Well_15_Roof_Rebuild_Drawings.pdf
PDF 3 MB Posted
- Attached to
- Well #15 Roof Rebuild
- Solicitation number
- 2022-IFB-084
- Issued by
- Cook County, Illinois
About this file
The provided document is a comprehensive set of architectural and structural drawings for the Schaumburg Well #15 Roof Replacement project, prepared by 845 Design Group for the Village of Schaumburg, Illinois. The project involves a complete roof replacement for the well facility located at 325 Wise Road, Schaumburg, IL 60193. The drawings, dated March 26, 2021, include detailed plans for demolition, new construction, structural framing, elevations, sections, and specific architectural details. The scope includes removing the existing mansard roof, associated supporting components, and soffits, and installing a new roof system with metal panels, custom roof scuttle, and related architectural elements.
The technical drawings specify the use of 2-1/2" thick insulated metal panels in dark bronze to match the existing well building, with a 4" fluted face. The project will involve protecting and potentially relocating existing mechanical equipment, electrical components, and building systems. The design adheres to multiple building codes, including the 2012 International Building Code, 2018 Illinois Accessibility Code, and local Village of Schaumburg regulations. The structural engineering is conducted by McCluskey Engineering Corporation, and the drawings provide extensive details on demolition procedures, new construction methods, material specifications, and installation techniques to ensure a comprehensive and compliant roof replacement.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Well_#15_Roof_Rebuild.pdf | ||
| Well_15_Roof_Rebuild_Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING INDEX
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
A100 COVER SHEET
STRUCTURAL
S1.0 STRUCTURAL DRAWINGS
ARCHITECTURAL
A101 DEMOLITION PLANS, ELEVATIONS, AND SECTION
A102 PLANS, ELEVATIONS, AND SECTION
A300 WALL SECTIONS AND DETAILS
A400 ENLARGED PLAN DETAILS
PROJECT LOCATION
n
APPLICABLE CODES
2012 INTERNATIONAL BUILDING CODE *
CURRENT STATE OF ILLINOIS ENERGY CONSERVATION CODE*
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL PLUMBING CODE
VILLAGE OF SCHAUMBURG TITLE 15, CHAPTER 156 PLUMBING CODE STATE OF ILLINOIS PLUMBING CODE
2011 NATIONAL ELECTRICAL CODE
VILLAGE OF SCHAUMBURG TITLE 15, CHAPTER 152 ELECTRICAL CODE 2012 INTERNATIONAL MECHANICAL CODE
2012 INTERNATIONAL FIRE CODE
2018 ILLINOIS ACCESSIBILITY CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
PROJECT CONTACTS
SCHAUMBURG WELL #15 ROOF REPLACEMENT
325 W. WISE ROAD
SCHAUMBURG, IL 60193
ARCHITECT'S CERTIFICATION
I DO HEREBY CERTIFY THAT THESE PLANS AND SPECIFICATIONS
WERE PREPARED UNDER MY SUPERVISION AND TO THE BEST OF
MY KNOWLEDGE COMPLY WITH THE CODES AND BUILDING
ORDINANCES OF THE VILLAGE OF <VILLAGE NAME> AND
<COUNTY NAME>, ILLINOIS.
CLIENT
VILLAGE OF SCHAUMBURG
SCHAUMBURG WELL #15
325 WISE ROAD
SCHAUMBURG, IL 60193
ARCHITECT OF RECORD
845 DESIGN GROUP
106 CALENDAR CT. #131
LAGRANGE, IL 60525
STRUCTURAL ENGINEER
McCLUSKEY ENGINEERING CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335
CODE REVIEW MATRIX
SCHAUMBURG WELL #15
ROOF REPLACEMENT
325 WISE ROAD
SCHAUMBURG, IL 60193
ISSUE FOR BID AND PERMIT
03.26.2021
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
SCALE: AS NOTED
DATE: 03.26.2021
DRAWN: NB
APPROVED: JZ
PROJECT #: 20.01.04
SHEET NUMBER:
This drawing must not be scaled.
The general contractor shall verify all dimensions, datums and levels prior to commencement of work. All errors and omissions to be reported immediately to the architect.
Variations and modifications to work shown on these drawings shall not be carried out without written permission from the architect. This drawing is the exclusive property of the architects and can be reproduced only with the permission of the architects, in which case the reproduction must bear their name as architects.
2021 845 Design Group P.C.©
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
SCHAUMBURG WELL #15
325 WISE ROAD
SCHAUMBURG, IL 60193
STRUCTURAL ENGINEERS
McCLUSKEY ENGINEERING
CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335 ■ FAX: 630-717-5397
c MEC JOB #: 20131 mec
STRUCTURAL CONSULTANT
mark date description
3/26/2021 ISSUE FOR BID/PERMIT
ST
AT E OF I L L I NO I S
L I C E N S E D
S T R U C T U R A L E NG I N
E E R
License Expires: 11/30/2022
SETH
MICHAEL
081-005034
NAPERVILLE
IL
Date: 03/26/2021
S1.0
AutoCAD SHX Text
NOTE 1
AutoCAD SHX Text 2 x 12 @ 16" O.C.
AutoCAD SHX Text
TYPICAL U.N.O.
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text D1
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
(ELEV., O.H.)
AutoCAD SHX Text O.H.
AutoCAD SHX Text
(E) LINTEL
AutoCAD SHX Text
(E) LINTEL
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
NOTE 2
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
(ELEV.)
AutoCAD SHX Text 4x6 + 2x8 RIM JOIST
AutoCAD SHX Text 4x6 + 2x8 RIM JOIST
AutoCAD SHX Text 2 x 8 @ 16" O.C.
AutoCAD SHX Text
TYPICAL THIS BAY
AutoCAD SHX Text 4x6 + 2x8 RIM JOIST
AutoCAD SHX Text 4x6 + 2x8 RIM JOIST
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text D1
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text HSS5 x 3 x 5/16 W/ 2x6 NAILER W/ 1/2" LINDAPTERHOLLOW-BOLT @ 32" O.C.
AutoCAD SHX Text L8 x 4 x 1/2 W/ 5/8" KWIK HUS EZ ANCHORS @ 8" O.C. (STAGGERED)
AutoCAD SHX Text L4 x 3 x 5/16 W/ 3/4" REMOVABLE BOLTS @ 12" O.C.
AutoCAD SHX Text 2x6 GIRTS @ 16" O.C. (VERT)
AutoCAD SHX Text
GROUT EXISTING CMU SOLID FULL HEIGHT (16" WIDE MIN.)
AutoCAD SHX Text
(INTERIOR)
AutoCAD SHX Text
(EXTERIOR)
AutoCAD SHX Text
1/4" COMPRESSIBLE FILLER SEE ARCH
AutoCAD SHX Text
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text 2x ROOF JOISTS SEE PLAN
AutoCAD SHX Text SIMPSON HGA10 BTWN. EACH 2x ROOF JOIST
AutoCAD SHX Text
SIMPSON A23 (N.S. & F.S.) EACH END
AutoCAD SHX Text 2x RIM JOIST SEE PLAN
AutoCAD SHX Text
DBL LVL SEE PLAN
AutoCAD SHX Text
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text 2x ROOF JOISTS SEE PLAN
AutoCAD SHX Text 4x6 SEE PLAN
AutoCAD SHX Text 3/4" STRUCTURAL 1 SHEATHING (SANDED), EXTERIOR GRADE W/ (2) 1/2" BOLTS @ 12" O.C. ATHEADER AND (1) 12d NAIL AT PANEL EDGES AND INTERMEDIATE SUPPORTS.
AutoCAD SHX Text
REMOVABLE 3/4" LAGSCREWS @ 12" O.C.
AutoCAD SHX Text 2x RIM JOIST SEE PLAN
AutoCAD SHX Text
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text DBL 2x HEADER SEE PLAN
AutoCAD SHX Text 4x6 (LSH) SEE PLAN
AutoCAD SHX Text
CONT. 5/16"
AutoCAD SHX Text SIMPSON HGA10 BETWEEN EACH 2x ROOF JOIST
AutoCAD SHX Text 2x RIM JOIST SEE PLAN
AutoCAD SHX Text HSS5 x 3 x 516LSH
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
(DOOR OPENING SEE ARCH)
AutoCAD SHX Text
B/FRAME
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
T/EXIST. MASONRY
AutoCAD SHX Text
FIELD VERIFY
AutoCAD SHX Text
T/STEEL
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text S1.0
AutoCAD SHX Text
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text GENERAL STRUCTURAL NOTES DESIGN AND LOADING: 1. STRUCTURAL DESIGN OF THIS BUILDING IS IN ACCORDANCE WITH THE INTERNATIONAL STRUCTURAL DESIGN OF THIS BUILDING IS IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2015 EDITION AS ADOPTED AND AMENDED BY THE VILLAGE OF SCHAUMBURG, ILLINOIS. 2. SNOW LOADS: SNOW LOADS: A. GROUND SNOW LOAD - Pg = 25 PSF GROUND SNOW LOAD - Pg = 25 PSF - Pg = 25 PSF Pg = 25 PSF = 25 PSF 25 PSF B. FLAT-ROOF SNOW LOAD - Pf = 21 PSF FLAT-ROOF SNOW LOAD - Pf = 21 PSF - Pf = 21 PSF Pf = 21 PSF = 21 PSF 21 PSF C. SNOW EXPOSURE FACTOR - Ce = 1.0 SNOW EXPOSURE FACTOR - Ce = 1.0 - Ce = 1.0 Ce = 1.0 = 1.0 1.0 D. SNOW LOAD IMPORTANCE FACTOR - I = 1.0 SNOW LOAD IMPORTANCE FACTOR - I = 1.0 - I = 1.0 I = 1.0 = 1.0 1.0 E. THERMAL FACTOR(Ct) - 1.2 THERMAL FACTOR(Ct) - 1.2 - 1.2 1.2 3. WIND LOADS: WIND LOADS: A. BASIC WIND SPEED - 115 MPH BASIC WIND SPEED - 115 MPH - 115 MPH 115 MPH B. RISK CATEGORY - II RISK CATEGORY - II - II II C. WIND LOAD (CC) - 24.6 PSF (50 S.F.) (1.0W)WIND LOAD (CC) - 24.6 PSF (50 S.F.) (1.0W)- 24.6 PSF (50 S.F.) (1.0W)24.6 PSF (50 S.F.) (1.0W)
AutoCAD SHX Text MISCELLANEOUS: 1. ALL DIMENSIONS ON STRUCTURAL DRAWINGS ARE TO BE CHECKED AGAINST ALL DIMENSIONS ON STRUCTURAL DRAWINGS ARE TO BE CHECKED AGAINST ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND EXISTING CONDITIONS BY THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR. ANY DISCREPANCIES ARE TO BE REPORTED TO THE ARCHITECT IMMEDIATELY. 2. THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. AS PART OF HIS RESPONSIBILITY, THE CM/GC SHALL RETAIN THE SERVICES OF A LICENSED STRUCTURAL ENGINEER TO DESIGN AND SUPERVISE ANY SCAFFOLDING FOR WORKMEN AND ALL SHORING OF FORMS AND ELEMENTS OF CONSTRUCTION. 3. DO NOT SCALE THE DRAWINGS. DO NOT SCALE THE DRAWINGS. 4. ALL EXISTING DIMENSIONS AND CONDITIONS MUST BE FIELD VERIFIED PRIOR TO ALL EXISTING DIMENSIONS AND CONDITIONS MUST BE FIELD VERIFIED PRIOR TO FABRICATION. McCLUSKEY ENGINEERING CORPORATION SHALL NOT BE RESPONSIBLE FOR ANY EXISTING INFORMATION SUPPLIED BY THE OWNER/ARCHITECT NOR BE LIABLE FOR THOSE EXISTING CONDITIONS THAT VARY FROM THAT INFORMATION. ADDITIONALLY, DESIGN WORK RESULTING FROM THE VARIATION OF EXISTING CONDITIONS WILL BE PERFORMED AS AN ADDITIONAL SERVICE. 5. THE CM/GC SHALL PROVIDE AND COORDINATE THE TEMPORARY STABILIZATION AND THE CM/GC SHALL PROVIDE AND COORDINATE THE TEMPORARY STABILIZATION AND SUPPORT OF ALL STRUCTURAL ELEMENTS DURING THE ERECTION PROCESS (E.G. TEMPORARY GUYS, BEAMS, FALSEWORK, ETC). THESE TEMPORARY SUPPORTS SHALL BE SUFFICIENT TO SECURE ALL STRUCTURAL ELEMENTS OR ANY PORTION THEREOF AGAINST LOADS THAT ARE LIKELY TO BE ENCOUNTERED DURING ERECTION, INCLUDING THOSE DUE TO WIND AND THOSE THAT RESULT FROM ERECTION OPERATIONS. THE FINAL LATERAL STABILITY OF STRUCTURE SHALL NOT BE RELIED UPON PRIOR TO THE COMPLETE ERECTION OF ALL STRUCTURAL ELEMENTS.
AutoCAD SHX Text STRUCTURAL STEEL: 1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", AND THE AISC "CODE OF STANDARD PRACTICE", LATEST EDITIONS. 2. STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATIONS (UNLESS OTHERWISE STEEL SHALL CONFORM TO THE FOLLOWING ASTM SPECIFICATIONS (UNLESS OTHERWISE NOTED): A) ANGLES/PLATES - A-36 ANGLES/PLATES - A-36 - A-36 A-36 B) STRUCTURAL TUBING - A-500 GRADE B STRUCTURAL TUBING - A-500 GRADE B - A-500 GRADE B A-500 GRADE B C) STRUCTURAL BOLTS - A-325 TYPE N STRUCTURAL BOLTS - A-325 TYPE N - A-325 TYPE N A-325 TYPE N D) EXPANSION ANCHORS - STUD TYPE, BY HILTI, OR EQUIVALENT. EXPANSION ANCHORS - STUD TYPE, BY HILTI, OR EQUIVALENT. - STUD TYPE, BY HILTI, OR EQUIVALENT. STUD TYPE, BY HILTI, OR EQUIVALENT. E) WELDING ELECTRODES - E-70XX WELDING ELECTRODES - E-70XX - E-70XX E-70XX 3. ALL WELDING ELECTRODES SHALL BE E-70XX. ALL SHOP AND FIELD WELDING SHALL BE ALL WELDING ELECTRODES SHALL BE E-70XX. ALL SHOP AND FIELD WELDING SHALL BE MADE IN ACCORDANCE WITH A.W.S. D1.1 "CODE FOR WELDING IN BUILDING CONSTRUCTION," LATEST EDITION AND SHALL BE MADE BY QUALIFIED "CERTIFIED" WELDERS. PROVIDE MINIMUM WELD SIZE PER AISC J2.1 AND J2.2. 4. UNLESS SPECIFICALLY EXCLUDED, ALL STRUCTURAL STEEL SHALL RECEIVE ONE COAT OF UNLESS SPECIFICALLY EXCLUDED, ALL STRUCTURAL STEEL SHALL RECEIVE ONE COAT OF APPROVED SHOP PAINT, AS SPECIFIED IN THE ARCHITECTURAL SPECIFICATIONS. 5. GALVANIZE STEEL LOCATED IN EXTERIOR WALLS.GALVANIZE STEEL LOCATED IN EXTERIOR WALLS.
AutoCAD SHX Text SHORING REQUIREMENTS: 1. CONTRACTOR IS FULLY RESPONSIBLE FOR PROVIDING ALL TEMPORARY SHORING AND CONTRACTOR IS FULLY RESPONSIBLE FOR PROVIDING ALL TEMPORARY SHORING AND BRACING OF EXISTING STRUCTURAL ELEMENTS DURING CONSTRUCTION. ALL SHORING SHALL BE ADEQUATE TO SUPPORT ALL STRUCTURAL LOADINGS DURING MODIFICATION OF THE EXISTING BUILDING AND ERECTION OF THE NEW STRUCTURAL SUPPORT SYSTEM. TEMPORARY SHORING MUST REMAIN IN PLACE UNTIL ALL NEW STRUCTURAL MEMBERS SUPPORTING SHORED ELEMENTS ARE IN PLACE AND ALL NEW CONNECTIONS COMPLETED. SUBMIT DETAILS AND CALCULATIONS SIGNED AND SEALED BY A LICENSED STRUCTURAL ENGINEER IN THE PROJECT STATE FOR REVIEW. 2. SHORING AND BRACING WORK SHALL BE PERFORMED BY A SHORING CONTRACTOR WITH A SHORING AND BRACING WORK SHALL BE PERFORMED BY A SHORING CONTRACTOR WITH A MINIMUM OF FIVE YEARS EXPERIENCE IN SIMILAR TYPE OF WORK. 3. PRIOR TO START OF WORK, ESTABLISH AND DOCUMENT ELEVATIONS OF THE EXITING PRIOR TO START OF WORK, ESTABLISH AND DOCUMENT ELEVATIONS OF THE EXITING CONSTRUCTION AT INTERVALS ALONG THE WALLS TO BE REMOVED. CONTINUOUSLY MONITOR THE ELEVATION DURING DEMOLITION AND CONSTRUCTION OPERATIONS. METHOD OF SHORING SHOULD HAVE PROVISIONS FOR ADJUSTMENT TO MAINTAIN ELEVATIONS OF EXISTING CONSTRUCTION.
AutoCAD SHX Text WOOD: 1. COMPLY WITH THE FOLLOWING PUBLISHED STANDARDS, LATEST EDITIONS: COMPLY WITH THE FOLLOWING PUBLISHED STANDARDS, LATEST EDITIONS: A) LUMBER - AMERICAN SOFTWOOD LUMBER STANDARD (PS-20) LUMBER - AMERICAN SOFTWOOD LUMBER STANDARD (PS-20) - AMERICAN SOFTWOOD LUMBER STANDARD (PS-20) AMERICAN SOFTWOOD LUMBER STANDARD (PS-20) B) PLYWOOD - CONSTRUCTION AND INDUSTRIAL PLYWOOD (PS1) PLYWOOD - CONSTRUCTION AND INDUSTRIAL PLYWOOD (PS1) - CONSTRUCTION AND INDUSTRIAL PLYWOOD (PS1) CONSTRUCTION AND INDUSTRIAL PLYWOOD (PS1) C) GLUED LAMINATED BEAMS AND LAMINATED GLUED LAMINATED BEAMS AND LAMINATED VENEER LUMBER - AMERICAN INSTITUTE OF TIMBER CONSTRUCTION - AMERICAN INSTITUTE OF TIMBER CONSTRUCTION AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 2. MINIMUM LUMBER GRADES SHALL BE DOUGLAS FIR-LARCH NO. 1, WITH A MAXIMUM MINIMUM LUMBER GRADES SHALL BE DOUGLAS FIR-LARCH NO. 1, WITH A MAXIMUM MOISTURE CONTENT OF 19%, UNLESS NOTED OTHERWISE ON PLAN AND/OR DETAILS. 3. COMMON NAILS SHALL BE USED. COMMON NAILS SHALL BE USED. 4. LAG BOLTS (& SCREWS) SHALL BE PREDRILLED TO SHANK DIAMETER AND FULL DEPTH LAG BOLTS (& SCREWS) SHALL BE PREDRILLED TO SHANK DIAMETER AND FULL DEPTH AND SCREWED (NOT DRIVEN) INTO PLACE. 5. STANDARD CUT WASHERS SHALL BE PLACED UNDER HEADS AND NUTS OF ALL BOLTS STANDARD CUT WASHERS SHALL BE PLACED UNDER HEADS AND NUTS OF ALL BOLTS BEARING ON WOOD, AND UNDER HEADS OF LAG BOLTS. ONE CUT WASHER SHALL BE USED FOR BOLTS CONNECTING WOOD LEDGERS TO CONCRETE OR MASONRY WALLS. 6. PROVIDE 1" X 4" OR METAL CROSS BRIDGING NOT OVER 6 FEET ON CENTER FOR ALL PROVIDE 1" X 4" OR METAL CROSS BRIDGING NOT OVER 6 FEET ON CENTER FOR ALL WOOD JOISTS. PROVIDE SOLID BLOCKING OF THE SAME DIMENSIONS AS THE JOISTS BETWEEN JOISTS AT SUPPORTS. 7. PROVIDE SOLID FULL DEPTH 2x BLOCKING AT 8 FEET MAX O.C. AT 2x ROOF FRAMING. PROVIDE SOLID FULL DEPTH 2x BLOCKING AT 8 FEET MAX O.C. AT 2x ROOF FRAMING. 8. ROOF SHEATHING SHALL BE 19/32” APA RATED SHEATHING, EXPOSURE 1, 40/20. LAY ROOF SHEATHING SHALL BE 19/32” APA RATED SHEATHING, EXPOSURE 1, 40/20. LAY APA RATED SHEATHING, EXPOSURE 1, 40/20. LAY UP WITH MINIMUM 1/8” CLEAR BETWEEN PANELS TO ALLOW FOR EXPANSION. ROOF CLEAR BETWEEN PANELS TO ALLOW FOR EXPANSION. ROOF SHEATHING SHALL BE FASTENED TO SUPPORTING MEMBERS W/10d NAILS @ 6” O.C. AT O.C. AT PANEL EDGES, AND 12” O.C. AT INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. O.C. AT INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. 9. MINIMUM NAILED CONNECTIONS FOR WOOD FRAMING MEMBERS SHALL BE IN ACCORDANCE MINIMUM NAILED CONNECTIONS FOR WOOD FRAMING MEMBERS SHALL BE IN ACCORDANCE WITH THE FASTENING SCHEDULE GIVEN IN TABLE 2304.9.1 OF THE INTERNATIONAL BUILDING CODE, LATEST EDITION IF NO OTHER CRITERIA IS GIVEN. 10. ALL JOIST HANGERS AND FRAMING CONNECTORS SHOWN ARE TO BE MANUFACTURED BY ALL JOIST HANGERS AND FRAMING CONNECTORS SHOWN ARE TO BE MANUFACTURED BY SIMPSON STRONG TIE. ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY ENGINEER OR ARCHITECT OF RECORD. 11. LAMINATED VENEER LUMBER SHALL BE MICRO-LAM, AS MANUFACTURED BY TRUS JOIST OR LAMINATED VENEER LUMBER SHALL BE MICRO-LAM, AS MANUFACTURED BY TRUS JOIST OR EQUIVALENT AND SHALL THE FOLLOWING MINIMUM PROPERTIES: A) MODULUS OF ELASTICITY - E = 2000 KSI MODULUS OF ELASTICITY - E = 2000 KSI - E = 2000 KSI E = 2000 KSI B) FLEXURAL STRESS - Fb = 2600 PSI FLEXURAL STRESS - Fb = 2600 PSI - Fb = 2600 PSI Fb = 2600 PSI C) HORIZONTAL SHEAR PERP. TO GRAIN - Fv = 285 PSIHORIZONTAL SHEAR PERP. TO GRAIN - Fv = 285 PSI- Fv = 285 PSIFv = 285 PSI
AutoCAD SHX Text EXISTING CONSTRUCTION: 1. VERIFY ALL EXISTING DIMENSIONS AND STRUCTURAL FRAMING AS SHOWN ON THESE VERIFY ALL EXISTING DIMENSIONS AND STRUCTURAL FRAMING AS SHOWN ON THESE STRUCTURAL DRAWINGS PRIOR TO STARTING ON ANY WORK. RECORD AND NOTIFY THE ARCHITECT OF ALL INCONSISTENCIES IN WRITING. 2. ALL SLABS, DECKS AND BEAMS IN THE AREA OF NEW OPENINGS ARE TO BE SHORED ALL SLABS, DECKS AND BEAMS IN THE AREA OF NEW OPENINGS ARE TO BE SHORED PRIOR TO START OF WORK. 3. ALL OPENINGS SHALL BE SAW CUT OR CORED, SIMPLE HAMMERING WITHOUT SAW CUTS ALL OPENINGS SHALL BE SAW CUT OR CORED, SIMPLE HAMMERING WITHOUT SAW CUTS OR CORES IS NOT ALLOWED. 4. DO NOT CUT, CORE OR HAMMER THROUGH OR INTO ANY EXISTING FRAMING UNLESS DO NOT CUT, CORE OR HAMMER THROUGH OR INTO ANY EXISTING FRAMING UNLESS SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS OR NOTED IN WRITING FROM THE STRUCTURAL ENGINEER. 5. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL OPENING LOCATIONS. SEE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR ALL OPENING LOCATIONS. CONTRACTOR SHALL ASSUME THAT A NEW OPENING IS REQUIRED FOR ALL MECHANICAL RISERS SHOWN. AT LOCATIONS OF MECHANICAL PENETRATIONS FOR WHICH NEW FRAMING IS NOT SHOWN ON THE STRUCTURAL DRAWINGS, THE PENETRATION SHALL BE LOCATED BETWEEN EXISTING BEAMS WITHOUT DAMAGE TO THEM AS PER NOTE 4. SHOULD ANY PENETRATION REQUIRE AN OPENING LARGER THAN THE SPACE AVAILABLE BETWEEN EXISTING STRUCTURAL MEMBERS AND NEW FRAMING IS NOT EXPLICITLY SHOWN ON THE STRUCTURAL DRAWINGS, THE CONTRACTOR SHALL CONTACT THE ARCHITECT PRIOR TO PROCEEDING WITH WORK. 6. NO HORIZONTAL PENETRATIONS OF JOISTS SHALL BE PERMITTED UNLESS EXPLICITLY NO HORIZONTAL PENETRATIONS OF JOISTS SHALL BE PERMITTED UNLESS EXPLICITLY SHOWN ON THE STRUCTURAL DRAWINGS.
AutoCAD SHX Text HSS5 x 3 W/ " PLATE EA. 38" PLATE EA. END
AutoCAD SHX Text 2x6 GIRTS W/ SIMPSON A23 AT EACH END (T&B)
AutoCAD SHX Text L8x4 - SEE DET. 4
AutoCAD SHX Text HSS5 x 3 (LSH) W/ 38" PLATE EA. END
AutoCAD SHX Text
EXIST MASONRY TO REMAIN
AutoCAD SHX Text
(3) 10d NAILS @ 12" O.C.
AutoCAD SHX Text DBL. 2x12
AutoCAD SHX Text
(2) SDS SCREWS @ 16" O.C.
AutoCAD SHX Text
DBL. 11 " LVL 14" LVL
AutoCAD SHX Text
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text DOUBLE 2 x 8 WOOD PLATES CONT. (LOWER PLATE PRESSURE TREATED) W/ 5/8" HILTI KWIKBOLT 3 (3 1/2" EMBED) @ 32" O.C., MIN.
AutoCAD SHX Text
EXISTING MASONRY FIELD VERIFY
AutoCAD SHX Text 2x RIM BOARD
AutoCAD SHX Text 2x ROOF JOISTS SEE PLAN
AutoCAD SHX Text
ROOF SHEATHING SEE PLAN
AutoCAD SHX Text DOUBLE 2 x 8 WOOD PLATES CONT. (LOWER PLATE PRESSURE TREATED) W/ 5/8" HILTI KWIKBOLT 3 (3 1/2" EMBED) @ 32" O.C., MIN.
AutoCAD SHX Text
EXISTING MASONRY FIELD VERIFY
AutoCAD SHX Text DOUBLE 2x JOIST
AutoCAD SHX Text 2x ROOF JOISTS SEE PLAN
AutoCAD SHX Text
2X BLOCKING SEE GENERAL NOTES
AutoCAD SHX Text
ROOF SHEATHING SEE PLAN
AutoCAD SHX Text
GROUT EXISTING TOP COURSE SOLID
AutoCAD SHX Text
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text CONT. 3/8" x 7" W/ W/ 3/4" THRU-BOLTS @ 12"O.C. DAMAGE THREADS TO PREVENT LOOSENING
AutoCAD SHX Text
REMOVABLE 3/4" LAG SCREW @ 12" O.C.
AutoCAD SHX Text CONT. 3/8" x 7" W/ W/ 3/4" THRU-BOLTS @ 12"O.C. DAMAGE THREADS TO PREVENT LOOSENING
AutoCAD SHX Text 3/4" STRUCTURAL 1 SHEATHING (SANDED), EXTERIOR GRADE W/ (2) 12d NAILS @ 6" O.C. AT DBL LVL AND (1) 12d NAIL AT PANEL EDGES AND INTERMEDIATE SUPPORTS.
AutoCAD SHX Text 4x6 (LSH) SEE PLAN
AutoCAD SHX Text HSS5x3
AutoCAD SHX Text
GROUT EXISTING TOP COURSE SOLID
AutoCAD SHX Text 4x4 CONT.
AutoCAD SHX Text 2x4 STUDS @ 16" O.C.
AutoCAD SHX Text
REMOVABLE 3/4" LAGSCREWS @ 12" O.C.
AutoCAD SHX Text 2x BLOCKING SEE GENERAL NOTES
AutoCAD SHX Text 12d @ 6" O.C.
AutoCAD SHX Text 4x4 CONT.
AutoCAD SHX Text 2x4 STUDS @ 16" O.C.
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH
AutoCAD SHX Text SIMPSON HGA10 BETWEEN EACH 2x ROOF JOIST
AutoCAD SHX Text 2x BLOCKING SEE GENERAL NOTES
AutoCAD SHX Text
B/JOIST
AutoCAD SHX Text
SEE ARCH.
AutoCAD SHX Text NOTES: 1. PROVIDE DOUBLE 2 x 12 HEADER W/ SIMPSON HUS212-2TF EACH END. SEE DETAIL 6/S1.0 PROVIDE DOUBLE 2 x 12 HEADER W/ SIMPSON HUS212-2TF EACH END. SEE DETAIL 6/S1.0 FOR FASTENER PATTERN. 2. PROVIDE DOUBLE 1.75" X 11.25" LVL BEAM. SEE DETAIL 6/S1.0 FOR FASTENER PATTERN PROVIDE DOUBLE 1.75" X 11.25" LVL BEAM. SEE DETAIL 6/S1.0 FOR FASTENER PATTERN 3. CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL ROOF PENETRATIONS, MECHANICAL CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL ROOF PENETRATIONS, MECHANICAL EQUIPMENT, ETC. WITH ARCHITECTURAL AND MECHANICAL DRAWINGS. 4. VERIFY ALL ROOF OPENING SIZES & LOCATIONS WITH THE ARCHITECTURAL AND MECHANICAL VERIFY ALL ROOF OPENING SIZES & LOCATIONS WITH THE ARCHITECTURAL AND MECHANICAL DRAWINGS. 5. D1 - INDICATES 19/32" STRUCTURAL 1 ROOF SHEATHING. SEE GENERAL STRUCTURAL NOTES D1 - INDICATES 19/32" STRUCTURAL 1 ROOF SHEATHING. SEE GENERAL STRUCTURAL NOTES FOR ADD'L INFORMATION. 6. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN, ROOF SLOPES, ETC.SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN, ROOF SLOPES, ETC.
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
ROOF FRAMING PLAN
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
HIGH ROOF FRAMING PLAN
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text NOTES: 1. D1 - INDICATES 19/32" STRUCTURAL 1 ROOF SHEATHING. SEE GENERAL STRUCTURAL NOTES D1 - INDICATES 19/32" STRUCTURAL 1 ROOF SHEATHING. SEE GENERAL STRUCTURAL NOTES FOR ADD'L INFORMATION. 2. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN, ROOF SLOPES, ETC. SEE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN, ROOF SLOPES, ETC. 3. SEE ARCHITECTURAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.SEE ARCHITECTURAL DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION.
boxx Line
DEMOLITION PLANS,
ELEVATIONS, AND SECTIONS
A101
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
SCALE: AS NOTED
DATE: 03.26.2021
DRAWN: NB
APPROVED: JZ
PROJECT #: 20.01.04
SHEET NUMBER:
This drawing must not be scaled.
The general contractor shall verify all dimensions, datums and levels prior to commencement of work. All errors and omissions to be reported immediately to the architect.
Variations and modifications to work shown on these drawings shall not be carried out without written permission from the architect. This drawing is the exclusive property of the architects and can be reproduced only with the permission of the architects, in which case the reproduction must bear their name as architects.
2021 845 Design Group P.C.©
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
SCHAUMBURG WELL #15
ROOF REPLACEMENT
325 WISE ROAD
SCHAUMBURG, IL 60193
# date description
3/26/2021 ISSUE FOR BID/PERMIT
STRUCTURAL ENGINEERS
McCLUSKEY ENGINEERING
CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335 ■ FAX: 630-717-5397
c MEC JOB #:
mec
STRUCTURAL CONSULTANT
ISSUE FOR BID AND PERMIT
SCALE: 1/4" = 1'-0"
DEMO PLAN
n
SCALE: 1/4" = 1'-0"
DEMO ROOF PLAN
SCALE: 1/4" = 1'-0"
DEMO SECTION AT ROOF HATCH/WALL OPENING
SCALE: 1/4" = 1'-0"
DEMO ELEVATION
SCALE: 1/4" = 1'-0"
DEMO SECTION AT TYPICAL WALL FRAMING
DEMO SYMBOL LEGEND
GENERAL DEMO NOTES
DEMOLITION TYPE NOTES
1. DEMOLISH AND DISPOSE OF MATERIALS IN ACCORDANCE WITH AUTHORITY
HAVING JURISDICTION
2. SALVAGE, STORE AND PROTECT ANY ITEMS PLANNED FOR REINSTALLATION.
OWNER SHALL MAINTAIN RIGHT TO SALVAGE ANY ITEMS REMOVED.
3. G.C. TO USE SKILLED LABOR TRAINED IN THE NECESSARY TRADES FOR
DEMOLITION AND ITEM REMOVAL
4. G.C. TO MONITOR WORK AND INFORM OWNER OR ARCHITECT OF ANY
UNFORESEEN CONDITIONS.
5. G.C. TO VERIFY EXISTING LOCATIONS OF ALL UTILITY AND UTLITY LINES. SHUT
OFF, CAP AND PROTECT EXISTING UTILITIES INCLUDING PLUMBING, MECHANICAL,
ELECTRICAL AND FIRE PROTECTION AS REQUIRED IN ACCORDANCE WITH
AUTHORITIES HAVING JURISDICTION. LABEL AND INDICATE ANY SHUT OFF POINTS
AS REQ'D.
6. COMPLETELY REMOVE ITEMS CALLED FOR DEMOLITION. SURFACES TO BE
CLEANED AND PREPARED FOR NEW WORK
7. JOB SITE TO REMAIN CLEAN AND CLOSED OFF AS REQ'D WITH MINIMAL VISUAL
DISRUPTION TO THE ADJACENT PROPERTIES.
8. G.C. TO BE RESPONSIBLE FOR ALL DEMOLITION WORK DONE IN COMPLIANCE
WITH THE SCOPE OF WORK.
9. G.C. TO BE RESPONSIBLE FOR ALL TEMPORARY SHORING, BRACING, NEEDLING
OR WEATHER PROOFING AS REQ'D. AREAS WITHIN SCOPE TO REMAIN
STRUCTURALLY SOUND AND CLOSED OFF FROM ELEMENTS. COORDINATE PLAN
WITH OWNER AND ARCHITECT AS NEEDED.
10. AUTHORITY HAVING JURISDITION SHALL APPROVE PROTECTION PLAN PRIOR TO
IMPLIMENTATION.
REMOVE ALL EXISTING MANSARD ROOF INCLUDING ALL MATERIALS,
SHINGLES, AND ASSOCIATED SUPPORTING/STRUCTURAL
COMPONENTS AND SOFFITS ALL SIDES TYP.
PLAN NOTE DESIGNATION
SECTION TAG
REMOVE UPPER PORTION OF WOOD PANEL OPENING INCLUDING
TOP HEADER, BOX COLUMN AND 3" THICK PANELS
LOWER PORTION OF WOOD PANEL OPENING TO BE REMOVED. PREP
ADJACENT BLOCK OPENINGS FOR NEW WORK.
EXISTING DOOR TO REMAIN. PROTECT DURING CONSTRUCTION.
CUT BACK AND REMOVE ALL EXISTING JOIST AS REQ'D
- SEE STRUCTURAL DRAWINGS FOR NEW WORK
REMOVE EXIST. GUTTER & DOWN SPOUTS
EXISTING BRICK TO REMAIN. CLEAN BRICK WHERE MANSARD
CONSTRUCTION IS REMOVED PREP FOR NEW WORK. V.I.F.
EXISTING BRICK & BLOCK WALL TO REMAIN9
EXISTING SLAB & FOUNDATION TO REMAIN
EXISTING LIGHT TO REMAIN11
EXISTING EXHAUST FAN (2 TOTAL) TO BE DISCONNECT, SALVAGED &
REINSTALLED WITH NEW CURB IN NEW ROOF. (V.I.F.) DISCONNECT &
CAP AS NEEDED FOR FUTURE RECONNECTION. BACKDRAFT
DAMPER HARDWIRED W/ CONDUIT TO EXISTING ELEC.
REMOVE EXISTING SCUTTLE LID CONSTRUCTION
EXISTING PUMP CONC. PLATIFORM & EQUIPMENT TO REMAIN.
PROTECT ALL INTERIOR EQUIPMENT PRIOR TO DEMO.
EXIST. GAS VENT PIPE TO REMAIN. EXTEND AS NEEDED PER
AUTHORITY HAIING JURISDICTION ABOVE NEW ROOF HEIGHT. (V.I.F.)
PROVIDE NEW CURB/BOOT & FLASHING TO NEW ROOF.
REMOVE EXISTING ROOFING MEMBRANE, INSULATION, DECKING
AND MATERIALS DOWN TO STRUCTURAL COMPONENTS (TYP.)
VERIFY EXISTING CONDITIONS. REMOVE JOISTS AND PREP SILL FOR
NEW WORK - SEE STRUCTURAL
EXISTING UNDERSIDE CEILING COMPONENTS: LIGHTING, FIRE
ALARM, MECHANICAL, CONDUIT, ETC TO BE SALVAGED AND
REINSTALLED IN PLACE. G.C. TO COORDINATE SALVAGE AS REQ'D
SEE SHEET A102 FOR REFERENCE
EXISTING MASONRY TO REMAIN - G.C. TO COORDINATE EXTENT OF
MASONRY WORK REQ'D WITH NEW WORK
AutoCAD SHX Text
B/ EXIST. SOFFIT
AutoCAD SHX Text
EL: +8'-4" (VIF)
AutoCAD SHX Text
AutoCAD SHX Text A101
AutoCAD SHX Text
AutoCAD SHX Text A101
AutoCAD SHX Text
B/ EXIST. SOFFIT
AutoCAD SHX Text
EL: +8'-4" (VIF)
AutoCAD SHX Text
T/ EXIST. CMU
AutoCAD SHX Text
EL: +12'-0" (VIF)
AutoCAD SHX Text
B/ EXIST. SOFFIT
AutoCAD SHX Text
EL: +8'-4" (VIF)
AutoCAD SHX Text
T/ EXIST. CMU
AutoCAD SHX Text
EL: +12'-0" (VIF)
AutoCAD SHX Text
AutoCAD SHX Text
AXXX
AutoCAD SHX Text
+/-11'-0"
20'-0" VIF
V
I F
PLANS, ELEVATIONS, AND
SECTIONS
A102
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
SCALE: AS NOTED
DATE: 03.26.2021
DRAWN: NB
APPROVED: JZ
PROJECT #: 20.01.04
SHEET NUMBER:
This drawing must not be scaled.
The general contractor shall verify all dimensions, datums and levels prior to commencement of work. All errors and omissions to be reported immediately to the architect.
Variations and modifications to work shown on these drawings shall not be carried out without written permission from the architect. This drawing is the exclusive property of the architects and can be reproduced only with the permission of the architects, in which case the reproduction must bear their name as architects.
2021 845 Design Group P.C.©
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
SCHAUMBURG WELL #15
ROOF REPLACEMENT
325 WISE ROAD
SCHAUMBURG, IL 60193
# date description
3/26/2021 ISSUE FOR BID/PERMIT
STRUCTURAL ENGINEERS
McCLUSKEY ENGINEERING
CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335 ■ FAX: 630-717-5397
c MEC JOB #:
mec
STRUCTURAL CONSULTANT
ISSUE FOR BID AND PERMIT
SCALE: 1/4" = 1'-0"
FLOOR PLAN
SCALE: 1/4" = 1'-0"
ROOF PLAN
SCALE: 1/4" = 1'-0"
SECTION AT ROOF HATCH/WALL OPENING
SCALE: 1/4" = 1'-0"
SOUTH ELEVATION
SCALE: 1/4" = 1'-0"
SECTION AT TYPICAL WALL FRAMING
SCALE: 1/4" = 1'-0"
NORTH ELEVATION
SCALE: 1/4" = 1'-0"
WEST ELEVATION (EAST OPP)
ARCHITECTURAL SYMBOL LEGEND
GENERAL ARCH NOTES
ARCHITECTURAL KEYNOTES
KEYNOTE DESIGNATION
SECTION TAG
ELEVATION TAG
1. EXISTING CONSTRUCTION AND EQUIPMENT TO BE PROTECTED AT ALL TIMES.
2. PAINTING CONTRACTOR SHALL LABEL ALL AREAS AND MATERIALS IN ACCORDANCE
WITH SPECIFICATION.
3. CONSTRUCTION AND INSTALLATION SHALL CONFORM TO ALL STATE AND LOCAL
ORDINANCES AND CODES.
4. CONTRACTORS ARE REQUIRED TO COORDINATE THEIR RESPECTIVE WORK WITH ALL
OTHER DISCIPLINES TO AVOID ANY CONFLICTS DURING CONSTRUCTION. IT IS THE
CONTRACTOR'S RESPONSIBILITY TO COORDINATE THE ARCHITECTURAL DRAWINGS
WITH ALL OTHER CONSTRUCTION DOCUMENTS.
5. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
6. CONTRACTORS ARE REQUIRED TO VERIFY EXISTING CONDITIONS PRIOR TO ANY
FABRICATION OR CONSTRUCTION. IF EXISTING CONDITIONS ARE DIFFERENT THAN
SHOWN, NOTIFY ARCHITECTS AND/OR ENGINEERS IMMEDIATELY.
7. THE CONTRACT DOCUMENTS REPRESENT THE FINISHED DESIGN INTENT AND DO
NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE
ALL MEASURES NECESSARY TO PROJECT NEW AND EXISTING WORK DURING
CONSTRUCTION. THE ARCHITECT AND/OR ENGINEER IS NOT RESPONSIBLE FOR THE
CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES AND/OR SAFETY
PROCEDURES DURING CONSTRUCTION.
8. CONTRACTOR SHALL PROVIDE ANY NECESSARY BLOCKING FOR WALL MOUNTED
ITEMS, INCLUDING O.F.O.I. ITEMS.
FLOOR DRAIN, REFER TO PLUMBING DWGS.
DETAIL CALL OUT TAG
2-1/2" THICK INSULATED METAL PANEL - DARK BRONZE TO MATCH
ADJACENT WELL BUILDING. 4" FLUTED FACE. 'METL SPAN' CF FLUTED
OR EQ. ATTACH VIA 'Z' CLIP SYSTEM OR PER MANUFACTURER
RECOMMENDATION
NEW CUSTOM ROOF SCUTTLE - SEE STRUCTURAL DRAWINGS AND
ARCHITECTURAL DETAILS
BREAK METAL FLASHING TO MATCH NEW METAL PANELS -
PERIMETER SEALED IN PLACE - SEE DETAILS FOR INFORMATION
CUSTOM FABRICATED "REMOVABLE TRANSOM" - SEE STRUCTURAL
DRAWINGS AND DETAILS FOR MORE INFORMATION
NEW PREFINISHED GUTTER TO MATCH NEW METAL PANELS - MATCH
EXISTING SIZE - VIF
NEW DOWN SPOUTS TO MATCH NEW METAL PANELS AND GUTTERS -
MATCH EXISTING SIZE - VIF PROVIDE SPLASH PAD (x2)
EXISTING BRICK AND CMU TO REMAIN - CM TO GROUT JAMBS SOLID
AS REQ'D FOR STRUCTURAL WORK
NEW INSULATED DBL STEEL DOOR, PTD. TO MATCH NEW METAL
PANELS - SEE A400 FOR HARDWARE
EXISTING MECH RELOCATED ON NEW CURB - TIE BACK INTO
ELECTRICAL AND GAS AS NEEDED PROVIDE MINIMUM 8" FLASHING
WITH NEW CURB.
EXISTING TRANSFORMER TO REMAIN - PROTECT DURING
CONSTRUCTION AS REQ'D
EXISTING LIGHTING TO BE REINSTALLED ON UNDERSIDE OF CEILING
PROVIDE BLOCKING AS REQ'D
EXISTING FIREALARM COMPONENTS TO BE REINSTALLED ON
CEILING-PROVIDE BLOCKING AS REQ'D
EXISTING CEILING MOUNTED GAS HEATER TO BE REINSTALLED ON
CEILING - PROVIDE BLOCKING AND/OR UNISTRUT AS REQ'D
UNDERSIDE OF CEILING AND CURB FACES TO HAVE NEW WHITE
FRP/PLYWOOD BACKED PANELS AND SEAMS.
TOUCH UP CMU WALL PAINT P-3 AS REQ'D - MATCH EXISTING
PERMITER WOOD TRIM AS CEILING - SALVAGE EXISTING OR
PROVIDE NEW - PAINT WHITE P-2
NEW PREFINISHED 6" GUTTER WITH 4" DOWN SPOUTS - SEE
SECTION DETAILS
PAINT EXISTING DOOR AND FRAME TO MATCH NEW DOOR AND
FRAME P -3
AutoCAD SHX Text A102
AutoCAD SHX Text
7 OPP
AutoCAD SHX Text A102
AutoCAD SHX Text
AutoCAD SHX Text A102
AutoCAD SHX Text
AutoCAD SHX Text A102
AutoCAD SHX Text
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
SLOPE 14" / 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A400
AutoCAD SHX Text
SLOPE 14" / 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ EXIST. CONC. SLAB
AutoCAD SHX Text
EL: +0'-0"
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text 2c
AutoCAD SHX Text A400
AutoCAD SHX Text 2a
AutoCAD SHX Text A400
AutoCAD SHX Text 2b
AutoCAD SHX Text A400
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ CONCRETE SLAB
AutoCAD SHX Text
EL: +0'-0"
AutoCAD SHX Text
T/ MASONRY
AutoCAD SHX Text
EL: +12'-0" (VIF)
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ CONCRETE SLAB
AutoCAD SHX Text
EL: +0'-0"
AutoCAD SHX Text
T/ MASONRY
AutoCAD SHX Text
EL: +12'-8" (VIF)
AutoCAD SHX Text
T/ SCUTTLE CURB (H.P.)
AutoCAD SHX Text
EL: +14'-11-1/2" (VIF)
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ CONCRETE SLAB
AutoCAD SHX Text
EL: +0'-0"
AutoCAD SHX Text
T/ MASONRY
AutoCAD SHX Text
EL: +12'-8" (VIF)
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ MASONRY
AutoCAD SHX Text
EL: +12'-0" (VIF)
AutoCAD SHX Text
T/ BLOCKING (H.P.)
AutoCAD SHX Text
EL: +14'-3" (VIF)
AutoCAD SHX Text
AutoCAD SHX Text A300
AutoCAD SHX Text
AutoCAD SHX Text
AXXX
AutoCAD SHX Text
AutoCAD SHX Text
AXXX
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F.D.
AutoCAD SHX Text
AXXX
SECTION NOTES
GENERAL NOTES
WALL SECTIONS AND DETAILS
A300
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
SCALE: AS NOTED
DATE: 03.26.2021
DRAWN: NB
APPROVED: JZ
PROJECT #: 20.01.04
SHEET NUMBER:
This drawing must not be scaled.
The general contractor shall verify all dimensions, datums and levels prior to commencement of work. All errors and omissions to be reported immediately to the architect.
Variations and modifications to work shown on these drawings shall not be carried out without written permission from the architect. This drawing is the exclusive property of the architects and can be reproduced only with the permission of the architects, in which case the reproduction must bear their name as architects.
2021 845 Design Group P.C.©
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
SCHAUMBURG WELL #15
ROOF REPLACEMENT
325 WISE ROAD
SCHAUMBURG, IL 60193
# date description
3/26/2021 ISSUE FOR BID/PERMIT
STRUCTURAL ENGINEERS
McCLUSKEY ENGINEERING
CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335 ■ FAX: 630-717-5397
c MEC JOB #:
mec
STRUCTURAL CONSULTANT
ISSUE FOR BID AND PERMIT
SCALE: 1-1/2" = 1'-0"
SECTION AT CUSTOM PANEL/CURB, HATCH
SCALE: 1-1/2" = 1'-0"
SECTION AT METAL PANEL CLADDING
SCALE: 1-1/2" = 1'-0"
SECTION AT METAL PANEL CLADDING/MECH CURB
AutoCAD SHX Text
T/ GRAVEL STOP (H.P.)
AutoCAD SHX Text
EL: +14'-3" VIF
AutoCAD SHX Text
T/ MASONRY (BEYOND)
AutoCAD SHX Text
EL: +12'-8"
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text C
AutoCAD SHX Text
T/ SCUTTLE CURB
AutoCAD SHX Text
EL: +14'-11-1/2"
AutoCAD SHX Text
T/ MASONRY (BEYOND)
AutoCAD SHX Text
EL: +12'-8"
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +8'-4"
AutoCAD SHX Text
T/ SCUTTLE H.P.
AutoCAD SHX Text
EL: +16'-0"
AutoCAD SHX Text B
AutoCAD SHX Text D
AutoCAD SHX Text
T/ MASONRY
AutoCAD SHX Text
EL: +12'-0" VIF
AutoCAD SHX Text
B/ METAL PANEL
AutoCAD SHX Text
EL: +12'-0" VIF
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
1. SHEET NOTES APPLY TO A300 SERIES SHEETS. NOT ALL SHEET NOTES LISTED BELOW ARE USED ON EACH SHEET
AutoCAD SHX Text A ROOF ASSEMBLY, (R-30 MIN.) ROOF ASSEMBLY, (R-30 MIN.)ROOF ASSEMBLY, (R-30 MIN.)
AutoCAD SHX Text FULLY ADHERED WHITE EPDM MEMBRANE 14" OVERLAYMENT BOARD 5" RIGID POLYISO INSULATION (MIN. R-30) 6 MIL POLY VAPOR BARRIER 34" EXTERIOR PLYWOOD DECK - SEE STRUCTURAL WOOD JOISTS (2 x 12 V.IF.) - SEE STRUCTURAL BATT INSULATION 58" PLYWOOD SHEATHING, PTD. TYP
AutoCAD SHX Text
D 'REMOVABLE TRANSOM PANEL" 'REMOVABLE TRANSOM PANEL"'REMOVABLE TRANSOM PANEL"
AutoCAD SHX Text 2-1/2" CORRUGATED INSULATED METAL PANEL (R-17) FURRING/FASTENING SYSTEM PER MANUFACTURER AIR/WEATHER BARRIER (2 LAYERS) 3/4" EXTERIOR SHEATHING- (DENSGLASS OR APPROVED EQ.) (DENSGLASS OR APPROVED EQ.) INFILL 2x4 WOOD STUD FRAMING AT 16" OC (INSIDE STEEL FRAME) BATT INSULATION IN STUD CAVITY (MIN. R-11) 5/8" STRUCTURAL FRP W/ PLYWOOD BACKING (SEE SPEC)
AutoCAD SHX Text 1 GALVANIZED PICK POINT EYE HOOKS. SLEEVE AND SEAL GALVANIZED PICK POINT EYE HOOKS. SLEEVE AND SEAL 3" INSIDE DIAMETER. PROVIDE BLOCKING AS NEEDED
AutoCAD SHX Text 2 GRAVEL STOP - FASTEN, SEAL & FLASH AT PER MANUF. SPEC. DETAILSGRAVEL STOP - FASTEN, SEAL & FLASH AT PER MANUF. SPEC. DETAILSFOR SPECIFIED ROOFING SYSTEM
AutoCAD SHX Text
3 BLOCKING PER ROOF MANUF. SPECIFICATIONSBLOCKING PER ROOF MANUF. SPECIFICATIONS
AutoCAD SHX Text 4 PRE-FIN. ALUM. FASCIA TRIM WITH DRIP. FASTEN W/ CONTINUOUS CLEAT PRE-FIN. ALUM. FASCIA TRIM WITH DRIP. FASTEN W/ CONTINUOUS CLEAT PER MANUF. SPECS
AutoCAD SHX Text 5 ROOF SCUTTLE CURB WALL - 3 SIDES + REMOVABLE TRANSOM ROOF SCUTTLE CURB WALL - 3 SIDES + REMOVABLE TRANSOM
AutoCAD SHX Text
6 RECESSED AND CONCEALED "PICK POINT" X 2RECESSED AND CONCEALED "PICK POINT" X 2
AutoCAD SHX Text 7 "REMOVABLE" METAL FLASHING 16 GA - LAP OVER TRANSOM AND SIDE "REMOVABLE" METAL FLASHING 16 GA - LAP OVER TRANSOM AND SIDE WALL CURB FACE - SEAL AT EDGES - TO BE CUT LOOSE IN FUTURE
AutoCAD SHX Text 8 NEW TREATED PERIMETER RIM JOIST AND ROOF FRAMING - SEE STRUCT.NEW TREATED PERIMETER RIM JOIST AND ROOF FRAMING - SEE STRUCT.
AutoCAD SHX Text
9 FLASHING W/ DRIP EDGEFLASHING W/ DRIP EDGE
AutoCAD SHX Text
10 FURRING AS REQ'D FURRING AS REQ'D
AutoCAD SHX Text 14 NEW 6" PRE-FINISHED ALUM. GUTTER. MATCH PROFILE & SIZE NEW 6" PRE-FINISHED ALUM. GUTTER. MATCH PROFILE & SIZE OF WELL HOUSE #12 (V.I.F.)
AutoCAD SHX Text
13 REMOVABLE DOOR HEADER - SEE A400 REMOVABLE DOOR HEADER - SEE A400
AutoCAD SHX Text 11 CONTINUOUS MECHANICALLY FASTENED GASKET SEAL - SEE A400 CONTINUOUS MECHANICALLY FASTENED GASKET SEAL - SEE A400
AutoCAD SHX Text 12 T/ CURB ADHERE 3M COMPRESSIBLE FOAM TAPE 4504 OR EQ T/ CURB ADHERE 3M COMPRESSIBLE FOAM TAPE 4504 OR EQT/ CURB ADHERE 3M COMPRESSIBLE FOAM TAPE 4504 OR EQ
AutoCAD SHX Text
C EXISTING MASONRY WALL - NEW METAL PANELEXISTING MASONRY WALL - NEW METAL PANEL
AutoCAD SHX Text 2-1/2"" CORRUGATED INSULATED METAL PANEL 7/8" FURRING STRIPS EXISTING 4" BRICK EXISTING 4" CMU
AutoCAD SHX Text
B ROOF SCUTTLE, (R-30 MIN.) ROOF SCUTTLE, (R-30 MIN.)ROOF SCUTTLE, (R-30 MIN.)
AutoCAD SHX Text
(4) EXPOSED GALVANIZED/ZINC TREATED EYE HOOK PICK POINTS EXPOSED GALVANIZED/ZINC TREATED EYE HOOK PICK POINTS FULLY ADHERED WHITE EPDM MEMBRANE 14" OVERLAYMENT BOARD 1.5" RIGID INSULATION (MIN. R-7) 6 MIL POLY VAPOR BARRIER 34" EXTERIOR PLYWOOD DECK - SEE STRUCTURAL WOOD JOISTS @ 16" O.C. (2 X 8) SEE STRUCTURAL 8" CAVITY INFILL BATT INSULATION (MIN R-23) 58" STRUCTURAL FRP W/ PLYWOOD BACKING (SEE SPEC)
AutoCAD SHX Text 15 REMOVABLE STEEL NUTS AND BOLT ON ANGLE SUPPORTS - SEE REMOVABLE STEEL NUTS AND BOLT ON ANGLE SUPPORTS - SEE STRUCTURAL DRAWINGS
AutoCAD SHX Text 16 CEILING AND INSIDE CURB FACE TO BE FRP/PLYWOOD PANELS, TYP CEILING AND INSIDE CURB FACE TO BE FRP/PLYWOOD PANELS, TYP
AutoCAD SHX Text 17 NEW MECHANICAL CURB - MIN 14" VERIFY COMPATIBLE WITH EXISTING NEW MECHANICAL CURB - MIN 14" VERIFY COMPATIBLE WITH EXISTING HOOD TO BE REUSE
AutoCAD SHX Text
18 DOWN SPOUT - SEE ELEVATION DOWN SPOUT - SEE ELEVATION
AutoCAD SHX Text 19 PANEL BASE ENCLOSURE TRIM PER MANUFACTURER PANEL BASE ENCLOSURE TRIM PER MANUFACTURER
20 REINSTALL EXISTING MECHANICAL EQUIPMENT REINSTALL EXISTING MECHANICAL EQUIPMENT
(8) EA HINGE 5BB1 4.5 x 4.5 652 IVES
(4) EA FLUSH BOLT FB45826 652 IVES
(4) EA DP STRIKE DP226 652 IVES
(1) EA PULL PLATE 8303 10" 4" X 16" G 652 IVES
(1) EA ASTRAGAL
(1) EA GASKETING 488S-BK
(2) EA KICKPLATE
(2) EA DOOR SWEEP G1367597
(1) EA WEATHER STRIPPING
(1) EA THRESHOLD
QTY DESCRIPTION PART NUMBER FINISH MFR
DOOR HARDWARE
GROUT EXISTING CMU OR
TOOTH/REPLACE CMU TO GROUTED
SOLID - SEE STRUCTURAL
REMOVABLE DOOR HEADER W/
ENCLOSED WELDED FACE PLATES
BOTH SIDES - PROVIDE ACCESSIBLE
MECHANICALLY SECURED 'L' BRACKETS
AT UNDERSIDE , PTD - PROVIDE 3M
VINYL FOAM TAPE AT DOOR HEAD BUTT
JOINTS TO JAMB
CMU MOUNTED STEEL ANGLE - SEE
STRUCTURAL DWGS. STEEL PAINTED,
TYP.
ACCESSIBLE/REMOVABLE BOLT
HARDWARE TO REMOVE TRANSOM
PANEL
PROVIDE 3M VINYL FOAM TAPE 4504
OR EQUAL AT VERTICAL AND
HORIZONTAL JOINTS
MECHANICALLY FASTENED
CONTINUOUS PERIMETER GASKET -
LEGACY 5584 OR EQUAL
METAL PANEL 'h' OR "J' TRIM - ALLOW
FOR TRANSOM PANEL REMOVAL
REMOVABLE TRANSOM PANEL
SEE SECTION INFORMATION ON
A300
ANCHOR AND GROUT NEW DOOR
JAMBS SOLID AS REQ'D
2c - PLAN DETAIL AT TRANSOM
2b - PLAN DETAIL AT HEAD
2a - PLAN DETAIL AT JAMB
PROVIDE REMOVABLE BREAK METAL FLASHING WITH PERIMETER SEALANT.
SEALANT SHALL BE CUTTABLE AND SACRIFICIAL FROM EDGES TO REMOVE FLASHING.
THIS SEALANT SHALL BE WATER TESTED BY CONTRACTOR AFTER INSTALL.
NOTE: AT ANY FUTURE POINT, WHEN THE VILLAGE OR ANY VILLAGE CONTRACTED WORKER
CUTS THE FLASHING SEALANT TO REMOVE THE TRANSOM PANEL. THE WARRANTY OF THE
SEALANT WORK UNDER THIS SCOPE OF WORK SHALL BE VOIDED.
BELOW ROOF SCUTTLE - AT OUTSIDE
FACE OF TRANSOM PANEL PROVIDE 3M
VINYL FOAM TAPE 4504
OR EQUAL AT VERTICAL BUTT JOINTS
+/- 8'-4" TRANSOM PANEL / PARAPET
+/- 5
+/- 5
+/- 2"
+/- 2"
+/- 9'-4
PICK POINTS FOR SCUTTLE - SEE
STRUCTURAL DRAWINGS
CONCEALED AND RECESSED TRANSOM
PICK POINTS
7 8
+/- 9'-8
"VIF
CONTINUOUS PERIMETER BLOCKING
AND GRAVEL STOP WITH DRIP EDGE -
SEE SECTIONS A300
DASHED LINE INDICATES ROOF
SCUTTLE CURB BELOW
+/- 8'-5"VIF MASONRY OPENING
S L
O P
E
ENLARGED PLAN DETAILS
A400
106 Calendar Court, No. 131 LaGrange, Illinois 60525 phone: 708.218.9974 www.845designgroup.com
SCALE: AS NOTED
DATE: 03.26.2021
DRAWN: NB
APPROVED: JZ
PROJECT #: 20.01.04
SHEET NUMBER:
This drawing must not be scaled.
The general contractor shall verify all dimensions, datums and levels prior to commencement of work. All errors and omissions to be reported immediately to the architect.
Variations and modifications to work shown on these drawings shall not be carried out without written permission from the architect. This drawing is the exclusive property of the architects and can be reproduced only with the permission of the architects, in which case the reproduction must bear their name as architects.
2021 845 Design Group P.C.©
Illinois professional design firm#184.006583
DESIGN
GROUP
Architecture
Planning+
SCHAUMBURG WELL #15
ROOF REPLACEMENT
325 WISE ROAD
SCHAUMBURG, IL 60193
# date description
3/26/2021 ISSUE FOR BID/PERMIT
STRUCTURAL ENGINEERS
McCLUSKEY ENGINEERING
CORPORATION
1887 HIGH GROVE LANE
NAPERVILLE, ILLINOIS 60540
630-717-5335 ■ FAX: 630-717-5397
c MEC JOB #:
mec
STRUCTURAL CONSULTANT
ISSUE FOR BID AND PERMIT
SCALE: 1-1/2" = 1'-0"
PLAN DETAILS AT SOUTH ELEVATION INFILL
SCALE: 1-1/2" = 1'-0"
PLAN DETAIL ROOF CURB
File details come from the government source that posted it. Updated .