West_Perimeter_Bridge__DSH-P_-_OSFM_Approved_Drawings.pdf
PDF 10 MB Posted
- Attached to
- 26-30612-000 - West Perimeter Bridge
- Solicitation number
- 0000040329
- Issued by
- California
About this file
This is a set of Office of the State Fire Marshal-approved construction drawings for the West Perimeter Bridge replacement project at the Department of State Hospitals (DSH) Patton facility located in Patton, California. The project scope includes replacement of the existing concrete vehicle bridge over a drainage channel, installation of ADA-compliant warning curbs, removal and relocation of existing water lines, demolition of the existing bridge structure and associated site elements, and reconstruction of pavement with approach transitions on both sides of the bridge to achieve proposed grades. The drawings are prepared by J.C. Chang & Associates, Inc., with structural engineering by David Pomerleau (License No. C41062) and civil engineering leadership by Kaveh Lavasany. The project documentation consists of 18 sheets including title sheets, fire access plans, civil plans with erosion control, demolition and new work plans, grading plans, and structural details. The contract is under JCCA Project Number 24794-3 with an Office of the State Fire Marshal approval number of 25-4109, dated December 4, 2025. The drawings reflect 100 percent design submittal status as of April 29, 2025, with the Fire and Panic only approval notation indicating final approval is subject to field inspection.
The project design is based on a 32-kip concentrated vehicle axle load for the bridge with an allowable soil bearing pressure of 1,500 pounds per square foot. The structural design concrete compressive strength is 4,000 PSI for the bridge slab and is governed by the 2022 California Building Code and applicable CBC standards. Contractor responsibilities include verification of all existing underground utilities through ground penetrating radar and utility locating services within approximately 20 feet of all new work, protection of existing trees with temporary fencing and tree protection zones, adherence to all soil compaction requirements at 90-95 percent relative compaction per ASTM D1557, and coordination of all utility shutdowns with facility operations using at least 72 hours' notice with shutdowns not exceeding 4 hours. Special inspections and testing requirements include continuous observation of fill placement compaction, periodic inspection of reinforcement placement, post-installed anchor inspection in hardened concrete, and concrete strength verification prior to slab completion. The project requires the contractor to submit a construction phasing plan, product and materials submittals, and as-built drawings upon completion, with all work performed in accordance with prevailing wage requirements and compliance with OSHA safety regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P A T T O
N A
V E
WEBSTER DRIVE
MILLER
CS-77-CS-79
GB-14
M B-
P
HIGHLAND AVE.
GB-16
S-13
U
GB-15
G-259
C
IR
C L E D
R
G-258
J
S-1
RILEY ST
S-6
GB-10
CS-8
R
CS-5
O L
IV
E S
T
O L
IV
E S
T
S-7
CS-70
S-2 S-3
CS-72
S-5
CS-44 -
CS-54 -
CS-71
PATTON
CEMETERY
DATE STREET
MB-30D
G2
R-2
GB-7
GB-18
MB-70A
HIGHLAND
FIRE
DEPT.
294 272
MB-30A
518516 524 525
R-10
R-6
GB-17
R-1
CD
CS-73
MB-ND
G-15
R-15
R-14 G-13
R-13
R-8 G-8
G-19
R-19
G-17 R-18
MB-70F
MB-70B
MB-70C
GB-4
GB-1
GB-13
GB-9
565564
R-11
521 519
R-12
MB-NC
MB-NA
MB-EBB
MB-OA
MB-U
MB-70E
MB-70D
CORP
YARD
S-1
PUMALO AVE.
S-1
LA
KEVIEW CIRCLE
S-
CIRCLE
DRIVE
M Y R
T L E
D R
EMERALD LANE
C E N
T R
A L
A V E
TA
LL
M
AN
R
OAD
V
IC
T O
R
IA
A V E
GERICKE
FIELD
GB-12
GB-11
TENNIS
COURT
R-17
MB-O
B
REC
FIELD
GB-6
O R
A N
G E S
T R
E E T
GB-5
GB-3
GB-8
GB-10
R-16
G-16
MB-30C
MB-30B
M
IR
T L E D
R
G-260
O
N 235
T
P
297H
CS-9
CS-10
CS-6
CS-7
S-8
MB-EBC
CS-1
MB-NB
CS-4
S-4
CS-11-CS-43
CS-47 -
CS-53
GB-2
CS-75
CS-74
MB-EBA
G
CS-46
CS-3
M
ED BERNATH 243
CS-76
S-9
LANE
S-14
SOLAR
ARRAY
R E A R S
E R V
IC
E
R O A D
T0.1
TITLE SHEET
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H -P
\C A D \2
T .1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
3102 EAST HIGHLAND AVENUE, PATTON, CALIFORNIA 92369
DEPARTMENT OF STATE HOSPITALS - PATTON
DEPARTMENT OF STATE HOSPITALS
WEST PERIMETER BRIDGE
PROJECT DIRECTORY
PREPARED FOR:
PATTON STATE HOSPITAL
3102 EAST HIGHLAND AVE
PATTON, CALIFORNIA 92369
DEPARTMENT OF STATE HOSPITALS
1215 O ST, 2ND FLOOR
SACRAMENTO, CALIFORNIA 95814
RICARDO REILOVA
CONTRACT MANAGER
PHONE : (559) 920-8668
EMAIL:
RICARDO.REILOVA@DSH.CA.GOV
RAMON DE HARO
SUPERVISOR OF BUILDING TRADES
3102 EAST HIGHLAND AVE
PATTON, CALIFORNIA 92369
PHONE: (909) 672-1717
FAX: (909) 425-7064
EMAIL: RAMON.DEHARO@DSH.CA.GOV
PREPARED BY:
J.C. CHANG & ASSOCIATES, INC.
ENGINEERS, ARCHITECTS AND PLANNERS
385 VAN NESS AVENUE, SUITE 208
TORRANCE, CALIFORNIA 90501
PHONE : (310) 212-7644
CIVIL ENGINEER PROJECT LEAD
KAVEH LAVASANY
385 VAN NESS AVE. #208
TORRANCE, CALIFORNIA 90501
CIVIL ENGINEER OF RECORD
JAMES REDMOND
LIC. NO. C41062
385 VAN NESS AVE. #208
TORRANCE, CALIFORNIA 90501
STRUCTURAL ENGINEER OF RECORD
DAVID POMERLEAU
DPOMERLEAU@BUEHLERENGINEERING.COM
GENERAL
T0.1 TITLE SHEET
T0.2 FIRE ACCESS SITE PLAN
T0.3 STATE FIRE MARSHAL TRIAGE LIST
T0.4 BUILDING INFORMATION
CIVIL
C0.1 CIVIL COVER SHEET
C0.2 OVERALL SITE PLAN
C0.3 EROSION CONTROL PLAN
C1.1 DEMOLITION PLAN
C2.1 NEW WORK PLAN
C3.1 GRADING PLAN
C8.1 DETAILS
C8.2 DETAILS
STRUCTURAL
S1.1 GENERAL NOTES
S1.2 GENERAL NOTES
S1.3 STRUCTURAL SPECIAL INSPECTIONS & TESTING
S2.1 PARTIAL SITE PLAN
S5.1 TYPICAL CONCRETE DETAILS
S5.2 DETAILS
APPLICABLE CODES AND STANDARDS
1. 2022 BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.
2. 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.
(2021 INTERNATIONAL BUILDING CODE & 2021 CALIFORNIA AMENDMENTS)
3. 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.
(2020 NATIONAL ELECTRICAL CODE AND 2021 CALIFORNIA AMENDMENTS)
4. 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.
(2021 UNIFORM MECHANICAL CODE AND 2021 CALIFORNIA AMENDMENTS)
5. 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.
(2021 UNIFORM PLUMBING CODE AND 2021 CALIFORNIA AMENDMENTS)
6. 2022 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.
7. 2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.
(2021 INTERNATIONAL FIRE CODE AND 2021 CALIFORNIA AMENDMENTS)
8. 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11,
TITLE 24 C.C.R.
9. 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R.
10. TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS.
PROJECT'S MAJOR MILESTONES:
A. SUBMIT CONSTRUCTION PHASING PLAN TO PROJECT MANAGER.
B. PRODUCT/MATERIALS SUBMITTALS.
C. PROJECT MOBILIZATION
D. INSTALL TEMPORARY EROSION CONTROL AND K-RAIL BARRICADES, AND
PERFORM DEMOLITION.
E. GRADE THE SITE TO NEW GRADES AND ELEVATIONS SHOWN TO
ACCOMMODATE THE REVISED BRIDGE LAYOUT.
F. CONSTRUCT THE REST OF SCOPE OF WORK, INCLUDING CONCRETE PAVING,
CONCRETE BRIDGE SPAN, AND CONCRETE CURB.
PROJECT MILESTONES
N
SCOPE OF WORK VICINITY MAP SITE PLAN
PATTON
STATE
HOSPITAL
V
IC
T O
R
IA
A V E N
U E
C E N
T R
A L A
V E N
U E
P A L M
A V E N
U E
BASE LINE STREET
E HIGHLAND AVENUE
PROJECT LOCATION
DRAWING INDEX
CIVIL SCOPE:
1. REPLACEMENT OF THE WEST PERIMETER VEHICLE BRIDGE
2. ADD WARNING CURBS AS SHOWN ON DRAWINGS.
3. REMOVE WATER LINE AS SHOWN ON DRAWINGS.
4. REPLACEMENT OF PAVEMENT ON EITHER SIDE OF THE PERIMETER BRIDGE
FOR TRANSITIONING GRADES.
PROJECT SITE
V
IC
T O
R
IA
A V E
HIGHLAND AVE.
UTILITY SHUTDOWNS
1. UTILITY SHUTDOWNS SHALL NOT EXTEND BEYOND 4 HOURS.
2. ALL UTILITY SHUTDOWNS MUST BE COORDINATED WITH FACILITY
OPERATIONS WITH AT LEAST 72 HOURS NOTICE.
N
TOTAL NUMBER OF SHEETS: 18
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-4109
M-30D
541 543
532 544
CS-77
CS-79
506531 281
H-297
CD
H-278 509
GB-17
291536 R-2
289 290
GB-1
R-1
M-30B M-30C 505
N235
M-NA
M-NB
M-NC
M-ND
540 554
294 272
M-30A
573 CS-74
GB-10
575578
GB-4
G-2
GB-5
G-259
G-258
G-260
S-7
S-6
CS-5
ED BERNARTH
GB-9
S-3
S-9
S-10
S-11
S-12
S-4
GB-3
GB-2
GB-8
S-13
GB-6
1 1
SIGN 1 SIGN 1
SIGN 2
1 SIGN 1 &
SIGN 2
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
T .2
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
SCALE: N 0 20010 FEET100
1" = 100'
FIRE ACCESS SITE PLAN
T0.2
FIRE ACCESS SITE PLAN
LEGEND:
(E) FIRE HYDRANT
FIRE APPARATUS ROUTE
PROJECT LOCATION
EXISTING PAVED ROAD
SEE NOTES ON THIS SHEET
FOR CODE ANALYSIS
HIGHLAND AVENUE
V
IC
T O
R
IA
A V E N
U E
DATE STREET
M Y R
T L E D
R
TURNING RADIUS = 34'
P A T T O
N A
V E
SITE ACCESS FROM PUBLIC
RIGHT OF WAY AND USING
EXISTING PAVED ROADS
TURNING RADIUS = 100'
NOTES:
1. PER SAN BERNARDINO COUNTY FIRE
PREVENTION STANDARD A-1 AND CALIFORNIA
FIRE CODE APPENDIX D, ACCESS ROADS
SERVING FIRE APPARATUS TRAFFIC TRAVEL
ARE TO BE 20' MINIMUM FOR ONE-WAY
TRAFFIC OR 26' MINIMUM FOR TWO-WAY
TRAFFIC. THE FIRE APPARATUS ROUTE SHOWN
ON THIS SITE PLAN MEETS THESE
REQUIREMENTS.
2. THE BRIDGE AND ROADWAY INFRASTRUCTURE
BEING IMPROVED WITHIN THIS PROJECT IS
STRICTLY INTENDED FOR HOSPITAL POLICE
PATROL VEHICLES.
3. DUE TO THE EXISTING CONDITIONS OF THE
PATROL ROADWAY'S INSUFFICIENT WIDTH,
LOCATION ON THE PROPERTY, AND
TOPOGRAPHY OF THIS AREA, THIS PATROL
ROADWAY IS NOT INTENDED FOR FIRE
APPARATUS VEHICLE ACCESS.
EXISTING PAVED ROAD
SEE NOTES ON THIS SHEET
FOR CODE ANALYSIS
TURNING RADIUS = 42'
TURNING RADIUS = 52'
TURNING RADIUS = 48'
NEW WORK PLAN KEYNOTES:
ROADWAY ACCESS SIGNAGE. PER DETAIL ON THIS SHEET.1
ROADWAY ACCESS SIGNAGE1
T0.2 NOT TO SCALE
TURNING RADIUS = 28'
TURNING RADIUS = 20'
SITE ACCESS FROM PUBLIC
RIGHT OF WAY AND USING
EXISTING PAVED ROADS
TURNING RADIUS = 34'
18" DIA.
EXISITNG
GRADE
2" DIAM. GALV. IRON SIGN POST
M
IN
RIGID STREET SIGN
MAKE: ALUMINUM (40 MIL)
SIZE: 10"x14" - LETTERS 0.48"
TEXT CONTENT: SEE ABOVE (SIGN 1
AND SIGN 2) AND SITE PLAN FOR
WHERE EACH SIGN IS APPLICABLE.
FASTEN SIGN WITH (2) 1/4" DIAM.
STAINLESS STEEL CARRIAGE BOLTS
W/ WASHERS TO GALVANIZED STEEL
POST (MANGLE THREADS AFTER
INSTALLATION).
RESTRICTED ACCESS
AREA
SIGN 2SIGN 1
UNAUTHORIZED VEHICLES
NOT ALLOWED BEYOND
THIS POINT
CONCRETE FOOTING
WEIGHT LIMIT
15 TONS PER AXLE
30 TONS GROSS
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
T0.3
STATE FIRE MARSHAL
TRIAGE LIST
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D S H
-P \C
A D
\2 T .3
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
LOCAL FIRE AUTHORITY - ACCESS APPROVAL
ITEM
SUBMITTAL REQUIREMENTS SUBMITTAL RESPONSE REFERENCE
GENERAL
SEE FOR SPECIFIC SECTION COMMENTS NOT APPLICABLE
PROVIDE A COMPLETE PLAN REVIEW APPLICATION
SUBMIT PLANS SUFFICIENT SIZE
PROVIDE SITE ADDRESS
PROVIDE NAME OF OWNER AND OCCUPANT
IDENTIFY IF NEW CONSTRUCTION OR T.I
IDENTIFY IF NEW OR EXISTING TENANT SPACE
IDENTIFY IF DEFERRED SUBMITTAL
ADD OSFM FILE NUMBER TO TITLE SHEET
PROJECT IS A PHASED SUBMITTAL
SLIP SHEETS SHALL BE BOUND TO SET
SHEET INDEX
WET STAMP AND SIGN SHEETS
SCOPE OF WORK
PROVIDE A KEY PLAN COORDINATED TO EACH SHEET
PROVIDE A NORTH ORIENTED SITE MAP
ORIENTATE ALL SHEETS TO NORTH
PROVIDE ADOPTED CODE CYCLE LISTINGS AND STANDARDS
PROVIDE A LEGIBLE SCALE. TYPICALLY 1/8"
PROVIDE APPROVED REFERENCE PLANS/DOCUMENTATION
PROVIDED WITH SUBMITTAL
SITE PLAN SHOWN TO APPROPRIATE SCALE.
3102 EAST HIGHLAND AVENUE, PATTON, CA 92369
OWNER: DEPARTMENT OF STATE HOSPITAL
T.I.
NOT APPLICABLE
ALL RELEVANT
SHEETS
NOT APPLICABLE
T0.1
T0.1
OSFM NO IS NOTED ON THE TITLE SHEET T0.1
PROJECT IS NOT PHASED
NOT APPLICABLE
SHEET INDEX IS ON T0.1 T0.1
ELECTRONIC SIGNATURE PROVIDED ON DOCUMENT ALL SHEETS
SCOPE OF WORK IS INCLUDED ON TITLE SHEET T0.1
SITE KEY PLAN IS PROVIDED
NORTH ORIENTED SITE PLAN IS PROVIDED T0.2
SITE PLAN IS ORIENTED TO NORTH
ALL RELEVANT
SHEETS
ADOPTED CODE CYCLE LISTINGS ARE INCLUDED ON TITLE SHEET
NOT APPLICABLE
NOT APPLICABLE
T0.1
ITEM SUBMITTAL REQUIREMENTS SUBMITTAL RESPONSE REFERENCE
ACCESS AND WATER SUPPLY
PROVIDE LOCAL FIRE AUTHORITY APPROVAL LETTER
FIRE DEPARTMENT ACCESS
FIRE DEPARTMENT CONNECTION
FIRE HYDRANTS
FIRE ALARM ANNUNCIATOR
FIRE ALARM CONTROL PANEL
KNOX BOX/KEY SWITCH
ALL RELEVANT
SHEETS
OCCUPANT: DEPARTMENT OF STATE HOSPITAL
PROVIDED ON FIRE ACCESS SITE PLAN
T0.3
NOT APPLICABLE
NOT APPLICABLE
T0.3
PROVIDED ON FIRE ACCESS SITE PLAN
NOT AVAILABLE - USE FIRE HYDRANTS
NOT AVAILABLE
T0.3SEE ATTACHED LETTER
ELEVATOR GURNEY ACCOMODATION NOT APPLICABLE - NO ELEVATOR ACCESS TO ROOF -
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
M-30D
SCALE:
BUILDING INFORMATION
N0 20 1 FEET10
1" = 10'
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
T .4
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
BUILDING INFORMATION
BUILDING
NAME
CONSTRUCTION
TYPE
ACTUAL NUMBER OF
STORIES / (STORIES
ALLOWED CBC 504.4)
ACTUAL
BUILDING AREA
(AREA ALLOWED
CBC 506.2 )
SEPARATED /
NONE SEPARATED
SPRINKLER
COVERAGE
FIRE ALARM
OTHER
PROTECTION
SYSTEM
SMOKE
CONTROL
SYSTEM
OCCUPANT
LOAD
YEAR BUILDING
CONSTRUCTED
SEISMIC
JOINT
OCCUPANCY
CLASS
(E) GUARD POST 5
BUILDING
HEIGHT
EMERGENCY
RESPONDER
RADIO
COVERAGE
HIGH FIRE
HAZARD
SEVERITY
ZONE
T0.4
BUILDING INFORMATION
U II-B 1/2 +/-12' 80sf (8,500sf) NONE SEPARATED NONE NONE NONE NONE 1 NO NO NO2000
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
C0.1
COVER SHEET
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D S H
-P \C
A D
\2 C .1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
NOTES ABBREVIATIONS
LEGEND
1. GENERAL
1.1. PROVIDE TRENCH PLATES OVER ALL OPEN TRENCHES AT THE END
OF EACH WORK DAY. THE AMOUNT OF OPEN TRENCH WILL BE KEPT
TO A MINIMUM.
1.2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON
THE JOB AND REPORT ANY DISCREPANCIES TO THE ENGINEER
BEFORE PROCEEDING WITH THE WORK.
1.3. NO DEVIATIONS FROM THE DRAWING WITHOUT THE WRITTEN
APPROVAL OF THE ENGINEER. APPROVAL BY THE DSH INSPECTOR
DOES NOT CONSTITUTE AUTHORITY TO DEVIATE FROM PLANS OR
SPECIFICATIONS.
1.4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING THE
MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES AND
APPROPRIATE SAFETY PRECAUTIONS REQUIRED TO PERFORM THE
WORK.
1.5. DESIGN SOIL PRESSURE IS BASED ON SANDY CLAY , COMPACT WITH
AN ALLOWABLE BEARING PRESSURE OF 1,500 PSF.
1.6. PROVIDE DELINEATORS TO DIVERT PEDESTRIAN TRAFFIC.
2. STANDARDS
2.1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST
EDITION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS
CONSTRUCTION "GREENBOOK".
2.2. WHERE NO SPECIFIC DETAIL IS PROVIDED, THE CONSTRUCTION
SHALL BE IN ACCORDANCE WITH THAT INDICATED FOR SIMILAR
CONSTRUCTION ON THE PROJECT.
3. EXISTING UNDERGROUND UTILITIES
3.1. THE EXISTING CONDITIONS OF BELOW GROUND PIPING AND UTILITIES
SUCH AS GAS MAINS, WATER MAINS, SANITARY SEWERS, POWER AND
COMMUNICATIONS CONDUITS AND OTHER UTILITIES ARE TAKEN FROM
EXISTING RECORD DRAWINGS AND VERIFIED BY FIELD OBSERVATION.
THE LOCATION OF THESE UTILITIES IS APPROXIMATE ONLY. IT SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE EXACT
LOCATION AND DEPTH OF BELOW GROUND PIPING AND UTILITIES IN THE
IMMEDIATE VICINITY OF SUBSURFACE WORK, WHETHER SHOWN ON
THE DRAWINGS OR NOT. CONTRACTOR SHALL RETAIN THE SERVICES
OF AN UNDERGROUND UTILITY LOCATING COMPANY. UTILIZE GROUND
PENETRATING RADAR AND OTHER UTILITY LOCATING DEVICES TO
DETERMINE THE LOCATION AND DEPTH OF ALL UNDERGROUND
IMPROVEMENTS WITHIN APPROXIMATELY 20' OF ALL NEW WORK. PAINT
MARK ALL UTILITY LOCATIONS ON THE PAVEMENT SURFACE. THIS TASK
SHALL BE COMPLETED PRIOR TO ANY EXCAVATING.
3.2. PRIOR TO STARTING TRENCHING, POTHOLE TO VERIFY THE DEPTH
OF EXISTING PIPES WHICH ARE TO JOIN OR CROSS NEW PIPING OR
CONDUITS.ADJUST DEPTH OF NEW PIPE CONDUIT AS REQUIRED TO
CROSS EXISTING UTILITIES. NOTIFY ENGINEER OF ANY
DISCREPANCIES OR INTERFERENCES PRIOR TO LAYING ANY PIPE.
3.3. PRIOR TO STARTING TRENCHING, VERIFY LOCATION AND WORKING
CONDITION OF THE ASSOCIATED WATER VALVES WHICH NEED TO BE
EXERCISED DUE TO THE WATER SHUTDOWN ASSOCIATED WITH THE
SCOPE OF WORK. NOTIFY ENGINEER IF THERE ARE ANY
DISCREPANCIES WITH THE VALVES.
4. UTILITY OUT OF SERVICE
4.1. EXISTING UTILITIES SHALL NOT BE REMOVED FROM SERVICE
WITHOUT THE PRIOR WRITTEN CONSENT OF DSH. SUBMIT THE OUT
OF SERVICE REQUEST IN WRITING, DETAILING THE TIME AND
DURATION.
5. IRRIGATION
5.1. PRIOR TO DEMOLITION, CONTRACTOR IS RESPONSIBLE FOR
DOCUMENTING AND BRINGING ANY BROKEN OR DAMAGED
IRRIGATION COMPONENTS TO THE ATTENTION OF OWNER'S
REPRESENTATIVE.
5.2. EXISTING TURF, PLANTING AND TREES ARE SERVED BY SPRINKLER
SYSTEMS. SPRINKLER SYSTEM PIPING & VALVES ARE NOT SHOWN ON
THE DRAWINGS. IF IRRIGATION IS DISRUPTED, CONTRACTOR SHALL
HAND WATER ALL AFFECTED TURF, PLANTING AND TREES WHICH
REMAIN UNTIL IRRIGATION IS REESTABLISHED.
5.3. CONTRACTOR IS RESPONSIBLE FOR REPAIR OR REPLACEMENT OF
ANY IRRIGATION COMPONENTS WHICH ARE DAMAGED DURING
PROJECT.
5.4. THESE COMPONENTS INCLUDE BUT ARE NOT LIMITED TO MAIN LINES,
LATERAL LINES, VALVES, CONTROL WIRING, SLEEVING, SPRAY
HEADS, AND CONTROLLERS.
5.5. ALL COMPONENTS SHALL BE REPLACED WITH LIKE FOR LIKE
5.6. IF DUE TO PROJECT SOW, RE-ROUTING OR RECONFIGURATION OF
IRRIGATION SYSTEM IS NECESSARY TO ENSURE CONTINUITY AND
COVERAGE:
5.7. CONTRACTOR SHALL BE RESPONSIBLE FOR NECESSARY REDESIGN
IN CONSULTATION WITH DSH-LANDSCAPE DEPARTMENT
REPRESENTATIVE.
MINIMUM
MAXIMUM
MIN.
MAX.
FOOT (FEET)
FINISH (ED)
FT.
FIN.
EQUAL
EACH
DIAMETER
EQ.
EA.
DIA.
CHILLED WATER RETURN
CHILLED WATER SUPPLY
CHWR
CHWS
AGGREGATEAGG.
(E) EXISTING
EDGE OF GUTTEREG
EDGE OF PAVINGEP
FLOW LINEFL
GRADE BREAKGB
GROUND SURFACEGS
FINISH SURFACE ELEVATIONFS
DEMOLISH/REMOVE(D)
AND&
DIAMETER
CENTERLINE
AT
SQUARE
SPECIFICATION
SIMILAR
SQ.
SPEC.
SIM.
REQUIRED
OPENING
OUTSIDE DIAMETER
ON CENTER
NOMINAL
REQ'D.
OPNG.
O.D.
O.C.
NOM.
NUMBER
NOT IN CONTRACT
No.
N.I.C.
W/ WITH
TYP.
U.N.O.
T.O.C.
T.O.G.
THK. THICK (NESS)
TOP OF CONCRETE
UNLESS NOTED OTHERWISE
TOP OF GRADE
TYPICAL
N.T.S. NOT TO SCALE
TC TOP OF CURB
TW TOP OF WALL
Ø
DEPARTMENT OF STATE HOSPITALSDSH
CONCRETE
CLEAR
CONC.
CLR.
CONDENSER WATER RETURN
CONDENSER WATER SUPPLY
CWR
CWS
FINISHED GRADEFG
FINISHED FLOORFF
NATURAL GASG
FUEL OILF
SYNTHETIC NATURAL GASSNG
STORM DRAINSD
SANITARY SEWERSS
STEAM TUNNEL/LINEST
APPROXIMATEAPPROX.
CAST IRONCI
ENGINEER OF RECORDEOR
FINISH SURFACE RAMPFSR
(N) NEW
EXISTING/PROTECT IN PLACE KEYNOTE
DEMOLITION KEYNOTE
NEW WORK KEYNOTE
TOP AND TOE LANDSCAPE SLOPE
CONCRETE PAVING
ASPHALT PAVING
FIRE HYDRANT
AGGREGATE SURFACE
WATER VALVE
PIPE CAP
5.8. CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE RE-DESIGN
(INCLUDING ANY CHANGES IN LATERALS, VALVES, SPRAY HEADS,
ETC.) WILL WORK AS DESIGNED WITH EXISTING PRESSURES AND
SUPPLY LINES ON SITE.
5.9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION
OF ANY NECESSARY SLEEVES OF SUFFICIENT SIZE UNDER ALL
PAVED AREAS PRIOR TO PAVING.
5.10. ALL WIRES FROM CONTROLLER TO AUTOMATIC VALVES TO BE
COPPER, DIRECT BURIAL, MIN. #14 GAUGE. INSTALL IN SAME TRENCH
AS MAINLINE PIPING WHERE POSSIBLE. MIN. COVERAGE OVER WIRE
TO BE 18". COMMON WIRE TO BE WHITE IN COLOR.
5.11. PROVIDE MIN. 18" COVERAGE OVER ALL PRESSURE LINES, AND A
MIN. OF 12" COVERAGE OVER ALL NON-PRESSURE LINES. ALL
PIPING UNDER PAVING TO BE MIN. SCHEDULE 40 P.V.C. AND TO
HAVE MIN. 24" COVER OVER PIPING.
5.12. CONTRACTOR TO FLUSH ALL LINES AND ADJUST ALL SPRINKLERS
FOR MAXIMUM PERFORMANCE, AND TO PREVENT OVERSPRAY ONTO
WALKS, DRIVES, BUILDINGS AS MUCH AS POSSIBLE. THIS SHALL
INCLUDE SELECTING THE BEST DEGREE OF ARC TO FIT ACTUAL SITE
CONDITIONS.
5.13. NO NEW SPRAY HEADS/OVERHEAD IRRIGATION SHALL BE INSTALLED
WITHIN 24" OF ANY NON PERMEABLE SURFACE.
5.14. CONTRACTOR WILL INSTALL SWING CHECK VALVES OR SPRING
LOADED CHECK VALVES AS REQUIRED TO ELIMINATE EXCESSIVE
DRAINAGE FROM LOW SPRINKLERS.
5.15. UPON COMPLETION, CONTRACTOR TO SUPPLY TO OWNER,
COMPLETE SET OF REPRODUCIBLE "AS-BUILT" DRAWINGS.
DRAWINGS WILL SHOW LOCATION OF ALL VALVES, LINES, HEADS,
ETC. WITHIN LIMIT OF WORK.
5.16. THE IRRIGATION REPAIRS AND MODIFICATIONS SHALL BE FULLY
GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF
ACCEPTANCE BY OWNER. ANY DEFECTIVE MATERIALS OR POOR
WORKMANSHIP SHALL BE REPLACED OR CORRECTED BY
CONTRACTOR AT NO COST TO OWNER.
6. TREE PROTECTION NOTES
"TREE PROTECTION ZONE" (TPZ) FOR EXISTING TREES:
6.1. BEFORE BEGINNING ANY DEMOLITION OR CONSTRUCTION
OPERATIONS, THE CONTRACTOR SHALL INSTALL A CORRECTIONS
GRADE TEMPORARY FENCE AROUND ALL EXISTING TREES TO BE
SAVED WITHIN PROJECT AREA.
6.2. TPZ FOR ALL TREE SPECIES (EXCEPT PROTECTED TREES): THE
FENCE SHALL BE INSTALLED NO CLOSER THAN THE DRIP-LINE (OR AS
FAR AWAY FROM THE TRUNK AS PRACTICABLE).
6.3. TPZ FOR ALL PROTECTED TREES: THE FENCE SHALL BE INSTALLED
NO CLOSER TO THE TREE THAN 5' FROM THE EDGE OF THE TREE'S
DRIPLINE OR 15' FEET FROM THE TRUNK, WHICH EVER IS GREATER.
6.4. 5" THICK LAYER OF MULCH SHALL BE PLACED AROUND THE ENTIRE
DRIPZONE WITHIN THE TPZ, BEGINNING 1' FROM THE TRUNK.
6.5. NO CONTRACTORS OR CREWS SHALL BE ALLOWED INSIDE THIS TPZ.
6.6. NO FOREIGN MATERIALS (OTHER THAN MULCH PLACED PER D
ABOVE) SHALL BE STORED OR DUMPED WITHIN THIS AREA.
6.7. NO WORK OF ANY KIND, INCLUDING TRENCHING, SHALL BE ALLOWED
WITHIN THE TPZ EXCEPT WITH PRIOR APPROVAL OF ENGINEER OR
AUTHORIZED REPRESENTATIVE AND AS DESCRIBED IN TRENCHING
NOTES.
6.8. NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTIVE FENCING
INCLUDING DURING FENCE INSTALLATION AND REMOVAL.
6.9. TPZ FENCING SHALL BE CORRECTIONS GRADE AND APPROVED AS
SAFE FOR USE IN THE SECURED TREATMENT AREA BY DSH PRIOR TO
CONSTRUCTION.
6.10. TPZ FENCING SHALL REMAIN AROUND EACH TREE TO BE SAVED
UNTIL THE COMPLETION OF CONSTRUCTION OPERATIONS. IT SHALL
THEN BE REMOVED BY THE CONTRACTOR.
7. TRENCHING AND GRADING
7.1. ALL GRADING SHALL CONFORM TO CHAPTER 19A AND APPENDIX J OF
THE CURRENT EDITION OF THE CALIFORNIA BUILDING CODE
7.2. EXCESS EARTHWORK SHALL BE REMOVED FROM DSH PROPERTY
AND LEGALLY DISPOSED OF.
7.3. ALL DEMOLISHED ITEMS INCLUDING PAVING SHALL BE REMOVED FROM
DSH PROPERTY AND LEGALLY DISPOSED OF.
7.4. PIPE INSTALLATION SHALL WITH THE SPECIFICATIONS ALSO COMPLY
WITH THE MANUFACTURER'S RECOMMENDATIONS. REFER TO NOTES
IN SECTION 9 REGARDING HORIZONTAL DIRECTIONAL BORING
INSTALLATION.
7.5. ROCKS OR CLODS GREATER THAN 1½" INCHES IN ANY DIMENSION
SHALL NOT BE PERMITTED IN BACKFILL WITHIN 12 INCHES OF PIPE
OR APPURTENANCES.
7.6. BACKFILL SHALL BE COMPACTED TO 90% OF MAXIMUM DENSITY IN 8 INCH
LIFTS.
7.7. OWNER SHALL EMPLOY THE SERVICES OF AN APPROVED SOILS TESTING
COMPANY TO TEST THE COMPACTION OF THE BACKFILL. A MINIMUM OF 2
TESTS PER LIFT FOR EACH 2,000 SQUARE YARDS OF BACKFILL PLACED PER
DAY.
7.8. CONTRACTOR TO PROVIDE BARRICADES, SHORING, TRENCH PLATING ETC,
AS REQUIRED TO MAINTAIN A SAFE JOB SITE. COMPLY WITH ALL OSHA
REQUIREMENTS. SITE SHALL REMAIN OPERATIONAL DURING
CONSTRUCTION. MAINTAIN PEDESTRIAN WALKWAYS AND VEHICULAR
ACCESS FOR DSH PERSONNEL.
7.9. PROVIDE SHORING AS REQUIRED TO STABILIZE SIDES OF EXCAVATIONS.
SHORING MUST BE PROVIDED FOR EXCAVATIONS DEEPER THAN 5' WHERE
WORKERS ARE PRESENT.
7.10. CONTRACTOR SHALL HAND-DIG WITHIN THREE (3) FEET OF ALL EXISTING
UNDERGROUND UTILITIES.
7.11. TRENCHING SHALL FOLLOW A PATH TO AVOID EXISTING TREES (AND THEIR
DRIPLINES/ROOT SYSTEMS) WHENEVER POSSIBLE. WHERE THIS IS NOT POSSIBLE,
CONTRACTOR MUST BRING TO ATTENTION OF ENGINEER, OR AUTHORIZED
REPRESENTATIVE AND RECEIVE APPROVAL TO HAND DIG OR BORE.
7.12. RESTORE ALL SURFACES TO MATCH EXISTING CONDITIONS PRIOR TO THE START OF
WORK.
8. SUBMITTALS
8.1. SCONTRACTOR TO TAKE PHOTOS OF ALL AREAS, INCLUDING LANDSCAPING,
PRIOR TO DEMOLITION/CONSTRUCTION. PHOTOS SHALL BE SUBMITTED TO
EOR AND DSH.
8.2. CONTRACTOR SHALL SUBMIT A MINIMUM OF 5 COPIES OF ALL SUBMITTALS FOR
APPROVAL PRIOR TO PURCHASE OF MATERIALS. TWO COPIES WILL BE
RETAINED BY DSH. AN APPROVED COPY OF ALL SUBMITTALS MUST BE
MAINTAINED AT THE JOBSITE BY THE CONTRACTOR.
8.3. A SUBMITTAL IS REQUIRED FOR ALL EQUIPMENT AND MATERIAL INCLUDING,
PAINT, BEDDING MATERIAL, CONCRETE, ASPHALT CONCRETE, AGGREGATE
BASE, PIPING, VALVES, PULL BOXES, ETC.
8.4. SUBMIT TEST RESULTS SIGNED BY RESPONSIBLE TESTING AGENCY
WITHIN 2 WORKING DAYS OF COMPLETION FOR ALL REQUIRED TESTS.
8.5. CONTRACTOR SHALL MAINTAIN AN "AS-BUILT" SET OF DRAWINGS ON THE
JOB DURING THE COURSE OF THE WORK. RED MARK ALL CHANGES IN
LAYOUT, ELEVATION OF NEW AND EXISTING UNDERGROUND UTILITIES,
ETC. ON THE DRAWINGS AS THE WORK PROGRESSES. SUBMIT
RED-MARKED SET TO DSH AT THECOMPLETION OF THE JOB.
9. CLEAN UP
9.1. CONTRACTOR SHALL MAINTAIN CLEAN ROADWAYS, WALKWAYS, PARKING
LOTS, AREA OF WORK AND STAGING AREA AT ALL TIMES.
9.2. DAILY, AND UPON COMPLETION OF WORK, CONTRACTOR SHALL REMOVE
DEBRIS, RUBBISH AND WASTE FROM AREA OF WORK AND STAGING AREA.
9.3. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING PORTABLE TOILETS.
10. SEQUENCE OF WORK
10.1. SUBMIT TRAFFIC CONTROL PLAN FOR APPROVAL BY DSH PROJECT
MANAGER PRIOR TO STARTING ANY WORK. ENSURE ALL AREAS OF THIS
HOME ARE ACCESSIBLE TO BOTH PEDESTRIAN AND VEHICULAR TRAFFIC AT
ALL TIMES.
10.2. CONTRACTOR TO SCHEDULE AND PHASE DEMOLITION, NEW AND
CONSTRUCTION WORK WITH OWNER PRIOR TO PERFORM SCOPE OF WORK.
DETAIL #
SHEET #
DETAIL
POINT OF CONNECTION
POINT OF DISCONNECTION
TREE
EXISTING FENCE
ABBREVIATIONS
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
M-30D
M-30B M-30C
C0.2
OVERALL SITE PLAN
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C .2
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
OVERALL SITE PLAN
N
SCALE: 0 80FEET40
1" = 40'
OVERALL SITE PLAN
N
SCALE: 0 80FEET40
1" = 40'
PROJECT SITE
BASIS OF HORIZONTAL CONTROL:
THE BASIS OF HORIZONTAL CONTROL SHALL BE
BASED UPON DIMENSIONS AND STATIONS SHOWN
ON THE PLANS TO EXISTING IMPROVEMENTS AND
FEATURES OF THE SITE.
V
IC
T O
R
IA
A V E
PROPERTY LINE
FENCING
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
(E
(E
(W
(W
(W
(W
(E
M-30D
TC-1
TC-2
WM-3 WM-8
SE-1 OR AS REQUIRED SE-6
SE-1 OR AS REQUIREDSE-1A
TC-2
SE-6OR
AS REQUIRED
SE-1
C0.3
EROSION CONTROL PLAN
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C
.3
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
SCALE:
EROSION CONTROL PLAN
N 0 201 FEET10
1" = 10'
TEMPORARY SEDIMENT CONTROL:
SILT FENCE
PERIMETER SILT FENCE
GRAVEL BAG BARRIER
STOCKPILE MANAGEMENT
CONCRETE WASTE MANAGEMENT
WASTE MANAGEMENT &
MATERIAL POLLUTION CONTROL:
EQUIPMENT TRACKING CONTROL:
STABILIZED CONSTRUCTION ENTRANCE/EXIT
K-RAIL BARRIER, UTILIZE EXISTING K-RAIL BARRIERS WHERE
POSSIBLE
1. CONTRACTOR SHALL REMOVE ALL EROSION &
SEDIMENT CONTROL AND BEST MANAGEMENT
PRACTICE (BMP) FEATURES AT THE END OF THE
CONSTRUCTION.
GENERAL NOTES:
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
(E
(E
(W
(W
(W
(W
(W
(W) (W)
(E
TYP.
TYP.
16.75'
47.5
.5
M-30D
C1.1
DEMOLITION PLAN
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C
.1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
SCALE:
DEMOLITION PLAN
N 0 201 FEET10
1" = 10'
PROTECT IN PLACE KEYNOTES:
(E) CONCRETE PAVING
(E) CONCRETE CHANNEL
(E) CHAINLINK FENCE AND POST, INCLUDING FENCE FOOTING
(E) LANDSCAPE
(E) BUILDING
(E) TREE. SEE DETAIL FOR TREE PROTECTION ZONE.
(E) PULLBOX
(E) LIGHT POST
(E) WATER METER
(E) ELECTRICAL PANEL
(E) ELECTRICAL CONDUIT
(E) WATER LINE
(E) TRENCH
(E) EXPOSED CONCRETE FOR FENCE FOOTING
DEMOLITION KEYNOTES:
SAWCUT AND REMOVE CONCRETE PAVING
SAWCUT AND REMOVE CONCRETE CURB
CONCRETE BRIDGE PAVING
REMOVE WATER LINE. CAP LINES ON BOTH ENDS.
REMOVE PIPE SUPPORTS ATTACHED TO BRIDGE
C8.1
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
(E
(E
(W
(W) (W)
(E
16'
12'9 .2
R= 28'
.5
.5
.5
.5
1.75'
10.75'
M-30D
2'
2'
.5
.5
'5
TYP.
6 TYP.
7 TYP.
7 TYP.
FINISH
START
8 CASE 1
CASE 2
C2.1
NEW WORK PLAN
SCALE:
NEW WORK PLAN
N 0 201 FEET10
1" = 10'
NEW WORK PLAN KEYNOTES:
C8.1
C8.1
CONCRETE PAVING
6" CONCRETE CURB
STRUCTURAL CONCRETE PAVING. SEE STRUCTURAL SHEET S5.2
12" CONCRETE CURB. SEE STRUCTURAL SHEET S5.2
VARIABLE HEIGHT CONCRETE CURB
CONTRACTION JOINT
DOWELED CONSTRUCTION JOINT
EXPANSION JOINT
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C .1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
GENERAL NOTES:
1. RESTORE EXISTING IRRIGATION SYSTEM TO MATCH
OPERATION PRIOR TO START OF CONSTRUCTION, SEE
LANDSCAPE NOTES ON C0.1.
2. CONTRACTOR TO TAKE PHOTOS OF ALL AREAS, INCLUDING
LANDSCAPING, PRIOR TO DEMOLITION/CONSTRUCTION
3. SEE C0.1 FOR UTILITY LOCATE NOTES.
C8.2 5
C8.2
C8.2
C8.1
C8.2
CASE 1: BETWEEN EXIST. SECURITY FENCE STRIP FOOTING
AND NEW CONCRETE PAVING
CASE 2: BETWEEN EXIST. DRAINAGE CHANNEL AND NEW
CONCRETE PAVING
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
X X
X X
X X
X X
X X
X X
X X
X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
(E
(E
(W
(W
(W
(W
(W
(W) (W)
(E
(199.53) FS
(199.13) FS
(196.62) FS(196.21) FS
198.35 FS
(197.56) CULVERT TW
198.57 FS
(197.78) CULVERT TW
198.15 FS
(197.15) CULVERT TW
200.00 WM
TBM
M-30D
(2 .9
(2.5%)
199.22 TC
198.72 FS
199.65 TC
198.65 FS
199.28 TC
198.28 FS
0.7%
.5
198.91 FS
197.26 TC
196.76 FS
197.71 FS
1.2%
.4
.6
199.25 FS
2.
2%
0.
4%
1.3%
.5
.9
198.41 TC
197.41 FS
199.26 TC
198.26 FS
197.57 FS
(196.57) CULVERT TW
198.76 TC
197.91 TC
C3.1
GRADING PLAN
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C .1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
SCALE:
GRADING PLAN
N0 20 1 FEET10
1" = 10'
GRADING NOTES:
1. CONTRACTOR SHALL VERIFY IMPORT/EXPORT OF SOIL
WITH DSH REPRESENTATIVE AT A MINIMUM 3 DAYS
BEFORE MOBILIZATION. EXCESS EARTHWORK SHALL BE
REMOVED FROM DSH PROPERTY AND LEGALLY
DISPOSED OF, UNLESS OTHERWISE NOTIFIED.
BASIS OF HORIZONTAL CONTROL:
THE BASIS OF HORIZONTAL CONTROL SHALL BE BASED UPON
DIMENSIONS AND STATIONS SHOWN ON THE PLANS TO
EXISTING IMPROVEMENTS AND FEATURES OF THE SITE.
BASIS OF VERTICAL CONTROL:
THE BASIS OF VERTICAL CONTROL TO BE TEMPORARY
BENCHMARK (TBM) LOCATED AT THE PULLBOX DIRECTLY IN
FRONT OF GUARDPOST 5 AS SHOWN BY KEYNOTE
ELEVATION 200.00'.
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
C8.1
DETAILS
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D S H
-P \C
A D
\2 C .1
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
VEHICULAR CONCRETE PAVING
C8.1
NOT TO SCALE
CONCRETE CURB DETAIL
C8.1
NOT TO SCALE
TREE PROTECTION ZONE DETAIL
C8.1
NOT TO SCALE
NOT TO EXCEED 20' O.C.
PROVIDE CONTRACTION JOINT
NOTE:
8"
6"
SLOPE
C8.1
CRUSHED
AGGREGATE BASE
COMPACTED TO
95%
CONC PAVING
1/4"R
EXISTING FINISH GRADE
C
O V E R
SUBGRADE SOIL
COMPACTED TO AT LEAST
95% RELATIVE
COMPACTION PER ASTM
D1557.
PORTLAND CEMENT CONCRETE
SHALL HAVE A MIN. COMPRESSIVE
STRENGTH OF 4,500 PSI AT 28 DAYS
#4 REBAR @
MAXIMUM 24"
O.C. EACH WAY
CLASS 2 OR CRUSHED
MISCELLANEOUS BASE
COMPACTED TO 95%
RELATIVE COMPACTION
PER ASTM D1557.
TREE PROTECTION ZONE (TPZ) = CROWN DRIP LINE OR
5' OUTSIDE DRIP LINE FOR PROTECTED TREES.
MAINTAIN EXISTING
GRADE WITH THE TREE
PROTECTION FENCE
2" X 6' STEEL POSTS
OR APPROVED EQUAL.
TREE PROTECTION
FENCE: HIGH DENSITY
POLYETHYLENE
FENCING WITH 3.5" X 1.5"
OPENINGS; COLOR-
ORANGE. STEEL POSTS
INSTALLED AT 8' O.C.
5" THICK
LAYER OF MULCH.
NOTES:
1- IF EXISTING IRRIGATION IS DISRUPTED, WATER TREE BY HAND PER IRRIGATION
NOTES.
2- NO PRUNING (INCLUDING ROOT PRUNING) SHALL BE PERFORMED EXCEPT AS
DIRECTED BY APPROVED CONTRACTOR'S ARBORIST.
3- NO EQUIPMENT SHALL OPERATE INSIDE THE PROTECTIVE FENCING INCLUDING
DURING FENCE INSTALLATION AND REMOVAL.
KEEP OUT
TREE
PROTECTION
AREA
8.5" X 11" SIGN
LAMINATED
IN PLASTIC
SPACEDEVERY
50' ALONG THE
FENCE.
SECTION VIEW
FILTER FABRIC
24'
1" TO 3" COARSE
AGGREGATE
6" M
IN
A SERIES OF STEEL PLATES (3 OR
MORE) WITH RUMBLE STRIPS OR MIN 4"
COARSE AGGREGATE
LENGTH AS NEEDEDTO PREVENT TRACKING
CONSTRUCTION ENTRANCE (TC-1)
C8.1
NOT TO SCALE
CONCRETE
WASHOUT
AREA
NOTES:
1. EXCESS AND WASTE CONCRETE SHALL NOT BE WASHED INTO THE
STREET OR INTO A DRAINAGE SYSTEM.
2. FOR WASHOUT OF CONCRETE AND MORTAR PRODUCTS, A
DESIGNATED CONTAINMENT FACILITY OF SUFFICIENT CAPACITY TO
RETAIN LIQUID AND SOLID WASTE SHALL BE PROVIDED ON SITE.
3. SLURRY FROM CONCRETE AND ASPHALT SAW CUTTING SHALL BE
VACUUMED OR CONTAINED, DRIED, PICKED UP AND DISPOSED OF
PROPERLY.
4. CONCRETE ROLL OFF DUMPSTER OR CONCRETE WASHOUT AREA
SHALL BE LINED WITH A MINIMUM 10 MIL. POLYETHYLENE SHEETING.
REFER TO BMP #WM-8 FROM THE 2003 CALIFORNIA CONSTRUCTION
BMP HANDBOOK
BERMED
CONTAINMENT AREA
C8.1
NOT TO SCALE
GRAVEL BAG BARRIER (SE-6)
C8.1
NOT TO SCALE
SECTION
TYPICAL TYPICAL ELEVATION
NOT TO SCALE
GRAVEL BAGS (TYP)
GRAVEL BAGS SPACE 4'
INTERVALS
CHAIN LINK
PERIMETER
FENCE
SILT FENCE
ATTACHED TO
CHAIN LINK
FENCE BY
WIRE TIES
SILT PERIMETER FENCE (SE-1A)
C8.1
NOT TO SCALE
GRAVEL BAGS PLACE
TIGHTLY TOGETHER
ALL AROUND MATERIAL
STOCKPILED MATERIAL
STOCKPILE MANAGEMENT (WM-3)
C8.1
NOT TO SCALE
SILT FENCE (SE-1)
C8.1
NOT TO SCALE
1. STAKE DIMENSIONS ARE NOMINAL.
2. DIMENSION MAY VARY TO FIT FIELD
CONDITION.
3. STAKES SHALL BE SPACED AT 8'-0"
MAXIMUM AND SHALL BE POSITIONED
ON DOWNSTREAM SIDE OF FENCE.
4. STAKES TO OVERLAP AND FENCE
FABRIC TO FOLD AROUND EACH STAKE
ONE FULL TURN. SECURE FABRIC TO
STAKE WITH 4 STAPLES.
5. STAKES SHALL BE DRIVEN TIGHTLY
TOGETHER TO PREVENT POTENTIAL
FLOW-THROUGH OF SEDIMENT OF
JOINT. THE TOPS OF THE STAKES
SHALL BE SECURED WITH WIRE.
6. FOR END STAKE, FENCE FABRIC SHALL
BE FOLDED AROUND TWO STAKES ONE
FULL TURN AND SECURED WITH 4
STAPLES.
7. MINIMUM 4 STAPLES PER STAKE.
DIMENSIONS SHOWN ARE TYPICAL.
8. JOINING SECTIONS SHALL NOT BE
PLACED AT SUMP LOCATIONS.
LEGEND
TAMPED BACKFILL
SLOPE DIRECTION
DIRECTION OF FLOW
END STAKE DETAIL (TOP VIEW)JOINING SECTION DETAIL (TOP VIEW)
DETAIL A
PLAN SILT FENCE
SECTION A
8"
S L O
P E
6"
6"
NOTES:
STAKE B
STAKE A
FABRIC SECTION B
(SEE NOTES 6, 7, & 12)
FABRIC SECTION A
(SEE NOTES 6, 7, & 12)
FABRIC
FABRIC
(SEE NOTE 8)
2"X2" WOOD STAKE
(SEE NOTE 3)
2"X2" WOOD
STAKE (SEE
NOTES 3&5)
FABRIC, SEE
NOTE 9
SEE DETAIL A
SILT FENCE FABRIC
2"X2"
WOOD
STAKE
18" TYP.
NEW CONCRETEEXISTING CONCRETE
9" TYP.
C8.1
COATED WITH
BOND BREAKER
#4 DEFORMED TIE
BAR SPACED AT
30" MAX.
ON CENTER
DRILL 58" DIA HOLE INTO EXISTING CONCRETE. APPLY
SIMPSON SET HIGH STRENGTH EPOXY-TIE (OR
APPROVED EQUAL) ICC-ES-ESR-1772 TO BOND THE BAR
TO EXISTING CONCRETE PAVEMENT
R=1 4"
DOWELED JOINT DETAIL
C8.1
NOT TO SCALE
1' - 2 BAGS
MIN.
CONCRETE WASTE MANAGEMENT (WM-8)
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
C8.2
DETAILS
Checked
Vault File Number
Project Number
Reference North Sheet Scale
Sheet Number
Designed
Sheet Title
Supervisor
Issue Date
Drawn
Project
Description
No.
Date Issue
JCCA #: 24794-3
00000000000XXXX
DEPARTMENT OF STATE
HOSPITALS, PATTON
DEPARTMENT OF
STATE HOSPITALS
(DSH)
AS SHOWN
WEST PERIMETER
BRIDGE
DSH
07/30/2025
AC AC
F
IL
E L \2
-3
W e s t P e ri m e te r B ri d g e D
S H
-P \C
A D \2
C
.2
.d w g
D A T E /T
IM
E O c t :0
P M
JCCA
1 03-03-2025 60% DESIGN
100% SUBMITTAL
Client Agency
DEPARTMENT OF STATE HOSPITALS
385 VAN NESS AVE., SUITE 208, TORRANCE, CA 90501
P: 310.212.7644 F:310.212.5272I
2 04-23-2025 95% DESIGN
3 04-29-2025 100% DESIGN
KP KP
CONTRACTION JOINT DETAIL
C8.2
NOT TO SCALE
1/2"R 6"
#4 @12" O.C.
CONC PAVING
CONCRETE CURB WALL DETAIL
C8.2
NOT TO SCALE
BRIDGE CURB AND
PAVEMENT PER
STRUCTURALSEE CURB
DETAIL
SEE CURB
DETAIL
C8.1
C8.2
CURB CONSTRUCTION CUT SECTION
C8.2
NOT TO SCALE
8"
-1
/2
GROOVED, SAWCUT,
OR PLASTIC INSERTS
1/8" WIDE
REBAR CONTINUOUS
THROUGH JOINTS
C8.1
SLOPE
NOTES:
1. CONTRACTION JOINTS SHALL BE LOCATED AT NOT TO EXCEED 15' ON
CENTER. SEE PLANS FOR LOCATION.
2. EACH PANEL LENGTH SHALL NOT EXCEED 1.25 TIMES THE PANEL
WIDTH.
C8.2
4 CONCRETE EXPANSION JOINT
NOT TO SCALE
EXPANSION JOINT (E.J.)
EXPANSION JOINT TO BE
CONSTRUCTED TO MEET
ADA REQUIREMENTS
(MAX WIDTH 12") AND
SPACED 30' TO 50'
APART
8" PREMOLDED
EXPANSION FILLER
STRIP
/4
CONSTRUCTION DOCUMENTS V1
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/04/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject
GENERAL NOTES
100SN001
1. INTERPRETATION OF DRAWINGS & SPECIFICATIONS
A. WHERE SPECIFICATIONS HAVE BEEN PREPARED FOR THIS PROJECT, THEY ARE ARRANGED
IN SEVERAL SECTIONS, BUT SUCH SEPARATION SHALL NOT BE CONSIDERED AS THE LIMITS
OF THE WORK REQUIRED OF ANY SEPARATE TRADE. THE TERMS AND CONDITIONS OF
SUCH LIMITATIONS ARE WHOLLY BETWEEN THE CONTRACTOR AND THEIR
SUBCONTRACTORS.
B. IN GENERAL, THE WORKING DETAILS WILL INDICATE DIMENSIONS, POSITION AND KIND OF
CONSTRUCTION, AND THE SPECIFICATIONS, QUALITIES AND METHODS. ANY WORK
INDICATED ON THE WORKING DETAILS AND NOT MENTIONED IN THE SPECIFICATIONS, OR
VICE VERSA, SHALL BE FURNISHED AS THOUGH FULLY SET FORTH IN BOTH. WORK NOT
PARTICULARLY DETAILED, MARKED OR SPECIFIED, SHALL BE IDENTICAL OR SIMILAR TO LIKE
CASES OF CONSTRUCTION THAT ARE DETAILED, MARKED OR SPECIFIED. IF CONFLICTS
OCCUR ON DRAWINGS AND/OR SPECIFICATIONS, THE MOST EXPENSIVE MATERIALS OR
METHODS WILL PREVAIL.
C. SHOULD AN ERROR APPEAR IN THE WORKING DETAILS OR SPECIFICATIONS OR IN WORK
DONE BY OTHERS AFFECTING THIS WORK, THE CONTRACTOR SHALL NOTIFY THE
ENGINEER AT ONCE AND IN WRITING. IF THE CONTRACTOR PROCEEDS WITH THE WORK SO
AFFECTED WITHOUT HAVING GIVEN SUCH WRITTEN NOTICE AND WITHOUT RECEIVING THE
NECESSARY APPROVAL, DECISION OR INSTRUCTIONS IN WRITING FROM THE OWNER, THEN
THE CONTRACTOR SHALL HAVE NO VALID CLAIM AGAINST THE OWNER, FOR THE COST OF
SO PROCEEDING AND SHALL MAKE GOOD ANY RESULTING DAMAGE OR DEFECT. NO
VERBAL APPROVAL, DECISION, OR INSTRUCTION SHALL BE VALID OR BE THE BASIS FOR
ANY CLAIM AGAINST THE OWNER, ITS OFFICERS, EMPLOYEES OR AGENTS. THE
FOREGOING INCLUDES TYPICAL ERRORS IN THE SPECIFICATIONS OR NOTATIONAL ERRORS
IN THE WORKING DETAILS WHERE THE INTERPRETATION IS DOUBTFUL OR WHERE THE
ERROR IS SUFFICIENTLY APPARENT AS TO PLACE A REASONABLY PRUDENT CONTRACTOR
ON NOTICE THAT, SHOULD THE CONTRACTOR ELECT TO PROCEED, THEY ARE DOING SO AT
THEIR OWN RISK.
2. CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
3. SHOP DRAWING NOTE:
A. WHEN NOT ADDRESSED BY DIVISION 1 OF THE SPECIFICATIONS, SUBMITTALS SHALL BE
ELECTRONIC PDF FORMAT.
B. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE
TO THE STRUCTURAL ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN
CONCEPT BY INDICATING WHICH MATERIAL THE CONTRACTOR INTENDS TO FURNISH AND
INSTALL, AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS THE
CONTRACTOR INTENDS TO USE ON A STAND ALONE SET OF DOCUMENTS. DUPLICATION OF
DESIGN DOCUMENTS FOR THE PURPOSE OF SHOP DRAWINGS IS NOT ACCEPTABLE.
C. PRIOR TO FABRICATION, SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW BY THE
STRUCTURAL ENGINEER. SHOP DRAWING SUBMITTALS SHALL INCLUDE, BUT ARE NOT
NECESSARILY LIMITED TO, STRUCTURAL STEEL, REINFORCING STEEL, & GLUE-LAMINATED
BEAMS.
D. PRIOR TO SUBMISSION THE CONTRACTOR SHALL REVIEW ALL SUBMITTALS FOR
CONFORMANCE WITH THE CONTRACT DOCUMENTS AND SHALL STAMP SUBMITTALS AS
BEING "REVIEWED FOR CONFORMANCE".
E. SHOP DRAWING SUBMITTALS PROCESSED BY THE STRUCTURAL ENGINEER ARE NOT
CHANGE ORDERS.
F. ANY DETAIL ON THE SHOP DRAWINGS THAT DEVIATES FROM THE CONTRACT DOCUMENTS
SHALL CLEARLY BE MARKED WITH THE NOTE "THIS IS A CHANGE".
G. SHOP DRAWINGS OR CALCULATIONS SUBMITTED FOR REVIEW THAT REQUIRE
RESUBMITTAL FOR RE-REVIEW SHALL BE BILLED HOURLY FOR SUCH TIME TO THE GENERAL
CONTRACTOR. RE-REVIEW WILL NOT PROCEED WITHOUT WRITTEN APPROVAL FROM THE
GENERAL CONTRACTOR FOR ADDITIONAL ENGINEERING REVIEW SERVICES.
4. SAFETY NOTE:
A. IT IS THE CONTRACTORS RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS, AS
THEY APPLY TO THIS PROJECT, OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE
STATE OF CALIFORNIA LATEST EDITION, AND ALL OSHA REQUIREMENTS.
B. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION
OF ALL FORMS AND SHORING REQUIRED. SHORING INDICATIONS (LOCATION, DIRECTION,
DURATION, ETC.) ARE ONLY SHOWN ON THE STRUCTURAL DWGS WHEN REQUIRED TO
IMPLEMENT THE DESIGN INTENT OF THE FINAL WORK PRODUCT. DETERMINATION
WHETHER SHORING IS REQUIRED FOR TEMPORARY OR INTERMEDIATE CONDITIONS
DURING CONSTRUCTION IS WHOLLY THE RESPONSIBILITY OF THE CONTRACTOR.
C. THE OWNER AND THE STRUCTURAL ENGINEER DO NOT ACCEPT ANY RESPONSIBILITY FOR
THE CONTRACTOR'S FAILURE TO COMPLY WITH THESE REQUIREMENTS.
5. THE CONTRACTOR SHALL NOTIFY ENGINEER WHERE A CONFLICT OR DISCREPANCY OCCURS
BETWEEN THE STRUCTURAL DRAWINGS AND ANY OTHER PORTION OF THE CONTRACT
DOCUMENTS OR EXISTING FIELD CONDITIONS. SUCH NOTIFICATION SHALL BE GIVEN IN DUE
TIME SO AS NOT TO AFFECT THE CONSTRUCTION SCHEDULE. IN CASE OF A CONFLICT
BETWEEN STRUCTURAL DRAWINGS AND SPECIFICATIONS THE MORE RESTRICTIVE CONDITION
SHALL TAKE PRECEDENCE UNLESS WRITTEN APPROVAL HAS BEEN GIVEN FOR THE LEAST
RESTRICTIVE. CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH ENGINEER PRIOR TO
COMMENCING ANY WORK.
6. CONTRACTOR SHALL PROVIDE AN ALLOWANCE EQUAL TO 2% OF THE BID FOR STRUCTURAL
STEEL, MISC. IRON AND REINFORCING STEEL TO BE USED AT THE DISCRETION OF THE
STRUCTURAL ENGINEER. UNUSED AMOUNT TO REVERT TO THE OWNER UPON COMPLETION
OF THE JOB.
7. ANY SUBSTITUTIONS FOR STRUCTURAL MEMBERS, HARDWARE OR DETAILS SHALL BE
REVIEWED BY THE ENGINEER. SUCH REVIEW WILL BE BILLED ON A TIME AND MATERIALS BASIS
TO THE GENERAL CONTRACTOR WITH NO GUARANTEE THAT THE SUBSTITUTION WILL BE
ALLOWED.
8. DO NOT SCALE DRAWINGS. CONTACT THE ENGINEER FOR ANY DIMENSIONS NOT SHOWN.
9. THESE DRAWINGS ARE NOT COMPLETE UNTIL REVIEWED AND ACCEPTED BY LOCAL BUILDING
OFFICIALS AND THE OWNER AND SIGNED BY THE STRUCTURAL ENGINEER.
2x12 2x121x8
FTG
WIDTH
PLAN
FOUNDATIONS
200SN001
1. THE BASIS OF DESIGN AND ALLOWABLE CAPACITIES OF THE FOUNDATION SYSTEM HAVE BEEN
PROPORTIONED IN ACCORDANCE WITH THE PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
FROM SECTION 1806 OF THE CBC.
2. FOUNDATIONS SHALL BEAR ON COMPACTED FILL MATERIAL 12 INCHES IN DEPTH MAXIMUM
WITH IN-PLACE DRY DENSITY NOT LESS THAN 90-PERCENT OF THE MAXIMUM DRY DENSITY AT
OPTIMUM MOISTURE AS PRESCRIBED BY CBC SECTION 1804.6.
3. ALL FILLING, BACKFILLING AND COMPACTION SHALL BE DONE UNDER THE OBSERVATION OF A
REPRESENTATIVE OF THE GEOTECHNICAL ENGINEER AND MUST BE COMPACTED TO THE
MINIMUM DENSITY SPECIFIED IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM
D1557 AS PRESCRIBED BY CBC SECTION 1804.6
4. BOTTOMS OF ALL FOUNDATIONS SHALL BE LEVEL. CHANGES IN BOTTOM OF FOUNDATION
ELEVATION SHALL BE MADE ACCORDING TO STEPPED FOOTING DETAIL ON THE TYPICAL
DETAIL SHEET.
5. FOUNDATION CONCRETE MAY BE PLACED DIRECTLY INTO NEAT
EXCAVATIONS PROVIDED THE EXCAVATIONS ARE STABLE
(AS DETERMINED BY A REPRESENTATIVE OF THE GEOTECHNICAL
ENGINEER). OTHERWISE, FOUNDATIONS SHALL BE FULLY
FORMED. USE MINIMUM PLANKING SHOWN TO PROTECT
AGAINST SLOUGHING, AS REQUIRED. PLANKING DOES
NOT REPLACE FORMWORK REQUIRED TO STABILIZE EXCAVATION.
6. THE SURFACE OF ALL HORIZONTAL CONSTRUCTION JOINTS SHALL BE CLEANED & ROUGHENED
BY EXPOSING CLEAN AGGREGATE SOLIDLY EMBEDDED IN MORTAR MATRIX.
7. NOTIFY THE STRUCTURAL ENGINEER 48 HOURS BEFORE CASTING FOUNDATIONS.
8. A REPRESENTATIVE OF THE GEOTECHNICAL ENGINEER SHALL ADVISE THE BUILDING OFFICIAL
IN WRITING THAT:
A. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED.
B. THE FOUNDATION EXCAVATION DEPTH AND MATERIAL ARE ADEQUATE TO ACHIEVE DESIGN
BEARING CAPACITY.
(A) -
AB -
ABV -
ADDL -
AHU -
ALT -
APPROX -
ARCH -
(B) -
BLDG -
BLKG -
BLW -
BM -
B.O. -
BOF -
BOTT -
BRCG -
BRG -
BTWN -
BYND -
CC -
CG -
CJ -
CJP -
CL -
CLG -
CLR -
CMU -
COL -
CONC -
CONN -
CONT -
CONTR -
COORD -
CSK -
DBL -
DF -
DIAG -
DL -
DWG -
(E) -
EA -
EF -
EFF -
EJ -
ELEC -
ELEV -
EN -
EOS -
EQ -
ES -
EW -
EXT -
FB -
FC -
FDN -
FF -
FRMG -
FRT -
FS -
FTG -
GA -
GALV -
GLB -
GR -
GYP -
HD -
HDR -
HGR -
HK -
HORIZ -
HSB -
HSS -
HT -
INT -
OCCURS ABOVE
ANCHOR BOLT
ABOVE
ADDITIONAL
AIR HANDLING UNIT
ALTERNATE
APPROXIMATE
ARCHITECTURAL
OCCURS BELOW
BUILDING
BLOCKING
BELOW
BEAM
BOTTOM OF
BOTTOM OF FOOTING
BOTTOM
BRACING
BEARING
BETWEEN
BEYOND
CENTER TO CENTER
CENTER OF GRAVITY
CONSTRUCTION JOINT
COMPLETE JOINT PENETRATION
CENTERLINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECTION
CONTINUOUS
CONTRACTOR
COORDINATE
COUNTERSINK
DOUBLE
DOUGLAS FIR
DIAGONAL
DEAD LOAD
DRAWING
EXISTING
EACH
EACH FACE OR EDGE FASTENER
EFFECTIVE
EXPANSION JOINT
ELECTRICAL
ELEVATION
EDGE NAILING
EDGE OF SLAB
EQUAL
EACH SIDE
EACH WAY
EXTERIOR
FACE OF BLOCK/BRICK OR FLAT BAR
FACE OF CONCRETE
FOUNDATION
FINISH FLOOR
FRAMING
FIRE RETARDANT TREATED
FACE OF STUD OR FAR SIDE
FOOTING
GAUGE OR GAGE
GALVANIZED
GLUED LAMINATED BEAM
GRADE
GYPSUM
HOLDOWN
HEADER
HANGER
HOOK
HORIZONTAL
HIGH STRENGTH BOLT
HOLLOW STRUCTURAL SECTION
HEIGHT
INTERIOR
JH -
LL -
LLH -
LLV -
LONGIT -
LS -
LW -
LWC -
MECH -
MFR -
MI -
MTL -
(N) -
NIC -
NS -
NTS -
NW -
NWC -
o/ -
OD -
OH -
OPNG -
OSB -
PAF -
PC -
PERP -
PJ -
PJP -
PL -
PT -
PW -
REINF -
REQD -
RWD -
SC -
SCH -
SEOR -
SHTG -
SIM -
SJ -
SMS -
SOG -
SP -
SPCG -
SQ -
SS -
STD -
STFNR -
STGRD -
STL -
STRUCT -
SW -
T&B - T&G -
THRD -
TN -
T.O. -
TOC -
TOF -
TOS -
TOW -
TRANS -
TYP -
UNO -
VERT -
VIF -
WF -
WHS -
WP -
WS -
WWF -
XS -
XXS -
Ø -
JOIST HANGER
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
LAG SCREW
LIGHTWEIGHT
LIGHTWEIGHT CONCRETE
MECHANICAL
MANUFACTURER
MALLEABLE IRON
MARK
METAL
NEW
NOT IN CONTRACT
NEAR SIDE
NOT TO SCALE
NORMAL WEIGHT
NORMAL WEIGHT CONCRETE
OVER
OUTSIDE DIAMETER
OPPOSITE HAND
OPENING
ORIENTED STRAND BOARD
POWER ACTUATED FASTENER
PIECE
PERPENDICULAR
PANEL JOINT
PARTIAL JOINT PENETRATION
PLATE
PRESSURE TREATED OR POST-TENSIONED
PUDDLE WELD
REINFORCING OR REINFORCEMENT
REQUIRED
REDWOOD
SLIP CRITICAL
SCHEDULE
STRUCTURAL ENGINEER OF RECORD
SHEATHING
SIMILAR
SLAB CONTROL JOINT
SHEET METAL SCREW
SLAB-ON-GRADE
STRUCTURAL PANEL
SPACING
SQUARE
STAINLESS STEEL
STANDARD
STIFFENER
STAGGERED
STEEL
STRUCTURAL
SHEAR WALL
TOP & BOTTOM
TONGUE & GROOVE
THREADED
TOE NAIL
TOP OF
TOP OF CONCRETE (SLAB UNO)
TOP OF FOOTING OR TOP OF FRAMING
TOP OF STEEL
TOP OF WALL
TRANSVERSE
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
VERIFY IN FIELD
WIDE FLANGE
WELDED HEADED STUD
WORK POINT
WOOD SCREW
WELDED WIRE FABRIC
EXTRA STRONG
DOUBLE EXTRA STRONG
ROUND OR DIAMETER
ABBREVIATIONS
100SN003
CONCRETE
300SN001
1. CONCRETE SHALL ATTAIN 28 DAY COMPRESSIVE STRENGTH AS REQUIRED IN NOTE #22.
SLUMP SHALL BE 4 INCHES ± 1 INCH WITHOUT ADMIXTURES UNLESS NOTED OTHERWISE IN THE
SPECIFICATIONS.
2. CONCRETE MIX DESIGNS SHALL BE PREPARED ACCORDING TO ACI 318 CHAPTER 26.4 AND
ACI 301 SECTION 4, REVIEWED BY OWNER'S TESTING LABORATORY AND SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW.
3. CEMENTITIOUS MATERIALS:
CEMENT SHALL CONFORM TO ASTM C-150 TYPE II OR V.
FLY ASH SHALL CONFORM TO ASTM C-618. MAX. QUANTITY OF FLY ASH BY MASS SHALL BE 25%
UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS.
SLAG SHALL CONFORM TO ASTM C989. MAX. QUANTITY OF SLAG BY MASS SHALL BE 25%
UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS.
TERNARY SYSTEMS ARE PROHIBITED.
4. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33 FOR NORMAL WEIGHT CONCRETE
AND ASTM C-330 FOR LIGHTWEIGHT CONCRETE.
5. NON-SHRINK GROUT OR DRYPACK SHALL CONSIST OF A PREMIXED NONMETALLIC FORMULA.
6. REINFORCING STEEL SHALL CONFORM TO ASTM A-615 GRADE 60 UNO. REINFORCING STEEL
TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .