182d Airlift Wing Peoria, Illinois Repair Base Fire Alarm System
Closed Pre-Solicitation Posted
- Solicitation number
- A046027
- Agency
-
Illinois National Guard
Army National Guard, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Peoria, Illinois 61607, United States
- Points of contact
-
- 1st Lt Nicholas Marzinzik nicholas.marzinzik@us.af.mil (309) 633-6239
- SSgt Emily Scully emily.scully.1@us.af.mil (309) 633-5204
Notice details come from SAM.gov. Updated .
About this opportunity
The 182d Airlift Wing, Illinois Air National Guard, intends to solicit and award a contract to repair the base fire alarm system at Peoria, Illinois, with a sources-sought response deadline of July 6, 2026 at 3:00 p.m. CST. This procurement is set aside for small business.
The anticipated award value ranges between $500,000 and $1,000,000. Work is performed at the 182d Airlift Wing in Peoria, Illinois, and spans 27 contract line items across multiple base buildings including the CERFP, Security Forces, Engine Shop, Avionics, AGE, POL Complex, Base Supply, Munitions, Aerial Port, Civil Engineer, Headquarters, Recruiting, Vehicle Maintenance, Fire Department, Lift Station, Pump House, Combat Communications facilities, Flight Operations, Emergency Management, and Hazmart.
The scope includes removing and replacing existing fire alarm control panels per UFC 3-600-01 and ANG ETL 15-01-03 standards; upgrading communication devices from fiber to COINv3 ethernet-compatible units; replacing initiating devices with addressable units; and upgrading TrueSite Workstations with new COINv3-compatible units featuring Windows 11 platform. All fire alarm panels and workstations must be manufactured by Simplex. Two TSW installations at central stations require ethernet communications packages, new graphics with base maps and building numbers, and minimum 30-minute battery backup power supplies. Material submittals are due within 10 business days of award; contractor employees must complete AT Level I training within 30 calendar days. A one-year written guarantee covering defective materials and workmanship is required.
Interested small businesses must submit positive intent to bid as prime contractor, completed source sought response form, and a listing of comparable projects completed in the past three years. If adequate small business competition is unavailable, the requirement may be advertised as unrestricted. Contact SSgt Emily Scully (emily.scully.1@us.af.mil) or 1st Lt Nicholas Marzinzik (nicholas.marzinzik@us.af.mil).
Notice text
Repair Base Fire Alarm System
Category: Y –Construction of Structures and Facilities—Potential Sources Sought
Date Published: June 25, 2026
Contracting Office: USPFO for Illinois National Guard, 182nd Airlift Wing, Mission Support Contracting, 2416 S. Falcon Blvd, Peoria, IL 61607
Points of Contact:
- SSgt Emily Scully: emily.scully.1@us.af.mil
- 1st Lt Nicholas Marzinzik: nicholas.marzinzik@us.af.mil
Subject Line for Responses: Sources Sought Repair Base Fire Alarm System
Synopsis: REPAIR BASE FIRE ALARM SYSTEM sources sought.
The purpose of this synopsis is to gain knowledge of potential sources for this project including interested
Small Business sources. This notice is for PLANNING PURPOSES ONLY. All interested parties should respond. The 182d Airlift Wing of the Illinois Air National Guard, Illinois intends to issue a solicitation and award of a contract to “Repair Base Fire Alarm System”.
The magnitude of this project is Between $500,000 and $1,000,000. All interested concerns willprovide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 6 July 2026 3:00P.M. CST.
This notification, which shall not exceed five typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Response Form and (3) A listing of projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor. (4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract. In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted.
Information shall be provided via email to: emily.scully.1@us.af.mil and nicholas.markzinzik@us.af.mil Include the following in the subject line "Sources Sought Repair Base Fire Alarm System". No facsimile responses will be honored.
Attachment 1: SOW_Repair Base Fire Alarm System (2)
Attachment 2: Sources Sought Information Response Form
Files
| File | Type | Posted |
|---|---|---|
| SOW_Repair Base Fire Alarm System (2).pdf | ||
| Sources Sought Information Response Form.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| SACN Replace Fire Alarms and Intrusions Systems | — | Total Small Business | |
| Repair Building Systems (Peoria, IL) | Agricultural Research Service | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity