6515--Equipment, Quality Assurance (QA) Device - RadOnc, Ann Arbor

Closed Special Notice Posted

Solicitation number
36C25026Q0692
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Integrated Service Network 10 issued a notice of intent to sole source a Daily QA 4 Pro System and accessories to Sun Nuclear Corp, with response deadline June 29, 2026 at 6:00 PM Eastern Time and anticipated award no later than July 19, 2026. The Ann Arbor Veterans Affairs Medical Center is procuring quality assurance equipment for radiation oncology operations under solicitation number 36C25026Q0692, a firm-fixed-price contract under simplified acquisition threshold authority. The QA 4 Pro System will perform daily quality assurance testing on linear accelerators prior to patient treatment, verifying beam output constancy, imaging accuracy, positioning accuracy, and overall machine functionality to ensure safe radiation therapy delivery. The procurement includes two units of the Daily QA 4 Pro system, two DQA adapter plates for 6DOF couches, and one customer web-based training package. The VA determined Sun Nuclear Corp is the only responsible source meeting requirements based on market research identifying their product as the sole domestic commercial option. Interested parties may submit documentation demonstrating alternative capabilities; responses must be submitted via email to Contracting Officer Percy Johnson at percy.johnson2@va.gov with subject line "RESPONSE TO SOLE SOURCE NOTICE 36C25026Q0692." Respondents must be registered in SAM and provide an authorized distributor letter if not the original manufacturer. NAICS 334519 (other measuring and controlling device manufacturing), PSC 6515, small business size standard 600 employees.

Notice text

DESCRIPTION

NOTICE OF INTENT TO SOLE SOURCE

This notice is in accordance with (IAW) Revolutionary FAR Overhaul (RFO) 5.101.

The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 10, hereby provides notice of its intent to award a sole source, firm-fixed price contract for the product/service listed below to

Sun Nuclear Corp. The contract is expected to be awarded under authority of RFO 6.103-1, Only one responsible source and no other supplies or services will satisfy agency requirements.

The contract is expected to be awarded under the authority of RFO 12.102(a) for acquisitions valued at or below the simplified acquisition threshold (SAT), document the decision that only one source is available and the basis for the decision. A Sole Source Justification for Other Than Full and Open Competition has been prepared. The anticipated award date is no later than 07-19-2026. The contractor will provide the product listed below

This is a sole source requirement. The Ann Arbor VAMC, 2215 Fuller Rd, Ann Arbor, MI 48105, and Network Contracting Office 10, 2780 Airport Dr., Suite 340, Columbus, OH 43219 is requesting to purchase the QA 4 Pro System and accessories.

The Daily QA 4 Pro will be utilized to perform required daily quality assurance testing on linear accelerators prior to patient treatment delivery to ensure machines are operating safely and within established clinical tolerances. The systems will provide comprehensive verification of beam output constancy, imaging accuracy, positioning accuracy, and overall machine functionality to support safe and effective radiation therapy treatments of Veterans. This acquisition will support uninterrupted clinical operations, regulatory compliance, and continued delivery of high-quality patient care within Radiation Oncology.

The NAICS code is 334519 with a small business size standard of 600 employees. The VA intends to solicit and negotiate with Sun Nuclear Corp, located at 425 PINEDA CT STE A, Melbourne, FL 32940.

Market research was able to identify domestic commercial products that can meet this requirement. Research shows that the QA 4 Pro System is manufactured by Sun Nuclear Corp, and the items can be purchased directly form them.

DAILY QA 4 PRO

2

EA

DQA4 ADAPTER PLATE FOR 6DOF COUCHES

2

EA

CUSTOMER WEB-BASED TRAINING

1

EA

Specifications:

Salient Characteristic: Sun Nuclear Daily QA 4 Pro

The Sun Nuclear Daily QA 4 Pro is a comprehensive, integrated daily quality assurance system designed for radiation therapy linear accelerator verification. The system shall provide a single, indexed, all-in-one platform capable of performing daily dosimetric, geometric, and imaging quality assurance checks in a single setup without the need for multiple phantoms or separate measurement devices. It shall include high-resolution detector arrays utilizing diode and ion chamber technology to support measurement of output constancy, beam flatness, symmetry, field size verification, dose per pulse, and beam profile characteristics across clinically relevant field sizes. The system shall be capable of performing integrated Winston-Lutz testing for verification of radiation isocenter accuracy and geometric alignment suitable for SRS/SBRT applications. It shall also support comprehensive imaging system quality assurance for kV, MV and cone-beam CT imaging systems within the same device workflow. The device shall allow for automated data acquisition, analysis, and trend reporting, with compatibility for electronic QA management systems such as SunCHECK or equivalent platforms, to ensure documentation, traceability, and compliance with AAPM TG-142 recommendations. The system shall be designed to improve workflow efficiency by reducing setup time, minimizing room entries, and enhancing reproducibility through indexed positioning and standardized daily QA procedures.

THIS NOTICE OF INTENT IS NOT A SOLICITATION OR REQUEST FOR COMPETITIVE QUOTES

However, interested parties may identify their interest and capability to respond to this requirement and may submit a bid, proposal, or quotation (as appropriate) that the agency shall consider within the given closing/due date of this notice.

A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government. Information received will normally be considered solely for determining whether to conduct a competitive procurement. The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses will be considered. All responses from responsible sources will be fully considered. As a result of analyzing responses to this notice of intent, the Government shall determine if a solicitation will be issued. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award and must submit a current authorized distributor letter from the manufacturer.

Interested parties are encouraged to furnish information by email only with RESPONSE TO SOLE SOURCE NOTICE 36C25026Q0692 in the subject line. All documents submitted will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Percy Johnson, contracting specialist, by email at percy.johnson2@va.gov NO LATER THAN the given closing date and time on this notice. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities like an authorized distributor/reseller letter from their source of supply if not a manufacturer that will demonstrate the ability to support this requirement.

Files

File Type Posted
36C25026Q0692.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
FRESNO- Radiology X-Ray System PM Services NAICS 811210 Veterans Integrated Service Network 21 No set-aside
6515 - Intent to Sole Source - Siemens Skyra Coldhead RDE-412L4 (11472997 San Francisco, California 94121, United States · NAICS 339112 Veterans Integrated Service Network 21 No set-aside
H365--460-27-1-132-0001 | SPE 49273 | VISN 4 Radiation Safety Officer (RSO) | NCO 4 Services 3 (VA-27-00003148) 9 VA Medical Facilities In the NCO 4 Service Area · NAICS 541380 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business
J065--FY27 (BASE 4) RaySearch America RayStation Treatment Planning System Service Contract NAICS 541519 Veterans Integrated Service Network 2 No set-aside
J065--Philips Imaging Equipment Full-services for Bronx NAICS 811210 Veterans Integrated Service Network 2 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors