This document is a Request for Quotation (RFQ) for the procurement of one (1) fuel measurement system for the Aberdeen Testing Center (ATC). The system is required to measure fuel volume rate, total consumption, fuel density, fuel pressure, and fuel temperature in highly dynamic environments without introducing a pressure drop. Key specifications include a measurement range of -30 to 300 liters/hour, a resolution of 0.044 cubic millimeters, and a maximum data output rate of 100 Hz. The system must interface via CAN bus, analog, digital I/O, and Ethernet. The RFQ is being issued as a commercial item acquisition under simplified procedures, with award to be made to the Lowest Price Technically Acceptable offeror. Quotes are due by August 22, 2024 at 10:00 AM ET and should specify the estimated delivery date, unit prices, and any commercial warranties. The solicitation incorporates various FAR and DFARS clauses by reference.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Purchase Description
Technical Specifications
Fuel Measurement System for Aberdeen Testing Center
GENERAL: Aberdeen Test Center (ATC) is requesting the procurement of one (1) fuel measurement system that is designed for fuel systems with return flow into the tank - diesel application. A critical requirement of the system is to not introduce a pressure drop and therefore not influence the application and measurement. This system is developed using hydraulic components such as heat exchanger, pumps and valves to measure the actual fuel use performance in highly dynamic environments. The system outputs fuel volume rate, total consumption, fuel density, fuel pressure and fuel temperature in an integrated package. The system shall be supplied with all cables, hoses and configuration software.
1. Fuel flow measurement specifications.
a. Measurement range of -30 to 300 liters/hour.
b. Measurement resolution of 0.044 Cubic Millimeters.
c. Flow data rate of 100 samples per second.
2. Fuel Density measurement specifications.
a. Measurement range of 0.6 to 1.2 grams per cubic centimeter.
b. Measurement resolution of 0.0005 grams per cubic centimeter.
c. Density data rate of 1 sample per second.
3. Maximum data output rate of 100 Hz.
4. Powered by DC voltage with input range of 10 volts to 30 volts DC.
5. Operating temperature -40 to 85 deg. C (-40 to 185 deg. F)
6. Interface support
a. CAN bus Input/output
b. Analog
c. Digital I/O - frequency
d. Ethernet
7. Delivery Address:
US Army Aberdeen Test Center 6850 Lanyard Road B358
APG, MD 21005
Point of Contact: