WS PROJECT(CONSTRUCTION) - DRAWINGS - 03-05-20.pdf
PDF 4 MB Posted
- Attached to
- Rehabilitate First Bank Windows, Sills and Trim
- Solicitation number
- 140P4220R0019
About this file
This document package includes construction drawings and specifications for the rehabilitation of windows, sills, and trim at the First Bank of the United States building within Independence National Historical Park. The project involves restoring all exterior wood windows through treatments such as replacing rotten wood, rebuilding solid wood sills, reglazing sashes, and refurbishing hardware. Interior storm windows will also be cleaned and reinstalled with new matching trim. Temporary enclosures and removable sashes are specified to facilitate HVAC equipment access. The solicitation is available through the National Park Service Northeast Region for qualified firms to rehabilitate the historic windows per the Secretary of the Interior's Standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P4220R0019_Amd_0002.pdf | ||
| Rehabilitate First Bank Windows_0002.pptx | PPTX presentation | |
| Hazardous Materials Survey Report First National Bank_0001.pdf | ||
| First Bank Windows Questions and Answers_0001.pdf | ||
| Sol_140P4220R0019_Amd_0001.pdf | ||
| PROJECT(CONSTRUCTION) - SPECIFICATIONS - 03-05-20.pdf | ||
| References Worksheet.doc | DOC document | |
| Form B.docx | DOCX document | |
| Bid Guarantee SF24-16d.pdf | ||
| Wage Determination PA20200003.pdf | ||
| PAYMENT BOND SF25A-16d.pdf | ||
| Sol_140P4220R0019.pdf | ||
| PERFORMANCE BOND SF25-16d1 (1).pdf | ||
| Form A.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FAIRMOUNT AVE.
N D
S T
B R O A D
S T
T H
S T
T H
S T
R D
S T
T H
S T
WALNUT ST.
SPRING GARDEN ST.
DIAMOND
LEHIGH
ALLEGHENY AVE.
G E R M A N T O W N
A V E
. WYOMING AVE.
H E N R Y
A V E
W
IS
S A H
IC
K O N
A V E
PINE ST.
SOUTH ST.
CHESTNUT
ST.
RACE ST.
AVE.
ST.
CECIL
MOORE
AVE.
B E L M O N T
A V E
T H
S T
R
ID
G E
A V E
ERIE AVE.
R
IS
IN
G
S U N A V E
HAVERFORD
AVE.
ERIE AVE.
V.C.
HQ.
INDEPENDENCE
NATIONAL
HISTORICAL
PARK
PHILADELPHIA
KOSCIUSZKO
MEMORIAL
EDGAR ALLAN
POE N.H.S.
DESHLER-MORRIS
HOUSE
∅0.0879
WALNUT STREET
CHESTNUT STREET
MARKET STREET
ARCH STREET
RACE STREET
VINE STREET
SPRUCE STREET
F R O N T
S T R E E T
S E C O N D
S T R E E T
T H
IR
D
S T R E E T
F O U R T H
S T R E E T
F
IF
T H
S T R E E T
S
IX
T H
S T R E E T
S E V E N T H
S T R E E T
BENJAMIN FRANKLIN BRIDGE
DOCK
LOCUST STREET
NEW STREET
PARKING
GARAGE
D O C K
S T R E E T
ADMINISTRATION
OFFICES
WASHINGTON
SQUARE
WALNUT STREET
T H
IR
D
S T R E E T
S E C O N D
S T R E E T
MARKET STREET
ARCH STREET
S T
MAINTENANCE
FACILITY
TO
THADDEUS KOSCIUSZKO
NATIONAL MEMORIAL
INDEPENDENCE
HALL
LIBERTY
BELL
PAVILLION
TO
EDGAR ALLAN
POE NHS
CAMDEN
DELAWARE
RIVER
SCHUYLKILL
RIVER
NEW
JERSEY
PENNSYLVANIA
UNESCO
HQ.
V.C.
LEGEND
INDEPENDENCE NATIONAL HISTORICAL PARK
SCALE OF MILES
01 1
SCALE OF FEET
SCALE OF METERS
WORLD HERITAGE SITE
PARK
HEADQUARTERS
STATE
LINE
VISITOR
CENTER
PARK
BOUNDARY
REHABILITATE WINDOWS, SILLS, AND TRIM AT FIRST BANK OF THE UNITED STATES
THIS PROJECT
FIRST
BANK
A/E FIRM - GWWO Mark Sheet REVISION Date Initial QUALITY DESIGN CERTIFICATION Prepared in Accordance with Design
Development (Title I)
OR
Variance from Design Development (Title I)
Approved by Superintendent on
OR
Construction Drawing Not Preceded by Design Development (Title I)
Drawing No.
Date
Project Manager Date
UNITED STATES
TITLE OF DRAWING
DEPARTMENT OF THE INTERIOR
LOCATION WITHIN PARK
NAME OF PARK
REGION COUNTY STATE
DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
CONSTRUCTION DOCUMENTS
NATIONAL PARK SERVICE
DENVER SERVICE CENTER
INDEPENDENCE NATIONAL HISTORICAL PARK
NORTHEAST PHILADELPHIA PENNSYLVANIA
153035
224447
1 13
BASIC DATA: BOUNDARY MAP 123/80,011 5/86; USGS TOPO
MAP 1971; PARK MINI FOLDER; COVER SHEET REVISED &
REDRAWN 1/94. UPDATED 10/98. SGS.
INDEX OF DRAWINGS
SHEET SUB SHEET TITLE OF SHEET
1 CS.1 COVER SHEET
2 CS.2 PROJECT OVERVIEW
3 AS.1 SITE PLAN
4 AD.1 DEMOLITION PLANS AND DEMOLITION DETAIL
5 AD.2 DEMOLITION EXTERIOR ELEVATIONS
6 A1.1 CELLAR & FIRST FLOOR PLANS
7 A1.2 SECOND & THIRD FLOOR PLANS
8 A3.1 EXTERIOR ELEVATIONS
9 A3.2 EXTERIOR ELEVATIONS
10 A8.1 WINDOW SCHEDULE
11 A8.2 WINDOW DETAILS
12 A8.3 WINDOW DETAILS
13 A8.4 TEMPORARY ENCLOSURE & REMOVABLE
SASH DETAILS
NXY
Snapshot
NXY
Text Box
COVER SHEET
NXY
Image
NXY
Text Box 02/28/2020
A/E ARCHITECTURE/ENGINEERING
ABA ARCHITECTURAL BARRIERS ACT
ABAAS ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS
ADA AMERICANS WITH DISABILITIES ACT
ADD ADDITION
ADMIN ADMINISTRATION
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
APPROX APPROXIMATELY
AW AWNING
BLDG BUILDING
BLTS BOLTS
BO BOTTOM OF
C CASEMENT
CL CENTERLINE
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
DH DOUBLE-HUNG
DIA/ø DIAMETER
DWGS DRAWINGS
EL/ELEV ELEVATION
EQ EQUAL
ETR EXISTING TO REMAIN
EX/EXT EXISTING
FCU FAN COIL UNIT
F FIXED
FF FINISHED FLOOR
GL GLASS, GLAZING
GWB GYPSUM WALL BOARD
HABS HISTORIC AMERICAN BUILDING SURVEY
HM HOLLOW METAL
HSR HISTORIC STRUCTURE REPORT
IBC INTERNATIONAL BUILDING CODE
IEBC INTERNATIONAL EXISTING BUILDING CODE
INT INTERIOR
LARPM LIQUID-APPLIED REINFORCED POLYMER MEMBRANE
LG LARGE
MAL MATERIAL
MIN MINIMUM
MAX MAXIMUM
MEP MECHANICAL/ELECTRICAL/PLUMBING
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
NO NUMBER
NPS NATIONAL PARK SERVICE
OC ON CENTER
OH OPPOSITE HAND
OZ OUNCE
PART PARTIAL
PT PRESSURE-TREATED
REF REFRIGERATOR
REQ'D REQUIRED
RM ROOM
SF SQUARE FEET
SH SINGLE-HUNG
SI SQUARE INCH
SIM SIMILAR
SM SMALL
SS STAINLESS STEEL
TECH TECHNICAL
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
USPP UNITED STATES PARK POLICE
VENT VENTILATION
V.I.F. VERIFY IN FIELD
W/ WITH
W/OUT WITHOUT
WD WOOD
KEY TO ABBREVIATIONS
WINDOW TAG
DEMOLITION NOTE
DOOR TAG
DETAIL/ PARTIAL
SECTION
REFERENCE
ELEVATION
REFERENCE
KEY TO SYMBOLS
D.1
X A A1 A
A1
SIM
A1
SIM
X
1i
SECTION
REFERENCE
GENERAL NOTES
1. REFER TO DIVISION 1 AND DIVISION 2 SPECIFICATIONS.
2. COMPLY WITH HAZARDOUS MATERIALS SPECIFICATIONS 02 83 13.
3. COORDINATE EXTENT OF DEMOLITION WITH NEW AND REBUILT WORK.
4. REFER TO SPECIFICAITON SECTIONS 06 03 12 AND 05 52 00 FOR
TREATMENT OF WOOD WINDOW FRAMES, TRIM, SILLS, & SASHES
PLYWOOD
WOOD BLOCKING RIGID INSULATION
FLASHING
KEY TO MATERIALS
SAND, GROUT OR MORTAR FINISH WOOD
DEMOLITION SYMBOLS & NOTES
SCOPE OF WORK
APPLIES TO THE
ITEM SHOWN
WITH DASHED
LINES. SEE
DEMOLITION
DRAWINGS AND
NOTES FOR
EXTENT.
SCOPE OF
WORK APPLIES
TO THE ITEM
SHOWN
IDENTIFIED
EITHER IN THE
NOTE OR AT
THE SYMBOL.
THE FOLLOWING NOTES APPLY TO ALL DEMOLITION WORK WHETHER INDICATED ON THE DEMOLITION DRAWINGS OR REQUIRED
ELSEWHERE IN THE CONTRACT DOCUMENTS.
1.1 GENERAL REQUIREMENTS: THE FOLLOWING GENERAL REQUIREMENTS NOTES APPLY TO ALL DEMOLITION WORK. THE
NOTES ARE NOT SYMBOLICALLY REFERENCED ELSEWHERE IN THE DRAWINGS.
1.2 THE SCOPE OF THE ARCHITECTURAL DEMOLITION FOR THIS PROJECT, APART FROM SPECIFIED UNDER SECTION
"SELECTIVE DEMOLITION," IS SHOWN IN SHEETS NUMBERED AD1.1 AND AD1.2.
1.3 THE DEMOLITION AS INDICATED ON THE DRAWINGS APPLIES TO THE DEFINED SCOPE OF WORK. THE DRAWINGS, IN GENERAL, DO NO SPECIFICALLY ADDRESS DEMOLITION THAT IS DEPENDENT ON THE CONTRACTOR'S INDIVIDUAL "MEANS AND METHODS" OF EXECUTING THE WORK. THE REQUIREMENT FOR THIS DEMOLITION IS UNDER
SPECIFICATION SECTION "SELECTIVE DEMOLTION."
1.4 THE EXTENT OF DEMOLITION SHALL BE COORDINATED WITH THE NEW AND REBUILT WORK.
1.5 "EXTENT OF WORK" SYMBOLS ARE DEFINED AS FOLLOWS:
1.6 THE TERM "REMOVE" IS DEFINED IN THE SPECIFICATION SECTION "SELECTIVE DEMOLITION."
1.7 DURING DEMOLITION, PROVIDE TEMPORARY SUPPORT TO ADJACENT EXISTING CONSTRUCTION AND STRUCTURE TO HOLD
IN PLACE WITHOUT ANY MOVEMENT UNTIL NEW SUPPORTING WORK IS IN PLACE.
D.1
D.1 D.1
SCOPE OF
WORK
APPLIES TO
THE ENTIRE
OPENING FOR
THE ITEM OF
WORK
IDENTIFIED
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
PROJECT OVERVIEW
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
2 13
CS.2
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
NXY
Image
S 3RD ST.
C H E S T N U T
S T
STAGING AREA TO THE SOUTH OF
PROPERTY, COORDINATE FINAL
LOCATION W/ C.O.
HAZARDOUS MATERIAL
TO BE STORED MIN. 50
FT. FROM THE BUILDING
*SEE SPECIFICATIONS
GATE ACCESS AT CHESTNUT ST.
8'-8" CLEAR WIDTH V.I.F.
NO HEIGHT RESTRICTION
GATE ACCESS AT SOUTH 3 ST.
7'-8" CLEAR WIDTH V.I.F.
8'-2" CLEAR HEIGHT V.I.F.
MAINTAIN MIN. 6' CLEAR
GATE ACCESS AT SOUTH 3 ST.
7'-8" CLEAR WIDTH V.I.F.
8'-4" CLEAR HEIGHT V.I.F.
MAINTAIN ACCESS FROM FRONT
DOOR TO SIDEWALK. PROTECT FROM
OVERHEAD CONST.
FULL RAMP ACCESS AND OVERHEAD
PROTECTION MUST BE MAINTAINED
THROUGHOUT CONSTRUCTION
SITE WALL
14'-6" V.I.F.
8'-8" V.I.F.
V.I.F.
10'-9"
V.I.F.
14'-2"
50'-0"
MAINTAIN MIN. 6'-0" CLEAR
TRAVEL PATH THROUGHOUT CONST.
xxxx x xLIGHT POLE
TREE CANOPY
LIGHT POLE
S 3RD ST.
x x x x x x xxxx x x
TREE CANOPY
ROOF LINE ABOVE
1. PROTECT ADJACENT TREE CANOPY
THROUGHOUT CONSTRUCTION.
2. AVOID GRASS AREAS AND PROVIDE
PROTECTION OVER ALL WALKWAYS
THROUGHOUT CONSTRUCTION.
3. PROTECTION BELOW EQUIPMENT TO
BE MADE UP OF A TOP LAYER OF
3/4" EXTERIOR GRADE PLYWOOD, A
MIDDLE LAYER OF 1” RIGID
INSULATION, AND A BOTTOM LAYER
OF 3/4" EXTERIOR GRADE PLYWOOD.
GENERAL SITE NOTES
20 40
SCALE OF FEET
0 20
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
LANDSCAPE:
NAME
CITY, STATE
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :2
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
SITE PLAN
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
3 13
AS.1
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATESXXXXX
XXXXX
SCALE AAS.1
1 SITE PLAN
D.1
D.2
D.3
REMOVE EXTERIOR ROUND TRIM AT
JAMBS FOR REMOVAL OF WINDOW
SASHES
REMOVE PARTING TRIM FROM WINDOW
FRAME
REMOVE WINDOW SASHES FROM
FRAMES FOR RESTORATION
REMOVE INTERIOR WOOD TRIM AND
INT STORM SASHES FOR CLEANING
AND REINSTALLATION
REMOVE WEATHER STRIPPING FROM
FRAMES & WINDOW SASHES
REMOVE PAINT FROM WINDOW
FRAMES, TRIM, & SILLS DOWN TO
BARE WOOD
REMOVE WINDOW ROLLER SHADES
FROM EACH WINDOW, CATALOG,
CLEAN, AND SALVAGE FOR
REINSTALLATION
D.4
D.5
D.6
D.7
D.8
D.9
D.10
D.11
D.12
REMOVE SEALANT AND BACKER ROD
JOINT FILLER MATERIAL FROM WINDOW
FRAME PERIMETERS
REMOVE PAINT TO BARE WOOD; REMOVE
GLAZING PUTTY, GLAZING STOPS, GLASS
FROM EACH SASH; SALVAGE GLASS FOR
REINSTALLATION. WINDOW SASHES TO BE
STRIPPED TO BARE WOOD, READY FOR
RESTORATION.
REMOVE WOOD ROT FROM WINDOW
SASHES; LEAVE SOUND WOOD READY FOR
REPAIRS/REPLACEMENT
REMOVE AND SALVAGE CELLAR AREA WAY
DOORS. PROVIDE SECURE, WEATHER
RESISTANT ENCLOSURE AT AREA WAYS
SIMILAR TO DETAILS 2 & 3 ON A8.4
REMOVE LOOSE PAINT FROM IRON BARS
PREPARE FOR NEW FINISH
5. ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.
014004
006 007
001 017
D.3
TYP
D.7
TYP
VAULT #2
EAST HALL
VAULT #1
VAULT #4
NORTH HALL
MECH. RM.
CENTER HALL
09VAULT #3
SOUTH HALL
VAULT #6
06VAULT #5
D.12
TYP
D.12
TYP
D.3
D.7 D.12
TYP
TYP
TYP
124 123 122 120 119 118
107 108 110 111
D.11 D.11
D.7
D.3
TYP
TYP
EXHIBIT AREA
STORAGE
101A
VESTIBULE
D.3D.7
TYP TYP
224 223 218219220222
206 207 208 210 212211209
D.7
D.3
TYP
TYP
OFFICE
213A
OFFICE
213B
OFFICE
213C
OFFICE
OFFICE
STORAGE
CONF. RM.
OFFICE
MEN'S
WOMEN'S
OFFICE
OFFICE
211A
OFFICE
OFFICE
D.7
D.3
TYP
TYP
306 307 308 310 311 312
D.7
D.3
TYP
TYP
LUNCH ROOM
KITCHEN
MECH. RM.
ACCESSIONS
LIBRARY
STORAGE
CLOSET
302A
STORAGE
303B
STORAGE
303A
STAIR HALL
NORTH HALL
D.7 D.3
TYP
TYP
A8.2
SIM
D.4
D.3
D.5
D.2
D.1
D.6
D.10
INTERIOR
EXTERIOR
D.9
D.8
1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL
WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED
OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON
DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH
WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION
TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.
2. ALL WINDOW WEATHER STRIPPING SHALL BE REMOVED UNLESS NOTED OTHERWISE.
3. SEE DIVISION 02 SPECIFICATIONS FOR ABATEMENT OF ASBESTOS CONTAINING
MATERIALS AND LEAD BASED PAINT.
4. INSTALL TEMPORARY WINDOW PROTECTION (SEE DRAWING A8.4)
GENERAL DEMOLITION NOTES
12 12
SCALE OF INCHES
6 0
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
SCALE B
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
DEMOLITION PLANS AND
DEMOLITION DETAIL
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
4 13
AD.1
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AAD.1
1 CELLAR DEMOLITION PLAN
SCALE AAD.1
2 FIRST FLOOR DEMOLITION PLAN
SCALE AAD.1
3 SECOND FLOOR DEMOLITIONPLAN
SCALE AAD.1
4 THIRD FLOOR PLAN DEMOLITION PLAN
SCALE BAD.1
5 TYP DEMO DETAIL AT JAMB
8 24
SCALE OF FEET
0 8 16
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
224 223 222 221 220 219 218
118119120122123124
TRANSOM WINDOW AND DOOR N.I.C.
014004
BEYONDBEYOND
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
317 316 315 314 313
213214215216217
117 116 115 114
015017
EXT STAIR AND
RAMP BEYOND
CELLAR AREA-WAY DOOREXT IRON BARS IN FRONT
OF CELLAR WINDOWS,
TYP
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
305 304 303 302 301
201202203205 204
104 103 102 101
001003
EXT STAIR AND
RAMP BEYOND
CELLAR AREA-WAY DOOR EXT IRON BARS IN FRONT
OF CELLAR WINDOWS,
TYP
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
311312 310 309 308 307 306
206207208210211212
111 110 108 107
007 006
METAL LOUVERS N.I.C.
TRANSOM WINDOW AND DOOR N.I.C.
EXT STAIR AND RAMP
AT WEST ENTRANCE
BEYOND
BEYOND
EXT IRON BARS IN FRONT
OF CELLAR WINDOWS,
TYP
1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL
WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED
OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON
DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH
WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION
TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.
2. ALL WINDOW WEATHER STRIPPING SHALL BE REMOVED UNLESS NOTED OTHERWISE.
3. SEE DIVISION 02 SPECIFICATIONS FOR ABATEMENT OF ASBESTOS CONTAINING
MATERIALS AND LEAD BASED PAINT.
4. INSTALL TEMPORARY WINDOW PROTECTION (SEE DRAWING A8.4)
GENERAL DEMOLITION NOTES
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
DEMOLITION EXTERIOR
ELEVATIONS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
5 13
AD.2
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AAD.2
2 DEMO EAST ELEVATION
SCALE AAD.2
1 DEMO NORTH ELEVATION
SCALE AAD.2
3 DEMO SOUTH ELEVATION
SCALE AAD.2
4 DEMO WEST ELEVATION
8 24
SCALE OF FEET
0 8 16
A .2 2
A3.2
A .12
004 014
METAL LOUVERS
N.I.C.
VAULT #2
VAULT #1
VAULT #4
VAULT #3
VAULT #5
MECH. RM.
VAULT #6
EAST HALL
CENTER HALL
SOUTH HALL
NORTH HALL
006 007
001 017
IRON BARS IN FRONT
OF CELLAR WINDOWS
TYP
A .2 2
A3.2
A .12
A3.1
A8.3
A8.3
SIM
EXT RAMP AND STAIR
VESTIBULE
EXHIBIT AREA
STORAGE
101A
STAIR HALL
124 123 122 120 119 118
114104
107 108 110 111
EXT PORTICO
ROOF ABOVE
1. PROVIDE NEW BACKER ROD AND SEALANT AT WINDOW FRAME PERIMETERS
2. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW FRAME AND TRIM
WHERE ROT HAS CAUSED DAMAGE
3. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW SASHES.
4. PRIME WOOD SURFACES OF FRAMES AND TRIM
5. PRIME WOOD SURFACES OF WINDOW SASHES PRIOR TO REINSTALLING WINDOW
GLAZING
6. INSTALL GLAZING WITHIN A GLAZING BED, INSTALL GLAZING POINTS, GLASS, AND
GLAZING PUTTY. PRIME GLAZING PUTTY
7. PAINT WINDOW SASHES AND PUTTY – 2 COATS
8. REINSTALL WINDOW SASHES WITHIN FRAME
9. REINSTALL INT STORM WINDOW UNITS AFTER CLEANING AND INSTALL NEW WOOD
TRIM TO MATCH EXISTING. PRIME AND PAINT TO MATCH.
10. SEE DRAWING A8.1 AND SPECIFICATIONS FOR WINDOW SPECIFIC TREATMENT
11. REPLACE ROTTEN WOOD AT CELLAR AREA-WAY DOORS. REMOVE PAINT TO BARE
WOOD. REFURBISH HARDWARE, PRIME AND PAINT (2 COATS) DOORS TO MATCH
EXT. REINSTALL DOORS AND HARDWARE. SEE DRAWING A8.3 DETAILS 2 AND 3
ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.
1. ALL WINDOW SASHES, FRAMES, SILLS, AND TRIM SHALL BE PRIMED AND
PAINTED WITH TWO (2) COATS OF PAINT. WINDOW SASH JAMBS SHALL ONLY
RECEIVE A SINGLE PRIMER COAT OF PAINT. U.N.O.
2. ALL RESTORED WINDOW SASHES SHALL BE REINSTALLED WITHIN THEIR ORIGINAL
LOCATION, WITH ORIGINAL HARDWARE, AND NEW WEATHER STRIPPING UNLESS
NOTED OTHERWISE.
3. REINSTALL ROLLER SHADES IN THEIR ORIGINAL WINDOW LOCATION.
4. INSTALL PARTING TRIM AND ROUND EXTERIOR TRIM FOLLOWING THE
INSTALLATION OF WEATHER STRIPPING AND WINDOW SASHES IN FRAMES.
NEW CONSTRUCTION NOTES
8 0 8 16
SCALE OF FEET
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :0
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
CELLAR & FIRST FLOOR
PLANS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
6 13
A1.1
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA1.1
1 CELLAR PLAN
SCALE AA1.1
2 FIRST FLOOR PLAN
A .2 2
A3.2
A .12
A3.1
OPEN TO BELOW
OFFICE
OFFICE
213A
OFFICE
213B
OFFICE
213C
OFFICE
OFFICE
OFFICE
211A
OFFICE
OFFICE
WOMEN'S
MEN'S
OFFICE
CONF. RM.
STORAGE
ROTUNDA GALLERY
206 207 208 209 210 211 212
218219220221222223224
EXT PORTICO
ROOF ABOVE
A .2 2
A3.2
A .12
A3.1
LIBRARY
ACCESSIONS
MECH. RM.
LUNCH ROOM
STORAGE
303B
STORAGE
303A
KITCHEN
CLOSET
302A
STORAGE
NORTH HALL
STAIR HALL
306 307 308 309 310 311 312
317301
EXT PORTICO
ROOF ABOVE
1. PROVIDE NEW BACKER ROD AND SEALANT AT WINDOW FRAME PERIMETERS
2. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW FRAME AND TRIM
WHERE ROT HAS CAUSED DAMAGE
3. PROVIDE REPLACEMENT WOOD OR DUTCHMAN REPAIR AT WINDOW SASHES.
4. PRIME WOOD SURFACES OF FRAMES AND TRIM
5. PRIME WOOD SURFACES OF WINDOW SASHES PRIOR TO REINSTALLING WINDOW
GLAZING
6. INSTALL GLAZING WITHIN A GLAZING BED, INSTALL GLAZING POINTS, GLASS, AND
GLAZING PUTTY. PRIME GLAZING PUTTY
7. PAINT WINDOW SASHES AND PUTTY – 2 COATS
8. REINSTALL WINDOW SASHES WITHIN FRAME
9. REINSTALL INT STORM WINDOW UNITS AFTER CLEANING AND INSTALL NEW WOOD
TRIM TO MATCH EXISTING. PRIME AND PAINT TO MATCH.
10. SEE DRAWING A8.1 AND SPECIFICATIONS FOR WINDOW SPECIFIC TREATMENT
11. REPLACE ROTTEN WOOD AT CELLAR AREA-WAY DOORS. REMOVE PAINT TO BARE
WOOD. REFURBISH HARDWARE, PRIME AND PAINT (2 COATS) DOORS TO MATCH
EXT. REINSTALL DOORS AND HARDWARE. SEE DRAWING A8.3 DETAILS 2 AND 3
ALL NOTES BELOW APPLY TO ALL WINDOW UNITS U.N.O.
1. ALL WINDOW SASHES, FRAMES, SILLS, AND TRIM SHALL BE PRIMED AND
PAINTED WITH TWO (2) COATS OF PAINT. WINDOW SASH JAMBS SHALL ONLY
RECEIVE A SINGLE PRIMER COAT OF PAINT. U.N.O.
2. ALL RESTORED WINDOW SASHES SHALL BE REINSTALLED WITHIN THEIR ORIGINAL
LOCATION, WITH ORIGINAL HARDWARE, AND NEW WEATHER STRIPPING UNLESS
NOTED OTHERWISE.
3. REINSTALL ROLLER SHADES IN THEIR ORIGINAL WINDOW LOCATION.
4. INSTALL PARTING TRIM AND ROUND EXTERIOR TRIM FOLLOWING THE
INSTALLATION OF WEATHER STRIPPING AND WINDOW SASHES IN FRAMES.
NEW CONSTRUCTION NOTES
8 0 8 16
SCALE OF FEET
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :0
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
SECOND & THIRD FLOOR
PLANS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
7 13
A1.2
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA1.2
1 SECOND FLOOR PLAN
SCALE AA1.2
2 THIRD FLOOR PLAN
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
A8.1
LOCATE WINDOW MOCK
UPS IN OPENINGS
317,217,117, AND 017
EXT STAIR
AND RAMP
BEYOND
CELLAR AREA-WAY DOOR
SEE DETAILS 2 AND 3 ON DWG A8.3
117 116 115 114
217 216 215 214 213
313314315316317
017 015
EXT IRON BARS IN
FRONT OF CELLAR
WINDOWS,
TYP
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
TRANSOM WINDOW AND DOOR N.I.C.
014004
BEYONDBEYOND
124 123 122 120 119 118
224 223 218219220222 221
1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL
WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED
OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON
DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH
WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION
TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.
GENERAL NOTE
8 0 8 16
SCALE OF FEET
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :0
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
EXTERIOR ELEVATIONS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
8 13
A3.1
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA3.1
2 NORTH ELEVATION
SCALE AA3.1
1 EAST ELEVATION
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
EXT STAIR AND
RAMP BEYOND
CELLAR AREA-WAY DOOR
SEE DETAILS 2 AND 3 ON DWG A8.3
101102103104
201202203204205
301302303304305
003 001
EXT IRON BARS IN FRONT
OF CELLAR WINDOWS,
TYP
FIRST FLOOR
0.00'
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
ROOF
45.33'
METAL LOUVERS N.I.C.
A8.1
TRANSOM WINDOW AND DOOR N.I.C.
EXT STAIR AND
RAMP AT WEST
ENTRANCE
BEYOND
BEYOND
107108110111
206207208210212 211
306307308310311312 309
007 006
EXT IRON BARS IN
FRONT OF CELLAR
WINDOWS,
TYP
1. ALL EXTERIOR WOOD WINDOWS ARE IDENTIFIED WITH A WINDOW NUMBER. ALL
WINDOWS, FRAMES, SILLS, TRIM, AND HARDWARE SHALL BE RESTORED UNLESS NOTED
OTHERWISE. EACH WINDOW NUMBER CORRELATES WITH THE WINDOW SCHEDULE ON
DRAWING A8.1. SEE WINDOW SCHEDULE FOR INFORMATION ON TREATMENT FOR EACH
WINDOW. CATALOG EACH WINDOW AND ITS ASSOCIATED HARDWARE WITH ITS LOCATION
TO ENSURE EACH UNIT IS REINSTALLED IN ITS ORIGINAL LOCATION.
GENERAL NOTE
8 0 8 16
SCALE OF FEET
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
EXTERIOR ELEVATIONS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
9 13
A3.2
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA3.2
2 SOUTH ELEVATION
SCALE AA3.2
1 WEST ELEVATION
SECOND FLOOR
19.25'
THIRD FLOOR
33.00'
V.I.F.
4'-4 1/2"
V .I .F
V .I .F
V .I .F
V .I .F
V .I .F
V .I .F
V .I .F
B
A2
A1
D
V.I.F.
4'-11"
V.I.F.
4'-4 1/2"
A8.2
A8.2
A8.3
A8.3
A8.3
A8.3
A8.2
SIM
A8.2
SIM
A8.3
SIM
A8.3
SIM
A8.2
SIM
A8.2
SIM
V.I.F.
4'-4 1/2"
SIM
A8.3
SECOND FLOOR
19.25'
C1C2 C2
V .I .F
12'-2 1/2" V.I.F.
A8.2
SIM
A8.3
SIM
A8.2
SIM
DOUBLE HUNG
V.I.F.
2'-2 1/4"
V.I.F.
5'-6"
V.I.F.
2'-2 1/4"
2 6
SCALE OF FEET
0 2 4
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
WINDOW SCHEDULE
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
10 13
A8.1
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA8.1
WINDOW ELEVATION
TYPES A, B, AND D
WINDOW SCHEDULE
WINDOW
NO.
WINDOW
TYPE
TREATMENT LEVEL AT:
(REFER TO SPECIFICATION SECTION 06 03 12 FOR TREATMENT LEVEL)
COMMENTSWINDOW SASH FRAME & TRIM SILL
001 D 1 2 AT HEAD 1 INTERIOR AND EXTERIOR
003 D 2 NOTE 9
006 D 2 2 2
007 D 2 BOTTOM & SIDE SASH 1 2
008 LV 11 - - - -
009 LV 11 - - - -
015 D 1 1 1
017 D 1 1 1 NOTE 7
101 A1 1 1 1
102 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2
103 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2
104 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2
107 A1 2 SASH MUNTIN 1 1
108 A1 2 FILL SCREW HOLE 1 1 INTERIOR, 2 EXTERIOR
110 A1 2 LOWER SASH MUNTIN & FRAME 1 1
111 A1 2 LOWER SASH 1 1 INTERIOR, 2 EXTERIOR
114 A1 1 3 AT LOWER JAMBS 1 NOTES 2 & 6
115 A1 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
116 A1 1 1 3 NOTE 2
117 A1 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2
118 A1 1 1 2 INTERIOR, 2 EXTERIOR
119 A1 1 1 1 INTERIOR, 2 EXTERIOR
120 A1 1 1 1 INTERIOR, 2 EXTERIOR NOTE 3
122 A1 1 1 1
123 A1 1 1 1 INTERIOR, 2 EXTERIOR
124 A1 2 AT MUNTIN LOWER SASH 1 2 INTERIOR, 2 EXTERIOR NOTE 13 AT LOWER
SASH
201 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
202 A2 1 1 2 INTERIOR AND EXTERIOR
203 A2 2 LOWER SASH 1 2 INTERIOR AND EXTERIOR
204 A2 1 1 2 INTERIOR AND EXTERIOR
205 A2 1 1 3 INTERIOR
206 A2 2 BOTTOM SASH 3 INTERIOR, 2 EXTERIOR
207 A2 1 1 2 INTERIOR AND EXTERIOR
208 A2 2 UPPER SASH MUNTIN 1 1 INTERIOR, 2 EXTERIOR NOTE 4
209 C1 1 2 JAMB CRACK 2 INTERIOR, 3 EXTERIOR NOTE 5
209 A C2 1 1 2 INTERIOR, 2 EXTERIOR NOTE 5
209 B C2 1 2 JAMB CRACK 2 INTERIOR, 2 EXTERIOR NOTE 5
210 A2 2 UPPER SASH MUNTIN 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 3
211 A2 1 1 2 INTERIOR, 2 EXTERIOR
212 A2 1 1 1 INTERIOR, 3 EXTERIOR NOTE 2
213 A2 2 UPPER & BOTTOM SASH 1 2 INTERIOR, 2 EXTERIOR
214 A2 1 1 2 INTERIOR
215 A2 2 SASH MUNTIN AT LOWER SASH 1 1 INTERIOR, 3 EXTERIOR NOTES 2, 3, & 8
216 A2 1 1 3 INTERIOR, 2 EXTERIOR
217 A2 1 1 2 INTERIOR AND EXTERIOR
218 A2 1 1 2 INTERIOR AND EXTERIOR
219 A2 1 1 1 INTERIOR, 2 EXTERIOR NOTE 8
220 A2 1 1 1 INTERIOR, 2 EXTERIOR NOTE 8
221 A2 2 UPPER SASH 1 2 INTERIOR, 2 EXTERIOR
222 A2 1 1 2 INTERIOR, 2 EXTERIOR
223 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
224 A2 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
301 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2, 11, & 12
302 B 1 1 1 INTERIOR AND EXTERIOR NOTES 10 & 11
303 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
304 B 1 1 1 INTERIOR AND EXTERIOR
305 B 2 BOTTOM SASH 3 AT SASH PULLY 2 INTERIOR, 3 EXTERIOR NOTE 2
306 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 14
307 B 1 3 AT HEAD TRIM 2 INTERIOR, 2 EXTERIOR
308 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
309 B 1 1 1 INTERIOR AND EXTERIOR
310 B 1 3 INTERIOR 2 INTERIOR AND EXTERIOR NOTES 1,2, & 12
311 B 1 1 1 INTERIOR, 3 EXTERIOR NOTES 1 & 2
312 B 1 2 AT HEAD TRIM 1 INTERIOR, 3 EXTERIOR NOTES 1 & 2
313 B 1 1 1 INTERIOR AND EXTERIOR NOTE 1
314 B 2 TOP & BOTTOM SASH 1 2 INTERIOR, 3 EXTERIOR NOTES 1 & 2
315 B 1 2 AT HEAD 2 INTERIOR, 3 EXTERIOR NOTE 2
316 B 1 1 2 INTERIOR, 3 EXTERIOR NOTE 2
317 B 1 1 2 INTERIOR, 3 EXTERIOR NOTES 2 & 12
WINDOW NOTES:
1. MODIFY WINDOW SASH TO ACCOMODATE EASY REMOVAL FOR
HVAC EQUIPMENT. SEE DETAILS ON A8.4
2. REMOVE ROTTING SILL AT EXTERIOR, REBUILD SOLID WOOD
SILL, SLOPE AWAY FROM WINDOW
3. REPLACE BROKEN OR MISSING GLASS
4. PATCH DAMAGED SASH FRAME AT LOCKING HARDWARE
5. REINSTALL SASHES WITH UPPER SASH OUTBOARD AND LOWER
SASH TO THE INTERIOR. INSTALL WEATHER STRIPPING TO
ACCOMODATE SASH LOCATION
6. ADJUST JAMB OF INTERIOR STORM SASH TO PREVENT SASH
FROM FALLING, REPLACE SIDE RAILS FOR PROPPER FUNCTION
7. COORDINATE WINDOW RESTORATION WITH EXISTING WIRES
THROUGH WINDOW FRAME AT JAMB
8. PROVIDE BRASS SASH HANDLE TO MATCH EXISTING
9. NOT USED
10. PATCH STONE SILL WHERE WEATHERING HAS CAUSED A
CHANNEL TO PREVENT WATER FROM RUNNING BACK TOWARDS
THE WINDOW SILL
11. PATCH INTERIOR JAMB AT WINDOW WASHER ANCHOR
FASTENER PLUG
12. REPLACE UPPER STORM WINDOW SASH GLAZING AT SECURITY
CAMERA LOCATIONS
13. REPLACE BROKEN STORM GLASS
14. REPLACE SASH WEIGHT CHAIN TO MATCH EXISTING
SCALE AA8.1
2 WINDOW ELEVATION - TYPE C
DOUBLE HUNG
DOUBLE HUNG
DOUBLE HUNG
CASEMENT
WOOD SASH
GLASS
EXT. ARCHITRAVE
EXT. BLOCKING
EXT. STONE LENTIL
FACE N.I.C
SEALANT
BRONZE WEATHER
STRIP
GLAZING PUTTY
REPLACE WOOD
TRIM, MATCH EXT
ALUM. STORM
SASH FRAME
GLAZING PUTTY
GLASS
WOOD SASH
EXT SASH LOCK
REFURBISHED
BRONZE WEATHER
STRIP
GLAZING PUTTY
GLASS
WOOD SASH
PARTING STRIP
INTERIOREXTERIOR
INTERIOREXTERIOR
GLASS
EXT OR NEW WOOD SILL
SLOPED AWAY FROM
GLAZING
BACKER ROD AND SEALANT
WOOD SASH
EXT. WOOD SILL
EXT. STONE SILL
N.I.C.
BRONZE WEATHER STRIP
GLAZING PUTTY
REPLACE WOOD TRIM,
MATCH EXT PROFILE, TYP.
ALUM. STORM SASH FRAME
A8.2
PLASTIC SHIM
ANCHOR NEW WOOD SILLS
TO SUBSTRATE THROUGH
VERTICAL SURFACE
WOOD PLUG FLUSH
W/ FACE OF SILL
EXT WOOD TRIM
PARTING STRIP, BEYOND
EXTERIOR INTERIOR
WOOD MUNTIN
EXT OR NEW GLASS
V .I .F
SETTING BED
GLAZING PUTTY
V.I.F.
INTERIOREXTERIOR
VARIES
WOOD TRIM, PROFILE
TO MATCH EXT
PLUG FASTENER
HEADS, SAND FLUSH
W/ ADJACENT TRIM
FASTENERS 3" FROM
ENDS AND EVERY
18" O.C., TYP
EXTERIOR
VARIES
3/4"
1/2"
V.I.F.
4 1/2"
V .I .F
WOOD FASTENERS
3" FROM ENDS
AND 8" O.C. MAX
WOOD PLUG FLUSH
W/ FACE OF SILL
BACKER ROD AND
SEALANT
PLASTIC SHIM
PARTING STRIP
BEYOND
BRICK MOLD
TRIM BEYOND
EXTERIOR INTERIOR
V .I .F
1/2" VARIES
WOOD
PARTING
STRIP
V.I.F.
WOOD TRIM
TO MATCH
EXT PROFILE
EXTERIOR
INTERIOR
1. SEE SCHEDULE ON A8.1 FOR WINDOWS TO RECEIVE NEW MATERIALS
2. REMOVE ALL HARDWARE, REFURBISH PER SPEC 06 13 12, REINSTALL
GENERAL NOTES
1 0 1 2
SCALE OF FEET
12 12
SCALE OF INCHES
6 0
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
SCALE B
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
WINDOW DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
11 13
A8.2
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA8.2
1 TYP DETAIL AT HEAD AND MEETING RAIL
SCALE AA8.2
4 TYP DETAIL AT SILL
SCALE BA8.2
2 TYP MUNTIN
SCALE BA8.2
5 DETAIL
SCALE BA8.2
3 DETAIL
SCALE BA8.2
6 DETAIL
V .I .F
WOOD SASH
GLASS
GLAZING PUTTY
EXT. WOOD ARCH
BRONZE
WEATHERSTRIPPING
W/ VINYL SEAL
INTERIOREXTERIOR EXT CEM. SILL
WOOD SILL
GLAZING PUTTY
WOOD SASH
GLASS
BRONZE WEATHER STRIP
SEALANT, TYP
BRONZE
WEATHERSTRIPPING
W/ VINYL SEAL
INTERIOR
EXTERIOR
V .I .F
V .I .F
WOOD SASH
GLASS
GLAZING PUTTY
WOOD SILL
PLASTIC SHIM
EXT MASONRY
SILL
V.I.F.
1 1/2"
BACKER ROD
AND SEALANT
BRONZE WEATHER
STRIP
V.I.F.
BRONZE WEATHER
STRIPPING
W/ VINYL SEAL
WOOD SILL STOP
INTERIOR
EXTERIOR
V.I.F.
3'-3 1/2"
V .I .F
V .I .F
V .I .F
E Q
E Q
V .I .F
V .I .F
"REPLACE ROTTEN
WOOD BOARDS ON
DOOR 004
EXT. STONE LINTEL
EXT. BRICK WALL
SEALANT
EXT. STONE TOOLING
V.I.F.
2 1/2"
V.I.F.
8 1/2"V.I.F.
3 1/2"
EXT FASTENERS
IRON STRAP HINGE
EXT FASTENERS
EXT IRON STRAP HINGE
WOOD T&G BOARDS
WIDTH VARIES
ANCHORS
WOOD BLOCKING
SEALANT
RESTORE WOOD CELLAR AREA-WAY
DOORS, REPLACE ROTTING WOOD, STRIP
PAINT TO BARE WOOD, PRIME AND
PAINT - 2 COATS
INTERIOR
EXTERIOR
GLASS
GLAZING PUTTY
WOOD SASH
WEATHER STRIP
V.I.F.
1 3/4"
V.I.F.
2 1/4"
EXTERIOR
GLASS
REINSTALL WOOD SASH
EXT BLOCKING
EXT SPLAYED
WOOD JAMB
PARTING STRIP,
MATCH EXT, GLUE
AND FASTEN W/
FINISH NAILS
PARTING TRIM
BEYOND
EXT. STONE
SILL N.I.C.
GLAZING PUTTY
EXT. LEAD
SASH WEIGHTS
REINSTALLED EXT
WOOD TRIM
REINSTALLED ALUM.
STORM SASH FRAME
A8.2
SIM
BRONZE WEATHER STRIP
EXT. MASONRY
JAMB
EXTERIOR
INTERIOR
SEALANT
1. SEE SCHEDULE ON A8.1 FOR WINDOWS TO RECEIVE NEW MATERIALS
2. REMOVE ALL HARDWARE, REFURBISH PER SPEC 06 13 12, REINSTALL
GENERAL NOTES
8 0 8 16
SCALE OF FEET
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
WINDOW DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
12 13
A8.3 Designer
Author
Checker
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE AA8.3
4 HEAD DETAIL AT CASEMENT WINDOW
SCALE AA8.3
6 JAMB DETAIL AT CASEMENT WINDOW
SCALE AA8.3
5 SILL DETAIL AT CASEMENT WINDOW
SCALE BA8.3
3 CELLAR AREA-WAY DOOR PLAN DETAIL
SCALE BA8.3
2 CELLAR AREA-WAY DOOR SECTION DETAIL
SCALE AA8.3
7 MEETING STILE AT CASEMENT WINDOW
SCALE AA8.3
1 TYP DETAIL AT JAMB
BACKER ROD
PLYWOOD
5/8"
RIGID INSULATION
2"
WOOD FRAMING
2X4
V .I .F
V A R
IE
S
WOOD FRAMING
2x4
BACKER ROD
WOOD FRAMING
WOOD BLOCKING
WOOD BLOCKING
WOOD BLOCKING
EXT WINDOW HEAD
FRAME (SHOWN WITH
SASHES REMOVED)
INTERIOR EXTERIOR
SCAFFOLDING BEYOND
COORD. WITH SCAFOLDING
PT 3/4" PLYWOOD
ENCLOSURE FENCE, PRIMED
AND PAINTED,
C.O. TO SELECT COLOR
SEE SPEC SECTION 01 50 00
2X4 PT WOOD
KICKER, 8' O.C. MAX
50 LBS. SAND BAG
2X4 PT MID-HEIGHT
WOOD FRAMING
3/4" EXT GRADE PLYWOOD
2X4 PT WOOD FRAMING
TYP.
2X PT WOOD BLOCKING
2'-0"
2X4 PT WOOD KICKER
3/4" PT PLYWOOD ON GRADE
50 LBS SAND BAG
2X4 PT WOOD FRAMING
2X PT WOOD BLOCKING4'-0" +/-
V .I .F
V A R
IE
S
EXT WALL
EXT WOOD
CASING TRIM
FELT AT ALL
LOCATIONS
WHERE BLOCKING
IS AGAINST EXT
CONSTRUCTION
2X BLOCKING
BACKER ROD
INTERIOREXTERIOR
WOOD SASH
GLASS
ALUM ANGLE TRIM 1" X
1" X 1/8" FASTENED TO
WINDOW SURROUND, 3
FASTENERS PER SIDE
ALUM. STORM SASH
FRAME W/OUT FASTENERS
GLAZING PUTTY
GLASS
WOOD SASH
EXT SASH LOCK
REFURBISHED
REMOVE PARTING STRIP
AT UPPER SASH, INFILL
W/ WOOD FILL, AND TRIM
FLUSH W/ JAMB AND
HEAD FRAME
GLASS
WOOD SASH
EXT. WOOD SILL
ALUM ANGLE TRIM 1" X 1" X 1/8"
FASTENED TO WINDOW SURROUND,
3 FASTENERS PER SIDE
ALUM. STORM SASH FRAME W/OUT
FASTENERS
REMOVE INT WOOD TRIM, FLUSH
W/ SILL AND JAMB FRAME
PARTING STRIP BEYOND
INTERIOREXTERIOR
INTERIOREXTERIOR
INTERIOREXTERIOR
REMOVE INT WOOD TRIM,
FLUSH W/ SILL AND
JAMB FRAME
HASPE, HANGER
BOLT, AND
BUTTERFLY FASTENER
BEYOND, (4 PER
LOWER SASH)
2 0 2 4
SCALE OF FEET
1 0 1 2
SCALE OF FEET
12 12
SCALE OF INCHES
6 0
A/E FIRM - GWWO
TITLE OF SHEET DRAWING NO.
PMIS/PKG NO.
SHEET
OF
PRIME/ARCH:
GWWO, INC.
BALTIMORE, MD
SUB SHEET NO.DESIGNED:
CADD:
TECH. REVIEW:
DATE:
SCALE A
SCALE B
SCALE C
:4 :1
P M
C A u to d e s k L o c a l F il e s s t B a n k N Y o u n g W A Q .r v t
TEMPORARY ENCLOSURE &
REMOVABLE SASH DETAILS
INDEPENDENCE NATIONAL HISTORICAL PARK
153035
224447
13 13
A8.4
BCW
NY
MLP
02/28/2020
FIRST BANK OF THE UNITED STATES
SCALE BA8.4
2 TYP. TEMPORARY WINDOW ENCLOSURE SECTION
SCALE BA8.4
3 TYP. TEMPORARY WINDOW ENCLOSURE PLAN
SCALE C
A8.4
SITE FENCE PLAN
SCALE C
A8.4
SITE FENCE SECTION
SCALE AA8.4
HEAD, MEETING RAIL, SILL DETAIL
AT REMOVABLE WINDOW TYPE C
| Sheets |
| CS.1 - COVER SHEET |
| CS.2 - PROJECT OVERVIEW |
| AS.1 - SITE PLAN |
| AD.1 - DEMOLITION PLANS AND DEMOLITION DETAIL |
| AD.2 - DEMOLITION EXTERIOR ELEVATIONS |
| A1.1 - CELLAR & FIRST FLOOR PLANS |
| A1.2 - SECOND & THIRD FLOOR PLANS |
| A3.1 - EXTERIOR ELEVATIONS |
| A3.2 - EXTERIOR ELEVATIONS |
| A8.1 - WINDOW SCHEDULE |
| A8.2 - WINDOW DETAILS |
| A8.3 - WINDOW DETAILS |
| A8.4 - TEMPORARY ENCLOSURE & REMOVABLE SASH DETAILS |
File details come from the government source that posted it. Updated .