6515--Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)

Closed Pre-Solicitation Posted

Solicitation number
36C25927Q0016
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs Oklahoma City VA Medical Center Oklahoma City, Oklahoma 73104, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration, Network Contracting Office 19 (NCO 19), is conducting market research to identify potential sources for the purchase of one QS3 qPCR System, one iBright FL1500 Imaging System, and associated accessories for the Oklahoma City VA Medical Center (OKCVAMC), with responses due October 15, 2026 at 09:00 MST. This is a Sources Sought Notice issued for information and planning purposes only and does not constitute a solicitation; responses cannot be accepted to form binding contracts, and the Government will not compensate respondents for response costs.

Place of performance is the Oklahoma City VA Medical Center, located at 921 NE 13th Street, Oklahoma City, Oklahoma 73104. The equipment will support research into osteoarthritis treatment and pain management.

Interested contractors must submit a Capabilities/Qualifications Statement, overview of proposed solutions, product descriptions, and completion of a market research questionnaire addressing business size, GSA/FSS contract holder status, pricing model, Buy American Act compliance, and nonmanufacturer rule questions. Submissions are limited to 8 pages including a cover letter and must be marked "Proprietary Information" if business sensitive.

The VA has identified NAICS Code 334516 (Analytical Laboratory Instrument Manufacturing) as appropriate, with a small business size standard of 1,000 employees. Responses are due via email to devin.reichert@va.gov and will be retained for 30 days after the response date.

Notice text

Sources Sought Notice Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC)

Disclaimer:

This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Information Requested from Industry:

In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the Statement of Work draft / Salient Characteristics List.

Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.

Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Purchase of One (1) QS3 qPCR System, One (1) iBright FL1500 Imaging System, and Associated Accessories, Brand Name or Equal To for Oklahoma City VA Medical Center (OKCVAMC) for Oklahoma City VA Medical Center (OKCVAMC). This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.

Brand Name or Equal to QS3 qPCR System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:

Description

Part Number

Qty

QS3 0.1 mL qPCR System with Laptop

A28566

1

Fast 96 Well RNase P Verification Plate

4351979

1

Fast 96 Well Hardshell Clear Plate (20 pack)

4483485

1

Optical Adhesive Covers (25 per pack)

4360954

1

802.11ac/b/g/n Wi Fi Dongle

A26774

1

Fast 96 Well ROI & Background Plates

4432426

1

PowerTrack SYBR Master Mix, 1 mL

A46012

1

TaqMan Fast Advanced Master Mix, 1 mL

4444556

1

SmartStart qStudio 3 Orientation

A28806

1

Salient Characteristics:

System and Consumables

QuantStudio 3 Real-Time PCR System

Compatible with Applied Biosystems MicroAmp EnduraPlate optical 96-well fast clear reaction plates

Supports barcoded, 0.1 mL reaction plates

Includes or identifies the quantity of plates provided

Identifies any additional consumables required for operation

Thermal Control and Block Configuration

96-well sample block

At least three independently controlled Peltier temperature zones

Programmable temperature difference of up to 10°C across the block

Maximum temperature difference of 5°C between adjacent zones

Block temperature range of approximately 4°C to 99.9°C

Reaction Volumes and Thermal Performance

Supports reaction volumes of approximately 10 30 µL on a 0.1 mL block

Supports reaction volumes of approximately 10 100 µL on a 0.2 mL block

Maximum ramp rate of approximately 9.0°C per second for the 0.1 mL block

Maximum ramp rate of approximately 6.5°C per second for the 0.2 mL block

Optical Detection and Heated Cover

Long-life white LED light source with a median operating life of at least 60,000 hours

CMOS imaging system for data acquisition

Data collection for each filter combination in less than two seconds

Heated cover temperature range of approximately 50°C to 110°C

Heated cover designed to minimize evaporation from reaction plates

Storage, Connectivity, Power, and Reliability

Compatible with the Connect platform

Provides up to 1 TB of cloud-based storage

Includes approximately 10 GB of onboard storage

Stores approximately 1,000 5,000 standard absolute-quantification run files

Compatible with 100 240 V electrical outlets without modification

Provides run protection during network or power interruptions

Includes information on data security, software requirements, warranty, technical support, maintenance, training, and recurring storage or software costs

Brand Name or Equal to iBright FL1500 Imaging System - Qty 1. The offer must meet the capabilities of the line items listed in addition to the following salient characteristics:

Description

Part Number

Qty

iBright FL1500 Imaging System

A44241

1

SmartStart iBright Orientation

A34016

1

1 Preventive Maintenance visit for iBright FL1500

ZG61SCIB

1

Bolt Welcome Pack with iBlot 3

NW0412AI

1

iBright Protein Standard (25 µL)

LC5605

1

iBright FL1500 2 Year Warranty

1

Salient Characteristics:

Imaging Capabilities and Performance

Chemiluminescent western blot imaging

Protein gel, DNA gel, membrane, and stained SDS-PAGE gel imaging

Automatic image capture, focus, exposure, and analysis

Quantitative band analysis and background subtraction

High sensitivity, broad dynamic range, and low-light detection

Imaging of multiple samples, including up to four mini gels in one view

Camera, Detection, Illumination, and Imaging Area

Cooled scientific-grade CCD camera

At least 16-bit image capture and approximately 9-megapixel resolution or higher

Adjustable pixel binning and optical/digital zoom

Imaging area of approximately 22.5 cm by 18 cm or larger

Removable sample tray

White-light and blue/green-light illumination

Optional near-infrared illumination

Chemiluminescent detection, multiple filter options, and long-life LED light sources

Interface, Software, Storage, and Connectivity

Integrated touchscreen and internal computer or workstation

Automated focus, exposure, zoom, image enhancement, quantification, annotation, reporting, and analysis

Molecular-weight analysis, where applicable

TIFF, JPEG, PNG, PDF, and other common image formats

At least 250 GB of internal storage

USB and Ethernet connectivity

Optional wireless or cloud connectivity

Secure data transfer, user access controls, and software updates

Accessories and Training

Sample tray, imaging accessories, and white screen or equivalent for stained-gel imaging

User manuals, quick-start guides, installation instructions, and training materials

3. Scope:

The Oklahoma City VA Medical Center requires the Applied Biosystems QS3 qPCR System, iBright FL1500 Imaging System, and associated accessories to support research into osteoarthritis treatment and pain management.

4. Delivery:

Department of Veterans Affairs

Oklahoma City VA Medical Center

921 Northeast 13th Street

Oklahoma City, OK 73104-5007

In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:

NAICS Code: 334516

Company Name:

Address:

UEI (Unique Entity ID) Number:

Contact Name:

Phone No.:

Email:

Business Size Information - Select all that applies:

Small Business

Emerging Small Business

Small Disadvantaged Business

Certified under Section 8(a) of the Small Business Act

HUBZone

Woman Owned

Certified Service-Disabled Veteran Owned Small

Veteran Owned Small Business

Large Business

FSS/GSA Contract Holder:

Yes No

FSS/GSA Contract Number:

Effective Date/ Expiration Date:

Proposed solution is listed and available on the above FSS/GSA Contract:

Yes No

Pricing Model

Please Indicate Availability Below: (Yes / No / NA)

All on FSS

Open Market only

Mix of FSS & Open Market

Firm-Fixed Price

Federal Acquisition Regulation (FAR) Market Rearch Questions:

Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:

Domestic end product? _____________ (%)

Foreign end product? _______________ (%) Country of Origin:

Questions for Small Businesses ONLY:

If subcontracting, what added value do you offer (RFO 52.215-23):

Nonmanufacturer Rule (RFO 52.219-33):

Does your company manufacturer these proposed items? [Â ] yes [Â ] no

Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________

Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no

Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no

Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________

Response Instructions:

Do not provide more than 8 pages, including cover letter page.

Submit your response via email to devin.reichert@va.gov

Submit your response NLT 09:00 (MST) on October, 15th, 2026;

Mark your response as Proprietary Information if the information is considered business sensitive.

VA has identified the appropriate North American Industry Classification System (NAICS) Code as 334516 (Analytical Laboratory Instrument Manufacturing) with a Small Business size of 1000 Employees. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.

(End of Document)

Files

File Type Posted
36C25927Q0016.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065--Notice of Intenet to Sole Source- Life Technologies Corporation Maintenance and Service for QuantStudio 12K Flex Real-Time Quantitation System NAICS 811210 Veterans Integrated Service Network 16 No set-aside
6550--Cepheid GeneXpert Testing Supplies Beckley Vamc Clarksburg Vamc Vamhcs Washington Vamc · NAICS 325413 Veterans Integrated Service Network 5 No set-aside
6550-- Roche Ventana Reagents IDIQ 5 Successive 1 Year Delivery Orders Slvhcs New Orleans, Louisiana 70119, United States · NAICS 325413 Veterans Integrated Service Network 16 No set-aside
6632--FY27 Microbial Incubation ID and Susceptibility CPT James A. Haley Veterans' Hospital Tampa, Florida 33612, United States · NAICS 334516 Veterans Integrated Service Network 8 No set-aside
NX EQ Microscope Spine United States · NAICS 339113 VA Strategic Acquisition Center Frederick No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors