02 Material Description Lists_REVISED_0827.pdf
PDF 146 KB Posted
- Attached to
- Fiber Optic Cable
- Solicitation number
- W91QVN20R0181
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 20R0181_FINAL.pdf | ||
| 01 Amendment01C_20R0181.pdf | ||
| 02 Material Description Lists_REVISED.xlsx | XLSX spreadsheet | |
| 01 SOLICITATION.pdf | ||
| 02 Material Description Lists.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Material Purchase List
NO Item P/N MANUFACTURE DESCRIPTION QTY UNIT U/PRICE EST COST RMK
1 Fiber Optic Cable, SM-144C
Single Mode 144 Core ITU657A1 Fiber Optic Cable Cable Description: Attenuation 0.22dB @1550nm per kilometer, Max 0.2 ps/√km (20 section link) PMD, Attenuation vs. Bending (10mm radius x 1turn) max 0.75 dB @ 1550 nm, Loose tube, Dry cored, PE insulated fiber core, all dielectric single HDPE jacket non-amor, max. 20D Mandrel diameter, 6 Fiber per Bundle , comply ITU-T G.657 and suitable underground conduit use.
Note: A gel free loose tube cable with an HDPE jacket is acceptable
1,300M x 1RL , 6,700M x 1RL, 5,800M x 1RL and 5,200M x 1RL
Vendors shall be required to provide the fiber optic cable test result report when the products are delivered to the designated location
19,000 MT
2 Fiber Optic Cable, SM-96C
Single Mode 96 Core ITU657A1 Fiber Optic Cable Cable Description: Attenuation 0.22dB @1550nm per kilometer, Max 0.2 ps/√km (20 section link) PMD, Attenuation vs. Bending (10mm radius x 1turn) max 0.75 dB @ 1550 nm, Loose tube, Dry cored, PE insulated fiber core, all dielectric single HDPE jacket non-amor, max. 20D Mandrel diameter, 6 Fiber per Bundle, comply ITU-T G.657 and suitable underground conduit use.
Note: A gel free loose tube cable with an HDPE jacket is acceptable
2,800Mx1RL
Vendors shall be required to provide the fiber optic cable test result report when the products are delivered to the designated location
2,800 MT
3 Fiber Optic Cable, SM-48C
Single Mode 48 Core ITU657A1 Fiber Optic Cable Cable Description: Attenuation 0.22dB @1550nm per kilometer, Max 0.2 ps/√km (20 section link) PMD, Attenuation vs. Bending (10mm radius x 1turn) max 0.75 dB @ 1550 nm, Loose tube, Dry cored, PE insulated fiber core, all dielectric single HDPE jacket non-amor, max. 20D Mandrel diameter, 6 Fiber per Bundle , comply ITU-T G.657 and suitable underground conduit use.
Note: A gel free loose tube cable with an HDPE jacket is acceptable
3,200M x 1RL
Vendors shall be required to provide the fiber optic cable test result report when the products are delivered to the designated location
3,200 MT
4 Fiber Optic Cable, SM-24C
Single Mode 24 Core ITU657A1 Fiber Optic Cable Cable Description: Attenuation 0.22dB @1550nm per kilometer, Max 0.2 ps/√km (20 section link) PMD, Attenuation vs. Bending (10mm radius x 1turn) max 0.75 dB @ 1550 nm, Loose tube, Dry cored, PE insulated fiber core, all dielectric single HDPE jacket non-amor, max. 20D Mandrel diameter, 6 Fiber per Bundle , comply ITU-T G.657 and suitable underground conduit use.
Note: A gel free loose tube cable with an HDPE jacket is acceptable
3,600M x 1RL Vendors shall be required to provide the fiber optic cable test result report when the products are delivered to the designated location
3,600 MT
5 Fiber Optic Cable, SM-12C
Single Mode 12 Core ITU657A1 Fiber Optic Cable Cable Description: Attenuation 0.22dB @1550nm per kilometer, Max 0.2 ps/√km (20 section link) PMD, Attenuation vs. Bending (10mm radius x 1turn) max 0.75 dB @ 1550 nm, Loose tube, Dry cored, PE insulated fiber core, all dielectric single HDPE jacket non-amor, max. 20D Mandrel diameter, 6 Fiber per Bundle , comply ITU-T G.657 and suitable underground conduit use.
Note: A gel free loose tube cable with an HDPE jacket is acceptable
6,000M x 1RL and 6,800M x 1RL Vendors shall be required to provide the fiber optic cable test result report when the products are delivered to the designated location
12,800 MT
Fiber Distribution Patch Panel (Rack Type) - 4U
CCH-04U Corning
Brand name or equivalent Corning Cable System CCH-04U Closet Connector Housings - Holds 12 CCH Connector Panels Included CCH Connector Panel (CCH-CP12-59) 6 Duplex SC(12Core)- 12ea with Blank Module-12ea, Included Cable Trays to be able to accommodate 144 cores of the fiber optic cable regardless of the quantity of the cable tray and accommodate 144 cores of the fiber optic cable
12 SET
Fiber Distribution Patch Panel (Rack Type) - 1U
CCH-01U Corning
Brand name or equivalent Corning CCH-01U Closet Connector Patch Panel Housings - Holds 2 CCH Connector Panels, Included CCH Connector Panel (CCH-CP12-59) 6 Duplex SC(12Core)- 2ea with Blank Module - 2ea, Included Cable Tray to be able to accommodate 24 cores of the fiber optic cable regardless of the quantity of the cable tray and accommodate 24 cores of the fiber optic cable.
30 SET
NO Item P/N MANUFACTURE DESCRIPTION QTY UNIT U/PRICE EST COST RMK
8 SM-12 Core SC Pigtail
SM-12 Core SC Pigtail , Fanout Cord-6.6ft.
170 EA
Fiber Optic Splice Closure, 144 Core for Duct
FO Splice Manhole Closure (for 144 Cores)
- In-line type closure
- Either single-loose fibers or ribbon fibers are available
- Either heat-shrink sleeves or mechanical splice sleeves are available
- Robust mechanism for clamping the cable sheath
- Accept additional cables without removal of the sheath retention or disturbing existing splices
- Do not require special tool or equipment for installation.
7 EA
Fiber Optic Splice Closure, 96 Core for Duct
FO Splice Manhole Closure (for 96 Cores)
- In-line type closure
- Either single-loose fibers or ribbon fibers are available
- Either heat-shrink sleeves or mechanical splice sleeves are available
- Robust mechanism for clamping the cable sheath
- Accept additional cables without removal of the sheath retention or disturbing existing splices
- Do not require special tool or equipment for installation.
4 EA
Fiber Optic Splice Closure, 48 Core for Duct
FO Splice Manhole Closure (for 48 Cores)
- In-line type closure
- Either single-loose fibers or ribbon fibers are available
- Either heat-shrink sleeves or mechanical splice sleeves are available
- Robust mechanism for clamping the cable sheath
- Accept additional cables without removal of the sheath retention or disturbing existing splices
- Do not require special tool or equipment for installation.
24 EA
12 MaxCell Fabric Innerduct with 3cells
MaxCell Fabric Innerduct with 3cells
- Fabric breaking tensile > 41.8 kg/cm
- Low coefficient of friction – Dynamic COF of 0.12 on HDPE
- Pull tapes pre-installed in each cell (225 kg, 565 kg, 815 kg, 1,135 kg, or MaxGlide)
- Product pre-lubricated to further lower tension during cable pulls
- Life span of approximately 30 years
- Not affected by climate & Temperature range is – 30 ℃ to 100℃
- UL 2024A LSZH Plenum Rating FR versions for inside plant usage
- Max. cable OD 28mm and Width 64mm, 3 Cells type
- Orange Color and OptiCell
1,000M x 7RL, 800M x 1RL and 500M x 1RL
8,300 MT
13 1 LOT
Shipping Charge
Door to Door shipping 1st SIG BDG, C4I Distribution Center, Bldg S-1043, Camp Humphreys, Pyeongtaek City, Repulic of Korea 17981,
File details come from the government source that posted it. Updated .