Waukazoo Drawings.pdf

PDF 27 MB Posted

Attached to
ELEMENTARY IMPROVEMENTS
Solicitation number
RFP-WOP-250000003178-4
Issued by
Saginaw County, Michigan

About this file

This file contains architectural drawings for the Waukazoo Elementary School Improvements project located in Holland, Michigan for West Ottawa Public Schools, dated 2025. The drawings specifically show demolition and first floor plans for three building units (A, B, and C).

The architectural drawings include detailed floor plans with room layouts, demolition notes, wall legends, and general floor plan notes. Key details include comprehensive room numbering and designations such as classrooms, toilets, mechanical rooms, corridors, storage areas, and administrative spaces. The plans indicate proposed wall removals, window and door modifications, and overall spatial reorganization of the school's interior. The documents appear to be part of a significant renovation project covering multiple building units, with precise architectural specifications for demolition and reconstruction of interior spaces.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TT

T

T

T

T

T

T

T

BF

BF

BFBF

BF

BF

BF

BF

BF

R. DW REF.

BFBF

BF BF

BF

BF

BF

BF

BF BF BF BF

BF

BF

BFBF

BF BF

BFBF

BFBF

BFBF BF

BFBF

BFBFBF

BF

BF

BF

BF

BF

BF

BFBF

BF

BF

BF

BF

BF

R.BF

A4.01

CLASSROOM

C101

CLASSROOM

C105

CLASSROOM

C106

CLASSROOM

C110

CLASSROOM

A138

CLASSROOM

B142

CLASSROOM

C167

CLASSROOM

C163

CLASSROOM

C162

CLASSROOM

C158

T.

A139

CLOSET

A140

SMALL GROUP

A141

STORAGE

B140

STORAGE

B141

T.

B139

KILN

B138

T.

C102

T.

C166

T.

C104

T.

C164

SMALL GROUP

C103

SMALL GROUP

C165

T.

C107

T.

C161

SMALL GROUP

C108

SMALL GROUP

C160

T.

C109

T.

C159

CORRIDOR

C100

CLASSROOM

C113

AIDES ROOM

C114

SPECIAL ED. ROOM

C115

WORK ROOM

C111

ELEC.

C112

CLASSROOM

C127

CLASSROOM

C131

CLASSROOM

C132

CLASSROOM

C136

CLASSROOM

C137

CLASSROOM

C141

CUSTODIAL

C142

OFFICE

C143

VESTIBULE

C144

STORAGE

C145

CLASSROOM

C146

CLASSROOM

C150

SMALL GROUP

C148

T.

C147

T.

C149

T.

C138

T.

C140

SMALL GROUP

C139

T.

C135

SMALL GROUP

C134

T.

C133

T.

C130

SMALL GROUP

C129

T.

C128

WORK ROOM

C152

STAFF PLANNING

C153

GIRLS T.

C156

T.

C157

T.

C126

BOYS T.

C155

CUSTODIAL

C154

CORRIDOR

C126

CORRIDOR

C151

CLASSROOM

A116

CLASSROOM

A119

MECHANICAL

A121

T.

A117

T.

A118

VESTIBULE

A115

CORRIDOR

A122

VESTIBULE

A123

ELEC.

A120

COMPUTER ROOM

A114

CUSTODIAL

A124

STORAGE

A125

RESOURCE

A126

CLASSROOM

A127

CLASSROOM

A130

T.

A128

T.

A129 CLASSROOM

A131

MUSIC CLASSROOM

A134T.

A132 T.

A133

BOYS T.

A135

GIRLS T.

A136

AUDIO / VISUAL

A112

MEDIA CENTER

A113

VESTIBULE

A137

CLASSROOM

B102

STORAGE

B103

OFFICE

B104

T.

B105

CLASSROOM

B107

CLASSROOM

B132STORAGE

B136

KITCHEN

B133

T.

B134

VESTIBULE

B137

CORRIDOR

B100

GIRLS T.

B108

BOYS T.

B109

READING

B110

OFFICE

B111

MULTI-PURPOSE ROOM

B130

PLATFORM

B131

STORAGE

B126

CUSTODIAL

B127

FOOD SERVICE

B128 STORAGE

B129

MECHANICAL

B112

CORRIDOR

B114

VESTIBULE

B113

VESTIBULE

B115

BOYS T.

B118

GIRLS T.

B119

STORAGE

B120

GYM OFFICE

B122

STORAGE

B123

CORRIDOR

B116

STORAGE

B124

STORAGE

B125

GYMNASIUM

B117

CORRIDOR

A142

STAFF LAB

A111

OFFICE

A105

WORK ROOM

A107

TOILET

A108

HEALTH

A109

OFFICE

A104

CONFERENCE

A103

RECEPTION

A102

VESTIBULE

A100

CORRIDOR

A101

CORRIDOR

C118

VESTIBULE

C117

STORAGE

C119

CLASSROOM

C124

CLASSROOM

C120

MECH

C125

MECH

C121

T.

C123

T.

C122

TIME AWAY

C116

A4.01

A4.01

A4.01

A4.01 4

A4.02 2

A4.02

A4.02

A4.02

A4.024

A8.01

A8.0129

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

5:

:3

PM

A0.01

5-6249

OVERALL FIRST FLOOR PLAN

ERE

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

1/16" = 1'-0"

OVERALL FIRST FLOOR PLAN

UNIT A UNIT B

UNIT C

08.28.2025 BIDS &

CONSTRUCTION

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497

CORE #1

CORE #2

CORE #3

CORE #4

CORE #5

CORE #6

CORE #7

CORE #8CORE #9 CORE #10

CORE #11

CORE #12

CORE #13

CORE #14

CORE #16

CORE #15

ROOF LADDER B

ROOF LADDER A

1" 7"

0" M

IN

3"

13' - 2"

TAPERED RIGID INSULATION (4' - 0" SECTIONS)

1/4" PER FOOT SLOPE UNLESS OTHERWISE

NOTED

DIRECTION OF ROOF SLOPE.

WITH TAPERED INSULATION

ROOF HATCH

STANDARD ROOF DRAIN

LEGEND

GENERAL NOTES

ROOF WALKWAY PAD

(SEE SPEC. FOR

MATERIAL)

TAPERED RIGID INSULATION (4' - 0" SECTIONS

@ 1/4" SLOPE PER FOOT AT CRICKETS)

CRICKETS SLOPE TO ROOF DRAINS.

DIRECTION OF STRUCTURAL

ROOF SLOPE. (SEE STRUCTURAL

PLANS FOR ROOF FRAMING

SLOPES)

ROOF DRAIN LABELRD-5-1

THICKNESS OF TAPERED INSULATION AT

PERIMETER OR DRAIN (NOT INCLUDING

BASE INSULATION THICKNESS)

+ 7 1/4"

ROOF DRAIN NUMBER

ROOF AREA (SEE ROOF KEYPLAN)

RD OR ORD

CR#1 CORE SAMPLE LOCATIONS SEE

LEGEND FOR DESCRIPTION

CORE #1 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,

1/2" WOOD FIBER BOARD, TAPERED EPS INSULATION,

3/4" FESCO, ON EXISTING METAL DECK.

CORE SAMPLE DESCRIPTION

CORE #2

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

ROOF DETAILS - LOCATED ON SHEET A7.01

ROOF DRAIN

ROOF OVERFLOW DRAIN

FASTENING ENHANCEMENT AT CORNER - SEE SPEC AND DETAIL

PLUMBING VENT

STACK FLASHING

METAL COPING SPLICE DETAIL

ROOF CURB DETAIL

RE-ROOFING EXISTING NAILERS / BLOCKING TO REMAIN:

CONTRACTOR TO FIELD VERIFY THE EXISTING NAILERS / BLOCKING

WILL COMPLY TO MEET THE WIND UP LIFT CRITERIA. REMOVE ALL

DAMAGED NAILERS / BLOCKING AND / OR INSTALL ADDITIONAL

FASTENER AS REQUIRED TO COMPLY.

REFER TO PLUMBING DRAWINGS FOR LOCATION AND NUMBER OF

PLUMBING VENTS THRU ROOF.

REFER TO MECHANICAL DRAWINGS TO COORDINATE ALL ROOF

PENETRATIONS & LOCATIONS.

PROVIDE 1/2" TAPERED CRICKETS AT ALL ROOF HATCHES AND

MECHANICAL ROOF PENETRATIONS UNLESS OTHERWISE NOTED.

TAPER SHALL PROVIDE DRAINAGE AROUND HATCH AND EQUIPMENT.

SEE SPECIFICATION FOR ROOFING SYSTEM TO BE USED AND ROOF

PLAN FOR LOCATIONS OF TAPERED INSULATION AND OR SLOPE

CHANGES OF ROOF.

CONTRACTOR RESPONSIBLE TO FIELD VERIFY ALL SQUARE

FOOTAGE VALUES NOTED ON PLANS

IN AREAS WHERE EXISTING ROOF DRAINS ARE BEING REPLACED

WITH NEW ROOF DRAIN TO BE INSTALLED IN THE EXACT LOCATION

OF EXISTING AND WILL BE CONNECTED TO EXISTING PIPING AS

REQUIRED.

SCUPPER LOCATIONS TO BE COORDINATED SO THAT THEY DO NOT

APPEAR OVER DOORS, WINDOWS OR MECHANICAL LOUVERS

STANDARD ROOF ABBREVIATIONS

RD = ROOF DRAIN

ORD = OVERFLOW ROOF DRAIN

EF = EXHAUST FAN

IV = INTAKE VENT

RTU = ROOF TOP UNIT

RV = RELIEF VENT

ST. SLOPE

SLOPE

DURALAST PVC ROOFING, EPDM MEMBRANE,

TAPERED EPS INSULATION, 3/4" FESCO, ON

EXISTING METAL DECK.

CORE #3 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,

3 1/2" POLYISOCYANURATE INSULATION, TAPERED EPS

INSULATION, 2" POLYISOCYANURATE INSULATION, ON

EXISTING METAL DECK.

CORE #4 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,

3 1/2" POLYISOCYANURATE INSULATION, ON EXISTING

METAL DECK.

CORE #5 DURALAST PVC ROOFING, 3 1/2" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #6 DURALAST PVC ROOFING, 2" POLYISOCYANURATE

INSULATION, TAPERED EPS INSULATION, DURALAST

PVC ROOFING, 2" POLYISOCYANURATE, ON EXISTING

METAL DECK.

CORE #7 DURALAST PVC ROOFING, 2" POLYISOCYANURATE

INSULATION, TAPERED EPS INSULATION, 2"

POLYISOCYANURATE, ON EXISTING METAL DECK.

CORE #8 DURALAST PVC ROOFING, 2" POLYISOCYANURATE

INSULATION, TAPERED EPS INSULATION, 2"

POLYISOCYANURATE, ON EXISTING METAL DECK.

CORE #9 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING CONCRETE DECK.

CORE #10 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #11 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #12 DURALAST PVC ROOFING, 2"

POLYISOCYANURATE INSULATION, 1/2" WOOD

FIBER BOARD, 2" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #13 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #14 DURALAST PVC ROOFING, 6" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #15 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

CORE #16 DURALAST PVC ROOFING, 4" POLYISOCYANURATE

INSULATION, ON EXISTING METAL DECK.

AREAS WHERE PARAPET

NEEDS TO BE RAISED

STEEL ANGLE FRAME

AROUND PERIMETER EXTEND

TO ROOF STRUCTURE - SEE

STRUCTURAL DRAWINGS

MEMBRANE ROOFING SYSTEM

FULLY ADHERED TO COVER

BOARD WITH ISO INSULATION

FASTENED TO METAL DECK

SEE ROOF PLAN FOR

ADDITIONAL NOTES

EXTEND ROOF MEMBRANE

UP & OVER CURB

PRE-FABRICATED

INSULATED ROOF CURB

PROVIDE AT BALLASTED ROOF

AREAS ONLY - VAPOR BARRIER

TO RUN UP CURB & BE SEALED

TO INSIDE FACE OF CURB.

EQUIPMENT HOUSING OR

FLASHING - SEE

MECHANICAL DRAWINGS

TREATED 2x WOOD BLOCKING

AS REQUIRED AROUND CURB

OPENING PERIMETER

MI

N.8"

ROOF DRAIN WITH CAST

GRATING (NO PLASTIC

ALLOWED)

MEMBRANE ROOFING

SYSTEM FULLY ADHERED

TO 1/2" COVER BOARD WITH

ISO INSULATION FASTENED

TO METAL DECK SEE ROOF

PLAN FOR ADDITIONAL

NOTES

METAL DECK - SEE

STRUCTURAL DRAWINGS

STEEL ANGLES - SEE

STRUCTURAL DRAWINGS

INSTALL INSULATION

UNDER DRAINS

DRAIN PIPE WITH INSULATION -

SEE PLUMBING DRAWINGS

DRAIN SUMP PAN

INSTALL 4'-0" x 4'-0" 1/2"

PER FOOT SLOPE PREFAB

INSULATED DRAINSET AT

EACH ROOF DRAIN TO

PROVIDE POSITIVE SLOPE

TO DRAIN

OVERFLOW ROOF DRAIN

WITH CAST GRATING (NO

PLASTIC ALLOWED)

MEMBRANE ROOFING SYSTEM

FULLY ADHERED TO 1/2"

COVER BOARD WITH ISO

INSULATION FASTENED TO

METAL DECK SEE ROOF PLAN

FOR ADDITIONAL NOTES

METAL DECK - SEE

STRUCTURAL DRAWINGS

STEEL ANGLES - SEE

STRUCTURAL DRAWINGS

INSTALL INSULATION

UNDER DRAINS

DRAIN PIPE WITH INSULATION -

SEE PLUMBING DRAWINGS

DRAIN SUMP PAN

SEALANT - COLOR TO

MATCH COPING COLOR

METAL COPING AND

CONTINUOUS CLEAT

CONCEALED

SPLICE CLEAT

METAL COPING AND

CONTINUOUS CLEAT

CONCEALED

SPLICE CLEAT

SEALANT - COLOR TO

MATCH COPING COLOR

ELEVATION

PLAN VIEW

TEMPERATURE APPROPRIATE

ELASTOMERIC SEALANT

DRAWBAND OR WELD UMBRELLA

TO STACK

UMBRELLA

STORM COLLAR

METAL DECK SEE STRUCTURAL

STACK PIPE SEE MECHANICAL

MIN.

4"

MEMBRANE ROOFING SYSTEM

FULLY ADHERED TO 1/2" COVER

BOARD WITH ISO INSULATION

FASTENED TO METAL DECK SEE

ROOF PLAN FOR ADDITIONAL NOTES

1" AIR GAP TO

PIPE (TYP.)

1'

- 6

" M

IN

12" O.C. SPACING (STAGGERED)

FIRST 8' - 0" TYPICAL

" O

.C . S

PA

CI

NG

(S

TA

GG

ER

ED

FI

RS

T 8'

0"

T

YP

IC

AL

6"

1' - 0"

1' - 0"

2' - 0"

TYPICAL FASTENING SPACING

2'-0" O.C. AFTER 8'-0" CORNERS

NOTE:

TYPICAL STARTING NAILING

SPACING AT CORNERS AND

CONTINUED NAILING PATTERN

ALONG WALL

1'

- 0

6"

2'

- 0

1'

- 0

TY

PI

CA

L F

AS

TE

NI

NG

S

PA

CI

NG

2'- 0"

O .C

. A

FT

ER

8'

-0 " C

OR

NE

RS

MI

NI

MU

M

SEALANT (TYPICAL)

ROOF LAP SEALANT

CONT. (TYPICAL)

E.P.D.M. RUBBER BOOT W/

STAINLESS STEEL

FASTENER

ROOF LAP SEALANT

CONT. (TYPICAL)

x;1 '-0

VENT PIPE - SEE

PLUMBING OR

MECHANICAL

DRAWINGS.

8" M

IN

MEMBRANE ROOFING

SYSTEM FULLY ADHERED

TO COVER BOARD WITH

RIGID INSULATION

FASTENED TO METAL DECK

SEE ROOF PLAN FOR

ADDITIONAL NOTES

1" INSULATION OVER

EQUIPMENT RAILS. TYP.

(4) SIDES BY ROOFING

CONTRACTOR

EQUIPMENT RAIL

FLASHING ON

MEMBRANE UP & OVER

EQUIPMENT RAIL

EQUIPMENT HOUSING

SEE MECHANICAL

TAPERED INSULATION

AS REQUIRED

SE

E

ME

CH

AN

IC

AL

EQUIPMENT RAIL BY MECHANICAL

PLAN VIEW

ELEVATION

3/4" DIA. RUNGS

AT 12" O.C.

2 1/2" x 3/8" RAILS W/ TOP

END ROUNDED

2 1/2" x 3/8" BENT PLATES AT

TOP, BOTTOM 7'-0" O.C. MAX. W/

HY-270 1/2" DIA. ANCHORS

2' - 0"

3'

- 6

1'

- 0

1' - 6"

7"

TOP RUNG

ELEVATION

CAGE

REQ.LADDER LOCATION LANDING

ELEVATION

LADDER

MATERIAL

LADDER SCHEDULE

NOSTEELEL. 111'-6" V.I.F.ROOF LADDER A EL. 119'-4" V.I.F.

NOSTEELEL. 113'-6" V.I.F.ROOF LADDER B EL. 127'-0" V.I.F.

NOTE:

ALL STEEL USED SHALL

BE GALVANIZED

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

8:

:3

PM

A0.02

5-6249

OVERALL ROOF PLAN

RAM

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

AREA A AREA B

AREA C

AREA D

1/16" = 1'-0"

OVERALL ROOF PLAN

A0.02 1 1/2" = 1'-0"

7 TYPICAL ROOF CURB DETAIL

A0.02 1 1/2" = 1'-0"

1 SINGLE ROOF DRAIN DETAIL

A0.02 1 1/2" = 1'-0"

2 ROOF DRAIN OVERFLOW DETAIL

A0.02 3" = 1'-0"

5 METAL COPING SPLICE DETAIL

A0.02 1 1/2" = 1'-0"

4 STACK FLASHING DETAIL

A0.02 3/4" = 1'-0"

6 WOOD NAILER SECUREMENT CRITERIA

A0.02 1" = 1'-0"

3 TYPICAL ROOF VENT DETAIL

08.28.2025 BIDS &

CONSTRUCTION

A0.02 1 1/2" = 1'-0"

8 EQUIPMENT RAIL DETAIL

A0.02 1/2" = 1'-0"

9 TYPICAL LADDER DETAIL

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=83ac934f-d1fc-4663-86f4-b3d298be06da

SC

BF

BF

BF

BF

BF

R.

DW

REF.

DEMOLITION LEGEND

EXISTING WALL TO BE DEMOLISHED

PORTION OF EXISTING WALL TO BE DEMOLISHED

EXISTING OBJECT TO BE DEMOLISHED

EXISTING WALLS TO REMAIN

EXISTING OBJECTS TO REMAIN

XX DEMOLITION TAG: SEE DEMOLITION NOTES

AREA OF FLOOR CUTTING

ROOM NAME

CEILING FINISH

FLOOR FINISH

EXISTING ROOM FINISH INFORMATION:

ROOM NAME, FLOORING TYPE, CEILING TYPE

AREA OF CEILING REMOVAL AND REINSTALL

1005 1005 1005 1005

06 06

100507

07 07 07 07

12 12

04 04 06 06

04 04

13 13

13 CP

T

TO

B

E

RE

PL

AC

ED

TI

LE

T O

RE

MA

IN

20 20

20 20

20 20 20

04 06

04 04 04 04

06 04 04 06

04 04 04

040406040404

18 18 18

04 06

06 06

01 01

01 01

20 20 20 20

09 09

0909 09 09

09 09

09 09

1'

- 5

3'

- 2

4' - 9" 2' - 6" 3' - 2" 2' - 6" 5' - 1" 3' - 5" 2' - 6" 4' - 6" 2' - 6" 5' - 1"

SEE ELEVATIONS FOR

OPENING HEAD AND

SILL HEIGHT TYP.

3'

- 5

1/ 2"

2'

- 6

4'

- 6

2'

- 6

5'

- 1

SEE ELEVATIONS

FOR OPENING

HEAD AND SILL

HEIGHT TYP.

SEE ELEVATIONS

FOR OPENING

HEAD AND SILL

HEIGHT TYP.

REMOVE FLOOR SLAB AS

NEEDED FOR PLUMBING

WORK. PATCH AND

REPLACE TILE

REMOVE FLOOR

SLAB AS NEEDED

FOR ELECTRICAL

WORK

CLASSROOM

ACT

TOILET

TILE

TIME AWAY

ACT

SMALL GROUP

ACT

CLASSROOM

CPT

ACT

CLASSROOM

CPT

ACT

MECHANICAL

TOILET

TILE

ACT

TOILET

TILE

ACT

VESTIBULE

TILE

CORRIDOR

CPT

VESTIBULE

TILE

ELEC.

COMPUTER ROOM

CPT

ACT

CUSTODIAL

STORAGE

ACT

RESOURCE

CPT

ACT

CLASSROOM

CPT

ACT

CLASSROOM

CPT

ACT

TOILET

TILE

ACT

TOILET

TILE

ACT SP. ED. CLASSROOM

CPT

ACT

MUSIC CLASSROOM

CPT

ACT

TOILET

TILE

ACT

TOILET

TILE

ACT

MENS TOILET

TILE

ACT

WOMENS TOILET

TILE

ACT

AUDIO / VISUAL

CPT

ACT

MEDIA CENTER

CPT

ACT

VESTIBULE

CPT

ACT

CORRIDOR

ACT

STAFF LAB

OFFICE

WORK ROOM

TOILET

HEALTH

OFFICE

CONFERENCE

RECEPTION

VESTIBULE

COAT CLOSET

LOBBY

CORRIDOR

CPT

ACT

DEMOLITION NOTES

01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT

UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.

02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.

03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR

CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.

EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING

ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.

04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S

REQUEST.

05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &

WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.

06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)

07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE

WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.

08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR

REUSE BY OWNER.

09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND

BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.

16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.

11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.

PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.

12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT

SURFACES TO RECEIVE NEW FINISHES.

13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.

RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.

10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH

MATERIAL & PATCH TO MATCH EXISTING.

14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.

15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH

SCHEDULE FOR NEW FLOORING.

DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.

NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.

(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)

ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW

MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.

DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING

ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.

REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.

ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING

MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.

ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO

DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.

ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE

EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE

COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE

NEW LINTELS W/ MASONRY CONTRACTOR.

PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/

CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,

ROOF & FLOOR OPENINGS TO BE PATCHED.

ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.

17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.

18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.

19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)

20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).

WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT

SCHEDULES FOR NEW DOOR HARDWARE.

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

5:

:3

PM

A1.1A

5-6249

UNIT 'A' FIRST FLOOR

DEMOLITION PLAN

RAM

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

UNIT A UNIT B

UNIT C

1/8" = 1'-0"

UNIT 'A' FIRST FLOOR DEMOLITION PLAN

08.28.2025 BIDS &

CONSTRUCTION

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e

IC

IC

SC

ACS

BF

BF

BF

R.

SC

DEMOLITION NOTES

01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT

UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.

02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.

03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR

CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.

EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING

ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.

04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S

REQUEST.

05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &

WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.

06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)

07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE

WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.

08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR

REUSE BY OWNER.

09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND

BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.

16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.

11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.

PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.

12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT

SURFACES TO RECEIVE NEW FINISHES.

13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.

RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.

10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH

MATERIAL & PATCH TO MATCH EXISTING.

14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.

15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH

SCHEDULE FOR NEW FLOORING.

DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.

NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.

(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)

ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW

MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.

DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING

ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.

REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.

ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING

MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.

ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO

DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.

ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE

EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE

COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE

NEW LINTELS W/ MASONRY CONTRACTOR.

PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/

CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,

ROOF & FLOOR OPENINGS TO BE PATCHED.

ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.

17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.

18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.

19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)

20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).

WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT

SCHEDULES FOR NEW DOOR HARDWARE.

DEMOLITION LEGEND

EXISTING WALL TO BE DEMOLISHED

PORTION OF EXISTING WALL TO BE DEMOLISHED

EXISTING OBJECT TO BE DEMOLISHED

EXISTING WALLS TO REMAIN

EXISTING OBJECTS TO REMAIN

XX DEMOLITION TAG: SEE DEMOLITION NOTES

AREA OF FLOOR CUTTING

ROOM NAME

CEILING FINISH

FLOOR FINISH

EXISTING ROOM FINISH INFORMATION:

ROOM NAME, FLOORING TYPE, CEILING TYPE

AREA OF CEILING REMOVAL AND REINSTALL

07 07 07

07 07

10 10

12 12

10 10

05 10

12 04

05 10

CA

RP

ET

T

O

BE

R

EP

LA

CE

D

TI

LE

T O

BE

R

EP

LA

CE

D

16 16

20 20

20 20

20 20

06 04

TI

LE

T O

BE

R

EP

LA

CE

D

W

OO

D

FL

OO

R

TO

R

EM

AI

N

1' - 3 1/4"

5' - 0"

REMOVE AND REINSTALL

CEILING AS REQUIRED

FOR ELECTRICAL AND

STRUCTURAL WORK

REMOVE AND

REPLACE ANY

MB OR TB IN

ROOM

09 09

DEMO WALL AS

NEEDED FOR NEW

LOUVER - SEE

MECHANICAL FOR

SIZE AND TYPE

REMOVE FLOOR

SLAB AS NEEDED

FOR PLUMBING

WORK. PATCH AND

REPLACE LVT

05 05

SEE ELEVATIONS FOR

OPENING HEAD AND

SILL HEIGHT TYP.

5 1/2" 3' - 2" 2' - 10 1/2"

SEE ELEVATIONS FOR

OPENING HEAD AND

SILL HEIGHT TYP.

5" 3' - 2" 2' - 11"

3' - 5" 2' - 6" 7"

2'

- 1

1" 3'

- 2

CLASSROOM

ACT

STORAGE

ACT

STORAGE

ACT

TOILET

TILE

KILN

ACT

KINDERGARTEN

CPT

STOR

CPT

OFFICE

CPT

TOILET

TILE

STAFF LOUNGE

CPT

KINDERGARTEN

CPT

STORAGE

CPT

KITCHEN

TILE

TOILET

TILE

VESTIBULE

CPT

ACT

CORRIDOR

CPT, TILE

WOMENS TOILET

TILE

MENS TOILET

TILE

READING

CPT

OFFICE

CPT

MULTI-PURPOSE ROOM

VCT

STAGE

STORAGE

ACT

JANITOR

ACT

FOOD SERVICE

ACT

FOOD STORAGE

ACT

MECHANICAL

LOBBY

TILE

VESTIBULE

TILE

VESTIBULE

TILE

MENS TOILET

TILE

ACT

WOMENS TOILET

TILE

ACT

LAUNDRY

TILE

ACT

SHOWER

TILE

ACT

GYM OFFICE

VCT

ACT

STORAGE

HALL

TILE

ACT

STORAGE STORAGE

GYMNASIUM

16 16

01 01 01 01 01 01 01

REMOVE EXISTING WINDOW

OPENING INFILL. PREP FOR

NEW WINDOOWS TYP.

MULTI-PURPOSE ROOM

VCT

STAGE

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

5:

:4

PM

A1.1B

5-6249

UNIT 'B' FIRST FLOOR

DEMOLITION PLAN

RAM

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

1/8" = 1'-0"

UNIT 'B' FIRST FLOOR DEMOLITION PLAN

UNIT A UNIT B

UNIT C

1/8" = 1'-0"

MULTI-PURPOSE CLERESTORY DEMOLITION PLAN

REMOVE EXISTING METAL PANEL.

BLOCK WALL AND ANY UNCOVERED

BRICK AND INSULATION TO REMAIN IN

PLACE

REMOVE EXISTING

METAL PANEL.

BLOCK WALL AND

ANY UNCOVERED

BRICK AND

INSULATION TO

REMAIN IN PLACE

REMOVE EXISTING

METAL PANEL.

BLOCK WALL AND

ANY UNCOVERED

BRICK AND

INSULATION TO

REMAIN IN PLACE

08.28.2025 BIDS &

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e

CR

CR

CR

CR

CR

SC

SC

ACS

ACS

BF

BF

BF

BFBF

BF BF

DEMOLITION NOTES

01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT

UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.

02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.

03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR

CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.

EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING

ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.

04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S

REQUEST.

05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &

WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.

06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)

07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE

WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.

08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR

REUSE BY OWNER.

09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND

BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.

16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.

11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.

PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.

12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT

SURFACES TO RECEIVE NEW FINISHES.

13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.

RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.

10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH

MATERIAL & PATCH TO MATCH EXISTING.

14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.

15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH

SCHEDULE FOR NEW FLOORING.

DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.

NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.

(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)

ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW

MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.

DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING

ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.

REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.

ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING

MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.

ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO

DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.

ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE

EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE

COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE

NEW LINTELS W/ MASONRY CONTRACTOR.

PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/

CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,

ROOF & FLOOR OPENINGS TO BE PATCHED.

ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.

17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.

18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.

19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)

20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).

WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT

SCHEDULES FOR NEW DOOR HARDWARE.

DEMOLITION LEGEND

EXISTING WALL TO BE DEMOLISHED

PORTION OF EXISTING WALL TO BE DEMOLISHED

EXISTING OBJECT TO BE DEMOLISHED

EXISTING WALLS TO REMAIN

EXISTING OBJECTS TO REMAIN

XX DEMOLITION TAG: SEE DEMOLITION NOTES

AREA OF FLOOR CUTTING

ROOM NAME

CEILING FINISH

FLOOR FINISH

EXISTING ROOM FINISH INFORMATION:

ROOM NAME, FLOORING TYPE, CEILING TYPE

AREA OF CEILING REMOVAL AND REINSTALL

05 05

05 05

05 05

05 05

05 05

07 07

07 07

070707070707

1010 10 10 10 10

05 05 05 05 05 05

050505

13 13

13 13

13 13 1313

13 13 13

13 13

13 13

13 13

04 04 04 04 04 04

04 04

06 04

20 20

20 20

20 20

20 20

20 20

20 20

202020

20 20 20

20 20

04 04 04

040404040404

09 09

09 09

09 0909090909

04 04

04 04

04 04

04 0404 04 0404

01 01

010101010101

ALT. A-1 ALT. A-1

1919 ALT. A-1 ALT. A-1

ALT. A-1

19 ALT. A-119 ALT. A-119 ALT. A-1

20 20

20 20

20 20

20 20

09 09

090909090909

05 05 05

1'

- 7

3'

- 2

SEE ELEVATIONS FOR

OPENING HEAD AND

SILL HEIGHT TYP.

1'

- 7

3'

- 2

1'

- 7

3'

- 2

1'

- 7

3'

- 2

1'

- 7

3'

- 2

7" 1'

- 7

3'

- 2

3'

- 2

1'

- 7

1'

- 7

3'

- 2

SEE ELEVATIONS

FOR OPENING

HEAD AND SILL

HEIGHT TYP.

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

TOILET

TILE

TOILET

TILE

TOILET

TILE

TOILET

TILE

SMALL GROUP

ACT

SMALL GROUP

ACT

TOILET

TILE

TOILET

TILE

SMALL GROUP

ACT

SMALL GROUP

ACT

TOILET

TILE

TOILET

TILE

CORRIDOR

ACT

COMPUTER LAB

AIDES ROOM

SPECIAL ED. ROOM

WORK ROOM

ACT

ELEC.

VESTIBULE

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CLASSROOM

ACT

CUSTODIAL

CUSTODIAN OFFICE

ACT

VESTIBULE

STORAGE

CLASSROOM

ACT

CLASSROOM

ACT

SMALL GROUP

ACT

TOILET

TILE

TOILET

TILE

TOILET

TILE

TOILET

TILE

SMALL GROUP

ACT

TOILET

TILE

SMALL GROUP

ACT

TOILET

TILE

TOILET

TILE

SMALL GROUP

ACT

TOILET

TILE

STAFF WORK ROOM

CT

ACT

STAFF PLANNING

ACT

GIRLS TOILET

TILE

ACT

STAFF

TILE

ACT

STAFF

TILE

ACT

BOYS TOILET

TILE

ACT

CUSTODIAL

CORRIDOR

ACT

CORRIDOR

ACT

VESTIBULE

STORAGE

CLASSROOM

CLASSROOM

MECH

MECH

TOILET

TOILET

TIME AWAY

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

5:

:5

PM

A1.1C

5-6249

UNIT 'C' FIRST FLOOR

DEMOLITION PLAN

RAM

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

UNIT A UNIT B

UNIT C

1/8" = 1'-0"

UNIT 'C' FIRST FLOOR DEMOLITION PLAN

08.28.2025 BIDS &

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e

ATSMTS ATS

T

T

BFBF

BF

R.

DW

REF.

BF

BF

BF BF BF BF

BF

BF

BFBF

BF

GENERAL FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

A.

B.

C.

DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.

REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION.

INTERIOR STUD WALLS ARE TO USE 3 5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED.

TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED

OTHERWISE.

SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFR.)

EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.

REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING, ETC.

FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.

PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT, ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL

CONTRACTOR / SITE SUPERVISOR.

COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMMODATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS, ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS

APPROVED BY ARCHITECT.

ALL GUARDRAILS AND HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE 2015 M.B.C., ANSI ICC A117.1-2017 & AMERICANS WITH DISABILITIES ACT GUIDELINES. THE MOST STRINGENT SHALL

PREVAIL.

PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER DETAILS. SEE G0.01 FOR REQUIREMENTS.

FOR ALL CABINETRY, SEE INTERIOR ELEVATIONS FOR LAYOUTS. FIELD VERIFY CLEAR WIDTHS PRIOR TO FABRICATION.

ALL EXTERIOR BLOCK CORNERS ARE TO BE BULLNOSE BLOCK EXCEPT CONCRETE BLOCK COLUMNS, PIERS AND WALLS TO

RECEIVE TILE - UNLESS NOTED OTHERWISE.

CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW

CONSTRUCTION. TYPICAL THROUGHOUT.

SEAL ALL PENETRATIONS IN FIRE RATED FLOORS AND WALLS WITH APPROVED FIRESTOPPING.

WHERE SPECIALTY BLOCK IS REQUIRED AT THE SAME HEIGHT ON BOTH SIDES OF A WALL USE (2) SPECIALTY BLOCKS BACK TO BACK TO MAINTAIN THE FINISHED WALL APPEARANCE BOTH SIDES OF THE WALL. COORDINATE WITH STRUCTURAL FOR

LINTELS CONDITIONS PER SPECIFICATIONS.

WALLS TO BE PATCHED WITH LIKE MATERIALS WHERE EXISTING WALLS HAVE BEEN COMPROMISED FROM DEMOLITION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL AND REINSTALLATION OF CASEWORK AND WALL MOUNTED EQUIPMENT IN ORDER TO ACHIEVE SAID PATCH. IN AREAS WHERE BLOCK OR BRICK HAVE BEEN USED, NEW MASONRY TO BE TOOTHED IN AND MATCH EXISTING. AREAS AND FINISHES IN QUESTION SHALL BE COORDINATED WITH

ARCHITECT.

SEE STRUCTURAL FRAMING PLANS FOR ADDITIONAL WALL REINFORCING REQUIREMENTS. MINIMUM REINFORCING (FOR ALL

WALLS NOT OTHERWISE NOTED ON STRUCTURAL PLANS):

ALL BEARING WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.

ALL EXTERIOR WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.

ALL INTERIOR NON-BEARING WALLS OVER 16'-0" HIGH SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.

WALL LEGEND

5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

CMU WALL SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN

(8" TYPICAL U.N.O.)

5/8" GYP. BOARD BOTH SIDES 6" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN

-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR

GYPSUM WALL BOARD UNLESS NOTED OTHERWISE

BRICK AND CMU WALL W/ 2" SPRAY APPLIED

INSULATION SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN. SEE WALL SECTIONS FOR ADDITIONAL

DETAILS, BANDING, ETC.

(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)

CONCRETE WALL SEE STRUCTURAL

PLANS FOR REQUIRED REINFORCING.

4 7 /8"

7 1 /4"

SE

E

PL

AN

SE

E

PL

AN

SE

E

PL

AN

CLASSROOM

A138

T.

A139

CLOSET

A140

SMALL GROUP

A141

CLASSROOM

A116

CLASSROOM

A119

MECHANICAL

A121

T.

A117

T.

A118

VESTIBULE

A115

CORRIDOR

A122

VESTIBULE

A123

ELEC.

A120

COMPUTER ROOM

A114

CUSTODIAL

A124 STORAGE

A125

RESOURCE

A126

CLASSROOM

A127

CLASSROOM

A130

T.

A128

T.

A129

CLASSROOM

A131

MUSIC CLASSROOM

A134

T.

A132

T.

A133

BOYS T.

A135

GIRLS T.

A136

AUDIO / VISUAL

A112

MEDIA CENTER

A113

VESTIBULE

A137

CORRIDOR

A142

STAFF LAB

A111

OFFICE

A105

WORK ROOM

A107

TOILET

A108

HEALTH

A109

OFFICE

A104

CONFERENCE

A103

RECEPTION

A102

VESTIBULE

A100

COAT CLOSET

A106

CORRIDOR

A101

CORRIDOR

A110

NEW MILLWORK

CIRCULATION

DESK

A2.80

A116A

A119A

A124A A125A A127A A130A

A114A A113A A112A

A112B

A131A A134A

A138A

A101A

W03

W02

W04 W01 W02 W01 W02

A8.01

W01

W07

BL01

A8.01

A4.01

A8.01 23

A8.01 45

A8.01 6

A8.01

2 SIM

A8.01

4 SIM

A8.01

2 SIM

A8.01

A8.01

A8.01

A8.01

A8.01

A8.0112

" W x

" D 8 L

OC

KE

RS

" W x

" D

LO

CK

ER

S

15" W x 12" D

13 LOCKERS

15" W x 12" D

9 LOCKERS

15" W x 12" D

6 LOCKERS

15" W x 12" D

26 LOCKERS

" W x

" D

LO

CK

ER

S

" W x

" D 8 L

OC

KE

RS

" W x

" D

4 L

OC

KE

RS

" W x

" D 4 L

OC

KE

RS

" W x

" D 4 L

OC

KE

RS

" W x

" D

7 L

OC

KE

RS

A2.80

" W x

" D

LO

CK

ER

S

4' - 9" 2' - 6"

3' - 2"

2' - 6" 5' - 1" 3' - 5" 2' - 6" 4' - 6" 2' - 6" 5' - 1"

3'

- 5

1/ 4"

2'

- 6

4'

- 5 3/

4" 2'

- 6

5'

- 1

A117A

A118A

A128A A129A A132A A133A

A140A

A141A

A139A B139A

A4.01

A4.01 4

A120A A121A

INFILL OPENING BELOW

WINDOW, WHERE THE

LOUVER IS REMOVED,

WITH BRICK & BLOCK PER

DETAIL - SEE MECHANICAL

INFILL OPENING

BELOW WINDOW,

WHERE THE

LOUVER IS

REMOVED, WITH

BRICK & BLOCK

PER DETAIL - SEE

MECHANICAL

INFILL OPENING BELOW WINDOW,

WHERE THE LOUVER IS REMOVED,

WITH BRICK & BLOCK PER DETAIL -

SEE MECHANICAL

INFILL OPENING BELOW

WINDOW, WHERE THE

LOUVER IS REMOVED,

WITH BRICK & BLOCK

PER DETAIL - SEE

MECHANICAL

INFILL OPENING BELOW WINDOW,

WHERE THE LOUVER IS REMOVED,

WITH BRICK & BLOCK PER DETAIL -

SEE MECHANICAL

INFILL OPENING

BELOW WINDOW,

WHERE THE

LOUVER IS

REMOVED, WITH

BRICK & BLOCK

PER DETAIL - SEE

MECHANICAL

A113B

A141B

A7.03

TYP

A7.03

TYP

CMU

4"

CMU

4"

4"

8 SIM

A2.80 8

12'W MB / 4'W TB X 4'H

12'W MB / 4'W TB X 4'H

12'W MB / 4'W TB X 4'H

12'W MB / 4'W TB X 4'H

8'W X 4'H MB 8'W X 4'H MB

8'W X

4' H

TB

8'W

X 4'

H

TB

8'W X

4' H

TB

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

'W

M B

/ 4 'W

T B

X 4'H

12'W MB / 4'W TB X 4'H

6'W X

4' H

TB

AS A STANDARD, WHERE 30" DEEP

C-TOPS ARE SHOWN TO

ACCOMODATE 30" DEEP POSTER

UNITS, INSTALL ALL CABS FLUSH

WITH FRONT FACE OF POSTER CAB;

TYP. ENTIRE BUILDINGS, ALL AREAS

OF NEW CASEWORK

1' - 4"

CM

U

TY

P.

4"

4"

6'W X

4' H

TB

2'

- 0

4"

PROJECT NO.

DRAWN

REVIEWED

NO PART OF THIS DRAWING MAY BE

USED OR REPRODUCED IN ANY FORM

OR BY ANY MEANS, OR STORED IN A

DATA BASE OR RETRIEVAL SYSTEM,

WITHOUT PRIOR WRITTEN

PERMISSION OF

ALL RIGHTS RESERVED

c

KEYPLAN

ISSUANCES

GMB COPYRIGHT

Au to de sk

D oc s:

//5

-6

W es t O tta w a W au ka zo o

El em en ta ry Im pr ov em en ts /5

-6

9A

5.

rv t

8/

/2

5:

:2

PM

A2.1A

5-6249

UNIT 'A' FIRST FLOOR PLAN

ERE

AMS

W A

U K

A Z

O O

E

LE

M E

N T

A R

Y S

C H

O O

L

IM

P R

O V

E M

E N

T S

W E

S T

O

TT

A W

A P

U B

LI

C

S C

H O

O

LS

H O

LL

A

N D

M

IC

H

IG

A

N

UNIT A UNIT B

UNIT C 1/8" = 1'-0"

UNIT 'A' FIRST FLOOR PLAN

08.28.2025 BIDS &

CONSTRUCTION

https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=75533ce3-c48d-4e4f-a7b6-d84736eccc67 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=5c692462-920b-4afd-9d64-d541af8a7cd3 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=5c692462-920b-4afd-9d64-d541af8a7cd3 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce

BF

BF

BF

BF

BF

BF

BF

BFBF

BF

BF

BF

BF

BF

R.BF

WALL LEGEND

5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

CMU WALL SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN

(8" TYPICAL U.N.O.)

5/8" GYP. BOARD BOTH SIDES 6" LIGHT GA.

METAL FRAMING AT 16" O.C. SOUND BATT

FULL HEIGHT OF WALL. WALLS TO BOTTOM

OF DECK UNLESS NOTED OTHERWISE

-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN

-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR

GYPSUM WALL BOARD UNLESS NOTED OTHERWISE

BRICK AND CMU WALL W/ 2" SPRAY APPLIED

INSULATION SEE FLOOR PLANS FOR REQUIRED

WALL REINFORCING. NOMINAL DIMENSIONS

GIVEN. SEE WALL SECTIONS FOR ADDITIONAL

DETAILS, BANDING, ETC.

(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)

CONCRETE WALL SEE STRUCTURAL

PLANS FOR REQUIRED REINFORCING.

4 7 /8"

7 1 /4"

SE

E

PL

AN

SE

E

PL

AN

SE

E

PL

AN

GENERAL FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

A.

B.

C.

DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.

REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION.

INTERIOR STUD WALLS ARE TO USE 3 5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED.

TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED

OTHERWISE.

SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFR.)

EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.

REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED

INCLUDING NECESSARY FRAMING, BLOCKING, ETC.

FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.

PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT, ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL

CONTRACTOR / SITE SUPERVISOR.

COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMMODATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS, ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS

AP…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .