YWCA Hartford Region - Specs - Roof.pdf
PDF 23 MB Posted
- Attached to
- Roof Replacement
- Solicitation number
- 37653
- Issued by
- Hartford County, Connecticut
About this file
This is a technical specification document and bid invitation for a roof replacement project at YWCA Hartford Region, located at 135 Broad Street in Hartford, Connecticut, prepared by Northeast Collaborative Architects. The project consists of the installation of a new membrane roof system and replacement of skylights on the existing flat roof of the two-story office building, with the eight-story residential tower excluded from the scope of work. The specification document, dated April 8, 2026, establishes comprehensive requirements across multiple divisions including procurement and contracting requirements, general requirements, existing conditions, concrete, wood and composites, thermal and moisture protection, openings, and related construction elements. The work requires furnishing all labor, materials, and equipment necessary to complete the roofing system installation. Supporting documentation includes a Lead-Based Paint Inspection and Risk Assessment Report dated December 20, 2024, which was conducted by Eagle Environmental, Inc. within areas of the building associated with a proposed early childcare program; this inspection tested 235 painted surfaces and identified only three actionable readings on metal I-beam supports in a mechanical room scheduled for removal, with no toxic lead-based paint found in the proposed childcare areas.
The specifications establish detailed requirements for bid submission including a Bid Form, Bid Bond, Contractor Qualification Statement, Non-Collusion Certification, and Nondiscrimination Certification. Performance and Payment Bonds are required, along with compliance with wage rate requirements and Minority Business Enterprise provisions. The document incorporates AIA standard contract documents including General Conditions of the Contract for Construction (A201-2007) and related forms. Unit price procedures, substitution procedures, and contract modification procedures are detailed within the specifications. Submittal procedures, quality requirements, payment procedures, and project closeout requirements are established, including photographic documentation and project record documents. The specifications address temporary facilities and controls, product requirements, and execution standards. Additional compliance requirements include CHRO Good Faith Efforts requirements and prevailing wage rate schedules applicable to the Connecticut jurisdiction.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL SPECIFICATIONS
YWCA HARTFORD REGION
Roof Recovery
135 Broad St.
Hartford, CT. 06105
CD Specifications 4/8/2026
ARCHITECT
Northeast Collaborative Architects 11 Silver St. #116
Middletown, CT 06457 NCA Project #24011
SECTION 000110
TABLE OF CONTENTS
APRIL 8, 2026 YWCA HARTFORD REGION ROOF
PROJECT MANUAL: SPECIFICATIONS
Section 000100 Cover
Section 000110 Table of Contents Section 000115 Drawing Sheet list
DIVISION 00 – PROCUREMENT AND CONTRACTING REQUIREMENTS
Section 001116 Invitation to Bid Section 003126 Existing Hazardous Material Information Section 004113 Bid Form Section 004313 Bid Bond (A310) Section 004513 Contractor Qualification Statement (A305) Section 004519 Non-Collusion Section 004533. Nondiscrimination Certification Section 006113 Performance & Payment Bonds Section 006519.16 Release of Liens (AIA Document G706A) Section 006519.19 Contractor’s Final Payment (AIA Document G707-1994) Section 007200 General Conditions of the Contract for Construction (AIA Document A201- 2007) Section 007336 CHRO Good Faith Efforts Shor Form Plan Section 007339 Minority Business Enterprise Requirements Section 007343 Wage Rate Requirements Section 007343 Wage Rate Schedules
DIVISION 01 – GENERAL REQUIREMENTS
Section 011100 Summary of Work Section 012200 Unit Prices Section 012500 Substitution Procedures Section 012600 Contract Modification Procedures Section 012900 Payment Procedures Section 013100 Project Management and Coordination Section 013233 Photographic Documentation Section 013300 Submittal Procedures Section 014000 Quality Requirements Section 015000 Temporary Facilities and Controls Section 015800 Project Sign Section 016000 Product Requirements Section 017300 Execution Section 017700 Closeout Procedures Section 017823 Operation and Maintenance Data Section 017839 Project Record Documents
DIVISION 02 – EXISTING CONDITIONS
Section 024119 Selective Demolition
SECTION 000110
DIVISION 03 – CONCRETE
Section 034500 Precast Architectural Concrete
DIVISION 06 – WOODS, PLASTICS AND COMPOSITES
Section 061053 Miscellaneous Rough Carpentry
DIVISION 07 – THERMAL AND MOISTURE PROTECTION
Section 070150 Rehabilitation of Mod Bit Membrane Roofing Section 072100 Thermal Insulation Section 075423 Thermoplastic-Polyolefin (TPO) Roofing Section 076200 Sheet Metal Flashing and Trim Section 077200 Roof Accessories Section 079200 Joint Sealants
DIVISION 08 – OPENINGS
Section 086200 Unit Skylights
SECTION 000115
DRAWING SHEET LIST
DRAWING SHEET LIST
GENERAL
A-001 COVER SHEET
AD-100 ROOF DEMOLITION PLAN
A-100 ROOF CONSTRUCTION PLAN
A-301 BUILDING SECTIONS
A-401 ROOF DETAILS
Industrial Hygiene / IAQ Hazardous Building Materials Environmental Assessments Laboratory Services & Training
8 SOUTH MAIN STREET, SUITE 3 • TERRYVILLE, CT 06786
PHONE (860) 589-8257 • FAX (860) 585-7034
December 20, 2024
Mr. Todd Whitaker Facilities Manager YWCA Hartford Region 135 Broad Street Hartford, CT 06105
RE: Lead-Based Paint Inspection and Risk Assessment Report
Hartford, Connecticut Eagle Project No. 24-208.10T1
Dear Mr. Whitaker:
Please find the report for the Lead-Based Paint Inspection and Radon testing conducted at 135 Broad Street in Hartford, Connecticut (Site). The Lead-Based Paint Inspection and radon testing services were performed as part of the YWCA’s due diligence for proposed renovation activities to convert select areas within the Site building into early childcare program. The Client identified select locations that will be licensed under the childcare program.
Please do not hesitate to contact if you have any questions regarding the contents of this report.
Sincerely, Eagle Environmental, Inc.
Report Prepared By:
William Petrucci Environmental Consultant I
Report Reviewed By:
Chris Liberti Vice President of Operations
X:\2024 Files\2024 Reports\YWCA Hartford\135 Broad St - LIRA - Daycare.doc
EAGLE ENVIRONMENTAL, INC.
PHONE (860) 589-8257 • FAX (860) 585-7034
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Introduction
2.0 BACKGROUND INFORMATION
2.1 Scope of Inspection
2.2 Building Information
3.0 LEAD-BASED PAINT INSPECTION
3.1 Inspection Results
3.2 Risk Assessment
4.0 ENVIRONMENTAL SAMPLING
4.1 Dust Sampling Results
4.2 Soil Assessment Results
4.3 Water Sampling Results
4.4 Radon Testing Results
5.0 REGULATORY REQUIREMENTS
6.0 EXECUTIVE SUMMARY
APPENDICES
Appendix A Floor Plans Appendix B Standard Operating Procedures Appendix C XRF Lead-Based Paint Inspection Reports Appendix D Dust and Water Sample Laboratory Reports Appendix E Radon Testing Reports Appendix F Eagle Environmental, Inc. Certificates and License Appendix G Laboratory Certificate
PHONE (860) 589-8257 • FAX (860) 585-7034 1
1.0 INTRODUCTION
1.1 Introduction
Eagle Environmental, Inc. (Eagle) was retained by the YWCA Hartford Region to perform a lead-based paint inspection and radon testing for 135 Broad Street in Hartford, Connecticut (Site). The inspection was performed within the areas of the building which will be associated with a proposed the early childcare program. The lead-based paint inspection and risk assessment was performed on November 21, 2024 by William Petrucci; a State of Connecticut Department of Public Health (CT DPH) licensed Lead Inspector (license #002295).
2.0 BACKGROUND INFORMATION
2.1 Scope of Inspection
The scope of services included Lead-based paint testing utilizing an LPA-1 X-Ray Fluorescence (XRF) paint analyzer, dust sampling, lead-drinking-water sampling and radon testing. The Client’s representative identified the areas throughout the Basement and First-Floor level, which will be included in the childcare program’s licensing.
Additional areas outside the childcare program were inspected concurrently with this assessment in order to properly support the proposed renovation activities.
The following locations will be included in the licensed childcare program:
Basement level – Gymnasium Basement level – Corridors First Floor level – Soromundi Room Two (2) Stairwells First Floor level – Two (2) classrooms First Floor level – Restrooms First Floor level – Corridors and Closets
Floor plans identifying the childcare locations are attached in Appendix B.
2.2 Building Information
The Site building was constructed in 1974. The Basement consists of mechanical rooms, storage rooms, gym, pool, and locker rooms. The first-floor level consists of the entry lobby and offices. The second-floor level consists of mainly offices and conference rooms. The floors are concrete and covered with various types of vinyl flooring materials and carpet. The walls are masonry block and poured concrete in the mechanical rooms and of sheetrock and joint compound construction in most areas of the building. The ceilings consist of several types of suspended ceiling systems.
3.0 LEAD-BASED PAINT INSPECTION
3.1 Inspection Results
The lead-based paint inspection was performed utilizing an X-Ray Fluorescence (XRF) Sci-Apps X-550pb Lead Paint Analyzer (LPA 1), serial number 02230 within the limits of the inspection area(s). Room numbers designated by Eagle correspond to the attached
PHONE (860) 589-8257 • FAX (860) 585-7034 2
Lead-Based Paint Inspection XRF Report, located in Appendix C, and the floor plans attached in Appendix B. The “A” side is considered the front of the building with the “B”, “C” and “D” sides following in a clockwise direction.
For the purpose of this inspection, two hundred thirty-five (235) painted surfaces and components were tested with three (3) actionable readings. The actionable readings were identified on the metal I-beam frame supports to the overhead air handler unit within a mechanical room (Room 0-05) which is scheduled to be removed during the overall renovation project. The mechanical room is not located within the child-occupied areas associated with the proposed daycare.
At the time of the inspection, stairwell ST-2 was locked and inaccessible. The components appeared similar to those in stairwell ST-1 but additional testing will be required within the stairwell if it will be included within the childcare program’s licensing.
The lead-based paint inspection for the proposed childcare areas did not identify any of the tested components/surfaces to contain toxic levels of lead-based paint. The exterior proposed playground area was investigated, no painted surfaces or bare soil areas were identified. The exterior building facades included unpainted masonry walls and concrete columns.
Eagle did not test under any rigid enclosures. Components and or surfaces concealed under rigid enclosures are assumed to contain toxic levels of lead-based paint until tested and proven negative.
3.2 Risk Assessment
For the purpose of this inspection, toxic levels of lead-based paint were not identified within the proposed areas that will be converted into a childcare area. The XRF Lead Inspection Report is located in Appendix C.
4.0 ENVIRONMENTAL SAMPLING
4.1 Dust Sampling Results
Dust samples were collected from the floors and window sills within the inspected area of the proposed daycare and the adjoining hallways that are likely to be frequented by children under the age of six (6) years old. Dust sample results with concentrations of lead equal to or exceeding 10 µg/ft² on floors and 100 µg/ft² on window sills are considered to be dust-lead hazards.
The location of dust samples and results are provided in the following table:
Sample Number Location/Surface Sample Size Result 11-21-WP-01 1-09 D side floor 288 in² <1.0 µg/ft² 11-21-WP-02 1-09 B side floor 288 in² <1.0 µg/ft² 11-21-WP-03 1-09 A floor 288 in² <1.0 µg/ft² 11-21-WP-04 1-09 B floor 288 in² <1.0 µg/ft² 11-21-WP-05 1-08 D side floor 288 in² <1.0 µg/ft² 11-21-WP-06 1-08 B side floor 288 in² <1.0 µg/ft² 11-21-WP-07 1-17 floor 288 in² <1.0 µg/ft² 11-21-WP-08 1-18 floor 288 in² <1.0 µg/ft² 11-21-WP-09 1-10 Hallway floor 288 in² <1.0 µg/ft²
PHONE (860) 589-8257 • FAX (860) 585-7034 3
Sample Number Location/Surface Sample Size Result 11-21-WP-10 Field Blank N/A <10 µg/wipe 11-21-WP-11 Field Blank N/A <10 µg/wipe
No dust lead-hazards were identified in the areas where dust samples were collected.
4.2 Soil Assessment Results
A soil assessment was completed by Eagle during the lead-based paint inspection and risk assessment. Within the area of the proposed playground and rear entry, no bare soil was identified. Ground surfaces were covered by concrete walkways and bark mulch.
4.3 Water Sampling Results
Eagle collected two (2) first draw water samples and two (2) flush water samples from two (2) sinks located within the proposed daycare location. The first draw samples were confirmed by the building staff to have been sitting in the pipes for at least six (6) hours prior to sampling. The samples were collected in a one (1) Liter plastic collection bottle.
The sample was kept cool until analyzed by the laboratory.
The USEPA has set an action level of fifteen (15) parts per billion (ppb) (0.015 mg/Kg) as the lead in drinking water standard. Sample results that exceed this level may be harmful and pose a hazard to the consumer.
The location of the water sample and the result is provided in the following table:
The concentration of lead in the water samples collected from the sinks within Rooms 1- 09A and 1-09B were below the USEPA threshold of fifteen (15) ppb. No further action is necessary regarding lead in water.
4.4 Radon Testing Results
Radon is measured in PicoCuries per Liter of air or pCi/L. The USEPA has set an action level of 4.0 pCi/L. Ambient concentrations of radon are approximately 0.4 pCi/L of radon for outside air. The USEPA recommends that short term tests that have results of 4.0 pCi/L or greater be confirmed with a second short-term test. Two (2) short-term tests with results equal to or greater than 4.0 pCi/L require that radon mitigation be performed.
The charcoal canisters were sent to Radon Testing Corporation of America (RTCA) of Elmsford, New York for analysis. RTCA is listed in the USEPA Radon Measurement Proficiency (RMP) Program.
The location of the radon samples and the results are provided in the following table:
Sample Number Location Result 11-21-WP-CFD01 1-09A Sink – first draw 0.0022 mg/L (2.2 ppb) 11-21-WP-CF02 1-09A Sink – flush <0.0005 mg/L (<0.5ppb)
11-21-WP-BFD03 1-09B Left sink – first draw <0.0005 mg/L (<0.5ppb) 11-21-WP-BF04 1-09B Left sink – flush <0.0005 mg/L (<0.5ppb)
PHONE (860) 589-8257 • FAX (860) 585-7034 4
Canister ID# Test Start Test Stop Location Results (pCi/L)
4933842 11/21/2024 09:15
11/25/2024 08:11 Basement - Room 0-02 0.2
4934300 11/21/2024 09:20
11/25/2024 08:12
Basement - Room 0-06 (Left) 0.2
4934074 11/21/2024 09:22
11/25/2024 08:13
Basement Room 0-06 (Right) 0.3
4934327 11/21/2024 09:23
11/25/2024 08:13
Basement Room 0-06 (Right) - Duplicate 0.3
4934106 11/21/2024 09:26
11/25/2024 08:17 1st Floor Hallway 0.4
4934104 11/21/2024 09:30
11/25/2024 08:21
1st Floor - Proposed Daycare 0.1
4934078 11/21/2024 09:32
11/25/2024 08:21 Blank 0.1
Based on the results of this testing, all results fell below the USEPA action level of 4.0 pCi/L. No further testing is required at this time.
5.0 REGULATORY REQUIREMENTS
A Lead-Based Paint Correction Plan is not required for proposed daycare location as toxic levels of lead-based paint was not identified. No further action is required as it pertains to painted surfaces within the identified proposed daycare rooms.
A copy of this report should be maintained on Site in the event regulatory agencies request information pertaining to the inspected areas.
6.0 EXECUTIVE SUMMARY
Eagle Environmental, Inc. (Eagle) was retained by the YWCA Hartford Region to perform a lead-based paint inspection and risk assessment for the rooms associated with the proposed daycare within the Site building located at 135 Broad Street in Hartford, Connecticut (Site). The lead-based paint inspection and risk assessment was performed on November 21, 2024 by William Petrucci; a State of Connecticut Department of Public Health (CT DPH) licensed Lead Inspector (license #002295).
Lead-based paint equal to or exceeding 1.0 mg/cm² was not identified within the inspected area of the proposed daycare.
A complete list of components tested is identified in the Lead Paint Inspection Report located in Appendix C.
No dust-lead hazard was identified in the areas where dust wipes were collected.
PHONE (860) 589-8257 • FAX (860) 585-7034 5
No bare soils were identified within the proposed playground area during the soil assessment.
The concentration of lead in the water samples collected from Rooms 1-09A and 1-09B were below the USEPA threshold of fifteen (15) ppb. No further action is necessary regarding lead in water.
Any of the areas outside of the proposed childcare area, both interior and exterior, that have not been tested and confirmed to be negative for lead-based paint must be assumed to contain toxic levels of lead in paint and should be placed on the management plan to ensure all painted surfaces remain in intact condition. Components and surfaces concealed behind rigid enclosures or are otherwise inaccessible for testing must be assumed to contain toxic levels of lead-based paint for the purpose of this report.
A copy of this report should be maintained on Site in the event regulatory agencies request information pertaining to the inspected areas.
APPENDIX A
FLOOR PLANS
8 SOUTH MAIN STREET, SUITE 3
TERRYVILLE, CONNECTICUT 06786
860-589-8257
BP-1 BASEMENT
FP-1 FIRST FLOOR
DECEMBER 17, 2024
EAGLE PROJECT NUMBER: 24-208.10T1
135 BROAD STREET
HARTFORD, CONNECTICUT
Z:\2024 Files\2024 AutoCAD\YWCA\135 Broad Street\LBP Inspection\CAD\135 Broad Street.dwg
LOCATION MAP
Y.W.C.A. HARTFORD
INDEX OF DRAWINGS
KEY:
= LIMITS LEAD-BASED PAINT
INSPECTION AND RISK ASSESSMENT
= EAGLE ROOM NUMBER0-00
BASEMENT
NOT TO SCALE
BP-1
S
O U
T H
M
A I N
S
R
E E
T
S
U I T
E
T E
R R
Y V
I L
L E
C
O N
N E
C T
I C
U
L E
A D
B
A S
E D
P
I N
T
I N
S P
E C
T I O
N
A
R
S
K
A
S S
E S
S M
E N
T
Y W
C
A
H
A R
T F
O R
D
B R
O A
D S
TR
EE
T H
A R
TF
O
R D
, C O
N N
EC
TI
C U
T
PR
O
JE
C
T N
O
-2
.1
0T
D A
TE
: 1
2/
/2
D R
A W
N B
Y : B
B
R
EV
IE
W
ED
B
Y : P
F
SHEET OF
SHEET NO.
S I D
E D
SIDE-A (STREET SIDE)
SIDE-C
S I D
E B
1 2
Z:\2024 Files\2024 AutoCAD\YWCA\135 Broad Street\LBP Inspection\CAD\135 Broad Street.dwg
0-05
0-06
0-07
ST-2
0-02
0-01
ST-1
0-04
0-03
KEY:
= LIMITS LEAD-BASED PAINT
INSPECTION AND RISK ASSESSMENT
= EAGLE ROOM NUMBER0-00
FIRST FLOOR
NOT TO SCALE
FP-1
S
O U
H
M
S
R
E E
T
S
U I T
E
T E
R R
Y V
I L
L E
C
O N
N E
C T
I C
U
L E
A D
B
A S
E
P
I N
T
I N
S P
E C
T I O
N
A
R
S
K
A
S S
E S
S M
E N
T
Y W
C
A
H
A R
T F
O R
D
B R
O A
D S
TR
EE
T H
A R
TF
O
R D
, C O
N N
EC
TI
C U
T
PR
O
JE
C
T N
O
-2
.1
0T
D A
TE
: 1
2/
/2
D R
A W
N B
Y : B
B
R
EV
IE
W
ED
B
Y : P
F
SHEET OF
SHEET NO.
S I D
E D
SIDE-A (STREET SIDE)
SIDE-C
S I D
E B
2 2
Z:\2024 Files\2024 AutoCAD\YWCA\135 Broad Street\LBP Inspection\CAD\135 Broad Street.dwg
1-19
ST-1
1-14
1-09 1-08 1-18
1-17
ST-2
1-09B 1-09A
1-10
1-12
1-11
E
1-15
1-19
APPENDIX B
LEAD-BASED PAINT INSPECTION AND RISK ASSESSMENT
STANDARD OPERATING PROCEDURES
LEAD-BASED PAINT INSPECTION AND RISK ASSESSMENT
STANDARD OPERATING PROCEDURES
PART I – INTRODUCTION
A. PRINCIPLES OF LEAD-BASED PAINT INSPECTIONS AND RISK ASSESSMENTS
The intent of the lead-based paint inspection is to determine the presence or absence of hazardous levels of lead-based paint within the subject property. The intent of the risk assessment is to determine the nature and severity of health risks associated with the hazardous levels of lead.
The actual process of performing the combined lead inspection and risk assessment can be broken down into four (4) major components that include: 1. documentation of building and tenant data including family use patterns; 2. environmental sampling; 3. visually assessing the condition of painted surfaces and soil areas; and 4. presenting lead hazard control options.
The data collected from the first three components of the lead inspection and risk assessment helps the Risk Assessor identify the existence, source, location and severity of lead-based paint hazards and lead exposure pathways. This allows the Lead Designer/Planner to provide appropriate and efficient options for correcting lead hazards.
B. SCOPE OF INSPECTION
The inspection report provides a description of completed work within the executive summary.
The introduction section within the report identifies the location of the inspection site and scope of services within that location, as well as the date(s) of service. The name(s) of the lead inspector/risk assessors providing inspection services and appropriate State of Connecticut license number(s) are also incorporated in the report.
PART II – BACKGROUND INFORMATION
A. BUILDING INFORMATION
In general, building information is comprised of the current building description and construction history. Data collected in the field from the tenants or owner in addition to the information collected by the inspector aids in a general knowledge of building components and age of the structure. A site diagram is drawn and rooms are designated with numbers to correspond to the XRF inspection report. This information also assists in the development of management and control plans.
C. IDENTIFICATION OF DAYCARE AREAS
The inspector interviews the daycare administrators to find out exactly where the children will be within the building and on the grounds during the course of a normal day. Potential rooms tested include classrooms, cafeterias, hallways, stairwells, bathrooms, exterior entryways and play areas. The inspector relies upon the daycare administrators to accurately communicate this information.
PART III – LEAD-BASED PAINT INSPECTION
A. INSPECTION PROTOCOL
The building site is tested for lead-based paint using selected portions of the inspection protocol of chapter 7 of the Department of Housing and Urban Development (HUD) Guidelines for the
Evaluation and Control of Lead-Based Paint Hazards in Housing (1997 and 2012) Revision and the State of Connecticut Department of Public Health Childhood Lead Poisoning Prevention regulations to determine whether lead-based paint is present in a house, dwelling unit, residential building, or housing development including common areas and exterior surfaces, and, if present, which building components contain lead-based paint.
For the purpose of the inspection, lead-based paint is defined as paint or other surface coatings (stain, shellac or varnish) applied prior to 1978 and containing lead equal to or exceeding 1.0 milligrams per square centimeter (under the Environmental Protection Agency standards) or 0.5% by weight in a dried state (under Consumer Product Safety Commissioner).
Representative testing is conducted at the site. This includes testing a minimum of one (1) of each type of building component or surface within each room or room equivalent within the inspection area. Within each room, the ceiling and four (4) walls are tested. In addition, one (1) representative component type is tested in each room (i.e. window components, door components, baseboards, etc.). Unique building components are also tested within each room and room equivalent. This testing protocol is in accordance with the State of Connecticut Department of Public Health requirements for a lead-based paint inspection.
For the purpose of the inspection report and labeled as such on the site diagram, the "A" side is considered the front of the building with the "B", "C", and "D" sides following in clockwise order.
B. X-RAY FLUORESCENCE (XRF) TESTING RESULTS
Testing is conducted in accordance with the requirements of American Society for Testing and Materials (ASTM) Designation E2119 - 00, Standard Provisional Practice for Quality Systems for Conducting In Situ Measurements of Lead Content in Paint or Other Coatings Using Field- Portable X-ray Fluorescence (XRF) Devices.
Eagle utilizes SciAps X-550 X-Ray Fluorescence (XRF) Devices with serial numbers 2330 and 2339. Eagle follows the manufacturer recommended warm-up procedures prior to initiating testing. In addition, Eagle utilizes the red 1.03 mg/cm² Standard Reference Material (SRM) paint film, developed by the National Institute of Standards and Technology (NIST). An initial calibration check is performed followed by subsequent calibration checks at the completion of testing in a dwelling unit.
Results are presented in a Lead Paint Inspection Report, which consists of two (2) sections: a coversheet and detailed report. Results of lead based paint components and surfaces with results equal to or above 1.0 mg/cm² are located highlighted in red text throughout the report.
PART IV – VISUAL ASSESSMENT
A. GENERAL
The visual assessment is conducted to locate potential lead based paint hazards and to evaluate the magnitude of the hazard. The visual assessment identifies deteriorated painted surfaces, areas of visible dust accumulation, areas of bare soil, the presence of friction and impact surfaces, and the presence of painted surfaces on which it is possible for a child under six (6) years old to mouth (“chewable surfaces”). The information gathered during the visual assessment is used to identify areas where defective paint is present and to determine where potential dust and soil samples are to be collected and preliminarily evaluate exposure pathways to lead hazards.
B. CONDITION OF PAINTED SURFACES
The Risk Assessor conducts a room-by-room examination of the painted surfaces in the dwelling interior, common areas and exterior of the subject building. Painted surfaces are rated as "intact" or "deteriorated". This rating system is consistent with rating system described in Chapter 5 of the HUD Guidelines. Painted surfaces containing a lead concentration of 1.0 mg/cm² or greater and receiving a rating of "deteriorated" are considered lead hazards while painted surfaces rated as "intact" are not.
The visual assessment also evaluates the potential of factors that may contribute to deteriorated surface coatings, that ultimately result with a “deteriorated” rating such factors are ambient temperature, moisture and water damage.
C. FRICTION AND IMPACT SURFACES
The Risk Assessor evaluates if any painted surfaces containing a lead concentration of 1.0 mg/cm² or greater are subject to friction or impact.
Friction surfaces are surfaces that have moveable parts and rub against one another when operated. Windows and doors are the most common sources of friction surfaces. For example, window sashes, jambs, stops, parting beads and interior portion of sills are components of a window system that rub against one another when operated. The area on a door that comes into contact with the door jamb and stop may also be considered a friction surface. Floors and stair treads are examples of impact surfaces. Impact surfaces are surfaces that are subject to impact by forces such as foot traffic.
Both friction and impact surfaces, if coated with lead-based paint, may have varying degrees of damage and are a potential for generating lead dust or paint chips according to the frequency of paint abrasion.
D. SETTLED DUST ASSESSMENT
During the visual assessment, the Risk Assessor evaluated areas where settled dust may accumulate, such as on window sills, in window wells and on floors. Settled dust, if contaminated with lead, presents an exposure risk to children residing in the dwelling unit.
E. SOIL ASSESSMENT
Areas of bare soil around the dwelling and where children play may be contaminated with lead.
The risk assessment evaluates the potential for exposure to lead from soil. For the purpose of this risk assessment, the yard surrounding the building is evaluated to determine if visible paint chips and/or bare soil areas.
PART V – ENVIRONMENTAL SAMPLING
A. DUST SAMPLING
Eagle Environmental collects samples of settled dust from various locations throughout finished areas within the daycare. Areas where paint is rated as "deteriorated" condition and or areas that contain accumulations of settled dust are generally tested. Areas tested frequently include classrooms, eating areas, primary play areas and most commonly used entries.
The samples are collected utilizing a single-ply disposable ASTM wipe as the sampling media.
The inspector utilizes disposable latex gloves during the sampling procedure to avoid cross-contamination of the samples. Where feasible, samples are collected from hard smooth surfaces such as floors, window sills and window wells. The sampling area is one (1) square foot for floor surfaces or the actual area of the component wiped, for a smaller surface, such as a window sill.
Samples are collected while passing the wipe over the sampling area in an “S” type motion. For floor samples, the first pass is started at the top of the area, working vertically downward. The second pass is started at the side of the area, working laterally. The third pass is made around the edges of the designated sampling area. For window sills or wells, the area is wiped several times with the horizontal “S” type motion. The wipe samples are placed directly into fifty (50) milliliter centrifuge tubes. Two (2) blank wipe samples were submitted to the laboratory for analysis to examine the integrity of the testing process.
Currently, the State of Connecticut risk assessment standards for lead-contaminated dust wipe samples are equal to or exceeding forty (40) micrograms per square foot (µg/ft²) on floors and two-hundred and fifty (250) µg/ft² on window sills. Dust wipe sample results that exceed these levels are considered lead hazards.
B. SOIL SAMPLING
Eagle Environmental evaluates bare soil areas at the site to determine if sampling for lead in soil is warranted. In accordance with the regulations of Connecticut State Lead Poisoning, Prevention and Control Agency (PCSA), if bare soil areas that are not covered by grass, sod, other live ground covering or similar coverings are present, then soil samples should be collected. For the purposes of the evaluation, the site is characterized by areas of similar function and usage such as the dripline of the building, mid-yard, and children’s play areas.
Composite soil samples are collected where required. This entails collecting approximately five
(5) sub-samples within the area of evaluation and combining them. Sub-samples are only combined from similar evaluation areas (i.e. dripline samples are not composited with play areas, etc.).
The soil sampling is performed in accordance with the ASTM 1727 designation, Standard Practice for Field Collection of Soil Samples for Lead Determination by Atomic Absorption Spectrometry (AAS) Techniques, or its HUD approved equivalent.
The EPA states the following levels of concern for lead concentration levels present in bare soil:
equal to or above 400mg/kg in bare areas of soil, concentrations equal to or greater than 1,200 mg/Kg in child play area and equal to or exceeding 5,000 mg/kg will require permanent abatement under the EPA’s guidance.
C. PAINT CHIP SAMPLING
Paint chip sampling includes painted surfaces that were determined to be in the low positive range (1.0 mg/cm2) for the SciAps X-550 XRF inspection instrument. Paint chip sampling is performed in accordance with the requirements of the American Society of Testing and Materials standard E 1729 Standard Practice for Field Collection of Dried Paint Samples for Lead Determination by Atomic Absorption Spectrometry Techniques. Paint chip samples are analyzed by flame Atomic Absorption Spectrometry (AAS) utilizing the USEPA SW 846, 7420 method.
Specifically, a paint chip is collected to include all layers of paint on a surface, but not to include the substrate. Paint chips shall include a minimum of one (1) square inch of paint.
Paint chip analysis results that are equal to or exceed 0.5% lead by weight defined by Consumer Product Safety Commissioner are considered positive (lead-based). Paint chip analysis results below 0.5% lead by weight are negative.
D. WATER SAMPLING
Drinking water is sampled at primary sources of drinking water, including water fountains and kitchen sinks. First draw water samples are collected after allowing the water to stand in the pipes for at least six (6) hours. First draw samples evaluate the lead content that is leaching into the water supply from the domestic piping in the building. First draw samples also detect lead that may have leached from plumbing fixtures at the point of use.
Samples are collected in one (1) Liter plastic collection and kept cool in an ice filled cooler or refrigerated until analyzed by the laboratory. The standard USEPA threshold used for evaluation of results is fifteen (15) parts per billion (PPB) lead.
PART VII – DISCLOSURES AND NOTIFICATIONS
Certain federal and state requirements apply when lead hazards are found in a daycare site, For example, Eagle Environmental is required to notify the local health department when toxic levels of lead are identified. Eagle Environmental identifies the applicable regulations and explains the requirements within the body of the inspection report.
PART VIII – LABORATORY SERVICES
Dust, soil and paint chip samples are analyzed by EMSL Analytical of Carle Place, New York and Scientific Analytical Institute (SAI) of Greensboro, North Carolina.
Lead in drinking water samples are analyzed by Phoenix Environmental Laboratories, Inc. of Manchester, Connecticut.
Z:\SOP\Lead\SOP - (LIRA) use for Daycare with SciAps.doc
APPENDIX C
XRF LEAD-BASED PAINT INSPECTION REPORT
Lead-Based Paint Inspection Report
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
743 (CAL) PCS Pass 1.0 Timed
744 (CAL) PCS Pass 1.0 Timed
745 (CAL) PCS Pass 1.0 Timed
746 (CAL) PCS Pass 1.0 Timed
748 0-01 Pipe Metal Red Intact Negative 0.0 Quick
749 0-01 Pipe Metal Red Intact Negative 0.0 Quick
750 0-01 Pipe Metal Right Red Intact Negative 0.3 Quick
751 0-01 Pipe Metal Left Red Intact Negative 0.4 Quick
752 0-01 Pipe Metal Middle Red Intact Negative 0.1 Quick
753 0-01 Pipe Metal Middle Red Intact Negative 0.1 Quick
755 0-01 D Pipe Metal Right Red Intact Negative 0.0 Quick
756 0-01 D Pipe Metal Right Red Intact Negative 0.4 Quick
757 0-01 D Pipe Metal Middle Red Intact Negative 0.3 Quick
758 0-01 D Pipe Metal Middle Red Defective Negative 0.0 Quick
759 0-01 D Pipe Metal Left Red Defective Negative 0.8 Quick
760 0-01 D Pipe Metal Left Red Defective Negative -0.0 Quick
761 0-04 D Wall CMU White Intact Negative 0.0 Quick
762 0-04 C Wall CMU White Intact Negative -0.0 Quick
763 0-04 A Door Casing Metal White Intact Negative 0.0 Quick
764 0-04 A Door Jamb Metal White Intact Negative 0.1 Quick
Eagle Environmental, Inc 8 South Main Street, Suite #3, Terryville, CT 06786
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
765 0-04 A Door Stop Metal White Intact Negative 0.1 Quick
766 0-04 A Door Header Metal White Intact Negative 0.0 Quick
767 0-03 Ceiling Track Metal White Intact Negative 0.0 Quick
768 0-03 A Wall CMU White Intact Negative 0.0 Quick
769 0-03 D Wall CMU White Intact Negative 0.0 Quick
770 0-03 A Door Casing Metal White Intact Negative 0.0 Quick
771 0-03 A Door Jamb Metal White Intact Negative 0.1 Quick
772 0-03 A Door Stop Metal White Intact Negative 0.0 Quick
773 0-03 A Door Header Metal White Intact Negative 0.0 Quick
774 0-02 A Wall CMU White Intact Negative -0.0 Quick
775 0-02 B Wall CMU White Intact Negative 0.0 Quick
776 0-02 C Wall CMU White Intact Negative -0.0 Quick
777 0-02 D Wall CMU White Intact Negative 0.0 Quick
778 0-02 A Door Casing Metal Left White Intact Negative 0.0 Quick
779 0-02 A Door Jamb Metal Left White Intact Negative 0.0 Quick
780 0-02 A Door Stop Metal Left White Intact Negative 0.0 Quick
781 0-02 A Door Casing Metal Right White Intact Negative 0.0 Quick
782 0-02 A Door Jamb Metal Right Blue Defective Negative 0.0 Quick
783 0-02 A Door Stop Metal Right White Intact Negative 0.0 Quick
784 0-02 B Door Casing Metal Left White Intact Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
785 0-02 B Door Stop Metal Left White Intact Negative 0.1 Quick
786 0-02 B Door Jamb Metal Left White Intact Negative 0.0 Quick
787 0-02 B Door Casing Metal Left Center White Intact Negative 0.0 Quick
788 0-02 B Door Jamb Metal Left Center White Intact Negative 0.0 Quick
789 0-02 B Door Stop Metal Left Center White Intact Negative 0.0 Quick
790 0-02 B Door Casing Metal Right Center White Intact Negative 0.0 Quick
791 0-02 B Door Jamb Metal Right Center White Intact Negative 0.0 Quick
792 0-02 B Door Stop Metal Right Center White Intact Negative 0.0 Quick
793 0-02 B Door Stop Metal Right White Intact Negative 0.1 Quick
794 0-02 B Door Jamb Metal Right White Intact Negative 0.0 Quick
795 0-02 B Door Stop Metal Right White Intact Negative 0.1 Quick
796 0-02 B Door Metal Right White Intact Negative 0.0 Quick
797 0-02 C Door Casing Metal Left White Intact Negative 0.0 Quick
798 0-02 C Door Jamb Metal Left White Intact Negative 0.0 Quick
799 0-02 C Door Stop Metal Left White Intact Negative 0.1 Quick
800 0-02 D Door Casing Metal White Intact Negative 0.0 Quick
801 0-02 D Door Stop Metal Blue Defective Negative 0.0 Quick
802 0-02 D Door Jamb Metal Blue Defective Negative 0.0 Quick
803 0-02 D Door Casing Metal Right Maroon Intact Negative 0.1 Quick
805 0-06 B Pipe Metal White Intact Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
806 0-06 B Closet Ceiling Metal No Paint Intact Negative 0.0 Quick
807 0-02 Column Metal Right White Intact Negative -0.0 Quick
808 0-02 Column Concrete Right White Intact Negative 0.0 Quick
809 0-07 A Wall CMU Yellow Defective Negative 0.0 Quick
810 0-07 B Wall CMU Yellow Defective Negative 0.0 Quick
811 0-07 C Wall CMU Yellow Intact Negative 0.0 Quick
812 0-07 D Wall CMU Yellow Intact Negative 0.0 Quick
813 0-07 D Column Concrete Yellow Intact Negative -0.0 Quick
814 0-07 A Door Casing Metal Blue Defective Negative 0.0 Quick
815 0-07 A Door Jamb Metal Blue Defective Negative 0.0 Quick
816 0-07 A Door Stop Metal Blue Defective Negative 0.0 Quick
817 0-07 B Door Casing Metal Brown Defective Negative 0.0 Quick
818 0-07 B Door Jamb Metal Brown Defective Negative 0.0 Quick
819 0-07 B Door Stop Metal Brown Defective Negative 0.0 Quick
820 0-07 C Door Casing Metal Brown Defective Negative 0.0 Quick
821 0-07 C Door Jamb Metal Brown Defective Negative 0.0 Quick
822 0-07 C Door Stop Metal Brown Defective Negative 0.0 Quick
823 0-07 D Door Casing Metal Brown Defective Negative 0.1 Quick
824 0-07 D Door Jamb Metal Brown Defective Negative 0.0 Quick
825 0-07 D Door Stop Metal Brown Defective Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
826 0-07 D Door Metal Brown Defective Negative 0.0 Quick
827 0-07 A Door Metal Red Intact Negative 0.0 Quick
828 0-07 B Door Metal Brown Defective Negative 0.0 Quick
829 0-05 I-Beam Metal Green Defective Positive 1.4 Quick
830 0-05 I-Beam Metal Left Green Defective Positive 1.2 Quick
831 0-05 I-Beam Metal Rear Green Defective Negative 0.7 Quick
832 0-05 I-Beam Metal Rear Green Defective Positive 1.6 Quick
833 0-05 I-Beam Metal Upper Green Defective Negative 0.7 Quick
834 0-05 Air Handler Unit Metal Left Blue Defective Negative 0.0 Quick
835 0-05 Air Handler Unit Metal Right Blue Defective Negative 0.3 Quick
836 0-05 Pipe Metal Right Red Defective Negative 0.0 Quick
837 0-05 B Door Casing Metal Brown Defective Negative 0.0 Quick
838 0-05 B Door Stop Metal Brown Defective Negative 0.0 Quick
839 0-05 B Door Stop Metal Brown Defective Negative 0.0 Quick
840 0-05 A Stairs Railing Metal Brown Defective Negative 0.6 Quick
841 0-05 A Stairs Stringer Metal Brown Defective Negative 0.6 Quick
842 0-05 A Stairs Tread Metal Brown Defective Negative 0.1 Quick
843 ST-01 B Door Casing Metal White Intact Negative 0.0 Quick
844 ST-01 B Door Jamb Metal White Intact Negative 0.0 Quick
845 ST-01 B Door Stop Metal White Intact Negative 0.1 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
846 ST-01 A Wall CMU White Intact Negative -0.0 Quick
847 ST-01 B Wall CMU White Intact Negative 0.0 Quick
848 ST-01 C Wall CMU White Intact Negative 0.0 Quick
849 ST-01 D Wall CMU White Intact Negative 0.0 Quick
850 ST-01 B Door Metal White Intact Negative 0.0 Quick
851 ST-01 Stairs Tread Metal Maroon Intact Negative 0.0 Quick
852 ST-01 Stairs Riser Metal Black Intact Negative 0.2 Quick
853 ST-01 Stairs Stringer Metal Brown Defective Negative 0.5 Quick
854 ST-01 Ceiling Sheetrock White Intact Negative 0.0 Quick
855 ST-01 D Door Casing Metal Maroon Defective Negative 0.0 Quick
856 ST-01 D Door Jamb Metal Maroon Defective Negative 0.0 Quick
857 ST-01 D Door Stop Metal Maroon Defective Negative 0.0 Quick
858 1-10 C Door Casing Metal Brown Intact Negative 0.0 Quick
859 1-10 C Door Jamb Metal Brown Defective Negative 0.0 Quick
860 1-10 C Door Stop Metal Brown Defective Negative 0.0 Quick
861 1-10 D Door Casing Metal Left Brown Defective Negative 0.0 Quick
862 1-10 C Door Metal Brown Defective Negative 0.0 Quick
863 1-10 C Door Metal Maroon Defective Negative 0.1 Quick
864 1-10 C Door Jamb Metal Maroon Defective Negative 0.1 Quick
865 1-10 C Door Stop Metal Maroon Defective Negative 0.1 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
866 1-10 D Wall CMU Yellow Intact Negative 0.0 Quick
867 1-10 B Wall CMU Yellow Intact Negative -0.0 Quick
868 1-10 B Door Casing Metal Right Maroon Intact Negative 0.0 Quick
869 1-10 B Door Jamb Metal Right Maroon Intact Negative 0.0 Quick
870 1-10 B Door Stop Metal Right Maroon Intact Negative 0.0 Quick
871 1-10 B Door Casing Metal Left Maroon Intact Negative 0.0 Quick
872 1-10 B Door Jamb Metal Left Maroon Intact Negative 0.0 Quick
873 1-10 B Door Stop Metal Left Maroon Defective Negative 0.0 Quick
874 1-10 B Wall Sheetrock White Intact Negative 0.0 Quick
875 1-10 A Window Frame Metal Brown Intact Negative 0.0 Quick
876 1-10 A Window Sash Metal Brown Intact Negative 0.0 Quick
877 1-10 A Door Casing Metal Brown Intact Negative -0.0 Quick
878 1-10 A Door Jamb Metal Brown Intact Negative 0.0 Quick
879 1-10 A Door Stop Metal Brown Intact Negative 0.0 Quick
880 1-10 A Door Metal Brown Intact Negative 0.0 Quick
881 1-10 C Door Metal Right Maroon Intact Negative 0.0 Quick
882 1-10 D Door Casing Metal Right Maroon Intact Negative 0.0 Quick
883 1-10 D Door Jamb Metal Right Maroon Defective Negative 0.0 Quick
884 1-10 D Door Stop Metal Right Maroon Defective Negative 0.0 Quick
885 1-10 A Wall CMU Yellow Intact Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
886 1-10 A Window Sill Metal Brown Defective Negative 0.0 Quick
887 1-10 A Window Casing Metal Brown Defective Negative 0.1 Quick
888 1-08/1-09 C Wall Sheetrock Yellow Defective Negative 0.0 Quick
889 1-08/1-09 C Wall CMU Yellow Intact Negative 0.0 Quick
890 1-08 B Wall Sheetrock Yellow Defective Negative 0.0 Quick
891 1-08 B Wall CMU Yellow Defective Negative -0.0 Quick
892 1-18 B Wall Sheetrock Yellow Defective Negative 0.0 Quick
893 1-18 C Wall Sheetrock Yellow Defective Negative 0.0 Quick
894 1-17 B Wall Sheetrock Yellow Intact Negative 0.0 Quick
895 1-17 A Wall Sheetrock Yellow Defective Negative 0.0 Quick
896 1-17 D Shelf Support Wood White Defective Negative 0.0 Quick
897 1-17 C Wall Sheetrock Yellow Defective Negative 0.0 Quick
898 1-17 C Wall CMU Yellow Defective Negative -0.0 Quick
899 1-17 B Wall Sheetrock Yellow Defective Negative 0.0 Quick
900 1-15 A Wall Sheetrock Yellow Intact Negative 0.0 Quick
901 1-15 B Wall Sheetrock Yellow Intact Negative 0.0 Quick
902 1-15 C Wall Sheetrock Yellow Intact Negative 0.0 Quick
903 1-15 D Wall Sheetrock Yellow Defective Negative -0.0 Quick
904 1-15 D Door Casing Metal Brown Defective Negative 0.0 Quick
905 1-15 D Door Jamb Metal Brown Defective Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
906 1-15 D Door Stop Metal Brown Defective Negative 0.0 Quick
907 1-16 A Wall Sheetrock Yellow Defective Negative 0.0 Quick
908 1-16 B Wall Sheetrock Yellow Defective Negative -0.0 Quick
909 1-16 D Wall Sheetrock Yellow Defective Negative 0.0 Quick
910 1-11 A Window Sash Metal Brown Intact Negative 0.0 Quick
911 1-11 A Window Casing Metal Brown Intact Negative 0.0 Quick
912 1-14 A Wall CMU Yellow Intact Negative 0.0 Quick
913 1-14 B Wall CMU Yellow Intact Negative 0.0 Quick
914 1-14 D Wall CMU Yellow Intact Negative -0.0 Quick
915 1-14 C Wall CMU Yellow Intact Negative -0.0 Quick
916 1-14 A Door Casing Metal Maroon Intact Negative 0.0 Quick
917 1-14 A Door Jamb Metal Maroon Intact Negative 0.0 Quick
918 1-14 A Door Stop Metal Maroon Intact Negative 0.0 Quick
919 1-14 A Door Metal Maroon Intact Negative 0.0 Quick
920 1-14 B Door Metal Maroon Intact Negative 0.0 Quick
921 1-14 B Door Casing Metal Maroon Intact Negative 0.0 Quick
922 1-14 B Door Stop Metal Maroon Intact Negative 0.1 Quick
923 1-14 B Door Jamb Metal Maroon Intact Negative 0.1 Quick
924 1-14 D Door Casing Metal Maroon Intact Negative 0.1 Quick
925 1-14 D Door Stop Metal Maroon Intact Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
926 1-14 B Door Casing Metal Right Brown Intact Negative 0.0 Quick
927 1-14 C Door Casing Metal Brown Intact Negative 0.0 Quick
928 1-14 C Door Metal Brown Intact Negative 0.0 Quick
929 1-14 C Door Jamb Metal Brown Intact Negative 0.0 Quick
930 1-14 C Door Stop Metal Brown Intact Negative 0.0 Quick
931 1-10 Ceiling Deck Metal No Paint Intact Negative 0.0 Quick
932 1-13 A Door Casing Metal Maroon Defective Negative 0.0 Quick
933 1-13 A Door Jamb Metal Maroon Defective Negative 0.0 Quick
934 1-13 A Door Stop Metal Maroon Defective Negative 0.0 Quick
935 1-13 A Door Jamb Metal Left Brown Defective Negative 0.0 Quick
936 1-13 A Door Stop Metal Left Brown Defective Negative 0.0 Quick
937 1-13 B Door Casing Metal Left Brown Intact Negative 0.0 Quick
938 1-13 B Door Jamb Metal Left Brown Intact Negative 0.1 Quick
939 1-13 C Door Casing Metal Left Brown Intact Negative 0.0 Quick
940 1-13 C Door Casing Metal Right Brown Intact Negative 0.0 Quick
941 1-13 D Door Casing Metal Brown Intact Negative 0.0 Quick
942 1-13 Ceiling Sheetrock White Intact Negative 0.0 Quick
943 1-13 Ceiling Plaster White Intact Negative -0.0 Quick
944 1-13 B Door Casing Metal Left Brown Intact Negative 0.0 Quick
945 1-13 B Door Jamb Metal Left Brown Intact Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
946 1-13 B Door Stop Metal Left Brown Intact Negative 0.0 Quick
947 2-38 A Wall Sheetrock White Intact Negative 0.0 Quick
948 2-38 C Wall Sheetrock White Intact Negative 0.0 Quick
949 2-38 A Door Casing Metal Brown Defective Negative 0.0 Quick
950 2-22 C Wall Sheetrock Gray Intact Negative 0.0 Quick
951 2-22 A Wall Sheetrock Gray Defective Negative 0.0 Quick
952 2-22 D Window Sill Metal Brown Intact Negative 0.0 Quick
953 2-22 D Window Parting Bead Metal Brown Intact Negative 0.0 Quick
954 2-23 A Wall Sheetrock Blue Defective Negative -0.0 Quick
955 2-23 C Wall Sheetrock Blue Defective Negative 0.0 Quick
956 2-36 C Wall Sheetrock Gray Defective Negative -0.0 Quick
957 2-24 D Wall Sheetrock Gray Defective Negative 0.0 Quick
958 2-24 C Wall Sheetrock Gray Defective Negative -0.0 Quick
959 2-24 C Door Casing Metal Yellow Defective Negative 0.0 Quick
960 2-25 C Door Casing Metal Yellow Defective Negative -0.0 Quick
961 2-25 C Wall Sheetrock Gray Defective Negative 0.0 Quick
962 2-25 B Wall Sheetrock Gray Defective Negative 0.0 Quick
963 2-26 B Wall Sheetrock Gray Defective Negative 0.0 Quick
964 2-26 A Wall Sheetrock Gray Defective Negative 0.0 Quick
965 2-34 B Wall Sheetrock Yellow Defective Negative 0.0 Quick
Inspection Site: YWCA Hartford Inspection Date: 11/20/2024 - 11/21/2024 Unit Started: 11/20/2024 08:55:08
135 Broad Street, Total Readings: 235 Unit Ended: 11/21/2024 01:37:38
Hartford, CT 06105 Action Level: 1.0 (mg/cm²) Classification Level: 1.0 (mg/cm²)
Test # Room Wall Structure Components Substrate Position Color Conditition Result Lead Mode Notes (mg/cm²)
966 2-34 C Wall Sheetrock Yellow Defective Negative -0.0 Quick
967 2-20 B Wall Sheetrock Yellow Intact Negative 0.0 Quick
968 2-20 C Wall Sheetrock Yellow Intact Negative 0.0 Quick
969 2-20 D Door Casing Metal Brown Intact Negative 0.0 Quick
970 2-20 A Door Casing Metal Brown Intact Negative 0.0 Quick
971 2-20 B Door Casing Metal Left Brown Intact Negative 0.0 Quick
972 2-20 B Door Casing Metal Right Brown Intact Negative 0.0 Quick
973 2-21 C Wall Sheetrock Yellow Intact Negative 0.0 Quick
974 2-21 B Wall Sheetrock Yellow Intact Negative -0.0 Quick
975 2-30 C Cased Opening Metal Yellow Intact Negative 0.0 Quick
976 2-30 C Wall Sheetrock Beige Intact Negative 0.0 Quick
977 (CAL) PCS Pass 1.1 Timed
978 (CAL) PCS Pass 1.1 Timed
979 (CAL) PCS Pass 1.1 Timed
980 (CAL) PCS Pass 1.1 Timed
--- End of Readings ---
APPENDIX D
DUST AND WATER SAMPLE LABORATORY REPORTS
Analysis for Lead Concentration in Wipe Samples by Flame Atomic Absorption Spectroscopy
EPA SW-846 3050B/6010C/7000B
Customer: Eagle Environmental, Inc 8 South Main Street Suite 3 Terryville, CT 06786
Analysis:
Victoria Farkas Aaron Hatcher Breigh Ashe
10069090Lab Order ID:Attn:
PBW
Date Received: 11/25/2024
Project: YWCA Hartford- 135 Bcoad Street, Hartford Date Reported: 11/26/2024
Sample ID
Lab Sample ID
Description
Lab Notes
Concentration (µg)
Concentration (µg/ft²)
Area (ft²)
Reporting Limit (μg)
11-21-WP-01
10069090_0001
1-09 D side floor 2 <2.0 <1.02.0
11-21-WP-02
10069090_0002
1-09 B side floor 2 <2.0 <1.02.0
11-2…
This is the start of the file's text. The full file is on GovTribe.