About this opportunity

The Department of Veterans Affairs (VA) Veterans Health Administration, specifically Network 23 Contracting Office, is conducting market research for a brand-name procurement of an Interacoustics Micromedical Orion Reclining Rotary Chair system. The sophisticated medical equipment includes a rotary chair with advanced vestibular and oculomotor testing capabilities, a caloric irrigator, VNG TV, OtoAccess Database, and an EyeSeeCam vHIT system. Potential vendors must submit detailed responses by 10:00 am CST on April 16, 2025, to james.miller4@va.gov, providing comprehensive company information including distribution capabilities, contract schedules, SAM UEI number, and business size/socioeconomic status. Respondents must be Original Equipment Manufacturer (OEM) authorized dealers offering new, warranty-covered equipment, and must demonstrate the ability to meet highly specific technical requirements for medical diagnostic testing. This Request for Information (RFI) is a market research initiative and does not guarantee a future solicitation or contract award.

The procurement is not currently set aside for any specific business category, though vendors are asked to declare their business classification, including options like small business, service-disabled-veteran-owned small business, or women-owned small business. The equipment will be delivered to the NWI VA Health Care System located in Omaha, Nebraska, with installation included as part of the potential procurement. While no specific award value is mentioned, the complexity of the equipment suggests a significant investment in advanced medical diagnostic technology. The procurement falls under NAICS Code 334510 for Electromedical and Electrotherapeutic Apparatus Manufacturing and Product Service Code 6515 for Medical and Surgical Instruments and Equipment. The VA emphasizes that this is a voluntary information-gathering process, with no guaranteed contract or reimbursement for response preparation, and reserves the right to use submitted information for future acquisition planning.

Notice text

NO PHONE CALLS PLEASE

RFI / Sources Sought: 36C26325Q0655

The DEPARTMENT OF VETERANS AFFAIRS, Network 23 Contracting Office is conducting research and is issuing this Request for Information to learn of the availability and capability of business sources qualified to provide the items listed below as Brand-Name Only. This is NOT a solicitation.

SUBJECT: Interacoustics Micromedical Orion Reclining Rotary Chair Brand Name Only.

NAICS CODE: 334510

PSC: 6515

INTERESTED SOURCES SHALL RESPOND BY:

All responses must have the VA RFI Number in the Subject Line of the email!!!

All responses must be received no later than 10:00am CST, Wednesday, April 16, 2025

All responses must be submitted to this email address: james.miller4@va.gov

POTENTIAL SOURCES SHALL PROVIDE THE FOLLOWING INFORMATION IN THEIR RESPONSE:

Company name, address, phone number, primary contact(s), e-mail address.

State if your firm distributes the Brand-Name items or Equal items.

State if your firm has the required items on a Schedule (GSA, FSS, NAC, etc). If so, include contract number and expiration date.

SAM UEI number for your firm

State if your firm is a large business, small business, service-disabled-veteran-owned

small business, veteran-owned small business, HUB zone 8(a), women-owned small business or a small-disadvantaged business.

If your firm is a Socio-economic small business (WOSB, VOSB, SDVOSB ), state if your firm is a Non-Manufacturer under the Non- Manufacturing Rule. Information regarding the Non-Manufacturer Rule can be found at these links:

Nonmanufacturer rule | U.S. Small Business Administration (sba.gov)

-OR-

https://www.sba.gov/partners/contracting-officials/small-business-procurement/nonmanufacturer-rule#:~:text=What%20is%20the%20nonmanufacturer%20rule,if%20it%20is%20a%20nonmanufacturer

BRAND-NAME ONLY MODEL AND TECHNICAL SPECIFICATIONS:

Interacoustics Micromedical Orion Reclining Rotary Chair Brand Name Only

8526809 Micromedical Orion Reclining Rotary Chair with VE525 VNG, Top

Mounted Goggles, RF Remote Control, Equipment Cart, Printer, ISO Transformer, VE525 Software, OtoAccess Database Small Form Factor PC, DOES NOT INCLUDE TV

Capability to complete the following tests in an integrated and non-enclosed reclining rotational chair system: sinusoidal harmonic acceleration from .01Hz to .64Hz, step velocity testing up to 200 degrees/second, visual ocular reflex (VOR) suppression testing from .01Hz to .64Hz, visual VOR with large screen monitor included, and oculomotor tests including gaze, smooth pursuit, saccades, saccadometry, and optokinetics, and dynamic visual acuity (DVA), active head rotation (AHR), and gaze stabilization testing (GST), and integrated VHIT testing including Suppression Head Impulse Test (SHIMP) with patient worn goggles.

In rotational mode the chair must have no more than a 2-foot, 6-inch rotational clearance space around base and no more than 6-foot, 6-inch diameter swing safety arc around the chair base.

Capability to recline to multiple angles, precisely recline to 30-degrees for caloric testing and fully-recline to zero degrees with removable headrest for Dix-Hallpike testing and positional maneuvers.

Non-remote goggle-integrated VHIT test camera measures and displays graphical presentation of head versus eye movements for all 6 semicircular canals and provides a 3D anatomically correct model in software of semicircular canals and includes Suppression Head Impulse Test (SHIMP).

8503836 Micromedical Air FX Caloric Irrigator Lighted Otoscope with Disposable Speculums, Flow Rate of 8 Liters Per Minute, Active Cooling Below Room Temperature, 9 Foot Irrigator Hose, USB Interface to Spectrum VNG Software, Front Panel Push Buttons for Temperature and Time.

/VNG TV VNG TV, Bracket & Cable

8517470 OtoAccess Database

8525982 Interacoustics EyeSeeCam vHIT Includes: EyeSeeCam vHIT Goggles, Software & Manuals CD, EyeSeeCamSoftware, Carrying Case

INSTALLATION Installation - ___

Delivery: NWI VA Health Care System - Omaha

4101 Woolworth Ave

Omaha, NE, 68105

NOTICE TO ALL RESPONDENTS:

The Vendor shall be an Original Equipment Manufacturer (OEM) authorized dealer, authorized distributor, or authorized reseller for the proposed equipment/system such that the OEM warranty and service/support pass through to the VA customer in totality. All warranty and service associated with the equipment/system shall be in accordance with the OEM terms and conditions. The vendor shall provide new items ONLY; no remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty.

DISCLAIMER AND ADDITIONAL NOTICES:

Responses may be used as research to better understand the market place or for creating a potential future acquisition. Response is strictly voluntary; no reimbursement will be made for any costs associated with providing information in response to this or future information requests.

AT THIS TIME NO SOLICITATION EXISTS. (DO NOT REQUEST A COPY OF THE SOLICITATION).

This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. After a review of the responses received, a solicitation may be published in Federal Business Opportunities. However, responses to this notice will not be considered adequate responses to a solicitation.

No Proprietary, classified, confidential, or sensitive information should be included in your response. The Government reserves the right to use any non-proprietary technical information in any resultant solicitation(s.)

Files

File Type Posted
36C26325Q0665.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular Department of Veterans Affairs VA Caribbean Healthcare System San Juan PR 00921 · NAICS 339112 Veterans Integrated Service Network 8 No set-aside
6695--surgery globus instrument set Department of Veteran's Affairs Oklahoma City Va Health Care System Oklahoma City OK 73104, United States · NAICS 339112 Veterans Integrated Service Network 19 Service-Disabled Veteran-Owned Small Business
J065--Imaging Service & Preventative Maintenance EHCC & MTV Evansville Health Care Center Evanville, Indiana 47715, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside
6525--SEP 2026 Equipment Only Consolidation NAICS 334517 National Acquisition Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors