CODY_FIELD_OFFICE_BID_SET_08_24_21_0001.pdf

PDF 1 MB Posted

Attached to
BLM WYOMING WORLAND AND CODY SECURITY SYSTEMS Federal contract opportunity
Solicitation number
140L6221R0039
Issued by
Department of the Interior Bureau of Land Management Wyoming Region

About this file

This set of construction drawings and specifications is for security system upgrades at the Bureau of Land Management's Worland and Cody Field Offices in Wyoming. The upgrades include access control, intrusion detection, video surveillance, and duress systems. Card readers, electric strikes, door position switches, and request-to-exit devices will control entry to buildings. Exterior and interior cameras will provide video surveillance of buildings and grounds. Duress buttons and notification to local authorities are included. Network video recorders, servers, switches and UPS backup will be installed. Site plans, floor plans and equipment details are provided for contractor bidding and installation of the new systems.

View the file

Other files for this federal contract opportunity

Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUREAU OF LAND MANAGEMENT

CODY FIELD OFFICE

1002 BLACKBURN ST.

CODY, WY 82414

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CODY FIELD OFFICE

BLM-CFO-01-101

01-101

SECTION - GENERAL

COVER SHEET

© 2017 GOOGLE© 2017 GOOGLE© 2017 GOOGLE

B

I

D

S

E

T

O

N

L

Y

XX

XX

XX

GENERAL SYMBOLS

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

ELEVATION NUMBER

SHEET NUMBER

SECTION NUMBER

DETAIL NUMBER

DETAIL DESCRIPTION

ADDITIONAL DETAIL INFORMATION

SHEET NUMBER

AREA OF INCLUSION

00-000

2c 18 AWG

NUMBER OF CONDUCTORS

GAUGE OF WIRE

FILE NUMBER DESIGNATION

XXX-XXX-XX-XXX

FACILITY DESIGNATOR

LOCATION DISCIPLINE DESIGNATOR

DRAWING TYPE DESIGNATOR

3-4 DIGIT SEQUENTIAL PAGE NUMBER

0 - GENERAL (SYMBOLS LEGEND, NOTES, ETC.)

01 COVER SHEET

02 SYMBOLS PAGE

03 ABBREVIATIONS

04 DRAWING INDEX

05 EQUIPMENT LISTS

1 - PLANS (HORIZONTAL VIEWS)

10 - PLAN VIEWS

A. OVERALL PLAN VIEWS

B. SPECIFIC BUILDING PLAN VIEWS

C. ENLARGED PLAN VIEWS

11 - ELECTRICAL & CABLING

A. PLAN VIEWS SHOWING ELECTRICAL CONDUIT RUNS

B. PLAN VIEWS SHOWING FIBER OPTIC CONDUIT RUNS

C. JUNCTION BOX LOCATIONS

D. WIRE DETAILS OF SIZE, QUANTITY

2 - ELEVATIONS (VERTICAL VIEWS)

3 - SECTIONS (SECTIONAL VIEWS)

4 - LARGE-SCALE VIEWS

(PLANS, ELEVATIONS OR SECTIONS THAT ARE NOT DETAILS)

5 - DETAILS

6 - SCHEDULES AND DIAGRAMS

60 - BLOCK DIAGRAMS

61 - ONE-LINE DIAGRAMS

62 - EQUIPMENT INTERCONNECTION DIAGRAMS

63 - WIRING DIAGRAMS NOT SPECIFIC TO EQUIPMENT

64 - TELECOMMUNICATIONS DIAGRAMS

65 - EQUIPMENT SCHEDULES

66 - PROGRAMMING SCHEDULES

67 - RACEWAY/CIRCUIT SCHEDULES

DRAWING TYPE DESIGNATOR

(PER ERDC/ITL TR-06-X; TABLE 2-3)

NOTE: PAGE NUMBER IS AN ABBREVIATED VERSION OF THE FILE NUMBER

WIRE GAUGE DESIGNATION

XX-XXX

XX-XXX

XX-XXX

1. GENERAL NOTES ON THIS SHEET APPLY TO ALL DRAWINGS.

2. LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS

ON THE SET OF DRAWINGS. ADDITIONAL LEGENDS AND/OR OTHER LEGEND SHEETS MAY

APPEAR ON SPECIFIC DRAWINGS TO INDICATE SPECIFIC CONDITIONS.

3. NEWLY INSTALLED ENCLOSURES, CABINETS, HOUSINGS, BOXES AND FITTINGS HAVING HINGED

DOORS OR REMOVABLE COVERS AND WHICH CONTAIN CIRCUITS OR CONNECTIONS OF THE

ACS SYSTEM AND ITS POWER SUPPLIES, SHALL BE PROVIDED WITH COVER OPERATED,

CORROSION RESISTANT TAMPER SWITCHES, ARRANGED TO INITIATE AN ALARM SIGNAL

WHEN THE DOOR OR COVER IS MOVED. THE ENCLOSURE AND THE TAMPER SWITCH SHALL

FUNCTION TOGETHER AND SHALL NOT ALLOW DIRECT LINE OF SIGHT TO ANY INTERNAL

COMPONENTS BEFORE THE SWITCH ACTIVATES. TAMPER SWITCHES SHALL BE

INACCESSIBLE UNTIL THE SWITCH IS ACTIVATED; HAVE MOUNTING HARDWARE

CONCEALED SO THAT THE LOCATION OF THE SWITCH CANNOT BE OBSERVED FROM THE

EXTERIOR OF THE ENCLOSURE; BE CONNECTED TO CIRCUITS WHICH ARE UNDER

ELECTRICAL SUPERVISION AT ALL TIMES, IRRESPECTIVE OF THE PROTECTION MODE IN

WHICH THE CIRCUIT IS OPERATING; SHALL BE SPRING-LOADED AND HELD IN THE

CLOSED POSITION BY THE DOOR OR COVER; AND SHALL BE WIRED SO THAT THE

CIRCUIT IS BROKEN WHEN THE DOOR OR COVER IS DISTURBED.

4. ACCESS CONTROL SYSTEM EQUIPMENT MUST BE EQUIPPED WITH CONTINUOUSLY MONITORED

TAMPER DETECTION DEVICES REGARDLESS OF WHETHER THE SYSTEM IS IN THE ACCESS OR

SECURE MODE OF OPERATION. UPON DETECTION, AN ALARM (NOT FAULT) CONDITION MUST BE

TRANSMITTED TO THE PCU OR MONITORING STATION.

5. EXACT MOUNTING LOCATION OF ACS, DAS, CCTV SHALL BE VERIFIED PRIOR TO INSTALLATION.

6. ALL EXTERIOR HOUSING ENCLOSURE BOXES SHALL BE NEMA 4X RATED.

7. CONTRACTOR SHALL INSTALL A WARNING UNDERGROUND MARKER TAPE ABOVE ALL SECURITY

UNDERGROUND DUCTBANKS. IT SHALL BE SOLID FOIL MARKER TAPE, ORANGE, 3 INCHES WIDE, DETECTABLE, NON-DEGRADABLE, CORROSION RESISTANT, TEAR RESISTANT AND WITH

1 1/4 INCH STENCILED BLACK NON-DEGRADABLE LETTERS. WORDING ON MARKERS READ

"CAUTION DUCTBANK BURIED BELOW." TRACER WIRE SHALL BE INCLUDED WITH ALL DIRECTIONAL BORING.

8. ALL FIELD DISTRIBUTION BOXES AND SECURITY EQUIPMENT CABINETS SHALL HAVE A GROUNDING

LUG OR A GROUNDING BUS BAR INSTALLED.

9. ALL COPPER WIRE TERMINATIONS SHALL HAVE AT LEAST A 3'-0" (0.91m) SERVICE

LOOP AT EACH END. ALL ESS WIRING SHALL HAVE AT LEAST 3'-0" BETWEEN A SURGE

PROTECTOR AND A DEVICE.

10. IF ANY REQUIRED INFORMATION IS NOT CONTAINED WITHIN THIS SET OF DRAWINGS, REFER TO

MANUFACTURER SUPPLIED INSTRUCTIONS.

11. THESE DRAWINGS ARE DIAGRAMITC IN NATURE AND ARE NOT INTENDED TO SHOW EXACT CONDITIONS

AS MAY EXIST UNLESS NOTED OTHERWISE.

12. DO NOT SCALE DRAWINGS AS PROVIDED SCALES ARE FOR REFERENCE ONLY.

13. THE SCALES APPLIED TO THE DRAWINGS ARE BASED OFF U.S. CUSTOMARY UNITS STANDARD.

GENERAL NOTES

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

GENERAL INFORMATION

CODY FIELD OFFICE

BLM-CFO-01-102

01-102

SECTION - GENERAL

B

MCL

NOTE: ABBREVIATIONS LISTED ARE BASED ON INDUSTRY STANDARDS AND ALL MAY NOT BE APPLICABLE TO PROJECT.

ABBREVIATIONS SECURITY LEGEND

ALARM INTERFACE

CENTRAL PROCESSING UNIT

ELECTRONIC ENTRY CONTROL SYSTEM

HAND GEOMETRY UNIT

INTRUSION DETECTION SYSTEM

ACC/SEC

BMS

CJB

CPU

CR

ECE

EECS

HGU

IDS

DCM DOOR CONTROL MODULE

CARD READER

CU COPPER

EMT ELECTRICAL METALLIC TUBING

BALANCED MAGNETIC SWITCH

ENROLLMENT CENTER EQUIPMENT

H

DC DIRECT CURRENT

CTL CONTROL

AMP

ABOVE FINISHED FLOOR

AMPERE

EP EXPLOSION PROOF

AIF ACTIVE INFRARED SENSOR

DIB DEVICE INTERFACE BOX

CLOSED CIRCUIT TELEVISIONCCTV

CAMERA JUNCTION BOX

CTW CAMERA TOWER

DB

AFF

DP DISTRIBUTION POWER

AWG AMERICAN WIRE GAUGE

AUX

APPROX APPROXIMATELY

AUXILIARY

ADMIN ADMINISTRATOR

BLDG BUILDING

CAB

C

CABINET

COMM COMMUNICATION

DIST DISTANCE

ELECT ELECTRICAL

EQ EQUAL

EQUIP EQUIPMENT

ENCL ENCLOSURE

UNDERGROUND DUCTBANK

EHH ELECTRICAL HAND HOLE

HIGH

BAT BATTERY

BC BATTERY CHARGER

DVR DIGITAL VIDEO RECORDER

EMI ELECTROMAGNETIC INTERFERENCE

EMH

ELECTRICAL MANHOLE

CONDUIT

ERAC

BPS BYPASS SWITCH PANEL

ELEVATIONEL

FOP FIBER OPTIC DISTRIBUTION PANEL

FORX

FOT

FIBER OPTIC RECEIVER MODULE

FIBER OPTIC TRANSMISSION PANEL

GND GROUND

FDB FIELD DISTRIBUTION BOX

GALV GALVANIZED

GB GLASS BREAK

FOSC FIBER OPTIC SENSOR CABLE

(F) FUTURE

FO FIBER OPTIC

FOCC FIBER OPTIC I/O CONVERTER

GS GATE SENSOR SWITCH

GSB GATE SENSOR SWITCH JUNCTION BOX

FOB FIBER OPTIC BOX

FOSS FIBER OPTIC SENSOR SYSTEM

EXT EXTERIOR

EQUIPMENT RACK AIR CONDITIONER

FFOM FENCE FIBER OPTIC MODULE

FFOR FENCE FIBER OPTIC RACK

FOM FIBER OPTIC MODULE

FOPP FIBER OPTIC PATCH PANEL

FOR FIBER OPTIC RACK

I/O INPUT/OUTPUT

RIGID GALVANIZED STEEL

STAINLESS STEEL

RGS

SST

UPS

VM

REX

TSL TURNSTILE

SSC

TA

TAS

TROUBLE ALARM

T

TBD TO BE DETERMINED

REQ'D REQUIRED

SW SWITCH

TB TERMINAL BLOCK

W

VIDEO MONITOR

UNINTERRUPTIBLE POWER SUPPLY

TAMPER ALARM SWITCH

REQUEST TO EXIT DEVICE

V VOLTAGE

ST STRAIGHT TIP

SP SPARE

QTY QUANTITY

PR PAIR

WIDTH

PWS POWER SUPPLY ENCLOSURE

SSB SURGE SUPPRESSION BOX

TWF TAUT WIRE FENCE ALARM AREA

PP POWER PANEL

TRANSFORMER/TAMPER

UL

UNDERWRITERS LABORATORIES

TYP TYPICAL

WHT WHITE

W/ WITH

OH OVERHEAD

REC RECEIVING

SO FLEXIBLE POWER CORD

SQ SQUARE

SHH SECURITY HAND HOLE

VLS VEHICLE LOOP SENSOR

TV TELEVISION

THHN 90°, 600 VOLT NYLON JACKETED

BUILDING WIRE FOR DRY LOCATIONS

SS

SCMS SITE CONTROL AND MONITORING

SYSTEM

PNL PANEL

PTZ PAN TILT AND ZOOM

PVC POLYVINYL CHLORIDE

GATE SAFETY SENSOR

SURGE SUPPRESSOR-COAX

SSDA SURGE SUPPRESSOR-DATA

SSP SURGE SUPPRESSOR-POWER

SPDT SINGLE POLE DOUBLE THROW

SWGR SWITCHGEAR

WS WORK STATION

OSSC

PS POWER SUPPLY

SCH SCMS HUB

SCP

SCW

SCWC

SCMS PRINTER

SCMS WORKSTATION

SCMS WORKSTATION CONSOLE

LP

LOPA LOSS OF POWER ALARM

NTS NOT TO SCALE

NO

NC NORMALLY CLOSED

NORMALLY OPEN

lbs POUNDS

LED LIGHT EMITTING DIODE

LAN LOCAL AREA NETWORK

MSR MAIN SERVICE ROAD

NO. NUMBER

NOT IN CONTRACTNIC

KBD

KPD

CCTV KEYBOARD

KEYPAD

JUNCTION BOXJB

MLIB

MON

MATRIX LOOPING INPUT BAY

MECH MECHANICAL

MONITOR

CCTV ALARM INTERFACE UNITTVAI

CCTV CENTRAL PROCESSING UNITTVCP

LANU LOCAL AREA NETWORK UNIT

TP TELEPHONE DISTRIBUTION PANEL

LSI LEAD SYSTEM INTEGRATOR

SPP SECURITY POWER PANEL

VID VIDEO

LOCAL PROCESSOR

ON-SITE SUPPORT CENTER

SJB SECURITY JUNCTION BOX

HS HATCH SWITCH

HVR HIGH VOLTAGE RELAY

LCD LIQUID CRYSTAL DISPLAY

RECP RECEPTACLE

RTC REMOTE TERMINAL CONTROLLER

AS ALARM SOUNDER

ECU ELECTRIC CYLINDER UNLATCH

A:

B:

C:

D:

E:

F:

G:

H:

I:

J:

K:

L:

MBS MATRIX BAY SWITCH

M:

N:

O:

P:

Q:

R:

S:

T:

U:

V:

W:

TIC TELEPHONE INTERCOM

VAC VOLTAGE ALTERNATING CURRENT

VDC VOLTAGE DIRECT CURRENT

ITS INFRASTRUCTURE TAMPER SWITCH

ES ELECTRIC STRIKE

BMX BISTATIC MICROWAVE TRANSMITTER

BMR BISTATIC MICROWAVE RECEIVER

MS MAGNETIC SWITCH

SDR SECURITY DOOR/GATE

CAM CAMERA

OPR GATE OPERATOR

DT DUAL TECHNOLOGY MOTION SENSOR

DS DURESS SWITCH

HEAT DETECTORHD

PREX PUSH-ACTIVATED REQUEST TO EXIT

STR STROBE

HORNHRN

PB PUSH BUTTON

MAG ELECTROMAGNETIC LOCK

HWS HORN WITH STROBE

MIC MICROPHONE

FAK FIRE ALARM KEYPAD

SD SMOKE DETECTOR

PIR PASSIVE INFRARED

MM MONOSTATIC MICROWAVE

SM SINGLE MODE FIBER OPTIC

SEC SECURITY EQUIPMENT CABINET

WAP WIRELESS ACCESS POINT

CPL CAMERA POLE

CAS FIBER OPTIC CASSETTE

EX EXISTING

WDS WIRELESS DURESS SWITCH

AN ANNUNCIATOR

DPS DOOR POSITION SWITCH

ACCESS CONTROL MODULEACM

IR INFRARED

HPB HANDICAP PUSH BUTTON

INTERCOMINT

DAS DURESS ALARM SYSTEM

DPDT DOUBLE POLE DOUBLE THROW

ECB ELECTRIC CRASH BAR

EML ELECTRIC MORTISE LOCK

FOPC FIBER OPTIC PATCH CASSETTE

FIELD OF VIEW

FOTC

FOTX

FOV

FIBER OPTIC TRANSCEIVER MODULE

FIBER OPTIC TRANSMITTER MODULE

FEETFT

F CONTINUED:

GCM GENERAL CONTROL MODULE

INTERCOM MASTERINT/M

INTERMEDIATE METALLIC CONDUIT IMC

NVR NETWORK VIDEO RECORDER

SPST SINGLE POLE SINGLE THROW

FJB FIBER OPTIC JUNCTION BOX

HH HAND HOLE

MCB MECHANICAL CRASH BAR

MCL MECHANICAL CIPHER LOCK

PUSH BUTTON

CARD READER

CONTACTLESS CARD READER W/ KEYPAD

REQUEST TO EXIT

INTERCOM

ELECTRIC STRIKE

ELECTROMAGNETIC LOCK

ACCESS CONTROL PANEL

DURESS SYSTEM

EQUIPMENT GROUND

STROBE

POLE

NORTH ARROWS

UNINTERRUPTABLE POWER SUPPLY

ACS

FIXED CAMERA

DIGITAL 180° FIXED CAMERA

DIGITAL 270° FIXED CAMERA

WIRELESS ACCESS POINT

CCTV

IDS

ALARM KEYPAD

(ALARM INTERFACE)

DOOR POSITION SWITCH

WIDE GAP

DURESS SWITCH

CHAIN LINK FENCE

GENERAL SYMBOLS

DOOR POSITION SWITCH

ELECTRICALLY OPERATED CRASH BAR

REFERENCED NOTE

DETAIL REFERENCE

XX-XXX

UPS

ECB

MAG

K

N

BALANCED MAGNETIC SWITCH

UL LEVEL 2, HIGH SECURITYHS

BALANCED MAGNETIC SWITCH

ES

CONTACT/CONTACTLESS CARD READER W/ KEYPAD

K

C/CL

MECHANICAL CIPHER LOCK

W

180 DEGREE

270 DEGREE

D

360° FISH EYE CAMERA

ACP

DURESS

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

ABBREVIATIONS &

SECURITY LEGENDS

CODY FIELD OFFICE

BLM-CFO-01-103

01-103

SECTION - GENERAL

B

DRAWING INDEX

GENERAL SHEET #

BLM-CFO-01-101 COVER SHEET 01 OF 09

BLM-CFO-01-102 GENERAL INFORMATION 02 OF 09

BLM-CFO-01-103 ABBREVIATIONS AND SECURITY LEGENDS 03 OF 09

BLM-CFO-01-104 DRAWING INDEX 04 OF 09

BLM-CFO-01-105 EQUIPMENT LIST 05 OF 09

PLANS SHEET #

BLM-CFO-10-001 CODY FIELD OFFICE SITE REFERENCE PLAN 06 OF 09

BLM-CFO-10-002 CODY FIELD OFFICE SITE PLAN WITH CCTV FOV(S) 07 OF 09

BLM-CFO-10-101 CODY FIELD OFFICE FLOOR REFERENCE PLAN WITH DEVICE LOCATIONS 08 OF 09

BLM-CFO-10-102 CODY FIELD OFFICE GARAGE FLOOR REFERENCE PLAN WITH DEVICE LOCATIONS 09 OF 09

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

DRAWING INDEX

CODY FIELD OFFICE

BLM-CFO-01-104

01-104

SECTION - GENERAL

B

EQUIPMENT LIST

NOTE: EQUIPMENT LISTED REPRESENTS PRIMARY COMPONENTS ONLY AND IS NOT AN ALL INCLUSIVE LIST FOR A FULLY FUNCTIONING SYSTEM.

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

EQUIPMENT LIST

CODY FIELD OFFICE

BLM-CFO-01-105

01-105

SECTION - GENERAL

B

XXXXXXXXX

X X

X

X X

X X X

X X

X X

X X X

X X

X X

X X X

X X

X X X

X X

X X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

SHED SHED

A1

10-101

FLOOR PLAN

A1

10-201

FLOOR PLAN

GARAGE

B L

A C

K B

U R

N

A

V E

P A

R K

I N

G

EXISTING

BUILDING

C O

F

E

F

I C

E

S I D

E W

A L

K

S I D

E W

A L

K

P A

R K

I N

G

S E

C U

R

P

A R

K I N

G

PARKING

EXISTING PERSONNEL

GATE

EXISTING MANUAL

VEHICLE GATE

EXISTING FENCE TYPICAL

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CODY FIELD OFFICE

N

SITE REFERENCE PLAN

A1 SCALE: 1" = 30'

0'-0" 30'-0"

BLM-CFO-10-001

10-001

SECTION -PLANS

CODY FIELD OFFICE

SITE REFERENCE PLAN

B

XXXXXXXXX

X X

X

X X

X X X

X X

X X

X X X

X X

X X

X X X

X X

X X X

X X

X X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

SHED SHED

A1

10-101

FLOOR PLAN

GARAGE

B L

A C

K B

U R

N

A

V E

P A

R K

I N

G

EXISTING

BUILDING

C O

E

F

I C

E

S I D

E W

A L

K

S I D

E W

A L

K

P A

R K

I N

G

S E

C U

R

P

A R

K I N

G

PARKING

EXISTING PERSONNEL

GATE

EXISTING MANUAL

VEHICLE GATE

EXISTING FENCE TYPICAL

A1

10-201

FLOOR PLAN

270 DEGREE

270 DEGREE270 DEGREE

270 DEGREE

270 DEGREE

CONTRACTOR TO INSTALL NEW TRENCH TO EXISTING

POLES AND TO THE SHED FOR NEW CAMERAS.

INSTALL A NEW 1" UNDERGROUND CONDUIT TO THE

EXISTING POLES AND NEW CAMERAS.

COVER TRENCH AND RE-ASPHALT . SEE DWG 10-201

180 DEGREE

180 DEGREE

INSTALL NEW 180 DEGREE CAMERA ON

EXISTING LIGHT POLE. SEE DWG 10-201

INSTALL NEW 270 DEGREE CAMERA ON

EXISTING SHED. SEE DWG 10-201

N

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CODY FIELD OFFICECODY FIELD OFFICE

N

SITE PLAN W/ CCTVFOV(S)

A1 SCALE: 1" = 30'

0'-0" 30'-0"

BLM-CFO-10-002

10-002

SECTION -PLANS

CODY FIELD OFFICE

SITE PLAN WITH CCTV

FOV(S)

B

BREAK ROOM

LOCKER ROOM

WOMEN'S ROOM MEN'S ROOM

MANAGERS

OFFICE

OFFICE

MECH. ROOM

RANGER ROOM

LAN./ COMP./

PHONE ROOM

COPIER /

SUPPLY ROOM

CONFERENCE ROOM

RECEPT.

PUBLIC

R.R.

LOBBY

PUBLIC

CONFERENCE

ROOM

FILE ROOM

MAIL

VESTIBULE

OPEN

OFFICE

OPEN

OFFICE

ECB

MAG

K

ES

K

C/CL

DOOR-101

K

ES

DOOR-103

DOOR-104

K

ES

DOOR-105

K

ES

DOOR-106

ES

DOOR-107

K

ES

K

ES

DOOR-108

HCP

HCP

ECB

K

CAM-101

CAM-102

DOOR-102

CAM-110

CAM-109 CAM-112

CAM-111

CAM-108

CAM-104

CAM-103

UPS

ACS

DURESS

NVR

WIRELESS

5 8

CAM-105

S

S

S

S

S

270 DEGREE

270 DEGREE

270 DEGREE270 DEGREE

FISH EYE

CAM-113

S

S

S

S

S

N

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CODY FIELD OFFICE

N

CODY FIELD OFFICE

BLM-CFO-10-101

10-101

SECTION - PLANS

FLOOR PLAN W/ DEVICES

A1

SCALE: 1" = 10'

0'-0" 10'-0"

CODY FIELD OFFICE

FLOOR REFERENCE PLAN

WITH DEVICE LOCATIONS

K

CARD READER W/ KEYPAD

DOOR POSITION SWITCH

EQUIPMENT REFERENCE CHART

WIRING DETAILSSYMBOL

EQUIPMENT REFERENCE CHART

SSTROBE

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

6C 18 AWG STRANDED

SHIELDED PLENUM WIRE

A1/53-105

ACS

SEE DETAIL

ACCESS CONTROL SYSTEM

A1/53-101

DURESSDURESS SYSTEM

A1/52-103

UNINTERRUPTIBLE

POWER SUPPLY

UPS

NETWORK VIDEO RECORDER

NVR

E1/54-102

WIRELESS

DURESS WIRELESS RECEIVER

AND WIRELESS PUSHBUTTONS

D1/52-104

D4/52-104

CCTV MONITOR

HDMI

D1/51-105

TBD

SEE DETAIL

REQUEST TO EXIT

4C 18 AWG STRANDED

SHIELDED PLENUM WIRE

ES

ELECTRIC STRIKE

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

TBD/53-108

NOTES:

EXACT MOUNTING LOCATIONS OF LOCAL PROCESSOR SHALL BE VERIFIED BY ONSITE

REPRESENTATIVE PRIOR TO INSTALLATION.

INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT

TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE

CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK

ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.

TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE

BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH

SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF

OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR

COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.

INSTALL NEW CARD READER, REQUEST TO EXIT, DOOR POSITION SWITCH AND ELECTRIC STRIKE.

INSTALL NEW CARD READER AND INTEGRATE INTO NEW ACS SYSTEM.

CARD READER AT THIS DOOR SHALL BE A HID - RKCL40.

ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH

PROTECTOR AND SECURITY HINGES.

INSTALL MONITOR FOR CCTV SUPERVISION. EXACT LOCATION TO BE

DETERMINED BY AUTHORIZED ON-SITE PERSONNEL.

CONTRACTOR TO PROCURE AND INSTALL A NEW UPS THAT IS CAPABLE OF SUPPLYING

POWER TO THE ACCESS CONTROL SYSTEM, DURESS SYSTEM AND THE CCTV SYSTEM

FOR A MINIMUM OF 30 MINUTES.

INSTALL NEW NVR FOR NEW CCTV SYSTEM. NVR WILL BE RACK MOUNTED AND VERIFIED BY

ONSITE REPRESENTATIVE PRIOR TO INSTALLATION.

INSTALL NEW CLIENT COMPUTER WITH MONITOR FOR ACS. EXACT LOCATION TO BE

DETERMINED BY AUTHORIZED ON-SITE PERSONNEL.

INSTALL NEW INTERIOR 1MP CAMERA AND INTEGRATE INTO THE NEW CCTV SYSTEM.

INSTALL NEW EXTERIOR 270 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND INTEGRATE

INTO THE NEW CCTV SYSTEM.

EXISTING ELECTRIC CRASH BAR, REQUEST TO EXIT, HANDICAP PUSH BUTTON AND

ELECTROMAGNETIC LOCK TO BE INTEGRATED IN TO ASC SYSTEM.

INSTALL 360 DEGREE FISHEYE CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.

REMOVE EXISTING CYPHER LOCK.

HANDICAP PUSHBUTTONS TO BE TIED INTO NEW ACCESS CONTROL SYSTEM.

SYMBOL

GENERAL EQUIPMENT NOTES:

1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.

2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.

3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

TBD/53-107

CLIENT WORKSTATION

WITH MONITOR

DURESS SWITCH

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

A1/52-104

FIXED INTERIOR 1MP CAMERA CAT6 PLENUM A1/51-103

CAT6 PLENUM A1/51-101

270 DEGREE CAMERA

HIGH SECURITY

CARD READER W/ KEYPAD

6C 18 AWG STRANDED

SHIELDED PLENUM WIRE

A1/53-106

K

C/CL

COMPONENT

A1/53-108

A4/52-104

D1/51-105

D4/54-103

FISH EYE

CAT6 PLENUM

360 DEGREE FISH EYE CAMERA

A1/51-104

270 DEGREE

B

MCL-201

K

ES

180 DEGREE

1" UNDERGROUND CONDUIT TO SHED

CAM-114

N

MARK DATE

SHEET OF

2 3 4 5 6 7

1 2 3 4 5 6 7

A

B

C

D

E

F

DESCRIPTION

A

B

C

D

E

F

DESIGN BY

PROJECT IDENTIFICATION

CONTRACT NUMBER:

CAD DWG FILE:

DRAWN BY:

DESIGNED / CHECKED BY:

DATE:

SHEET TITLE

THIS BOX 2" @ 24x36

CLIENTELE

THIS BOX 1" @ 11x17

L. MORGAN

K.E.

140L6220P0043

JULY 3, 2020

7-3-201

INTEGRATED SECURITY

SOLUTIONS, INC.

108 COOPERATIVE WAY

KALISPELL, MT 59901

PHONE: 406-755-2504

BUREAU OF LAND

MANAGEMENT

NATIONAL OPERATIONS

CENTER

BLM WYOMING

STATEWIDE SECURITY

SYSTEM DESIGN

BID SET

CODY FIELD OFFICE

BLM-CFO-10-201

10-201

SECTION - PLANS

N

CODY FIELD OFFICE

FLOOR PLAN W/ DEVICES

A1

CODY FIELD OFFICE

GARAGE FLOOR

REFERENCE PLAN WITH

DEVICE LOCATIONS

0'-0" 8'-0"

SCALE: 1/8" = 1'

EQUIPMENT REFERENCE CHART

WIRING DETAILSSYMBOL

EQUIPMENT REFERENCE CHART

COMPONENT

K

CARD READER W/ KEYPAD

DOOR POSITION SWITCH

6C 18 AWG STRANDED

SHIELDED PLENUM WIRE

A1/53-105

REQUEST TO EXIT

4C 18 AWG STRANDED

SHIELDED PLENUM WIRE

ES

ELECTRIC STRIKE

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

TBD/53-108

2C 18 AWG STRANDED

SHIELDED PLENUM WIRE

TBD/53-107

A1/53-108

CAT6 PLENUM

A1/51-101

180 DEGREE CAMERA

180 DEGREE

NOTES:

INSTALL NEW CARD READER, REQUEST TO EXIT, DOOR POSITION

SWITCH AND ELECTRIC STRIKE. ACCESS CONTROL EQUIPMENT WILL CONNECT TO THE

ACCESS CONTROL PANEL LOCATED IN THE MAIN OFFICE BUILDING VIA EXISTING

UNDERGROUND CONDUIT.

TRENCH FROM THE GARAGE TO THE EXISTING POLES AND TO THE SHED.

INSTALL A 1" CONDUIT IN THE TRENCH FOR THE (1) 180 DEGREE CAMERA THAT IS TO BE

MOUNTED ON THE EXISTING POLE AND THE (1) 270 DEGREE CAMERA THAT IS TO BE

MOUNTED ON THE SHED. BOTH CAMERAS ARE TO HAVE BUILT IN IR ILLUMINATORS. COVER

THE TRENCH AFTER INSTALLATION AND RE-ASPHALT OVER THE TRENCH.

INSTALL (1) NEW EXTERIOR 180 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND

INTEGRATE INTO THE NEW CCTV SYSTEM.

INSTALL A NEW 8 PORT POE SWITCH TO POWER THE CAMERAS. SWITCH WILL NEED TO

CONNECT TO THE SWITCH INSIDE THE MAIN OFFICE BUILDING VIA EXISTING

UNDERGROUND CONDUIT.

GENERAL EQUIPMENT NOTES:

1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.

2. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.

B