6515--NX EQ Scanning Systems Ultrasonic Portable (VA-27-00010422)

Closed Pre-Solicitation Posted

Solicitation number
36C10X27Q0004
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Nationwide

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Enterprise Procurement Office is conducting a sources sought notice to identify qualified suppliers of Fujifilm Sonosite brand or equivalent portable ultrasonic scanning systems for delivery to VA medical centers and facilities throughout the United States, with responses due by October 19, 2026, at 12:00 p.m. Eastern Time. The VA anticipates awarding a single Requirements Contract with Firm-Fixed Price orders under FAR 16.503. This is market research only and does not constitute a solicitation for bids or proposals.

The procurement covers 29 contract line items encompassing Sonosite ultrasonic transducers, systems (PX, LX, and ST models), accessories, warranty options, and training services on an agency-wide basis. Salient characteristics include high-resolution imaging at 1280 x 1024 pixels minimum, multiple Doppler modes, 120V and battery power capability, multiple probe types with specific frequency ranges (phased array 1–5 MHz, endocavitary 2–12.5 MHz, linear greater than 12 MHz), needle visualization enhancement, minimum one-year warranty, operator training, and extended service/support plans. Evaluation will assess safety features, design functionality, performance capabilities, HIPAA/GDPR compliance, and ANSI/AAMI ES6061 standards.

NAICS code 334510 (Electromedical and Electrotherapeutic Apparatus Manufacturing) applies, with a small business size standard of 1,250 employees. All respondents must maintain active SAM registration with appropriate NAICS certification; SDVOSB and VOSB respondents must be verified in the SBA database at submission. Responses must include company information, SAM UEI, business size and socioeconomic status, manufacturer/distributor designation, country of origin, evidence of authorized distributor status if applicable, technical literature demonstrating salient characteristic compliance, service plan details, pricing with quantity discounts, and subcontracting opportunities. Submit to Alanna Wilson (Alanna.Wilson@va.gov) and Anthony Zibolski (Anthony.Zibolski@va.gov).

Notice text

1.0 DESCRIPTION

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Enterprise Procurement Office (EPO), formerly the Strategic Acquisition Center (SAC), is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Scanning Systems Ultrasonic Portable.

The EPO in conjunction with VHA is seeking qualified sources capable of supplying the brand name or equal Fujifilm® Sonosite Scanning Systems Ultrasonic Portable machines on an agency-wide basis. VA is contemplating the award of a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contracts, to a supplier of this equipment. Respondents will be required to deliver complete ultrasonic scanning systems to VA medical centers and facilities throughout the United States.

The associated North American Industry Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees.

The FAR Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation. You may access the SAM website at SAM.gov | Home. All respondents must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB respondents must be verified in the SBA database at: https://www.sba.gov/veterans/#vetcert at the time of submission.

Submissions for this Sources Sought Notice shall be submitted by email no later than October 19, 2026, at 12:00pm Eastern Time to the Contract Specialist and Contracting Officer at the following email addresses:

Alanna.Wilson@va.gov

Anthony.Zibolski@va.gov

Email responses shall include the following subject line: Response to Sources Sought Notice 36C10X27Q0004.

This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.

2.0 SCOPE OF WORK

Scanning Systems Ultrasonic Portable are compact devices that use high frequency sound waves for real-time internal body imaging. Point-of-care ultrasound (POCUS) imaging is routinely used by medical clinicians to guide interventional percutaneous procedures such as vascular access, nerve blocks, and therapeutic injections. Ultrasonic scanning systems have an ultrasonic scanner, transducers (frequencies of 2 to 12 MHz are typical for vascular and abdominal scanning, procedure guidance, and nerve blocks), dedicated software, DICOM software for PACS compatibility and image storage, and an image recorder. Most ultrasonic scanners include continuous-wave and pulsed-wave Doppler capabilities (including a spectrum analyzer) for sensing the velocity and location of blood flow; they can be operated in multiple modes, including color flow mapping mode and triplex mode (i.e., simultaneous acquisition and display of 2-D gray-scale, spectral Doppler, and color flow data). Ultrasonic scanning systems usually display images of the vessels in conjunction with spectrum analysis to depict the vessel and its obstructions. Some ultrasonic scanners use a low frequency (typically 2 MHz) Doppler transducer to obtain the blood flow velocity recording in the intracranial arteries. These systems are used for transdermal examinations and diagnosis of diseases, occlusions, and obstructions in the peripheral vascular system, including a profile of the blood-flow velocity in the area under examination. Most of them also include capabilities for small-part examinations.

The following Contract Line Items (CLINs) are being considered:

Contract Line Items

Manufacture

Part Number

Description

0001

Sonosite

L22916

Transducer, L12-3

0002

Sonosite

L23117

Transducer, C10-3

0003

Sonosite

L23119

Transducer, C5-1

0004

Sonosite

L23120

Transducer, L15-4

0005

Sonosite

L23121

Transducer, IC10-3

0006

Sonosite

L23972

Transducer, L19-5

0007

Sonosite

L24087

Transducer, P5-1

0008

Sonosite

L25100

Sonosite PX Ultrasound System

0009

Sonosite

L25110

Sonosite PX Stand

0010

Sonosite

L25200

Printer, B and W Hybrid Graphic, SONY UP-X898MD

0011

Sonosite

L27766

T8-3 ULT-2020 Ultrasound Leakage Tester Kit

0012

Sonosite

L28354

Sonosite LX Ultrasound System

0013

Sonosite

L29076

Sonosite ECG Module

0014

Sonosite

L29465

Transducer, T8-3

12 Months - Standard Coverage Warranty

0015

Sonosite

L29671

Transducer, P11-3

0016

Sonosite

L30229

Transducer, T8-3 POCUS Bundle

-12 Months - Standard Coverage Warranty

0017

Sonosite

L30257

Transducer, L13-6

0018

Sonosite

L31500

Sonosite ST Ultrasound System

0019

Sonosite

L33270

Transducer, UHF46-20 MHz Ultra High-Frequency

-12 Months - Standard Coverage Warranty

0020

Sonosite

P31199

Steep Needle Profiling, Sonosite ST

0021

Sonosite

P31440

Sonosite Voice Assist

-12 Months - Standard Coverage Warranty

0022

Sonosite

P31987

Small Basket

0023

Sonosite

P31988

Large Basket

0024

Sonosite

P32357 - Sonosite PIV Assist

Sonosite PIV Assist

0025

Sonosite

P32441-SVCCON

Point of Sale Warranty Plus (2 years), PX System

0026

Sonosite

P32442-SVCCON

Point of Sale Warranty Plus (2 years), LX System

0027

Sonosite

P32443-SVCCON

Point of Sale Warranty Plus (2 years), ST System

0028

Sonosite

P32444-SVCCON

Point of Sale Warranty Plus (2 years), PX/LX/ST/MT

Transducers (Not applicable for the T8-3 or UHF46x Transducers)

0029

Sonosite

Sonosite Institute for Point-of-Care Ultrasound

Exclusive access to

over 100 hours of education including courses, videos, webinars, quizzes, certificates and additional resources. Accessible via desktop, tablet or phone. (Included)

Respondents should identify a complete solution including associated accessories, as required for full functionality.

The following Salient Characteristics (SCs) are being considered:

CLINs 0001-0013, 0015, 0017, 0020 apply to the following SC 1-9

CLINs 0014, 0016, 0019, 0021 apply to the following SC 10

CLINs 0026-0028 apply to the following SC 12

CLIN 0029 applies to the following SC 11

SC #

SALIENT CHARACTERISTICS

METHOD OF EVALUATION

SC 1

Multiple configurations of the devices

Literature Review

SC 2

Must have High-quality image resolution1280 x 1024 pixels or higher

Literature Review

SC 3

Must have multiple Doppler modes to include color, and continuous Wave

Literature Review

SC 4

Must have 120V and Battery powered capability

Literature Review

SC 5

Must have a Phased Array Probe with a low frequency range of between 1-5 MHz

Literature Review

SC 6

Must have Endocavitary Probe with a frequency range between 2-12.5 MHz

Literature Review

SC 7

Must have Low to Mid Probe with a frequency range of at least 2-12 MHz Curvilinear Probe

Literature Review

SC 8

Must have Linear Probe with a frequency range greater than 12 MHz

Literature Review

SC 9

Must have needle visualization enhancement

Literature Review

SC 10

Must have a minimum one-year warranty

Literature Review

SC 11

Must provide Operator training

Literature Review

SC 12

Must provide Extended Service and Support plan

Literature Review

SC 13

Must be FDA approved

FDA Letter

SC 14

Must have Intraoperative system capable of interfacing with VA Electronic Health Record System

Literature Review

For each product identified in the response (brand name and part number), the response must include descriptive literature demonstrating that the product meets or exceeds the SCs specified above.

The Government's intent is to include all ancillary items necessary to ensure the equipment can function as designed by the OEM and as required. Respondents are encouraged to identify any additional accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. These items must be clearly identified by brand name and part number.

In addition to the above CLINs and salient characteristics, the Government contemplates utilizing the below evaluation subfactors:

Safety

The device will be assessed for patient safety features, including, but not limited to, the following areas:

Infection control

Thermal injuries

Probe maintenance

Battery failure procedures

Design

Design features and functions of the offered device will be evaluated. Areas include but are not limited to the following:

Durability of the system and the probes

Display screens usability

Barcode software to ID patients and physicians

Low-Profile wheelbase to assist getting closer to patient

Cordless charging station

Number of Transducer ports

Simplicity of system design for operator (ergonomics, easy setup, User-friendly software applications, reporting, and touch screen ease of use)

Performance

The device will be evaluated for its ability to perform its intended function. Areas include but are not limited to:

Capabilities to support multiple medical services

Batter run time

Provided Installation

Needle guidance system

Quality/Construction/Training

Extended Warranty

Training

Secure Data encryption HIPPAA/GDPR compliant

Meets ANSI/AAMI ES6061 Electromechanical safety standards

Responses to this Sources Sought Notice shall include the following:

Full name and address of company.

SAM Unique Entity Identifier (UEI).

Business Size and socioeconomic status, if applicable (e.g., SDVOSB, VOSB, WOSB, HUBZone, 8(a)).

Manufacturer or Distributor:

If distributor, provide the full name, business size and address of the manufacturer.

If distributor, provide evidence that your firm is currently an authorized distributor for the manufacturer of the products proposed, e.g. an authorized distributor letter with current date certified by the OEM.

Country of Origin designation for all products proposed.

Describe the firm s ability to provide uninterrupted supply of products on a national scale.

Technical literature clearly demonstrating that the proposed product(s) meets the identified salient characteristics identifying the page number(s) where each requirement is met.

Does respondent offer an annual service plan, Yes or No?

If Yes:

Describe what the plan covers?

Identify whether the plan covers software updates, parts repair/replacement, or both

Provide literature or other documentation describing the service plan.

Identify whether service is provided by the OEM or a subcontractor.

Identify any additional product, accessory, service, or configuration that may be necessary or beneficial to the functionality of the contemplated system. Include the applicable brand name and part number.

Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what order quantity the Government should expect tiered price reductions, if any.

NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.

Does your firm anticipate any subcontracting opportunities for this requirement? If yes, identify the type and approximate scope of work that could be subcontracted.

Identify any federal contract vehicles held by your firm through which your firm can provide this equipment.

Are there any further standards or criteria VA should consider in a procurement action for this equipment?

Are the Government s specifications unduly restrictive? If yes, identify the specific requirement(s) considered unduly restrictive and provide supporting rationale and recommended alternative language.

Any additional information the Government should know prior to issuing a solicitation.

Describe any minimum order quantities, geographic limitations, delivery constraints, lead times, or other limitations that could affect the firm's ability to support the requirement on a nationwide basis.

Files

File Type Posted
36C10X27Q0004.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
6515--Notice of Intent to Award Sole Source - TEE PROBE TRANSDUCER NAICS 334510 Veterans Integrated Service Network 2 No set-aside
6530--NX EQ Environmental Disinfection Systems Pulsed Xenon UV Light (VA-27-00012571) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick No set-aside
Philips EPIQ CVx Ultrasound System Repair Palo Alto, California 94304, United States · NAICS 339112 Veterans Integrated Service Network 21 No set-aside
J065--Philips Imaging Equipment Service Maintenance NYH NAICS 811210 Veterans Integrated Service Network 2 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide, United States · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors