182d Airlift Wing, Peoria Illinois, Repair Fire Alarm System

Closed Pre-Solicitation Posted

Solicitation number
A046565
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
561210 Facilities Support Services
Place of performance
Illinois 61607, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The 182nd Airlift Wing, Illinois Air National Guard, intends to solicit and award a contract to repair the base fire alarm system, with sources sought responses due July 16, 2026 by 12:00 p.m. CST. The procurement is set aside for Total Small Business and carries an anticipated contract value between $500,000 and $1,000,000.

Work is performed at the 182nd Airlift Wing in Peoria, Illinois, spanning 27 buildings across the base including Security Forces, Engine Shop, Avionics, Base Supply, Munitions, Aerial Port, Civil Engineer, Fire Department, and other facilities. The scope encompasses removal and replacement of existing fire alarm control panels, installation of ethernet-compatible communications packages compatible with COINv3 standards, replacement of existing initiating devices with addressable devices, integration of the existing Mass Notification Warning System, and installation and programming of all units with central station reporting to buildings B541 and B636. Select locations require integration of Very Early Warning Smoke Detection systems, communications vault suppression/detection systems, and kitchen detection and suppression notification systems. Two contract line items address installation of new TrueSite Workstations with Windows 11 platforms, COINv3-compatible graphics, and 30-minute battery backup power supplies at buildings B636 and B541.

All materials, equipment, and workstations must be manufactured by Simplex to ensure compatibility with recently installed systems. Respondents must provide current, official documentation from Simplex/Johnson Controls verifying status as an Authorized Simplex Dealer/Partner. Work must comply with UFC 3-600-01 and ANG ETL 15-01-03 standards. The contractor must submit material submittals within 10 business days of award and provide one-year written guarantees for defect repair and replacement from substantial completion. All employees must complete AT Level I awareness training within 30 calendar days of contract start.

Points of contact are SSgt Emily Scully (emily.scully.1@us.af.mil) and 1st Lt Nicholas Marzinzik (nicholas.marzinzik@us.af.mil).

Notice text

Repair Base Fire Alarm System

Category: Y –Construction of Structures and Facilities—Potential Sources Sought

Date Published: July 9, 2026

Contracting Office: USPFO for Illinois National Guard, 182nd Airlift Wing, Mission Support Contracting, 2416 S. Falcon Blvd, Peoria, IL 61607

Points of Contact:

  • SSgt Emily Scully: emily.scully.1@us.af.mil
  • 1st Lt Nicholas Marzinzik: nicholas.marzinzik@us.af.mil

Subject Line for Responses: Sources Sought Repair Base Fire Alarm System

Synopsis: REPAIR BASE FIRE ALARM SYSTEM sources sought.

The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for PLANNING PURPOSES ONLY. All interested parties should respond. The 182d Airlift Wing of the Illinois Air National Guard, Illinois intends to issue a solicitation and award of a contract to “Repair Base Fire Alarm System”.

The magnitude of this project is Between $500,000 and $1,000,000. All interested concerns will provide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 16 July 2026 12:00P.M. CST.

This notification, which shall not exceed five typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Response Form and (3) A listing of relevant projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor. (4) A brief outline of resources, subcontractors, and key personnel and personnel certified by Simplex to program, test, and service the specific Simplex model that would be used to accomplish the contract. (5) Provide current, official documentation from Simplex/Johnson Controls proving your firm is an Authorized Simplex Dealer/Partner capable of purchasing and installing OEM parts. In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted.

Information shall be provided via email to: emily.scully.1@us.af.mil and nicholas.markzinzik@us.af.mil Include the following in the subject line "Sources Sought Repair Base Fire Alarm System". No facsimile responses will be honored.

Attachment 1: SOW_Repair Base Fire Alarm System (2)

Attachment 2: Sources Sought Information Response Form

                                                                            

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
SACN Replace Fire Alarms and Intrusions Systems United States · NAICS 238210 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors