6515--36C242-25-AP-3692 | 528-25-3-8085-0085 Microwave Ablation System (VA-25-00090638)

Closed Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
36C24225Q0828
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Albany Vamc 113 Holland Ave Albany, New York 12208, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is seeking to procure a Microwave Ablation System for the Albany VA Medical Center's Interventional Radiology department. This procurement represents a technology upgrade from radiofrequency ablation to microwave ablation technology, requiring a standalone unit operating at 2.45 GHz frequency with 140-160W microwave power amplifiers. The system must include specific technical requirements such as two fully integrated peristaltic pumps, a 15.6-inch foldable touchscreen that operates with gloved fingers and sterile drapes, and dual probe support with independent channel controls. The unit must provide output power ranging from 0-90W for single channel operation and 0-160W for two-channel operation, with additional features including tract ablation capabilities, needle lock probe migration solution, and support for remote temperature probes. Responses to this Sources Sought Notice are due by July 16, 2025, at 12:00 pm Eastern Time under solicitation number 36C24225Q0828, with Corey Swinton serving as the contracting officer.

This procurement does not specify any set-aside designation and falls under NAICS code 334517 for Irradiation Apparatus Manufacturing and PSC code 6515 for Medical and Surgical Instruments, Equipment, and Supplies. The solicitation does not identify any incumbent contractors or provide specific award values or budget ranges for this equipment purchase. The procurement focuses on acquiring a single microwave ablation unit that will be installed at the Albany VAMC facility located at 113 Holland Avenue in Albany, New York. The device specifications indicate it should accommodate coolant capacity of 1000mL or greater using sterile water or 0.9% saline solution, and the system is classified as non-critical RME (Reusable Medical Equipment) with plastic housing construction. The solicitation will remain archived for 99 days following the response deadline, and interested parties can contact the contracting officer at Corey.Swinton@va.gov for additional information.

Notice text

2

1

Statement of Work

Microwave Ablation unit

For Interventional Radiology Albany VA Medical Center

6/11/2025

GENERAL INFORMATION

The general scope of this procurement is to purchase a Microwave Ablation unit

Equipment Purchase

SCOPE

Technology upgrade; replacing radiofrequency ablation with microwave ablation technology.

REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS

Common Nomenclature: Microwave Ablation

Kind of material: Plastic housing, Single stand along unit, non-critical RME.

Electrical Data: 140 -160W microwave power amplifiers operating at 2.45 GHz

Dimensions, size, capacity: N/A

Principles of operation: Microwave energy refers to a specific subset of the radio frequency (RF) spectrum operating between 300 MHz to 300 GHz. This device uses probes to direct microwave pulses to energize targeted tissues to treat them, especially cancer cells. The ablation unit to be procured in this requirement should have an output power of 0-80W for a single channel and 0-160W for a 2 channel.

Technical Requirements:

Component

Specification

Pumps

Two (2) fully integrated peristaltic pumps

Touchscreen Monitor

15.6-inch foldable touchscreen

Swivels

180-degrees CW/CCW

Operable with gloved fingers

Yes

Operable with sterile drape

Yes

Input / Output

One (1) USB port and one (1) Ethernet port

Tract Ablation

Cauterizes needle tract

Needle Lock

Probe migration solution

Coolant

1000mL or greater

Sterile water or 0.9% saline (user provided)

IntelliBlate Microwave Ablation System Instructions for Use 19

Performance Characteristics

MWA Generator Frequency

2.45 GHz ± 50 MHz

Applied Part Type

Type BF Dual probe support and independent channel controls. Two remote temperature probe support.

Output power (tip referenced)

Single Channel: 0-90W

Two (2) Channel:

0-80W (each), 0-160W (linked)

Microwave Output Power Accuracy

Within 10 seconds of activation of output energy on the touchscreen

Power (tip referenced)

Files

File Type Posted
36C24225Q0828.docx DOCX document

Notice history

Notice Type Posted
6515--36C242-25-AP-3692 | 528-25-3-8085-0085 Microwave Ablation System Latest solicitation Solicitation
6515--36C242-25-AP-3692 | 528-25-3-8085-0085 Microwave Ablation System Pre-Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Q525--LASER SERVICES - BUFFALO UROLOGY Holmium (30 and 80 Watt) Lasers CO2 Laser Lithotripsy (ESWL) Laser Department of Veterans Affairs Va Wny Healthcare System Buffalo, New York 14215, United States · NAICS 621999 Veterans Integrated Service Network 2 No set-aside
6515--Medtronic IPC Instruments Michael E. DeBakey VA Medical Center Houston, TX 77030, United States · NAICS 339112 Veterans Integrated Service Network 16 No set-aside
Neuro Micro Instruments Houston, Texas 77030, United States · NAICS 339112 Veterans Integrated Service Network 16 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors