This document package includes construction drawings and specifications for the rehabilitation of windows, sills, and trim at the First Bank of the United States building within Independence National Historical Park. The project involves restoring all exterior wood windows through treatments such as replacing rotten wood, rebuilding solid wood sills, reglazing sashes, and refurbishing hardware. Interior storm windows will also be cleaned and reinstalled with new matching trim. Temporary enclosures and removable sashes are specified to facilitate HVAC equipment access. The solicitation is available through the National Park Service Northeast Region for qualified firms to rehabilitate the historic windows per the Secretary of the Interior's Standards.

View the file

Other files

File Type Posted
Sol_140P4220R0019_Amd_0002.pdf PDF
Rehabilitate First Bank Windows_0002.pptx PPTX presentation
Hazardous Materials Survey Report First National Bank_0001.pdf PDF
First Bank Windows Questions and Answers_0001.pdf PDF
Sol_140P4220R0019_Amd_0001.pdf PDF
PROJECT(CONSTRUCTION) - SPECIFICATIONS - 03-05-20.pdf PDF
References Worksheet.doc DOC document
Form B.docx DOCX document
Bid Guarantee SF24-16d.pdf PDF
Wage Determination PA20200003.pdf PDF
PAYMENT BOND SF25A-16d.pdf PDF
Sol_140P4220R0019.pdf PDF
PERFORMANCE BOND SF25-16d1 (1).pdf PDF
Form A.docx DOCX document
Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FAIRMOUNT AVE.

N D

S T

B R O A D

S T

T H

S T

T H

S T

R D

S T

T H

S T

WALNUT ST.

SPRING GARDEN ST.

DIAMOND

LEHIGH

ALLEGHENY AVE.

G E R M A N T O W N

A V E

. WYOMING AVE.

H E N R Y

A V E

W

IS

S A H

IC

K O N

A V E

PINE ST.

SOUTH ST.

CHESTNUT

ST.

RACE ST.

AVE.

ST.

CECIL

MOORE

AVE.

B E L M O N T

A V E

T H

S T

R

ID

G E

A V E

ERIE AVE.

R

IS

IN

G

S U N A V E

HAVERFORD

AVE.

ERIE AVE.

V.C.

HQ.

INDEPENDENCE

NATIONAL

HISTORICAL

PARK

PHILADELPHIA

KOSCIUSZKO

MEMORIAL

EDGAR ALLAN

POE N.H.S.

DESHLER-MORRIS

HOUSE

∅0.0879

WALNUT STREET

CHESTNUT STREET

MARKET STREET

ARCH STREET

RACE STREET

VINE STREET

SPRUCE STREET

F R O N T

S T R E E T

S E C O N D

S T R E E T

T H

IR

D

S T R E E T

F O U R T H

S T R E E T

F

IF

T H

S T R E E T

S

IX

T H

S T R E E T

S E V E N T H

S T R E E T

BENJAMIN FRANKLIN BRIDGE

DOCK

LOCUST STREET

NEW STREET

PARKING

GARAGE

D O C K

S T R E E T

ADMINISTRATION

OFFICES

WASHINGTON

SQUARE

WALNUT STREET

T H

IR

D

S T R E E T

S E C O N D

S T R E E T

MARKET STREET

ARCH STREET

S T

MAINTENANCE

FACILITY

TO

THADDEUS KOSCIUSZKO

NATIONAL MEMORIAL

INDEPENDENCE

HALL

LIBERTY

BELL

PAVILLION

TO

EDGAR ALLAN

POE NHS

CAMDEN

DELAWARE

RIVER

SCHUYLKILL

RIVER

NEW

JERSEY

PENNSYLVANIA

UNESCO

HQ.

V.C.

LEGEND

INDEPENDENCE NATIONAL HISTORICAL PARK

SCALE OF MILES

01 1

SCALE OF FEET

SCALE OF METERS

WORLD HERITAGE SITE

PARK

HEADQUARTERS

STATE

LINE

VISITOR

CENTER

PARK

BOUNDARY

REHABILITATE WINDOWS, SILLS, AND TRIM AT FIRST BANK OF THE UNITED STATES

THIS PROJECT

FIRST

BANK

A/E FIRM - GWWO Mark Sheet REVISION Date Initial QUALITY DESIGN CERTIFICATION Prepared in Accordance with Design

Development (Title I)

OR

Variance from Design Development (Title I)

Approved by Superintendent on

OR

Construction Drawing Not Preceded by Design Development (Title I)

Drawing No.

Date

Project Manager Date

UNITED STATES

TITLE OF DRAWING

DEPARTMENT OF THE INTERIOR

LOCATION WITHIN PARK

NAME OF PARK

REGION COUNTY STATE

DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

CONSTRUCTION DOCUMENTS

NATIONAL PARK SERVICE

DENVER SERVICE CENTER

INDEPENDENCE NATIONAL HISTORICAL PARK

NORTHEAST PHILADELPHIA PENNSYLVANIA

153035

224447

1 13

BASIC DATA: BOUNDARY MAP 123/80,011 5/86; USGS TOPO

MAP 1971; PARK MINI FOLDER; COVER SHEET REVISED &

REDRAWN 1/94. UPDATED 10/98. SGS.

INDEX OF DRAWINGS

SHEET SUB SHEET TITLE OF SHEET

1 CS.1 COVER SHEET

2 CS.2 PROJECT OVERVIEW

3 AS.1 SITE PLAN

4 AD.1 DEMOLITION PLANS AND DEMOLITION DETAIL

5 AD.2 DEMOLITION EXTERIOR ELEVATIONS

6 A1.1 CELLAR & FIRST FLOOR PLANS

7 A1.2 SECOND & THIRD FLOOR PLANS

8 A3.1 EXTERIOR ELEVATIONS

9 A3.2 EXTERIOR ELEVATIONS

10 A8.1 WINDOW SCHEDULE

11 A8.2 WINDOW DETAILS

12 A8.3 WINDOW DETAILS

13 A8.4 TEMPORARY ENCLOSURE & REMOVABLE

SASH DETAILS

NXY

Snapshot

NXY

Text Box

COVER SHEET

NXY

Image

NXY

Text Box 02/28/2020

A/E ARCHITECTURE/ENGINEERING

ABA ARCHITECTURAL BARRIERS ACT

ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

ADA AMERICANS WITH DISABILITIES ACT

ADD ADDITION

ADMIN ADMINISTRATION

AFF ABOVE FINISHED FLOOR

AL ALUMINUM

APPROX APPROXIMATELY

AW AWNING

BLDG BUILDING

BLTS BOLTS

BO BOTTOM OF

C CASEMENT

CL CENTERLINE

CLO CLOSET

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CONTRACTING OFFICER

DH DOUBLE-HUNG

DIA/ø DIAMETER

DWGS DRAWINGS

EL/ELEV ELEVATION

EQ EQUAL

ETR EXISTING TO REMAIN

EX/EXT EXISTING

FCU FAN COIL UNIT

F FIXED

FF FINISHED FLOOR

GL GLASS, GLAZING

GWB GYPSUM WALL BOARD

HABS HISTORIC AMERICAN BUILDING SURVEY

HM HOLLOW METAL

HSR HISTORIC STRUCTURE REPORT

IBC INTERNATIONAL BUILDING CODE

IEBC INTERNATIONAL EXISTING BUILDING CODE

INT INTERIOR

LARPM LIQUID-APPLIED REINFORCED POLYMER MEMBRANE

LG LARGE

MAL MATERIAL

MIN MINIMUM

MAX MAXIMUM

MEP MECHANICAL/ELECTRICAL/PLUMBING

N/A NOT APPLICABLE

N.I.C. NOT IN CONTRACT

NO NUMBER

NPS NATIONAL PARK SERVICE

OC ON CENTER

OH OPPOSITE HAND

OZ OUNCE

PART PARTIAL

PT PRESSURE-TREATED

REF REFRIGERATOR

REQ'D REQUIRED

RM ROOM

SF SQUARE FEET

SH SINGLE-HUNG

SI SQUARE INCH

SIM SIMILAR

SM SMALL

SS STAINLESS STEEL

TECH TECHNICAL

TYP TYPICAL

U.N.O. UNLESS NOTED OTHERWISE

USPP UNITED STATES PARK POLICE

VENT VENTILATION

V.I.F. VERIFY IN FIELD

W/ WITH

W/OUT WITHOUT

WD WOOD

KEY TO ABBREVIATIONS

WINDOW TAG

DEMOLITION NOTE

DOOR TAG

DETAIL/ PARTIAL

SECTION

REFERENCE

ELEVATION

REFERENCE

KEY TO SYMBOLS

D.1

X A A1 A

A1

SIM

A1

SIM

X

1i

SECTION

REFERENCE

GENERAL NOTES

1. REFER TO DIVISION 1 AND DIVISION 2 SPECIFICATIONS.

2. COMPLY WITH HAZARDOUS MATERIALS SPECIFICATIONS 02 83 13.

3. COORDINATE EXTENT OF DEMOLITION WITH NEW AND REBUILT WORK.

4. REFER TO SPECIFICAITON SECTIONS 06 03 12 AND 05 52 00 FOR

TREATMENT OF WOOD WINDOW FRAMES, TRIM, SILLS, & SASHES

PLYWOOD

WOOD BLOCKING RIGID INSULATION

FLASHING

KEY TO MATERIALS

SAND, GROUT OR MORTAR FINISH WOOD

DEMOLITION SYMBOLS & NOTES

SCOPE OF WORK

APPLIES TO THE

ITEM SHOWN

WITH DASHED

LINES. SEE

DEMOLITION

DRAWINGS AND

NOTES FOR

EXTENT.

SCOPE OF

WORK APPLIES

TO THE ITEM

SHOWN

IDENTIFIED

EITHER IN THE

NOTE OR AT

THE SYMBOL.

THE FOLLOWING NOTES APPLY TO ALL DEMOLITION WORK WHETHER INDICATED ON THE DEMOLITION DRAWINGS OR REQUIRED

ELSEWHERE IN THE CONTRACT DOCUMENTS.

1.1 GENERAL REQUIREMENTS: THE FOLLOWING GENERAL REQUIREMENTS NOTES APPLY TO ALL DEMOLITION WORK. THE

NOTES ARE NOT SYMBOLICALLY REFERENCED ELSEWHERE IN THE DRAWINGS.

1.2 THE SCOPE OF THE ARCHITECTURAL DEMOLITION FOR THIS PROJECT, APART FROM SPECIFIED UNDER SECTION

"SELECTIVE DEMOLITION," IS SHOWN IN SHEETS NUMBERED AD1.1 AND AD1.2.

1.3 THE DEMOLITION AS INDICATED ON THE DRAWINGS APPLIES TO THE DEFINED SCOPE OF WORK. THE DRAWINGS, IN GENERAL, DO NO SPECIFICALLY ADDRESS DEMOLITION THAT IS DEPENDENT ON THE CONTRACTOR'S INDIVIDUAL "MEANS AND METHODS" OF EXECUTING THE WORK. THE REQUIREMENT FOR THIS DEMOLITION IS UNDER

SPECIFICATION SECTION "SELECTIVE DEMOLTION."

1.4 THE EXTENT OF DEMOLITION SHALL BE COORDINATED WITH THE NEW AND REBUILT WORK.

1.5 "EXTENT OF WORK" SYMBOLS ARE DEFINED AS FOLLOWS:

1.6 THE TERM "REMOVE" IS DEFINED IN THE SPECIFICATION SECTION "SELECTIVE DEMOLITION."

1.7 DURING DEMOLITION, PROVIDE TEMPORARY SUPPORT TO ADJACENT EXISTING CONSTRUCTION AND STRUCTURE TO HOLD

IN PLACE WITHOUT ANY MOVEMENT UNTIL NEW SUPPORTING WORK IS IN PLACE.

D.1

D.1 D.1

SCOPE OF

WORK

APPLIES TO

THE ENTIRE

OPENING FOR

THE ITEM OF

WORK

IDENTIFIED

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

PROJECT OVERVIEW

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

2 13

CS.2

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

NXY

Image

S 3RD ST.

C H E S T N U T

S T

STAGING AREA TO THE SOUTH OF

PROPERTY, COORDINATE FINAL

LOCATION W/ C.O.

HAZARDOUS MATERIAL

TO BE STORED MIN. 50

FT. FROM THE BUILDING

*SEE SPECIFICATIONS

GATE ACCESS AT CHESTNUT ST.

8'-8" CLEAR WIDTH V.I.F.

NO HEIGHT RESTRICTION

GATE ACCESS AT SOUTH 3 ST.

7'-8" CLEAR WIDTH V.I.F.

8'-2" CLEAR HEIGHT V.I.F.

MAINTAIN MIN. 6' CLEAR

GATE ACCESS AT SOUTH 3 ST.

7'-8" CLEAR WIDTH V.I.F.

8'-4" CLEAR HEIGHT V.I.F.

MAINTAIN ACCESS FROM FRONT

DOOR TO SIDEWALK. PROTECT FROM

OVERHEAD CONST.

FULL RAMP ACCESS AND OVERHEAD

PROTECTION MUST BE MAINTAINED

THROUGHOUT CONSTRUCTION

SITE WALL

14'-6" V.I.F.

8'-8" V.I.F.

V.I.F.

10'-9"

V.I.F.

14'-2"

50'-0"

MAINTAIN MIN. 6'-0" CLEAR

TRAVEL PATH THROUGHOUT CONST.

xxxx x xLIGHT POLE

TREE CANOPY

LIGHT POLE

S 3RD ST.

x x x x x x xxxx x x

TREE CANOPY

ROOF LINE ABOVE

1. PROTECT ADJACENT TREE CANOPY

THROUGHOUT CONSTRUCTION.

2. AVOID GRASS AREAS AND PROVIDE

PROTECTION OVER ALL WALKWAYS

THROUGHOUT CONSTRUCTION.

3. PROTECTION BELOW EQUIPMENT TO

BE MADE UP OF A TOP LAYER OF

3/4" EXTERIOR GRADE PLYWOOD, A

MIDDLE LAYER OF 1” RIGID

INSULATION, AND A BOTTOM LAYER

OF 3/4" EXTERIOR GRADE PLYWOOD.

GENERAL SITE NOTES

20 40

SCALE OF FEET

0 20

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

LANDSCAPE:

NAME

CITY, STATE

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :2

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

SITE PLAN

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

3 13

AS.1

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATESXXXXX

XXXXX

SCALE AAS.1

1 SITE PLAN

D.1

D.2

D.3

REMOVE EXTERIOR ROUND TRIM AT

JAMBS FOR REMOVAL OF WINDOW

SASHES

REMOVE PARTING TRIM FROM WINDOW

FRAME

REMOVE WINDOW SASHES FROM

FRAMES FOR RESTORATION

REMOVE INTERIOR WOOD TRIM AND

INT STORM SASHES FOR CLEANING

AND REINSTALLATION

REMOVE WEATHER STRIPPING FROM

FRAMES & WINDOW SASHES

REMOVE PAINT FROM WINDOW

FRAMES, TRIM, & SILLS DOWN TO

BARE WOOD

REMOVE WINDOW ROLLER SHADES

FROM EACH WINDOW, CATALOG,

CLEAN, AND SALVAGE FOR

REINSTALLATION

D.4

D.5

D.6

D.7

D.8

D.9

D.10

D.11

D.12

REMOVE SEALANT AND BACKER ROD

JOINT FILLER MATERIAL FROM WINDOW

FRAME PERIMETERS

REMOVE PAINT TO BARE WOOD; REMOVE

GLAZING PUTTY, GLAZING STOPS, GLASS

FROM EACH SASH; SALVAGE GLASS FOR

REINSTALLATION. WINDOW SASHES TO BE

STRIPPED TO BARE WOOD, READY FOR

RESTORATION.

REMOVE WOOD ROT FROM WINDOW

SASHES; LEAVE SOUND WOOD READY FOR

REPAIRS/REPLACEMENT

REMOVE AND SALVAGE CELLAR AREA WAY

DOORS. PROVIDE SECURE, WEATHER

RESISTANT ENCLOSURE AT AREA WAYS

SIMILAR TO DETAILS 2 & 3 ON A8.4

REMOVE LOOSE PAINT FROM IRON BARS

PREPARE FOR NEW FINISH

5. ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.

014004

006 007

001 017

D.3

TYP

D.7

TYP

VAULT #2

EAST HALL

VAULT #1

VAULT #4

NORTH HALL

MECH. RM.

CENTER HALL

09VAULT #3

SOUTH HALL

VAULT #6

06VAULT #5

D.12

TYP

D.12

TYP

D.3

D.7 D.12

TYP

TYP

TYP

124 123 122 120 119 118

107 108 110 111

D.11 D.11

D.7

D.3

TYP

TYP

EXHIBIT AREA

STORAGE

101A

VESTIBULE

D.3D.7

TYP TYP

224 223 218219220222

206 207 208 210 212211209

D.7

D.3

TYP

TYP

OFFICE

213A

OFFICE

213B

OFFICE

213C

OFFICE

OFFICE

STORAGE

CONF. RM.

OFFICE

MEN'S

WOMEN'S

OFFICE

OFFICE

211A

OFFICE

OFFICE

D.7

D.3

TYP

TYP

306 307 308 310 311 312

D.7

D.3

TYP

TYP

LUNCH ROOM

KITCHEN

MECH. RM.

ACCESSIONS

LIBRARY

STORAGE

CLOSET

302A

STORAGE

303B

STORAGE

303A

STAIR HALL

NORTH HALL

D.7 D.3

TYP

TYP

A8.2

SIM

D.4

D.3

D.5

D.2

D.1

D.6

D.10

INTERIOR

EXTERIOR

D.9

D.8

1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL

WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED

OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON

DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH

WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION

TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.

2. ALL WINDOW WEATHER STRIPPING SHALL BE REMOVED UNLESS NOTED OTHERWISE.

3. SEE DIVISION 02 SPECIFICATIONS FOR ABATEMENT OF ASBESTOS CONTAINING

MATERIALS AND LEAD BASED PAINT.

4. INSTALL TEMPORARY WINDOW PROTECTION (SEE DRAWING A8.4)

GENERAL DEMOLITION NOTES

12 12

SCALE OF INCHES

6 0

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

SCALE B

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

DEMOLITION PLANS AND

DEMOLITION DETAIL

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

4 13

AD.1

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AAD.1

1 CELLAR DEMOLITION PLAN

SCALE AAD.1

2 FIRST FLOOR DEMOLITION PLAN

SCALE AAD.1

3 SECOND FLOOR DEMOLITIONPLAN

SCALE AAD.1

4 THIRD FLOOR PLAN DEMOLITION PLAN

SCALE BAD.1

5 TYP DEMO DETAIL AT JAMB

8 24

SCALE OF FEET

0 8 16

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

224 223 222 221 220 219 218

118119120122123124

TRANSOM WINDOW AND DOOR N.I.C.

014004

BEYONDBEYOND

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

317 316 315 314 313

213214215216217

117 116 115 114

015017

EXT STAIR AND

RAMP BEYOND

CELLAR AREA-WAY DOOREXT IRON BARS IN FRONT

OF CELLAR WINDOWS,

TYP

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

305 304 303 302 301

201202203205 204

104 103 102 101

001003

EXT STAIR AND

RAMP BEYOND

CELLAR AREA-WAY DOOR EXT IRON BARS IN FRONT

OF CELLAR WINDOWS,

TYP

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

311312 310 309 308 307 306

206207208210211212

111 110 108 107

007 006

METAL LOUVERS N.I.C.

TRANSOM WINDOW AND DOOR N.I.C.

EXT STAIR AND RAMP

AT WEST ENTRANCE

BEYOND

BEYOND

EXT IRON BARS IN FRONT

OF CELLAR WINDOWS,

TYP

1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL

WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED

OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON

DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH

WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION

TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.

2. ALL WINDOW WEATHER STRIPPING SHALL BE REMOVED UNLESS NOTED OTHERWISE.

3. SEE DIVISION 02 SPECIFICATIONS FOR ABATEMENT OF ASBESTOS CONTAINING

MATERIALS AND LEAD BASED PAINT.

4. INSTALL TEMPORARY WINDOW PROTECTION (SEE DRAWING A8.4)

GENERAL DEMOLITION NOTES

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

DEMOLITION EXTERIOR

ELEVATIONS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

5 13

AD.2

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AAD.2

2 DEMO EAST ELEVATION

SCALE AAD.2

1 DEMO NORTH ELEVATION

SCALE AAD.2

3 DEMO SOUTH ELEVATION

SCALE AAD.2

4 DEMO WEST ELEVATION

8 24

SCALE OF FEET

0 8 16

A .2 2

A3.2

A .12

004 014

METAL LOUVERS

N.I.C.

VAULT #2

VAULT #1

VAULT #4

VAULT #3

VAULT #5

MECH. RM.

VAULT #6

EAST HALL

CENTER HALL

SOUTH HALL

NORTH HALL

006 007

001 017

IRON BARS IN FRONT

OF CELLAR WINDOWS

TYP

A .2 2

A3.2

A .12

A3.1

A8.3

A8.3

SIM

EXT RAMP AND STAIR

VESTIBULE

EXHIBIT AREA

STORAGE

101A

STAIR HALL

124 123 122 120 119 118

114104

107 108 110 111

EXT PORTICO

ROOF ABOVE

1. PROVIDE NEW BACKER ROD AND SEALANT AT WINDOW FRAME PERIMETERS

2. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW FRAME AND TRIM

WHERE ROT HAS CAUSED DAMAGE

3. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW SASHES.

4. PRIME WOOD SURFACES OF FRAMES AND TRIM

5. PRIME WOOD SURFACES OF WINDOW SASHES PRIOR TO REINSTALLING WINDOW

GLAZING

6. INSTALL GLAZING WITHIN A GLAZING BED, INSTALL GLAZING POINTS, GLASS, AND

GLAZING PUTTY. PRIME GLAZING PUTTY

7. PAINT WINDOW SASHES AND PUTTY – 2 COATS

8. REINSTALL WINDOW SASHES WITHIN FRAME

9. REINSTALL INT STORM WINDOW UNITS AFTER CLEANING AND INSTALL NEW WOOD

TRIM TO MATCH EXISTING. PRIME AND PAINT TO MATCH.

10. SEE DRAWING A8.1 AND SPECIFICATIONS FOR WINDOW SPECIFIC TREATMENT

11. REPLACE ROTTEN WOOD AT CELLAR AREA-WAY DOORS. REMOVE PAINT TO BARE

WOOD. REFURBISH HARDWARE, PRIME AND PAINT (2 COATS) DOORS TO MATCH

EXT. REINSTALL DOORS AND HARDWARE. SEE DRAWING A8.3 DETAILS 2 AND 3

ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.

1. ALL WINDOW SASHES, FRAMES, SILLS, AND TRIM SHALL BE PRIMED AND

PAINTED WITH TWO (2) COATS OF PAINT. WINDOW SASH JAMBS SHALL ONLY

RECEIVE A SINGLE PRIMER COAT OF PAINT. U.N.O.

2. ALL RESTORED WINDOW SASHES SHALL BE REINSTALLED WITHIN THEIR ORIGINAL

LOCATION, WITH ORIGINAL HARDWARE, AND NEW WEATHER STRIPPING UNLESS

NOTED OTHERWISE.

3. REINSTALL ROLLER SHADES IN THEIR ORIGINAL WINDOW LOCATION.

4. INSTALL PARTING TRIM AND ROUND EXTERIOR TRIM FOLLOWING THE

INSTALLATION OF WEATHER STRIPPING AND WINDOW SASHES IN FRAMES.

NEW CONSTRUCTION NOTES

8 0 8 16

SCALE OF FEET

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :0

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

CELLAR & FIRST FLOOR

PLANS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

6 13

A1.1

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA1.1

1 CELLAR PLAN

SCALE AA1.1

2 FIRST FLOOR PLAN

A .2 2

A3.2

A .12

A3.1

OPEN TO BELOW

OFFICE

OFFICE

213A

OFFICE

213B

OFFICE

213C

OFFICE

OFFICE

OFFICE

211A

OFFICE

OFFICE

WOMEN'S

MEN'S

OFFICE

CONF. RM.

STORAGE

ROTUNDA GALLERY

206 207 208 209 210 211 212

218219220221222223224

EXT PORTICO

ROOF ABOVE

A .2 2

A3.2

A .12

A3.1

LIBRARY

ACCESSIONS

MECH. RM.

LUNCH ROOM

STORAGE

303B

STORAGE

303A

KITCHEN

CLOSET

302A

STORAGE

NORTH HALL

STAIR HALL

306 307 308 309 310 311 312

317301

EXT PORTICO

ROOF ABOVE

1. PROVIDE NEW BACKER ROD AND SEALANT AT WINDOW FRAME PERIMETERS

2. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW FRAME AND TRIM

WHERE ROT HAS CAUSED DAMAGE

3. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW SASHES.

4. PRIME WOOD SURFACES OF FRAMES AND TRIM

5. PRIME WOOD SURFACES OF WINDOW SASHES PRIOR TO REINSTALLING WINDOW

GLAZING

6. INSTALL GLAZING WITHIN A GLAZING BED, INSTALL GLAZING POINTS, GLASS, AND

GLAZING PUTTY. PRIME GLAZING PUTTY

7. PAINT WINDOW SASHES AND PUTTY – 2 COATS

8. REINSTALL WINDOW SASHES WITHIN FRAME

9. REINSTALL INT STORM WINDOW UNITS AFTER CLEANING AND INSTALL NEW WOOD

TRIM TO MATCH EXISTING. PRIME AND PAINT TO MATCH.

10. SEE DRAWING A8.1 AND SPECIFICATIONS FOR WINDOW SPECIFIC TREATMENT

11. REPLACE ROTTEN WOOD AT CELLAR AREA-WAY DOORS. REMOVE PAINT TO BARE

WOOD. REFURBISH HARDWARE, PRIME AND PAINT (2 COATS) DOORS TO MATCH

EXT. REINSTALL DOORS AND HARDWARE. SEE DRAWING A8.3 DETAILS 2 AND 3

ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.

1. ALL WINDOW SASHES, FRAMES, SILLS, AND TRIM SHALL BE PRIMED AND

PAINTED WITH TWO (2) COATS OF PAINT. WINDOW SASH JAMBS SHALL ONLY

RECEIVE A SINGLE PRIMER COAT OF PAINT. U.N.O.

2. ALL RESTORED WINDOW SASHES SHALL BE REINSTALLED WITHIN THEIR ORIGINAL

LOCATION, WITH ORIGINAL HARDWARE, AND NEW WEATHER STRIPPING UNLESS

NOTED OTHERWISE.

3. REINSTALL ROLLER SHADES IN THEIR ORIGINAL WINDOW LOCATION.

4. INSTALL PARTING TRIM AND ROUND EXTERIOR TRIM FOLLOWING THE

INSTALLATION OF WEATHER STRIPPING AND WINDOW SASHES IN FRAMES.

NEW CONSTRUCTION NOTES

8 0 8 16

SCALE OF FEET

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :0

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

SECOND & THIRD FLOOR

PLANS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

7 13

A1.2

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA1.2

1 SECOND FLOOR PLAN

SCALE AA1.2

2 THIRD FLOOR PLAN

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

A8.1

LOCATE WINDOW MOCK

UPS IN OPENINGS

317,217,117, AND 017

EXT STAIR

AND RAMP

BEYOND

CELLAR AREA-WAY DOOR

SEE DETAILS 2 AND 3 ON DWG A8.3

117 116 115 114

217 216 215 214 213

313314315316317

017 015

EXT IRON BARS IN

FRONT OF CELLAR

WINDOWS,

TYP

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

TRANSOM WINDOW AND DOOR N.I.C.

014004

BEYONDBEYOND

124 123 122 120 119 118

224 223 218219220222 221

1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL

WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED

OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON

DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH

WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION

TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.

GENERAL NOTE

8 0 8 16

SCALE OF FEET

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :0

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

EXTERIOR ELEVATIONS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

8 13

A3.1

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA3.1

2 NORTH ELEVATION

SCALE AA3.1

1 EAST ELEVATION

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

EXT STAIR AND

RAMP BEYOND

CELLAR AREA-WAY DOOR

SEE DETAILS 2 AND 3 ON DWG A8.3

101102103104

201202203204205

301302303304305

003 001

EXT IRON BARS IN FRONT

OF CELLAR WINDOWS,

TYP

FIRST FLOOR

0.00'

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

ROOF

45.33'

METAL LOUVERS N.I.C.

A8.1

TRANSOM WINDOW AND DOOR N.I.C.

EXT STAIR AND

RAMP AT WEST

ENTRANCE

BEYOND

BEYOND

107108110111

206207208210212 211

306307308310311312 309

007 006

EXT IRON BARS IN

FRONT OF CELLAR

WINDOWS,

TYP

1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL

WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED

OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON

DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH

WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION

TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.

GENERAL NOTE

8 0 8 16

SCALE OF FEET

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

EXTERIOR ELEVATIONS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

9 13

A3.2

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA3.2

2 SOUTH ELEVATION

SCALE AA3.2

1 WEST ELEVATION

SECOND FLOOR

19.25'

THIRD FLOOR

33.00'

V.I.F.

4'-4 1/2"

V .I .F

V .I .F

V .I .F

V .I .F

V .I .F

V .I .F

V .I .F

B

A2

A1

D

V.I.F.

4'-11"

V.I.F.

4'-4 1/2"

A8.2

A8.2

A8.3

A8.3

A8.3

A8.3

A8.2

SIM

A8.2

SIM

A8.3

SIM

A8.3

SIM

A8.2

SIM

A8.2

SIM

V.I.F.

4'-4 1/2"

SIM

A8.3

SECOND FLOOR

19.25'

C1C2 C2

V .I .F

12'-2 1/2" V.I.F.

A8.2

SIM

A8.3

SIM

A8.2

SIM

DOUBLE HUNG

V.I.F.

2'-2 1/4"

V.I.F.

5'-6"

V.I.F.

2'-2 1/4"

2 6

SCALE OF FEET

0 2 4

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

WINDOW SCHEDULE

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

10 13

A8.1

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA8.1

WINDOW ELEVATION

TYPES A, B, AND D

WINDOW SCHEDULE

WINDOW

NO.

WINDOW

TYPE

TREATMENT LEVEL AT:

(REFER TO SPECIFICATION SECTION 06 03 12 FOR TREATMENT LEVEL)

COMMENTSWINDOW SASH FRAME & TRIM SILL

001 D 1 2 AT HEAD 1 INTERIOR AND EXTERIOR

003 D 2 NOTE 9

006 D 2 2 2

007 D 2 BOTTOM & SIDE SASH 1 2

008 LV 11 - - - -

009 LV 11 - - - -

015 D 1 1 1

017 D 1 1 1 NOTE 7

101 A1 1 1 1

102 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2

103 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2

104 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2

107 A1 2 SASH MUNTIN 1 1

108 A1 2 FILL SCREW HOLE 1 1 INTERIOR, 2 EXTERIOR

110 A1 2 LOWER SASH MUNTIN & FRAME 1 1

111 A1 2 LOWER SASH 1 1 INTERIOR, 2 EXTERIOR

114 A1 1 3 AT LOWER JAMBS 1 NOTES 2 & 6

115 A1 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

116 A1 1 1 3 NOTE 2

117 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2

118 A1 1 1 2 INTERIOR, 2 EXTERIOR

119 A1 1 1 1 INTERIOR, 2 EXTERIOR

120 A1 1 1 1 INTERIOR, 2 EXTERIOR NOTE 3

122 A1 1 1 1

123 A1 1 1 1 INTERIOR, 2 EXTERIOR

124 A1 2 AT MUNTIN LOWER SASH 1 2 INTERIOR, 2 EXTERIOR NOTE 13 AT LOWER

SASH

201 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

202 A2 1 1 2 INTERIOR AND EXTERIOR

203 A2 2 LOWER SASH 1 2 INTERIOR AND EXTERIOR

204 A2 1 1 2 INTERIOR AND EXTERIOR

205 A2 1 1 3 INTERIOR

206 A2 2 BOTTOM SASH 3 INTERIOR, 2 EXTERIOR

207 A2 1 1 2 INTERIOR AND EXTERIOR

208 A2 2 UPPER SASH MUNTIN 1 1 INTERIOR, 2 EXTERIOR NOTE 4

209 C1 1 2 JAMB CRACK 2 INTERIOR, 3 EXTERIOR NOTE 5

209 A C2 1 1 2 INTERIOR, 2 EXTERIOR NOTE 5

209 B C2 1 2 JAMB CRACK 2 INTERIOR, 2 EXTERIOR NOTE 5

210 A2 2 UPPER SASH MUNTIN 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 3

211 A2 1 1 2 INTERIOR, 2 EXTERIOR

212 A2 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2

213 A2 2 UPPER & BOTTOM SASH 1 2 INTERIOR, 2 EXTERIOR

214 A2 1 1 2 INTERIOR

215 A2 2 SASH MUNTIN AT LOWER SASH 1 1 INTERIOR, 3 EXTERIOR NOTES 2, 3, & 8

216 A2 1 1 3 INTERIOR, 2 EXTERIOR

217 A2 1 1 2 INTERIOR AND EXTERIOR

218 A2 1 1 2 INTERIOR AND EXTERIOR

219 A2 1 1 1 INTERIOR, 2 EXTERIOR NOTE 8

220 A2 1 1 1 INTERIOR, 2 EXTERIOR NOTE 8

221 A2 2 UPPER SASH 1 2 INTERIOR, 2 EXTERIOR

222 A2 1 1 2 INTERIOR, 2 EXTERIOR

223 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

224 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

301 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2, 11, & 12

302 B 1 1 1 INTERIOR AND EXTERIOR NOTES 10 & 11

303 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

304 B 1 1 1 INTERIOR AND EXTERIOR

305 B 2 BOTTOM SASH 3 AT SASH PULLY 2 INTERIOR, 3 EXTERIOR NOTE 2

306 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 14

307 B 1 3 AT HEAD TRIM 2 INTERIOR, 2 EXTERIOR

308 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

309 B 1 1 1 INTERIOR AND EXTERIOR

310 B 1 3 INTERIOR 2 INTERIOR AND EXTERIOR NOTES 1,2, & 12

311 B 1 1 1 INTERIOR, 3 EXTERIOR NOTES 1 & 2

312 B 1 2 AT HEAD TRIM 1 INTERIOR, 3 EXTERIOR NOTES 1 & 2

313 B 1 1 1 INTERIOR AND EXTERIOR NOTE 1

314 B 2 TOP & BOTTOM SASH 1 2 INTERIOR, 3 EXTERIOR NOTES 1 & 2

315 B 1 2 AT HEAD 2 INTERIOR, 3 EXTERIOR NOTE 2

316 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2

317 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 12

WINDOW NOTES:

1. MODIFY WINDOW SASH TO ACCOMODATE EASY REMOVAL FOR

HVAC EQUIPMENT. SEE DETAILS ON A8.4

2. REMOVE ROTTING SILL AT EXTERIOR, REBUILD SOLID WOOD

SILL, SLOPE AWAY FROM WINDOW

3. REPLACE BROKEN OR MISSING GLASS

4. PATCH DAMAGED SASH FRAME AT LOCKING HARDWARE

5. REINSTALL SASHES WITH UPPER SASH OUTBOARD AND LOWER

SASH TO THE INTERIOR. INSTALL WEATHER STRIPPING TO

ACCOMODATE SASH LOCATION

6. ADJUST JAMB OF INTERIOR STORM SASH TO PREVENT SASH

FROM FALLING, REPLACE SIDE RAILS FOR PROPPER FUNCTION

7. COORDINATE WINDOW RESTORATION WITH EXISTING WIRES

THROUGH WINDOW FRAME AT JAMB

8. PROVIDE BRASS SASH HANDLE TO MATCH EXISTING

9. NOT USED

10. PATCH STONE SILL WHERE WEATHERING HAS CAUSED A

CHANNEL TO PREVENT WATER FROM RUNNING BACK TOWARDS

THE WINDOW SILL

11. PATCH INTERIOR JAMB AT WINDOW WASHER ANCHOR

FASTENER PLUG

12. REPLACE UPPER STORM WINDOW SASH GLAZING AT SECURITY

CAMERA LOCATIONS

13. REPLACE BROKEN STORM GLASS

14. REPLACE SASH WEIGHT CHAIN TO MATCH EXISTING

SCALE AA8.1

2 WINDOW ELEVATION - TYPE C

DOUBLE HUNG

DOUBLE HUNG

DOUBLE HUNG

CASEMENT

WOOD SASH

GLASS

EXT. ARCHITRAVE

EXT. BLOCKING

EXT. STONE LENTIL

FACE N.I.C

SEALANT

BRONZE WEATHER

STRIP

GLAZING PUTTY

REPLACE WOOD

TRIM, MATCH EXT

ALUM. STORM

SASH FRAME

GLAZING PUTTY

GLASS

WOOD SASH

EXT SASH LOCK

REFURBISHED

BRONZE WEATHER

STRIP

GLAZING PUTTY

GLASS

WOOD SASH

PARTING STRIP

INTERIOREXTERIOR

INTERIOREXTERIOR

GLASS

EXT OR NEW WOOD SILL

SLOPED AWAY FROM

GLAZING

BACKER ROD AND SEALANT

WOOD SASH

EXT. WOOD SILL

EXT. STONE SILL

N.I.C.

BRONZE WEATHER STRIP

GLAZING PUTTY

REPLACE WOOD TRIM,

MATCH EXT PROFILE, TYP.

ALUM. STORM SASH FRAME

A8.2

PLASTIC SHIM

ANCHOR NEW WOOD SILLS

TO SUBSTRATE THROUGH

VERTICAL SURFACE

WOOD PLUG FLUSH

W/ FACE OF SILL

EXT WOOD TRIM

PARTING STRIP, BEYOND

EXTERIOR INTERIOR

WOOD MUNTIN

EXT OR NEW GLASS

V .I .F

SETTING BED

GLAZING PUTTY

V.I.F.

INTERIOREXTERIOR

VARIES

WOOD TRIM, PROFILE

TO MATCH EXT

PLUG FASTENER

HEADS, SAND FLUSH

W/ ADJACENT TRIM

FASTENERS 3" FROM

ENDS AND EVERY

18" O.C., TYP

EXTERIOR

VARIES

3/4"

1/2"

V.I.F.

4 1/2"

V .I .F

WOOD FASTENERS

3" FROM ENDS

AND 8" O.C. MAX

WOOD PLUG FLUSH

W/ FACE OF SILL

BACKER ROD AND

SEALANT

PLASTIC SHIM

PARTING STRIP

BEYOND

BRICK MOLD

TRIM BEYOND

EXTERIOR INTERIOR

V .I .F

1/2" VARIES

WOOD

PARTING

STRIP

V.I.F.

WOOD TRIM

TO MATCH

EXT PROFILE

EXTERIOR

INTERIOR

1. SEE SCHEDULE ON A8.1 FOR WINDOWS TO RECEIVE NEW MATERIALS

2. REMOVE ALL HARDWARE, REFURBISH PER SPEC 06 13 12, REINSTALL

GENERAL NOTES

1 0 1 2

SCALE OF FEET

12 12

SCALE OF INCHES

6 0

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

SCALE B

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

WINDOW DETAILS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

11 13

A8.2

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA8.2

1 TYP DETAIL AT HEAD AND MEETING RAIL

SCALE AA8.2

4 TYP DETAIL AT SILL

SCALE BA8.2

2 TYP MUNTIN

SCALE BA8.2

5 DETAIL

SCALE BA8.2

3 DETAIL

SCALE BA8.2

6 DETAIL

V .I .F

WOOD SASH

GLASS

GLAZING PUTTY

EXT. WOOD ARCH

BRONZE

WEATHERSTRIPPING

W/ VINYL SEAL

INTERIOREXTERIOR EXT CEM. SILL

WOOD SILL

GLAZING PUTTY

WOOD SASH

GLASS

BRONZE WEATHER STRIP

SEALANT, TYP

BRONZE

WEATHERSTRIPPING

W/ VINYL SEAL

INTERIOR

EXTERIOR

V .I .F

V .I .F

WOOD SASH

GLASS

GLAZING PUTTY

WOOD SILL

PLASTIC SHIM

EXT MASONRY

SILL

V.I.F.

1 1/2"

BACKER ROD

AND SEALANT

BRONZE WEATHER

STRIP

V.I.F.

BRONZE WEATHER

STRIPPING

W/ VINYL SEAL

WOOD SILL STOP

INTERIOR

EXTERIOR

V.I.F.

3'-3 1/2"

V .I .F

V .I .F

V .I .F

E Q

E Q

V .I .F

V .I .F

"REPLACE ROTTEN

WOOD BOARDS ON

DOOR 004

EXT. STONE LINTEL

EXT. BRICK WALL

SEALANT

EXT. STONE TOOLING

V.I.F.

2 1/2"

V.I.F.

8 1/2"V.I.F.

3 1/2"

EXT FASTENERS

IRON STRAP HINGE

EXT FASTENERS

EXT IRON STRAP HINGE

WOOD T&G BOARDS

WIDTH VARIES

ANCHORS

WOOD BLOCKING

SEALANT

RESTORE WOOD CELLAR AREA-WAY

DOORS, REPLACE ROTTING WOOD, STRIP

PAINT TO BARE WOOD, PRIME AND

PAINT - 2 COATS

INTERIOR

EXTERIOR

GLASS

GLAZING PUTTY

WOOD SASH

WEATHER STRIP

V.I.F.

1 3/4"

V.I.F.

2 1/4"

EXTERIOR

GLASS

REINSTALL WOOD SASH

EXT BLOCKING

EXT SPLAYED

WOOD JAMB

PARTING STRIP,

MATCH EXT, GLUE

AND FASTEN W/

FINISH NAILS

PARTING TRIM

BEYOND

EXT. STONE

SILL N.I.C.

GLAZING PUTTY

EXT. LEAD

SASH WEIGHTS

REINSTALLED EXT

WOOD TRIM

REINSTALLED ALUM.

STORM SASH FRAME

A8.2

SIM

BRONZE WEATHER STRIP

EXT. MASONRY

JAMB

EXTERIOR

INTERIOR

SEALANT

1. SEE SCHEDULE ON A8.1 FOR WINDOWS TO RECEIVE NEW MATERIALS

2. REMOVE ALL HARDWARE, REFURBISH PER SPEC 06 13 12, REINSTALL

GENERAL NOTES

8 0 8 16

SCALE OF FEET

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

WINDOW DETAILS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

12 13

A8.3 Designer

Author

Checker

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE AA8.3

4 HEAD DETAIL AT CASEMENT WINDOW

SCALE AA8.3

6 JAMB DETAIL AT CASEMENT WINDOW

SCALE AA8.3

5 SILL DETAIL AT CASEMENT WINDOW

SCALE BA8.3

3 CELLAR AREA-WAY DOOR PLAN DETAIL

SCALE BA8.3

2 CELLAR AREA-WAY DOOR SECTION DETAIL

SCALE AA8.3

7 MEETING STILE AT CASEMENT WINDOW

SCALE AA8.3

1 TYP DETAIL AT JAMB

BACKER ROD

PLYWOOD

5/8"

RIGID INSULATION

2"

WOOD FRAMING

2X4

V .I .F

V A R

IE

S

WOOD FRAMING

2x4

BACKER ROD

WOOD FRAMING

WOOD BLOCKING

WOOD BLOCKING

WOOD BLOCKING

EXT WINDOW HEAD

FRAME (SHOWN WITH

SASHES REMOVED)

INTERIOR EXTERIOR

SCAFFOLDING BEYOND

COORD. WITH SCAFOLDING

PT 3/4" PLYWOOD

ENCLOSURE FENCE, PRIMED

AND PAINTED,

C.O. TO SELECT COLOR

SEE SPEC SECTION 01 50 00

2X4 PT WOOD

KICKER, 8' O.C. MAX

50 LBS. SAND BAG

2X4 PT MID-HEIGHT

WOOD FRAMING

3/4" EXT GRADE PLYWOOD

2X4 PT WOOD FRAMING

TYP.

2X PT WOOD BLOCKING

2'-0"

2X4 PT WOOD KICKER

3/4" PT PLYWOOD ON GRADE

50 LBS SAND BAG

2X4 PT WOOD FRAMING

2X PT WOOD BLOCKING4'-0" +/-

V .I .F

V A R

IE

S

EXT WALL

EXT WOOD

CASING TRIM

FELT AT ALL

LOCATIONS

WHERE BLOCKING

IS AGAINST EXT

CONSTRUCTION

2X BLOCKING

BACKER ROD

INTERIOREXTERIOR

WOOD SASH

GLASS

ALUM ANGLE TRIM 1" X

1" X 1/8" FASTENED TO

WINDOW SURROUND, 3

FASTENERS PER SIDE

ALUM. STORM SASH

FRAME W/OUT FASTENERS

GLAZING PUTTY

GLASS

WOOD SASH

EXT SASH LOCK

REFURBISHED

REMOVE PARTING STRIP

AT UPPER SASH, INFILL

W/ WOOD FILL, AND TRIM

FLUSH W/ JAMB AND

HEAD FRAME

GLASS

WOOD SASH

EXT. WOOD SILL

ALUM ANGLE TRIM 1" X 1" X 1/8"

FASTENED TO WINDOW SURROUND,

3 FASTENERS PER SIDE

ALUM. STORM SASH FRAME W/OUT

FASTENERS

REMOVE INT WOOD TRIM, FLUSH

W/ SILL AND JAMB FRAME

PARTING STRIP BEYOND

INTERIOREXTERIOR

INTERIOREXTERIOR

INTERIOREXTERIOR

REMOVE INT WOOD TRIM,

FLUSH W/ SILL AND

JAMB FRAME

HASPE, HANGER

BOLT, AND

BUTTERFLY FASTENER

BEYOND, (4 PER

LOWER SASH)

2 0 2 4

SCALE OF FEET

1 0 1 2

SCALE OF FEET

12 12

SCALE OF INCHES

6 0

A/E FIRM - GWWO

TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

PRIME/ARCH:

GWWO, INC.

BALTIMORE, MD

SUB SHEET NO.DESIGNED:

CADD:

TECH. REVIEW:

DATE:

SCALE A

SCALE B

SCALE C

:4 :1

P M

C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t

TEMPORARY ENCLOSURE &

REMOVABLE SASH DETAILS

INDEPENDENCE NATIONAL HISTORICAL PARK

153035

224447

13 13

A8.4

BCW

NY

MLP

02/28/2020

FIRST BANK OF THE UNITED STATES

SCALE BA8.4

2 TYP. TEMPORARY WINDOW ENCLOSURE SECTION

SCALE BA8.4

3 TYP. TEMPORARY WINDOW ENCLOSURE PLAN

SCALE C

A8.4

SITE FENCE PLAN

SCALE C

A8.4

SITE FENCE SECTION

SCALE AA8.4

HEAD, MEETING RAIL, SILL DETAIL

AT REMOVABLE WINDOW TYPE C

Sheets
CS.1 - COVER SHEET
CS.2 - PROJECT OVERVIEW
AS.1 - SITE PLAN
AD.1 - DEMOLITION PLANS AND DEMOLITION DETAIL
AD.2 - DEMOLITION EXTERIOR ELEVATIONS
A1.1 - CELLAR & FIRST FLOOR PLANS
A1.2 - SECOND & THIRD FLOOR PLANS
A3.1 - EXTERIOR ELEVATIONS
A3.2 - EXTERIOR ELEVATIONS
A8.1 - WINDOW SCHEDULE
A8.2 - WINDOW DETAILS
A8.3 - WINDOW DETAILS
A8.4 - TEMPORARY ENCLOSURE & REMOVABLE SASH DETAILS

File details come from the government source that posted it. Updated .