ZME-1800750-DRAWING-FINAL.pdf
PDF 3 MB Posted
- Attached to
- Replace AHU6-10 and Hydronic Piping at the Memphis ARTCC located at 3229 Democrat Road, Memphis, TN
- Solicitation number
- 697DCK-23-R-00484
About this file
This document contains drawings and specifications for replacing the air handling units and hydronic piping at the Memphis Air Route Traffic Control Center. The solicitation seeks to replace ten air handling units, identified as AHU6 through AHU10, and update the hydronic piping system. The drawings depict the existing and proposed layouts of the air handling equipment, control diagrams, and mechanical, electrical and controls plans. Technical details covered include temperature and humidity sensor points, air handling unit start/stop functions, system status codes, operating parameters, alarms, and control sequences. Offerors should provide designs and construction services to remove the existing air handling units and piping and install new equipment and controls per the specifications. The solicitation number is 697DCK-23-R-00484 and was issued by the Department of Transportation Federal Aviation Administration for work at their Memphis ARTCC facility located at 3229 Democrat Road in Memphis, Tennessee.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
POINT DESCRIPTION NOTES
D
EV
IC
E
CO
D
E
S U
PE
R
VI
SE
D W
IR
IN
G
A N
AL
O
G I
N
PU
T
D
IG
IT
AL
I N
PU
T
A D
D R
ES
SA
BL
E
IN
PU
T
A
CC
U M
U
LA
TO
R
I N
PU
T
A N
AL
O
G O
U
TP
U T
S
TA
TE
D
IG
IT
AL
O U
TP
U
T
S
TA
TE
D
IG
IT
AL
O U
TP
U
T
A D
D R
ES
SA
BL
E
O U
TP
U
T
F
AI
L O
N /O
PE
N
F
AI
L O
FF
/C
LO
SE
D
L
AS
T
CO
M M
AN
D
S
TA
TE
L O
CA
L
D
EF
AU
LT
N
ET
W O
R K
PO
IN
T
C
AL
CU
LA
TE
D
P O
IN
T
M
AI
N
TE
N
AN
CE
A
LA
R
M
C R
IT
IC
AL
A
LA
R
M
P R
O G
R
AM
S
TA
RT
/S
TO
P
O
PT
IM
U
M S
TA
R
T/
ST
O P
M O
R N
IN
G
W
AR
M /C
O O
L
U N
O
CC
U
PI
ED
S
ET
PO
IN
T
D
EM
AN
D
L
IM
IT
D U
TY
C
YC
LE
E N
TH
AL
PY
E
CO
N
O M
IZ
ER
D
IR
EC
T
D
IG
IT
AL
C O
N
TR
O L
S
ET
P O
IN
T
AD
JU
ST
M
EN
T
T O
TA
LI
ZE
R
R U
N T
IM
E
L
IG
H
TI
N G
C O
N
TR
O L
T
EN
AN
T
BI
LL
IN
G
A
LA
R M
I N
ST
R
U
CT
IO
N
S
M
AI
N
TE
N
AN
CE
W
O R
K O
R D
ER
A
LA
R M
L
IM
IT
S
S O
FT
W
AR
E
IN
TE
R
LO
CK
S
-D
G R
AP
H
IC
S
-D
G R
AP
H
IC
S
F
LO
O R
P
LA
N
P O
IN
T
LI
ST
L O
W L
IM
IT
H
IG
H L
IM
IT
Temp Sensor 1-10 (Typical of 10 Sensors)
TS ● ●
Humidity Sensor 1-10 (Typical of 10 Sensors)
HS ● ●
TYPICAL AHU (1-10,12)
Supply Fan Strt/Stop
SS ● ●
Supply Fan Status
CI ● ●
Alarm
Supply Air Setpoint
Humidity Setpoint
SYSTEM STATUS CODE
SYSTEM OPERATING CODE
SYSTEM OPERATING MODE
RUN TIME HOURS
DEHUMIDIFICATION STATE
DEHUMIDIFICATION PERCENT
DAILY ZONE HI TEMP
DAILY ZONE LOW TEMP
FAN SPEED
COOLING VALVE OPEN %
SUPPLY TEMPERATURE
SUPPLY HUMIDITY
ZONE HIGH TEMP ALARM
ZONE LOW TEP ALARM
ZONE HUMIDITY LOW ALARM
ZONE HIGH HUMIDITY ALARM
AIR FILTER STATUS
ZONE HIGH TEMP ALARM
LEGEND
NEW DDCS POINT
EXISTING DDCS POINT
NETWORK POINT
DDCS POINT FUNCTION SCHEDULE
GRAPHICS ALARM LIMITSHARDWARE FAIL MODE SOFTWARE
| ZME-1800750-G001 Layout1 (1) |
| ZME-1800750-G002 Layout1 (1) |
| ZME-1800750-G003 Layout1 (1) |
| ZME-1800750-G004 Layout1 (1) |
| ZME-1800750-D101 Layout1 (1) |
| ZME-1800750-D102 Layout1 (1) |
| ZME-1800750-M101 Layout1 (1) |
| ZME-1800750-M501 Layout1 (1) |
| ZME-1800750-M502 Layout1 (1) |
| ZME-1800750-M601 Layout1 (1) |
| ZME-1800750-M901 Layout1 (1) |
| ZME-1800750-M902 Layout1 (1) |
| ZME-1800750-M903 Layout1 (1) |
| ZME-1800750-E101 Layout1 (1) |
| ZME-1800750-E102 Layout1 (1) |
| ZME-1800750-E601 Layout1 (1) |
| ZME-1800750-F101 Layout1 (1) |
File details come from the government source that posted it. Updated .