FIRE RESCUE EMERGENCY OPERATION CENTER RENOVATION
Solicitation number
Y22-795-TA
Issued by
Orange County, Orlando City, Florida

About this file

The document is a comprehensive set of architectural and engineering drawings for the Orange County Government Fire Rescue Emergency Operations Center interior renovation project located at 6590 Amory Court in Winter Park, Florida. The project involves interior alterations, technology upgrades, electrical and mechanical modifications, and renovating the building entry area for the Emergency Operations Center. The scope of work includes reconfiguring multiple rooms such as the Emergency Operations Center, Message Center, GIS Center, IT/Control Room, Conference Rooms, and various support spaces. The drawings are dated July 7, 2021, and include detailed plans for demolition, architectural modifications, audiovisual systems, electrical, mechanical, and fire protection systems.

The renovation encompasses approximately 2,352 square feet and maintains the existing building's occupancy type and construction type. The project documents specify compliance with the 2020 Florida Building Code, including accessibility requirements. The architectural drawings feature detailed specifications for new partitions, finishes, furniture, and technology infrastructure, with a focus on creating a flexible, modern workspace for emergency operations personnel. The audiovisual plans include comprehensive integration of display systems, cameras, microphones, and networking equipment across multiple rooms, suggesting a sophisticated communication and coordination environment. While no specific budget is mentioned in the drawings, the level of technical detail and comprehensive systems integration indicates a significant investment in modernizing the county's emergency response capabilities.

View the file

Other files

File Type Posted
Y22-795-TA_Specs.pdf PDF
Y22-795-TA_BID_DOCUMENTS.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fire Rescue - EOC Orange County Government 6590 Amory Court Winter Park, FL 32792

KMF Architects

839 N. Magnolia Ave.

Orlando, FL 32803 407.298.1988

LIC # AR 93580

SGM Engineering

935 Lake Baldwin Lane Orlando, FL 32814 407.767.5188

ELECTRICALARCHITECTURE

VICINITY MAP

10-22-30-8821-00-020

PARCEL ID NUMBER

PROJECT LOCATION

SHEET ISSUE

COVER SHEET,

DRAWING INDEX

AND VICINITY

PLAN

01G.000

SHEET TITLESHEET

G.000 COVER SHEET, DRAWING INDEX AND VICINITY PLAN

OVERALL FLOOR PLANA.100

G.010

2021.07.07

DRAWING INDEX

G.012

ISSUE NO. DATE

E.001 ELECTRICAL SYMBOLS LEGEND

ED.101 PARTIAL DEMO. PLAN

ED.111

E L E C T R I C A LA R C H I T E C T U R A L

ACCESSIBILITY DETAILS

ACCESSIBILITY DETAILS

LEVEL 2 INTERIOR ALTERATIONS

6590 AMORY COURT WINTER PARK, FLORIDA, 32792

ORANGE COUNTY GOVERNMENT,

FIRE RESCUE EMERGENCY OPERATIONS CENTER

CODES IN EFFECT:

SCOPE OF PROJECT:

ADDRESS:

PROJECT:

CARL SHEA; KMF ARCHITECTS, 407.298.1988ARCHITECT CONTACT:

THE SCOPE OF WORK FOR THIS PROJECT IS INTERIOR ALTERATIONS INCLUDING TECHNOLOGY UPGRADES AND

ASSOCIATED ELECTRICAL AND MECHANICAL, AND RENOVATED BUILDING ENTRY AREA

THE OCCUPANCY TYPE, CONSTRUCTION TYPE AND BUILDING AREA WILL NOT CHANGE AS A RESULT OF THESE

ALTERATIONS.

THE INFORMATION CONTAINED BELOW REFERS TO THE OVERALL, EXISTING BUILDING, AND IS FOR INFORMATIVE

PURPOSES. ONLY AS IT IS KNOWN AND AS PRESENTED TO THE ARCHITECT BY THE OWNER.

A.J. MURRAY- CAPITAL PROJECTS DIVISION - ORLANDO, FL 32801

TEL. 407.836.0050

COUNTY PROJECT MANAGER:

- FLORIDA BUILDING CODE, BUILDING, 7TH EDITION

- FLORIDA EXISTING BUILDING CODE, 7TH EDITION

- FLORIDA BUILDING CODE, ACCESSIBILITY, 7TH EDITION

- FLORIDA FIRE PREVENTION CODE, 7TH EDITION (ADOPTED DECEMBER 31, 2020)

PARTIAL FLOOR PLANA.101

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

KMFARCHITECTS.COM

407.298.1988

FI

R E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

PARTIAL DEMOLITION PLANAD.101

M.001 MECHANICAL SYMBOLS LEGEND

M E C H A N I C A L

F.001 FIRE PROTECTION SYMBOLS LEGEND

F I R E P R O T E C T I O N

Thorburn Associates Inc.

7780 Chapel Hill Drive Orlando, FL 32819 407.898.5645

TECHNOLOGY

G.100 PARTITION TYPES

PARTIAL REFLECTED CEILING PLANA.111

INTERIOR ELEVATIONSA.401

DOOR SCHEDULE & DETAILSA.601

PARTIAL DEMO REFLECTED CEILING PLAN

E.101 PARTIAL PLAN

E.111 PARTIAL REFLECTED CEILING PLAN

ES.001 SYSTEMS SYMBOLS LEGEND

ESD.101 PARTIAL DEMO. PLAN

ES.101 PARTIAL PLAN

M.002 MECHANICAL GENERAL NOTES

MD.101 PARTIAL DEMO. PLAN

M.101 PARTIAL PLAN

M.801 DETAILS

PARTIAL DEMO. REFLECTED CEILING PLANAD.111

ACCESS FLOOR PLANA.102

INTERIOR ELEVATIONSA.402

INTERIOR ELEVATIONSA.403

INTERIOR ELEVATIONSA.404

LIFE SAFETY PLANLS.101

DEMO ELEVATIONSAD.401

BASE Consultants

1214 E. Concord Street Orlando, FL 32803 407.377.7227

STRUCTURAL

EOC FURNITURE PLANI.201

MILLWORK SECTIONSA.406

SHEET TITLESHEET

DRAWING INDEX

ISSUE NO. DATE

TA.101 AV FLOOR PLAN

T E C H N O L O G Y

FLOOR AND WALL SYSTEM DETAILSA.340

S.101 STRUCTURAL NOTES AND DETAILS

S T R U C T U R A L

TA.301 SECTIONS AND ELEVATIONS

TA.302 SECTIONS AND ELEVATIONS

TA.501 RACK DETAILS AND ELEVATIONS

FINISH PLANI.101

DETAILSA.602

E.801 DETAILS

ES.801 DETAILS

M.701 SCHEDULES

F.101 PARTIAL PLAN

F.801 DETAILS

ENLARGED FLOOR PLANSA.351

FD.101 PARTIAL DEMO. PLAN

ERIC KLEINSTEUBER; KMF ARCHITECTS, 407. 298.1988ARCHITECT OF RECORD:

Orange County Capital Projects Division 400 E. South St., 5th Floor Orlando, FL 32801 407.836.0050

OWNER CONTACT

E.701 SCHEDULES 01

ES.501 RISER DIAGRAMS 01

TA.201 AV REFLECTED CEILING PLAN 01

TA.002 SCHEDULES

TA.003 RISER DIAGRAMS

DEMO ELEVATIONSAD.402 01

FLOOR AND WALL SYSTEM DETAILSA.341 01

Carlsson Construction Estimators Inc.

1000 Savage Court, Suite 104 Longwood, FL 32750 407.792.9988

Cost Estimating

DETAILSA.603 01

INTERIOR FINISHESI.102 01

INTERIOR FINISHESI.103 01

INTERIOR FINISHES & MEDIA WALL PANEL MATRIXI.104 01

01TA.001 SHEET INDEX AND NOTES

TA.400 FUNCTIONALS 01

TA.401 FUNCTIONALS 01

TA.601 INTERFACE PLATES 01

TA.701 COORDINATION DETAILS 01

Orange County Government Mayor - Jerry Demings Commissioner - Emily Bonilla Chief James Fitzgerald Chief John Westmoreland Chief Michael Wajda

TA.402 FUNCTIONALS 01

TA.403 FUNCTIONALS 01

TA.404 FUNCTIONALS 01

REPLACE ENTRY CURTAIN WALL ADD ALTERNATEA.800 01

* ISSUED AS PART OF ADD ALTERNATE

REFLECTED CEILING DIMENSION PLANA.112 01

TA.702 COORDINATION DETAILS 01

2021.07.07 2021.07.07 2021.07.07

2021.07.07

2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07

2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07

2021.07.07 2021.07.07 2021.07.07

2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07

2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07

2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07 2021.07.07

G.200 UL DETAILS 01 2021.07.07

m in

24 min m in

36 min

12 min 12 min

60 min base ar ar

17-25

6 max m in

(a) elevation

(b) plan

11 min m in

8 min

9 min

(a) elevation

(b) plan m in

25 max

4 max

X ³

X m ax X m in m ax m ax m ax

>20-25 max20 max

(a) (b)

10 max m ax m in

LC

min max dimension showing English units above the line (in inches unless otherwise specified) dimension for small measurements (in inches unless otherwise specified) direction of travel or approach boundary of clear floor space or maneuvering clearance centerline minimum maximum a permitted element or its extension a wall, floor, ceiling or other element cut in section or plan a highlighted element in elevation or plan

CONVENTION DESCRIPTION

location zone of element, control or feature greater than>

< less than

33-36 dimension showing a range with minimum -maximum (in inches unless otherwise specified) less than or equal to greater than or equal to>

10 max m ax m ax m ax m ax

> 10-24 max

(a) (b) m in

48 min

24 max m in m in m in

24 max

18 min

18 min45° centered on tactile charactersLC m in

MEN not in pictogram field

AREA OF

REFUGE

3/8 min

3/8 min

LIBRARY

/8 m in m ax m ax at lavatory or counter m ax not at lavatory or counter full height (preferred)

Dimensions shown are from finished floor to bottom of reflective surface, unless noted otherwise m in (f in . f lr.

to to p ed ge

REFUGE

AREA OF

AREA OF

REFUGE

m in m ax

CHANGES IN LEVEL

NOTES REGARDING THE IMAGES SHOWN ON SHEETS A.010,

A.011 AND A.012:

1. ALL DETAILS REFERENCED ON THIS SHEET ARE TAKEN FROM

THE FLORIDA ACCESSIBILITY CODE 7th EDITION (2020) AND

APPLY TO ALL SHEETS, DRAWINGS AND DETAILS WITHIN

THESE CONSTRUCTION DOCUMENTS, WHETHER

SPECIFICALLY NOTED OR NOT

2. ALL DETAILS SHOWN ON THIS SHEET MAY NOT BE

APPLICABLE TO ALL PROJECTS

3. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS, NEW AND

EXISTING

4. ANY AND ALL DISCREPANCIES AND/OR QUESTIONS SHALL BE

PRESENTED TO THE ARCHITECT IN WRITING

TOE CLEARANCE

KNEE CLEARANCE

VERTICAL CLEARANCE

NOTESOBSTRUCTED HIGH FORWARD REACH

GRAPHIC CONVENTION FIGURE KEY

21 T-SHAPED TURNING SPACE

OBSTRUCTED HIGH SIDE REACH

CLEAR WIDTH OF AN ACCESSIBLE ROUTE

PICTOGRAM FIELD

HEIGHT OF RAISED CHARACTERS

POSITION OF BRAILLE

MIRRORS

1/2" max

CARPET PILE

HEIGHT

1/4"

VERTICAL

CHANGE IN

LEVEL

1/4"

1/4"

1/2"

BEVELED

CHANGE IN

LEVEL

UNOBSTRUCTED

SIDE REACH

UNOBSTRUCTED

FORWARD REACH

HEIGHT OF TACTILE CHARACTERS ABOVE

FINISH FLOOR OR GROUND

15LOCATION OF TACTILE

SIGNS AT DOORS

LIMITS OF PROTRUDING

OBJECTS

EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2 inch (13 mm) minimum.

m ax m ax

INSTALL HEGIHT FOR SWITCHES,

KEY READERS, AND THERMOSTATS 17

distance between corresponding dots in adjacent cells distance between dots in the same cell distance between corresponding from one cell directly below distance between dots in the same cell single braille cell blank cell space between words base diameter raised dot

Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text. Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements.

19BRAILLE DIMENSIONS

no raised dot

MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES

Dot base diameter

Distance between two dots in the same cell

Distance between corresponding dots in adjacent cells

Dot height

Distance between corresponding dots from one cell directly below

0.059 (1.5 mm) to 0.063 (1.6 mm)

0.090 (2.3 mm) to 0.100 (2.5 mm)

0.241 (6.1 mm) to 0.300 (7.6 mm)

0.025 (0.6 mm) to 0.037 (0.9 mm)

0.395 (10 mm) to 0.400 (10.2 mm)

SHEET ISSUE

ACCESSIBILITY

DETAILS

01G.010

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

42 min m in

X < 48

42 min

X < 48

36 min 36 min m in

(a) 180 degree turn

(b) 180 degree turn (Exception)

(c) folding door

(a) hinged door

(b) sliding door

32 min

32 min

32 min m in

18 min

(a) front approach, pull side m in

(b) front approach, push side m in12 min

(c) front approach, push side, door provided with both closer and latch

36 min 60 m in

(d) hinge approach, pull side

42 min 54 m in

(e) hinge approach, pull side m in

22 min

(f) hinge approach, push side

(g) hinge approach, push side, door provided with both closer and latch m in

22 min

24 min m in

(h) latch approach, pull side

(i) latch approach, pull side, door provided with closer m in

24 min

24 min m in

(j) latch approach, push side

(k) latch approach, push side, door provided with closer

24 min m in m in

(a) front approach

(b) side approach m in

22 min m in

(c) pocket or hinge approach

24 min m in

(d) stop or latch approach

48 min 48 min

(a) (b)

48 min

(c)

0104 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATESMANEUVERING CLEARANCES AT RECESSED DOORS AND GATES

CLEAR WIDTH AT TURN CLEAR WIDTH OF DOORWAYS

MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS m in

18 min

X > 8

(a) pull side m in

(b) push side

X > 8 m in

12 min

(c) push side, door provided with both closer and latch

X > 8

DOORS IN SEQUENCE

SHEET ISSUE

ACCESSIBILITY

DETAILS

01G.012

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

NOTE:

THIS PARTITION OFTEN OCCURS IN MIRRORED PAIRS, FORMING

PLUMBING CHASES OR ARCHITECTURAL ELEMENTS. SEE THE PLANS

FOR DIMENSIONS OF SEPARATION.

STC RATED PARTITION CONSTRUCTED SOUND TESTED PER RAL-TL90-166

(THIS PARTITION IS NOT "FIRE RATED" FOR EGRESS)

GENERAL NOTES FOR ALL PARTITION TYPES:

1. KMF ARCHITECTS TYPICAL PARTITION TYPES

SHOWN. ALL PARTITIONS MAY NOT OCCUR

ON EVERY PROJECT. REFER TO PLAN AND

SECTION SHEETS.

2. SEE UL DETAILS INCLUDED AND OR

REFERENCED FOR FIRE RATED ASSEMBLY

REQUIREMENTS.

3. USE TILE BACKER BOARD BEHIND ALL TILE

WALLS & CEILINGS.

4. GYPSUM FINISH:

(UNLESS OTHERWISE NOTED)

LEVEL 5 TYP. @ ALL SPACES

LEVEL 4 TYP. @ STORAGE SPACES

LEVEL 3 TYP. @ MECHANICAL &

ELECTRICAL SPACES

5. PAINT ONE COAT TINTED PRIMER, TWO TOP

COATS MINIMUM. SEE SPECIFICATIONS.

6. ALL RATED PARTITIONS WITH INTERSECTING

CEILINGS & PARTITIONS IN OPEN STORAGE,

MECHANICAL & ELECTRICAL ROOMS SHALL

BE STENCILED PER CODE, INCLUDING FIRE

RATING, AND PROTECT ALL OPENINGS.

CEILING

HEAD

FILL FLUTES WITH SOUND ATTENUATION

BLANKETS OR MINERAL WOOL

CONT. STEEL CHANNEL TRACK, (20 GA MIN)

3 1/2" BATT INSULATION

SOUND ATTENUATION BATTS FULL HEIGHT OF WALL

5/8" GYP. BOARD ONE SIDE, FINISH AS SCHEDULED.

METAL RUNNER (20 GAUGE MIN.)

ANCHOR @ 24" O.C. MAX.

BASE AS SCHEDULED

METAL RUNNER (20 GAUGE MIN) ANCHOR

@ 24" O.C. MAX.

BASE EACH SIDE AS SCHEDULED.

CEILING AS SCHEDULED

5/8" GYP. BD. EACH SIDE, FINISH AS SCHEDULED

UNDERSIDE OF STRUCTURE.

CEILING

BASE

HEAD

METAL RUNNER (20 GAUGE MIN)

ANCHOR @ 24" O.C. MAX.

CONTINUOUS SEALANT EACH SIDE

5/8" GYP. BD. EACH SIDE, FINISH AS

SCHEDULED.

UNDERSIDE OF STRUCTURE.

BRACE TO STRUCTURE ABOVE @ 4'

O.C. STAGGER BRACES SIDE TO SIDE.

METAL RUNNER (20 GA. MIN.)

CEILING AS SCHEDULED

CEILING/HEAD

PLAN

BASE

BASE EACH SIDE AS SCHEDULED.

METAL RUNNER (20 GAUGE MIN).

ANCHOR @ 24" O.C. MAX.

CEILING

BASE

CEILING AS SCHEDULED

UNDERSIDE OF STRUCTURE ABOVE

PROVIDE INSULATION BATTS CONTINUOUS TO

UNDERSIDE OF STRUCTURE ABOVE

3 5/8" METAL STUDS (20 GA. MIN)

AT CEILING

UNDERSIDE OF STRUCTURE

CONT. STEEL CHANNEL TRACK, (20 GA MIN)

CEILING AS SCHEDULED

CONT. HORIZONTAL STUD BRACING AT CEILING

HEIGHT (20 GA. MIN)

METAL RUNNER (20 GAUGE MIN)

ANCHOR @ 24" O.C. MAX.

BASE AS SCHEDULED

BRACE TO STRUCTURE ABOVE @ 4' O.C.

STAGGER BRACES SIDE TO SIDE.

5/8" GYP. BOARD, FINISH AS SCHEDULED.

4" M

IN

HEAD

CEILING

I N T E R I O R R O O M S I D E

S H A F T

UNDERSIDE OF STRUCTURE

METAL RUNNER (20 GAUGE MIN)

ANCHOR @ 24" O.C. MAX.

PROVIDE FIRE-RATED HEAD OF WALL DETAIL AT

INTERSECTION WITH STRUCTURE ABOVE

CEILING AS SCHEDULED

PROVIDE FIRE-RATED BOTTOM OF WALL DETAIL AT

WALL INTERSECTION WITH STRUCTURE.

BASE AS SCHEDULED

(1) LAYER 1" TYPE "X" GYPSUM SHAFT SIDE

METAL RUNNER (20 GAUGE MIN) ANCHOR

@ 24" O.C. MAX.

CEILING

UNDERSIDE OF STRUCTURE

FILL FLUTES WITH SOUND ATTENUATION BLANKETS

OR MINERAL WOOL

METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.

MAX.

3 1/2" BATT INSULATION, BOTH SIDES OF PARTITION

CEILING AS SCHEDULED

METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.

MAX.

BASE EACH SIDE AS SCHEDULED

CONT. ACOUSTICAL SEALANT

5/8" TYPE C GYP. BOARD OVER 25 GA.

RESILIENT FURRING CHANNELS INSTALLED

HORIZONTALLY @ 24" O.C.

METAL RUNNER (20 GA. MIN.)ANCHOR

@ 24" O.C. MAX.

FILL IN FLUTES WITH FIRE SAFING; APPLY SMOKE

SEALANT. (PER UL HEAD OF WALL REQUIREMENT)

UNDERSIDE OF STRUCTURE.

5/8" TYPE 'X' GYPSUM BOARD EACH

SIDE OF METAL STUDS

CEILING AS SCHEDULED

FIRESTOP SEALANT

METAL RUNNER (20 GAUGE MIN.)

ANCHOR @ 24" O.C. MAX.

HEAD

BASE

4" M

IN

CONT. HORIZONTAL STUD BRACING AT CEILING

HEIGHT (20 GA. MIN)

CEILING AS SCHEDULED

CONT. HORIZONTAL STUD BRACING AT CEILING

HEIGHT (20 GA. MIN)

2'-0" TYP.

BASE EACH SIDE AS SCHEDULED

FIRE STOP SEALANT BOTH SIDES

METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24" O.C.

MAX.

BASE

BASE

BASE

BASE

2'-0"

TYP.

NOTE:

THIS PARTITION OFTEN OCCURS IN MIRRORED PAIRS,

FORMING PLUMBING CHASES OR ARCHITECTURAL ELEMENTS.

SEE THE PLANS FOR DIMENSIONS OF SEPARATION.

EXTEND FIRE RATING TO UNDERSIDE

OF STRUCTURE

BASE EACH SIDE AS SCHEDULED

PLAN

PLAN

SOUND ATTENUATION BATTS FULL

HEIGHT OF WALL

PLAN

2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE

OF METAL STUDS

3-5/8'' 20 GAGE METAL STUDS @ 16" O.C.

CEILING

HEAD

PLAN

3 5/8" STEEL STUDS (20 GA. MIN) @ 16" O.C. MAX.

DOUBLE STUDS AT ALL WALL HUNG MILLWORK,

TOILET PARTITIONS & ACCESSORIES, CASE

WORK & EQUIPMENT.

SHEET METAL BLOCKING (12 GA. MIN) SIZED

2" LARGER EACH DIRECTION THAN DIM. OF

WALL HUNG EQUIPMENT

CEILING/HEAD

3 5/8" STEEL STUDS (20 GA. MIN) AT 16" O.C. MAX.

DOUBLE STUDS AT ALL WALL HUNG MILLWORK,

TOILET PARTITIONS & ACCESSORIES,CASE WORK

& EQUIPMENT

SHEET METAL BLOCKING (12 GA. MIN) SIZED 2"

LARGER EACH DIRECTION THAN DIM. OF WALL

HUNG DEVICE

PLAN

PLAN

5/8" TYPE 'X' GWB ONE SIDE

2-1/2" C-H STUDS, PROVIDE GAUGE AS REQUIRED

FOR CONDITIONS WHERE INSTALLED

1-1/2" BATT INSULATION

PLAN

3 5/8" STEEL STUDS (20 GA. MIN.) @ 24" O.C.

3 1/2" SOUND ATTENUATION BATTS

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK, AND EQUIPMENT.

SEAL PENETRATIONS AT MILLWORK.

HEAD2'-0"

TYP.

METAL RUNNER (20 GAUGE MIN.)

ANCHOR @ 24" O.C. MAX.

BASE EACH SIDE AS SCHEDULED.

2 1/2" METAL STUDS (20 GA. MIN) AT

16" OC MAX.

CEILING AS SCHEDULED

5/8" GYP. BD. FINISH AS SCHEDULED.

UNDERSIDE OF STRUCTURE.

METAL RUNNER (20 GA. MIN.)ANCHOR

@ 24" O.C. MAX.

METAL DEFLECTION TRACK WITH 3"

FLANGES.

PLAN

3/

4" M

IN

CEILING

BASE

HEAD

METAL RUNNER (20 GAUGE MIN) ANCHOR @

24" O.C. MAX.

FILL IN FLUTES WITH FIRE SAFING. APPLY

SEALANT EACH SIDE.

UNDERSIDE OF STRUCTURE

5/8" GYP. BD. EACH SIDE, FINISH AS

SCHEDULED

CEILING AS SCHEDULED

BASE EACH SIDE AS SCHEDULED

METAL RUNNER (20 GAUGE MIN)

ANCHOR @ 24" O.C. MAX.

HEAD

CEILING

BASE

PLAN

3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK AND EQUIPMENT

3 5/8" METAL STUDS (20 GA. MIN.)

AT 16" O.C. MAX.

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK, AND EQUIPMENT

3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK, AND EQUIPMENT

3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.

3. FOR FIRE RATED PARTITIONS, PROVIDE UL LISTED HEAD OF WALL

CLOSURE TO MATCH RATING OF WALL OR GREATER.

2. FOR ALL PARTITIONS PARALLEL TO DECK FLUTES, CLOSE FLUTES

ABOVE WALLS WITH CONTINUOUS GALVANIZED 18 GAGE SHEET

METAL CLOSURE.

4. FOR SOUND ATTENUATION & MOISTURE CONTROL PARTITIONS,

PROVIDE CONTINUOUS ACOUSTICAL SEALANT. FOR ALL OTHER

PARTITIONS, PROVIDE TYPE 4 SEALANT: (1 PART ACRYLIC LATEX

TYPE, ASTM C 834).

1. FOR SOUND ATTENUATION PARTITIONS, PACK FLUTES FULL WITH

SOUND ATTENUATION INSULATION.

FOR RATED PARTITIONS, PACK FLUTES FULL WITH FIRE SAFING

INSULATION.

FOR THERMAL PARTITIONS, PACK FLUTES FULL WITH SEMI-RIGID

INSULATION, TYPE 1.

FOR ALL OTHER CONDITIONS, CLOSE DECK OFF WITH NEOPRENE &

SEAL EDGES

PARTITION PERPENDICULAR

TO METAL DECK FLUTES

PARTITION PARALLEL TO

METAL DECK FLUTES

3-1/8"

N O

N -R

AT

ED

W

AL

L R

AT

ED

W

AL

L

CONTROL JOINT.

DISTANCE

BETWEEN JOINTS

30'-0" O.C. MAX

GYPSUM WALLBOARD

ON METAL STUDS-

REFER TO PLANS FOR

PARTITION TYPES.

BACKER ROD &

ACOUSTICAL SEALANT @

WALLS W/ ACOUSTICAL

INSULATION ONLY.

JOINT COMPOUND-

FEATHER OUT MIN. 12"

FROM CONTROL JOINT.

(LEVEL 4 FINISH)

SKIM ENTIRE SURFACE

(LEVEL 5 FINISH)

5/8"

1/2"

MAX.

C LL C

JOINT COMPOUND-

FEATHER OUT MIN. 12"

FROM CONTROL JOINT.

CONTROL JOINT.

GYPSUM WALLBOARD

ON METAL STUDS-

REFER TO PLANS FOR

PARTITION TYPES.

ACOUSTIC SEALANT EACH SIDE

PROVIDE INSULATION BATTS CONTINUOUS TO

UNDERSIDE OF STRUCTURE ABOVE

HEAD

CEILING

I N T E R I O R R O O M S I D E

S H A F T

UNDERSIDE OF STRUCTURE

METAL RUNNER (20 GAUGE MIN) ANCHOR @ 24"

O.C. MAX.

PROVIDE FIRE-RATED HEAD OF WALL DETAIL AT

INTERSECTION WITH STRUCTURE ABOVE

CEILING AS SCHEDULED

PROVIDE FIRE-RATED BOTTOM OF WALL DETAIL AT

WALL INTERSECTION WITH STRUCTURE.

BASE AS SCHEDULED

(1) LAYER 1" TYPE "X" GYPSUM SHAFT SIDE

METAL RUNNER (20 GAUGE MIN) ANCHOR @

24" O.C. MAX.BASE

PLAN

(2) LAYERS 5/8" TYPE 'X' GYP. BD. ONE SIDE

2-1/2" C-H STUDS, PROVIDE GAUGE AS REQUIRED

FOR CONDITIONS WHERE INSTALLED

1-1/2" BATT INSULATION

APPLY SAFING AT TOP OF GYPSUM BOARD

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK AND EQUIPMENT

DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK AND EQUIPMENT

UNDERSIDE OF STRUCTURE.

METAL RUNNER (20 GA. MIN.)ANCHOR

@ 24" O.C. MAX.

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK AND EQUIPMENT

SHEET METAL BLOCKING (12 GA. MIN) SIZED 2"

LARGER EACH DIRECTION THAN DIM. OF WALL

HUNG EQUIPMENT

FILL IN FLUTES WITH FIRE SAFING. APPLY SMOKE

SEALANT. (PER UL HEAD OF WALL REQUIREMENTS.)

(2) LAYERS 5/8" TYPE "X" GYPSUM SHAFT SIDE

5/8" GYP. BD. EACH SIDE. FINISH AS SCHEDULED

UNDERSIDE OF STRUCTURE

METAL RUNNER (20 GA. MIN.)

CEILING AS SCHEDULED

CEILING/HEAD

BASE

BASE EACH SIDE AS SCHEDULED

METAL RUNNER (20 GAUGE MIN) ANCHOR

@ 24" O.C. MAX.

BRACE TO STRUCTURE ABOVE @ 4' O.C.

STAGGER BRACES SIDE TO SIDE.

2'-0"

TYP.

SOUND ATTENUATION BATTS

4" M

IN

2'-0"

TYP.

PLAN

3 5/8" METAL STUDS (20 GA. MIN.) AT 16" O.C. MAX.

20 GA. DOUBLE STUDS @ ALL WALL HUNG

MILLWORK, CASE WORK, AND EQUIPMENT

3 1/2" SOUND ATTENUATION BATTS

SOUND ATTENUATION BLANKET

WHERE SCHEDULED

SOUND ATTENUATION BLANKET

WHERE SCHEDULED

CONTINUOUS SEALANT EACH SIDE

FILL IN FLUTES WITH FIRE SAFING; APPLY SMOKE

SEALANT. (PER UL HEAD OF WALL REQUIREMENT)

NOTE: PROVIDE DEFLECTION CHANNEL WHERE REQUIRED.

NOTE: PROVIDE DEFLECTION CHANNEL WHERE REQUIRED.

2 1/2" METAL STUDS (20 GA. MIN) AT

16" OC MAX.

FILL IN FLUTES WITH FIRE SAFING. APPLY SMOKE

SEALANT. (PER UL HEAD OF WALL REQUIREMENTS.)GYPSUM CUT WIDTH OF

STUD FOR SNUG FIT.

PLAN

CEILING

EXISTING WALL

HEAD

METAL WALL PANEL

CEILING AS SCHEDULED

METAL WALL PANEL

UNDERSIDE OF STRUCTURE.

METAL RUNNER (20 GAUGE MIN)

ANCHOR @ 24" O.C. MAX.

CONTINUOUS SEALANT

5/8" GYPSUM BOARD

2 1/2" METAL STUDS

BASE

ACCESS FLOOR SYSTEM

BASE AS SCHEDULED.

ANCHOR PER MANUF.

RECOMMENDATION

METAL WALL PANEL

UNDERSIDE OF DECK CONDITIONS

PLAN DETAIL - SOUND PARTITION

CONTROL JOINT DETAIL

A

N.T.S.

N.T.S.

Y

Y

X

PARTITION BETWEEN TAGS

WILL BE CONSTRUCTED AS

SHOWN ON PARTITION TYPE

SHEETS RESPECTIVELY TO

TYPE INDICATED.

PARTITION TYPE TAG

INDICATES PARTITION TYPE

AND DIRECTION UNTIL THE

END OF THE PARTITION OR A

NEW TAG OCCURS.

PARTITION

Z

X

N.T.S. APARTITION TYPE

NON-RATED

B

C

D

N.T.S. BPARTITION TYPE

NON RATED W/ SOUND REDUCTION

N.T.S. CPARTITION TYPE

NON RATED (ACOUSTIC DAMPING)

N.T.S. DPARTITION TYPE

NON-RATED

N.T.S. EPARTITION TYPE

PARTITION TYPE 1-HR RATED (UL #U465)

E

N.T.S. FPARTITION TYPE

PARTITION TYPE 2-HR RATED (UL #U411)

F

G

N.T.S. GPARTITION TYPE

51 STC RATED - RAL-TL-90-166 - SA 860620 - UL465

H

N.T.S. HPARTITION TYPE

N.T.S. JPARTITION TYPE

N.T.S. KPARTITION TYPE

J

K

N.T.S. LPARTITION TYPE

1-HOUR FIRE RATED SHAFT WALL (PER UL # U469)

L

N.T.S. MPARTITION TYPE

2-HOUR FIRE RATED SHAFT WALL (PER UL # U428)

M

GENERAL NOTES

PLAN DETAIL - FIRE RATED PARTITION

CONTROL JOINT DETAIL

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

N.T.S. NPARTITION TYPE

SHEET ISSUE

TYPICAL

PARTITION

TYPES

01G.100

N.T.S.

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

SHEET ISSUE

UL DETAILS

01G.200

ENTRANCE

EMERGENCY

OPERATIONS CENTER

CORR.

CORR.

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

BREAK

ROOM

IT / CONTROL

ROOM

CONFERENCE

ROOM

151A

COPY

CENTER

151C

STORAGE

151B

ADMIN.

OPERATIONS

151D

LOBBY

RECEPTION

BREAKOUT A

143A

BREAKOUT B

143B

'-1

0"

CORRIDOR

STORAGE

151E

VESTIBULE

128A

'-4

VEST.

141A

SHEET ISSUE

LIFE

SAFETY PLAN

01LS.10101PARTIAL FLOOR PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

MOBILE

SPEAKER

PODIUM

MOBILE

SEATING

TABLES FOR

RAMP

RAMP

EX

IT

S

EP

AR

AT

IO

N

T O

B E

'-1

" M

IN

1/

O

F R

O O

M D

IA

G

O N

AL

'-4

" F T.

EXIT LIGHT (ARROW INDICATES TRAVEL DIRECTIONAL ARROW), SEE

ELECTRICAL PLAN (EX = EXISTINGTO REMAIN WHERE SHOWN ON PLANS)

EMERGENCY LIGHT / NIGHT LIGHT FIXTURES

EGRESS CAPACITY OF

EXIT COMPONENT (IN

PERSONS)

EX = EXISTING

EXISTING FIRE EXTINGUISHER AND/OR CABINET

(EX = EXISTING TO REMAIN WHERE SHOWN ON PLAN)

FE

DOOR

EXIT COMPONENT

MEANS OF EGRESS DOORS SHALL PROVIDE A

MINIMUM WIDTH OF 32 INCHES (PER DOOR) WITH

THE DOOR OPEN 90 DEGREES, MEASURED

BETWEEN THE FACE OF THE DOOR AND THE

OPPOSITE STOP AS REQUIRED BY 11-4.13.5

FLORIDA ACCESSIBILITY CODE FOR BUILDING

CONSTRUCTION, FBC 2020, AND 7.2.1.2.2, NFPA 101.

EX

EX

LIFE SAFETY LEGEND

COMMON PATH OF EGRESS TRAVEL (W/ INDICATED DISTANCE)

00'

3'-6"* INDICATES WIDTH OF EGRESS PATH AT EACH INTERNAL SEGMENT

(BASED ON CURRENT FURNISHINGS LAYOUT)

RELOCATED EMERGENCY LIGHT LOCATION SHOWN ON LIFE

SAFETY & REFLECTED CEILING PLANS; INDICATED W/ TAG 'ER'

** REFER TO NOTE AT BUILDING CODE ANALYSIS REGARDING EXISTING EGRESS

PATH OF TRAVEL TO REMAIN UNCHANGED & THEREFORE NOT DELINEATED IN

THESE PLANS.

MAXIMUM PATH OF EGRESS TRAVEL (W/ INDICATED DISTANCE)

00'

ROOM AREA

OCC. LOAD FACTOR

OCCUPANT LOAD

REQUIRED EXIT WIDTH

# IN

BUSINESS OCCUPANCY

100 SF/ PERS

SMALL ASSEMBLY -

UNCONCENTRATED

15 SF/ PERS

OCCUPANT LOAD

BASED ON TABLE 1004.1.2 & NFPA 7.3.1.2

FUNCTION OF SPACE AREA PER

OCCUPANT

TOTAL OCCUPANTS

EGRESS WIDTH

TABLE 1005.1 & NFPA 101-7.3.3.1

ROOM OCC.

TYPE

TOTAL

OCCUPANCY

REQUIRED EGRESS WIDTH

STAIRWAYS (INCHES) OTHER EGRESS

COMPONENTS (INCHES)

PROVIDED EGRESS WIDTH

STAIRWAYS (INCHES) EGRESS DOORWAYS

(INCHES)

EGRESS ACCESS TRAVEL DISTANCE

TABLE 1016.1 & NFPA 101-38.2.6.2

FLOOR OCCUPANCY

TYPE

ALLOWABLE EXIT ACCESS

TRAVEL DISTANCE (IN FEET)

ACTUAL MAXIMUM EXIT ACCESS

TRAVEL DISTANCE (IN FEET)

COMMON PATH OF EGRESS TRAVEL

TABLE 1014.3 & NFPA 101-39.2.5.3.3

FLOOR OCCUPANCY

TYPE

ALLOWABLE COMMON PATH OF

TRAVEL DISTANCE (IN FEET)

ACTUAL MAXIMUM COMMON PATH OF

TRAVEL DISTANCE (IN FEET)

DEAD END CORRIDOR REQUIREMENTS

SECTION 1018.4 & NFPA 101-39.2.5.2

FLOOR OCCUPANCY

TYPE

ALLOWABLE DEAD END CORRIDOR

DISTANCE (IN FEET)

ACTUAL MAXIMUM DEAD END

CORRIDOR DISTANCE (IN FEET)

100 7 OCCUPANTSGROUP-B

BUSINESS

254 0.2" (254) = 51 64N/A N/AALL BUSINESS

1 200BUSINESS 122

1 100BUSINESS 46

1 20 N/ABUSINESS

15 246 OCCUPANTSGROUP-B

SMALL ASSEMBLY

300 1 OCCUPANTSSTORAGE

254 OCCUPANTS

RENOVATED AREA

TOTAL

EXIT WIDTH

EXIT CAPACITY

2,352

32 IN

1 @ 32"

2"

4 IN

4 IN

4 IN

0.4 IN

1. EXISTING BUILDING IS TYPE IV, FULLY SPRINKLERED

NO CHANGES TO USE OR OCCUPANCY

2. LEVEL 2 ALTERATION

LIFE SAFETY NOTES

1.8 IN

1.8 IN

60'-2"

69'-2"

0.2 IN

0.8 IN

122 '

STORAGE OCCUPANCY

300 SF/ PERS

NO WORK

THIS AREA

FE

AED

EXISTING AUTOMATED EXTERNAL DEFIBRILLATOR AND/OR CABINET

(EX = EXISTING TO REMAIN WHERE SHOWN ON PLAN)EXAED

0.2 IN

3.0 IN

RELOCATED

EXISTING

EXTERNAL

DEFIBRILLATOR

FE

EXISTING

ONE-HOUR

RATED WALL

NEW ONE-HOUR

RATED WALL

EXISTING ONE HOUR RATED WALL

NEW ONE HOUR RATED WALL

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

6FT

OPERATIONS CENTER

MESSAGE

CENTER

GIS

CENTER

145B

PIO

CENTER

145A

CORR.

HAM

RADIO

CORR.

LOBBY

BREAK

ROOM

IT / CONTROL

ROOM

CONFERENCE

ROOM

151A

ADMIN.

OPERATIONS

151D

STORAGE

151C

COPY

CENTER

151B

CORR.

BREAKOUT A

143A

BREAKOUT B

143B

RECP.

VESTIBULE

128A

STORAGE

151E

VEST.

141A

GENERAL NOTES

SHEET ISSUE

OVERALL

FLOOR PLAN

01A.10001OVERALL FLOOR PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

NO WORK

THIS AREA

HATCH INDICATES

NOT IS SCOPE

A.101

AD.101

EAST

COVERED

ENTRY

NORTH

COVERED

ENTRY

WEST

COVERED

ENTRY

SOUTH

COVERED

ENTRY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/8"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

12FT

OPERATIONS CENTER

CORR.

CLOSET

151D

ENTRANCE

OPERATIONS

DESK

151C

EOC

CONTROL

151B

COPY

CENTER

151A

IT EQUIP.

ROOM

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

CLOSET

151E

VEST.

128A

CORRIDOR

3' -9

7 3/4"

5'-0" 5'-4 1/2"

GENERAL NOTES

SHEET ISSUE

PARTIAL

DEMOLITION

PLAN

01AD.10101PARTIAL DEMOLITION PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

D01 EXISTING WALL TO BE REMOVED

D02 EXISTING DOOR AND FRAME TO BE

REMOVED

D03 EXISTING MILLWORK TO BE REMOVED

D04 EXISTING PLAN TABLES TO BE REMOVED

D05 EXISTING RAISED FLOOR TO BE REMOVED

D06 EXISTING SYSTEMS FURNITURE TO BE

REMOVED

D07 EXISTING SERVERS TO BE REMOVED;

RETURN TO OWNER FOR DISPOSITION

D08 RETURN ALL CHAIRS TO OWNER

D09 RETURN ALL EXISTING TECH. TO OWNER

D10 REMOVE EXISTING FLOORING AND BASE;

PREP FOR NEW FLOORING AND BASE;

PATCH AND LEVEL

D11 REMOVE EXISTING RAMP AND ASSOCIATED

RAILING

D12 EXISTING AED TO BE REMOVED AND

RE-INSTALLED AS DIRECTED BY OWNER

D13 REMOVE EXISTING POWER POLE

D14 REMOVE EXISTING WHITE BOARD

D15 EXISTING COLUMN TO REMAIN

D16 REMOVE EXISTNG GLAZING AND FRAME

D17 PROTECT EXISTING DOORS, TYPICAL

D18 PROTECT ELEVATOR DOORS, FRAME, CAB,

AND CONTROLS

D19 EXISTING DISPLAY CASE TO BE RELOCATED

DEMOLITION FLOOR PLAN - KEY NOTESDXX

D04

D01

D02

D03

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

D05

D01

D06

D01

D01

D01

D02

AD.401

3D

2D

4D

1D

D07

TYP.

D01

D02

D02

D01

D05

TYP.

D11

D02

D08

TYP.

D11

D10

D10

D02

D02

D02

D10

AD.401

7D

6D

8D

5D

D12

D15

D14

D13

D08

TYP.

D04

TYP.

D03

D10

D16

D08

D04

D04

D08

D04

D08

D15

D16

D17

D10

D17

D10D17

D18

AD.402

3D

2D

4D

1D

D19

D08

D04

D06

D08

D08

D01

D08

D03

AD.402

6D

5D

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text s s s s s s s s s s s s s s s s s s s s s

EMERGENCY

OPERATIONS CENTER

CORR.

CLOSET

151D

ENTRANCE

OPERATIONS

DESK

151C

EOC

CONTROL

151B

COPY

CENTER

151A

IT EQUIP.

ROOM

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

CLOSET

151E

VEST.

128A

GENERAL NOTES

SHEET ISSUE

PARTIAL DEMO.

REFLECTED

CEILING PLAN

01AD.11101PARTIAL DEMO. REFLECTED CEILING PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

DEMOLITION REFLECTED CEILING PLAN -

KEY NOTESDXX

D01 REMOVE EXISTING CEILING TILE & GRID

D02 REMOVE EXISTING LIGHTING

D03 REMOVE EXITING MECHANICAL DIFFUSER

D04 REMOVE EXISTING TRACK LIGHTING

D05 REMOVE EXISTING CEILING MOUNTED

PROJECTOR; RETURN TO OWNER

D06 REMOVE EXISTING SPEAKER

D07 EMERGENCY LIGHTING TO REMAIN (TYP)

D04

D05

D01

D02 D03

D02

D03

D02

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

D01 D05

TYP.

TYP.

TYP.

D01

D02

D03

D05

D05

D06

D07

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

N.T.S. 3DROOM 151 INTERIOR ELEVATION - EAST

FOR REFERENCE ONLY

N.T.S. 2DROOM 151 INTERIOR ELEVATION - SOUTH

FOR REFERENCE ONLY

N.T.S. 1DROOM 151 INTERIOR ELEVATION - NORTH

FOR REFERENCE ONLY

N.T.S. 4DROOM 151 INTERIOR ELEVATION - WEST

FOR REFERENCE ONLY

N.T.S. 7DRECEPTION INTERIOR ELEVATION - EAST

FOR REFERENCE ONLY

N.T.S. 6DRECEPTION INTERIOR ELEVATION - SOUTH

FOR REFERENCE ONLY

N.T.S. 5DRECEPTION INTERIOR ELEVATION - NORTH

FOR REFERENCE ONLY

N.T.S. 8DRECEPTION INTERIOR ELEVATION - WEST

FOR REFERENCE ONLY

01 DEMO EXISTING WALL

02 DEMO EXISTING CEILING & PREP FOR NEW

03 DEMO EXISTING FLOORING & PREP FOR NEW

04 DEMO EXISTING MILLWORK

05 DEMO EXISTING DOOR & FRAME

06 DEMO EXISTING LIGHTING

07 REMOVE EXISTING PARTITION

08 REMOVE & STORE FOR RELOCATION

09 PREP SURFACE FOR NEW PAINT / FINISH

10 EXISTING RATED COLUMN ASSEMBLY

TO REMAIN

SOME NOTES MAY NOT APPLY ON ALL SHEETS

INTERIOR ELEVATION - DEMO NOTESXX

07 07

09 09

01 10

01 09

01 09

SHEET ISSUE

DEMO

ELEVATIONS

01AD.401

DOOR, SEE SCHEDULE

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

N.T.S. 1DELEVATOR LOBBY - NORTH

FOR REFERENCE ONLY

01 DEMO EXISTING WALL

02 DEMO EXISTING CEILING & PREP FOR NEW

03 DEMO EXISTING FLOORING & PREP FOR NEW

04 DEMO EXISTING MILLWORK

05 DEMO EXISTING DOOR & FRAME

06 DEMO EXISTING LIGHTING

07 REMOVE EXISTING PARTITION

08 REMOVE & STORE FOR RELOCATION

09 PREP SURFACE FOR NEW PAINT / FINISH

10 EXISTING RATED COLUMN ASSEMBLY

TO REMAIN

SOME NOTES MAY NOT APPLY ON ALL SHEETS

INTERIOR ELEVATION - DEMO NOTESXX

N.T.S. 2DELEVATOR LOBBY - EAST

FOR REFERENCE ONLY

N.T.S. 3DELEVATOR LOBBY - SOUTH

FOR REFERENCE ONLY

N.T.S. 4DELEVATOR LOBBY - WEST

FOR REFERENCE ONLY

N.T.S. 5DBREAK ROOM - WEST

FOR REFERENCE ONLY

N.T.S. 6DBREAK ROOM - EAST

FOR REFERENCE ONLY

SHEET ISSUE

DEMO

ELEVATIONS

01AD.402

OPERATIONS CENTER

CORR.

CORR.

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

BREAK

ROOM

IT / CONTROL

ROOM

CONFERENCE

ROOM

151A

COPY

CENTER

151C

STORAGE

151B

ADMIN.

OPERATIONS

151D

LOBBY

RECEPTION

BREAKOUT A

143A

BREAKOUT B

143B

128A

0A

1A

143A 143B

CORRIDOR

STORAGE

151E

VESTIBULE

128A

VEST.

141A

2' -8

13'-10" 7'-7" 5'-1 3/4" 13'-0" 11'-6" 5'-0" 10'-10 1/4"9'-10 1/4"

1A

1C

1B

1D

3' -6

'-7

/2

'-3

/2

2' -0

3'

-5

5'-0"6'-0 1/2"

9' -5

/4

9'-7" 9'-0 1/2" 9'-8"3'-8 1/4" 3'-4" 3'-8 1/2" 3'-8 1/2" 5'-4 1/4"

3' -5

/4

'-3

/4

'-1

3/

4" 3'

-4

2'-3 1/2" 5'-10 1/4"

4' -7

/4

GENERAL NOTES

SHEET ISSUE

PARTIAL

FLOOR PLAN

01A.10101PARTIAL FLOOR PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

01 NEW PARTITION

02 NEW DOOR AND FRAME

03 NEW GLASS SURFACE MEDIA WALL SYSTEM

ON ALUMINUM GRID

04 NEW MILLWORK

05 NEW MOBILE FURNITURE

06 NEW RAISED FLOOR

07 NEW BULLET-RESISTANT GLASS ENCLOSURE

08 NEW SLIDING DOOR

09 NEW 85" TV

10 NEW 45" TV ABOVE

11 NEW MEDIA WALL SYSTEM

12 NEW SERVER RACK. COORDINATE WITH

IT DRAWINGS

13 NEW ELECTRICAL PANEL

14 RELOCATED DISPLAY CASE

15 IT RACK CLEARANCE

16 NEW ADJUSTABLE SHELVING

17 NEW MEDIA WALL SYSTEM IN FRONT OF

EXISTING PARTITION

18 LOGO

19 COPIER

20 INFILL OPENING. SHALL BE TRUE AND FLUSH

WITH EXISTING WALL

21 STUB WALL. COORDINATE WITH MEDIA WALL

SYSTEM TO MATCH THICKNESS AND HIDE

SEAM.

22 RE-USE EXISTING FLOOR PENETRATIONS

ABOVE FOR WIRING TO 2nd FLOOR -

COORD. WITH TECHNOLOGY DRWGS. AND

OWNER

FLOOR PLAN - KEY NOTESXX

MOBILE

SPEAKER

PODIUM

RAMP

RAMP

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

TYP.

A.401

ALIGN

TYP.

TYP.

04 07

TYP.

11 11

D

D

ED

A.402

A.402

A.403

A.401

A.403

AL

IG

N

A.340

A.340

A.340

D

E

A/ V

R

AC

KS

N

ET

W

O R

K R

AC

KS

A.351

A.351

A.351

A.602

ALIGN

D

D

D

A.603

09 09

N

D

NEW GYPSUM BOARD PARTITION

NEW MEDIA WALL

EXISTING TO REMAIN

WALL LEGEND

A.603

D

A.40405

A.603

N

A.340

A.340

A.603

AL

IG

N

ALIGN

ALIGN

ALIGN

D D

A.40408

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OPERATIONS CENTER

CORR.

CORR.

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

BREAK

ROOM

IT / CONTROL

ROOM

CONFERENCE

ROOM

151A

COPY

CENTER

151C

STORAGE

151B

ADMIN.

OPERATIONS

151D

LOBBY

101RECEPTION

BREAKOUT A

143A

BREAKOUT B

143B

CORRIDOR

STORAGE

151E

VESTIBULE

128A

VEST.

141A

6'-0" 5'-8"6'-0"13'-1 1/2"5'-8" 6'-0" 6'-0"

5'-8"6'-0"6'-0"13'-1 1/2"6'-0"

5'-8"6'-0"6'-0"13'-1 1/2"6'-0"11'-7 3/4"

5'-8"6'-0"6'-0"6'-0"6'-0"5'-7 3/4"

8'-9"2'-11"

6'-6 1/2"6'-6 1/2" 6'-3 1/2"6'-3 1/2"

'-5

'-5

/4

'-5

'-5

/4

8' -6

/2

'-0

'-0

'-0

6' -9

/4

6'-1 1/2" 7'-0"

4' -9

/2

'-8

GENERAL NOTES

SHEET ISSUE

ACCESS

FLOOR PLAN

01A.10201PARTIAL FLOOR PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

RAMP

RAMP

01 2' x 2' CARPET TILE ON ACCESS FLOOR

02 FLOOR BOX POWER AND DATA OUTLET

ACCESS FLOOR - KEY NOTESXX

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

TYP.

02 02

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text s s s s s s s s s s s s s s s s s s s s

3' FIXTURE

2' FIXTURE

2' FIXTURE

2' F

IX

TU

R E

3' F

IX

TU

R E

3' F

IX

TU

R E

2' F

IX

TU

R E

3' F

IX

TU

R E

2' F

IX

TU

R E

2' F

IX

TU

R E

2' F

IX

TU

R E

2' FIXTURE

s s s s s s s s s s s s s s s s s s

EMERGENCY

OPERATIONS CENTER

CORR.

CORR.

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

BREAK

ROOM

IT / CONTROL

ROOM

CONFERENCE

ROOM

151A

COPY

CENTER

151C

STORAGE

151B

ADMIN.

OPERATIONS

151D

LOBBY

101RECEPTION

BREAKOUT A

143A

BREAKOUT B

143B

CORRIDOR

STORAGE

151E

VESTIBULE

128A

VEST.

141A

GENERAL NOTES

SHEET ISSUE

PARTIAL

REFLECTED

CEILING PLAN

01A.11101PARTIAL REFLECTED CEILING PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

REFLECTED CEILING PLAN - KEY NOTESXX

01 ACT CEILING

02 WOOD GRILLE CEILING

03 LINEAR METAL CEILING

04 GYPSUM BOARD CEILING

05 LIGHT FIXTURE

06 MECHANICAL DIFFUSER

07 LINEAR LED LIGHT FIXTURE 4'-0" IN

LENGTH UNLESS OTHERWISE NOTED

08 SLOT DIFFUSER

09 PTZ CAMERA

10 SPEAKER NEW OR EXISTING

11 PENDANT LIGHT FIXTURE

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

TYP.

TYP.

02 07

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

A.602

A.602

FIN. CLG.

8'-8"

FIN. CLG.

9'-0"

FIN. CLG.

9'-0"

(MATCH

EXISTING)

FIN. CLG.

+8'-9"

A.602

A.602

A.602

NEW GYPSUM BOARD CEILING

NEW ACT CEILING

NEW WOOD GRILLE CEILING

NEW LINEAR METAL CEILING

CEILING LEGEND

A.341

FIN. CLG.

+8'-9"

FIN. CLG.

+8'-9"

FIN. CLG.

+9'-0"

(MATCH

EXISTING)

FIN. CLG.

9'-0"

(MATCH

EXISTING)

FIN. CLG.

+8'-9"

A.602

A.602

TYP.

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text s s s s s s s s s s s s s s s s

3' FIXTURE

2' FIXTURE

2' FIXTURE

2' F

IX

TU

R E

3' F

IX

TU

R E

3' F

IX

TU

R E

2' F

IX

TU

R E

3' F

IX

TU

R E

2' F

IX

TU

R E

2' F

IX

TU

R E

2' F

IX

TU

R E

2' FIXTURE

2'-0" 2'-0" 2'-0" 2'-0" 2'-6 1/2" 2'-6 1/2" 2'-3 1/2" 2'-3 1/2"

2'-0" 2'-0" 2'-0" 2'-0"

2'-3" 11"1'-2" 3'-3" 2'-8" 1'-2"

2'-11" 4'-3" 5'-0" 4'-6" 4'-3" 4'-3" 4'-5" 3'-10" 5'-0" 2'-8" 4'-0"

9" 10" 8"

1'-2" 10"

2'-3" 1'-0"

1'-6"

1'-6"

1'-9"

1'-0"8"

6"

2'-0"

1'-1"

1'-10"

2'-3"

2'-8"

6"

3'-3"

1'-10

6"1'-9"

4' -7

5'-8" 12'-0" 12'-9" 11'-9 1/2" 6'-8"

4' -1

0"

'-0

'-0

'-6

6' -0

8'-0"

4' -3

/4

12"

6' -0

6'

-0

2'-5" 4'-10" s

1' -8

3'

-4

1' -8

1'

-8

1' -8

1'

-8

2'-7" 2'-7" 1'-1"

3'-9" 1'-5" 4'-0" 4'-0" 1'-7"

7'-1"

2' -3

3'-0"

4"

1' -5

1' -8

1' -8

1'-9"

6'-3"3'-3 1/2"9'-0"

1'-8 1/2"

2'-0" 2'-8 1/2"1'-8" 9 1/2" 2'-1" s s s s s s s s s s s s s s s s s

2' -3

/2

1' -1

1' -1

1" 2'

-1

1' -0

1'

-0

1' -7

6' -0

1' -7

1' -0

1'

-0 "4' -3

/4

5'

-0

5' -0

2'-7 1/4"

EMERGENCY

OPERATIONS CENTER

CORR.

CORR.

HAM

RADIO

MESSAGE

CENTER

PIO

CENTER

145A

GIS

CENTER

145B

BREAK

ROOM

IT / CONTROL

ROOM

144CONFERENCE

ROOM

151A

COPY

CENTER

151C

STORAGE

151B

ADMIN.

OPERATIONS

151D

LOBBY

RECEPTION

BREAKOUT A

143A

BREAKOUT B

143B

CORRIDOR

STORAGE

151E

VESTIBULE

128A

VEST.

141A

1' -7

9'

-1

2' -0

"11 '-3

2' -0

9'

-0

/4

1'-7"7'-7"

GENERAL NOTES

SHEET ISSUE

REFLECTED

CEILING

DIMENSION

PLAN

01A.11201REFLECTED CEILING DIMENSION PLAN

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

REFLECTED CEILING PLAN - KEY NOTESXX

01 ACT CEILING

02 WOOD GRILLE CEILING

03 LINEAR METAL CEILING

04 GYPSUM BOARD CEILING

05 LIGHT FIXTURE

06 MECHANICAL DIFFUSER

07 LINEAR LED LIGHT FIXTURE 4'-0" IN

LENGTH UNLESS OTHERWISE NOTED

08 SLOT DIFFUSER

09 PTZ CAMERA

10 SPEAKER NEW OR EXISTING

11 PENDANT LIGHT FIXTURE

NO WORK

THIS AREA

NO WORK

THIS AREA

NO WORK

THIS AREA

W O

O D

G R

IL

LE

C

EI

LI

N

G

WOOD GRILLE CEILING

AutoCAD SHX Text

SCALE

AutoCAD SHX Text 1/4"= 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

Floor

3"3"3"

3 3/4"

SHEET ISSUE

FLOOR AND

WALL SYSTEM

DETAILS

01A.340

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

01ACCESS FLOOR DETAILS

MEDIA WALL

SYSTEM -

BASIS OF DESIGN

"DIRTT" SYSTEM

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

ACCESS FLOOR

SYSTEM -

BASIS OF DESIGN

"DIRTT" FLOOR

CEILING AS

SCHEDULED

0 1 FT6 IN 1 1/2 FT1"= 1'-0"

SCALE 02MEDIA WALL SECTION0 1 FT6 IN 1 1/2 FT1"= 1'-0"

SCALE 03MEDIA WALL SECTION0 1 FT6 IN 1 1/2 FT1"= 1'-0"

SCALE 04GLASS WALL SECTION

5/8" GYPSUM BOARD ON EACH

SIDE ON 3 5/8" METAL STUDS

AT 16" O.C. ( 25 GA. MIN. )

CONTINUOUS SEALANT

EACH SIDE

METAL RUNNER ( 20 GA.

MIN. ) ANCHOR AT 24"

O.C. MAX.

UNDERSIDE OF

STRUCTURE

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

CEILING AS

SCHEDULED

5/8" GYPSUM BOARD ON

3 5/8" METAL STUDS AT

16" O.C. ( 25 GA. MIN. )

CONTINUOUS SEALANT

EACH SIDE

METAL RUNNER ( 20 GA.

MIN. ) ANCHOR AT 24"

O.C. MAX.

UNDERSIDE OF

STRUCTURE

EXISTING WALL

TO REMAIN

GLASS WALL

SYSTEM - WITH

SWITCHABLE

PRIVACY GLASS

CEILING AS

SCHEDULED

CONTINUOUS SEALANT

EACH SIDE

METAL RUNNER ( 20 GA.

MIN. ) ANCHOR AT 24"

O.C. MAX.

UNDERSIDE OF

STRUCTURE

SOUND ATTENUATION

BLANKETS

SOUND ATTENUATION

BLANKETS

5/8" GYPSUM BOARD ON EACH

SIDE ON 3 5/8" METAL STUDS

AT 16" O.C. ( 25 GA. MIN. )

MEDIA WALL

SYSTEM -

BASIS OF DESIGN

"DIRTT" SYSTEM

ACCESS FLOOR

SYSTEM -

BASIS OF DESIGN

"DIRTT" FLOOR

ACCESS FLOOR

SYSTEM -

BASIS OF DESIGN

"DIRTT" FLOOR

WALL SYSTEM

RAISED FLOOR

SYSTEM

POWER AND

DATA FEED

0 6 IN33"= 1'-0"

SCALE 05BASE DETAIL

0 6 IN33"= 1'-0"

SCALE 06WALL DETAIL

A.340

A.340

WALL SYSTEM

0 6 IN33"= 1'-0"

SCALE 07WALL DETAIL

0 6 IN33"= 1'-0"

SCALE 08HEAD DETAIL

A.340

EXISTING WALL

TO REMAIN

A.340

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

WALL SYSTEM

PANEL JOINT -

SEE INTERIOR

ELEVATIONS FOR

LOCATIONS

A.341

A.341

WALL SYSTEM

PANEL JOINT

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

CEILING AS

SCHEDULED

CEILING AS

SCHEDULED

EXISTING WALL TO

REMAIN

EXISTING WALL TO

REMAIN

5/8" GYPSUM BOARD ON

3 5/8" METAL STUDS AT

16" O.C. ( 25 GA. MIN. )

FIN CLG

+8'-9"

( MATCH

EXISTING )

FIN FLOOR

0'-0"

( MATCH

EXISTING )

FIN FLOOR

0'-0"

( MATCH

EXISTING )

FIN CLG

+8'-9"

( MATCH

EXISTING )

3"

SHEET ISSUE

FLOOR AND

WALL SYSTEM

DETAILS

01A.341

839 N. MAGNOLIA AVE.

ORLANDO, FL 32803

# AR93580

E

R

ES

C U

E

- E

O C

O R

AN

G

E C

O U

N

TY

G O

VE

R

N M

EN

T

IN

TE

R

IO

R A

LT

ER

AT

IO

N S

A M

O R

Y C

O U

R T

W

IN

TE

R

P

AR

K, F

LO

R

ID

A

PROJECT #:

DATE: 07.07.2021

190608

ERIC OSKAR KLEINSTEUBER

FLORIDA LICENSE # AR93580

RELEASE

BID AND PERMIT

NO. DATE

01 07.07.2021

0 6 IN33"= 1'-0"

SCALE 01BASE DETAIL GENERAL NOTES

0 6 IN33"= 1'-0"

SCALE 02HEAD DETAIL

FLOOR TILE

EXISTING CONCRETE

SLAB TO REMAIN

CEILING AS

SCHEDULED

GLASS WALL

SYSTEM - WITH

SWITCHABLE

PRIVACY GLASS

GLASS WALL

SYSTEM - WITH

SWITCHABLE

PRIVACY GLASS

STEEL SUPPORT

0 6 IN 1 FT

SCALE

1-1/2"= 1'-0" 06SECTION DETAIL

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

TV MONITOR

WHERE SCHEDULED -

SEE FLOOR PLAN AND

INTERIOR ELEVATIONS

ACCESS FLOOR

SYSTEM -

BASIS OF DESIGN

"DIRTT" FLOOR

0 6 IN 1 FT

SCALE

1-1/2"= 1'-0" 05PLAN DETAIL

CEILING AS

SCHEDULED

WALL PANEL

SYSTEM

A. ALL ROOM NUMBERS ARE FOR CONSTRUCTION

PURPOSES ONLY.

B. USE ONLY WRITTEN DIMENSIONS. DO NOT

SCALE DRAWINGS.

C. THE CONTRACTOR SHALL VERIFY ALL

CONDITIONS & DIMENSIONS ON-SITE PRIOR TO

COMMENCING WORK; ALL INQUIRIES & NOTED

DISCREPANCIES SHOULD BE DIRECTED IN

WRITING TO THE ARCHITECT PRIOR TO

PROCEEDING WITH THE WORK/AREA IN

QUESTION.

D. ALL DIMENSIONS ARE TO FINISH FACE OF

SURFACE INDICATED UNLESS OTHERWISE

NOTED (UON).

E. PROVIDE ALL WARNING AND EGRESS SIGNAGE

IN COMPLIANCE WITH FLORIDA BUILDING CODE

DURING AND AFTER CONSTRUCTION.

F. SEE LIFE SAFETY PLAN FOR EXIT LIGHTS AND

FIRE EXTINGUISHER CABINETS.

G. ALL MILLWORK TO BE FIELD MEASURED /

VERIFIED BEFORE FABRICATING.

H. CONTRACTOR TO REPAIR ALL WALLS

AFFECTED BY DEMOLITION & EQUIPMENT

REMOVAL TO MATCH THE EXISTING ADJACENT

WALL SURFACES.

I. REMOVE ALL MONITORS, COMPUTERS,

PROJECTORS AND EQUIPMENT. RETURN TO

OWNER.

GENERAL NOTES

FIN CLG

+8'-9"

( MATCH

EXISTING )

MEDIA WALL

SYSTEM

EXISTING WALL

TO REMAIN

DOUBLE PIVOT

DOORS

5/8" GYPSUM BOARD ON EACH

SIDE ON 3 5/8" METAL STUDS

AT 16" O.C. ( 25 GA. MIN. )

SOUND ATTENUATION

BLANKETS

FIN FLOOR

0'-0"

( MATCH

EXISTING )

0 6 IN 1 FT

SCALE

1-1/2"= 1'-0" 07SECTION DETAIL

TV MONITOR