6515--Sources Sought Welch Allyn GS-777 Integrated Wall Diagnostic Systems for the Hines VAMC
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25226Q0686
- Agency
-
Veterans Integrated Service Network 12
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339113 Surgical Appliance and Supplies Manufacturing
- Place of performance
- Hines Vamc Zip 60141
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Integrated Service Network 12, is conducting market research through the Great Lakes Acquisition Center to identify qualified vendors to supply Welch Allyn brand or equivalent integrated wall-mounted diagnostic systems for the Hines VAMC, with responses due August 25, 2026. The VA is assessing vendor availability across Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), small or emerging small business, and other than small business categories.
Place of performance is Hines VAMC, Illinois (ZIP 60141). The equipment must be designed for permanent wall installation in outpatient exam rooms and support Primary Care and Community-Based Outpatient Clinics. Required salient characteristics include automated non-invasive blood pressure measurement, integrated pulse oximetry and temperature measurement, integrated otoscope and ophthalmoscope, centralized power and cable management, clinical-grade durability for high-volume use, smooth non-porous surfaces compliant with VA infection prevention standards, and compatibility with standard clinical supplies without proprietary consumables. Installation and training requirements must be minimal.
Respondents must submit company name, address, point of contact, FSM/SEWP contract numbers if applicable, SAM Unique ID, tax ID, business category classification, a capability statement, and manufacturer authorization documentation. This is a sources sought notice only and not a request for quote. Contracting officer is Ray Moore (Ray.moore@va.gov). PSC 6515; NAICS 339113 (Surgical Appliance and Supplies Manufacturing, 800-employee size standard).
Notice text
Page 2 of 3
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR QUOTE.
The NCO 12, Great Lakes Acquisition Center, 115 S. 84th Street, Suite 101, Milwaukee, WI 53214, is performing market research to determine if there is a sufficient number of qualified: (1) Service Disabled Veteran Owned Small Business (SDVOSB); (2) Veteran Owned Small Business (VOSB); or (3) Small or emerging small business firms, or (4) Other Than Small business firms, to provide wall-mounted diagnostic systems for outpatient exam rooms For the Hines VAMC.
General Requirements: Welch Allen Brand Name or Equal
Salient Characteristics:
The proposed equipment must meet or exceed the following minimum salient characteristics to satisfy the Government s clinical and operational needs:
Integrated Wall-Mounted Diagnostic System
Designed for permanent wall installation in outpatient exam rooms.
Supports efficient clinical workflows in Primary Care and Community-Based Outpatient Clinics (CBOCs).
Vital Signs Measurement Capabilities
Automated non-invasive blood pressure (NIBP) measurement.
Integrated pulse oximetry (SpO ).
Integrated temperature measurement capability.
Clinical Examination Instruments
Integrated otoscope with adequate illumination for routine ear examinations.
Integrated ophthalmoscope suitable for routine eye examinations.
Centralized Power and Cable Management
Single integrated power source to reduce cable clutter.
Organized instrument docking to promote safety and equipment readiness.
Durability and Clinical-Grade Construction
Designed for high-volume outpatient clinical use.
Capable of withstanding repeated daily use in Primary Care exam rooms.
Infection Control and Cleanability
Smooth, non-porous surfaces suitable for routine clinical disinfection.
Supports VA infection prevention and control standards.
Compatibility with Standard Clinical Supplies
Uses commonly available clinical accessories such as blood pressure cuffs and probe covers.
Does not require proprietary or dedicated consumables to operate.
Minimal Installation Requirements
Wall-mounted installation with no requirement for structural modification beyond standard mounting.
No specialized utilities required beyond standard electrical service.
Training Requirements
Minimal operator training required due to similarity with existing VA diagnostic equipment.
Vendor-provided documentation or orientation sufficient for staff onboarding.
All interested firms who can meet the requirements stated above should respond, in writing,
INCLUDING ALL THE FOLLOWING:
Company name.
Address.
Point of contact (name/title/telephone number/e-mail address).
FSS / SEWP Contract number, if applicable.
SAM Unique ID number.
Tax ID number.
Indication of which business category (SDVOSB, VOSB, Small Business or Other Than Small Business) for which the organization qualifies.
A capability statement that addresses the organizations qualifications and ability to provide the requirement depicted above.
Documentation from manufacturer (i.e. correspondence from manufacturer) of your firm being an authorized distributor for the manufacturer.
Submit responses to the Contracting Specialist, Matthew Hohl, at Matthew.Hohl@va.gov no later than 11:59 PM (Central Standard Time), August 24th, 2026.
36C25226Q0686 wall-mounted diagnostic systems for outpatient exam rooms-2346 shall be referenced on all correspondence regarding this announcement.
TELEPHONIC INQUIRIES WILL NOT BE ACCEPTED.
The NAICS Code 339113, Surgical Appliance and Supplies Manufacturing, is applicable to this acquisition; the size standard is 800 employees. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Systems for Award Management (SAM) database prior to award of a contract. The Government will use responses to this notice to make an appropriate acquisition decision. This is the only notice; no other copies of this notice will be provided.
Files
| File | Type | Posted |
|---|---|---|
| 36C25226Q0686.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Pre-Solicitation | |
| 6515--Sources Sought Welch Allyn GS-777 Integrated Wall Diagnostic Systems for the Hines VAMC | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| N065--Slit Lamp Installation for the Captain James A. Lovell Federal Health Care Center (FHCC), located at 3001 Green Bay Rd. , North Chicago, IL 60064. | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| J065--Intent to Sole Source Hines VA Base 2 Carto 3 EP Cath Lab Service | Veterans Integrated Service Network 12 | No set-aside | |
| Neuro Micro Instruments | Veterans Integrated Service Network 16 | No set-aside | |
| 6540--Carl Zeiss Visulas Combi YAG Green (VA-26-00065932) | Veterans Integrated Service Network 12 | No set-aside | |
| 6515--BRAND NAME ONLY- Philips ST80i Stress Test System | Veterans Integrated Service Network 4 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity