Waukazoo Drawings.pdf
PDF 27 MB Posted
- Attached to
- ELEMENTARY IMPROVEMENTS
- Solicitation number
- RFP-WOP-250000003178-4
- Issued by
- Saginaw County, Michigan
About this file
This file contains architectural drawings for the Waukazoo Elementary School Improvements project located in Holland, Michigan for West Ottawa Public Schools, dated 2025. The drawings specifically show demolition and first floor plans for three building units (A, B, and C).
The architectural drawings include detailed floor plans with room layouts, demolition notes, wall legends, and general floor plan notes. Key details include comprehensive room numbering and designations such as classrooms, toilets, mechanical rooms, corridors, storage areas, and administrative spaces. The plans indicate proposed wall removals, window and door modifications, and overall spatial reorganization of the school's interior. The documents appear to be part of a significant renovation project covering multiple building units, with precise architectural specifications for demolition and reconstruction of interior spaces.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TT
T
T
T
T
T
T
T
BF
BF
BFBF
BF
BF
BF
BF
BF
R. DW REF.
BFBF
BF BF
BF
BF
BF
BF
BF BF BF BF
BF
BF
BFBF
BF BF
BFBF
BFBF
BFBF BF
BFBF
BFBFBF
BF
BF
BF
BF
BF
BF
BFBF
BF
BF
BF
BF
BF
R.BF
A4.01
CLASSROOM
C101
CLASSROOM
C105
CLASSROOM
C106
CLASSROOM
C110
CLASSROOM
A138
CLASSROOM
B142
CLASSROOM
C167
CLASSROOM
C163
CLASSROOM
C162
CLASSROOM
C158
T.
A139
CLOSET
A140
SMALL GROUP
A141
STORAGE
B140
STORAGE
B141
T.
B139
KILN
B138
T.
C102
T.
C166
T.
C104
T.
C164
SMALL GROUP
C103
SMALL GROUP
C165
T.
C107
T.
C161
SMALL GROUP
C108
SMALL GROUP
C160
T.
C109
T.
C159
CORRIDOR
C100
CLASSROOM
C113
AIDES ROOM
C114
SPECIAL ED. ROOM
C115
WORK ROOM
C111
ELEC.
C112
CLASSROOM
C127
CLASSROOM
C131
CLASSROOM
C132
CLASSROOM
C136
CLASSROOM
C137
CLASSROOM
C141
CUSTODIAL
C142
OFFICE
C143
VESTIBULE
C144
STORAGE
C145
CLASSROOM
C146
CLASSROOM
C150
SMALL GROUP
C148
T.
C147
T.
C149
T.
C138
T.
C140
SMALL GROUP
C139
T.
C135
SMALL GROUP
C134
T.
C133
T.
C130
SMALL GROUP
C129
T.
C128
WORK ROOM
C152
STAFF PLANNING
C153
GIRLS T.
C156
T.
C157
T.
C126
BOYS T.
C155
CUSTODIAL
C154
CORRIDOR
C126
CORRIDOR
C151
CLASSROOM
A116
CLASSROOM
A119
MECHANICAL
A121
T.
A117
T.
A118
VESTIBULE
A115
CORRIDOR
A122
VESTIBULE
A123
ELEC.
A120
COMPUTER ROOM
A114
CUSTODIAL
A124
STORAGE
A125
RESOURCE
A126
CLASSROOM
A127
CLASSROOM
A130
T.
A128
T.
A129 CLASSROOM
A131
MUSIC CLASSROOM
A134T.
A132 T.
A133
BOYS T.
A135
GIRLS T.
A136
AUDIO / VISUAL
A112
MEDIA CENTER
A113
VESTIBULE
A137
CLASSROOM
B102
STORAGE
B103
OFFICE
B104
T.
B105
CLASSROOM
B107
CLASSROOM
B132STORAGE
B136
KITCHEN
B133
T.
B134
VESTIBULE
B137
CORRIDOR
B100
GIRLS T.
B108
BOYS T.
B109
READING
B110
OFFICE
B111
MULTI-PURPOSE ROOM
B130
PLATFORM
B131
STORAGE
B126
CUSTODIAL
B127
FOOD SERVICE
B128 STORAGE
B129
MECHANICAL
B112
CORRIDOR
B114
VESTIBULE
B113
VESTIBULE
B115
BOYS T.
B118
GIRLS T.
B119
STORAGE
B120
GYM OFFICE
B122
STORAGE
B123
CORRIDOR
B116
STORAGE
B124
STORAGE
B125
GYMNASIUM
B117
CORRIDOR
A142
STAFF LAB
A111
OFFICE
A105
WORK ROOM
A107
TOILET
A108
HEALTH
A109
OFFICE
A104
CONFERENCE
A103
RECEPTION
A102
VESTIBULE
A100
CORRIDOR
A101
CORRIDOR
C118
VESTIBULE
C117
STORAGE
C119
CLASSROOM
C124
CLASSROOM
C120
MECH
C125
MECH
C121
T.
C123
T.
C122
TIME AWAY
C116
A4.01
A4.01
A4.01
A4.01 4
A4.02 2
A4.02
A4.02
A4.02
A4.024
A8.01
A8.0129
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
5:
:3
PM
A0.01
5-6249
OVERALL FIRST FLOOR PLAN
ERE
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
1/16" = 1'-0"
OVERALL FIRST FLOOR PLAN
UNIT A UNIT B
UNIT C
08.28.2025 BIDS &
CONSTRUCTION
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=f1ba59bd-6807-47cc-96b2-5348eea31b55 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497
CORE #1
CORE #2
CORE #3
CORE #4
CORE #5
CORE #6
CORE #7
CORE #8CORE #9 CORE #10
CORE #11
CORE #12
CORE #13
CORE #14
CORE #16
CORE #15
ROOF LADDER B
ROOF LADDER A
1" 7"
0" M
IN
3"
13' - 2"
TAPERED RIGID INSULATION (4' - 0" SECTIONS)
1/4" PER FOOT SLOPE UNLESS OTHERWISE
NOTED
DIRECTION OF ROOF SLOPE.
WITH TAPERED INSULATION
ROOF HATCH
STANDARD ROOF DRAIN
LEGEND
GENERAL NOTES
ROOF WALKWAY PAD
(SEE SPEC. FOR
MATERIAL)
TAPERED RIGID INSULATION (4' - 0" SECTIONS
@ 1/4" SLOPE PER FOOT AT CRICKETS)
CRICKETS SLOPE TO ROOF DRAINS.
DIRECTION OF STRUCTURAL
ROOF SLOPE. (SEE STRUCTURAL
PLANS FOR ROOF FRAMING
SLOPES)
ROOF DRAIN LABELRD-5-1
THICKNESS OF TAPERED INSULATION AT
PERIMETER OR DRAIN (NOT INCLUDING
BASE INSULATION THICKNESS)
+ 7 1/4"
ROOF DRAIN NUMBER
ROOF AREA (SEE ROOF KEYPLAN)
RD OR ORD
CR#1 CORE SAMPLE LOCATIONS SEE
LEGEND FOR DESCRIPTION
CORE #1 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,
1/2" WOOD FIBER BOARD, TAPERED EPS INSULATION,
3/4" FESCO, ON EXISTING METAL DECK.
CORE SAMPLE DESCRIPTION
CORE #2
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ROOF DETAILS - LOCATED ON SHEET A7.01
ROOF DRAIN
ROOF OVERFLOW DRAIN
FASTENING ENHANCEMENT AT CORNER - SEE SPEC AND DETAIL
PLUMBING VENT
STACK FLASHING
METAL COPING SPLICE DETAIL
ROOF CURB DETAIL
RE-ROOFING EXISTING NAILERS / BLOCKING TO REMAIN:
CONTRACTOR TO FIELD VERIFY THE EXISTING NAILERS / BLOCKING
WILL COMPLY TO MEET THE WIND UP LIFT CRITERIA. REMOVE ALL
DAMAGED NAILERS / BLOCKING AND / OR INSTALL ADDITIONAL
FASTENER AS REQUIRED TO COMPLY.
REFER TO PLUMBING DRAWINGS FOR LOCATION AND NUMBER OF
PLUMBING VENTS THRU ROOF.
REFER TO MECHANICAL DRAWINGS TO COORDINATE ALL ROOF
PENETRATIONS & LOCATIONS.
PROVIDE 1/2" TAPERED CRICKETS AT ALL ROOF HATCHES AND
MECHANICAL ROOF PENETRATIONS UNLESS OTHERWISE NOTED.
TAPER SHALL PROVIDE DRAINAGE AROUND HATCH AND EQUIPMENT.
SEE SPECIFICATION FOR ROOFING SYSTEM TO BE USED AND ROOF
PLAN FOR LOCATIONS OF TAPERED INSULATION AND OR SLOPE
CHANGES OF ROOF.
CONTRACTOR RESPONSIBLE TO FIELD VERIFY ALL SQUARE
FOOTAGE VALUES NOTED ON PLANS
IN AREAS WHERE EXISTING ROOF DRAINS ARE BEING REPLACED
WITH NEW ROOF DRAIN TO BE INSTALLED IN THE EXACT LOCATION
OF EXISTING AND WILL BE CONNECTED TO EXISTING PIPING AS
REQUIRED.
SCUPPER LOCATIONS TO BE COORDINATED SO THAT THEY DO NOT
APPEAR OVER DOORS, WINDOWS OR MECHANICAL LOUVERS
STANDARD ROOF ABBREVIATIONS
RD = ROOF DRAIN
ORD = OVERFLOW ROOF DRAIN
EF = EXHAUST FAN
IV = INTAKE VENT
RTU = ROOF TOP UNIT
RV = RELIEF VENT
ST. SLOPE
SLOPE
DURALAST PVC ROOFING, EPDM MEMBRANE,
TAPERED EPS INSULATION, 3/4" FESCO, ON
EXISTING METAL DECK.
CORE #3 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,
3 1/2" POLYISOCYANURATE INSULATION, TAPERED EPS
INSULATION, 2" POLYISOCYANURATE INSULATION, ON
EXISTING METAL DECK.
CORE #4 DURALAST PVC ROOFING, EPDM ROOFING MEMBRANE,
3 1/2" POLYISOCYANURATE INSULATION, ON EXISTING
METAL DECK.
CORE #5 DURALAST PVC ROOFING, 3 1/2" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #6 DURALAST PVC ROOFING, 2" POLYISOCYANURATE
INSULATION, TAPERED EPS INSULATION, DURALAST
PVC ROOFING, 2" POLYISOCYANURATE, ON EXISTING
METAL DECK.
CORE #7 DURALAST PVC ROOFING, 2" POLYISOCYANURATE
INSULATION, TAPERED EPS INSULATION, 2"
POLYISOCYANURATE, ON EXISTING METAL DECK.
CORE #8 DURALAST PVC ROOFING, 2" POLYISOCYANURATE
INSULATION, TAPERED EPS INSULATION, 2"
POLYISOCYANURATE, ON EXISTING METAL DECK.
CORE #9 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING CONCRETE DECK.
CORE #10 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #11 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #12 DURALAST PVC ROOFING, 2"
POLYISOCYANURATE INSULATION, 1/2" WOOD
FIBER BOARD, 2" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #13 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #14 DURALAST PVC ROOFING, 6" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #15 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
CORE #16 DURALAST PVC ROOFING, 4" POLYISOCYANURATE
INSULATION, ON EXISTING METAL DECK.
AREAS WHERE PARAPET
NEEDS TO BE RAISED
STEEL ANGLE FRAME
AROUND PERIMETER EXTEND
TO ROOF STRUCTURE - SEE
STRUCTURAL DRAWINGS
MEMBRANE ROOFING SYSTEM
FULLY ADHERED TO COVER
BOARD WITH ISO INSULATION
FASTENED TO METAL DECK
SEE ROOF PLAN FOR
ADDITIONAL NOTES
EXTEND ROOF MEMBRANE
UP & OVER CURB
PRE-FABRICATED
INSULATED ROOF CURB
PROVIDE AT BALLASTED ROOF
AREAS ONLY - VAPOR BARRIER
TO RUN UP CURB & BE SEALED
TO INSIDE FACE OF CURB.
EQUIPMENT HOUSING OR
FLASHING - SEE
MECHANICAL DRAWINGS
TREATED 2x WOOD BLOCKING
AS REQUIRED AROUND CURB
OPENING PERIMETER
MI
N.8"
ROOF DRAIN WITH CAST
GRATING (NO PLASTIC
ALLOWED)
MEMBRANE ROOFING
SYSTEM FULLY ADHERED
TO 1/2" COVER BOARD WITH
ISO INSULATION FASTENED
TO METAL DECK SEE ROOF
PLAN FOR ADDITIONAL
NOTES
METAL DECK - SEE
STRUCTURAL DRAWINGS
STEEL ANGLES - SEE
STRUCTURAL DRAWINGS
INSTALL INSULATION
UNDER DRAINS
DRAIN PIPE WITH INSULATION -
SEE PLUMBING DRAWINGS
DRAIN SUMP PAN
INSTALL 4'-0" x 4'-0" 1/2"
PER FOOT SLOPE PREFAB
INSULATED DRAINSET AT
EACH ROOF DRAIN TO
PROVIDE POSITIVE SLOPE
TO DRAIN
OVERFLOW ROOF DRAIN
WITH CAST GRATING (NO
PLASTIC ALLOWED)
MEMBRANE ROOFING SYSTEM
FULLY ADHERED TO 1/2"
COVER BOARD WITH ISO
INSULATION FASTENED TO
METAL DECK SEE ROOF PLAN
FOR ADDITIONAL NOTES
METAL DECK - SEE
STRUCTURAL DRAWINGS
STEEL ANGLES - SEE
STRUCTURAL DRAWINGS
INSTALL INSULATION
UNDER DRAINS
DRAIN PIPE WITH INSULATION -
SEE PLUMBING DRAWINGS
DRAIN SUMP PAN
SEALANT - COLOR TO
MATCH COPING COLOR
METAL COPING AND
CONTINUOUS CLEAT
CONCEALED
SPLICE CLEAT
METAL COPING AND
CONTINUOUS CLEAT
CONCEALED
SPLICE CLEAT
SEALANT - COLOR TO
MATCH COPING COLOR
ELEVATION
PLAN VIEW
TEMPERATURE APPROPRIATE
ELASTOMERIC SEALANT
DRAWBAND OR WELD UMBRELLA
TO STACK
UMBRELLA
STORM COLLAR
METAL DECK SEE STRUCTURAL
STACK PIPE SEE MECHANICAL
MIN.
4"
MEMBRANE ROOFING SYSTEM
FULLY ADHERED TO 1/2" COVER
BOARD WITH ISO INSULATION
FASTENED TO METAL DECK SEE
ROOF PLAN FOR ADDITIONAL NOTES
1" AIR GAP TO
PIPE (TYP.)
1'
- 6
" M
IN
12" O.C. SPACING (STAGGERED)
FIRST 8' - 0" TYPICAL
" O
.C . S
PA
CI
NG
(S
TA
GG
ER
ED
FI
RS
T 8'
0"
T
YP
IC
AL
6"
1' - 0"
1' - 0"
2' - 0"
TYPICAL FASTENING SPACING
2'-0" O.C. AFTER 8'-0" CORNERS
NOTE:
TYPICAL STARTING NAILING
SPACING AT CORNERS AND
CONTINUED NAILING PATTERN
ALONG WALL
1'
- 0
6"
2'
- 0
1'
- 0
TY
PI
CA
L F
AS
TE
NI
NG
S
PA
CI
NG
2'- 0"
O .C
. A
FT
ER
8'
-0 " C
OR
NE
RS
MI
NI
MU
M
SEALANT (TYPICAL)
ROOF LAP SEALANT
CONT. (TYPICAL)
E.P.D.M. RUBBER BOOT W/
STAINLESS STEEL
FASTENER
ROOF LAP SEALANT
CONT. (TYPICAL)
x;1 '-0
VENT PIPE - SEE
PLUMBING OR
MECHANICAL
DRAWINGS.
8" M
IN
MEMBRANE ROOFING
SYSTEM FULLY ADHERED
TO COVER BOARD WITH
RIGID INSULATION
FASTENED TO METAL DECK
SEE ROOF PLAN FOR
ADDITIONAL NOTES
1" INSULATION OVER
EQUIPMENT RAILS. TYP.
(4) SIDES BY ROOFING
CONTRACTOR
EQUIPMENT RAIL
FLASHING ON
MEMBRANE UP & OVER
EQUIPMENT RAIL
EQUIPMENT HOUSING
SEE MECHANICAL
TAPERED INSULATION
AS REQUIRED
SE
E
ME
CH
AN
IC
AL
EQUIPMENT RAIL BY MECHANICAL
PLAN VIEW
ELEVATION
3/4" DIA. RUNGS
AT 12" O.C.
2 1/2" x 3/8" RAILS W/ TOP
END ROUNDED
2 1/2" x 3/8" BENT PLATES AT
TOP, BOTTOM 7'-0" O.C. MAX. W/
HY-270 1/2" DIA. ANCHORS
2' - 0"
3'
- 6
1'
- 0
1' - 6"
7"
TOP RUNG
ELEVATION
CAGE
REQ.LADDER LOCATION LANDING
ELEVATION
LADDER
MATERIAL
LADDER SCHEDULE
NOSTEELEL. 111'-6" V.I.F.ROOF LADDER A EL. 119'-4" V.I.F.
NOSTEELEL. 113'-6" V.I.F.ROOF LADDER B EL. 127'-0" V.I.F.
NOTE:
ALL STEEL USED SHALL
BE GALVANIZED
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
8:
:3
PM
A0.02
5-6249
OVERALL ROOF PLAN
RAM
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
AREA A AREA B
AREA C
AREA D
1/16" = 1'-0"
OVERALL ROOF PLAN
A0.02 1 1/2" = 1'-0"
7 TYPICAL ROOF CURB DETAIL
A0.02 1 1/2" = 1'-0"
1 SINGLE ROOF DRAIN DETAIL
A0.02 1 1/2" = 1'-0"
2 ROOF DRAIN OVERFLOW DETAIL
A0.02 3" = 1'-0"
5 METAL COPING SPLICE DETAIL
A0.02 1 1/2" = 1'-0"
4 STACK FLASHING DETAIL
A0.02 3/4" = 1'-0"
6 WOOD NAILER SECUREMENT CRITERIA
A0.02 1" = 1'-0"
3 TYPICAL ROOF VENT DETAIL
08.28.2025 BIDS &
CONSTRUCTION
A0.02 1 1/2" = 1'-0"
8 EQUIPMENT RAIL DETAIL
A0.02 1/2" = 1'-0"
9 TYPICAL LADDER DETAIL
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=83ac934f-d1fc-4663-86f4-b3d298be06da
SC
BF
BF
BF
BF
BF
R.
DW
REF.
DEMOLITION LEGEND
EXISTING WALL TO BE DEMOLISHED
PORTION OF EXISTING WALL TO BE DEMOLISHED
EXISTING OBJECT TO BE DEMOLISHED
EXISTING WALLS TO REMAIN
EXISTING OBJECTS TO REMAIN
XX DEMOLITION TAG: SEE DEMOLITION NOTES
AREA OF FLOOR CUTTING
ROOM NAME
CEILING FINISH
FLOOR FINISH
EXISTING ROOM FINISH INFORMATION:
ROOM NAME, FLOORING TYPE, CEILING TYPE
AREA OF CEILING REMOVAL AND REINSTALL
1005 1005 1005 1005
06 06
100507
07 07 07 07
12 12
04 04 06 06
04 04
13 13
13 CP
T
TO
B
E
RE
PL
AC
ED
TI
LE
T O
RE
MA
IN
20 20
20 20
20 20 20
04 06
04 04 04 04
06 04 04 06
04 04 04
040406040404
18 18 18
04 06
06 06
01 01
01 01
20 20 20 20
09 09
0909 09 09
09 09
09 09
1'
- 5
3'
- 2
4' - 9" 2' - 6" 3' - 2" 2' - 6" 5' - 1" 3' - 5" 2' - 6" 4' - 6" 2' - 6" 5' - 1"
SEE ELEVATIONS FOR
OPENING HEAD AND
SILL HEIGHT TYP.
3'
- 5
1/ 2"
2'
- 6
4'
- 6
2'
- 6
5'
- 1
SEE ELEVATIONS
FOR OPENING
HEAD AND SILL
HEIGHT TYP.
SEE ELEVATIONS
FOR OPENING
HEAD AND SILL
HEIGHT TYP.
REMOVE FLOOR SLAB AS
NEEDED FOR PLUMBING
WORK. PATCH AND
REPLACE TILE
REMOVE FLOOR
SLAB AS NEEDED
FOR ELECTRICAL
WORK
CLASSROOM
ACT
TOILET
TILE
TIME AWAY
ACT
SMALL GROUP
ACT
CLASSROOM
CPT
ACT
CLASSROOM
CPT
ACT
MECHANICAL
TOILET
TILE
ACT
TOILET
TILE
ACT
VESTIBULE
TILE
CORRIDOR
CPT
VESTIBULE
TILE
ELEC.
COMPUTER ROOM
CPT
ACT
CUSTODIAL
STORAGE
ACT
RESOURCE
CPT
ACT
CLASSROOM
CPT
ACT
CLASSROOM
CPT
ACT
TOILET
TILE
ACT
TOILET
TILE
ACT SP. ED. CLASSROOM
CPT
ACT
MUSIC CLASSROOM
CPT
ACT
TOILET
TILE
ACT
TOILET
TILE
ACT
MENS TOILET
TILE
ACT
WOMENS TOILET
TILE
ACT
AUDIO / VISUAL
CPT
ACT
MEDIA CENTER
CPT
ACT
VESTIBULE
CPT
ACT
CORRIDOR
ACT
STAFF LAB
OFFICE
WORK ROOM
TOILET
HEALTH
OFFICE
CONFERENCE
RECEPTION
VESTIBULE
COAT CLOSET
LOBBY
CORRIDOR
CPT
ACT
DEMOLITION NOTES
01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT
UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.
02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.
03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR
CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.
EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING
ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.
04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S
REQUEST.
05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &
WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.
06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)
07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE
WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.
08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR
REUSE BY OWNER.
09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND
BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.
16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.
11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.
PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.
12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT
SURFACES TO RECEIVE NEW FINISHES.
13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.
RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.
10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH
MATERIAL & PATCH TO MATCH EXISTING.
14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.
15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH
SCHEDULE FOR NEW FLOORING.
DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.
NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.
(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)
ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW
MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.
DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING
ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.
REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.
ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING
MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.
ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO
DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.
ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE
EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE
COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE
NEW LINTELS W/ MASONRY CONTRACTOR.
PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/
CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,
ROOF & FLOOR OPENINGS TO BE PATCHED.
ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.
17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.
18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.
19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)
20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).
WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT
SCHEDULES FOR NEW DOOR HARDWARE.
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
5:
:3
PM
A1.1A
5-6249
UNIT 'A' FIRST FLOOR
DEMOLITION PLAN
RAM
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
UNIT A UNIT B
UNIT C
1/8" = 1'-0"
UNIT 'A' FIRST FLOOR DEMOLITION PLAN
08.28.2025 BIDS &
CONSTRUCTION
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e
IC
IC
SC
ACS
BF
BF
BF
R.
SC
DEMOLITION NOTES
01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT
UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.
02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.
03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR
CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.
EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING
ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.
04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S
REQUEST.
05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &
WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.
06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)
07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE
WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.
08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR
REUSE BY OWNER.
09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND
BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.
16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.
11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.
PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.
12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT
SURFACES TO RECEIVE NEW FINISHES.
13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.
RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.
10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH
MATERIAL & PATCH TO MATCH EXISTING.
14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.
15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH
SCHEDULE FOR NEW FLOORING.
DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.
NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.
(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)
ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW
MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.
DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING
ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.
REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.
ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING
MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.
ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO
DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.
ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE
EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE
COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE
NEW LINTELS W/ MASONRY CONTRACTOR.
PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/
CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,
ROOF & FLOOR OPENINGS TO BE PATCHED.
ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.
17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.
18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.
19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)
20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).
WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT
SCHEDULES FOR NEW DOOR HARDWARE.
DEMOLITION LEGEND
EXISTING WALL TO BE DEMOLISHED
PORTION OF EXISTING WALL TO BE DEMOLISHED
EXISTING OBJECT TO BE DEMOLISHED
EXISTING WALLS TO REMAIN
EXISTING OBJECTS TO REMAIN
XX DEMOLITION TAG: SEE DEMOLITION NOTES
AREA OF FLOOR CUTTING
ROOM NAME
CEILING FINISH
FLOOR FINISH
EXISTING ROOM FINISH INFORMATION:
ROOM NAME, FLOORING TYPE, CEILING TYPE
AREA OF CEILING REMOVAL AND REINSTALL
07 07 07
07 07
10 10
12 12
10 10
05 10
12 04
05 10
CA
RP
ET
T
O
BE
R
EP
LA
CE
D
TI
LE
T O
BE
R
EP
LA
CE
D
16 16
20 20
20 20
20 20
06 04
TI
LE
T O
BE
R
EP
LA
CE
D
W
OO
D
FL
OO
R
TO
R
EM
AI
N
1' - 3 1/4"
5' - 0"
REMOVE AND REINSTALL
CEILING AS REQUIRED
FOR ELECTRICAL AND
STRUCTURAL WORK
REMOVE AND
REPLACE ANY
MB OR TB IN
ROOM
09 09
DEMO WALL AS
NEEDED FOR NEW
LOUVER - SEE
MECHANICAL FOR
SIZE AND TYPE
REMOVE FLOOR
SLAB AS NEEDED
FOR PLUMBING
WORK. PATCH AND
REPLACE LVT
05 05
SEE ELEVATIONS FOR
OPENING HEAD AND
SILL HEIGHT TYP.
5 1/2" 3' - 2" 2' - 10 1/2"
SEE ELEVATIONS FOR
OPENING HEAD AND
SILL HEIGHT TYP.
5" 3' - 2" 2' - 11"
3' - 5" 2' - 6" 7"
2'
- 1
1" 3'
- 2
CLASSROOM
ACT
STORAGE
ACT
STORAGE
ACT
TOILET
TILE
KILN
ACT
KINDERGARTEN
CPT
STOR
CPT
OFFICE
CPT
TOILET
TILE
STAFF LOUNGE
CPT
KINDERGARTEN
CPT
STORAGE
CPT
KITCHEN
TILE
TOILET
TILE
VESTIBULE
CPT
ACT
CORRIDOR
CPT, TILE
WOMENS TOILET
TILE
MENS TOILET
TILE
READING
CPT
OFFICE
CPT
MULTI-PURPOSE ROOM
VCT
STAGE
STORAGE
ACT
JANITOR
ACT
FOOD SERVICE
ACT
FOOD STORAGE
ACT
MECHANICAL
LOBBY
TILE
VESTIBULE
TILE
VESTIBULE
TILE
MENS TOILET
TILE
ACT
WOMENS TOILET
TILE
ACT
LAUNDRY
TILE
ACT
SHOWER
TILE
ACT
GYM OFFICE
VCT
ACT
STORAGE
HALL
TILE
ACT
STORAGE STORAGE
GYMNASIUM
16 16
01 01 01 01 01 01 01
REMOVE EXISTING WINDOW
OPENING INFILL. PREP FOR
NEW WINDOOWS TYP.
MULTI-PURPOSE ROOM
VCT
STAGE
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
5:
:4
PM
A1.1B
5-6249
UNIT 'B' FIRST FLOOR
DEMOLITION PLAN
RAM
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
1/8" = 1'-0"
UNIT 'B' FIRST FLOOR DEMOLITION PLAN
UNIT A UNIT B
UNIT C
1/8" = 1'-0"
MULTI-PURPOSE CLERESTORY DEMOLITION PLAN
REMOVE EXISTING METAL PANEL.
BLOCK WALL AND ANY UNCOVERED
BRICK AND INSULATION TO REMAIN IN
PLACE
REMOVE EXISTING
METAL PANEL.
BLOCK WALL AND
ANY UNCOVERED
BRICK AND
INSULATION TO
REMAIN IN PLACE
REMOVE EXISTING
METAL PANEL.
BLOCK WALL AND
ANY UNCOVERED
BRICK AND
INSULATION TO
REMAIN IN PLACE
08.28.2025 BIDS &
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e
CR
CR
CR
CR
CR
SC
SC
ACS
ACS
BF
BF
BF
BFBF
BF BF
DEMOLITION NOTES
01 REMOVE EXISTING WALL INCLUDING DOORS, WINDOWS, BORROWED LITES, AND ANY EQUIPMENT OR FURNISHINGS ATTACHED TO WALL OR PORTION OF EXISTING WALL AS SHOWN ON FLOOR PLAN (MIN. 4" BELOW FLOOR SLAB) AND AS REQUIRED FOR NEW CONSTRUCTION. FLOOR SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW FLOOR MATERIAL. WALL SURFACE TO BE PATCHED AS REQUIRED TO RECEIVE NEW WALL FINISH. SEE MECHANICAL & ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS. SUPPORT
UNBRACED SECTIONS OF WALL OR ROOF AS REQUIRED.
02 REMOVE EXISTING BORROWED LITE OR DOOR & DOOR FRAME. (DOOR LINTEL TO REMAIN UNLESS OTHERWISE NOTED ON PLAN - SEE STRUCTURAL FOR ADDITIONAL INFORMATION). WHERE DOOR FRAMES ARE TO REMAIN, PROTECT FRAMES FROM DAMAGE. SAND AND PREP FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR SCHEDULE FOR REQUIRED NEW DOORS AND FRAMES OR ONLY NEW DOORS.
03 SAW CUT AND REMOVE FLOOR OR PORTION OF EXISTING FLOOR SLAB AS SHOWN OR DIMENSIONED ON FLOOR PLAN. FLOOR CUTS SHOWN REPRESENT APPROXIMATE SIZE, LOCATION AND INTENT OF FLOOR
CUTTING, FLOOR CUTTING MAY VARY FROM SHOWN, COORDINATE WITH ARCHITECT/ENGINEER.
EXCAVATE, FILL & COMPACT SOIL AS REQUIRED FOR NEW SLAB- COORDINATE WITH MECHANICAL/ ELECTRICAL DEMOLITION NOTES FOR RELATED ITEMS & LOCATIONS. INSTALL NEW SLAB TO MATCH EXISTING
ELEVATION. SEE STRUCTURAL FOR ADDITIONAL INFORMATION REGARDING SLAB REMOVAL.
04 REMOVE EXISTING CASEWORK/MILLWORK, COUNTER TOPS & BACK SPLASH. SAVE ITEMS AT OWNER'S
REQUEST.
05 REMOVE EXISTING SUSPENDED/PLASTER CEILING - INCLUDING ALL FRAMING, TILES, TEES, HANGERS &
WIRES USED TO SUPPORT THAT CEILING. REPLACE PER REFL. CEILING PLANS.
06 SEE MECHANICAL DEMOLITION NOTES FOR REMOVAL OF EXIST. PLUMBING/MECHANICAL (i.e. LAVATORIES, SINKS, WATER CLOSETS, URINALS, FIN TUBE, MECH. DUCTWORK, UNIT VENTS, ETC.)
07 REMOVE EXISTING WINDOW, WINDOW WALL WITH ALUMINUM FRAMING WITH METAL PANELS BELOW WINDOW, FRAME, SILL & GLAZING INCLUDING ALL EXISTING WOOD BLOCKING AND FRAMING ABOVE
WINDOWS TO ROOF AND/OR MASONRY TIES AT BRICK PIERS AND SIDE WALLS.
08 REMOVE EXISTING EQUIPMENT OR FURNISHINGS SECURED TO FLOOR, WALL OR CEILING AND STORE FOR
REUSE BY OWNER.
09 REMOVE EXISTING CHALK, TACK OR WHITE BOARD. REMOVE ALL GLUE RESIDUE, ETC. FROM BLOCK BEHIND
BOARD AND PREPARE SURFACE FOR NEW FINISH MATERIALS WHERE REQUIRED.
16 REMOVE EXISTING BASKETBALL BACKBOARD AND ALL RELATED HANGERS, FASTENERS AND FRAMING TO STRUCTURE ABOVE. REMOVE HEIGHT ADJUSTMENT CABLES AND PULLEY SYSTEM IN ITS ENTIRETY.
11 REMOVE PORTION OF EXISTING ROOF & STRUCTURE (AS SHOWN ON DEMOLITION PLAN). PROVIDE TEMPORARY WEATHER PROTECTION AS NEEDED AROUND PERIMETER OF ROOF REMOVAL AS REQUIRED.
PROVIDE TEMPORARY SHORING & BRACING AS REQUIRED.
12 REMOVE EXISTING TOILET PARTITION, DISPENSERS AND/OR TOILET ACCESSORIES AND REPAIR ADJACENT
SURFACES TO RECEIVE NEW FINISHES.
13 REMOVE EXISTING LOCKERS AND LOCKER BASE. CUT SLOPED LOCKER TOP & BASE AS NECESSARY.
RE-USE/RELOCATE EXISTING END PANEL(S) AS REQUIRED. REVISE & PREPARE FOR NEW FINISHES.
10 REMOVE EXISTING FLOOR COVERING AND BASE, INCLUDING ALL GLUE RESIDUE, MUDBEDS, ETC. FROM FLOORS & WALLS AND PREPARE SURFACE FOR NEW FINISH MATERIALS, INCLUDING GRINDING, PATCHING AND/OR SELF-LEVELING COMPOUND AS REQUIRED. WALL & FLOOR SURFACE TO RECEIVE NEW FINISH
MATERIAL & PATCH TO MATCH EXISTING.
14 REMOVE EXISTING MEZZANINE INCLUDING ALL SUPPORT FRAMING, FLOOR DECK, HANGERS AND ALL ADDITIONAL RELATED MATERIALS. REPAIR WALL TO MATCH ADJACENT WALL MATERIALS AND FINISH.
15 REMOVE EXISTING TERRAZZO FLOORING, CONCRETE SLAB AND COVED BASE. REFER TO ROOM FINISH
SCHEDULE FOR NEW FLOORING.
DEMOLITION CONTRACTOR IS TO STOP WORK IMMEDIATELY IN AREA IF ASBESTOS IS ENCOUNTERED.
NOTIFY CONSTRUCTION MANAGER OF SUSPECTED AREA SO PROPER ABATEMENT CAN BE DONE.
(UNDER A SEPARATE ASBESTOS ABATEMENT CONTRACT AS NEGOTIATED BY OWNER.)
ALL MASONRY BLOCK AND BRICK WALLS TO BE REMOVED MUST BE TOOTHED TO RECEIVE NEW
MASONRY, UNLESS NOTED OTHERWISE ON DRAWINGS.
DEMOLITION CONTRACTOR IS TO PROVIDE TEMPORARY SHORING AND BRACING FOR EXISTING
ROOF/FLOOR STRUCTURE AS REQUIRED UNTIL PERMANENT WALLS & LINTELS ARE INSTALLED.
REFER TO STRUCTURAL & ARCHITECTURAL DRAWINGS FOR BEARING CONDITIONS.
ALL TRADES ARE TO COORDINATE ANY DEMOLITION, CAPPING OR ABANDONMENT OF EXISTING
MECHANICAL, ELECTRICAL, PLUMBING OR ARCHITECTURAL ITEMS.
ALL ITEMS TO BE SAVED AND/OR RELOCATED ARE TO BE STORED IN A PROPER MANNER SO NO
DAMAGE WILL OCCUR TO THESE ITEMS DURING THEIR STORAGE PERIOD.
ALL DEMOLITION WHICH DAMAGES ADJACENT SURFACES IS TO BE REPAIRED TO MATCH THE
EXISTING SURFACE DAMAGED (MATERIALS & FINISHES) AND ALL REPAIR WORK IS TO BE
COORDINATED WITH NEW CONSTRUCTION. FOR NEW OPENINGS IN EXISTING WALLS, COORDINATE
NEW LINTELS W/ MASONRY CONTRACTOR.
PATCH WALLS & ROOF TO MATCH EXISTING CONSTRUCTION BEHIND REMOVAL OF WALL LOUVERS, EXHAUST FANS, INTAKE HOODS & CABINET HEATERS. VERIFY SEQUENCE OF REMOVAL W/
CONSTRUCTION MANAGER. SEE MECHANICAL AND ELECTRICAL DEMOLITION SHEETS FOR WALL,
ROOF & FLOOR OPENINGS TO BE PATCHED.
ALL TRADES ARE TO COORDINATE THE REMOVAL OF EXISTING LOOSE EQUIPMENT WITH ARCHITECT AND/OR OWNER. ADDITIONAL EQUIPMENT FOUND THAT IS NOT NOTED ON DEMOLITION PLAN SHALL BE REMOVED AS PART OF GENERAL DEMOLITION AFTER VERIFICATION WITH ARCHITECT/OWNER.
17 REMOVE EXISTING PROJECTION SCREEN AND PROJECTOR. PROJECTOR TO BE RETURNED TO OWNER.
18 REMOVE EXISTING PA SYSTEM. SYSTEM TO BE RETURNED TO OWNER.
19 REMOVE EXISTING ACCORDION PARTITION AND REPLACE WITH SIMILAR. (ALT. A-1)
20 REMOVE EXISTING DOOR HARDWARE (DOORS AND FRAME TO REMAIN UNLESS OTHERWISE NOTED ON PLAN).
WHERE DOORS AND FRAMES ARE TO REMAIN, PROTECT DOORS AND FRAMES FROM DAMAGE. SAND AND PREP FRAME FOR NEW PAINT FINISH UNDER SECTION 09 90 00 SEE DOOR HARDWARE REPLACEMENT
SCHEDULES FOR NEW DOOR HARDWARE.
DEMOLITION LEGEND
EXISTING WALL TO BE DEMOLISHED
PORTION OF EXISTING WALL TO BE DEMOLISHED
EXISTING OBJECT TO BE DEMOLISHED
EXISTING WALLS TO REMAIN
EXISTING OBJECTS TO REMAIN
XX DEMOLITION TAG: SEE DEMOLITION NOTES
AREA OF FLOOR CUTTING
ROOM NAME
CEILING FINISH
FLOOR FINISH
EXISTING ROOM FINISH INFORMATION:
ROOM NAME, FLOORING TYPE, CEILING TYPE
AREA OF CEILING REMOVAL AND REINSTALL
05 05
05 05
05 05
05 05
05 05
07 07
07 07
070707070707
1010 10 10 10 10
05 05 05 05 05 05
050505
13 13
13 13
13 13 1313
13 13 13
13 13
13 13
13 13
04 04 04 04 04 04
04 04
06 04
20 20
20 20
20 20
20 20
20 20
20 20
202020
20 20 20
20 20
04 04 04
040404040404
09 09
09 09
09 0909090909
04 04
04 04
04 04
04 0404 04 0404
01 01
010101010101
ALT. A-1 ALT. A-1
1919 ALT. A-1 ALT. A-1
ALT. A-1
19 ALT. A-119 ALT. A-119 ALT. A-1
20 20
20 20
20 20
20 20
09 09
090909090909
05 05 05
1'
- 7
3'
- 2
SEE ELEVATIONS FOR
OPENING HEAD AND
SILL HEIGHT TYP.
1'
- 7
3'
- 2
1'
- 7
3'
- 2
1'
- 7
3'
- 2
1'
- 7
3'
- 2
7" 1'
- 7
3'
- 2
3'
- 2
1'
- 7
1'
- 7
3'
- 2
SEE ELEVATIONS
FOR OPENING
HEAD AND SILL
HEIGHT TYP.
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
TOILET
TILE
TOILET
TILE
TOILET
TILE
TOILET
TILE
SMALL GROUP
ACT
SMALL GROUP
ACT
TOILET
TILE
TOILET
TILE
SMALL GROUP
ACT
SMALL GROUP
ACT
TOILET
TILE
TOILET
TILE
CORRIDOR
ACT
COMPUTER LAB
AIDES ROOM
SPECIAL ED. ROOM
WORK ROOM
ACT
ELEC.
VESTIBULE
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CLASSROOM
ACT
CUSTODIAL
CUSTODIAN OFFICE
ACT
VESTIBULE
STORAGE
CLASSROOM
ACT
CLASSROOM
ACT
SMALL GROUP
ACT
TOILET
TILE
TOILET
TILE
TOILET
TILE
TOILET
TILE
SMALL GROUP
ACT
TOILET
TILE
SMALL GROUP
ACT
TOILET
TILE
TOILET
TILE
SMALL GROUP
ACT
TOILET
TILE
STAFF WORK ROOM
CT
ACT
STAFF PLANNING
ACT
GIRLS TOILET
TILE
ACT
STAFF
TILE
ACT
STAFF
TILE
ACT
BOYS TOILET
TILE
ACT
CUSTODIAL
CORRIDOR
ACT
CORRIDOR
ACT
VESTIBULE
STORAGE
CLASSROOM
CLASSROOM
MECH
MECH
TOILET
TOILET
TIME AWAY
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
5:
:5
PM
A1.1C
5-6249
UNIT 'C' FIRST FLOOR
DEMOLITION PLAN
RAM
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
UNIT A UNIT B
UNIT C
1/8" = 1'-0"
UNIT 'C' FIRST FLOOR DEMOLITION PLAN
08.28.2025 BIDS &
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e
ATSMTS ATS
T
T
BFBF
BF
R.
DW
REF.
BF
BF
BF BF BF BF
BF
BF
BFBF
BF
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
A.
B.
C.
DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.
REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION.
INTERIOR STUD WALLS ARE TO USE 3 5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED.
TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED
OTHERWISE.
SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFR.)
EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED
INCLUDING NECESSARY FRAMING, BLOCKING, ETC.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.
PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT, ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL
CONTRACTOR / SITE SUPERVISOR.
COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMMODATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS, ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS
APPROVED BY ARCHITECT.
ALL GUARDRAILS AND HANDRAILS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH ALL REQUIREMENTS OF THE 2015 M.B.C., ANSI ICC A117.1-2017 & AMERICANS WITH DISABILITIES ACT GUIDELINES. THE MOST STRINGENT SHALL
PREVAIL.
PROVIDE MINIMUM CLEARANCES AT ALL DOORS PER DETAILS. SEE G0.01 FOR REQUIREMENTS.
FOR ALL CABINETRY, SEE INTERIOR ELEVATIONS FOR LAYOUTS. FIELD VERIFY CLEAR WIDTHS PRIOR TO FABRICATION.
ALL EXTERIOR BLOCK CORNERS ARE TO BE BULLNOSE BLOCK EXCEPT CONCRETE BLOCK COLUMNS, PIERS AND WALLS TO
RECEIVE TILE - UNLESS NOTED OTHERWISE.
CONTRACTOR TO MAINTAIN / REPAIR RATING OF EXISTING PARTITIONS AS AFFECTED BY DEMOLITION / NEW
CONSTRUCTION. TYPICAL THROUGHOUT.
SEAL ALL PENETRATIONS IN FIRE RATED FLOORS AND WALLS WITH APPROVED FIRESTOPPING.
WHERE SPECIALTY BLOCK IS REQUIRED AT THE SAME HEIGHT ON BOTH SIDES OF A WALL USE (2) SPECIALTY BLOCKS BACK TO BACK TO MAINTAIN THE FINISHED WALL APPEARANCE BOTH SIDES OF THE WALL. COORDINATE WITH STRUCTURAL FOR
LINTELS CONDITIONS PER SPECIFICATIONS.
WALLS TO BE PATCHED WITH LIKE MATERIALS WHERE EXISTING WALLS HAVE BEEN COMPROMISED FROM DEMOLITION. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO REMOVAL AND REINSTALLATION OF CASEWORK AND WALL MOUNTED EQUIPMENT IN ORDER TO ACHIEVE SAID PATCH. IN AREAS WHERE BLOCK OR BRICK HAVE BEEN USED, NEW MASONRY TO BE TOOTHED IN AND MATCH EXISTING. AREAS AND FINISHES IN QUESTION SHALL BE COORDINATED WITH
ARCHITECT.
SEE STRUCTURAL FRAMING PLANS FOR ADDITIONAL WALL REINFORCING REQUIREMENTS. MINIMUM REINFORCING (FOR ALL
WALLS NOT OTHERWISE NOTED ON STRUCTURAL PLANS):
ALL BEARING WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
ALL EXTERIOR WALLS SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
ALL INTERIOR NON-BEARING WALLS OVER 16'-0" HIGH SHALL RECEIVE A MINIMUM REINFORCING OF R1-5-48.
WALL LEGEND
5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.
METAL FRAMING AT 16" O.C. SOUND BATT
FULL HEIGHT OF WALL. WALLS TO BOTTOM
OF DECK UNLESS NOTED OTHERWISE
CMU WALL SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN
(8" TYPICAL U.N.O.)
5/8" GYP. BOARD BOTH SIDES 6" LIGHT GA.
METAL FRAMING AT 16" O.C. SOUND BATT
FULL HEIGHT OF WALL. WALLS TO BOTTOM
OF DECK UNLESS NOTED OTHERWISE
-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN
-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR
GYPSUM WALL BOARD UNLESS NOTED OTHERWISE
BRICK AND CMU WALL W/ 2" SPRAY APPLIED
INSULATION SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN. SEE WALL SECTIONS FOR ADDITIONAL
DETAILS, BANDING, ETC.
(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)
CONCRETE WALL SEE STRUCTURAL
PLANS FOR REQUIRED REINFORCING.
4 7 /8"
7 1 /4"
SE
E
PL
AN
SE
E
PL
AN
SE
E
PL
AN
CLASSROOM
A138
T.
A139
CLOSET
A140
SMALL GROUP
A141
CLASSROOM
A116
CLASSROOM
A119
MECHANICAL
A121
T.
A117
T.
A118
VESTIBULE
A115
CORRIDOR
A122
VESTIBULE
A123
ELEC.
A120
COMPUTER ROOM
A114
CUSTODIAL
A124 STORAGE
A125
RESOURCE
A126
CLASSROOM
A127
CLASSROOM
A130
T.
A128
T.
A129
CLASSROOM
A131
MUSIC CLASSROOM
A134
T.
A132
T.
A133
BOYS T.
A135
GIRLS T.
A136
AUDIO / VISUAL
A112
MEDIA CENTER
A113
VESTIBULE
A137
CORRIDOR
A142
STAFF LAB
A111
OFFICE
A105
WORK ROOM
A107
TOILET
A108
HEALTH
A109
OFFICE
A104
CONFERENCE
A103
RECEPTION
A102
VESTIBULE
A100
COAT CLOSET
A106
CORRIDOR
A101
CORRIDOR
A110
NEW MILLWORK
CIRCULATION
DESK
A2.80
A116A
A119A
A124A A125A A127A A130A
A114A A113A A112A
A112B
A131A A134A
A138A
A101A
W03
W02
W04 W01 W02 W01 W02
A8.01
W01
W07
BL01
A8.01
A4.01
A8.01 23
A8.01 45
A8.01 6
A8.01
2 SIM
A8.01
4 SIM
A8.01
2 SIM
A8.01
A8.01
A8.01
A8.01
A8.01
A8.0112
" W x
" D 8 L
OC
KE
RS
" W x
" D
LO
CK
ER
S
15" W x 12" D
13 LOCKERS
15" W x 12" D
9 LOCKERS
15" W x 12" D
6 LOCKERS
15" W x 12" D
26 LOCKERS
" W x
" D
LO
CK
ER
S
" W x
" D 8 L
OC
KE
RS
" W x
" D
4 L
OC
KE
RS
" W x
" D 4 L
OC
KE
RS
" W x
" D 4 L
OC
KE
RS
" W x
" D
7 L
OC
KE
RS
A2.80
" W x
" D
LO
CK
ER
S
4' - 9" 2' - 6"
3' - 2"
2' - 6" 5' - 1" 3' - 5" 2' - 6" 4' - 6" 2' - 6" 5' - 1"
3'
- 5
1/ 4"
2'
- 6
4'
- 5 3/
4" 2'
- 6
5'
- 1
A117A
A118A
A128A A129A A132A A133A
A140A
A141A
A139A B139A
A4.01
A4.01 4
A120A A121A
INFILL OPENING BELOW
WINDOW, WHERE THE
LOUVER IS REMOVED,
WITH BRICK & BLOCK PER
DETAIL - SEE MECHANICAL
INFILL OPENING
BELOW WINDOW,
WHERE THE
LOUVER IS
REMOVED, WITH
BRICK & BLOCK
PER DETAIL - SEE
MECHANICAL
INFILL OPENING BELOW WINDOW,
WHERE THE LOUVER IS REMOVED,
WITH BRICK & BLOCK PER DETAIL -
SEE MECHANICAL
INFILL OPENING BELOW
WINDOW, WHERE THE
LOUVER IS REMOVED,
WITH BRICK & BLOCK
PER DETAIL - SEE
MECHANICAL
INFILL OPENING BELOW WINDOW,
WHERE THE LOUVER IS REMOVED,
WITH BRICK & BLOCK PER DETAIL -
SEE MECHANICAL
INFILL OPENING
BELOW WINDOW,
WHERE THE
LOUVER IS
REMOVED, WITH
BRICK & BLOCK
PER DETAIL - SEE
MECHANICAL
A113B
A141B
A7.03
TYP
A7.03
TYP
CMU
4"
CMU
4"
4"
8 SIM
A2.80 8
12'W MB / 4'W TB X 4'H
12'W MB / 4'W TB X 4'H
12'W MB / 4'W TB X 4'H
12'W MB / 4'W TB X 4'H
8'W X 4'H MB 8'W X 4'H MB
8'W X
4' H
TB
8'W
X 4'
H
TB
8'W X
4' H
TB
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
'W
M B
/ 4 'W
T B
X 4'H
12'W MB / 4'W TB X 4'H
6'W X
4' H
TB
AS A STANDARD, WHERE 30" DEEP
C-TOPS ARE SHOWN TO
ACCOMODATE 30" DEEP POSTER
UNITS, INSTALL ALL CABS FLUSH
WITH FRONT FACE OF POSTER CAB;
TYP. ENTIRE BUILDINGS, ALL AREAS
OF NEW CASEWORK
1' - 4"
CM
U
TY
P.
4"
4"
6'W X
4' H
TB
2'
- 0
4"
PROJECT NO.
DRAWN
REVIEWED
NO PART OF THIS DRAWING MAY BE
USED OR REPRODUCED IN ANY FORM
OR BY ANY MEANS, OR STORED IN A
DATA BASE OR RETRIEVAL SYSTEM,
WITHOUT PRIOR WRITTEN
PERMISSION OF
ALL RIGHTS RESERVED
c
KEYPLAN
ISSUANCES
GMB COPYRIGHT
Au to de sk
D oc s:
//5
-6
W es t O tta w a W au ka zo o
El em en ta ry Im pr ov em en ts /5
-6
9A
5.
rv t
8/
/2
5:
:2
PM
A2.1A
5-6249
UNIT 'A' FIRST FLOOR PLAN
ERE
AMS
W A
U K
A Z
O O
E
LE
M E
N T
A R
Y S
C H
O O
L
IM
P R
O V
E M
E N
T S
W E
S T
O
TT
A W
A P
U B
LI
C
S C
H O
O
LS
H O
LL
A
N D
M
IC
H
IG
A
N
UNIT A UNIT B
UNIT C 1/8" = 1'-0"
UNIT 'A' FIRST FLOOR PLAN
08.28.2025 BIDS &
CONSTRUCTION
https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=3a179497-5198-462a-845c-7e5620c0684e https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=75533ce3-c48d-4e4f-a7b6-d84736eccc67 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=5c692462-920b-4afd-9d64-d541af8a7cd3 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=5c692462-920b-4afd-9d64-d541af8a7cd3 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=66bd2cc0-5c07-45e4-92a9-39808cf540e5 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=da6f7693-baee-4faa-b635-3f3f4a859497 https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce https://acc.autodesk.com/build/sheets/projects/32f6e317-0640-4d53-b5ae-d461b33d2ddd?moduleId=2d&historyId=4a0969f0-25fb-4201-a2f1-cccfd01d07ce
BF
BF
BF
BF
BF
BF
BF
BFBF
BF
BF
BF
BF
BF
R.BF
WALL LEGEND
5/8" GYP. BOARD BOTH SIDES 3 5/8" LIGHT GA.
METAL FRAMING AT 16" O.C. SOUND BATT
FULL HEIGHT OF WALL. WALLS TO BOTTOM
OF DECK UNLESS NOTED OTHERWISE
CMU WALL SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN
(8" TYPICAL U.N.O.)
5/8" GYP. BOARD BOTH SIDES 6" LIGHT GA.
METAL FRAMING AT 16" O.C. SOUND BATT
FULL HEIGHT OF WALL. WALLS TO BOTTOM
OF DECK UNLESS NOTED OTHERWISE
-FIRE RATINGS AS CALLED FOR ON CODE COMPLIANCE PLAN
-DIMENSIONS GIVEN ARE TO THE FINISHED FACE OF CMU OR
GYPSUM WALL BOARD UNLESS NOTED OTHERWISE
BRICK AND CMU WALL W/ 2" SPRAY APPLIED
INSULATION SEE FLOOR PLANS FOR REQUIRED
WALL REINFORCING. NOMINAL DIMENSIONS
GIVEN. SEE WALL SECTIONS FOR ADDITIONAL
DETAILS, BANDING, ETC.
(3 5/8" BRICK & 8" CMU TYPICAL U.N.O.)
CONCRETE WALL SEE STRUCTURAL
PLANS FOR REQUIRED REINFORCING.
4 7 /8"
7 1 /4"
SE
E
PL
AN
SE
E
PL
AN
SE
E
PL
AN
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
A.
B.
C.
DIMENSIONS GIVEN ARE TO THE FACE OF MASONRY UNITS OR TO THE FINISHED FACE OF METAL STUD PARTITION WALLS.
REFERENCE STRUCTURAL DRAWINGS FOR CONCRETE SLAB SIZES AND SLAB RELATED INFORMATION.
INTERIOR STUD WALLS ARE TO USE 3 5/8" METAL STUD FRAMING UNLESS OTHERWISE NOTED.
TURN UP VAPOR RETARDER MATERIAL AT JOINTS BETWEEN FLOOR SLAB AND FOUNDATION WALL UNLESS NOTED
OTHERWISE.
SEE FOUNDATION PLANS FOR FLOOR SLAB RECESSES FOR TILE, WOOD FLOOR, ETC. (VERIFY RECESS REQUIRED BY MFR.)
EXTEND ALL INTERIOR WALL PARTITIONS (MASONRY OR STUDS) TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE.
REFERENCE STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR ITEMS NOT SHOWN. COORDINATE AS REQUIRED
INCLUDING NECESSARY FRAMING, BLOCKING, ETC.
FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OF ANY CABINETRY, FRAMES, STRUCTURAL ITEMS, ETC.
PROVIDE PAINTED ACCESS PANELS IN WALLS AND CEILINGS TO PROVIDE ACCESS TO CONCEALED ITEMS INCLUDING BUT NOT LIMITED TO VALVES, CONTROLS, MECH. EQUIPMENT, ETC. ACCESS PANELS MAY NOT ALWAYS BE SHOWN ON PLANS. IT IS THE SUB CONTRACTOR RESPONSIBILITY TO DETERMINE LOCATIONS. COORDINATE LOCATIONS WITH OTHER GENERAL
CONTRACTOR / SITE SUPERVISOR.
COORDINATE WALLS WITH COLUMNS AND OTHER ENCASED ITEMS. COLUMNS ARE TO BE CONTAINED WITHIN WALLS. THE FRAMING CONTRACTOR SHALL INCREASE FRAMING SIZE TO ACCOMMODATE COLUMNS, DRAIN LEADERS, PIPING, ELECTRICAL PANELS, ETC. WHERE WALLS REQUIRE EXTRA WIDTH THE ENTIRE WALL SHALL BE WIDENED UNLESS
AP…