127EAX21Q0079 Rucker Solar Panel Project

Closed Solicitation Posted

Solicitation number
127EAX21Q0079
Agency
Forest Service Department of Agriculture
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
237130 Power and Communication Line and Related Structures Construction
PSC
S112 Utilities- Electric
Place of performance
Douglas, Arizona 85607, United States

Notice details come from SAM.gov. Updated .

Notice text

USDA Forest Service has a requirement for the addition of a lithium‐iron‐phosphate based battery system, augmented with photovoltaics, to the existing 3‐phase (208/120v) generator‐powered electrical system at Rucker Barracks which will result in a substantial reduction of existing generator run‐time. A limited budget requires tradeoffs be identified primarily between battery versus photovoltaic capacity. The goal is to reduce generator starts, and the personnel time required to operate and maintain the generator and fuel system for the Rucker Barracks.
The Contractor shall provide design, cost estimates, installation of and all necessary components for a reliable battery + inverter + photovoltaic based 208/120v electric power subsystem for the Barracks building’s existing internal wiring system for a level of autonomy from the site’s existing propane fueled electric generator. Target performance from the battery + inverter system is 48 hours of autonomy using nominal battery capacity, with extended autonomy duration commensurate with nominal size of photovoltaic subsystem, whose maximum capacity shall be limited by total funding but in any case,
shall be no less than 2,800 nominal watts. The Barracks building is approximately 3900 square feet and can house up to 14 people at one time. The Barracks building has a modern standing seam metal roof with excellent south facing exposure for photovoltaic panels.
A set of batteries, inverters, and photovoltaic panel array with charge controller can operate as a storage intermediate between the genset power, photovoltaics and the Barracks loads. When battery power runs low the generator can be manually started, charging the batteries, and via a manual transfer switch concurrently power the barracks. When occupancy is low or of short duration the battery and PV system can operate with no generator run time.

Attachments

Files attached to this notice, newest first
File Type Posted
Amendment2 Q and As.pdf PDF
Amendment1 Q and As.pdf PDF
Amendment1_StatementofObjectives.pdf PDF
Executed Solicitation_127EAX21Q0079.pdf PDF

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity