This document is a combined synopsis/solicitation for a Wire and Cable Blanket Purchase Agreement (BPA) for the Air Force Test Center (AFTC) at Edwards Air Force Base, CA. The solicitation is seeking quotes from small businesses for a wide range of wire and cable products including hook-up wire, coaxial cable, twinaxial/triaxial cable, shielded cable, Category cable, thermocouple wire, and fiber optic cable. The contract period of performance is anticipated to be 5 years. The solicitation is a 100% small business set-aside under NAICS code 331420. Evaluation factors include technical capability, price, quality/accuracy, lead time, and pricing. Quotes are due by 3:00pm PDT on August 9, 2024. The solicitation provides detailed specifications and a pricing template for the required products. No substitutions are allowed, and all products must be orange jacketed, UV laser markable, and provided in minimum 500 ft lengths.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment FA930224Q00170001 SF 30.pdf | ||
| Amendment 1 for FA930224Q0017 Questions and Answers.docx | DOCX document | |
| Solicitation - FA930224Q0017.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| LINE | ITEM DESCRITPTION | JACKET COLOR | 1,000 ft ($/ft) | 2,500 ft ($/ft) | 5,000 ft ($/ft) | 10000 ($/ft) | 15,000 ft ($/ft) | 20,000 ft ($/ft) | MANUFACTURER |
| HOOK UP WIRE (Silver coated copper) | |||||||||
| 1 | MIL-W-22759/43-2-3 | SAE AS22759/43-2-3 | ORANGE | |||||||
| 2 | MIL-W-22759/43-6-3 | SAE AS22759/43-6-3 | ORANGE | |||||||
| 3 | MIL-W-22759/43-8-3 | SAE AS22759/43-8-3 | ORANGE | |||||||
| 4 | MIL-W-22759/44-12-3 | SAE AS22759/44-12-3 | ORANGE | |||||||
| 5 | MIL-W-22759/44-12-4 | SAE AS22759/44-12-4 | YELLOW | |||||||
| 6 | MIL-W-22759/44-12-9 | SAE AS22759/44-12-9 | WHITE | |||||||
| 7 | MIL-W-22759/44-12-0 | SAE AS22759/44-12-0 | BLACK | |||||||
| 8 | MIL-W-22759/44-16-3 | SAE AS22759/44-16-3 | ORANGE | |||||||
| 9 | MIL-W-22759/44-16-4 | SAE AS22759/44-16-4 | YELLOW | |||||||
| 10 | MIL-W-22759/44-16-9 | SAE AS22759/44-16-9 | WHITE | |||||||
| 11 | MIL-W-22759/44-16-0 | SAE AS22759/44-16-0 | BLACK | |||||||
| 12 | MIL-W-22759/44-20-3 | SAE AS22759/44-20-3 | ORANGE | |||||||
| 13 | MIL-W-22759/44-20-4 | SAE AS22759/44-20-4 | YELLOW | |||||||
| 14 | MIL-W-22759/44-20-9 | SAE AS22759/44-20-9 | WHITE | |||||||
| 15 | MIL-W-22759/44-20-0 | SAE AS22759/44-20-0 | BLACK | |||||||
| 16 | MIL-W-22759/44-22-3 | SAE AS22759/44-22-3 | ORANGE | |||||||
| 17 | MIL-W-22759/44-22-4 | SAE AS22759/44-22-4 | YELLOW | |||||||
| 18 | MIL-W-22759/44-22-9 | SAE AS22759/44-22-9 | WHITE | |||||||
| 19 | MIL-W-22759/44-22-0 | SAE AS22759/44-22-0 | BLACK | |||||||
| 20 | MIL-W-22759/44-24-3 | SAE AS22759/44-24-3 | ORANGE | |||||||
| 21 | MIL-W-22759/44-24-4 | SAE AS22759/44-24-4 | YELLOW | |||||||
| 22 | MIL-W-22759/44-24-9 | SAE AS22759/44-24-9 | WHITE | |||||||
| 23 | MIL-W-22759/44-24-0 | SAE AS22759/44-24-0 | BLACK | |||||||
| COAXIAL CABLE | |||||||||
| 24 | M17/060-RG142 ORANGE XL-ETFE JACKET | ORANGE | |||||||
| 25 | M17/128-RG400 ORANGE PFP JACKET | ORANGE | |||||||
| 26 | M17/94-RG179 ORANGE XL-ETFE JACKET | ORANGE | |||||||
| 27 | M17/113-RG316 ORANGE TEFZEL JKT | ORANGE | |||||||
| 28 | M17/110-RG302 FEP ORANGE JACKET | ORANGE | |||||||
| 29 | LMR-400UF, RF Coax Cable or equivalent, Inner stranded bare copper conductor, dielectric Foam Polyethylene, inner Aluminum Foil poly tape with tinned copper braid outer shield, TPE –thermoplastic elastomer (orange preferred, black alternate) minimum segment length of 250' if not purchased by the foot. | ORANGE | |||||||
| 30 | LMR-600UF, RF Coax Cable or equivalent, Inner stranded bare copper conductor, dielectric Foam Polyethylene, inner Aluminum Foil poly tape with tinned copper braid outer shield, TPE –thermoplastic elastomer (orange preferred, black alternate) minimum segment length of 250' if not purchased by the foot. | ORANGE | |||||||
| 31 | LL335i Low Loss Flexible Coax Cable or equivalent. DC to 18 GHz at 50 Ohms Impedance. Orange jacket, special order? | ORANGE | |||||||
| TWINAXIAL/TRIAXIAL CABLE | |||||||||
| 32 | CABLE, RADIO FREQUENCY, FLEXIBLE, TWIN, M17/176-00002 ORG XL-ETFE JKT 77 OHM | ORANGE | |||||||
| 33 | W-6107-2774 (WHITMORE/WIREMETICS) or equivalent. 26 ga, High Strength Plated Alloy, 2 Cond, Twisted pair per M17 for balanced line of 120 OHM +/- 12, Shielded 90% Minimum coverage (aluminized foil tape – facing out, and Silver plated copper braid), Orange Extruded FEP Jacket (or acceptable equivalent jacket material). minimum segment length of 250' if not purchased by the foot. | ORANGE | |||||||
| 34 | CABLE, RADIO FREQUENCY, FLEXIBLE, TRIAXIAL, 95 OHMS, M17/178-00001 ORG BRAIDED JACKET | ORANGE | |||||||
| SHIELDED CABLE (Silver coated copper) | |||||||||
| 35 | M27500-8SP1S23 8 GA, 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 (OPTIONAL) | ORANGE | |||||||
| 36 | M27500-12SR1S23 12 AWG 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 | ORANGE | |||||||
| 37 | M27500-12SR2S23 12 AWG 2 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0 | ORANGE | |||||||
| 38 | M27500-12SR3S23 12 AWG 3 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2 | ORANGE | |||||||
| 39 | M27500-12SR4S23 12 AWG 4 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5 | ORANGE | |||||||
| 40 | M27500-16SR1S23 16 AWG 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 | ORANGE | |||||||
| 41 | M27500-16SR2S23 16 AWG 2 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0 | ORANGE | |||||||
| 42 | M27500-16SR3S23 16 AWG 3 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2 | ORANGE | |||||||
| 43 | M27500-16SR4S23 16 AWG 4 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5 | ORANGE | |||||||
| 44 | M27500-20SR1S23 20 AWG 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 | ORANGE | |||||||
| 45 | M27500-20SR2S23 20 AWG 2 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0 | ORANGE | |||||||
| 46 | M27500-20SR3S23 20 AWG 3 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2 | ORANGE | |||||||
| 47 | M27500-20SR4S23 20 AWG 4 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5 | ORANGE | |||||||
| 48 | M27500-20SR6S23 20 AWG 6 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5+3+6 | ORANGE | |||||||
| 49 | M27500-22SR1S23 22 AWG 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 | ORANGE | |||||||
| 50 | M27500-22SR2S23 22 AWG 2 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0 | ORANGE | |||||||
| 51 | M27500-22SR3S23 22 AWG 3 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2 | ORANGE | |||||||
| 52 | M27500-22SR4S23 22 AWG 4 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5 | ORANGE | |||||||
| 53 | M27500-22SR6S23 22 AWG 6 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5+3+6 | ORANGE | |||||||
| 54 | M27500-24SR1S23 24 AWG 1 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9 | ORANGE | |||||||
| 55 | M27500-24SR2S23 24 AWG 2 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0 | ORANGE | |||||||
| 56 | M27500-24SR3S23 24 AWG 3 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2 | ORANGE | |||||||
| 57 | M27500-24SR4S23 24 AWG 4 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5 | ORANGE | |||||||
| 58 | M27500-24SR6S23 24 AWG 6 COND SHIELDED, ORG. XL-ETFE JKT., INNER COLOR CODE 9+0+2+5+3+6 | ORANGE | |||||||
| CAT CABLE | |||||||||
| 59 | AS6070/6-2A3UA ORANGE EXTRUDED FEP, PTFE OR TEFZEL JACKET. 24 AWG SILVER PLATED COPPER ALLOY CABLE 4 TWISTED PAIRS WITH SPLINE TO PREVENT CROSSTALK. Cable shall have a silver plated braided copper shield with 95% minimum coverage. PAIR COLORS: WHT/BLUE WITH BLUE; WHT/ORG WITH ORANGE; WHITE/GREEN WITH GREEN; WHITE/BROWN WITH BROWN. Each individual conductor shall be constructed of 19 Strand/36 AWG CONDUCTORS. Minimum segment length of 250'. UV Laser Markable. | ORANGE | |||||||
| 60 | AS6070/1-0A3U ORANGE EXTRUDED FEP, PTFE OR TEFZEL JACKET. 24 AWG SILVER PLATED COPPER ALLOY 4 CONDUCTOR CABLE. This cable is equivalent to NF24Q100-01 from Carlisle Interconnect Technologies. It is also known as Quadrex cable, 100 Base-T Ethernet cable and has also been called CAT3 cable and telephone cable. Minimum segment length of 250'. UV Laser Markable. | ORANGE | |||||||
| THERMOCOUPLE WIRE | |||||||||
| 61 | Thermocouple Wire, K type 20 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| 62 | Thermocouple Wire, K type 22 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| 63 | Thermocouple Wire, K type 24 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| 64 | Thermocouple Wire, J type 20 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| 65 | Thermocouple Wire, J type 22 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| 66 | Thermocouple Wire, J type 24 AWG Strained, Twisted, Shielded with orange insulated jacket, 500° F Minimum, UV Laser Markable. | ORANGE | |||||||
| FIBER OPTIC CABLE | |||||||||
| 67 | C25964 FlightGuide Simplex 1.8 mm Multimode 50/125 OM3 Fiber Cptic Cable, Orange XL-ETFE Outer Jacket. UV Laser Markable. (OPTIONAL) | ORANGE |
| REQUIREMENTS |
| 1. ALL WIRE AND CABLES WILL BE ORANGE OUTER JACKET, UNLESS OTHERWISE SPECIFIED. |
| 2. ORANGE JACKET / INSUATION COLOR WILL NOT BE ACHIEVED USING AN ORANGE INK TO PAINT (STRIPE) THE JACKET. |
| 3. ALL WIRE AND CABLES WILL BE UV LASER MARKABLE. UV LASER MARKING TEXT MUST BE LEGIBLE. |
| 4. ALL WIRE AND CABLES WILL BE 500 FT MINIMUM SEGMENT LENGTHS UNLESS OTHERWISE SPECIFIED. |
| 5. THE WIRE AND CABLE MUST BE PACKAGED WITH ONLY 1 CONTINUOUS LENGTH PER REEL/SPOOL. |
| 6. SOLID COLORS WILL BE USED IN ACCORDANCE WITH MIL SPEC 681-TABLE 1, COLOR CODE: 0=BLACK; 1=BROWN; 2=RED; 3=ORANGE; 4=YELLOW; 5=GREEN; 6=BLUE; 7=VIOLET 8=GREY, 9=WHITE. |
| 7. ALL WIRE AND CABLES WILL BE MEASURED IN FEET. |
| 8. WARO = WEEKS AFTER RECEIVED ORDER. |
| 9. MANUFACTURER TEST REPORTS AND MATERIAL CERTIFICATION DOCUMENTS REQUIRED WITH EACH SHIPMENT |
| 10. DISTRIBUTOR TO INCLUDE NAME(S) OF WIRE AND CABLE MANUFACTURERS FOR EACH ITEM QUOTED WITH PROPOSAL / QUOTATION |
| 11. NO SUBSTITUTIONS. |