been disclosed in the pre-solicitation materials. The requirement encompasses ten units of the primary steam sterilizer and an unspecified quantity of the washer/disinfector units, classified under NAICS code 339113 (Surgical Appliance and Supplies Manufacturing) and Product Service Code 6515 (Medical and Surgical Instruments, Equipment, and Supplies). The procurement timeline indicates the government is actively conducting market research as of March 17, 2026, with formal solicitation anticipated to follow based on the capability information received.

Notice text

The Department of Veterans Affairs Network Contracting Office (NCO) 19, Oklahoma VA Health Care System is issuing this Sources Sought Notice as a means of conducting market research to identify DOMESTIC MANUFACTURERS having an interest in, and the resources to support this requirement for STEAM STERILIZERS similar or equivalent to the Steris AMSCO 400 Small Steam Sterilizer, for the Oklahoma VA Health Care System located at 921 NE 13th St, Oklahoma City, OK 73104. The results of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 339113 - Surgical Appliance and Supplies Manufacturing.

This is a request for information and sources only, which may or may not lead to a future solicitation! This is not a solicitation. This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. Contractor shall provide all labor, parts, supplies and equipment necessary to supply and install the STEAM STERILIZERS. Services shall include but are not limited to the following:

Objective: The Oklahoma City VA Health Care System (OKC VAHCS) requires 10 (ten) Steam Sterilizers to meet the need of the Sterile Processing Service (SPS) at the Oklahoma City medical facility. This procurement will result in a new, firm-fixed price contract.

The OKC VAHCS is seeking only domestically manufactured products to fulfill this requirement, pursuant to the Buy American Act.

SALIENT CHARACTERISTICS requested for the desired Small Steam Sterilizers are as follows:

high-capacity chamber that has been validated to sterilize.

20" x 20" x 38"

Prevacuum

Single Door

External Supplied Steam (Facility Steam/Stand-Alone Generator)

Standard configuration with a Venturi - single phase power only

Recessed

LH

Washer/Disinfector (comparable to AMSCO 7053HP)

200-208V

3 Ph

60 Hz

Steam Heated

15 DIN/10 US tray capacity

ISO/AAMI 15883 compliant

Rack Return includes 2 interlocked doors with hands-free sensors

and command button

The AMSCO® 400 Series Steam Sterilizers are known for high-volume processing capabilities, compliance with industry standards, and advanced water/energy-saving technology.Â

Additional key salient characteristics include:

1. High Efficiency and Quick TurnaroundÂ

Rapid Cycle Times:Â Designed for quick turnaround of heat- and moisture-stable instruments.

Immediate-Use Sterilization:Â Features validated immediate-use (formerly "flash") prevacuum and gravity cycles.

High Capacity:Â Smaller units handle up to 250 lbs.

Reduced Utility Usage:Â Software and design features (such as an optional water-saving vacuum pump) reduce water consumption by up to 60% and improve energy efficiency.Â

2. Key Design and Structural Features

Non-Lubricated Gasket:Â Industry-only non-lubricated, steam-activated door gasket with a 2-year warranty.

Vertical/Horizontal Door Options:Â Small units feature a vertical sliding door with a foot pedal for hands-free, ergonomic operation. Medium units offer manual hinged or horizontal sliding doors.

Construction:Â The vessel is fully jacketed to minimize condensation, and all piping is modularized for easier maintenance.

Flexible Installation:Â Units can be recessed into a wall or free-standing/cabinet-enclosed.Â

3. Advanced Control System

Touch Screen Interface:Â User-friendly controls allow for easy cycle selection, monitoring, and programming.

Customizable Cycles:Â Users can name and configure cycles to meet specific facility requirements.

Validated Performance:Â All cycles are validated to AAMI/AORN standards.

Data Management: Includes a thermal printer for recording, and is compatible with remote monitoring systems like ProConnect® Response Center and ConnectAssure Technology.Â

4. Specialized Features

Optional SFPP Cycle:Â Steam Flush Pressure Pulse (SFPP) is available to eliminate the need for daily Bowie-Dick testing.

Automatic Utilities Management:Â Programmable startup/shutdown lowers utility costs by shutting off steam and water during idle times.

Safety Features:Â Includes automatic door locking mechanism, power door safety features to stop movement on obstruction, and a chamber float switch to prevent excessive condensate.

BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION, and multiple awards MAY be made. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions. SUBMISSION INSTRUCTIONS: If your organization can provide these services and is interested in this opportunity, please respond to Shanta Harrison, Contract Specialist, Department of Veterans Affairs, NCO 19 via e-mail at Shanta.Harrison@va.gov with a statement describing your capabilities. The capability statement shall include a primary point of contact, complete mailing address, telephone number, email address, state the company s business size status and should address this specific requirement, with appropriate documentation supporting claims of organizational and staff capability. Please be as thorough as possible in your submission, and include information on any multiple award schedule contracts your company holds. Requests for copies of a solicitation will not be honored or acknowledged. Expedited responses are requested. The deadline for responses is Friday, March 20, 2026 at 11:59 PM mountain time.

Files

File Type Posted
36C25926Q0333.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
7125--Sterile Storage Cabinets VA Greater Los Angeles (GLA) Healthcare System Los Angeles CA 90073, United States · NAICS 339113 Veterans Integrated Service Network 22 No set-aside
DA10--Steris Software Connectivity Fresno CA 93703, United States · NAICS 541519 Veterans Integrated Service Network 21 No set-aside
Neuro Micro Instruments Houston, Texas 77030, United States · NAICS 339112 Veterans Integrated Service Network 16 No set-aside
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular Department of Veterans Affairs VA Caribbean Healthcare System San Juan PR 00921 · NAICS 339112 Veterans Integrated Service Network 8 No set-aside
Getinge Steam Sterilizer Repair Japan · NAICS 811210 Naval Supply Systems Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors