WORLAND_FIELD_OFFICE_BID_SET_08_24_21_0001.pdf
PDF 2 MB Posted
- Attached to
- BLM WYOMING WORLAND AND CODY SECURITY SYSTEMS Federal contract opportunity
- Solicitation number
- 140L6221R0039
About this file
This set of bid documents outlines requirements for a security systems project at two Bureau of Land Management field offices in Wyoming. The solicitation seeks installation of access control, intrusion detection, video surveillance, and duress systems at BLM's Worland and Cody offices. Drawings and specifications are provided for access control panels, card readers, electric locks, interior and exterior cameras, fiber infrastructure, a centralized monitoring platform, and integration with the sites' existing systems. Bidders are to provide all labor, materials, equipment, and supervision for a fully functioning security solution. The response deadline is August 24, 2021, with work to commence upon award of contract number 140L6221R0039.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 140L6221R0039_AMD_0004_QUESTIONS_AND_ANSWERS_Final_0004.docx | DOCX document | |
| Sol_140L6221R0039_Amd_0004.pdf | ||
| 140L6221R0039_AMD_0003_CODY_FIELD_OFFICE_BID_SET_08_24_21_0003.pdf | ||
| Sol_140L6221R0039_Amd_0003.pdf | ||
| 140L6221R0039_AMD_0002_QUESTONS_AND_ANSWERS_0002.docx | DOCX document | |
| Sol_140L6221R0039_Amd_0002.pdf | ||
| CODY_FIELD_OFFICE_BID_SET_08_24_21_0001.pdf | ||
| Sol_140L6221R0039_Amd_0001.pdf | ||
| CertificationVaccinationPRAv7_Contractors_0001.pdf | ||
| Vaccination_Certification_Notification_to_DOI_Contractors_0001.pdf | ||
| Cody_Field_Office_Security_System_Installation_Bid_Schedule.xlsx | XLSX spreadsheet | |
| Sol_140L6221R0039.pdf | ||
| Worland_Field_Office_Security_System_Installation_Bid_Schedule.xlsx | XLSX spreadsheet | |
| BLM_Wyoming_Worland_and_Cody_Field_Office_Security_System_Installation_SOW.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUREAU OF LAND MANAGEMENT
WORLAND FIELD OFFICE
101 S 23RD ST.
WORLAND, WY 82401
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
BLM-WFO-01-101
01-101
SECTION - GENERAL
COVER SHEET
WORLAND FIELD OFFICE
© 2017 GOOGLE © 2017 GOOGLE © 2017 GOOGLE
B
I
D
S
E
T
O
N
L
Y
XX
XX
XX
GENERAL SYMBOLS
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
SECTION NUMBER
DETAIL NUMBER
DETAIL DESCRIPTION
ADDITIONAL DETAIL INFORMATION
SHEET NUMBER
AREA OF INCLUSION
00-000
2c 18 AWG
NUMBER OF CONDUCTORS
GAUGE OF WIRE
FILE NUMBER DESIGNATION
XXX-XXX-XX-XXX
FACILITY DESIGNATOR
LOCATION DISCIPLINE DESIGNATOR
DRAWING TYPE DESIGNATOR
3-4 DIGIT SEQUENTIAL PAGE NUMBER
0 - GENERAL (SYMBOLS LEGEND, NOTES, ETC.)
01 COVER SHEET
02 SYMBOLS PAGE
03 ABBREVIATIONS
04 DRAWING INDEX
05 EQUIPMENT LISTS
1 - PLANS (HORIZONTAL VIEWS)
10 - PLAN VIEWS
A. OVERALL PLAN VIEWS
B. SPECIFIC BUILDING PLAN VIEWS
C. ENLARGED PLAN VIEWS
11 - ELECTRICAL & CABLING
A. PLAN VIEWS SHOWING ELECTRICAL CONDUIT RUNS
B. PLAN VIEWS SHOWING FIBER OPTIC CONDUIT RUNS
C. JUNCTION BOX LOCATIONS
D. WIRE DETAILS OF SIZE, QUANTITY
2 - ELEVATIONS (VERTICAL VIEWS)
3 - SECTIONS (SECTIONAL VIEWS)
4 - LARGE-SCALE VIEWS
(PLANS, ELEVATIONS OR SECTIONS THAT ARE NOT DETAILS)
5 - DETAILS
6 - SCHEDULES AND DIAGRAMS
60 - BLOCK DIAGRAMS
61 - ONE-LINE DIAGRAMS
62 - EQUIPMENT INTERCONNECTION DIAGRAMS
63 - WIRING DIAGRAMS NOT SPECIFIC TO EQUIPMENT
64 - TELECOMMUNICATIONS DIAGRAMS
65 - EQUIPMENT SCHEDULES
66 - PROGRAMMING SCHEDULES
67 - RACEWAY/CIRCUIT SCHEDULES
DRAWING TYPE DESIGNATOR
(PER ERDC/ITL TR-06-X; TABLE 2-3)
NOTE: PAGE NUMBER IS AN ABBREVIATED VERSION OF THE FILE NUMBER
WIRE GAUGE DESIGNATION
XX-XXX
XX-XXX
XX-XXX
1. GENERAL NOTES ON THIS SHEET APPLY TO ALL DRAWINGS.
2. LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THE SET OF DRAWINGS. ADDITIONAL LEGENDS AND/OR OTHER LEGEND SHEETS MAY
APPEAR ON SPECIFIC DRAWINGS TO INDICATE SPECIFIC CONDITIONS.
3. NEWLY INSTALLED ENCLOSURES, CABINETS, HOUSINGS, BOXES AND FITTINGS HAVING HINGED
DOORS OR REMOVABLE COVERS AND WHICH CONTAIN CIRCUITS OR CONNECTIONS OF THE
ACS SYSTEM AND ITS POWER SUPPLIES, SHALL BE PROVIDED WITH COVER OPERATED,
CORROSION RESISTANT TAMPER SWITCHES, ARRANGED TO INITIATE AN ALARM SIGNAL
WHEN THE DOOR OR COVER IS MOVED. THE ENCLOSURE AND THE TAMPER SWITCH SHALL
FUNCTION TOGETHER AND SHALL NOT ALLOW DIRECT LINE OF SIGHT TO ANY INTERNAL
COMPONENTS BEFORE THE SWITCH ACTIVATES. TAMPER SWITCHES SHALL BE
INACCESSIBLE UNTIL THE SWITCH IS ACTIVATED; HAVE MOUNTING HARDWARE
CONCEALED SO THAT THE LOCATION OF THE SWITCH CANNOT BE OBSERVED FROM THE
EXTERIOR OF THE ENCLOSURE; BE CONNECTED TO CIRCUITS WHICH ARE UNDER
ELECTRICAL SUPERVISION AT ALL TIMES, IRRESPECTIVE OF THE PROTECTION MODE IN
WHICH THE CIRCUIT IS OPERATING; SHALL BE SPRING-LOADED AND HELD IN THE
CLOSED POSITION BY THE DOOR OR COVER; AND SHALL BE WIRED SO THAT THE
CIRCUIT IS BROKEN WHEN THE DOOR OR COVER IS DISTURBED.
4. ACCESS CONTROL SYSTEM EQUIPMENT MUST BE EQUIPPED WITH CONTINUOUSLY MONITORED
TAMPER DETECTION DEVICES REGARDLESS OF WHETHER THE SYSTEM IS IN THE ACCESS OR
SECURE MODE OF OPERATION. UPON DETECTION, AN ALARM (NOT FAULT) CONDITION MUST BE
TRANSMITTED TO THE PCU OR MONITORING STATION.
5. EXACT MOUNTING LOCATION OF ACS, DAS, CCTV SHALL BE VERIFIED PRIOR TO INSTALLATION.
6. ALL EXTERIOR HOUSING ENCLOSURE BOXES SHALL BE NEMA 4X RATED.
7. CONTRACTOR SHALL INSTALL A WARNING UNDERGROUND MARKER TAPE ABOVE ALL SECURITY
UNDERGROUND DUCTBANKS. IT SHALL BE SOLID FOIL MARKER TAPE, ORANGE, 3 INCHES WIDE, DETECTABLE, NON-DEGRADABLE, CORROSION RESISTANT, TEAR RESISTANT AND WITH
1 1/4 INCH STENCILED BLACK NON-DEGRADABLE LETTERS. WORDING ON MARKERS READ
"CAUTION DUCTBANK BURIED BELOW." TRACER WIRE SHALL BE INCLUDED WITH ALL DIRECTIONAL BORING.
8. ALL FIELD DISTRIBUTION BOXES AND SECURITY EQUIPMENT CABINETS SHALL HAVE A GROUNDING
LUG OR A GROUNDING BUS BAR INSTALLED.
9. ALL COPPER WIRE TERMINATIONS SHALL HAVE AT LEAST A 3'-0" (0.91m) SERVICE
LOOP AT EACH END. ALL ESS WIRING SHALL HAVE AT LEAST 3'-0" BETWEEN A SURGE
PROTECTOR AND A DEVICE.
10. IF ANY REQUIRED INFORMATION IS NOT CONTAINED WITHIN THIS SET OF DRAWINGS, REFER TO
MANUFACTURER SUPPLIED INSTRUCTIONS.
11. THESE DRAWINGS ARE DIAGRAMITC IN NATURE AND ARE NOT INTENDED TO SHOW EXACT CONDITIONS
AS MAY EXIST UNLESS NOTED OTHERWISE.
12. DO NOT SCALE DRAWINGS AS PROVIDED SCALES ARE FOR REFERENCE ONLY.
13. THE SCALES APPLIED TO THE DRAWINGS ARE BASED OFF U.S. CUSTOMARY UNITS STANDARD.
GENERAL NOTES
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
GENERAL INFORMATION
BLM-WFO-01-102
01-102
SECTION - GENERAL
WORLAND FIELD OFFICE
B
MCL
NOTE: ABBREVIATIONS LISTED ARE BASED ON INDUSTRY STANDARDS AND ALL MAY NOT BE APPLICABLE TO PROJECT.
ABBREVIATIONS SECURITY LEGEND
ALARM INTERFACE
CENTRAL PROCESSING UNIT
ELECTRONIC ENTRY CONTROL SYSTEM
HAND GEOMETRY UNIT
INTRUSION DETECTION SYSTEM
ACC/SEC
BMS
CJB
CPU
CR
ECE
EECS
HGU
IDS
DCM DOOR CONTROL MODULE
CARD READER
CU COPPER
EMT ELECTRICAL METALLIC TUBING
BALANCED MAGNETIC SWITCH
ENROLLMENT CENTER EQUIPMENT
H
DC DIRECT CURRENT
CTL CONTROL
AMP
ABOVE FINISHED FLOOR
AMPERE
EP EXPLOSION PROOF
AIF ACTIVE INFRARED SENSOR
DIB DEVICE INTERFACE BOX
CLOSED CIRCUIT TELEVISIONCCTV
CAMERA JUNCTION BOX
CTW CAMERA TOWER
DB
AFF
DP DISTRIBUTION POWER
AWG AMERICAN WIRE GAUGE
AUX
APPROX APPROXIMATELY
AUXILIARY
ADMIN ADMINISTRATOR
BLDG BUILDING
CAB
C
CABINET
COMM COMMUNICATION
DIST DISTANCE
ELECT ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
ENCL ENCLOSURE
UNDERGROUND DUCTBANK
EHH ELECTRICAL HAND HOLE
HIGH
BAT BATTERY
BC BATTERY CHARGER
DVR DIGITAL VIDEO RECORDER
EMI ELECTROMAGNETIC INTERFERENCE
EMH
ELECTRICAL MANHOLE
CONDUIT
ERAC
BPS BYPASS SWITCH PANEL
ELEVATIONEL
FOP FIBER OPTIC DISTRIBUTION PANEL
FORX
FOT
FIBER OPTIC RECEIVER MODULE
FIBER OPTIC TRANSMISSION PANEL
GND GROUND
FDB FIELD DISTRIBUTION BOX
GALV GALVANIZED
GB GLASS BREAK
FOSC FIBER OPTIC SENSOR CABLE
(F) FUTURE
FO FIBER OPTIC
FOCC FIBER OPTIC I/O CONVERTER
GS GATE SENSOR SWITCH
GSB GATE SENSOR SWITCH JUNCTION BOX
FOB FIBER OPTIC BOX
FOSS FIBER OPTIC SENSOR SYSTEM
EXT EXTERIOR
EQUIPMENT RACK AIR CONDITIONER
FFOM FENCE FIBER OPTIC MODULE
FFOR FENCE FIBER OPTIC RACK
FOM FIBER OPTIC MODULE
FOPP FIBER OPTIC PATCH PANEL
FOR FIBER OPTIC RACK
I/O INPUT/OUTPUT
RIGID GALVANIZED STEEL
STAINLESS STEEL
RGS
SST
UPS
VM
REX
TSL TURNSTILE
SSC
TA
TAS
TROUBLE ALARM
T
TBD TO BE DETERMINED
REQ'D REQUIRED
SW SWITCH
TB TERMINAL BLOCK
W
VIDEO MONITOR
UNINTERRUPTIBLE POWER SUPPLY
TAMPER ALARM SWITCH
REQUEST TO EXIT DEVICE
V VOLTAGE
ST STRAIGHT TIP
SP SPARE
QTY QUANTITY
PR PAIR
WIDTH
PWS POWER SUPPLY ENCLOSURE
SSB SURGE SUPPRESSION BOX
TWF TAUT WIRE FENCE ALARM AREA
PP POWER PANEL
TRANSFORMER/TAMPER
UL
UNDERWRITERS LABORATORIES
TYP TYPICAL
WHT WHITE
W/ WITH
OH OVERHEAD
REC RECEIVING
SO FLEXIBLE POWER CORD
SQ SQUARE
SHH SECURITY HAND HOLE
VLS VEHICLE LOOP SENSOR
TV TELEVISION
THHN 90°, 600 VOLT NYLON JACKETED
BUILDING WIRE FOR DRY LOCATIONS
SS
SCMS SITE CONTROL AND MONITORING
SYSTEM
PNL PANEL
PTZ PAN TILT AND ZOOM
PVC POLYVINYL CHLORIDE
GATE SAFETY SENSOR
SURGE SUPPRESSOR-COAX
SSDA SURGE SUPPRESSOR-DATA
SSP SURGE SUPPRESSOR-POWER
SPDT SINGLE POLE DOUBLE THROW
SWGR SWITCHGEAR
WS WORK STATION
OSSC
PS POWER SUPPLY
SCH SCMS HUB
SCP
SCW
SCWC
SCMS PRINTER
SCMS WORKSTATION
SCMS WORKSTATION CONSOLE
LP
LOPA LOSS OF POWER ALARM
NTS NOT TO SCALE
NO
NC NORMALLY CLOSED
NORMALLY OPEN
lbs POUNDS
LED LIGHT EMITTING DIODE
LAN LOCAL AREA NETWORK
MSR MAIN SERVICE ROAD
NO. NUMBER
NOT IN CONTRACTNIC
KBD
KPD
CCTV KEYBOARD
KEYPAD
JUNCTION BOXJB
MLIB
MON
MATRIX LOOPING INPUT BAY
MECH MECHANICAL
MONITOR
CCTV ALARM INTERFACE UNITTVAI
CCTV CENTRAL PROCESSING UNITTVCP
LANU LOCAL AREA NETWORK UNIT
TP TELEPHONE DISTRIBUTION PANEL
LSI LEAD SYSTEM INTEGRATOR
SPP SECURITY POWER PANEL
VID VIDEO
LOCAL PROCESSOR
ON-SITE SUPPORT CENTER
SJB SECURITY JUNCTION BOX
HS HATCH SWITCH
HVR HIGH VOLTAGE RELAY
LCD LIQUID CRYSTAL DISPLAY
RECP RECEPTACLE
RTC REMOTE TERMINAL CONTROLLER
AS ALARM SOUNDER
ECU ELECTRIC CYLINDER UNLATCH
A:
B:
C:
D:
E:
F:
G:
H:
I:
J:
K:
L:
MBS MATRIX BAY SWITCH
M:
N:
O:
P:
Q:
R:
S:
T:
U:
V:
W:
TIC TELEPHONE INTERCOM
VAC VOLTAGE ALTERNATING CURRENT
VDC VOLTAGE DIRECT CURRENT
ITS INFRASTRUCTURE TAMPER SWITCH
ES ELECTRIC STRIKE
BMX BISTATIC MICROWAVE TRANSMITTER
BMR BISTATIC MICROWAVE RECEIVER
MS MAGNETIC SWITCH
SDR SECURITY DOOR/GATE
CAM CAMERA
OPR GATE OPERATOR
DT DUAL TECHNOLOGY MOTION SENSOR
DS DURESS SWITCH
HEAT DETECTORHD
PREX PUSH-ACTIVATED REQUEST TO EXIT
STR STROBE
HORNHRN
PB PUSH BUTTON
MAG ELECTROMAGNETIC LOCK
HWS HORN WITH STROBE
MIC MICROPHONE
FAK FIRE ALARM KEYPAD
SD SMOKE DETECTOR
PIR PASSIVE INFRARED
MM MONOSTATIC MICROWAVE
SM SINGLE MODE FIBER OPTIC
SEC SECURITY EQUIPMENT CABINET
WAP WIRELESS ACCESS POINT
CPL CAMERA POLE
CAS FIBER OPTIC CASSETTE
EX EXISTING
WDS WIRELESS DURESS SWITCH
AN ANNUNCIATOR
DPS DOOR POSITION SWITCH
ACCESS CONTROL MODULEACM
IR INFRARED
HPB HANDICAP PUSH BUTTON
INTERCOMINT
DAS DURESS ALARM SYSTEM
DPDT DOUBLE POLE DOUBLE THROW
ECB ELECTRIC CRASH BAR
EML ELECTRIC MORTISE LOCK
FOPC FIBER OPTIC PATCH CASSETTE
FIELD OF VIEW
FOTC
FOTX
FOV
FIBER OPTIC TRANSCEIVER MODULE
FIBER OPTIC TRANSMITTER MODULE
FEETFT
F CONTINUED:
GCM GENERAL CONTROL MODULE
INTERCOM MASTERINT/M
INTERMEDIATE METALLIC CONDUIT IMC
NVR NETWORK VIDEO RECORDER
SPST SINGLE POLE SINGLE THROW
FJB FIBER OPTIC JUNCTION BOX
HH HAND HOLE
MCB MECHANICAL CRASH BAR
MCL MECHANICAL CIPHER LOCK
PUSH BUTTON
CARD READER
CONTACTLESS CARD READER W/ KEYPAD
REQUEST TO EXIT
INTERCOM
ELECTRIC STRIKE
ELECTROMAGNETIC LOCK
ACCESS CONTROL PANEL
DURESS SYSTEM
EQUIPMENT GROUND
STROBE
POLE
NORTH ARROWS
UNINTERRUPTABLE POWER SUPPLY
ACS
FIXED CAMERA
DIGITAL 180° FIXED CAMERA
DIGITAL 270° FIXED CAMERA
WIRELESS ACCESS POINT
CCTV
IDS
ALARM KEYPAD
(ALARM INTERFACE)
DOOR POSITION SWITCH
WIDE GAP
DURESS SWITCH
CHAIN LINK FENCE
GENERAL SYMBOLS
DOOR POSITION SWITCH
ELECTRICALLY OPERATED CRASH BAR
REFERENCED NOTE
DETAIL REFERENCE
XX-XXX
UPS
ECB
MAG
K
N
BALANCED MAGNETIC SWITCH
UL LEVEL 2, HIGH SECURITYHS
BALANCED MAGNETIC SWITCH
ES
CONTACT/CONTACTLESS CARD READER W/ KEYPAD
K
C/CL
MECHANICAL CIPHER LOCK
W
180 DEGREE
270 DEGREE
D
360° FISH EYE CAMERA
ACP
DURESS
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
ABBREVIATIONS &
SECURITY LEGENDS
BLM-WFO-01-103
01-103
SECTION - GENERAL
WORLAND FIELD OFFICE
B
DRAWING INDEXDRAWING INDEXDRAWING INDEX
GENERAL SHEET #
BLM-WFO-01-101 COVER SHEET 01 OF 18
BLM-WFO-01-102 GENERAL INFORMATION 02 OF 18
BLM-WFO-01-103 ABBREVIATIONS AND SECURITY LEGENDS 03 OF 18
BLM-WFO-01-104 DRAWING INDEX 04 OF 18
BLM-WFO-01-105 EQUIPMENT LIST 05 OF 18
PLANS SHEET #
BLM-WFO-10-001 WORLAND FIELD OFFICE SITE REFERENCE PLAN 06 OF 18
BLM-WFO-10-002 WORLAND FIELD OFFICE SITE REFERENCE PLAN WITH CCTV FOV(S) 07 OF 18
BLM-WFO-10-003 WORLAND FIELD OFFICE GATE PLANS WITH DEVICES 08 OF 18
BLM-WFO-10-101 WORLAND FIELD OFFICE 1ST FLOOR REFERENCE PLAN 09 OF 18
BLM-WFO-10-102 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS 10 OF 18
BLM-WFO-10-103 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS CONTINUED 11 OF 18
BLM-WFO-10-104 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS CONTINUED 12 OF 18
BLM-WFO-10-105 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS CONTINUED 13 OF 18
BLM-WFO-10-106 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS CONTINUED 14 OF 18
BLM-WFO-10-107 WORLAND FIELD OFFICE 1ST FLOOR ENLARGED FLOOR PLAN WITH CCTV FOV(S) AND DEVICE LOCATIONS CONTINUED 15 OF 18
BLM-WFO-10-108 WORLAND FIELD OFFICE 2ND FLOOR REFERENCE PLAN AND STROBE LOCATIONS 16 OF 18
BLM-WFO-10-109 WORLAND FIELD OFFICE 2ND FLOOR ENLARGED PLAN SHOWING SECURITY EQUIPMENT AND CCTV FOV(S) 17 OF 18
BLM-WFO-10-201 WORLAND FIELD OFFICE SHOP BUILDING FLOOR PLAN SHOWING EXISTING DEVICES AND CCTV FOV(S) 18 OF 18
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
DRAWING INDEX
BLM-WFO-01-104
01-104
SECTION - GENERAL
WORLAND FIELD OFFICE
B
EQUIPMENT LIST
NOTE: EQUIPMENT LISTED REPRESENTS PRIMARY COMPONENTS ONLY AND IS NOT AN ALL INCLUSIVE LIST FOR A FULLY FUNCTIONING SYSTEM.
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
EQUIPMENT LIST
BLM-WFO-01-105
01-105
SECTION - GENERAL
WORLAND FIELD OFFICE
B
X
X
X
P A
R K
I N
G
S I D
E W
A L
K
SIDEWALK
S I D
E W
A L
K
S I D
E W
A L
K
S
R
D
S
T
BIG HORN AVE.
SHOP
S E
C U
R E
D
P
A R
K I N
G
P A
R K
I N
G
EXISTING FENCE
S I D
E W
A L
K
S I D
E W
A L
K
WORLAND OFFICE
A1
10-101
FLOOR PLAN
A1
10-201
10-003
NORTH GATE PLAN
A4
SOUTH GATE
PLAN
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-001
10-001
SECTION - PLANS
WORLAND FIELD OFFICE
SITE REFERENCE PLAN
SITE REFERENCE PLAN
A1
N
WORLAND FIELD OFFICE
SCALE: 1" = 60'
0'-0" 60'-0"
B
X
X
SIDEWALK
BIG HORN AVE.
EXISTING FENCE
A1
10-101
10-201
NORTH GATE PLAN
A4
SOUTH GATE
PLAN
P A
R K
I N
G
S I D
E W
A L
K
S I D
E W
A L
K
S I D
E W
A L
K
S
R
D
S
T
SHOP
S E
C U
R E
D
P
A R
K I N
G
P A
R K
I N
G
S I D
E W
A L
K
S I D
E W
A L
K
WORLAND OFFICE
270 DEGREE
180 DEGREE
270 DEGREE
270 DEGREE 270 DEGREE
180 DEGREE
180 DEGREE
180 DEGREE
CONTRACTOR TO INSTALL NEW TRENCH TO EXISTING
POLES FOR NEW CAMERAS. INSTALL A NEW 1"
UNDERGROUND CONDUIT TO THE EXISTING POLES
AND NEW CAMERAS. COVER TRENCH AND RE-ASPHALT.
SEE DWG 10-201
INSTALL NEW 180 DEGREE CAMERA ON
EXISTING LIGHT POLE. SEE DWG 10-201
INSTALL NEW 180 DEGREE CAMERA ON
EXISTING LIGHT POLE. SEE DWG 10-201
INSTALL A NEW 5MP FIXED CAMERA ON
EXISTING LIGHT POLE. SEE DWG 10-201
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-002
10-002
SECTION - PLANS
WORLAND FIELD OFFICE
SITE REFERENCE PLAN
WITH CCTV FOV(S)
N
WORLAND FIELD OFFICE
SCALE: 1" = 60'
0'-0" 60'-0"
SITE PLAN W/ CCTV FOV(S)
A1
B
X
X
X
X
X
X
X
X
X
X
X
X
SHOP
X
EXISTING STANCHION
EXISTING SECURITY GATE CONTROLLER
S
E
C
U
R
D
E
U
N
S
E
C
U
R
D
E
EXISTING SECURITY GATE
EXISTING PEDESTRIAN GATE
W
A
C
P
ES
2 4 5
CR-116
CR-117
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
EXISTING STANCHION
EXISTING SECURITY GATE CONTROLLER
SECURED SIDE
UN-SECURED SIDE
EXISTING SECURITY GATE
A C
P
CR-118
ES
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-003
10-003
SECTION - PLANS
WORLAND FIELD OFFICE
GATE PLANS WITH
DEVICES
N
NORTH GATE SITE PLAN
A1
0'-0" 8'-0"
SCALE: 1/8" = 1'
N
0'-0" 8'-0"
SCALE: 1/8" = 1'
COMPONENT WIRING DETAILSSYMBOL
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
NOTES:
EXISTING CARD READER TO BE
REPLACED WITH NEW.
INSTALL NEW ACCESS CONTROL PANEL.
EXACT MOUNTING LOCATIONS OF ACCESS
CONTROL PANEL SHALL BE VERIFIED BY
ONSITE REPRESENTATIVE PRIOR TO
INSTALLATION.
INSTALL NEW DOOR POSITION SWITCH
WIDE GAP.
INSTALL NEW ELECTRIC STRIKE.
K
CARD READER W/ KEYPAD
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
SEE DETAIL
ACCESS CONTROL PANEL
ACP
A1/53-102
A1/53-105
EQUIPMENT REFERENCE CHART
COMPONENT WIRING DETAILSSYMBOL
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
K
CARD READER W/ KEYPAD
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
EQUIPMENT REFERENCE CHART
SOUTH GATE SITE PLAN
A4
DOOR POSITION SWITCH
WIDE GAP
W
A4/53-107
ELECTRIC STRIKE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
SEE DETAIL
ACP
A1/53-102
NOTES:
EXISTING CARD READER TO BE
REPLACED WITH NEW.
INSTALL NEW ACCESS CONTROL PANEL.
EXACT MOUNTING LOCATIONS OF ACCESS
CONTROL PANEL SHALL BE VERIFIED BY
ONSITE REPRESENTATIVE PRIOR TO
INSTALLATION.
CUSTOMER MAY HAVE A SPARE CONDUIT
FOR COMMUNICATIONS INSTALLED. IF
THERE IS NOT A SPARE CONDUIT THEN
THE ACCESS CONTROL PANEL WILL BE
STAND-ALONE.
ACCESS CONTROL PANEL
A4/53-108
B
10-10210-107 10-10410-105
10-102 10-103
10-104
10-105
10-10610-107
10-10310-106
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-101
10-101
SECTION - PLANS
WORLAND FIELD OFFICE
1ST FLOOR REFERENCE
PLAN
N
WORLAND FIELD OFFICE
0'-0" 16'-0"
SCALE: 1/16"=1'
WORLAND FIELD OFFICE
A1
B
OFFICE AREA
OFFICE
10-107
FIELD
MANAGER
S
S
S
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-102
10-102
SECTION - PLANS
WORLAND FIELD OFFICE
A1
WORLAND FIELD OFFICE
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
NOTES:
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
INSTALL WORKSTATION FOR MONITORING THE CCTV SYSTEM. EXACT
MOUNTING LOCATION TO BE VERIFIED BY ONSITE REPRESENTATIVE.
NN
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
EQUIPMENT REFERENCE CHART
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/52-104
SYMBOLCOMPONENT
CLIENT WORKSTATION
WITH MONITOR
D1/51-105
D4/54-103
B
F
F I C
E
A
R E
A
TEL.
O F
F I C
E
FM OFFICE
BREAK ROOM
RANGER
M A
N A
G E
R
CONFERENCE
VESTIBULE
K
MAG
ECB
K
ES
ECB
MAG
10-106
C O
R R
I D
O R
DOOR-101
4 5
RANGER DOOR
DOOR-110
DOOR-108
CAM-101
DOOR-109
K
K
S
S
S
S
S
S
PRINTER
ROOM
WOMEN'S
LOCKER ROOM
MEN'S
LOCKER ROOM
ES
K
180 DEGREE
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-103
10-103
SECTION - PLANS
WORLAND FIELD OFFICE
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
CONTINUED
WORLAND FIELD OFFICE
A1
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
K
CARD READER W/ KEYPAD
REQUEST TO EXIT
DOOR POSITION SWITCH
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
A1/53-108
ES
EXISTING
RE-USE ELECTRIC STRIKE
COMPONENT
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
NOTES:
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS
EXISTING CARD READER TO BE REPLACED WITH NEW. RE-USE ALL OTHER EXISTING ACCESS
CONTROL EQUIPMENT.
ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH
PROTECTOR AND SECURITY HINGES.
INSTALL NEW EXTERIOR 180 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND
INTEGRATE INTO THE NEW CCTV SYSTEM.
REMOVE EXISTING CIPHER LOCK AND INSTALL NEW CARD READER, REX, BMS, AND
ELECTRIC STRIKE.
EXISTING - SEE NOTE 2 BELOW
EXISTING
RE-USE MAG LOCK
EXISTING - SEE NOTE 2 BELOW
MAG
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
EXISTING
RE-USE ELECTRIC CRASHBAR
EXISTING - SEE NOTE 2 BELOW
ECB
A1/53-107
NN
A4/52-104
CAT6 PLENUM A1/51-101
180 DEGREE CAMERA
180 DEGREE
B
WAREHOUSE
STORAGE
WAREHOUSE
FIRE CACHE
C O
R R
I D
O R
C O
R R
I D
O R
10-105
K
E C
B
M A
G
DOOR-102
2 3
CAM-102
S
S
S
S
S
EXCERCISE
ROOM
CAM-108
270 DEGREE
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-104
10-104
SECTION - PLANS
WORLAND FIELD OFFICE
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
CONTINUED
WORLAND FIELD OFFICE
A1
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
K
FIXED INTERIOR 1MP CAMERA
CARD READER W/ KEYPAD
REQUEST TO EXIT
DOOR POSITION SWITCH
CAT6 PLENUM
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
A1/51-103
A1/53-108
COMPONENT
NOTES:
EXISTING CARD READER TO BE REPLACED WITH NEW. INSTALL NEW REX. RE-USE ALL OTHER
EXISTING ACCESS CONTROL EQUIMPENT.
ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH
PROTECTOR AND SECURITY HINGES.
INSTALL NEW INTERIOR 1MP CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
INSTALL NEW EXTERIOR 270 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND
INTEGRATE INTO THE NEW CCTV SYSTEM.
EXISTING
RE-USE MAG LOCK
EXISTING - SEE NOTE 2 BELOW
MAG
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
EXISTING
RE-USE ELECTRIC CRASHBAR
EXISTING - SEE NOTE 2 BELOW
EXISTING
RE-USE PUSH BUTTON
EXISTING - SEE NOTE 2 BELOW
ECB
A1/53-107
NN
CAT6 PLENUM A1/51-101
270 DEGREE CAMERA
270 DEGREE
B
RADIO ROOM OPS
WILDLIFE FIRE RISERRGE/RECBOILER
ELEC.
WAREHOUSE
K
STORAGE
C O
R R
I D
O R
10-104
DOOR-105
2 3
CAM-103
CAM-108
270 DEGREE
S
K
DOOR-115
ES
K
270 DEGREE
DOOR-118
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-105
10-105
SECTION - PLANS
WORLAND FIELD OFFICE
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
CONTINUED
WORLAND FIELD OFFICE
A1
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
K
FIXED INTERIOR 1MP CAMERA
CARD READER W/ KEYPAD
REQUEST TO EXIT
DOOR POSITION SWITCH
CAT6 PLENUM
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
A1/51-103
A1/53-108
ES
ELECTRIC STRIKE
COMPONENT
NOTES:
EXISTING CARD READER TO BE REPLACED WITH NEW. INSTALL NEW REX, DOOR POSITION
SWITCH, AND ELECTRIC STRIKE.
ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH
PROTECTOR AND SECURITY HINGES.
INSTALL NEW INTERIOR 1MP CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.
INSTALL A NEW EXTERIOR 270 DEGREE CAMERA WITH A BUILT IN
IR ILLUMINATOR AND INTEGRATE INTO THE NEW CCTV SYSTEM.
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
INSTALL NEW CARD READER, REX, ELECTRIC STRIKE, AND DOOR POSITION SWITCH.
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-107
TBD/53-108
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
NN
CAT6 PLENUM
270 DEGREE CAMERA
A1/51-101
270 DEGREE
B
CONFERENCE
ELEVATOR
MECHANICAL
R.R.
CORRIDOR
STAIRWELL
C O
R R
I D
O R
R.R.
K
K
K
VESTIBULE
K
O F
F I C
E
PUBLIC ROOM
O F
F I C
E M
G R
10-103
ELECTRICAL
C O
R R
I D
O R
COPY ROOM
STORAGE
C O
R R
I D
O R
RECEPTION
LOBBY
CLOSET
K
HPBHPB
0 ° F I S
H
E
C
A
M
E
R
A
DVR
VESTIBULE
OFFICE AREA
LOCKER ROOM
CAM-106
DOOR-107
DOOR-104
CAM-105
DOOR-105
CAM-104
CR-115
DOOR-114
DOOR-106
S
CAM-109
FISHEYE
K
180 DEGREE
K
DOOR-116
DOOR-117
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-106
10-106
SECTION - PLANS
WORLAND FIELD OFFICE
A1
WORLAND FIELD OFFICE
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
CONTINUED
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
K
FIXED INTERIOR 1MP CAMERA
CARD READER W/ KEYPAD
REQUEST TO EXIT
RE-USE DOOR POSITION SWITCH
CAT6 PLENUM
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
A1/51-103
A1/53-108
ES
RE-USE ELECTRIC STRIKE
COMPONENT
DURESS SWITCH
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/52-104
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
NOTES:
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS
INSTALL NEW DOOR POSITION SWITCH, MAG LOCK, AND PUSH BUTTON RELEASE.
ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH
PROTECTOR AND SECURITY HINGES.
INSTALL MONITOR FOR CCTV SUPERVISION. EXACT LOCATION TO BE DETERMINED BY
AUTHORIZED ON-SITE PERSONNEL.
INSTALL NEW INTERIOR 1 MP CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.
EXISTING EQUIPMENT AND ASSOCIATED WIRING TO BE REMOVED AND RETURNED TO
CUSTOMER.
INSTALL A NEW EXTERIOR 180 DEGREE CAMERA WITH A BUILT IN
IR ILLUMINATOR AND INTEGRATE INTO THE NEW CCTV SYSTEM.
INSTALL NEW CARD READER, REX, DOOR POSITION SWITCH, AND ELECTRIC STRIKE.
EXISTING
RE-USE MAG LOCK
EXISTING - SEE NOTE 2 BELOWMAG
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
EXISTING
EXISTING - SEE NOTE 2 BELOW
EXISTING
EXISTING - SEE NOTE 2 BELOW
REMOVE EXISTING
DIGITAL VIDEO RECORDER
DVR
EXISTING
360 DEGREE FISHEYE CAMERA CAT6 PLENUM A1/51-104
RE-USE PUSH BUTTON
EXISTING
EXISTING - SEE NOTE 2 BELOW
NN
A4/52-104
CAT6 PLENUM
180 DEGREE CAMERA
A1/51-101
180 DEGREE
FISHEYE
CLIENT WORKSTATION
WITH MONITOR
D1/51-105
D4/54-103
B
MANAGER
OFFICE
OFFICE
OFFICE AREA
10-102
S
2 3
S
2 3
S
2 3
S
2 3
S
2 3
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-107
10-107
SECTION - PLANS
WORLAND FIELD OFFICE
A1
WORLAND FIELD OFFICE
0'-0" 8'-0"
SCALE: 1/8" = 1'
10-102 10-103
10-104
10-105
10-107 10-106
KEY PLAN
WORLAND FIELD OFFICE
ENLARGED FLOOR PLAN
WITH CCTV FOV(S) AND
DEVICE LOCATIONS
CONTINUED
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
COMPONENT
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
NOTES:
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS
NN
A4/52-104
B
CONFERENCE
MANAGER
FOI
MECH.
UTILITY
R.R.
R.R.
ELEC.
BREAK
ELEVATORRECEPTION
OFFICE
MANAGER
STAIRWELL
OFFICE AREA
OFFICE AREA
OFFICE AREA
COPY / FILES
OFFICE
IT/SETUP
FILE ROOM
OFFICEOFFICE
OFFICE
I.T. ROOM
OFFICE OFFICE
C O
R R
I D
O R
C O
R R
I D
O R
E1
10-109
ENLARGED
PLAN
A4
10-109
ENLARGED
PLAN
C4
10-109
ENLARGED
PLAN
C1
10-109
ENLARGED
PLAN
A1
10-109
ENLARGED
PLAN
S
S
S
ROOM
S
S
2 3
S
2 3
S
2 3
S
S
2 3
S
2 3
S
2 3
S
S
2 3
S
S
2 3
S
2 3
S
2 3
S
2 3
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-108
10-108
SECTION - PLANS
WORLAND FIELD OFFICE
WORLAND FIELD OFFICE
A1
WORLAND FIELD OFFICE
2ND FLOOR REFERENCE
PLAN AND STROBE
LOCATIONS
0'-0" 16'-0"
SCALE: 1/16"=1'
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
COMPONENT
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
NOTES:
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS
INSTALL NEW CARD READER, REX, DOOR POSITION SWITCH, AND ELECTRIC STRIKE AT THIS
DOOR LOCATION.
NN
A4/52-104
B
IT/SETUP
OFFICEOFFICE
I.T. ROOM
OFFICE OFFICE
C O
R R
I D
O R
DOOR-113
ACP
DURESS
UPS
SERVER
WIRELESS
K
C/CL
SWITCH
NVR
K
OFFICE AREA
OFFICE AREA
MAG
DOOR-112
CAM-108
K
ELEVATOR
RECEPTION
OFFICE
MANAGER
STAIRWELL
ES
DOOR-111
CAM-107
K
FILE ROOM
OFFICE
OFFICE AREA
FILE ROOM
DOOR
K
ES
MANAGER
FOI
MECH.
UTILITY
C O
R R
I D
O R
FOI DOOR
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-109
10-109
SECTION - PLANS
WORLAND FIELD OFFICE
WORLAND FIELD OFFICE
2ND FLOOR ENLARGED
PLAN SHOWING
SECURITY EQUIPMENT
AND CAMERA FIELD(S) OF
VIEW
0'-0" 8'-0"
SCALE: 1/8" = 1'
WORLAND FIELD OFFICE
A1
WORLAND FIELD OFFICE
C1
WORLAND FIELD OFFICE
C4
WORLAND FIELD OFFICE
A4
WORLAND FIELD OFFICE
E1 E3
0'-0" 8'-0"
SCALE: 1/8" = 1'
0'-0" 8'-0"
SCALE: 1/8" = 1'
K
CARD READER W/ KEYPAD
RE USE DOOR POSITION SWITCH
EQUIPMENT REFERENCE CHART
WIRING DETIALSSYMBOL
EQUIPMENT REFERENCE CHART
COMPONENT
MCL
MECHANICAL
CIPHER-LOCK
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
ACP
SEE DETAIL
ACCESS CONTROL PANEL
A1/53-101
DURESSDURESS SYSTEM
A1/52-103
UNINTERRUPTIBLE
POWER SUPPLY
UPS
NETWORK VIDEO RECORDER
NVR
E1/54-102
WIRELESS
DURESS WIRELESS RECEIVER
AND WIRELESS PUSHBUTTONS
D1/52-104
D4/52-104
TBD
SEE DETAIL
REQUEST TO EXIT
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-108
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
NOTES:
EXACT MOUNTING LOCATIONS OF LOCAL PROCESSOR SHALL BE VERIFIED BY ONSITE
REPRESENTATIVE PRIOR TO INSTALLATION.
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
EXISTING CARD READER TO BE REPLACED WITH NEW, INSTALL NEW REQUEST TO EXIT.
INSTALL A RKCL40 CARD READER FOR HIGH SECURITY AT THIS LOCATION.
INSTALL MONITOR FOR CCTV SUPERVISION. EXACT LOCATION TO BE DETERMINED BY
AUTHORIZED ON-SITE PERSONNEL.
CONTRACTOR TO PROCURE AND INSTALL A NEW UPS THAT IS CAPABLE OF SUPPLYING
POWER TO THE ACCESS CONTROL SYSTEM, DURESS SYSTEM AND THE CCTV SYSTEM FOR
A MINIMUM OF 30 MINUTES.
INSTALL NEW ACS SERVER, MANAGED SWITCH, KVM SWITCH, NETWORK VIDEO RECORDER
AND MONITOR.
EXISTING EQUIPMENT TO REMAIN.
REMOVE EXISTING CIPHER LOCK AND INSTALL NEW CARD READER, REX, DOOR POSITION
SWITCH, AND ELECTRIC STRIKE
INSTALL NEW INTERIOR 1MP CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.
N/A A1/53-104
EXISTING - SEE NOTE 2 BELOW
EXISTING
ES
EXISTING
RE-USE ELECTRIC STRIKE
EXISTING - SEE NOTE 2 BELOW
EXISTING
RE-USE MAG LOCK
EXISTING - SEE NOTE 2 BELOW
MAG
NN
NN
NN
A4/52-104
CLIENT WORKSTATION
WITH MONITOR
D1/51-105
D4/54-103
K
C/CL
CONTACT/ CONTACTLESS
CARD READER W/ KEYPAD
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-106
SERVER
SWITCH
SEE DETAIL
ACS SERVER
NETWORK SWITCH E1/54-103
A1/54-102
SEE DETAIL
FIXED INTERIOR 1MP CAMERA CAT6 PLENUM A1/51-103
B
DOOR-201
DOOR-202
S
2 3
S
2 3
K
K
1" UNDERGROUND CONDUIT TO
EXISTING LIGHT POLES
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E
L17PD00123
JULY 21, 2020
7-21-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
WORLAND FIELD OFFICE
BLM-WFO-10-201
10-201
SECTION - PLANS
WORLAND FIELD OFFICE
SHOP BUILDING FLOOR
PLAN SHOWING EXISTING
DEVICES AND CCTV
FOV(S)
WORLAND FIELD OFFICE
A1
N
WORLAND FIELD OFFICE
SCALE: 1" = 10'
0'-0" 10'-0"
NOTE: NO CUSTOMER SUPPLIED FLOOR PLAN FOR THIS BUILDING. ONLY EXTERIOR WALLS ARE SHOWN FOR
DEVICE LAYOUT PURPOSES. PLAN MAY NOT MATCH EXISTING CONDITIONS.
EQUIPMENT REFERENCE CHART
WIRINGSYMBOL
EQUIPMENT REFERENCE CHART
WIRINGSYMBOLCOMPONENT WIRINGSYMBOL
EQUIPMENT REFERENCE CHART
COMPONENT
NOTE: NO CUSTOMER SUPPLIED FLOOR PLAN FOR THIS BUILDING. ONLY EXTERIOR WALLS ARE SHOWN FOR
DEVICE LAYOUT PURPOSES. PLAN MAY NOT MATCH EXISTING CONDITIONS.
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
NOTES:
REPLACE CARD READER AND INSTALL NEW CARD READER, REX, AND DOOR POSITION SWITCH.
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
TRENCH FROM THE GARAGE TO THE EXISTING LIGHT POLES.
INSTALL A 1" CONDUIT IN THE TRENCH FOR THE (2) 180 DEGREE CAMERAS AND THE(1) 5MP FIXED
CAMERA THAT IS TO BE MOUNTED ON THE EXISTING POLES. CAMERAS ARE TO HAVE BUILT IN
IR ILLUMINATORS. COVER THE TRENCH AFTER INSTALLATION AND RE-ASPHALT OVER THE TRENCH.
INSTALL A NEW 8 PORT POE SWITCH TO POWER THE CAMERAS. SWITCH WILL NEED TO CONNECT
TO THE SWITCH INSIDE THE MAIN OFFICE BUILDING VIA EXISTING UNDERGROUND CONDUIT.
K
CARD READER W/ KEYPAD
REQUEST TO EXIT
DOOR POSITION SWITCH
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
A1/53-108
ES
ELECTRIC STRIKE
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-107
TBD/53-108
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
CAT6 PLENUM A1/51-101
180 DEGREE CAMERA
180 DEGREE
B
File details come from the government source that posted it. Updated .