This document is a set of architectural design specifications and drawings for the Wisdom Ranger Station Roof and Siding Replacement project located at the Beaverhead Deerlodge National Forest, Wisdom Ranger District in Beaverhead County, Montana, under the U.S. Department of Agriculture Forest Service, Northern Region.

The project encompasses roof and siding replacement work across four buildings: the Main Office, Fuel Storage Building, Men's Bunkhouse, and Women's Bunkhouse. Base items include mobilization, fuel storage building reroofing, men's bunkhouse reroofing, women's bunkhouse reroofing, men's bunkhouse residing, and women's bunkhouse residing. All work is to be contracted via Lump Sum Quotation (LSQ) method. Optional items include replacing windows at the men's bunkhouse, replacing windows at the women's bunkhouse, and replacing roof sheathing (32 each, Area quantity). Metal siding materials are government-furnished and do not include wall sheathing or house wrap. The specifications require removal and disposal of existing asphalt shingles and installation of new 26-gauge exposed fastener metal roofing panels in dark gray. Roofing details include R-13 insulation batt, structural wood panel sheathing, metal soffit and fascia, and new ridge vents and bathroom vent louvres. Window replacement work includes framing adjustments and interior refinishing where openings are resized. All trim, flashing, and utility protection during construction are contractor responsibilities, with structures requiring removal prior to roof installation to be communicated to the Contracting Officer before construction begins.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMOVE EXISITNG ASH PAL T SHINGLES.

INSTALL NEW 26 GAUGE EXPOSED

FASTENER ROOFING PANELS

12.5'

14.5' 12.5' 43.5'

CHIMNEY TO BE DEMOLISHED AND SHEATHED

FLUSH TO ROOF SURFACE.

EXISTING SEWER 12

VENT PIPE 6Q

TYP.

O> e �0.25'

NEW RIDGE VENT TO BE INSTALLED.

INSTALL NEW 4" BATHROOM

VENT LOUVRE

[I] tO

9.5'

30'

EXISTING GABLE VENT TO BE FRAMED

AND SHEATHED OVER

INSTALL NEW 4" BATHROOM

VENT LOUVRE

INTERIOR CHIMNEY STACK TO BE

REMOVED AND HOLE PATCHED

EXISTING ELECTRICAL--------..

BOXES

39.5' 43.5'

NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF UTILITIES DURING CONSTRUCTION.

2. ALL NECESSARY TRIM AND FLASHING SHALL BE INSTALLED AS PART OF THE ROOF AND SIDING

INSTALLATION.

3. METAL SIDING MATERIALS SHALL BE GOVERNMENT FURNISHED.

4. NEW WINDOWS MAY REQUIRE ADDITIONAL FRAMING WORK TO ENSURE NEW WINDOW SIZES FIT

CORRECTLY. WORK INCLUDES REFINISHING OF INTERIOR IF OPENING IS RESIZED.

5. INSTALLATION OF NEW WINDOWS IS AN OPTION ITEM AND NOT PART OF THE BASE AWARD.

6. ROOF SHALL BE DARK GRAY. CONTRACTOR SHALL SUBMIT COLOR TO CO FOR APPROVAL.

7. BATHROOM VENT LOUVRE INCLUDED INSTALLING NEW 30 FT 4" FLEXIBLE VENT PIPE FROM

BATHROOM FAN TO THE LOUVRE. LOCATION TO BE DESIGNATED BY CO.

United States Department of Agriculture Forest Service

NORTHERN REGION

WISDOM ROOF & SIDING REPLACEMENTS

BEAVERHEAD DEERLODGE NATIONAL FOREST

WISDOM RANGER DISTRICT

O>

DRAWING TITLE

IT]

REMOVE AND DISPOSE OF

EXISTING TONGUE AND

GROOVE SIDING. INSTALL

NEW SHEATHING AND SIDING

AS SHOWN ON SHEET 7.

REMOVE EXISTING

SOFFIT AND FASCIA.

INSTALL NEW METAL

SOFFIT AND FASCIA.

WINDOW SCHEDULE

WINDOW LABEL EXISTING DIMENSIONS NEW DIMENSIONS

A 55" X 24" 48" X 24"

B 55" X 36"' 53.25" X 35.75"

C 39.5" X 19.5" 46.25" X 21"

D 40" X 40" 48" X 48"

D ATE DESIGNER CHECKED

I 21912s JCAT I MMCABE

MEN'S BUNKHOUSE

NO. REVISION DESCRIPTION BY DATE

If':, TYPE OF WINDOW

CASEMENT

SINGLE HUNG

HOPPER

SLIDING WINDOW

DWG SHEET NO. SHEET

5 OF

REMOVE EXISITNG ASH PAL T SHINGLES.

INSTALL NEW 26 GAUGE EXPOSED

FASTENER ROOFING PANELS

12.5' 14.5' 12.5'

43.5'

EXISTING SEWER VENT PIPE

TYP.

O>

NEW RIDGE VENT TO BE INSTALLED.

EXISTING ELECTRICAL

BOXES

NOTES:

BJ

39.5'

1. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF UTILITIES DURING

CONSTRUCTION.

2. ALL NECESSARY TRIM AND FLASHING SHALL BE INSTALLED AS PART OF THE ROOF AND

SIDING INSTALLATION.

EXISTING GABLE VENT TO BE FRAMED

AND SHEATHED OVER

INSTALL NEW 4" BATHROOM

VENT LOUVRE

REMOVE AND DISPOSE OF

EXISTING TONGUE AND

GROOVE SIDING. INSTALL

NEW SHEATHING AND SIDING

AS SHOWN ON SHEET 7.

C

9.5' 30'

CT]

INSTALL NEW 4" BATHROOM

VENT LOUVRE

REMOVE EXISTING

SOFFIT AND FASCIA.

INSTALL NEW METAL

SOFFIT AND FASCIA.

3. METAL SIDING MATERIAL SHALL BE GOVERNMENT FURNISHED. WINDOW SCHEDULE

4. NEW WINDOWS MAY REQUIRE ADDITIONAL FRAMING WORK TO ENSURE NEW WINDOW SIZES

FIT CORRECTLY. WORK INCLUDES REFINISHING OF INTERIOR IF OPENING IS RESIZED.

5. INSTALLATION OF NEW WINDOWS IS AN OPTION ITEM AND NOT PART OF THE BASE AWARD.

6. ROOF SHALL BE DARK GRAY. CONTRACTOR SHALL SUBMIT COLOR TO CO FOR APPROVAL.

7. BATHROOM VENT LOUVRE INCLUDED INSTALLING NEW 30 FT 4" FLEXIBLE VENT PIPE FROM

BATHROOM FAN TO THE LOUVRE. LOCATION TO BE DESIGNATED BY CO.

BEAVERHEAD DEERLODGE NATIONAL FOREST

WISDOM RANGER DISTRICT

WINDOW LABEL

A

B

C

D

WOMEN'S BUNKHOUSE

EXISTING DIMENSIONS NEW DIMENSIONS

55"" X 24"" 48" X 24"

°0

X 36"" 53.25"" X 35. 75"

39.5'" X 19.5" 46.25" X 21"

40" X 40" 48" X48"

DATE DESIGNER CHECKED

1r·

JCAT MMCABE

REVISION DESCRIPTION BY

TYPE OF WINDOW

CASEMENT

SINGLE HUNG

HOPPER

SLIDING WINDOW

DWG SHEET NO. SHEET

DATE

6 OF