4520--Hot Water Heater
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25626Q0922
- Agency
-
Veterans Integrated Service Network 16
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 333414 Heating Equipment (except Warm Air Furnaces) Manufacturing
- PSC
- 4520 Space And Water Heating Equipment
- Place of performance
- Michael E. DeBakey VA Medical Center 2002 Holcomb Blvd 77030, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Integrated Service Network 16 is conducting a sources sought and request for information to establish procurement strategy for two DHT STV-90030-10D-CU vertical steam-to-water heaters, with responses due June 18, 2026 at 11:00 AM Central Time. The RFI is preliminary and non-binding; no formal solicitation currently exists, and the government intends to post a solicitation shortly thereafter.
Place of performance is Michael E. DeBakey VA Medical Center, Houston, Texas. The requirement includes factory-supplied components (10-inch double-wall copper tube bundles, modulating steam control valves, condensate drain assemblies) and field-supplied materials (1-inch T&P relief valve rated 150 psi/210F with 730,000 BTU/hr capacity, piping, valves, fittings, insulation, and electrical wiring). Installation scope encompasses site verification, mechanical installation of domestic water and steam piping with isolation valves and strainers, electrical and controls integration with the Building Management System via Metasys Johnson Control and BACNET-compatible interfaces, and startup commissioning with low-temperature (115F) and high-temperature (145F) alarm thresholds. The contractor must provide comprehensive operator training for up to 10 employees and assign a dedicated project manager responsible for schedule management, site coordination, documentation, and closeout. A one-year installation warranty covering labor, workmanship, and installation-related defects is required.
NAICS 333414 applies with a 500-employee small business size standard; PSC 4520. Respondents must identify business size classification, small business concern status (SB, SDVOSB, VOSB, HUBZone, 8A), compliance with the Non-Manufacturer Rule, authorized distributor status with OEM parts access and manufacturer authorization letter, and availability under GWAC, GSA Schedule, or IDIQ vehicles. Estimated market pricing must be provided. Submit responses to Tabitha Crosby at tabitha.crosby@va.gov in Microsoft Word format with subject line "RFI 36C25626Q0922 - Hot Water Heaters."
Notice text
This is a source sought notice/request for information only. The responses to this posting will be
used to establish the procurement strategy, for example, set-aside, sole source, unrestricted for
a solicitation that VA intends to post in the near future. Please review the attached document(s)
for more details on this requirement.
See attached document(s):
-36C25626Q0922 - Request for Information (RFI)
-Statement of Works (SOW)
DISCLAIMER: THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS SYNOPSIS IS NOT A REQUEST
FOR QUOTE, PROPOSAL, OR BID. This notice is not a solicitation as defined by FAR 2.101, therefore it
shall not be construed as a commitment by the government to enter into a contract, nor does it restrict the
government to an acquisition approach. All information contained in this Request for Information (RFI) is
preliminary as well as subject to amendment and is in no way binding on the government. Information
submitted in response to this notice is voluntary; the government will not pay for information requested
nor will it compensate any respondent for any cost incurred in developing information provided to the
government. The government is requesting that restrictive or proprietary markings not be used in
response to this notice. If a solicitation is released, it will be synopsized in the Federal Contract
Opportunities website or General Services Administration (GSA). It is the responsibility of the interested
parties to monitor these sites for additional information pertaining to this RFI.
1. Title: Hot Water Heaters
2. Purpose: The purpose of this RFI is to identify potential sources that will aid in defining the
procurement strategy for example, set-aside, sole source, or unrestricted for a solicitation the VA intends
on issuing shortly as follows:
The Michael E. DeBakey VA Medical Center (MEDVAMC) located in Houston, Texas has a requirement
for two (2) DHT STV-90030-10D-CU Vertical Steam-to-Water Heater, including steam, condensate, domestic water, controls, and safety devices.
Item #
Description/Part Number* Products
QTY
1.
DHT STV-90030-10D-CU ST SERIES VERTICAL ASSY, 10" DOUBLE WALL COPPER
2 EA
ST-90025-3-10 STEAM VALVE ASSY, 3" VALVE, 10" UNIT
- ST-90024-75-JD8 CONDENSATE DRAIN ASSEMBLY - CAST IRON - 2" - 75JD8
- 22007-240X-6 T&P RELIEF VALVE PACKAGE: T&P RELIEF VALVE N240X-6 1F X 1F
- SR-90026-3 STEAM INLET PIPING ASSEMBLY - 3"
2.
START UP, COMMISSIONING, & OWNER TRAINING 1
1 EA
Warranty & Installation
3.
The contractor shall provide a standard installation warranty covering workmanship, labor, and installation related defects.
. One (1) year from the date of substantial completion
or
One (1) year from the date of startup
(Whichever occurs later, unless otherwise specified by contract.)
Whichever occurs later, unless otherwise specified by contract.)
All labor and workmanship associated with the installation
The anticipated Small Business Administration (SBA) size standard for the North American Industry
Classification System (NAICS) code is 333414 Space and Water Heating Equipment Manufacturing and a standard size of 500 employees. Product Supply Code (PSC) 4520 Heating Equipment (except Warm Air Furnaces) Manufacturing
3. Responses Requested: The following questions must be answered in response to this RFI. Answers
that are not provided shall be considered non-responsive to the RFI:
a. Are the requested items manufactured by a small or large business?
Vendor must attach documentation of this information to be viewed by the government to be
considered as part of Market Research and responsiveness to this Sources Sought notice:
b. Is the potential vendor in compliance with the Non-Manufacturer Rule (NMR)?
Vendor must attach documentation of this to be viewed by the government to be considered as
part of the Market Research and responsiveness to this Sources Sought notice:
c. Is the Vendor an authorized distributor with access to Original Equipment Manufacturer
(OEM) parts which may be required in completion of this requirement? The VA does not
accept grey market items; therefore, the Vendor must attach an authorized distribution
letter as an approved and authorized vendor on OEM letterhead by the manufacturer as
evidence of proof to be viewed by the government to be considered as part of the Market
Research and responsiveness to this Sources Sought notice.
d. Name of potential Contractor that possesses the capability to fulfill this requirement.
Contractors shall also provide the following:
Point(s) of contact name: ______________________________________
Address: ___________________________________________________
Telephone number: ___________________________________________
Email address: _______________________________________________
Company's business size: _______________________________________
UEI #: ______________________________
CAGE Code: _______________________________
e. Is your company considered a small business concern, SB, SDVOSB, VOSB, HUBZone, or
8A concern, with the requisite 339112 NAICS code?
Please provide proof of qualifications.
f. Is your company available under any Government Wide Agency Contract (GWAC), GSA
Schedule, Federal Supply Schedule (FSS), Indefinite Delivery Indefinite Quantity (IDIQ), and/or
Blanket Purchase Agreement (BPA)?
If so, please identify the contract number for the government to review as part of this Market
Research.
4. Opportunity/Market Pricing: MEDVAMC is seeking information from potential vendors on
their ability to provide the required items/equipment. THIS IS A SOURCES SOUGHT
REQUEST FOR INFORMATION (RFI) ONLY. Small Business concerns are encouraged to
provide responses to this RFI in order to assist the MEDVAMC in determining potential levels of
competition and general market pricing available in the industry. Vendors are requested to
submit estimated market research pricing along with their responses to the above. The
estimated pricing will be considered when determining the procurement strategy for the
forthcoming solicitation. Contractor shall provide answers to all questions requested and shall
possess the ability to provide all requirements and objectives per the DRAFT STATEMENT OF
OBJECTIVES.
5. RFI responses are due by 11:00 am Central Standard Time on June 18, 2026; size is
limited to 8.5 x 11 inches, 12-point font, with 1-inch margins in Microsoft Word format via email
to tabitha.crosby@va.gov
The subject line shall read: RFI 36C25626Q0922 Hot Water Heaters.
NO SOLICITATION EXISTS AT THIS TIME.
There is no page limitation on subparagraphs 3(a) - 3(g). Please provide the information you
deem relevant in order to respond to the specific inquiries of the RFI. Information provided will
be used solely by MEDVAMC as Market Research and will not be released outside of the
MEDVAMC Purchasing and Contracting Team.
6. Contact Information:
Tabitha Crosby
tabitha.crosby@va.gov
See attached document: Statement of Objectives Hot Water Heaters
Files
| File | Type | Posted |
|---|---|---|
| 36C25626Q0922.docx | DOCX document | |
| DRAFT SOW Water Heater.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 657-27-107JC, Replace Select Hot Water Heating System | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| Amendment CTX Steam Humidifier | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business | |
| 6515--Sterilizer | Veterans Integrated Service Network 17 | No set-aside | |
| N045--Boiler 3 Oxygen Analyzer and Steam Flow Meter | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business | |
| H265--BD Alaris Infusion Pumps Preventative Maintenance Services | Veterans Integrated Service Network 16 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity