A02_Drawing_files___127523___ARCH.pdf
PDF 832 KB Posted
- Attached to
- Repair building #400, Cp Casey
- Solicitation number
- W91QVN-17-R-0096
About this file
Drawing ARCH
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A02_Drawing_files___127523___Title.pdf | ||
| A02_Drawing_files___127523___MECH.pdf | ||
| A02_Drawing_files___127523___ELEC.pdf | ||
| A02_Drawing_files___127523___CIVIL.pdf | ||
| Solicitation_for_W91QVN-17-R-0096.docx | DOCX document | |
| A02_Submittal_Register___127523.xls | XLS spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A-1
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
SCALE:
MANUFACTURES INDICATED.
PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE
COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.
ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER REPRESENTATIVE (COR).
CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS
FOR APPROVAL.
CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR
CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE
SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD
8.
FOR APPROVAL.
CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR
OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR
SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE
2.
3.
4.
5.
6.
7.
CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL
AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION
OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE
APPROPRIATE TEMPORARY SUPPORTS SHOULD BE CONSTRUCTED PRIOR TO DEMOLITION
9.
10.
11.
12.
13.
14.
NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD NO. 595b, COLORS.
COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY AND COLOR
COMMENCEMENT OF FLOOR TILE WORK.
ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO
DETAILS AND GET APPROVAL FROM COR. BEFORE FABRICATION AND INSTALLATION.
CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW
ADDITIONAL COST TO THE GOVERNMENT.
EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM WITHOUT
THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING, HEATING,
ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE REQUIRED FOR
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVE/REINSTALL ANY OBSTRUCTED
GENERAL NOTES
REPAIR BUILDING S-400
CAMP CASEYYI, SC
127523
WALL : 2.00 SM. DEG K/W
ROOF : 3.35 SM. DEG K/W
R-VALUE FOR INSULATION:
10,973 10,973
3,1731,2003,1001,2002,300
,6
,7
,4
,6
,7
,4
4,8776,096
10,973
4,8776,096
10,973
EXST/REMOVAL FLOOR PLAN
SCALE:
NEW FLOOR PLAN REMOVAL EXISTING WALL
REMOVE EXISTING DOOR
LEGEND
REMOVE EXISTING CONC SLAB
& DOOR FRAME
WINDOW &
WINDOW FRAME
DOOR & DOOR
FRAME
50 MET STUD WALL
STORAGE ROOM-2
STORAGE ROOM-1
1/50 1/50
FEC
D1
D2
W1 W1
W1
W1
W1 W1
200 THK CONC WALL
AND GENERAL NOTES
EXST/REMOVAL & NEW FLOOR PLAN
SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.
STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003
15.
LOAD ANALYSIS TO COR FOR APPROVAL.
CONTRACTOR SHALL SUBMIT STRUCTURAL SHOP DRAWINGS INCLUDING BUILDING
A-2
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
1.
2.
3.
4.
6.
7.
8.
9.
5.
SCOPE OF WORKS (ARCHITECTURAL WORKS)
REPAIR / MAINTENANCE (K) WORKS
10.
11.
12.
13.
14.
15.
SCOPE OF WORKS (ARCHITECTURAL WORKS)
NEW CONSTRUCTION (L) WORKS
1.
REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEWS.
METAL DOOR
THERMAL INSULATED
AL SLIDING WINDOW W/
EIFS
CONCRETE RAMP (TYP)
SCALE:
ELEVATION-1
SCALE:
ELEVATION-2
SCALE:
ELEVATION-4
SCALE:
ELEVATION-3
S-400S-400
RAMP (TYP)
CONCRETE
STOOP (TYP)
CONCRETE
1/100 1/100
1/1001/100
PROTECTED
PROTECTED
PROTECTED
METAL ROOFING
W/ INSUL ON VR
(TYP)
METAL ROOFING
W/ INSUL ON VR
(TYP)
PROTECTED
METAL GUTTER
(TYP)
PROTECTED
METAL
DOWNSPOUT
(TYP)
BUILDING
IDENTIFICATION
(TYP)
THERMAL INSULATED
INSECT SCREEN (TYP)
PROTECTED
METAL FASCIA
W/ INSUL ON VR
(TYP)
PROTECTED
METAL FASCIA
W/ INSUL ON VR
(TYP)
PROTECTED
METAL FASCIA
W/ INSUL ON VR
(TYP)
METAL ROOFING
W/ INSUL ON VR
(TYP)
PROTECTED
METAL GUTTER
(TYP)
CONC SPLASH
BLOCK (TYP)
REPAIR BUILDING S-400
CAMP CASEYYI, SC
127523
& SCOPE OF WORKS
ELEVATIONS
CEILING SUSPENSION SYSTEM AS SHOWN ON FLOOR PLANS AND FINISH SCHEDULE.
REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL) CEILING INCL.
APPLY EPOXY COATING WITH NON SLIP GRITS ON FLOORS AS SHOWN ON INTERIOR FINISH SCHEDULE.
INSTALL NEW TALL BUILT IN COATED METAL SHELVING AS SHOWN ON FLOOR PLANS, SECTIONS AND NOTES.
SPACE + 6 THK TINTED LOW-E TEMPERED GLASS AS SHOWN ON FLOOR PLANS AND WINDOW SCHEDULE.
TYPE WINDOWS INCLUDING INSULATING GLASS WITH 8.75 THK CLEAR LAMINATED GLASS + 12 THK AIR
REPLACE DETERIORATED EXISTING WINDOWS INCL INSECT SCREEN WITH NEW ALUMINUM THERMAL BREAKER
FINISH SCHEDULE.
APPLY SCP(SKIM COAT PLASTER) ON CONCRETE WALLS AS SHOWN ON FLOOR PLANS, SECTIONS & INTERIOR
CWB AS SHOWN ON FLOOR PLANS AND SECTIONS.
REPLACE DETERIORATED EXISTING CONCRETE SLAB WITH NEW INCLUDING WWF, VAPOR BARRIER AND
FOUNDATIONS, REINFORCEMENT BARS AND EIFS AS SHOWN ON FLOOR PLANS, ELEVATIONS AND SECTIONS.
REPLACE DETERIORATED EXISTING EXTERIOR WALLS WITH NEW CONCRETE INCLUDING CONCRETE
FLOOR PLANS, ELEVATIONS & SECTIONS.
INSULATIONS, PROTECTED METAL FASCIA, SOFFIT AND PROTECTED METAL ROOF LINER AS SHOWN ON
REPLACE DETERIORATED EXISTING ROOF WITH NEW PROTECTED METAL ROOF INCLUDING METAL FRAMES, ELEVATIONS & SECTIONS.
GUTTERS AND DOWNSPOUTS INCLUDING CONCRETE SPLASH BLOCKS AS SHOWN ON FLOOR PLAN,
REPLACE DETERIORATED EXISTING RAIN GUTTERS AND DOWNSPOUTS WITH NEW PROTECTED METAL RAIN
REPLACE EXTERIOR BUILDING IDENTIFICATIONS WITH NEW AS SHOWN ON ELEVATIONS AND DETAIL.
FLOOR PLANS AND DETAIL DRAWING.
REPLACE DETERIORATED EXISTING FIRE EXTINGUISHER CABINET(FEC) WITH NEW AS SHOWN ON NEW
AS SHOWN ON NEW FLOOR PLANS AND DOOR SCHEDULE.
REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE SETS
SECTIONS (NATURAL COLOR, OAK).
REPLACE DETERIORATED EXISTING WOODEN HEAD & SILL FOR ALL WINDOWS WITH NEW AS SHOWN ON
& SECTIONS.
PAINT ON ALL INTERIOR SURFACES INCLUDING CEILING & WALL AS SHOWN ON INTERIOR FINISH SCHEDULE
AND ELEVATIONS.
REPLACE DETERIORATED EXISTING CONCRETE RAMP AND STOOP WITH NEW AS SHOWN ON FLOOR PLANS
16.
SCHEDULE.
REPLACE DETERIORATED EXISTING VCB WITH NEW AS SHOWN ON FLOOR PLAN AND INTERIOR FINISH
A-3
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
V A
R
C L
G
H
T
HD16 @200 O.C.
4-HD16
HD13 @400 O.C.
VERT BARS
HD13 @300 O.C.
HORIZ BARS
L A
P
FL
SCALE: 1/50
CROSS SECTION-1
SCALE: 1/50
CROSS SECTION-2
WORKING
POINT
FL
L A
P
HD16 @200 O.C.
4-HD16 3
C L
H
T
HD13 @400 O.C.
VERT BARS
HD13 @300 O.C.
HORIZ BARS
VAPOR BARRIER
150THK CWB
EXST CONC
100THK SLAB ON GRADE
W/ MW10(#8)-150x150 WWF
VAPOR BARRIER
150THK CWB
EXST CONC
1.
METAL SHELVING NOTES
2.
FABRICATION AND INSTALLATION
COORDINATE WITH USING AGENCY FOR INSTALLATION BEFORE
AND USING AGENCY FOR APPROVALAS. AND CONTRACTOR SHALL
FOR TALL BUILT IN COATED METAL SHELVING TO ENGINEERING DIV
THE CONTRACTOR SHALL PREPARE AND SUBMIT SHOP DRAWINGS
METAL SHELVING
ON FLOOR WITH ANCHOR BOLTS.
OR ABOVE WITH COATED METAL SHELVING AND FIXED
TALL BUILT IN METAL SHELVING MUST CARRYING 300KG
PROTECTED
PROTECTED
PROTECTED METAL
ON 50 MET STUD
WOODEN HEAD
& SILL (OAK)
PAINT SCP
ON CONC
METAL ROOFING
W/ INSUL ON VR
(TYP)
ROOF LINER
FINISH PER
SCHEDULE
METAL ROOFING
W/ INSUL ON VR
(TYP)
15 THK GWB
@ 400 OC(MAX)
ON CONC WALL
BACKFILL W/
SATISFACTORY MATERIAL
BACKFILL W/
SATISFACTORY MATERIAL
REPAIR BUILDING S-400
CAMP CASEYYI, SC
127523
METAL SHELVING NOTES
CROSS SECTIONS AND
A-4
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
IN
S
ID
E
B O
X
D
IM
PULL (TYP)
SIDE)-TYP
METAL DOOR
6 DIA METAL
SCREW (3-PER
SCHEDULE
FLAT TRIM
FINISH PER
(ALL AROUND)
WOOD SHIM
V
E R
IF
Y
3C SECTIONELEVATION3B
(OUTSIDE TRIM DIM)
(INSIDE BOX DIM) W/ METAL LATH
FLAT TRIM
CONC FILL
IN
S
WOOD SHIM
(ALL AROUND)
DOOR PULL
CASING BEAD
(ROUGH OPENING)
PLAN3A
3C 3B
(TYP)
METAL
DOOR PULL
TEMPERED SAFETY
METAL TRIM
T
F F
L
F I R E
E X T I N G U I S H E R
GLASS
W/ METAL LATH
CONC FILL
(INSIDE BOX DIM)
30 30
45300
(INSIDE BOX DIM)
IN
S
(OUTSIDE TRIM DIM)
O
U T S
T R
3 THK X 50 W
SST STRAP
@ 900 OC
(TYP)
9 DIA EXP BOLT
75 W X 150 H X 5 THK
SST PLATE (TYP)
EXT INSUL &
FNSH SYSTEM
PROTECTED
METAL DS
(150 x 100) 6 DIAx80 RUST
PROOF CAP
SCREW & NUT
W/WASHER (TYP) 1.5 THK X 50 W
PROTECTED METAL
DS STRAP HANGER
@ 900 OC (MAX)
NUMBER & SIZE
NUMBER
NOTE
3. LOCATION FOR SEE ELEVATION.
BUILDING
2. NUMBER ARE TWO PLACES PER EACH
WITH THE BASE CIVIL ENGINEER.
; CONTRACTOR SHALL VERIFY
1. BUILDING IDENTIFICATION
V E
R
IF
Y B
Y
NUMBER
BUILDING
IDENTIFICATION
S-400
SCALE: N/A
DOWNSPOUT DETAIL
SCALE: N/A
BUILDING IDENTIFICATION
SCALE: N/A
FIRE EXTINGUISHER CABINET DETAILS
PAINT SCP
PAINT SCP
PAINT SCP
EXT FIELD
IS TO MATCH
LETTER COLOR
WALL COLOR
MATCH
COLOR IS TO
BACKGROUND
ROOF COLOR
7070 760
S-400
REPAIR BUILDING S-400
CAMP CASEYYI, SC
127523
DETAILS
FL
A-5
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ARCHITECTURAL
INTERIOR FINISH SCHEDULE
FLOOR BASE WALLS CEILING
REMARKS
FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT
PAINT VAR
MATERIAL & COLOR SCHEDULE
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
EXST
MAT'L
NEW
MAT'L
NEW
MAT'L
EXST
1.
2.
MANUFACTURERS STANDARD MUST APPROACH.
TO INDICATE THE COLOR WHICH THE
IS NOT REQUIRED. THE SELECTIONS SERVE ONLY
AN EXACT MATCH OF THE MANUFACTURERS COLOR
INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
IDENTIFICATION PURPOSES ONLY AND ARE NOT
MANUFACTURERS' COLORS LISTED ARE FOR
3.
FLOOR MATERIAL/COLOR
PT-1
FINISH SCHEDULE NOTES
ROOM NAMESROOM NOS
CONC GWB101 EPOXY EP-1 GWB
COLORS SHALL BE APPROVED BY USING AGENCY.
SELECTION OF INTERIOR PAINT AND FACTORY APPLIED
APPROVED BY THE COR OR USING AGENCY.
THE RLFC AREA. EXTERIOR COLOR SCHEME AS
APPLIED COLORS SHALL BE IN ACCORDANCE WITH
SELECTION OF EXTERIOR PAINT AND FACTORY
REMARKS
DOOR DIMENSION
WIDTH
MATERIAL
D1
DOOR
TYPE
DOOR
NOS.
ROUGH OPENING
WIDTH HEIGHT
HDW
SET
THICKHEIGHT NO (HR)
RATED
FIRE
LOUVERGLAZING
CUT
UNDER
FRAME
D2
DOOR
DOOR / WINDOW / LOUVER SCHEDULE
A -21501930 2250 1830 44.5 1 - -
B - -2 - -1016 2250
METAL METAL
METALMETAL
(2 EA)
P L A N
DOOR S E C T I O N
STEEL TUBE
WELDED TO
STEEL PLATE
50 x 50 x 6THK
FOUNDATION
STEEL PLATE
STEEL TUBE
CONCRETE
170 x 170 x 6THK
WELDED TO
EYEBOLT
HOOK &
DOOR
HOOK & EYEBOLT
STEEL TUBE
CONC)
GALV STEEL
80x80x3.2 THK
50 x 50 x 6 THK STEEL
80x80x3.2 THK
WALL TYPE BUMPER L02101
GALV STEEL TUBE
(FILLED W/CONC)
PLATE WELDED TO
WALL TYPE BUMPER L02101
YELLOW STRIPS
BLACK BACKGROUND
TUBE (FILLED W/
250X250
SURFACE
ROOFING
FLASHING
FASCIA
SOFFIT
DOOR & FRAME
HANDRAIL
MATERIAL
ROOF LINER
STEEL
STEEL PIPE
COLOR
CHOCOLATE
COLOR NO.
20095
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
CHOCOLATE
20095
20095
20095
20095
20095
REMARKS
WALL EIFS
WALL CMU
BEAM/COL CONC
STAIR CONC
SAND-STONE
SAND-STONE
SAND-STONE
SAND-STONE
23617
23617
23617
23617
PROTECTED METAL
PROTECTED METAL
PROTECTED METAL
EXTERIOR COLOR SCHEDULE-1
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
FS 595B
ELEVATION
SCALE: N/A
DOOR STOP & HOLDER DETAILS
EP-1
OR APPROVED EQUAL
ABRASIVE GRAIN FINISH
WITH NONSLIP GRIT
TOP: DHDC-6500T
MID: DHDC-6500M
PRIMER: DHDC-6500P
NOROO EPOXY
EPOXY PAINT
10001200ALC - -------AL
DOOR/WINDOW SCHEDULE & DETAILS
INTERIOR FINISH SCHEDULE,
10mmTHK PEJ
W/SEALANT (TYP)
PAINT 2450PAINT PT-1PT-1CONC GWB102 EPOXY EP-1 GWB
STORAGE ROOM-1
STORAGE ROOM-2
CONC
CONC
SCP ON
CONC
GWB ON
METAL LINER
PROTECTED
GWB
F.F 20095
W1 MET DOOR
THERMAL INSULATED
A B
MET DOOR
THERMAL INSULATED
(ANODIZED DARK BRONZE)
(THERMAL BREAK TYPE)
W/ INSECT SCREEN
C
FIX
SLIDING AL WINDOW
930 2150 44.5
ASTRAGAL
HDW-1
HINGES 8111 114X114, NRP
1 LOCKSET 1000-1 F07
FLUSH BOLT LO40812
DOOR STOP & HOLDER
HDW-2
1 THRESHOLD J32100
CLOSER CO2011
KICK PLATE J102, SST1
LOCKSET 1000-1 F081
WEATHER STRIP & SEAL1
HINGES 8111 114X114, NRP
DOOR STOP & HOLDER
WEATHER STRIP & SEAL1
3.
APPROVAL
AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR
CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR
CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.
ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE
AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4
ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;
5.
6.
4.
HEAT GAIN AND FIRERATED.
WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE
BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE
WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL
1.
2.
FABRICATION AND INSTALLATION
SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE
DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS
THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL
DOOR & WINDOW NOTES
WINDOW BLIND SHOULD BE EQUIPPED TO ALL EXTERIOR WINDOWS.
( SHGC : MAX 0.4 )
+ 6 THK TINTED LOW-E TEMPERED GLASS
+ 12 THK AIR SPACE
: 8.75 THK CLEAR LAMINATED GLASS
TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS
DOOR / WINDOW / HARDWARE SCHEDULE / NOTES
COR.
INSTALL HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO
COLOR, & QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHOULD
AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE,
AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.
MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY
REPAIR BUILDING S-400
CAMP CASEYYI, SC
127523
BASE MATERIAL/COLOR
OR APPROVED EQUAL
P110, BROWN
ROPPE
VINYL COVE BASEVCB-1
WALL MATERIAL/COLOR
PT-1
OR APPROVED EQUAL
LATEX/SEMIGLOSS
NOROO NR7066
PAINT COLOR
CEILING MATERIAL/COLOR
PT-1
OR APPROVED EQUAL
LATEX/SEMIGLOSS
NOROO NR7066
PAINT COLOR
VCB VCB F.F VCB-1
VCB VCB F.F VCB-1CONC
OR RAMP
CONC STOOP
| 127523-Repair Bldg S-400, Cp Casey-A-1 |
| 127523-Repair Bldg S-400, Cp Casey-A-2 |
| 127523-Repair Bldg S-400, Cp Casey-A-3 |
| 127523-Repair Bldg S-400, Cp Casey-A-4 |
| 127523-Repair Bldg S-400, Cp Casey-A-5 |
File details come from the government source that posted it. Updated .