WCC-L22WC154 Project Drawings 2024-03-08.pdf

PDF 4 MB Posted

Attached to
Overhead Lineman Yard at Wytheville Community College, PC# L22WC154
Solicitation number
71038
Issued by
Wise County, Virginia

About this file

This document contains project drawings for the construction of a new overhead lineman yard at Wytheville Community College in Wytheville, Virginia. The project is described as the development of an overhead lineman yard, and sealed bids are being solicited by the Virginia Community College System. The bid due date is 2:00 P.M. on Tuesday, August 6, 2024, with the bids to be opened publicly and read aloud the following day. A pre-bid conference is scheduled for 11:00 A.M. on Monday, July 15, 2024 at the college, and attendance is highly recommended for bidders. The project will require a Standard Commonwealth Bid Bond (form CO-10.2) and Contract Security, regardless of the bid amount. The bidder must be a registered vendor in eVA.

The drawings provide details on the site plan, concrete pad construction, gravel and mulch areas, and related site elements. No additional parking is being created as part of this project. The proposed disturbed area is less than 10,000 square feet, making the project exempt from erosion and sediment control and stormwater management requirements under the VCCS standards.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet No.

Designed

Drawn

Checked

Date

Project No.

N o.

Da te

Pu rp os e of D oc um en t I ss ue

Seal

STATE BUILDING OFFICIAL APPROVAL STAMP

PROJECT NO: 16811

MARCH 8, 2024

WYTHEVILLE, VIRGINIA

VIRGINIA COMMUNITY COLLEGE SYSTEM

WYTHEVILLE COMMUNITY COLLEGE

PROJECT CODE: L22WC154

PREPARED FOR

FRANKFORT

CHATTANOOGA

VICINITY MAP

TENNESSEE

NASHVILLE

N

KENTUCKY

CHRISTIANSBURG

TAZEWELL

NORTH CAROLINA

ASHEVILLE

KNOXVILLE

BRISTOL

CHARLOTTE

RADFORD

RALEIGH

VIRGINIA

CHARLESTON

LEXINGTON

PRINCETON

BLUEFIELD

VIRGINIA

WEST

WASHINGTON

RICHMOND

D.C.

LOCATION MAP

SCALE: 1" = 1,000'

SOURCE: GOOGLE EARTH IMAGE

726 Auburn Avenue Radford, Virginia 24141

P: (540) 633-1897 F: (540) 633-1896 www.T-L.com

E S T . 1 9 5 6

LITTON&

THOMPSON

PROJECT LOCATION

GALAX

SHEET INDEX

T100 TITLE SHEET

C100 SITE PLAN

PROJECT LOCATION

I 81

I 81

I 81

COMMUNITY BLVD

PEPPERS FERRY ROAD

I 77

I 77

COLLEGE CIRCLE

CASSELL RD

PE

PP

ER

S

FE

RR

Y

RO

AD

NYE ROAD

GENERAL NOTES

1. VERTICAL CONTROL IS BASED ON NAVD 1988 DATUM.

2. HORIZONTAL CONTROL IS BASED UPON THE VIRGINIA STATE PLANE COORDINATE SYSTEM, NORTH ZONE (NAD 83).

3. THE EXISTENCE AND LOCATION OF EXISTING UTILITIES ARE NOT GUARANTEED AND SHALL BE INVESTIGATED AND FIELD VERIFIED BY THE CONTRACTOR BEFORE STARTING WORK. ANY DAMAGE DONE TO EXISTING UNDERGROUND UTILITIES AND FACILITIES SHALL BE REPAIRED WITH THE UTILITIES AND FACILITIES RESTORED TO AT LEAST THEIR ORIGINAL CONDITION. THE CONTRACTOR SHALL

BEAR ALL COSTS ASSOCIATED WITH THESE REPAIRS.

4. THE CONTRACTOR SHALL CONTACT "MISS UTILITY OF VIRGINIA" 72 HOURS BEFORE ANY EXCAVATION WORK IS BEGUN. "MISS

UTILITY OF VIRGINIA" MAY BE REACHED AT 1-800-552-7001.

5. ALL SPOT ELEVATIONS ARE INTENDED FOR FINAL GRADE.

6. ALL UNPAVED AND UNGRAVELED AREAS DISTURBED BY EXCAVATION SHALL BE STABILIZED IN ACCORDANCE WITH THE PROJECT

DOCUMENTS.

7. THIS PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE VIRGINIA DEPARTMENT OF TRANSPORTATION'S ROAD AND BRIDGE SPECIFICATIONS AND ROAD AND BRIDGE STANDARDS AS APPLICABLE.

8. THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS DETAILED IN THE VIRGINIA EROSION & SEDIMENT CONTROL HANDBOOK AND THE VIRGINIA STORMWATER DESIGN SPECIFICATIONS FOR EROSION AND SEDIMENT CONTROL AND STORMWATER MANAGEMENT, LATEST VERSION.

9. THE CONTRACTOR/OWNER SHALL BE RESPONSIBLE FOR ACQUIRING ALL REQUIRED CONSTRUCTION PERMITS AND BONDS PRIOR TO

CONSTRUCTION.

10. THE CONTRACTOR AND RESPONSIBLE LAND DISTURBER SHALL BE RESPONSIBLE FOR ACCURATELY DOCUMENTING AND MAINTAINING ANY CHANGES TO THESE APPROVED PLANS IN THE FIELD DURING CONSTRUCTION. THESE CHANGES MUST BE UTILIZED DURING THE RECORD DRAWING PROCESS. ANY CHANGE SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND

APPROVAL.

11. PER VCCS ANNUAL STANDARDS AND SPECIFICATIONS PAGE 10, VCCS ANNUAL STANDARDS AND SPECIFICATIONS FOR ESC APPLY IF LAND DISTURBANCE ACTIVITY EQUAL TO OR GREATER THAN 10,000 SF. PER VCCS ANNUAL STANDARDS AND SPECIFICATIONS PAGE 11, VCCS ANNUAL STANDARDS AND SPECIFICATIONS FOR SWM APPLY IF LAND DISTURBANCE ACTIVITY IS EQUAL OR GREATER TO 1 AC. THE PROPOSED DISTURBED AREA SHALL BE 9,700 SF AND THUS MAKING THIS PROJECT EXEMPT FROM SWM AND ESC

REQUIREMENTS.

DEMOLITION NOTES

1. ALL MATERIAL OR DEBRIS REMOVED FROM THE SITE BY THE CONTRACTOR SHALL BE LEGALLY DISPOSED OF

BY THE CONTRACTOR.

2. IF MATERIALS, DEBRIS, OR ANY OTHER ADDITIONAL DEMOLITION APPURTENANT TO THE SITE PLAN, BUT NOT DEPICTED WITHIN THE PLAN IS FOUND TO INTERFERE WITH CONSTRUCTION ACTIVITIES WITHIN THE LIMITS OF DISTURBANCE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, DEMOLITION, AND DISPOSAL OF SAID MATERIAL, DEBRIS, ETC. SOME DEMOLITION ITEMS MAY NOT BE ILLUSTRATED ON THE PLANS. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE VISIT THE SITE AND DETERMINE THE FULL EXTENT OF THE REQUIRED DEMOLITION. THE CONTRACTOR SHALL PROVIDE DOCUMENTATION TO THE ENGINEER AND OWNER ON ITEMS LOCATED THAT MAY REQUIRE ADDITIONAL DEMOLITION OR

REMOVAL.

WYTHEVILLE COMMUNITY COLLEGE

OVERHEAD LINEMAN YARD

NG

IN

E E

AI

NI

GR

IV

N

EW

FOHTLA

R

N LA E

SSIO

FE

O C

P R

M O

O

M

03-08-2024

16811

ESD

ESD

T001

W

YT

HE

VI

LL

E

CO

M

M U

N

IT

Y

CO

LL

EG

E O

VE

RH

EA

D

LI

N

EM

AN

Y

AR

D W

YT

HE

VI

LL

E, V

IR

GI

N

IA

TI

TL

E

SH

EE

T

PROJECT DESCRIPTION

THE PROJECT CONSISTS OF THE CONSTRUCTION OF A NEW OVERHEAD LINEMAN YARD

POINT OF CONTACT

WYTHEVILLE COMMUNITY COLLEGE

PROJECT MANAGER: JOSEPH COLLINS

P: 276-613-4461

WYTHEVILLE COMMUNITY COLLEGE

1000 E MAIN ST, WYTHEVILLE, VA 24382

DIG NOTICE

CONTACT VIRGINIA 811 AT 811, 1-800-552-7001, OR https://www.va811.com NO LESS THAN 72 HOURS PRIOR TO EXCAVATION AND DO

NOT DISTURB THE SOIL UNTIL DIG TICKET HAS BEEN PROCESSED

CODE INFORMATION

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN, DATED SEPTEMBER 15, 2010 AND CHAPTERS 1&3 THRU 11 OF STANDARDS FOR ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC A117.1-2017) APPROVED MARCH 28, 2017.

2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF VIRGINIA UNIFORM STATE WIDE BUILDING CODE (USBC)

Seal

ISSUED FOR BID

S

S

S

S

S

S

S

S

S

S

S

S S

S

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

OHU

STORM

DISTORM

DI

UP

UP

UP

O

HE

O

HE

O

HE

O

HE

O

HE

O

HE

O

HE

LPLP

VDOT COMM.

VAULT

PA

VE

D W

AL

K

PA

VE

D W

AL

K

SO

IL

T

RA

IL

UP

COMMUNITY BLVD.

+/- 420' TO CASSELL RD.

STMH

STMH

STMH

GRASS AREA

GRASS AREA

GRASS AREA

SCATTERED TREES

AND BRUSH

SCATTERED TREES

AND BRUSH

CONC. WALK

" H

DP

E

24" HDPE

24" HDPE

24" HDPE

CREEKCREEK

LO

D

LO

D

LO

D

LO

D

LO

D

LO

D

LODLODLOD

LOD

LO

D

LO

D

LO

D

LOD LOD LOD

X X

X X

X X X X X

X X X

X

1" =

( IN FEET )

GRAPHIC SCALE

040' 40' 80'

40'

20'

NOTES:

1) CONTRACTOR SHALL BRUSH HOG AND MOW THE AREA TO BE

MULCHED PRIOR TO PLACEMENT OF GEOTEXTILE .

2) CONTRACTOR SHALL REMOVE DEBRIS SUCH AS ROCKS, TREE

LIMBS, AND ANY OTHER MATERIAL THAT COULD COMPROMISE

THE INTERGRITY OF THE GEOTEXTILE.

3) KEY IN GEOTEXTILE FABRIC AT THE PERIMETER OF THE

LINEMAN YARD.

4) GEOTEXTILE FABRIC SHALL BE OVERLAPPED A MINIMUM OF 6"

AT EDGES AND 12" AT ENDS.

5) STAPLES SHALL BE UTILIZED TO SECURE GEOTEXTILE IN PLACE

PRIOR TO MULCH PLACEMENT.

6) ENGINEER SHALL PROVIDE DWG FILE TO CONTRACTOR FOR

STAKING.

7) NO ADDITIONAL PARKING IS BEING CREATED.

8) PROPOSED EXPANSION OF GRAVEL AREA IS FOR STORAGE

CONTOUR INTERVAL = 1'

SI

TE

P

LA

N

03-08-2024

16811

ESD

C100

TYPICAL DETAIL - GRAVEL AREA

CONTOUR2228

LOD

OHE

LEGEND

NEW DESCRIPTIONEXISTING

CONCRETE

STORM PIPE

STORM STRUCTURE

OVERHEAD ELECTRICAL

ELECTRICAL BOX/HANDHOLE

LIMITS OF DISTURBANCE

MULCH

SEWER PIPE

SEWER STRUCTURE

S

LIGHT POLE

GRAVEL

TYPICAL DETAIL - MULCH AREA

OHU OVERHEAD UTILITY

NOTES:

1) PRIOR TO PLACEMENT OF AGGREGATE CONTRACTOR SHALL

STRIP TOPSOIL AND REMOVE FROM THE SITE.

W

YT

HE

VI

LL

E, V

IR

GI

N

IA

W

YT

HE

VI

LL

E

CO

M

M U

N

IT

Y

CO

LL

EG

E O

VE

RH

EA

D

LI

N

EM

AN

Y

AR

D

SILT FENCE

18"

12"

8.5"

MIN.

2" C

LR

#4@12 EW, BOT.2#4 (TYP.)

#4@12 EW, TOP

ASTM-A615

CONCRETE SLAB-ON-GRADE

5,000 PSI CONCRETE @ 28 DAYS

TYPICAL SECTION - CONCRETE PAD

NOT TO SCALE

TYPICAL HANDICAP PARKING STALL LAYOUT

TYPICAL DETAIL - CURB STOP

X X

Sheet No.

Designed

Drawn

Checked

Date

Project No.

N o.

Da te

Pu rp os e of D oc um en t I ss ue

Seal

STATE BUILDING OFFICIAL APPROVAL STAMP

SealSeal

Sheets and Views
T001 SHEET TITLE
C100 SITE PLAN

File details come from the government source that posted it. Updated .