648-24-103 Replace Sewer Riser
Closed Solicitation Posted
- Solicitation number
- P00001
- Agency
- Veterans Integrated Service Network 20 Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Portland, Oregon 97207, United States
- Points of contact
-
- Madeline Small madeline.small@va.gov (971) 373-3080
Notice details come from SAM.gov. Updated .
About this opportunity
This federal contract opportunity, Solicitation Number P00001, is issued by the Department of Veterans Affairs (VA) Veterans Health Administration, Veterans Integrated Service Network 20. The VA is seeking a contractor to provide labor, materials, equipment, and services required to coordinate and develop an effective sewer drain bypass, demolish and remove existing 6-inch sewer drain and 4-inch drain line, and furnish and install new 6-inch sewer drain, 4-inch corrosion-resistant cast iron drain line, and necessary bracing at the Portland VA Medical Center. The contractor will also be required to perform appropriate testing to verify the work meets acceptable standards.
The contract is set aside for small businesses under a Total Small Business set-aside. The solicitation has a due date of September 9, 2024, and no questions were submitted as a result of the pre-bid site visit held on September 4, 2024. The place of performance is located in Portland, OR 97207. No incumbent contractor information is provided, and the contract value is not specified.
Notice text
Portland VAMC seeks a contractor to provide all labor, materials, equipment, supervision, and all other resources necessary to perform services required for the following work:
- Coordination and development of effective sewer drain bypass to allow work to be completed on existing 6” sewer drain. Core drilling is permittable.
- The demolition and removal of existing 6” Sewer Drain and Y-fittings from the second floor through the fifth floor and existing 4” drain line located on the basement level of the facility (B2 ceiling space).
- Furnishing and Installation of 6” Sewer Drain and Y-fittings from the second floor through the fifth floor and 4” corrosion resistant cast iron drain line and Y-fittings located on the basement level (B2 ceiling space).
- Add bracing to newly installed pipe to provide support for axial and lateral deflection or movement.
- Perform appropriate testing to verify acceptable standard of work.
Attachments
| File | Type | Posted |
|---|---|---|
| Attachment 2- Sign in sheet.pdf | ||
| Attachment 1- Contractor Price Breakdown.xlsx | XLSX spreadsheet | |
| 36C26024Q0844 0001.docx | DOCX document |