CODY_FIELD_OFFICE_BID_SET_08_24_21_0001.pdf
PDF 1 MB Posted
- Attached to
- BLM WYOMING WORLAND AND CODY SECURITY SYSTEMS Federal contract opportunity
- Solicitation number
- 140L6221R0039
About this file
This set of construction drawings and specifications is for security system upgrades at the Bureau of Land Management's Worland and Cody Field Offices in Wyoming. The upgrades include access control, intrusion detection, video surveillance, and duress systems. Card readers, electric strikes, door position switches, and request-to-exit devices will control entry to buildings. Exterior and interior cameras will provide video surveillance of buildings and grounds. Duress buttons and notification to local authorities are included. Network video recorders, servers, switches and UPS backup will be installed. Site plans, floor plans and equipment details are provided for contractor bidding and installation of the new systems.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L6221R0039_Amd_0004.pdf | ||
| 140L6221R0039_AMD_0004_QUESTIONS_AND_ANSWERS_Final_0004.docx | DOCX document | |
| Sol_140L6221R0039_Amd_0003.pdf | ||
| 140L6221R0039_AMD_0003_CODY_FIELD_OFFICE_BID_SET_08_24_21_0003.pdf | ||
| 140L6221R0039_AMD_0002_QUESTONS_AND_ANSWERS_0002.docx | DOCX document | |
| Sol_140L6221R0039_Amd_0002.pdf | ||
| Vaccination_Certification_Notification_to_DOI_Contractors_0001.pdf | ||
| WORLAND_FIELD_OFFICE_BID_SET_08_24_21_0001.pdf | ||
| CertificationVaccinationPRAv7_Contractors_0001.pdf | ||
| Sol_140L6221R0039_Amd_0001.pdf | ||
| Cody_Field_Office_Security_System_Installation_Bid_Schedule.xlsx | XLSX spreadsheet | |
| Sol_140L6221R0039.pdf | ||
| BLM_Wyoming_Worland_and_Cody_Field_Office_Security_System_Installation_SOW.pdf | ||
| Worland_Field_Office_Security_System_Installation_Bid_Schedule.xlsx | XLSX spreadsheet |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUREAU OF LAND MANAGEMENT
CODY FIELD OFFICE
1002 BLACKBURN ST.
CODY, WY 82414
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
CODY FIELD OFFICE
BLM-CFO-01-101
01-101
SECTION - GENERAL
COVER SHEET
© 2017 GOOGLE© 2017 GOOGLE© 2017 GOOGLE
B
I
D
S
E
T
O
N
L
Y
XX
XX
XX
GENERAL SYMBOLS
SHEET NUMBER
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
SECTION NUMBER
DETAIL NUMBER
DETAIL DESCRIPTION
ADDITIONAL DETAIL INFORMATION
SHEET NUMBER
AREA OF INCLUSION
00-000
2c 18 AWG
NUMBER OF CONDUCTORS
GAUGE OF WIRE
FILE NUMBER DESIGNATION
XXX-XXX-XX-XXX
FACILITY DESIGNATOR
LOCATION DISCIPLINE DESIGNATOR
DRAWING TYPE DESIGNATOR
3-4 DIGIT SEQUENTIAL PAGE NUMBER
0 - GENERAL (SYMBOLS LEGEND, NOTES, ETC.)
01 COVER SHEET
02 SYMBOLS PAGE
03 ABBREVIATIONS
04 DRAWING INDEX
05 EQUIPMENT LISTS
1 - PLANS (HORIZONTAL VIEWS)
10 - PLAN VIEWS
A. OVERALL PLAN VIEWS
B. SPECIFIC BUILDING PLAN VIEWS
C. ENLARGED PLAN VIEWS
11 - ELECTRICAL & CABLING
A. PLAN VIEWS SHOWING ELECTRICAL CONDUIT RUNS
B. PLAN VIEWS SHOWING FIBER OPTIC CONDUIT RUNS
C. JUNCTION BOX LOCATIONS
D. WIRE DETAILS OF SIZE, QUANTITY
2 - ELEVATIONS (VERTICAL VIEWS)
3 - SECTIONS (SECTIONAL VIEWS)
4 - LARGE-SCALE VIEWS
(PLANS, ELEVATIONS OR SECTIONS THAT ARE NOT DETAILS)
5 - DETAILS
6 - SCHEDULES AND DIAGRAMS
60 - BLOCK DIAGRAMS
61 - ONE-LINE DIAGRAMS
62 - EQUIPMENT INTERCONNECTION DIAGRAMS
63 - WIRING DIAGRAMS NOT SPECIFIC TO EQUIPMENT
64 - TELECOMMUNICATIONS DIAGRAMS
65 - EQUIPMENT SCHEDULES
66 - PROGRAMMING SCHEDULES
67 - RACEWAY/CIRCUIT SCHEDULES
DRAWING TYPE DESIGNATOR
(PER ERDC/ITL TR-06-X; TABLE 2-3)
NOTE: PAGE NUMBER IS AN ABBREVIATED VERSION OF THE FILE NUMBER
WIRE GAUGE DESIGNATION
XX-XXX
XX-XXX
XX-XXX
1. GENERAL NOTES ON THIS SHEET APPLY TO ALL DRAWINGS.
2. LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THE SET OF DRAWINGS. ADDITIONAL LEGENDS AND/OR OTHER LEGEND SHEETS MAY
APPEAR ON SPECIFIC DRAWINGS TO INDICATE SPECIFIC CONDITIONS.
3. NEWLY INSTALLED ENCLOSURES, CABINETS, HOUSINGS, BOXES AND FITTINGS HAVING HINGED
DOORS OR REMOVABLE COVERS AND WHICH CONTAIN CIRCUITS OR CONNECTIONS OF THE
ACS SYSTEM AND ITS POWER SUPPLIES, SHALL BE PROVIDED WITH COVER OPERATED,
CORROSION RESISTANT TAMPER SWITCHES, ARRANGED TO INITIATE AN ALARM SIGNAL
WHEN THE DOOR OR COVER IS MOVED. THE ENCLOSURE AND THE TAMPER SWITCH SHALL
FUNCTION TOGETHER AND SHALL NOT ALLOW DIRECT LINE OF SIGHT TO ANY INTERNAL
COMPONENTS BEFORE THE SWITCH ACTIVATES. TAMPER SWITCHES SHALL BE
INACCESSIBLE UNTIL THE SWITCH IS ACTIVATED; HAVE MOUNTING HARDWARE
CONCEALED SO THAT THE LOCATION OF THE SWITCH CANNOT BE OBSERVED FROM THE
EXTERIOR OF THE ENCLOSURE; BE CONNECTED TO CIRCUITS WHICH ARE UNDER
ELECTRICAL SUPERVISION AT ALL TIMES, IRRESPECTIVE OF THE PROTECTION MODE IN
WHICH THE CIRCUIT IS OPERATING; SHALL BE SPRING-LOADED AND HELD IN THE
CLOSED POSITION BY THE DOOR OR COVER; AND SHALL BE WIRED SO THAT THE
CIRCUIT IS BROKEN WHEN THE DOOR OR COVER IS DISTURBED.
4. ACCESS CONTROL SYSTEM EQUIPMENT MUST BE EQUIPPED WITH CONTINUOUSLY MONITORED
TAMPER DETECTION DEVICES REGARDLESS OF WHETHER THE SYSTEM IS IN THE ACCESS OR
SECURE MODE OF OPERATION. UPON DETECTION, AN ALARM (NOT FAULT) CONDITION MUST BE
TRANSMITTED TO THE PCU OR MONITORING STATION.
5. EXACT MOUNTING LOCATION OF ACS, DAS, CCTV SHALL BE VERIFIED PRIOR TO INSTALLATION.
6. ALL EXTERIOR HOUSING ENCLOSURE BOXES SHALL BE NEMA 4X RATED.
7. CONTRACTOR SHALL INSTALL A WARNING UNDERGROUND MARKER TAPE ABOVE ALL SECURITY
UNDERGROUND DUCTBANKS. IT SHALL BE SOLID FOIL MARKER TAPE, ORANGE, 3 INCHES WIDE, DETECTABLE, NON-DEGRADABLE, CORROSION RESISTANT, TEAR RESISTANT AND WITH
1 1/4 INCH STENCILED BLACK NON-DEGRADABLE LETTERS. WORDING ON MARKERS READ
"CAUTION DUCTBANK BURIED BELOW." TRACER WIRE SHALL BE INCLUDED WITH ALL DIRECTIONAL BORING.
8. ALL FIELD DISTRIBUTION BOXES AND SECURITY EQUIPMENT CABINETS SHALL HAVE A GROUNDING
LUG OR A GROUNDING BUS BAR INSTALLED.
9. ALL COPPER WIRE TERMINATIONS SHALL HAVE AT LEAST A 3'-0" (0.91m) SERVICE
LOOP AT EACH END. ALL ESS WIRING SHALL HAVE AT LEAST 3'-0" BETWEEN A SURGE
PROTECTOR AND A DEVICE.
10. IF ANY REQUIRED INFORMATION IS NOT CONTAINED WITHIN THIS SET OF DRAWINGS, REFER TO
MANUFACTURER SUPPLIED INSTRUCTIONS.
11. THESE DRAWINGS ARE DIAGRAMITC IN NATURE AND ARE NOT INTENDED TO SHOW EXACT CONDITIONS
AS MAY EXIST UNLESS NOTED OTHERWISE.
12. DO NOT SCALE DRAWINGS AS PROVIDED SCALES ARE FOR REFERENCE ONLY.
13. THE SCALES APPLIED TO THE DRAWINGS ARE BASED OFF U.S. CUSTOMARY UNITS STANDARD.
GENERAL NOTES
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
GENERAL INFORMATION
CODY FIELD OFFICE
BLM-CFO-01-102
01-102
SECTION - GENERAL
B
MCL
NOTE: ABBREVIATIONS LISTED ARE BASED ON INDUSTRY STANDARDS AND ALL MAY NOT BE APPLICABLE TO PROJECT.
ABBREVIATIONS SECURITY LEGEND
ALARM INTERFACE
CENTRAL PROCESSING UNIT
ELECTRONIC ENTRY CONTROL SYSTEM
HAND GEOMETRY UNIT
INTRUSION DETECTION SYSTEM
ACC/SEC
BMS
CJB
CPU
CR
ECE
EECS
HGU
IDS
DCM DOOR CONTROL MODULE
CARD READER
CU COPPER
EMT ELECTRICAL METALLIC TUBING
BALANCED MAGNETIC SWITCH
ENROLLMENT CENTER EQUIPMENT
H
DC DIRECT CURRENT
CTL CONTROL
AMP
ABOVE FINISHED FLOOR
AMPERE
EP EXPLOSION PROOF
AIF ACTIVE INFRARED SENSOR
DIB DEVICE INTERFACE BOX
CLOSED CIRCUIT TELEVISIONCCTV
CAMERA JUNCTION BOX
CTW CAMERA TOWER
DB
AFF
DP DISTRIBUTION POWER
AWG AMERICAN WIRE GAUGE
AUX
APPROX APPROXIMATELY
AUXILIARY
ADMIN ADMINISTRATOR
BLDG BUILDING
CAB
C
CABINET
COMM COMMUNICATION
DIST DISTANCE
ELECT ELECTRICAL
EQ EQUAL
EQUIP EQUIPMENT
ENCL ENCLOSURE
UNDERGROUND DUCTBANK
EHH ELECTRICAL HAND HOLE
HIGH
BAT BATTERY
BC BATTERY CHARGER
DVR DIGITAL VIDEO RECORDER
EMI ELECTROMAGNETIC INTERFERENCE
EMH
ELECTRICAL MANHOLE
CONDUIT
ERAC
BPS BYPASS SWITCH PANEL
ELEVATIONEL
FOP FIBER OPTIC DISTRIBUTION PANEL
FORX
FOT
FIBER OPTIC RECEIVER MODULE
FIBER OPTIC TRANSMISSION PANEL
GND GROUND
FDB FIELD DISTRIBUTION BOX
GALV GALVANIZED
GB GLASS BREAK
FOSC FIBER OPTIC SENSOR CABLE
(F) FUTURE
FO FIBER OPTIC
FOCC FIBER OPTIC I/O CONVERTER
GS GATE SENSOR SWITCH
GSB GATE SENSOR SWITCH JUNCTION BOX
FOB FIBER OPTIC BOX
FOSS FIBER OPTIC SENSOR SYSTEM
EXT EXTERIOR
EQUIPMENT RACK AIR CONDITIONER
FFOM FENCE FIBER OPTIC MODULE
FFOR FENCE FIBER OPTIC RACK
FOM FIBER OPTIC MODULE
FOPP FIBER OPTIC PATCH PANEL
FOR FIBER OPTIC RACK
I/O INPUT/OUTPUT
RIGID GALVANIZED STEEL
STAINLESS STEEL
RGS
SST
UPS
VM
REX
TSL TURNSTILE
SSC
TA
TAS
TROUBLE ALARM
T
TBD TO BE DETERMINED
REQ'D REQUIRED
SW SWITCH
TB TERMINAL BLOCK
W
VIDEO MONITOR
UNINTERRUPTIBLE POWER SUPPLY
TAMPER ALARM SWITCH
REQUEST TO EXIT DEVICE
V VOLTAGE
ST STRAIGHT TIP
SP SPARE
QTY QUANTITY
PR PAIR
WIDTH
PWS POWER SUPPLY ENCLOSURE
SSB SURGE SUPPRESSION BOX
TWF TAUT WIRE FENCE ALARM AREA
PP POWER PANEL
TRANSFORMER/TAMPER
UL
UNDERWRITERS LABORATORIES
TYP TYPICAL
WHT WHITE
W/ WITH
OH OVERHEAD
REC RECEIVING
SO FLEXIBLE POWER CORD
SQ SQUARE
SHH SECURITY HAND HOLE
VLS VEHICLE LOOP SENSOR
TV TELEVISION
THHN 90°, 600 VOLT NYLON JACKETED
BUILDING WIRE FOR DRY LOCATIONS
SS
SCMS SITE CONTROL AND MONITORING
SYSTEM
PNL PANEL
PTZ PAN TILT AND ZOOM
PVC POLYVINYL CHLORIDE
GATE SAFETY SENSOR
SURGE SUPPRESSOR-COAX
SSDA SURGE SUPPRESSOR-DATA
SSP SURGE SUPPRESSOR-POWER
SPDT SINGLE POLE DOUBLE THROW
SWGR SWITCHGEAR
WS WORK STATION
OSSC
PS POWER SUPPLY
SCH SCMS HUB
SCP
SCW
SCWC
SCMS PRINTER
SCMS WORKSTATION
SCMS WORKSTATION CONSOLE
LP
LOPA LOSS OF POWER ALARM
NTS NOT TO SCALE
NO
NC NORMALLY CLOSED
NORMALLY OPEN
lbs POUNDS
LED LIGHT EMITTING DIODE
LAN LOCAL AREA NETWORK
MSR MAIN SERVICE ROAD
NO. NUMBER
NOT IN CONTRACTNIC
KBD
KPD
CCTV KEYBOARD
KEYPAD
JUNCTION BOXJB
MLIB
MON
MATRIX LOOPING INPUT BAY
MECH MECHANICAL
MONITOR
CCTV ALARM INTERFACE UNITTVAI
CCTV CENTRAL PROCESSING UNITTVCP
LANU LOCAL AREA NETWORK UNIT
TP TELEPHONE DISTRIBUTION PANEL
LSI LEAD SYSTEM INTEGRATOR
SPP SECURITY POWER PANEL
VID VIDEO
LOCAL PROCESSOR
ON-SITE SUPPORT CENTER
SJB SECURITY JUNCTION BOX
HS HATCH SWITCH
HVR HIGH VOLTAGE RELAY
LCD LIQUID CRYSTAL DISPLAY
RECP RECEPTACLE
RTC REMOTE TERMINAL CONTROLLER
AS ALARM SOUNDER
ECU ELECTRIC CYLINDER UNLATCH
A:
B:
C:
D:
E:
F:
G:
H:
I:
J:
K:
L:
MBS MATRIX BAY SWITCH
M:
N:
O:
P:
Q:
R:
S:
T:
U:
V:
W:
TIC TELEPHONE INTERCOM
VAC VOLTAGE ALTERNATING CURRENT
VDC VOLTAGE DIRECT CURRENT
ITS INFRASTRUCTURE TAMPER SWITCH
ES ELECTRIC STRIKE
BMX BISTATIC MICROWAVE TRANSMITTER
BMR BISTATIC MICROWAVE RECEIVER
MS MAGNETIC SWITCH
SDR SECURITY DOOR/GATE
CAM CAMERA
OPR GATE OPERATOR
DT DUAL TECHNOLOGY MOTION SENSOR
DS DURESS SWITCH
HEAT DETECTORHD
PREX PUSH-ACTIVATED REQUEST TO EXIT
STR STROBE
HORNHRN
PB PUSH BUTTON
MAG ELECTROMAGNETIC LOCK
HWS HORN WITH STROBE
MIC MICROPHONE
FAK FIRE ALARM KEYPAD
SD SMOKE DETECTOR
PIR PASSIVE INFRARED
MM MONOSTATIC MICROWAVE
SM SINGLE MODE FIBER OPTIC
SEC SECURITY EQUIPMENT CABINET
WAP WIRELESS ACCESS POINT
CPL CAMERA POLE
CAS FIBER OPTIC CASSETTE
EX EXISTING
WDS WIRELESS DURESS SWITCH
AN ANNUNCIATOR
DPS DOOR POSITION SWITCH
ACCESS CONTROL MODULEACM
IR INFRARED
HPB HANDICAP PUSH BUTTON
INTERCOMINT
DAS DURESS ALARM SYSTEM
DPDT DOUBLE POLE DOUBLE THROW
ECB ELECTRIC CRASH BAR
EML ELECTRIC MORTISE LOCK
FOPC FIBER OPTIC PATCH CASSETTE
FIELD OF VIEW
FOTC
FOTX
FOV
FIBER OPTIC TRANSCEIVER MODULE
FIBER OPTIC TRANSMITTER MODULE
FEETFT
F CONTINUED:
GCM GENERAL CONTROL MODULE
INTERCOM MASTERINT/M
INTERMEDIATE METALLIC CONDUIT IMC
NVR NETWORK VIDEO RECORDER
SPST SINGLE POLE SINGLE THROW
FJB FIBER OPTIC JUNCTION BOX
HH HAND HOLE
MCB MECHANICAL CRASH BAR
MCL MECHANICAL CIPHER LOCK
PUSH BUTTON
CARD READER
CONTACTLESS CARD READER W/ KEYPAD
REQUEST TO EXIT
INTERCOM
ELECTRIC STRIKE
ELECTROMAGNETIC LOCK
ACCESS CONTROL PANEL
DURESS SYSTEM
EQUIPMENT GROUND
STROBE
POLE
NORTH ARROWS
UNINTERRUPTABLE POWER SUPPLY
ACS
FIXED CAMERA
DIGITAL 180° FIXED CAMERA
DIGITAL 270° FIXED CAMERA
WIRELESS ACCESS POINT
CCTV
IDS
ALARM KEYPAD
(ALARM INTERFACE)
DOOR POSITION SWITCH
WIDE GAP
DURESS SWITCH
CHAIN LINK FENCE
GENERAL SYMBOLS
DOOR POSITION SWITCH
ELECTRICALLY OPERATED CRASH BAR
REFERENCED NOTE
DETAIL REFERENCE
XX-XXX
UPS
ECB
MAG
K
N
BALANCED MAGNETIC SWITCH
UL LEVEL 2, HIGH SECURITYHS
BALANCED MAGNETIC SWITCH
ES
CONTACT/CONTACTLESS CARD READER W/ KEYPAD
K
C/CL
MECHANICAL CIPHER LOCK
W
180 DEGREE
270 DEGREE
D
360° FISH EYE CAMERA
ACP
DURESS
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
ABBREVIATIONS &
SECURITY LEGENDS
CODY FIELD OFFICE
BLM-CFO-01-103
01-103
SECTION - GENERAL
B
DRAWING INDEX
GENERAL SHEET #
BLM-CFO-01-101 COVER SHEET 01 OF 09
BLM-CFO-01-102 GENERAL INFORMATION 02 OF 09
BLM-CFO-01-103 ABBREVIATIONS AND SECURITY LEGENDS 03 OF 09
BLM-CFO-01-104 DRAWING INDEX 04 OF 09
BLM-CFO-01-105 EQUIPMENT LIST 05 OF 09
PLANS SHEET #
BLM-CFO-10-001 CODY FIELD OFFICE SITE REFERENCE PLAN 06 OF 09
BLM-CFO-10-002 CODY FIELD OFFICE SITE PLAN WITH CCTV FOV(S) 07 OF 09
BLM-CFO-10-101 CODY FIELD OFFICE FLOOR REFERENCE PLAN WITH DEVICE LOCATIONS 08 OF 09
BLM-CFO-10-102 CODY FIELD OFFICE GARAGE FLOOR REFERENCE PLAN WITH DEVICE LOCATIONS 09 OF 09
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
DRAWING INDEX
CODY FIELD OFFICE
BLM-CFO-01-104
01-104
SECTION - GENERAL
B
EQUIPMENT LIST
NOTE: EQUIPMENT LISTED REPRESENTS PRIMARY COMPONENTS ONLY AND IS NOT AN ALL INCLUSIVE LIST FOR A FULLY FUNCTIONING SYSTEM.
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
EQUIPMENT LIST
CODY FIELD OFFICE
BLM-CFO-01-105
01-105
SECTION - GENERAL
B
XXXXXXXXX
X X
X
X X
X X X
X X
X X
X X X
X X
X X
X X X
X X
X X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
SHED SHED
A1
10-101
FLOOR PLAN
A1
10-201
FLOOR PLAN
GARAGE
B L
A C
K B
U R
N
A
V E
P A
R K
I N
G
EXISTING
BUILDING
C O
F
E
F
I C
E
S I D
E W
A L
K
S I D
E W
A L
K
P A
R K
I N
G
S E
C U
R
P
A R
K I N
G
PARKING
EXISTING PERSONNEL
GATE
EXISTING MANUAL
VEHICLE GATE
EXISTING FENCE TYPICAL
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
CODY FIELD OFFICE
N
SITE REFERENCE PLAN
A1 SCALE: 1" = 30'
0'-0" 30'-0"
BLM-CFO-10-001
10-001
SECTION -PLANS
CODY FIELD OFFICE
SITE REFERENCE PLAN
B
XXXXXXXXX
X X
X
X X
X X X
X X
X X
X X X
X X
X X
X X X
X X
X X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
SHED SHED
A1
10-101
FLOOR PLAN
GARAGE
B L
A C
K B
U R
N
A
V E
P A
R K
I N
G
EXISTING
BUILDING
C O
E
F
I C
E
S I D
E W
A L
K
S I D
E W
A L
K
P A
R K
I N
G
S E
C U
R
P
A R
K I N
G
PARKING
EXISTING PERSONNEL
GATE
EXISTING MANUAL
VEHICLE GATE
EXISTING FENCE TYPICAL
A1
10-201
FLOOR PLAN
270 DEGREE
270 DEGREE270 DEGREE
270 DEGREE
270 DEGREE
CONTRACTOR TO INSTALL NEW TRENCH TO EXISTING
POLES AND TO THE SHED FOR NEW CAMERAS.
INSTALL A NEW 1" UNDERGROUND CONDUIT TO THE
EXISTING POLES AND NEW CAMERAS.
COVER TRENCH AND RE-ASPHALT . SEE DWG 10-201
180 DEGREE
180 DEGREE
INSTALL NEW 180 DEGREE CAMERA ON
EXISTING LIGHT POLE. SEE DWG 10-201
INSTALL NEW 270 DEGREE CAMERA ON
EXISTING SHED. SEE DWG 10-201
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
CODY FIELD OFFICECODY FIELD OFFICE
N
SITE PLAN W/ CCTVFOV(S)
A1 SCALE: 1" = 30'
0'-0" 30'-0"
BLM-CFO-10-002
10-002
SECTION -PLANS
CODY FIELD OFFICE
SITE PLAN WITH CCTV
FOV(S)
B
BREAK ROOM
LOCKER ROOM
WOMEN'S ROOM MEN'S ROOM
MANAGERS
OFFICE
OFFICE
MECH. ROOM
RANGER ROOM
LAN./ COMP./
PHONE ROOM
COPIER /
SUPPLY ROOM
CONFERENCE ROOM
RECEPT.
PUBLIC
R.R.
LOBBY
PUBLIC
CONFERENCE
ROOM
FILE ROOM
VESTIBULE
OPEN
OFFICE
OPEN
OFFICE
ECB
MAG
K
ES
K
C/CL
DOOR-101
K
ES
DOOR-103
DOOR-104
K
ES
DOOR-105
K
ES
DOOR-106
ES
DOOR-107
K
ES
K
ES
DOOR-108
HCP
HCP
ECB
K
CAM-101
CAM-102
DOOR-102
CAM-110
CAM-109 CAM-112
CAM-111
CAM-108
CAM-104
CAM-103
UPS
ACS
DURESS
NVR
WIRELESS
5 8
CAM-105
S
S
S
S
S
270 DEGREE
270 DEGREE
270 DEGREE270 DEGREE
FISH EYE
CAM-113
S
S
S
S
S
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
CODY FIELD OFFICE
N
CODY FIELD OFFICE
BLM-CFO-10-101
10-101
SECTION - PLANS
FLOOR PLAN W/ DEVICES
A1
SCALE: 1" = 10'
0'-0" 10'-0"
CODY FIELD OFFICE
FLOOR REFERENCE PLAN
WITH DEVICE LOCATIONS
K
CARD READER W/ KEYPAD
DOOR POSITION SWITCH
EQUIPMENT REFERENCE CHART
WIRING DETAILSSYMBOL
EQUIPMENT REFERENCE CHART
SSTROBE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
ACS
SEE DETAIL
ACCESS CONTROL SYSTEM
A1/53-101
DURESSDURESS SYSTEM
A1/52-103
UNINTERRUPTIBLE
POWER SUPPLY
UPS
NETWORK VIDEO RECORDER
NVR
E1/54-102
WIRELESS
DURESS WIRELESS RECEIVER
AND WIRELESS PUSHBUTTONS
D1/52-104
D4/52-104
CCTV MONITOR
HDMI
D1/51-105
TBD
SEE DETAIL
REQUEST TO EXIT
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
ES
ELECTRIC STRIKE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-108
NOTES:
EXACT MOUNTING LOCATIONS OF LOCAL PROCESSOR SHALL BE VERIFIED BY ONSITE
REPRESENTATIVE PRIOR TO INSTALLATION.
INSTALL HARD-WIRED DURESS SWITCH AT THE RECEPTIONIST COUNTER AND CONNECT IT
TO THE BOSCH B9512G. ACTIVATION OF THE DURESS SWITCH SHALL ANNUNCIATE
CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF OFFICES AND BREAK
ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR COMMUNICATION.
TWO WIRELESS DURESS SWITCHES SHALL BE PROVIDED AND INTEGRATED INTO THE
BOSCH B9512G THROUGH A WIRELESS RECEIVER. ACTIVATION OF THE DURESS SWITCH
SHALL ANNUNCIATE CONTRACTOR INSTALLED HORNS WITH STROBES IN THE STAFF
OFFICES AND BREAK ROOM, AND SHALL NOTIFY LOCAL AUTHORITIES THROUGH CELLULAR
COMMUNICATION. POWER FOR THE WIRELESS RECEIVER SHALL BE CONNECTED TO THE UPS.
INSTALL NEW CARD READER, REQUEST TO EXIT, DOOR POSITION SWITCH AND ELECTRIC STRIKE.
INSTALL NEW CARD READER AND INTEGRATE INTO NEW ACS SYSTEM.
CARD READER AT THIS DOOR SHALL BE A HID - RKCL40.
ALL EXTERIOR ACS DOORS SHALL ALSO BE EQUIPPED WITH DOOR CLOSER, LATCH
PROTECTOR AND SECURITY HINGES.
INSTALL MONITOR FOR CCTV SUPERVISION. EXACT LOCATION TO BE
DETERMINED BY AUTHORIZED ON-SITE PERSONNEL.
CONTRACTOR TO PROCURE AND INSTALL A NEW UPS THAT IS CAPABLE OF SUPPLYING
POWER TO THE ACCESS CONTROL SYSTEM, DURESS SYSTEM AND THE CCTV SYSTEM
FOR A MINIMUM OF 30 MINUTES.
INSTALL NEW NVR FOR NEW CCTV SYSTEM. NVR WILL BE RACK MOUNTED AND VERIFIED BY
ONSITE REPRESENTATIVE PRIOR TO INSTALLATION.
INSTALL NEW CLIENT COMPUTER WITH MONITOR FOR ACS. EXACT LOCATION TO BE
DETERMINED BY AUTHORIZED ON-SITE PERSONNEL.
INSTALL NEW INTERIOR 1MP CAMERA AND INTEGRATE INTO THE NEW CCTV SYSTEM.
INSTALL NEW EXTERIOR 270 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND INTEGRATE
INTO THE NEW CCTV SYSTEM.
EXISTING ELECTRIC CRASH BAR, REQUEST TO EXIT, HANDICAP PUSH BUTTON AND
ELECTROMAGNETIC LOCK TO BE INTEGRATED IN TO ASC SYSTEM.
INSTALL 360 DEGREE FISHEYE CAMERA AND INTEGRATE INTO NEW CCTV SYSTEM.
REMOVE EXISTING CYPHER LOCK.
HANDICAP PUSHBUTTONS TO BE TIED INTO NEW ACCESS CONTROL SYSTEM.
SYMBOL
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. ALL WIRING TO MEET MANUFACTURER SPECIFICATIONS. REPLACE WIRING AS NEEDED.
3. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-107
CLIENT WORKSTATION
WITH MONITOR
DURESS SWITCH
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/52-104
FIXED INTERIOR 1MP CAMERA CAT6 PLENUM A1/51-103
CAT6 PLENUM A1/51-101
270 DEGREE CAMERA
HIGH SECURITY
CARD READER W/ KEYPAD
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-106
K
C/CL
COMPONENT
A1/53-108
A4/52-104
D1/51-105
D4/54-103
FISH EYE
CAT6 PLENUM
360 DEGREE FISH EYE CAMERA
A1/51-104
270 DEGREE
B
MCL-201
K
ES
180 DEGREE
1" UNDERGROUND CONDUIT TO SHED
CAM-114
N
MARK DATE
SHEET OF
2 3 4 5 6 7
1 2 3 4 5 6 7
A
B
C
D
E
F
DESCRIPTION
A
B
C
D
E
F
DESIGN BY
PROJECT IDENTIFICATION
CONTRACT NUMBER:
CAD DWG FILE:
DRAWN BY:
DESIGNED / CHECKED BY:
DATE:
SHEET TITLE
THIS BOX 2" @ 24x36
CLIENTELE
THIS BOX 1" @ 11x17
L. MORGAN
K.E.
140L6220P0043
JULY 3, 2020
7-3-201
INTEGRATED SECURITY
SOLUTIONS, INC.
108 COOPERATIVE WAY
KALISPELL, MT 59901
PHONE: 406-755-2504
BUREAU OF LAND
MANAGEMENT
NATIONAL OPERATIONS
CENTER
BLM WYOMING
STATEWIDE SECURITY
SYSTEM DESIGN
BID SET
CODY FIELD OFFICE
BLM-CFO-10-201
10-201
SECTION - PLANS
N
CODY FIELD OFFICE
FLOOR PLAN W/ DEVICES
A1
CODY FIELD OFFICE
GARAGE FLOOR
REFERENCE PLAN WITH
DEVICE LOCATIONS
0'-0" 8'-0"
SCALE: 1/8" = 1'
EQUIPMENT REFERENCE CHART
WIRING DETAILSSYMBOL
EQUIPMENT REFERENCE CHART
COMPONENT
K
CARD READER W/ KEYPAD
DOOR POSITION SWITCH
6C 18 AWG STRANDED
SHIELDED PLENUM WIRE
A1/53-105
REQUEST TO EXIT
4C 18 AWG STRANDED
SHIELDED PLENUM WIRE
ES
ELECTRIC STRIKE
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-108
2C 18 AWG STRANDED
SHIELDED PLENUM WIRE
TBD/53-107
A1/53-108
CAT6 PLENUM
A1/51-101
180 DEGREE CAMERA
180 DEGREE
NOTES:
INSTALL NEW CARD READER, REQUEST TO EXIT, DOOR POSITION
SWITCH AND ELECTRIC STRIKE. ACCESS CONTROL EQUIPMENT WILL CONNECT TO THE
ACCESS CONTROL PANEL LOCATED IN THE MAIN OFFICE BUILDING VIA EXISTING
UNDERGROUND CONDUIT.
TRENCH FROM THE GARAGE TO THE EXISTING POLES AND TO THE SHED.
INSTALL A 1" CONDUIT IN THE TRENCH FOR THE (1) 180 DEGREE CAMERA THAT IS TO BE
MOUNTED ON THE EXISTING POLE AND THE (1) 270 DEGREE CAMERA THAT IS TO BE
MOUNTED ON THE SHED. BOTH CAMERAS ARE TO HAVE BUILT IN IR ILLUMINATORS. COVER
THE TRENCH AFTER INSTALLATION AND RE-ASPHALT OVER THE TRENCH.
INSTALL (1) NEW EXTERIOR 180 DEGREE CAMERA WITH BUILT IN IR ILLUMINATOR AND
INTEGRATE INTO THE NEW CCTV SYSTEM.
INSTALL A NEW 8 PORT POE SWITCH TO POWER THE CAMERAS. SWITCH WILL NEED TO
CONNECT TO THE SWITCH INSIDE THE MAIN OFFICE BUILDING VIA EXISTING
UNDERGROUND CONDUIT.
GENERAL EQUIPMENT NOTES:
1. ALL DEVICES SHOWN ARE NEW UNLESS NOTED OTHERWISE.
2. REFER TO DETAILS PACKAGE SHEET 50-101 FOR FURTHER INFORMATION ON EQUIPMENT.
B