This file comprises architectural and engineering drawings for the Administration Center Redistricting Renovation (Chambers Dais) project in Orange County, Florida, prepared by Rhodes+Brito Architects, Kaleidoscope Interior Design, and Bobes Associates. The project involves a Level 1 alteration to the dais bench in the BCC Chambers Room (Room 104) on the first floor of the Orange County Administration Building located at 400 E South Street, Orlando, Florida. The renovation accommodates two new county commissioners through reconfiguration of the existing dais bench with new finishes, including solid surface work surfaces (Wilsonart Morning Ice), new LED lighting strips, above-counter power receptacles with USB and USB-C connections, new presentation monitors, and undercounter wireless duress alarm call buttons. The design team includes mechanical, electrical, fire protection, and technology specialists. The project requires coordination with multiple building systems including the existing Lenel OnGuard access control system, new discussion system controllers with integrated speakers and gooseneck microphones at each commissioner station, and new VGA distribution amplifiers for monitor signal distribution. Sealed bids are due electronically through the OpenGov e-Procurement Platform by February 10, 2026, at 4:00 p.m. EST, with a non-mandatory pre-bid meeting scheduled for January 14, 2026, at 1:00 p.m. Questions must be submitted by January 26, 2026, at 5:00 p.m. EST.
The estimated project cost is $200,000.00. Bidders must be registered with E-Verify, maintain a drug-free workplace, and provide at least three references for similar commercial construction projects completed within the last ten years. A bid bond of not less than 10 percent of the total estimated contract amount is required, along with payment and performance bonds upon award. The county will retain 5 percent retainage from progress payments. All work must comply with the Florida Building Code (8th Edition, 2023), the 2020 National Electrical Code, City of Orlando Building Department requirements, and all applicable local, county, and state codes and standards. The contractor is responsible for temporary power and lighting during construction and must provide comprehensive warranty coverage including one-year full warranty on all work and materials, with extended warranties for structured cabling (25 years) and emergency lighting batteries. The project requires coordination with Orange County Information Systems and Services (ISS) and Enterprise Security, with specific technology standards including Siemon certified cabling, Audio-Technica discussion systems, and integration with the existing access control infrastructure. The contract will be awarded to the lowest responsive and responsible bidder.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
THIS PROJECT IS THE RENOVATION OF THE
DAIS BENCH IN THE BCC CHAMBERS ROOM
ON THE FIRST FLOOR OF THE ORANGE
COUNTY ADMINSTRATION BUILDING. THE
BENCH WILL BE RECONFIGURED TO
ACCOMODATE THE TWO NEW COUNTY
COMMISSIONERS AND WILL RECEIVE NEW
FINISHES. THIS IS A LEVEL 1 ALTERATION
TO FINISHES ONLY.
PROJECT SCOPE
VICINITY MAP
PROJECT DESIGN TEAM
RHODES+BRITO ARCHITECTS 605 E.
ROBINSON ST, SUITE 750
ORLANDO, FL 32801
PH. (407) 648-7288
CONTACT: LORI GODBOLD, AIA, NCARB
ARCHITECTURE
KALEIDOSCOPE INTERIOR DESIGN
SUITE
CITY, FL 12345
PH: (407) 702-8208
CONTACT: MANDY WANNEN, LEED SP, EDAC, ALEP
INTERIORS
BOBES ASSOCIATES
150 CIRCLE DRIVE
MAITLAND, FL 32751
PH: (407) 628-0882
CONTACT: GUS BOBES JR, P.E.
FIRE
PROTECTION
A C CT T SEH IR
AR0014284
BOBES ASSOCIATES
150 CIRCLE DRIVE
MAITLAND, FL 32751
PH: (407) 628-0882
CONTACT: GUS BOBES JR, P.E.
MECHANICAL
BOBES ASSOCIATES
150 CIRCLE DRIVE
MAITLAND, FL 32751
PH: (407) 628-0882
CONTACT: GUS BOBES JR, P.E.
ELECTRICAL
BOBES ASSOCIATES
150 CIRCLE DRIVE
MAITLAND, FL 32751
PH: (407) 628-0882
CONTACT: GUS BOBES JR, P.E.
TECHNOLOGY
NICOLE H. WILSON CHRISTINE MOORE
District 1 Commissioner District 2 Commissioner
MAYRA URIBE MARIBEL GOMEZ CORDERO
District 3 Commissioner District 4 Commissioner
KELLY MARTINEZ SEMRAD MICHAEL "MIKE" SCOTT
District 5 Commissioner District 6 Commissioner
JERRY L. DEMINGS
ORANGE COUNTY MAYOR
BOARD OF COUNTY COMMISSIONERS
ORANGE COUNTY ADMINISTRATION
BUILDING BCC CHAMBERS DAIS BENCH
RENOVATION
Permit Documents
11/20/2025
ORANGE COUNTY GOVERNMENT
400 EAST SOUTH STREET, SUITE 500
ORLANDO, FL 32801
G000
INDEX OF DRAWINGS
G000 COVER, INDEX
ID101 DAIS MILLWORK
E001 ELECTRICAL GENERAL NOTES
E101 POWER+LIGHTING+SYSTEM DEMOLITION PLAN
E102 POWER+LIGHTING+SYSTEMS RENOVATION PLAN
DATE SUBMISSION / REVISION NO.
r h o d e s + b r i t o A R C H I T E C T S
A
A101
A2
A711
A2
A711
MATERIALS LEGEND
DRAWING FORMAT
DIMENSIONING SHEET NUMBERING
100 SF
A101
A711A scale:
drawn:
check:
date:
project no: 2001.001
01.01.01 date
Client Logo and
Project Title
ALL
REPRODUCTION
AND
INTELLECTUAL
PROPERTY
RIGHTS
RESERVED
CLIENT LOGO
HERE
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
19.02
TYP
TYP
G1
E1
C1
A1 A3
C3
E3
G3
A5 A7 A9
C5
EACH SHEET IS DIVIDED INTO A GRID. AN ALPHA-NUMERIC GRID COORDINATE SYSTEM IS USED TO ORGANIZE THE DRAWING TITLES
DRAWING TITLES ARE NUMBERED ACCORDING TO ITS LOCATION ON THE GRID. THE LOWER LEFT HAND CORNER GRID OF THE
DRAWING IS USED AS THE IDENTIFICATION NUMBER (SEE DIAGRAM).
COLUMN CENTERLINE
PARTITIONS ARE DIMENSIONED TO FACE OF STUDS, FACE OF CMU AND FACE OF
BLOCK UNLESS INDICATED OTHERWISE
DIMENSIONS ARE INDICATED ON DRAWINGS, DO NOT SCALE DRAWINGS
6.
7.
PARTITION
KEYNOTE
REFERENCE
ELEVATION
REFERENCE
REVISION
IDENTIFICATION
PARTITION TYPE
IDENTIFICATION
WINDOW TYPE
REVISION NUMBER
(REFER TO TITLE
BLOCK)
TARGET ELEVATION
TARGET DESCRIPTION
WINDOW DESIGNATION
(REFER TO WINDOW
SCHEDULE)
REFERENCE NUMBER
PARTITION TYPE
(REFER TO PARTITION
TYPE DETAILS)A
GRAPHIC
SCALE
INDICATES FEET
WHEN A ROOM/BUILDING/OBJECT CENTERLINE IS INDICATED, ONLY ONE SIDE OF
ELEMENT MAY BE DIMENSIONED
PARTITIONS WITH FINISH FACE FLUSH WITH FINISH FACE OF COLUMN WILL NOT BE
DRAWN ON SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER
SCALE DRAWINGS.
COLUMN CENTERLINE
PARTITION FINISH FACE ON COLUMN OR GRID LINE WILL NOT BE DIMENSIONED ON
SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE
DRAWINGS.
PARTITIONS CENTERED ON COLUMNS OR GRID LINES WILL NOT BE DIMENSIONED ON
SMALL SCALE PLANS BUT WILL BE DRAWN ACCORDINGLY ON LARGER SCALE
DRAWINGS.
5.
4.
PARTITION
3.
B. AS DIMENSIONED
COLUMN CENTERLINE
PARTITION
DOOR LOCATION
DOORS ARE LOCATED BY ONE OF THE FOLLOWING:
A. ONE JAMB FACE LOCATED BY A PARTITION AT RIGHT ANGLE.
2.
1.
PARTITION
DOOR
SINGLE INTERIOR
ELEVATION
REFERENCE
RESTROOM
ACCESSORY
IDENTIFICATION
DOOR NUMBER
SPOT
ELEVATION
REFERENCE
TRUE
NORTH ARROWDOOR NUMBER
(SEE DOOR SCHEDULE)
TARGET ELEVATION
ACCESSORY TYPE
(REFER TO RESTROOM
ACCESSORY SCHEDULE)A
ELEVATION DETAIL NUMBER
ELEVATION ORIENTATION
SHEET NUMBER ON WHICH
ELEVATION OCCURS
ROOM AREA
WALL SECTION
OR BUILDING
SECTION
REFERENCE
ROOM NUMBER
SHEET NUMBER ON
WHICH SECTION OCCURS
SECTION ORIENTATION
SECTION DETAIL NUMBER
ROOM NAME
COLUMN
IDENTIFICATION
B
CALLOUT DETAIL
REFERENCE
A501
A1
COLUMN CENTERLINE
DRAWING ON WHICH
DETAIL OCCURS
DETAIL NUMBER
REVISION SYMBOLS
REVISION AREA
REVISION DELTA
SUBCATEGORY
SHEET NUMBER
ITEM
CATEGORY
DISCIPLINE:
L - Landscape
S - Structural
A - Architectural
P - Plumbing
E - Electrical
M - Mechanical (HVAC)
C - Civil
RIGID INSULATION
POROUS FILL
GYPSUM BOARD /
GROUT FILL
BATT INSULATION
STEEL
PLYWOOD
(OR GLULAM)
CONTINUOUS
ROUGH LUMBER
DISCONTINUOUS
ROUGH LUMBER
CONCRETE MASONRY UNITSFINISH LUMBER
CONCRETE
EARTH
PROJECT
NORTH ARROW
DRAWING INDEX
BEXISTING COLUMN
IDENTIFICATION
LIST OF ABBREVIATIONS
MISCELLANEOUS CHANNEL
MECHANICAL/ELECTRICAL/PLUMBING
LAMINATED VENEER LUMBER
COMPT COMPARTMENT
BW
BVL
BOTH WAYS
BEVELED
BM
BSL
BS
BOT
BRK
BUR
BRG PL
BRG
BSMT
BO
BD
BLDG
BLK(G)
BIT
BET
BEL
BENCH MARK
BUILDING SETBACK LINE
BUILT UP ROOFING
BOTH SIDES
BEARING PLATE
BOTTOM OF
BASEMENT
BRICK
BEARING
BOTTOM
BITUMINOUS
BLOCK(ING)
BUILDING
BOARD
BETWEEN
BELOW
CP
CT
CYD
CORR
CRS
CR
CSMT
CENTER POINT
CUBIC YARD
COURSE(S)
CORRUGATED
CERAMIC TILE
CHROMIUM (PLATED)
CASEMENT
ADDENDUMADD
A/V
AUTO
ASPH
ASB
ARCH
APROX
ANOD
AP
AHU
A/E
ADD'D
ANC
ALUM
ALT
ADJ
ADH
AFF
ANCHOR(AGE)
AUDIO VISUAL
ACCESS PANEL
APPROXIMATE
ARCHITECT(URAL)
ANODIZED
ASBESTOS
ASPHALT
AUTOMATIC
AIR HANDLING UNIT
ARCHITECT/ENGINEER
ADDITIONAL
ABOVE FINISHED FLOOR
ADJUSTABLE
ADHESIVE
ALTERNATE
ALUMINUM
AD
AB
A/C
ACT
ACPL
AC
ACC
ABV
ACOUSTICAL
ACOUSTICAL PLASTER
ACOUSTICAL TILE
AIR CONDITIONING
ANCHOR BOLT
AREA DRAIN
ABOVE
ACCESS
CI CAST IRON
CNTRSNK
CO
CONN
CONT
CONTR
CONST
CONC
COL
CNTR
CLOS
CK
CJ
CMU
CLS
CLR
CIR
CLC
CIP
CONNECTION
COUNTERSINK
CONTRACT(OR)
CONTINUOUS
CONSTRUCTION
CLEAN OUT
CENTER
CONCRETE
COLUMN
CONTROL JOINT
CAST-IN-PLACE
CONC MASONRY UNIT
CLEAR(ANCE)
CLOSET
CAULK
CEILING
CLOSURE
CIRCLE
CG
C/C
CAT
CFT
CHAM
CHT
CB
CAB
CORNER GUARD
CENTER TO CENTER
CUBIC FOOT
CEILING HEIGHT
CAST BASIN
CATEGORY
CHAMFER
CABINET
MANHOLEMH
INVERTINV
FRP FIBERGLASS REINFORCED
PLASTICEJ EXPANSION JOINT
GALVANIZED STEEL SHEET
EQUIP
EXT
EXP
EX
EST
ESC
EWC
ENGR
EQ
ENCL
EMER
ELEV
EL
EP
ELEC
EQUIPMENT
EXPANDED(EXPANSION)
ELECTRIC WATER COOLER
EXTERIOR
EXISTING
ESTIMATE
ESCALATOR
ELECTRICAL POWERBOARD
ENGINEER
EQUAL
ENCLOSE(URE)
EMERGENCY
ELEVATOR
ELEVATION
ELECTRICAL
GKT GASKET(ED)
GP
GYP
GWB
GYPBD
GLAM
GL
GSS
GYPSUM WALL BOARD
GYPSUM BOARD
GLUE LAMINATED
GALVANIZED PIPE
GYPSUM
GLASS
GA
GI
GEN'L
GD
GB
GC
GALV
FURN
FT
FUT
FUR
FS
FTG
FRT
GALVANIZED IRON
GENERAL CONTRACTOR
GALVANIZED
GAUGE
GENERAL
GRADE
GRAB BAR
FURNITURE/FURNISHINGS
FIRE-RETARDANT
FOOT
FUTURE
FURRING
FULL SIZE
FOOTING
JT
KIT
KO
JC
JB
JF
JST
IPS
JOINT
KITCHEN
KNOCKOUT
JANITOR CLOSET
JUNCTION BOX
JOINT FILLER
IRON PIPE SIZE
JOIST
MIR
MISC
MIN
MTD
MO
MM
MT
MASONRY OPENING
MIRROR
MISCELLANEOUS
MILLIMETER
MINIMUM
METAL THRESHOLD
MOUNTED
FIRE-RESISTANT COATING
FIRE EXTINGUISHER CABINET
FINISHED FLOOR ELEVATION
EXTERIOR INSULATION & FINISH
SYSTEM
DISP DISPENSER
EB
EIFS
E
EA
DWR
DR
DN
DWG
DRB
DS
DIV DR
DTL
DL
DP
EXPANSION BOLT
EAST
EACH
DRAWER
DIVISION DOOR
DAMP PROOFING
DOOR
DOWN
DRAWING
DRAIN BOARD
DOWN SPOUT
DETAIL
DEAD LOAD
DEPT
DBL
DF
DH
DIM
DIA
DEP
DEMO
DRINKING FOUNTAIN
DEMOLISH, DEMOLITION
DEPARTMENT
DOUBLE
DIMENSION
DOUBLE HUNG
DIAGONAL
DEPRESSED
FF FACTORY FINISH
FR
FND
FPL
FRC
FP
FOS
FOF
FOM
FOC
FLUOR
FH
FJT
FLR
FLEX
FLG
FFE
FIN
FGL
FRAME(D)(ING)
FOUNDATION
FLOOR PLATE
FACE OF STUDS
FACE OF FINISH
FACE OF MASONRY
FACE OF CONCRETE
FIREPROOF
FLUORESCENT
FIRE HYDRANT
FLUSH JOINT
FIBERGLASS
FLOOR
FLEXIBLE
FLASHING
FINISH(ED)
FBO
FCO
FEC
FE
FA
FAS
FD
FB
FURNISHED BY OTHERS
FLOOR CLEAN OUT
FIRE EXTINGUISHER
FIRE ALARM
FASTEN, FASTENER
FLOOR DRAIN
FACE BRICK
INSULATED BY CONTRACTOR
HEATING/VENTILATING/AIR
CONDITIONING
HP HIGH POINT
INCL
INT
IBC
INFO
ID
INSUL
HR
HWH
HRDW
HWD
HD HT
HTG
HT
HVAC
HOT
WATER
HEATER
INCLUDE(D)(ING)
INFORMATION
INSIDE DIAMETER
INSULATION
INTERIOR
HARDWOOD
HEAD HEIGHT
HOUR
HARDWARE
HEATING
HEIGHT
HM
HB
HOR
HBD
HJT
HDR
HD
HC
HOLLOW METAL
HORIZONTAL
HARDBOARD
HEAD JOINT
HEAVY DUTY
HOLLOW CORE
HOSE BIBB
HEADER
LUMP SUMLS
MED
MEMB
MECH
MAS
MAT'L
MAX
MEP
MTL
MFR
LVR
LVL
MC
M
LT
MATERIAL
MECHANICAL
MEDIUM
MEMBRANE
MAXIMUM
MANUFACTURER
METAL
MASONRY
LOUVER
METER
LIGHT
LAV
LAM
LBL
LAB
LF
LH
LB
LL
LAVATORY
LAMINATE
LINEAR FOOT
LEFT HAND
LABORATORY
LAG BOLT
LIVE LOAD
LABEL
WROUGHT IRON
VINYL ASBESTOS TILE
WELDED WIRE FABRIC
WALL TO WALL
UNDERWRITERS
LABORATORY
UNLESS NOTED OTHERWISE
VAPOR BARRIER
VINYL COMPOSITION TILE
WHEEL BUMPER
WATER REPELLENT
WATERPROOFING
WATER CLOSET
WHB
STANDARDSTD
ROOMRM
PRE CAST CONCRETEPCC
ROUGH OPENING
REVERSE(SIDE)
RIGHT OF WAY
RAIN WATER CONDUCTOR
POLYVINYL CHLORIDE
POUNDS PER CUBIC FOOT
POUNDS PER LINEAL FOOT
POUNDS PER SQUARE FOOT
POINT/PRESSURE TREATED
POUNDS PER SQUARE INCH
PROPERTY LINE/PLATE
PREFABRICATE(D)
PRE FINISHED
PLASTIC LAMINATE
PAIR/PROPOSAL REQUEST
PRELIMINARYPRELIM
PVC
PSF
PT
PSI
PRF
PTN
PVMT
PERFORMED
PARTITION
PAVEMENT
PLF
PLYWD
PREFAB
PNT
PR
POL
PLBG
PNL
PNTD
PLYWOOD
PAINT
POLISHED
PLUMBING
PANEL
PAINTED
PCF
PG
PL
PERIM
PH
PFN
PJ
PLAM
PLAS
PLATE GLASS
PERIMETER
PHASE
PANEL JOINT
PLASTER
RO
ROW
RVS
RWC
TOP OF MASONRY
TONGUE AND GROOVE
TOILET PARTITION
TOILET PAPER DISPENSER
THRES THRESHOLD
TR TRANSOM
TYPICAL
TELEVISION
TYP
TV
TOLERANCE
TOP OF
TOP OF STEEL
TOP OF WALL
TOILET
TOL
TO
TOM
TOS
TOW
TLT
TPTN
TPD
TOWEL BAR
TREAD
THICK(NESS)
TEMPORARY
TERRAZZO
TELEPHONE
TB
T
T&G
THK
TEMP
TER
TEL
SYSTEM
SYNTHETIC
SYMMETRY(ICAL)
SUSPENDED
STRUCTURAL
STORAGE
STEEL
SYS
SYN
SYM
SUS
STR
STOR
STL
WTW
WWF
WI
WSCT
WO
WM
WIN
WTH
WS
WR
WP
WAINSCOT
WITHOUT
WIRED MESH
WINDOW
WIDTH
WATER STOP
RUBBER BASE
REQUEST FOR INFO
ROOF HATCH
REFLECTED CEILING PLAN
REVISION(S),(D)
REFLECT(ED),(ING)
REFRIGERATOR
RAIN LEADER
REINFORCE(D),(ING)
QUARRY TILE
VERTICAL DATUM
NATIONAL GEODETIC
NOT APPLICABLE
NOT IN CONTRACT
OUTSIDE DIAMETER
NOT TO SCALE
OVERFLOW ROOF DRAIN
OPPOSITE HAND
PC
OV
OPP
ORD
OS
PRE CAST
OVERALL
OPPOSITE
OUTSIDE
OC
OFC
OH
OD
OPG
OH/OPH
ON CENTER
OFFICE
OVERHEAD
OPENING
NGVD
N
NA
NIC
NO
NOM
NTS
NORTH
NUMBER
NOMINAL
RADIUSRAD
RFI
RFH
RFG
REV
RES
RET
RH
RFL
RL
ROOFING
RESILIENT
RETURN
RIGHT HAND
REQ'D
RD
RB
RCP
REM
REF
REFR
REG
REINF
REQUIRED
ROOF DRAIN
REMOVE
REFERENCE
REGISTER
RA
R
QTR
QT
RETURN AIR
RISER
QUARTER
SLAB ON GRADE
STAINLESS STEEL
SPECIFICATION(S)
SHELVINGSH
STATION
SQUARE YARD
SQUARE INCH
SQUARE
SPECIAL
SPEAKER
SPACER
STA
SQ/YD
SQ/IN
SS
SQ
SPEC
SPL
SPK
SPCR
SEALER
STEEL JOIST
SHELVING
SOUND PROOF
SLEEVE
SIMILAR
SHEET
SHEATHING
SOG
SLR
SJ
SHELV
SP
SL
SIM
SHT
SHTH
SQUARE FOOT
SOUTH
STORM DRAIN
SOLID CORE
SHEET GLASS
SECTION
SCHEDULE
SAFETY GLASS
SF
S
SD
SC
SG
SECT
SCHED
SFGL
W/
WH
WB
WD
WG
W
WC
WITH
WALL HUNG
WOOD BASE
WOOD
WIRED GLASS
WEST
VAT
VEST
VB
VCT
VAR
VERT
VESTIBULE
VARNISH
VERTICAL
UNF
UR
UL
UNO
UC
UNFINISHED
URINAL
UNDERCUT
OPCI OWNER PROVIDED
CONTRACTOR INSTALLED
OPOI OWNER PROVIDED
OWNER INSTALLED
CPCI CONTRACTOR PROVIDED
CONTRACTOR INSTALLED
RECEP RECEPTIONIST
SECRETARYSECR
SECURITYSECU
AHJ AUTHORITY HAVING JURISDICTION
VOL VOLUME
FV FIELD VERIFIED
UNO
4" TYP
SYMBOL LEGEND
ROOM
NAMEROOM
IDENTIFICATION
A711
MULTIPLE
INTERIOR
ELEVATION
REFERENCE
A1
A3
A2A4
ELEVATION DETAIL NUMBER
ELEVATION ORIENTATION
SHEET NUMBER ON WHICH
ELEVATION OCCURS
FIRST FLOOR
100' - 0"
SPECIALITY
EQUIPMENT
IDENTIFICATION
EQUIPMENT TYPE
(REFER TO EQUIPMENT
SCHEDULE)A
02 4 8134 no.revision
G - General
ID - Interior Design
FS - Food Service
FP - Fire Protection
T - Technology
SCALE:
DATE:
DRAWN BY:
CHECK BY:
PROJECT NUMBER:
1 2 3 4 5 6 7 8 9 10
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ALL REPRODUCTION AND INTELLECTUAL
PROPERTY RIGHTS RESERVED ©
Seal
Consultants
Client
A C CT T SEH IR
605 E. ROBINSON STREET, SUITE 750
ORLANDO, FL 32801
AR0014284
www.rbarchitects.com 407.648.7288
12" = 1'-0"
G001
GENERAL
INFORMATION
LG
MA
05/21/2025
18019
ORANGE COUNTY
ADMINISTRATION
BUILDING BCC
CHAMBERS DAIS
BENCH RENOVATION
ORANGE COUNTY
GOVERNMENT
Permit Documents
GENERAL
REV. NO. SHEET NAME
G000 COVER SHEET
G001 GENERAL INFORMATION
Grand total: 2
ELECTRICAL
REV. NO. SHEET NAME
E001 ELECTRICAL GENERAL NOTES
E101 POWER+LIGHTING+SYSTEMS DEMOLITION PLAN
E102 POWER+LIGHTING+SYSTEMS RENOVATION PLAN
E201 SYSTEMS DETAILS
Grand total: 4
INTERIOR DESIGN
REV. NO. SHEET NAME
ID101 DAIS MILLWORK
Grand total: 1
DATE SUBMISSION/REVISION NO.
ROOM
BCC CHAMBER'S
ID101
A4
REMOVE EXISTING TOP CAP,
EXISTING FRONT FACE PANELING
TO REMAIN
NEW SOLID SURFACE WORK SURFACE
NEW SOLID SURFACE WORK SURFACE
NEW PRESENTATION MONITORS.
COORDINATE SPECS AND DIMENSIONS
WITH OWNER.
NEW CONTINUOUS THIN LED LIGHTING
B4
ID101
B7
ID101
B7
ID101
E7
ID101
E7
ID101
E7
ID101
/4
N E
W H
E
IG
H T
O F
D
IA
S T
O P
S O
L
ID
S U
R F
A C
E T
O P
A N
D F
R O
N T
EXISTING TOP AREA OF NEW WORK, NEW
SOLID SURFACE TOP AND
FRONT, PROVIDE NEW NAME
PLATES PER STATIONS
EXISTING
WOOD VENEER
PANEL FRONT
EXISTING PRE-
DRILLED HOLES
THRU FRAMING
FOR CABLE RUNS
NEW SOLID SURFACE
COUNTER SURFACE
NEW METAL SUPPORT
BRACKETS - WHERE
REQ'D. FOR
COUNTERTOP SUPPORT
PLATFORM, EXISTING
/2
/2
NEW SOLID SURFACE
TOP AND FRONT PANEL
NEW SOLID SURFACE
TRANSACTION, HEAT
MOLDED RADIUS
10"
1' - 4"
NOTCH OUT
FOR LED
DIODE TAPE
LIGHT
FIXTURE
3/4"
RECEPTACLE
NEW FLIP UP POWER
GROMMET, POWER AND USB
/2
0' - 8 3/4"
N E
W D
IA
S
H E
IG
H
T
NEW LED LIGHTING
E X
IS
T
IN
G
D
IA
S H
E
IG
H T
/4
NEW MONITOR
NOTCH AT SOLID SURFACE, P-LAM
INTERIOR FOR MONITOR REST
NEW PLAM BACK PANEL
EXISTING
WOOD VENEER
FRONT PANEL
EXISTING PRE-
DRILLED HOLES
THRU FRAMING
FOR CABLE RUNS
EXISTING PLATFORM/
RAMP /STEP
V A
R
IE
S
P-LAM BACK
PANEL
SOLID SURFACE
TRANSACTION, HEAT
MOLDED RADIUS
1' - 4"
/2
0' - 8 3/4"
EXISTING
WOOD
VENEER
FRONT PANEL
EXISTING PRE-
DRILLED HOLES
THRU FRAMING
FOR CABLE RUNS
SCHEDULED BASE
NEW SOLID SURFACE
COUNTER SURFACE
NEW METAL SUPPORT
BRACKETS - WHERE
REQ'D. FOR
COUNTERTOP SUPPORT
/2
/2
EXISTING PARTITION
RECEPTACLE
NEW BRUSHED BRONZED
RETRACTABLE GROMMET
GROMMET, COORDINATE FINAL
LOCATIONS WITH OWNER
NEW P-LAM
FRONT PANEL
PREFERED, VERIFY IN FIELD
2' - 0"
SCALE:
DATE:
DRAWN BY:
CHECK BY:
PROJECT NUMBER:
1 2 3 4 5 6 7 8 9 10
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ALL REPRODUCTION AND INTELLECTUAL
PROPERTY RIGHTS RESERVED ©
Seal
Consultants
Client
A C CT T SEH IR
605 E. ROBINSON STREET, SUITE 750
ORLANDO, FL 32801
AR0014284
www.rbarchitects.com 407.648.7288
As indicated
ID101
DAIS MILLWORK
LG
MW
05/21/2025
18019
ORANGE COUNTY
ADMINISTRATION
BUILDING BCC
CHAMBERS DAIS
BENCH RENOVATION
ORANGE COUNTY
GOVERNMENT
Permit Documents
SCALE: 1/4" = 1'-0"ID101
A1
FP_01- DAIS RECONFIGURATION
MILLWORK
SCALE: 3/8" = 1'-0"ID101
A4 DAIS ELEVATION
SUBSTITUTIONS
• MATERIALS, PRODUCTS AND EQUIPMENT
SPECIFIED IN CONTRACT DOCUMENTS ESTABLISH
A STANDARD OF QUALITY WITH WHICH PROPOSED
SUBSTITUTIONS MUST COMPLY. REQUESTS FOR
SUBSTITUTIONS SHALL BE SELECTED BY THE
CONTRACTOR AND SUBMITTED TO THE OFFICE OF
THE INTERIOR DESIGNER WITH SPECIFICATIONS
COMPARING SUBSTITUTION WITH THE ORIGINAL
SELECTION. INTERIOR DESIGNER IS NOT
RESPONSIBLE FOR SELECTING ALTERNATE COLOR
AND/OR SPECIFIC MODELS/PATTERNS.
• SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN
THEY ARE INDICATED OR IMPLIED ON SHOP
DRAWINGS OR PRODUCT DATA SUBMITTALS
WITHOUT PRIOR SEPARATE WRITTEN REQUEST OR
WHEN ACCEPTANCE WILL REQUIRE SUBSTANTIAL
REVISION OF CONTRACT DOCUMENTS.
• DESIGNER IS NOT RESPONSIBLE FOR
VERIFICATION OF COMPATIBILITY OF
SUBSTITUTIONS TO OTHER RELATED WORK.
MILLWORK
• ALL MILLWORK DEPICTED HEREIN SHALL COMPLY
WITH STANDARDS FOR CUSTOM GRADE AS
SPECIFIED IN THE CURRENT EDITION OF THE
ARCHITECTURAL WOODWORKER INSTITUTE
STANDARDS.
• MILLWORK SUBCONTRACTOR SHALL SUBMIT SHOP
DRAWINGS FOR APPROVAL TO THE OFFICE OF THE
INTERIOR DESIGNER PRIOR TO ORDERING OF
MATERIALS OR COMMENCEMENT OF WORK.
• ALL ARCHITECTURAL WOODWORK SHALL BE
GUARANTEED TO BE OF GOOD MATERIAL AND
WORKMANSHIP AND FREE FROM DEFECTS THAT
RENDER IT UNSERVICEABLE FOR THE USE FOR
WHICH IT IS INTENDED FOR A PERIOD OF ONE (1)
YEAR AFTER APPROVED FINAL INSTALLATION
DATE.
• ALL ARCHITECTURAL WOODWORK SHALL BE
FACTORY FINISHED WITH TOUCHUP ONLY
OCCURRING IN THE FIELD.
• ALL ARCHITECTURAL WOODWORK OCCURRING AS
WALL PANELING, PILASTERS, SOFFIT CLADDING
SHALL MEET STANDARDS FOR CLASS A (1)
REQUIREMENTS
SOLID SURFACE:
MNF: WILSONART
COLOR: MORNING ICE
PLASTIC LAMINATE:
MNF: WILSONART
COLOR: TO MATCH EXISTING WOOD VENEER PANEL,
PROVIDE SAMPLES FOR ARCHITECT TO VERIFY
SCALE: 1" = 1'-0"ID101
B4 DAIS SECTION
SCALE: 1" = 1'-0"ID101
B7 DAIS SECTION
SCALE: 1" = 1'-0"ID101
E7 DAIS SECTION
DATE SUBMISSION/REVISION NO.
E001
ELECTRICAL GENERAL
NOTES
SCALE:
DATE:
DRAWN BY:
CHECK BY:
PROJECT NUMBER:
1 2 3 4 5 6 7 8 9 10
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ALL REPRODUCTION AND INTELLECTUAL
PROPERTY RIGHTS RESERVED ©
Seal
Consultants
Client
A C CT T SEH IR
605 E. ROBINSON STREET, SUITE 750
ORLANDO, FL 32801
AR0014284
www.rbarchitects.com 407.648.7288
As indicated
ABJr
TM
11/14/25
201 S. ROSALIND AVE
ORLANDO, FL 32801
DATE
11/14/25
SUBMISSION/REVISION
PERMIT DOCUMENTS
NO.
CONSTRUCTION DOCUMENTS
THIS ITEM HAS BEEN
ELECTRONICALLY SIGNED AND
SEALED BY AUGUSTO E. BOBES
JR. P.E. ON THE DATE ADJACENT
TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
A
UG
U S T O E . B O B E S , J R
P R O F E S S I O N A L E N G I N E E R
F L O R I D A
L I C E N S E
ORANGE COUNTY
ADMINISTRATION
BUILDING BCC
CHAMBERS DAIS
BENCH RENOVATION
ORANGE COUNTY
GOVERNMENT
18019
AutoCAD SHX Text
%%UELECTRICAL GENERAL NOTES
AutoCAD SHX Text
1. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 8th EDITION (2023 FBC), THE 2020 NATIONAL ELECTRICAL CODE (NEC), THE CITY OF ORLANDO BUILDING DEPARTMENT, THE CITY OF ORLANDO FIRE MARSHALL, ALL APPLICABLE LOCAL, COUNTY, AND STATE CODES AND STANDARDS, AND ALL REQUIREMENTS OF THE SERVICING ELECTRIC UTILITY. 2. PRIOR TO SUBMITTING THEIR BID FOR THIS WORK, THE CONTRACTOR PRIOR TO SUBMITTING THEIR BID FOR THIS WORK, THE CONTRACTOR SHALL VISIT THE PROJECT JOBSITE AND SHALL FAMILIARIZE THEMSELVES WITH ALL EXISTING BUILDING CONDITIONS, ELECTRICAL SYSTEMS, LOW VOLTAGE SYSTEMS, DEVICES, PANELS ETC. THAT MAY AFFECT THEIR BID. 3. BRANCH WIRING IS NOT SHOWN GRAPHICALLY ON DRAWING AND IS BRANCH WIRING IS NOT SHOWN GRAPHICALLY ON DRAWING AND IS INDICATED BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT. PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT INDICATED GRAPHICALLY. 4. LIGHTING FIXTURES ARE SHOWN FOR QUANTITY AND CIRCUITING ONLY. LIGHTING FIXTURES ARE SHOWN FOR QUANTITY AND CIRCUITING ONLY. FOR EXACT LOCATION OF LIGHTING FIXTURES, REFER TO ARCHITECTURAL DAIS MILLWORK PLANS. COORDINATE WORK WITH MILLWORK CONTRACTOR. PROVIDE PROPER FIXTURE MOUNTING. 5. FOR EXACT ARCHITECTURAL LAYOUT AND DIMENSIONS, COORDINATE FOR EXACT ARCHITECTURAL LAYOUT AND DIMENSIONS, COORDINATE WITH ARCHITECTURAL DRAWINGS. ELECTRICAL DRAWINGS ARE FOR REFERENCE ONLY. 6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE AMERICANS WITH ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA) AND 2020 NATIONAL ELECTRICAL CODE (NEC). 7. COORDINATE ALL WORK DONE UNDER THIS DIVISION WITH WORK TO BE COORDINATE ALL WORK DONE UNDER THIS DIVISION WITH WORK TO BE PERFORMED UNDER THE MECHANICAL DIVISION. 8. COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF ALL COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF ALL MOTORS AND OTHER EQUIPMENT TO BE INSTALLED AND/OR WIRED UNDER THIS DIVISION BUT FURNISHED UNDER ANOTHER DIVISION OF THE SPECIFICATIONS. 9. ALL BRANCH CIRCUITS FOR 120 VOLT, 20 AMP CIRCUITS EXCEEDING ALL BRANCH CIRCUITS FOR 120 VOLT, 20 AMP CIRCUITS EXCEEDING EIGHTY FEET IN LENGTH SHALL BE INCREASED IN SIZE AS REQUIRED TO ALLOW FOR VOLTAGE DROP LOSSES. 10. PACK ALL SLEEVES FOR CONDUITS PASSING THROUGH FIRE RATED PACK ALL SLEEVES FOR CONDUITS PASSING THROUGH FIRE RATED WALLS AND FLOOR SLABS WITH FIRE RESISTANT MATERIALS. ALL PENETRATIONS SHALL BE UL RATED. 11. ALL EMPTY CONDUITS (EC) SHALL BE PROVIDED WITH NYLON PULL ALL EMPTY CONDUITS (EC) SHALL BE PROVIDED WITH NYLON PULL WIRES. 12. TYPE AC CABLE AND ELECTRICAL NON-METALLIC TUBING SHALL NOT TYPE AC CABLE AND ELECTRICAL NON-METALLIC TUBING SHALL NOT BE PERMITTED. TYPE MC CABLE IS PERMITTED AS LONG AS IT IS ACCEPTABLE TO THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ). 13. COORDINATE THE REQUIRED SIZE OF ALL CIRCUIT BREAKERS FEEDING COORDINATE THE REQUIRED SIZE OF ALL CIRCUIT BREAKERS FEEDING EQUIPMENT (I.E. MOTORS, HVAC, KITCHEN EQUIPMENT, SPECIAL PURPOSE OUTLETS, OWNER FURNISHED EQUIPMENT, ETC.) WITH APPROVED EQUIPMENT SHOP DRAWINGS AND OWNER REPRESENTATIVES PRIOR TO ORDERING PANELBOARDS. BREAKERS SHALL BE SIZED PER THE NEC, THE EQUIPMENT NAME PLATE AND MANUFACTURER'S RECOMMENDATIONS. 14. PROVIDE PHENOLIC LABELS ON ALL PANELS AND DISCONNECTS PROVIDE PHENOLIC LABELS ON ALL PANELS AND DISCONNECTS IDENTIFYING WHERE THEY ARE FED FROM. 15. PROVIDE PHENOLIC LABELS ON ALL DISCONNECTS IDENTIFYING THE PROVIDE PHENOLIC LABELS ON ALL DISCONNECTS IDENTIFYING THE ITEM FED BY THE DISCONNECT. 16. THE POWER COMPANY SHALL BE CONTACTED WITHIN 10 DAYS OF THE THE POWER COMPANY SHALL BE CONTACTED WITHIN 10 DAYS OF THE AWARD OF THE CONTRACT BY THE CONTRACTOR TO VERIFY THE ACTUAL AVAILABLE SHORT CIRCUIT FAULT CURRENT (SCC) AT THE TRANSFORMER SECONDARY BUSHINGS. THE CONTRACTOR SHALL PROVIDE ELECTRICAL DISTRIBUTION AND UTILIZATION EQUIPMENT AND PANELBOARDS WHICH HAVE AIC/WITHSTAND RATINGS GREATER THAN THE AVAILABLE SCC. 17. ALL CONDUITS IN OR UNDER SLAB OR UNDERGROUND SHALL BE PVC ALL CONDUITS IN OR UNDER SLAB OR UNDERGROUND SHALL BE PVC SCHEDULE 40. 18. ALL CONDUITS ABOVE SLAB, WHETHER EXPOSED OR CONCEALED, SHALL ALL CONDUITS ABOVE SLAB, WHETHER EXPOSED OR CONCEALED, SHALL BE EMT, IMC, OR RIGID GALVANIZED STEEL. 19. FLEXIBLE METAL RACEWAYS SHALL NOT EXCEED 6' IN LENGTH. FLEXIBLE METAL RACEWAYS SHALL NOT EXCEED 6' IN LENGTH. 20. "LIQUID-TIGHT" TYPE FLEXIBLE WEATHERPROOF RACEWAYS SHALL HAVE "LIQUID-TIGHT" TYPE FLEXIBLE WEATHERPROOF RACEWAYS SHALL HAVE A METALLIC INTERIOR AND NOT EXCEED 6' IN LENGTH. 21. ALL BOXES, PLASTER RINGS, EXTENSION RINGS, AND BOX COVERS ALL BOXES, PLASTER RINGS, EXTENSION RINGS, AND BOX COVERS SHALL BE METAL. 22. ALL CONDUITS SHALL BE PARALLEL AND PERPENDICULAR TO ALL CONDUITS SHALL BE PARALLEL AND PERPENDICULAR TO STRUCTURAL MEMBERS. 23. ALL BENDS SHALL BE MADE IN CONDUIT USING PROPER EQUIPMENT ALL BENDS SHALL BE MADE IN CONDUIT USING PROPER EQUIPMENT AND MEET NATIONAL ELECTRICAL CODE (NEC) REQUIREMENTS. 24. ALL WIRE, INCLUDING BUT NOT LIMITED TO FEEDERS AND BRANCH ALL WIRE, INCLUDING BUT NOT LIMITED TO FEEDERS AND BRANCH CIRCUIT WIRING, SHALL BE COPPER - #12 AWG THWN MINIMUM EXCEPT FOR LOW- VOLTAGE WIRING FOR COMMUNICATIONS SYSTEMS, WHICH MAY BE SMALLER. 25. ALL BREAKERS SHALL BE "FULL SIZE". NO TANDEM, PIGGY BACK, TWIN, ALL BREAKERS SHALL BE "FULL SIZE". NO TANDEM, PIGGY BACK, TWIN, OR HALF SIZE BREAKERS WILL BE ACCEPTED. 26. ALL DEVICES SHALL BE COMMERCIAL OR SPECIFICATION GRADE. ALL DEVICES SHALL BE COMMERCIAL OR SPECIFICATION GRADE. 27. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY POWER AND TEMPORARY LIGHTING DURING CONSTRUCTION. TEMPORARY POWER SHALL PROVIDE ADEQUATE POWER FOR NORMAL CONSTRUCTION USE. TEMPORARY LIGHTING SHALL PROVIDE ADEQUATE LIGHT SO THAT THE INDIVIDUAL TRADES WORK CAN BE COMPLETED. 28. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED. 29. A GREEN INSULATED COPPER GROUND CONDUCTOR SHALL BE A GREEN INSULATED COPPER GROUND CONDUCTOR SHALL BE INSTALLED IN ALL RACEWAYS. 30. GROUNDING SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250 GROUNDING SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250 AND APPLICABLE REQUIREMENTS OF IEEE STANDARDS 142 AND 241. 31. TEST RESISTANCE TO GROUND (EARTHING CONNECTION) WITH TEST RESISTANCE TO GROUND (EARTHING CONNECTION) WITH RESISTANCE TESTER SUBSEQUENT TO FINAL INSTALLATION. WHERE TEST INDICATES RESISTANCE TO GROUND IS OVER 5 OHMS, TAKE APPROPRIATE ACTION TO REDUCE RESISTANCE TO 5 OHMS OR LESS BY DRIVING ADDITIONAL PROPERLY SPACED GROUND RODS AND TREATING SOIL IN PROXIMITY OF GROUND RODS WITH COMMON SALT, COPPER SULFATE OR MAGNESIUM SULFATE. RETEST TO DEMONSTRATE COMPLIANCE. 32. CONDUCTORS ARE SIZED FOR THERMAL CAPACITY PER N.E.C. ARTICLE CONDUCTORS ARE SIZED FOR THERMAL CAPACITY PER N.E.C. ARTICLE 210.19(A)(1) AND VOLTAGE DROP PER ARTICLE 210.19(A) FPN4 AND FBC C405.5.3. ELECTRICAL CONTRACTOR SHALL PERFORM VOLTAGE DROP CALCULATIONS IN ACCORDANCE WITH N.E.C. ARTICLE 210.19 (A) FPN NO. 4 AND F.B.C. C405.5.3 ON ANY CIRCUITS THAT ARE INSTALLED THAT DIFFER FROM THE DESIGN SHOWN IN THESE PLANS. FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 2% AND BRANCH CIRCUIT CONDUCTORS 3% AT DESIGN LOAD. 33. THE CONTRACTOR SHALL PROVIDE A COMPLETE ELECTRICAL SHOP THE CONTRACTOR SHALL PROVIDE A COMPLETE ELECTRICAL SHOP DRAWING SUBMITTAL TO THE ENGINEER FOR REVIEW AND APPROVAL. THE ELECTRICAL SUBMITTAL SHALL INCLUDE ALL ELECTRICAL PANELS, MDP'S, BREAKERS, DISCONNECTS, DEVICES, RECEPTACLES, CONDUIT, RACEWAYS, LIGHT FIXTURES, POLES, SWITCHES, OCCUPANCY SENSORS, PULL BOXES, WIRING ETC. CONTRACTOR SHALL NOT ORDER ANY ELECTRICAL EQUIPMENT UNTIL THIS SUBMITTAL IS REVIEWED AND ACCEPTED BY THE ENGINEER OF RECORD. CONTRACTOR SHALL SUBMIT THE SHOP DRAWING AS ONE COMPLETE SUBMITTAL AND SHALL NOT PIECE MEAL THE SUBMITTAL SPREAD OUT OVER THE COURSE OF DAYS AND WEEKS. FAILURE TO SUBMIT A COMPLETE ELECTRICAL SHOP DRAWING SUBMITTAL SHALL RESULT IN AN IMMEDIATE REJECTION OF THE SHOP DRAWING SUBMITTAL.
AutoCAD SHX Text R,S
AutoCAD SHX Text
XP
AutoCAD SHX Text
EWC
AutoCAD SHX Text
ERM
AutoCAD SHX Text
EWH
AutoCAD SHX Text
ERL
AutoCAD SHX Text
ER
AutoCAD SHX Text
EOLR
AutoCAD SHX Text
NL
AutoCAD SHX Text
PB
AutoCAD SHX Text
PC
AutoCAD SHX Text
MCC
AutoCAD SHX Text
NTS
AutoCAD SHX Text
WP
AutoCAD SHX Text
PT
AutoCAD SHX Text
VP
AutoCAD SHX Text
JB
AutoCAD SHX Text G
AutoCAD SHX Text
VC
AutoCAD SHX Text
AFG
AutoCAD SHX Text
EC
AutoCAD SHX Text
EDH
AutoCAD SHX Text
AFF
AutoCAD SHX Text
CT
AutoCAD SHX Text
EF
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text V
AutoCAD SHX Text
%%UELECTRICAL SYMBOL LIST
AutoCAD SHX Text M
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
TS
AutoCAD SHX Text
FS
AutoCAD SHX Text F
AutoCAD SHX Text
SD
AutoCAD SHX Text F
AutoCAD SHX Text
"FACP"
AutoCAD SHX Text
"FAA"
AutoCAD SHX Text 60A,2P
AutoCAD SHX Text F
AutoCAD SHX Text
FG
AutoCAD SHX Text 30A,3P
AutoCAD SHX Text
II
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text #10
AutoCAD SHX Text
LP-1,3,5
AutoCAD SHX Text #5
AutoCAD SHX Text P
AutoCAD SHX Text
AutoCAD SHX Text D
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text B
AutoCAD SHX Text a
AutoCAD SHX Text p
AutoCAD SHX Text
PC
AutoCAD SHX Text a
AutoCAD SHX Text A
AutoCAD SHX Text b
AutoCAD SHX Text RECESSED 2'x 4' FLUORESCENT FIXTURE. UPPER CASE LETTER LETTER INDICATES FIXTURE TYPE; SUBSCRIPT LETTER INDICATES SWITCH CONTROL.
AutoCAD SHX Text
RECESSED 1' X 4' FLUORESCENT FIXTURE
AutoCAD SHX Text
SURFACE OR PENDANT MOUNTED FLUORESCENT FIXTURE
AutoCAD SHX Text
SURFACE OR PENDANT MOUNTED FLUORESCENT STRIP
AutoCAD SHX Text
WALL MOUNTED FLUORESCENT FIXTURE
AutoCAD SHX Text INCANDESCENT, FLUORESCENT OR HID DOWNLIGHT. UPPER CASE LETTER INDICATED FIXTURE TYPE: SUBSCRIPT LETTER INDICATES SWITCH CONTROL.
AutoCAD SHX Text
WALL MOUNTED EMERGENCY LIGHT
AutoCAD SHX Text
WALL MOUNTED INCANDESCENT, FLUORESCENT OR HID FIXTURE
AutoCAD SHX Text
SURFACE OR PENDANT MOUNTED INCANDESCENT OR H.I.D. FIXTURE
AutoCAD SHX Text
RECESSED INCANDESCENT OR HID WALL WASHER
AutoCAD SHX Text
WALL MOUNTED FLOODLIGHT. ARROW INDICATTES AIMING DIRECTON
AutoCAD SHX Text
REMOTE EMERGENCY BATTERY PACK HEAD
AutoCAD SHX Text
PHOTOCELL
AutoCAD SHX Text
POLE MOUNTED FLOODLIGHT FIXTURE
AutoCAD SHX Text
POLE MOUNTED FIXTURE
AutoCAD SHX Text CEILING MOUNTED EXIT LIGHT. ARROW INDICATES DIRECTIONAL ARROW ON FIXTURE; SHADED AREA INDICATES FACE OF FIXTURE
AutoCAD SHX Text
WALL OR END MOUNTED EXIT LIGHT
AutoCAD SHX Text SINGLE POLE SWITCH, SUBSCRIPT LETTER INDICATES FIXTURE CONTROLLED. (3=3 WAY; 4=4 WAY) MOUNTED 48" AFF
AutoCAD SHX Text SHADED FIXTURE INDICATES PROVIDED WITH BATTERY PACK CONNECTED AHEAD OF ANY SWITCHING.
AutoCAD SHX Text SINGLE POLE SWITCH. p = PILOT LIGHT; k = KEY OPERATED
AutoCAD SHX Text
MOTOR HORSEPOWER RATED TOGGLE SWITCH BY DIVISION 15
AutoCAD SHX Text
MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION
AutoCAD SHX Text
WALL MOUNTED DIMMER. (3 = 3 WAY)
AutoCAD SHX Text
20A 2 POLE 125V GROUNDED SINGLE RECEPTACLE 18"AFF UNLESS OTHERWISE NOTED.
AutoCAD SHX Text 20A, 2 POLE, 125V GROUNDED CONVENIENCE RECEPTACLE. 18" AFF. UNLESS OTHERWISE NOTED.
AutoCAD SHX Text 20A, 2 POLE, 125V GROUNDED DUPLEX CONVENIENCE RECEPTACLE. MOUNTED ABOVE COUNTERTOP UNLESS OTHERWISE NOTED.
AutoCAD SHX Text 20A, 2 POLE, 3 WIRE, 125V GROUNDED DUPLEX RECEPTACLE WITH TOP HALF SWITCHED. 18" AFF. UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
(2) 20A, 2 POLE, 125V GROUNDED CONVENIENCE RECEPTACLE. 18" AFF. UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
(2) 20A, 2P, 3W, 125V GROUNDED DUPLEX RECEPTACLES IN 2-GANG BOX. MOUNTED ABOVE COUNTERTOP, UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
SPECIAL RECEPTACLE AS DESIGNATED ON DRAWINGS
AutoCAD SHX Text CAST IRON FULLY ADJUSTABLE FLOOR BOX WITH ONE 20A, 125V, 2P, 3W DUPLEX RECEPTACLE FLOOR BOX STEEL CITY CAT.#601-P60-CP-P60-DS - COVER PLATE SHALL BE BRASS.
AutoCAD SHX Text
TELEPHONE OUTLET MOUNTED IN FLUSH FLOOR BOX.
AutoCAD SHX Text TELEPHONE WALL OUTLET 18" AFF UNLESS OTHERWISE NOTED P = PAY PHONE OUTLET MOUNTED 48" AFF. PROVIDE 3/4" EC STUB-UP AND TERMINATE 6" ABOVE CEILING. TURN CONDUIT INTO ROOM IT SERVES
AutoCAD SHX Text COMPUTER/TELEPHONE OUTLET BOX 4 11/16"x4 11/16"x2 3/4" DEEP, FLUSH MOUNTED, 18"AFF UNLESS NOTED OTHERWISE, WITH 1"EC STUB-UP 6" ABOVE SUSPENDED CEILING, WITH CONDUIT TURNING INTO ROOM IT SERVES. PROVIDE TRIM RING AS REQUIRED TO ACCOMODATE WALL CONSTRUCTION AND FACEPLATE.
AutoCAD SHX Text COMPUTER OUTLET BOX 4 11/16"x4 11/16"x2 3/4" DEEP, FLUSH MOUNTED 18"AFF UNLESS NOTED OTHERWISE, WITH 1"EC STUB-UP 6" ABOVE SUSPENDED CEILING, WITH CONDUIT TURNING INTO ROOM IT SERVES. PROVIDE TRIM RING RING AS REQUIRED TO ACCOMODATE WALL CONSTRUCTION AND FACEPLATE.
AutoCAD SHX Text TELEVISION OUTLET WITH 1"EC STUB-UP 6" ABOVE SUSPENDED CEILING, WITH CONDUIT TURNED INTO ROOM IT SERVES
AutoCAD SHX Text
CLOCK OUTLET
AutoCAD SHX Text
CLOCK OUTLET WITH CLOCK
AutoCAD SHX Text CONDUIT RUN CONCEALED IN CEILING OR PARTITION. (1/2"C-2#12, 1#12 GND MINIMUM) HALF ARROWHEAD INDICATE CIRCUIT BREAK.
AutoCAD SHX Text CONCEALED BRANCH CIRCUIT WIRING, HASH MARKS INDICATE NUMBER OF CONDUCTORS (GROUND CONDUCTOR NOT SHOWN) TWO CONDUCTORS PLUS GROUND REQUIRED (UNLESS OTHERWISE NOTED). LP-1,3,5 INDICATE HOMERUN TO PANEL BOARD AND CIRCUIT NUMBER DESIGNATION.
AutoCAD SHX Text
CONDUIT RUN BELOW GRADE OR IN SLAB
AutoCAD SHX Text
CONDUIT RUN EXPOSED
AutoCAD SHX Text CONDUIT HOMERUN. HASH MARKS INDICATE NUMBER OF WIRES; NUMBER ADJACENT TO HASH MARKS INDICATE WIRE SIZE
AutoCAD SHX Text
CONDUIT TURNING UP
AutoCAD SHX Text
CONDUIT TURNING DOWN
AutoCAD SHX Text
CEILING MOUNTED JUNCTION BOX
AutoCAD SHX Text
WALL MOUNTED JUNCTION BOX
AutoCAD SHX Text
CEILING MOUNTED SPEAKER
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text CAST IRON FULLY ADJUSTABLE FLOOR BOX WITH ONE MICROPHONE JACK. FLOOR BOX STEEL CITY CAT.#601-P60-CP-P60-DS - COVER PLATE SHALL BE BRASS.
AutoCAD SHX Text WALL MOUNTED OUTLET BOX WITH MICROPHONE JACK AND COVER PLATE MOUNTED 18" AFF UNLESS OTHERWISE NOTED.
AutoCAD SHX Text
CONNECTION TO EQUIPMENT
AutoCAD SHX Text EMERGENCY POWER OFF BREAK GLASS PUSH-BUTTON MOUNT 6'-6" AFF OR AS DIRECTED BY THE FIRE MARSHAL.
AutoCAD SHX Text
MAGNETIC MOTOR STARTER
AutoCAD SHX Text COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT SWITCH. ROMAN NUMERALS INDICATE STARTER SIZE; NUMBERS INDICATE SWITCH OR CIRCUIT BREAKER SIZE
AutoCAD SHX Text
UNFUSED DISCONNECT SWITCH. NUMBERS INDICATE SWITCH SIZE
AutoCAD SHX Text
FUSED DISCONNECT SWITCH. FUSES SIZED AS SHOWN ON DRAWINGS
AutoCAD SHX Text
MOTOR
AutoCAD SHX Text
PANELBOARD, 120/208V, 3 , 4W
AutoCAD SHX Text
TELEPHONE TERMINAL BOARD
AutoCAD SHX Text
FIRE ALARM CONTROL PANEL
AutoCAD SHX Text
FIRE ALARM REMOTE ANNUNCIATOR
AutoCAD SHX Text
METER SOCKET
AutoCAD SHX Text
FLUSH IN-GRADE PULL-BOX
AutoCAD SHX Text
FIRE ALARM MANUAL PULL STATION, MOUNTED 48" AFF
AutoCAD SHX Text
FIRE ALARM SPEAKER WITH STROBE LIGHT, MOUNTED 80" AFF
AutoCAD SHX Text
FIRE ALARM STROBE LIGHT, MOUNTED 80" AFF
AutoCAD SHX Text
FIRE SPRINKLER FLOW SWITCH
AutoCAD SHX Text
FIRE SPRINKLER TAMPER SWITCH
AutoCAD SHX Text
AUTOMATIC HEAT DETECTOR - FIXED TEMPERATURE ONLY
AutoCAD SHX Text
SMOKE DUCT DETECTOR, R=RETURN DUCT, S=SUPPLY DUCT
AutoCAD SHX Text
SMOKE DETECTOR
AutoCAD SHX Text
HEAT DETECTOR
AutoCAD SHX Text
AHU FIRE ALARM SHUTDOWN RELAY
AutoCAD SHX Text
CONTACTOR
AutoCAD SHX Text
TIME CLOCK
AutoCAD SHX Text
GROUND OR GROUND ROD AS NOTED
AutoCAD SHX Text
INFRA-RED SENSOR, FURNISHED AND INSTALLED BY DIV. 15, WIRED BY DIV. 16
AutoCAD SHX Text
SOLENOID VALVE, FURNISHED AND INSTALLED BY DIV. 15, WIRED BY DIV. 16
AutoCAD SHX Text
TRANSFORMER, 120-24 VOLT FURNISHED BY DIV. 15, INSTALLED AND WIRED BY DIV. 16
AutoCAD SHX Text
CEILING MOUNTED SPEAKER AND STROBE
AutoCAD SHX Text
CEILING MOUNTED HORN AND STROBE
AutoCAD SHX Text
ATTENUATOR
AutoCAD SHX Text
ABOVE FINISH FLOOR
AutoCAD SHX Text
ABOVE FINISH GRADE
AutoCAD SHX Text
CURRENT TRANSFORMER
AutoCAD SHX Text
EMPTY CONDUIT
AutoCAD SHX Text
ELECTRIC DUCT HEATER
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
END OF LINE RESISTOR
AutoCAD SHX Text
EXISTING RELOCATED
AutoCAD SHX Text
EXISTING TO BE RELOCATED
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
ELECTRIC WATER HEATER
AutoCAD SHX Text
GROUND FAULT INTERRUPTER
AutoCAD SHX Text
NIGHT LIGHT
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
MOTOR CONTROL CENTER
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
PUSH BUTTON
AutoCAD SHX Text
PULL CHAIN
AutoCAD SHX Text
POTENTIAL TRANSFORMER
AutoCAD SHX Text
VAPOR-PROOF
AutoCAD SHX Text
WEATHERPROOF (NEMA-3R)
AutoCAD SHX Text
EXPLOSION-PROOF
AutoCAD SHX Text DATA OUTLET MOUNTED IN CAST IRON FULLY ADJUSTABLE FLOOR BOX WITH ONE DATA OUTLET. STEEL CITY CAT.#601-P60PCP-P60-DS COVER PLATE SHALL BE BRASS.
AutoCAD SHX Text
SHUNT TRIP
AutoCAD SHX Text
ST
AutoCAD SHX Text
CONDUIT CAPPED OFF
AutoCAD SHX Text
PANELBOARD, 277/480V, 3 , 4W
AutoCAD SHX Text
FIRE ALARM TERMINAL CABINET
AutoCAD SHX Text
"FATC"
AutoCAD SHX Text
FIRE ALARM FLOOR MOUNTED ELECTRO-MAGNETIC DOOR RELEASE
AutoCAD SHX Text
FIRE ALARM WALL MOUNTED ELECTRO-MAGNETIC DOOR RELEASE
AutoCAD SHX Text
%%USCOPE OF WORK
AutoCAD SHX Text THE ELECTRICAL/LOW VOLTAGE SCOPE OF WORK FOR THIS PROJECT INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: 1. REMOVE EXISTING DURESS CALL BUTTONS AND MONITORS ON THE REMOVE EXISTING DURESS CALL BUTTONS AND MONITORS ON THE EXISTING DAIS BENCH. 2. FURNISH AND INSTALL NEW POWER RECEPTACLES, WIRING AND FURNISH AND INSTALL NEW POWER RECEPTACLES, WIRING AND CONDUIT AS INDICATED ON THE RENOVATION PLAN. 3. FURNISH AND INSTALL NEW ABOVE COUNTER LIGHTING WIRING, FURNISH AND INSTALL NEW ABOVE COUNTER LIGHTING WIRING, CONDUIT AND SWITCHES AS INDICATED ON THE RENOVATION PLANS. 4. ROUTE EMPTY CONDUIT FROM EXISTING IDF RACK TO NEW DAIS BENCH ROUTE EMPTY CONDUIT FROM EXISTING IDF RACK TO NEW DAIS BENCH MONITORS. SEE RENOVATION PLANS. ALL DATA CABLING AND DEVICES SHALL BE FURNISHED AND INSTALLED BY OTHERS. 5. FURNISH AND INSTALL NEW UNDER COUNTER DURESS CALL BUTTONS FURNISH AND INSTALL NEW UNDER COUNTER DURESS CALL BUTTONS AS INDICATED ON THE RENOVATION PLAN. SEE RENOVATION PLANS.
AutoCAD SHX Text
WAP
AutoCAD SHX Text
WIRELESS ACCESS POINT
AutoCAD SHX Text
MD
AutoCAD SHX Text
MOTION DETECTOR
AutoCAD SHX Text F
AutoCAD SHX Text
CEILING MOUNTED FIRE ALARM SPEAKER
AutoCAD SHX Text
CR
AutoCAD SHX Text
CARD READER
AutoCAD SHX Text
MD
AutoCAD SHX Text
REQUEST TO EXIT MOTION DETECTOR
AutoCAD SHX Text
DC
AutoCAD SHX Text
DOOR POSITION CONTACT
AutoCAD SHX Text
ES
AutoCAD SHX Text
ELECTRIC STRIKE/LOCKSET
AutoCAD SHX Text
DSCP
AutoCAD SHX Text
DURESS ALARM WIRELESS RECEIVER CONTROL PANEL
AutoCAD SHX Text
RC
AutoCAD SHX Text
DR
AutoCAD SHX Text
UNDERCOUNTER WIRELESS DURESS ALARM TRANSMITTER CALL BUTTON
AutoCAD SHX Text
TX
AutoCAD SHX Text
ACP
AutoCAD SHX Text
ACCESS CONTROL PANEL
AutoCAD SHX Text
ACPS
AutoCAD SHX Text
ACCESS CONTROL POWER SUPPLY
AutoCAD SHX Text
EL
AutoCAD SHX Text
ELECTRIC MORTISE LOCK
AutoCAD SHX Text F
AutoCAD SHX Text
DU
AutoCAD SHX Text
DISCUSSION UNIT SPEAKER/MICROPHONE
AutoCAD SHX Text
FLORIDA STATE P.E. NUMBER: 5131
AutoCAD SHX Text
TELEPHONE: 407.628.0882
AutoCAD SHX Text
150 CIRCLE DRIVE, MAITLAND, FL 32751
AutoCAD SHX Text
E-MAIL: INFO@BOBESENG.COM
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text No 39410
P
E101
POWER + LIGHTING +
SYSTEMS
DEMOLITION PLAN
SCALE: 1/4" = 1'-0"E101
A1 PARTIAL FIRST FLOOR PLAN - POWER+LIGHTING+SYSTEMS - DEMOLITION
SCALE:
DATE:
DRAWN BY:
CHECK BY:
PROJECT NUMBER:
1 2 3 4 5 6 7 8 9 10
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ALL REPRODUCTION AND INTELLECTUAL
PROPERTY RIGHTS RESERVED ©
Seal
Consultants
Client
A C CT T SEH IR
605 E. ROBINSON STREET, SUITE 750
ORLANDO, FL 32801
AR0014284
www.rbarchitects.com 407.648.7288
As indicated
ABJr
TM
09/19/25
201 S. ROSALIND AVE
ORLANDO, FL 32801
DATE
09/19/25
SUBMISSION/REVISION
90% CONSTRUCTION DOCS
NO.
CONSTRUCTION DOCUMENTS
THIS ITEM HAS BEEN
ELECTRONICALLY SIGNED AND
SEALED BY AUGUSTO E. BOBES
JR. P.E. ON THE DATE ADJACENT
TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
A
UG
U S T O E . B O B E S , J R
P R O F E S S I O N A L E N G I N E E R
F L O R I D A
L I C E N S E
ORANGE COUNTY
ADMINISTRATION
BUILDING BCC
CHAMBERS DAIS
BENCH RENOVATION
ORANGE COUNTY
GOVERNMENT
18019
F.E.C.
F.E.C.
F.E.C.
F.H.C.
KEY PLAN
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
SOUND
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
SOUND
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BCC CHAMBERS
AutoCAD SHX Text
AutoCAD SHX Text
MEDIA ROOM
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text 103A
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text
AutoCAD SHX Text
ELEV
AutoCAD SHX Text E01
AutoCAD SHX Text %%uELECTRICAL DEMOLITION KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EXISTING DAIS BENCH TO REMAIN AND BE REFURBISHED/RECONFIGURED. EXISTING MONITOR RECESSED IN MILLWORK TO BE REMOVED. TURN MONITORS OVER TO OWNER FOR DISPOSITION. EXISTING ABOVE COUNTER LIGHTING TO BE REMOVED. CONTRACTOR SHALL REMOVE ALL ASSOCIATED CONDUIT, WIRING AND SWITCHES. EXISTING DURESS CALL BUTTON TO BE REMOVED. EXISTING DURESS ALARM WIRELESS RECEIVER CONTROL PANEL BE REMOVED. DO NOT REMOVE INTEGRATION CIRCUITS WITH ACCESS CONTROL PANEL. REFER TO RENOVATION DRAWINGS FOR ADDITIONAL REQUIREMENTS. FIELD VERIFY EXACT LOCATION. COORDINATE WITH ORANGE COUNTY ISS ENTERPRISE SECURITY PRIOR RIOR TO REMOVAL. EXISTING ACCESS CONTROL PANEL AND POWER SUPPLY SHOWN FOR REFERENCE. COORDINATE DURESS ALARM REMOVAL WITH ORANGE COUNTY ISS ENTERPRISE SECURITY. EXISTING VGA DISTRIBUTION AMPLIFIER TO REMOVED AND REPLACED WITH NEW OWNER FURNISHED 16 OUTPUT VGA AMPLIFIER. EXISTING COUNTER TOP MOUNTED MICROPHONES TO BE REMOVED. CONTRACTOR SHALL REMOVE ALL ASSOCIATED WIRING BACK TO SOURCE. LOCATION OF EXISTING SOUND MIXER BOARD. EXISTING VOICE/DATA COMMUNICATIONS OUTLET AND WIRING TO REMAIN.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING IDF RACK
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
RC
AutoCAD SHX Text
DSCP
AutoCAD SHX Text
AutoCAD SHX Text %%uELECTRICAL DEMOLITION NOTES
AutoCAD SHX Text
1. PRIOR TO THE COMMENCEMENT OF DEMOLITION, THE ELECTRICAL PRIOR TO THE COMMENCEMENT OF DEMOLITION, THE ELECTRICAL CONTRACTOR SHALL MEET WITH THE ORANGE COUNTY PROJECT MANAGER, O.C. ADMINISTRATION BUILDING FACILITIES STAFF AND OC ISS STAFF AT THIS PROJECT SITE AND SHALL IDENTIFY ALL EXISTING ELECTRICAL, LOW VOLTAGE, SOUND AND DURESS SYSTEMS ETC. IN THE DAIS TO BE REMOVED. CONTRACTOR SHALL DETERMINE WHAT, IF ANY OF THE DEVICES SHALL BE TURNED OVER TO THE OWNER. ALL OTHER DEVICES, OUTLETS, CABLING ETC. SHALL BE DISPOSED OF BY THE CONTRACTOR.
AutoCAD SHX Text
VGA AMP
AutoCAD SHX Text
SND MIXER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ACPS
AutoCAD SHX Text
ACP
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLORIDA STATE P.E. NUMBER: 5131
AutoCAD SHX Text
TELEPHONE: 407.628.0882
AutoCAD SHX Text
150 CIRCLE DRIVE, MAITLAND, FL 32751
AutoCAD SHX Text
E-MAIL: INFO@BOBESENG.COM
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text No 39410
AutoCAD SHX Text
EXISTING UNDERCOUNTER POWER AND DATA WIRING TO REMAIN
AutoCAD SHX Text
EXISTING UNDERCOUNTER POWER AND DATA OUTLETS TO REMAIN
AutoCAD SHX Text EXISTING UNDERCOUNTER POWER TO REMAIN AND ABOVE COUNTER LIGHT FIXTURE TO BE REMOVED
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
ATRIUM
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
RR
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
RR
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
PLANS
AutoCAD SHX Text
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MANAGER
AutoCAD SHX Text
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
COPY
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
WAITING
AutoCAD SHX Text 112A
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
IT ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
GENERATOR
AutoCAD SHX Text
AutoCAD SHX Text
SECURITY
AutoCAD SHX Text
AutoCAD SHX Text
RECEIVINF AREA
AutoCAD SHX Text
LOADING
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 183A
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
SERV ELEV
AutoCAD SHX Text 112C
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 190A
AutoCAD SHX Text
RR VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
RR VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
CASHIER
AutoCAD SHX Text
AutoCAD SHX Text
CONTRACTOR
AutoCAD SHX Text
LICENSING
AutoCAD SHX Text
AutoCAD SHX Text
BLDG SAFETY
AutoCAD SHX Text
DIVISION OF
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
PLANS
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
SPECIALIST
AutoCAD SHX Text
ADMIN
AutoCAD SHX Text 130A
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
SOUND
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
SOUND
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BCC CHAMBERS
AutoCAD SHX Text
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
MALE'S
AutoCAD SHX Text 109A
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
FEMALE'S
AutoCAD SHX Text 110A
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
MALE'S
AutoCAD SHX Text 117A
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
FEMALE'S
AutoCAD SHX Text 118A
AutoCAD SHX Text
MEDIA ROOM
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATOR LOBBY
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text 103A
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text S01
AutoCAD SHX Text
CONFERENCE ROOM
AutoCAD SHX Text
BCC CHAMBER'S
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 106A
AutoCAD SHX Text
SPECIALIST
AutoCAD SHX Text
ADMIN
AutoCAD SHX Text 130B
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text 135A
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
STAIR
AutoCAD SHX Text S03
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
SERV
AutoCAD SHX Text E04
AutoCAD SHX Text
MECH
AutoCAD SHX Text 180B
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 180C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 180A
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 112B
AutoCAD SHX Text
ATM ROOM
AutoCAD SHX Text 100B
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
DEPARTMENT
AutoCAD SHX Text
PLANNING & ZONING
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 100A
AutoCAD SHX Text
STAIRS
AutoCAD SHX Text S02
AutoCAD SHX Text
ELEV
AutoCAD SHX Text E02
AutoCAD SHX Text
ELEV
AutoCAD SHX Text E03
AutoCAD SHX Text
ELEV
AutoCAD SHX Text E01
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BREAK
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
AREA
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text
AutoCAD SHX Text
LEADER TEXT-120
AutoCAD SHX Text
EXISTING DAIS TO REMAIN AND BE REFURBISHED
EXISTING UNDERCOUNTER POWER AND DATA OUTLETS TO BE REMAIN
E102
POWER + LIGHTING +
SYSTEMS RENOVATION
PLAN
SCALE:
DATE:
DRAWN BY:
CHECK BY:
PROJECT NUMBER:
1 2 3 4 5 6 7 8 9 10
H
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
ALL REPRODUCTION AND INTELLECTUAL
PROPERTY RIGHTS RESERVED ©
Seal
Consultants
Client
A C CT T SEH IR
605 E. ROBINSON STREET, SUITE 750
ORLANDO, FL 32801
AR0014284
www.rbarchitects.com 407.648.7288
As indicated
ABJr
TM
11/14/25
201 S. ROSALIND AVE
ORLANDO, FL 32801
DATE
11/14/25
SUBMISSION/REVISION
PERMIT DOCUMENTS
NO.
CONSTRUCTION DOCUMENTS
THIS ITEM HAS BEEN
ELECTRONICALLY SIGNED AND
SEALED BY AUGUSTO E. BOBES
JR. P.E. ON THE DATE ADJACENT
TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE SIGNATURE
MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
A
UG
U S T O E . B O B E S , J R
P R O F E S S I O N A L E N G I N E E R
F L O R I D A
L I C E N S E
ORANGE COUNTY
ADMINISTRATION
BUILDING BCC
CHAMBERS DAIS
BENCH RENOVATION
ORANGE COUNTY
GOVERNMENT
18019
SCALE: 1/4" = 1'-0"E102
A1 PARTIAL FIRST FLOOR PLAN - LIGHTING - RENOVATION
SCALE: 1/4" = 1'-0"E102
A2 PARTIAL FIRST FLOOR PLAN - POWER - RENOVATION
SCALE: 1/4" = 1'-0"E102
A4 PARTIAL FIRST FLOOR PLAN - SYSTEMS - RENOVATION
F.E.C.
F.E.C.
F.E.C.
F.H.C.
KEY PLAN
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BCC CHAMBERS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text 3a
AutoCAD SHX Text 3b
AutoCAD SHX Text LI5-45b
AutoCAD SHX Text LI5-45a
AutoCAD SHX Text %%uLIGHTING KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW ABOVE COUNTER LED LIGHTING STRIP. CONNECT TO EXISTING LOCAL CIRCUIT. SEE MILLWORK SECTION FOR EXACT LOCATION AND MOUNTING. NEW DIODE TAPE LIGHT FIXTURE IN NOTCH OUT. SEE MILLWORK DRAWINGS FOR EXACT LOCATION.
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BCC CHAMBERS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
LI5-65
AutoCAD SHX Text
LI5-67
AutoCAD SHX Text
LI5-67
AutoCAD SHX Text
LI5-67
AutoCAD SHX Text
LI5-67
AutoCAD SHX Text
LI5-67
AutoCAD SHX Text
LI5-65
AutoCAD SHX Text
LI5-65
AutoCAD SHX Text
LI5-65
AutoCAD SHX Text
LI5-65
AutoCAD SHX Text %%uPOWER KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text NEW ABOVE COUNTER RECEPTACLE WITH USB AND USB-C CONNECTIONS. CONNECT TO EXISTING LOCAL CIRCUIT. SEE MILLWORK DRAWINGS FOR EXACT LOCATION.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
BCC CHAMBERS
AutoCAD SHX Text
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text
DR
AutoCAD SHX Text
TX
AutoCAD SHX Text %%uSYSTEMS KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text PROVIDE UNDERCOUNTER MOUNTED WIRELESS DURESS ALARM CALL BUTTON. COORDINATE WITH ARCHITECT AND ORANGE COUNTY SECURITY PRIOR TO INSTALLATION. NEW WIRELESS DURESS RECEIVER. PROVIDE ALL REQUIRED INPUT CONNECTIONS TO EXISTING ACCESS CONTROL INPUT/OUTPUT MODULE. ALL DURESS ALARM TRANSMITTER BUTTONS SHALL HAVE A DEDICATED INPUT ON THE ACCESS CONTROL. COORDINATE WITH ORANGE COUNTY SECURITY. REFER TO DURESS ALARM ONE LINE DIAGRAM FOR ADDITIONAL INFORMATION. EXISTING ACCESS CONTROL PANEL AND POWER SUPPLY SHOWN FOR REFERENCE. COORDINATE NEW DURESS ALARM INSTALLATION WITH ORANGE COUNTY ISS ENTERPRISE SECURITY. NEW OWNER FURNISHED CONTRACTOR INSTALLED 16 OUTPUT VGA DISTRIBUTION AMPLIFIER. REFER TO VGA SIGNAL DISTRIBUTION ONE LINE DIAGRAM. PROVIDE (6), PLENUM RATED RGB 25 AWG. SVGA VIDEO CABLES. RUN CABLES FROM VGA DISTRIBUTION AMPLIFIER TO NEW COMPUTER MONITOR LOCATIONS INSTALLED IN DAIS. PROVIDE HD15 VGA CONNECTORS AT EACH END. REWORK ROUTING OF EXISTING VGA CABLES TO REMAINING COMPUTER MONITORS INSTALLED. NEW VGA MONITORS ARE OWNER FURNISHED CONTRACTOR INSTALLED. COORDINATE WITH ARCHITECTURAL DRAWINGS. PROVIDE DISCUSSION SYSTEM CONTROLLER. INSTALL UNIT IN THE EXISTING MILLWORK HOUSING THE EXISTING AUDIO EQUIPMENT. REFER TO DISCUSSION SYSTEM ONE LINE DIAGRAM. PROVIDE COUNTER TOP MOUNTED DISCUSSION UNIT WITH INTEGRAL SPEAKER AND 18" GOOSENECK MICROPHONE. (TYPICAL)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VGA AMP
AutoCAD SHX Text
SND MIXER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DSCP
AutoCAD SHX Text
ACPS
AutoCAD SHX Text
ACP
AutoCAD SHX Text
RC
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DU
AutoCAD SHX Text
DISCUSSION CONT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FLORIDA STATE P.E. NUMBER: 5131
AutoCAD SHX Text
TELEPHONE: 407.628.0882
AutoCAD SHX Text
150 CIRCLE DRIVE, MAITLAND, FL 32751
AutoCAD SHX Text
E-MAIL: INFO@BOBESENG.COM
AutoCAD SHX Text
STATE OF
AutoCAD SHX Text No 39410
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
ATRIUM
AutoCAD SHX Text
AutoCAD SHX Text
LOBBY
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
RR
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
RR
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
TELEPHONE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OPEN
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
PLAN…