GENERAL NOTES
1.
2.MOUNTING HEIGHTS ABOVE FLOOR SHALL BE AS FOLLOW UNLESS OTHERWISE
NOTED ON THE DRAWING.
LIGHTING FIXTURE SEE LIGHTING FIXTURE SCHEDULE
PANELBOARD SEE SPECIFICATION
SAFETY SWITCH 1524mm TO CENTER OF THE ENCL
RECEPTACLE,TELEPHONE OUTLET 305mm TO CENTER OF THE ENCL
MOTOR CONTROLLER 1524mm TO CENTER OF THE ENCL
1676mm TO CENTER OF THE ENCL
2286mm TO CENTER OF BELL
3.
4.
6.THE SOIL RESISTANCE TO GROUND FOR THE ELECTRICAL AND COMMMUNICATION
SYSTEMS SHALL BE 25 OHMS OR LESS. THE SOIL RESISTANCE TEST SHALL BE
7.
COORDINATED WITH THE CENTRAL FIRE DEPARTMENT SO THAT
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
ON CEILINGDETECTOR
1372mm TO CENTER OF STATIONMANUAL PULL STATION
5.
CONDUCTED BY THE CONTRACTOR TO OBTAIN THE REQUIRED SOIL RESISTANCE.
INDICATEDS 2 #12AWG IN 16C
INDICATEDS 3 #12AWG IN 16C
INDICATEDS 4 #12AWG IN 16C
A GREATER NUMBER OF WIRES ARE INDICATED AS FOLLOWS;
1219mm TO CENTER OF THE ENCLWALL SWTICH
CONDUIT UNLESS OTHERWISE INDICATED.
ALL EQUIPMENT CONTROL WIRING SHALL BE #14 AWG. "TW" IN 16C
AND LOCATION OF THE F/A ANTENNA WITH THE CENTRAL FIRE DEPARTMENT
THE CONTRACTOR SHALL SUBMIT THE SHOP DRAWING FOR THE MOUNTING
TO TRANSMIT THE ALARM RADIO SIGNAL WAVE WITHOUT ANY OBSTRUCTION.
DETAIL OF THE F/A ANTENNA, AND COORDINATE THE MOUNTING HEIGHT
F/A EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE EQUIPMENT SHOULD BE COMPATIBLE WITH THE MAIN EXISTING
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
SCOPE OF WORKS
LEGEND, GENERAL NOTES AND
E-1
1.
SCOPE OF WORK
F/A & MNS EQUIPMENT IN THE CENTRAL FIRE DEPARTMENT.
THE MANUFACTURER AND MODEL OF NEW F/A& MNS EQUIPMENT SHALL BE
F/A &MNS CONTROL
COMBO. SPEAKER & STROBE
3.
12.
13.
14.
5.
4.
A. REPAIR/MAINTENANCE ( K )
10.
11.
8.
9.
15.
SINGLE POLE TOGGLE SWITCH, 15A-120V
L E G E N D
FLEXIBLE CONDUIT W/CONNECTORS
LIGHTING
WIRING
POWER
INTERIOR
S
SYMBOL DESCRIPTION
DESCRIPTION
DESCRIPTION
T
J
THERMOSTAT (UNDER MECH. ITEM)
JUNCTION BOX
SYMBOL
SYMBOL
F FAN MOTOR (UNDER MECH. ITEM)
SAFETY SWITCH
C CONTROL CIRCUIT
AND GOVERNMENT INSTALLED
GOVERNMENT FURNISHED
GFGI
WEATHERPROOFWP
LA LIGHTNING ARRESTER
EXPLOSIONPROOFEP
DISTRIBUTIONDIST
GROUND FAULT PROTECTIONGFP
A AMPERE
AC ALTERNATING CURRENT
AF/AT AMPERE FRAME/AMPERE TRIP
AWG AMERICAN WIRE GAUGE
BC BARE COPPER
BLDG BUILDING
BRKR BREAKER
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CONN CONNECTION
CT CURRENT TRANSFORMER
DET(S) DETAIL(S)
DIAG DIAGRAM
DISC DISCONNECT
DWG(S) DRAWING(S)
EA EACH
EM EMERGENCY
ENCL ENCLOSURE
EXST EXISTING
F/A FIRE ALARM
FL FLOOR
FLUOR FLUORESCENT
FXTR FIXTURE
GEN GENERATOR
GND GROUND
HP HORSE POWER
HZ HERTZ
INCAND INCANDESCENT
INSTL INSTALLATION
J-BOX JUNCTION BOX
K KILO
KV KILO VOLT
KVA KILO VOLT AMPERE
LTG LIGHTING
MAG MAGNETIC
MAX MAXIMUM
MIN MINIMUM OR MINUTE
MTG MOUNTING
NO NUMBER
O/H OVER HEAD
PH PHASE
PNLBD PANELBOARD
PRIM PRIMARY
PWR POWER
Q'TY QUANTITY
RCPT RECEPTACLE
REQ'D REQUIRED
SCHED SCHEDULE
SEC SECONDARY
SPEC SPECIFICATION
STD STANDARD
SW SWITCH
TEL TELEPHONE
TYP TYPICAL
U/G UNDERGROUND
V VOLT
VA VOLT AMPERE
W WATT
W/ WITH
XFMR TRANSFORMER
& AND
PANELBOARD
3S
HOMERUN CIRCUIT TO PANELBOARD
TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDING
ABBREVIATION
THE COTNRACTOR SHALL SUBMIT A SHOP DRAWING OF HVAC SYSTEM
IN ACCORDANCE WITH SEQUENCE OF OPERATION INDICATED ON THE
MECHANICAL DRAWINGS.
ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES 2-#12AWG
WIRES IN 16C CONDUIT UNLESS OTHERWISE INDICATED.
THE GROUNDING CONDUCTORS SHALL BE SEPARATELY PROVIDED FOR
ELECTRICAL EQUIPMENT UNLESS OTHERWISE INDICATED ON THE DRAWING.
CEILING.
ALL WIRING SHALL BE CONCEALED ABOVE CEILING WHEN THE ROOM HAS
CATV BEFORE CONSTRUCTION.
CONTRACTOR SHALL COORDINATE WITH AREA MP, DO IMO, SIGNAL BRIGADE,
AND GOVERNMENT ACCEPTANCE.
PANELBOARD DOOR, REQUIRED BEFORE FINAL BUILDING INSPECTION
CONTRACTOR SHALL MAKE CIRCUIT CHARTS AND ATTACH THEM TO
FIRE CODE AND SPECIFICATIONS.
OF THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE,
ALL ELECTRICAL WORK SHALL CONFORM TO THE CURRENT REQUIREMENTS
OR RENOVATION.
CONDITION AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION
THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFING ALL EXISTING
FIXTURE A MINIMUM DISTANCE OF 458mm.
FIRE ALARM DETECTORS SHALL BE LOCATED TO CLEAR ANY LIGHTING
FMCP
FTR
ANTENNA
AUXILIARY
DESCRIPTION
F
SYMBOL
ADDRESSABLE FA MANUAL PULL STATION
WP
F M
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
MOUNTED TYPE
F/A & MASS NOTIFICATION SPEAKER "WP" WALL
STROBES
WALL MOUNTED SPEAKER /COMBO. (FA+MNS)VISUAL
CONNECTION
BUILDING TRANSMITTER UNIT FOR FIRE ALARM
SYSTEM
F FIRE ALARM SYSTEM CIRCUIT
T
F/M
TYPE
SINGLE RECEPTACLE, 2P-3W-20A-125V, GROUNDING
L
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
W/EMERGENCY BATTERY UNIT
L
W/EMERGENCY UNIT
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
ON LTG SCHEDULE
LED LIGHTING FIXTURE, RATED WATT & TYPE OF MTG
L
L
UNITS.
CERTIFICATE FROM MANUFACTURER FOR LED LIGHTING FIXTURES AND POWER
CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE 10YEARS WARRANTY
16.
THE GRADING LINE OF NEW DUCTS WILL BE LIMITED TO THE
WIDTH OF DUCT EXCAVATION.
AND AFTER INSTALLATION OF ELECTRICAL SYSTEM.
TO THEIR ORIGINAL CONDITION AND OPERATION DURING
ALL DAMAGED AREA INCLUDING SODDING, UTILITIES, STRUCTURES
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING
OPERATING CONSOLE AND ASSOCIATED WIRING AND CONDUIT.
MICROPHONE, SPEAKER (WATTAGE AS REQ'D) DEVICE, LOCAL
ANTENNA, VISUAL SIGNAL STROBES (15 OR 75 CANDELA),
HEAT DETECTORS & RELAY MODULE, BUILDING TRANSMITTER,
NOTIFICATION SYSTEM PANEL, MANUAL PULL STATION, SMOKE &
NEW ADDRESSABLE FIRE ALARM CONTROL AND MASS
REPLACE DETERIORATED FIRE ALARM CONTROL SYSTEM WITH
3-WAY SWITCH, 15A-120V
AND WALL
WIRING CONCEALED OR EXPOSED IN/ON THE CEILING
WIRING FOR TELEPHONE/LAN LINE
FOR BAY AREA LIGHTS.
REPAIR EXIST PANELBOARD "Lb" AND LIGHTING CONTACTORS 2.
TYPE OF MTG ON LTG SCHEDULE
EXTERIOR LIGHTING FIXTURE, RATED WATT &
FAULT PROTECTED TYPE
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED
FAULT PROTECTED TYPE"WP"
DUPLEX RECEPTACLE, 2P-3W-20A-125V, GROUNDED "WP"
FOR HVAC SYSTEM WITH NEW.
JUNCTION BOXES, CONTROL SYSTEM, WIRES AND CONDUITS
REPLACE DETERIORATED EXISTING SAFETY SWTICHES,
BREAKERS, AND ASSOCIATED WIRING & CONDUIT WITH NEW.
REPLACE EXISTING RECEPTACLES AND COVER PLATES, CIRCUIT
SWITCHES, WIRES AND CONDUITS WITH NEW.
LIGHTS, EXTERIOR LIGHTS, TOGGLE SWITCHES, 3-WAY
REPLACE DETERIORATED EXISTING LIGHTING FIXTURES, EXIT
WIRING TO UPSTAIR/DOWNSTAIR
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
WARRIOR BASETAK, YS
107389
6.
W/COVER PLATES AND ASSOCIATED WIRING AND CONDUIT.
TERMINAL CABINET W/ ACCESSORIES, TELEPHONE OUTLETS
REPLACE EXTERIOR TELECOMMUNICATION LINE, TELEPHONE
SS
SS
NS-5
- E2
SCALE: 1 : 50
METAL BASE.
COLD WEATHER BALLAST, WHITE POWDER COATED,
COMPACT FLUORESCENT BULB INCLUDED 0 DEG. F
120V, ONE 28W DOUBLE TWIN-TUBE, WARM WHITE
"B1"
"MPB"
"MDPB"
S
S
S
S
BEDROOM
BEDROOM
MECH
E-2
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
- E2
SCALE: NOT TO SCALE
LIGHTING FIXTURE DETAIL
1ST FLOOR LIGHTING PLAN &
TO REMAIN
EXISTING PANEL BOARD
LIGHTING FIXTURE DETAILS
1ST FLOOR LIGHTING PLAN
L L L L L L L L
LL
L L L
LL
LLL
L L L L
CEILING SURFACE/PENDANT MOUNTED LIGHT EMITTING DIODE (LED)
FIXTURE, 1PH, 120/277V, 50W, WITH CONVERTER, ACCESSORIES, UL
NS-4a & NS-4bNS-3a & 3b
CEILING SURFACE/PENDANT MOUNTED LIGHT EMITTING DIODE (LED)
FIXTURE, 1PH, 120/277V, 45W, WITH CONVERTER, ACCESSORIES, UL
L
L
LISTED(NS-3a)& EM UNIT(NS-3b)
LISTED(NS-4a)& EM UNIT(NS-4b)
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
WARRIOR BASETAK, YS
107389
1MA-KORO STD. DET. 40-06-04
S S
LED
LED
UNIT
EMERGENCY BATTERY
FLUOR NS-5
- E3
SCALE: 1 : 50
"B2"
S
S
S
S
NS-4b
NS-4a 18
BEDROOM
BEDROOM
NS-3a 45 1
NS-4a 50
NS-4b 50
4 2
XL1
XL1
R O O M
NO NAME TYPE WATT SHT
REMARKS
TYPE
LAMP
QTY MOUNTING HEIGHTS
CEILING SURFACE
150mm ABOVE DOORLED
BEDROOM
MECH ROOM
LED
BEDROOM
EXTERIOR
CEILING SURFACE
CEILING SURFACE
CEILING SURFACE
150mm ABOVE DOOR
150mm ABOVE DOOR
SUSPENSION MTD
E-3
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
TO REMAIN
EXISTING PANEL BOARD
2ND FLOOR LIGHTING PLAN
L L L L L L L L
L L
LLLLLLLL
L LL L L L
LED
LED
LED
LED
NS-3b 45 SUSPENSION MTD1
UNIT
EMERGENCY BATTERY
UNIT
EMERGENCY BATTERY
LIGHTING FIXTURE SCHEDULE
FIXTURE SCHEDULE
2ND FLOOR LIGHTING PLAN & LIGHTING
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
- E4
SCALE: 1 : 50
COVER PLATE WITH NEW (TYPICAL)
REPLACE EXISTING DUPLEX RECEPTACLE &
WITH NEW
RECEPTACLE & COVER PLATE (WP)
REPLACE EXISTING GFCI DUPLEX
"B1"
BEDROOM
BEDROOM
E-4
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
B1-5,7
B1-4.6
1ST FLOOR POWER PLAN
ERV
ERV
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
EXISTING PANELBOARD "MPB"
EXISTING PANELBOARD "MDPB"
OHPU
OHPU
ROOM THERMOSTAT (MECH. ITEM)
T
T
(TYPCIAL)
HEAT PUMP SYSTEM CONTROL PANELS
CONTROL WIRE TO BE CONNECTED TO
MECH
#8(G) IN 54 mm C.
REPLACE W/ NEW 4-AWG#4 &
NEMA 3R ENCL. (TYPICAL OF 2EA)
3PST-240VAC-100A W/70A FUSEx3EA, REPLACE W/NEW SAFETY SWITCH, (TYPICAL)
3PH, 208V, 15.87KW (MECH. ITEM)
OUTDOOR SPLIT SYSTEM HEAT PUMP UNIT,
1 2
3 4
5 6
NABC
GND
S/N
PANELBOARD "MPB" PANELBOARD "B1"
PANELBOARD "B2" SPARE
~ CIRCUIT BREAKER (TYP. OF 2EA)
REPLACE W/NEW 3P-100AF-70AT
HEAT PUMP UNIT-1 HEAT PUMP UNIT-2
#8(G) IN 54 mm C.
REPLACE W/ NEW 4-AWG#4 &
- E4
#8(G) IN 54 mm C.
4-AWG#4 &
REPLACE W/ NEW
EXIST/NEW PNLBD "MDPB" LOAD SCHEDULE
MDPB-1 MDPB-2
20A, GROUNDING TYPE (TYPICAL)
NEW SINGLE RECEPTACLE 2P-240VAC,
(TYPICAL)
1PH, 208V, 80W (MECH. ITEM)
INDOOR SPLIT SYSTEM HEAT PUMP UNIT,
(TYPICAL)
1PH, 208V, 460W (MECH. ITEM)
ENERGY RECOVERY VENTILATION UNIT,
BREAKER
100AF-60AT CIRCUIT
REPLACE W/NEW 3P-
#8(G) IN 36 mm C.
4-AWG#6&
REPLACE W/ NEW
#8(G) IN 36 mm C.
4-AWG#8&
REPLACE W/ NEW
BREAKER
100AF-50AT CIRCUIT
REPLACE W/NEW 3P-
3P
LUGS
100A
MPB-8
MPB-7
- E4
3 EXIST/NEW PNLBD "MPB" LOAD SCHEDULE
NAB
GND
S/N
C G
INDOOR SPLIT SYSTEM HEAT PUMP UNIT ENERGY RECOVERY VENTILATION UNIT,
EXIST LOAD ELEC UNIT HEATER
MPB-2
J
2.3KW(MECH ITEM)
ELEC UNIT HEATER,1PH,208V,
#12(G) IN 16 mm C.
REPLACE W/ NEW 2-AWG#12 &
#12(G) IN 16 mm C.
REPLACE W/ NEW 2-AWG#12 & CIRCUIT BREAKER (TYP. OF 3EA)
REPLACE W/NEW 2P-100AF-20AT
"MDPB"&"MPB" LOAD SCHEDULE
1ST FLOOR POWER PLAN, EXIST/NEW PNLBD
"WP"
C
C
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
- E5
SCALE: 1 : 50
T
COVER PLATE WITH NEW (TYPICAL)
REPLACE EXISTING DUPLEX RECEPTACLE &
ROOM THERMOSTAT (MECH. ITEM)
"B2"
BEDROOM
BEDROOM
E-5
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
B2-5,7
B2-4,6
2ND FLOOR POWER PLAN
ERV
ERV
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
HPU
T
(TYPCIAL)
HEAT PUMP SYSTEM CONTROL PANELS
CONTROL WIRE TO BE CONNECTED TO
(TYPICAL)
1PH, 208V, 80W (MECH. ITEM)
INDOOR SPLIT SYSTEM HEAT PUMP UNIT,
(TYPICAL)
1PH, 208V, 460W (MECH. ITEM)
ENERGY RECOVERY VENTILATION UNIT,
20A, GROUNDING TYPE (TYPICAL)
NEW SINGLE RECEPTACLE 2P-240VAC,
NA B
GND
S/N
C G
3P
100AF
60AT
BREAKER (3P-100AF-60AT)
REPLACE W/NEW MAIN CIRCUIT
BREAKER( 2P-100AF-20AT)
REPLACE W/NEW CIRCUIT
BREAKER( 2P-100AF-20AT)
REPLACE W/NEW CIRCUIT
#12(G) IN 16 mm C.
REPLACE W/ NEW 2-AWG#12 &
B2-10
B2-4,6
B2-9
- E5
INDOOR SPLIT SYSTEM HEAT PUMP UNIT ENERGY RECOVERY VENTILATION UNIT,
#8(G) IN 36 mm C.
REPLACE W/ NEW 4-AWG#6 &
EXIST/NEW PNLBD "B2" LOAD SCHEDULE
"B2" LOAD SCHEDULE
2ND FLOOR POWER PLAN, EXIST/NEW PNLBD
C
C
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
MECH
- E6
SCALE: 1 : 50
"B1"
BEDROOM
BEDROOM
E-6
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
S
SB
S
SB
S
SB
S
SB
S
SB
S
SB
W P
F M
F
F
D
TS
J J
FS
J
PS
TS
J
F M
C P
F T
R
TS
J
TS
J
W P
F M
F F
TO FMCP
TO FMCP
TO FMCP
FMCP
BATTERY CHARGER, POWER MODULE PANEL(AS REQ'D)
SYNCHRONIZATION CONTROL MODULE, DIGITAL VOICE
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL,
24VDC, BUILT-IN ADDRESSABLE POINTS MODULES
AS REQUIRED, PROGRAMMABLE MODULE & RELAYS,
POWER MODULE AS REQ.D LCD ANNUNCIATOR,
SURFACE MOUNTED COMBINED ADDRESSABLE
MODULE, POWER SUPPLY, MICROPHONE, BATTERY,
AND AMPLIFIER(AS REQ'D), NEMA 1 ENCL
FTR BUILDING TRANSMITTER W/BATTERY &
BATTERY CHARGER, NEMA 1 ENCL
W/MOUNTING BARCKET
OMNI-DIRECTION TYPE
FIRE ALARM ANTENNA
WALL MOUNTED SPEAKER (WATTAGE
SHALL BE DE-RATED AS REQUIRED)
(15 CANDELA MINIMUM, AMBER STROBE
W/WORDS "ALERT") VISUAL SIGNAL STROBES
W/WORDS "FIRE" + MNS-AMBER STROBE
AS REQ'D)/COMBO. (FA-CLEAR STROBE
ADDRESSABLE MANUAL PULL STATION
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
TEMPER SWITCH W/ADDRESSABLE
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
FLOW SWITCH W/ADDRESSABLE
J
PS
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
PRESSURE SWITCH W/ADDRESSABLE
SPEAKER (WATTAGE AS REQ'D)
FIRE ALARM/MASS NOTIFICATION
WALL MOUNTED "WP" TYPE,
INCLUDING MICROPHONE &
LOCAL OPERATING CONSOLE(LOC)LOC
PUSH BUTTONS, etc.
* ADDITIONAL LEGEND
S
SB
ADDRESSABLE SMOKE DETECTOR W/SOUNDER BASE
J
FS
TS
J
F
WP
F M
1ST FLOOR FIRE ALARM CONTROL & MASS NOTIFICATION SYSTEM PLAN
MASS NOTIFICATION SYSTEM PLAN
1ST FLOOR FIRE ALARM CONTROL &
F F F F
F
F
FF
F F
F
F
F/M F/M
F/M F/M
F
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
- E7
SCALE: 1 : 50
"B2"
BEDROOM
BEDROOM
E-7
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
ELECTRICAL
S
SB
S
SB
S
SB
S
SB
S
SB
S
SB
S
SB
S
SB
F
FF F
TO FMCP
L O
C
(15 CANDELA MINIMUM, AMBER STROBE
ADDRESSABLE MANUAL PULL STATION
INCLUDING MICROPHONE &
LOCAL OPERATING CONSOLE(LOC)LOC
PUSH BUTTONS, etc.
S
SB
ADDRESSABLE SMOKE DETECTOR W/SOUNDER BASE
SHALL BE DE-RATED AS REQUIRED)
WALL MOUNTED SPEAKER (WATTAGE
W/WORDS "ALERT") VISUAL SIGNAL STROBES
W/WORDS "FIRE" + MNS-AMBER STROBE
AS REQ'D)/COMBO. (FA-CLEAR STROBE
F
* ADDITIONAL LEGEND
2ND FLOOR FIRE ALARM CONTROL & MASS NOTIFICATION SYSTEM PLAN
MASS NOTIFICATION SYSTEM PLAN
2ND FLOOR FIRE ALARM CONTROL &
F
F F F F
FFFFFF
F/M F/M
F/M
F/M
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
A
B C D
E F G H
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
SHEET OF
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
2#12 IN 16C(FOR POWER)
12#14 IN 21C(FOR SIGNAL)
WHICH DEVICE IS LOCATED
(TYPICAL)
ROOM NUMBER
BATTERY CHARGER, POWER MODULE PANEL(AS REQ'D)
SYNCHRONIZATION CONTROL MODULE, DIGITAL VOICE
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL,
24VDC, BUILT-IN ADDRESSABLE POINTS MODULES
AS REQUIRED, PROGRAMMABLE MODULE & RELAYS,
POWER MODULE AS REQ.D LCD ANNUNCIATOR,
NOT TO SCALE
MANUAL PULL STATION
(TYPICAL)
W/MOUNTING BRACKET
LIGHTNING ARRESTER
OMNI-DIRECTION TYPE
W/CONNECTORS IN 16C
COAXIAL CABLE
GROUND CONDUCTOR
#6 "BC" IN 21C
W/WEATHER-PROOF ENCLOSURE
WITH WELDING CONNECTION
GROUND ROD, COPPER CLAD
STEEL, 19mmdia x 3000mmLG
BUILDING
TRANSMITTER
G ~
GROUND ROD, COPPER CLAD
#6, "BC" IN 21C
GROUNDING SYSTEM
CONN TO BLDG ELECTRODE
STEEL, 19mmdiax3000mmLG
WITH WELDING CONNECTION AND
2#12 & 1#12(G) IN 16C
G
SG
CONTROL PANEL (FMCP)
COMBINED FIRE ALARM/
1st FLOOR
102101
SURFACE MOUNTED COMBINED ADDRESSABLE
MODULE, POWER SUPPLY, MICROPHONE, BATTERY,
AND AMPLIFIER(AS REQ'D), NEMA 1 ENCL
MASS NOTIFICATION
15.
"FIRE" AND W/CLEAR LENS.
1.
"ALERT" IN RED LETTER AND W/AMBER LENS.
SAFE PATH FACILITY COMMUNICATIONS OR APPROVED EQUAL.
STROBES FOR FIRE ALARM SHALL BE MARKED
STROBES FOR MASS NOTIFICATION SHALL BE MARKED
FOR ABBREVIATION, LEGEND, AND GENERAL NOTES MASS NOTIFICATION SYSTEM SHALL BE SIMILAR TO WHEELOCK10.
5) EMERGENCY WEATHER CONDITIONS APPROPRIATE FOR THE LOCAL AREA
4) EVACUATION OF THE BUILDING USING EXITS OTHER THAN THE NORMAL MAIN ENTRANCE/EXIT
2) INTRUDER/HOSTILE PERSON SIGHTED WITHIN/AROUND THE BUILDING
1) BOMB THREAT OR ACTUAL BOMB WITHIN/AROUND THE BUILDING
ARE IN ENGLISH AND HANGUL AT LEAST FOR THE FOLLOWING ITEMS.
THE MASS NOTIFICATION SYSTEM SHALL BE ENSURED THAT PRERECORDED MESSAGES
WITH THE MANUFACTURER'S LISTED INSTALLATION REQUIREMENTS AND WIRE COUNT.
SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION DEVICE LOCATIONS IN ACCORDANCE
THE APPLICABLE CODE, SPECIFICATIONS AND MANUFACTURER'S EQUIPMENT LISTING.
IS THE MINIMUM REQUIRED AND THE FINAL QUANTITY SHALL BE IN ACCORDANCE WITH
THE MASS NOTIFICATION SYSTEM IS CONCEPTUAL. THE NUMBER OF DEVICES SHOWN19.
3) OCCUPANTS DIRECTED TO TAKE COVER WITHIN THE BUILDING
6) "ALL CLEAR" MESSAGE
PER DRAFT UFC 4-021-01.
18.
21.
20.
14. ADDITIONAL RELAY IS PROVIDED AS REQUIRED.
SYNCHRONIZED. AUDIBLE APPLIANCES SHALL PROVIDE THE
SPECIFICATION SECTION 28.31.64.00.31(FA) AND NFPA 72.
APPROVED.
ARCHITECTURAL FEATURES.
LOCATIONS IN ACCORDANCE WITH THE MANUFACTURER'S
IN ACCORDANCE WITH THE APPLICABLE CODE, SPECIFICATIONS
THE MINIMUM REQUIRED AND THE FINAL QUANTITY SHALL BE
AND READY TO USE. THE NUMBER OF DEVICES SHOWN IS
BE PROVIDED WITH CLASS "A" MODULES
HORIZONTAL AND 305mm VERTICALLY.
TRANSMITTER AND ANTENNA.
PANEL COVER.
BREAKER AND/OR DISCONNECT SWITCH.
FOR THE FIRE ALARM AND DETECTION SYSTEM.
AUDIBILITY CALCULATION, WIRE SIZE, NO. OF WIRES
NOTES:
SHALL BE RESPONSIBLE FOR PROVIDING FIRE ALARM
THE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTRACTOR
FIRE ALARM CIRCUIT SHALL BE IDENTIFIED BY A RED LETTER
"FIRE ALARM CIRCUIT" ON THE DEDICATED POWER CIRCUIT
CIRCUIT SHALL BE INDICATED ON THE FIRE ALARM CONTROL
THE POWER CIRCUIT NUMBER DEDICATED TO FIRE ALARM4.
3.
2.
COAXIAL CABLE SHALL BE ONE PIECE BETWEEN BUILDING5.
SYSTEM SHALL BE SEPARATED BY A MINIMUM OF 1220mm
INCOMING AND OUTGOING CLASS "A" RACEWAY OF FA6.
7. ALL CLASS "A" EXCEPTIONS IN NFPA 72, 6.4.2.2.2 ARE
PROHIBITED FOR ALL IDC, NAC AND SLC.
ALL TAMPER SWITCHES, FLOW SWITCHES, PRESSURE
SWITCHES AND NON-ADDRESSABLE INITIATION DEVICES SHALL
COORDINATE THE EXACT DEVICE LOCATIONS WITH ELECTRICAL
AND MECHANICAL SYSTEM EQUIPMENT AND BUILDING
ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM
ALL AUDIBLE APPLIANCES WITHIN THE BUILDING AND ALL
VISUAL APPLIANCES WITHIN THE SAME ROOM SHALL BE
STANDARD TEMPORAL PATTERN, NFPA 72.
SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH
9.
11.
12.
13.
SHALL COMPLETE THE DESIGN AND INSTALL THE SYSTEM
8.
LISTED INSTALLATION REQUIREMENTS AND WIRE COUNT.
SHOP SUBMITTAL TO SHOW DETAILED INSTALLATION DEVICE
AND MANUFACTURER'S EQUIPMENT LISTING.
COMPLETE THE DESIGN AND INSTALL THE SYSTEM COMPLETE
THE FIRE ALARM SYSTEM IS CONCEPTUAL. THE CONTRACTOR
ALSO CONDUITS SHALL BE RUN AWAY AT LEAST 900mm
(3-FEET) FROM HVAC, HOT & COLD WATER PIPING.
SURFACE MOUNTED BUILDING
201 202
SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH SPECIFICATION SECTION 28.31.76.00.31
(MNS) AND NFPA 72.
FA SYSTEM SHALL OVERRIDE THE MASS NOTIFICATION SYSTEM.
2nd FLOOR
(WATTAGE AS REQ'D)
(TYPICAL)
"WP" WALL MOUNTED TYPE
F/A & MASS NOTIFICATION SPEAKER
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
PRESSURE SWITCH W/ADDRESSABLE
FIRE ALARM ADDRESSABLE
ELECTRICAL
E-8
SEE SHEET NO E-1.
TO FMCP (TYPICAL)
LOC
202201
TRANSMITTER W/BATTERY &
BATTERY CHARGER, RELAY
FROM MNS NEMA 1 ENCL
BOARD W/CONTROLWIRING
FIRRE ALARM ANTENNA
J
PS TS
J J
FS TS
J
TS
J
TS
J
103 103103 103
SBSB
201201
SBSB
202202
SBSB
202202
SBSB
201201
103103
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
FLOW SWITCH W/ADDRESSABLE
(UNDER MECH ITEM)
MODULE FOR SPRINKLER SYSTEM
TEMPER SWITCH W/ADDRESSABLE
SYSTEM DIAGRAM
FIRE ALARM/MASS NOTIFICATION
FIRE ALARM/MASS NOTIFICATION SYSTEM DIAGRAM
SMOKE W/SOUNDER BASE (TYPICAL)
ADDRESSABLE COMBINED PHOTOELECTRIC
TO B1-11
S
SB
F
S
SB
S
SB101101
D
S
SB
F
F
F
F
SMOKE W/SOUNDER BASE (TYPICAL)
ADDRESSABLE COMBINED PHOTOELECTRIC
ROOF
EXT
WP
F M
EXT
WP
F M
(TYPICAL)
SEE NOTE 2. BELOW
FOR NO & SIZE OF WIRE
WALL MOUNTED SPEAKER (WATTAGE AS REQ'D)
/COMBO. (FA+MNS) VISUAL STROBES
(CANDELA AS REQ'D) (TYPICAL)
7) TEST
S
SB
F
F
S
SB
102 103
F
F
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
BEDROOM
BEDROOM
BEDROOM
- E9
SCALE:
1ST FLOOR TELEPHONE PLAN
1 : 100
- E9
SCALE:
2ND FLOOR TELEPHONE PLAN
1 : 100
CAT-6, 1-4PAIR, #24AWG IN 16C
TO BE TERMINATED AT 110 BLOCK IN
TTC (TYPICAL)
W/COVER PLATE & LUG
CAT-6, 8-PIN (RJ45 TYPE)
SINGLE MODULAR JACK
(TYPICAL)
CAT-6, 1-4PAIR, #24AWG IN 16C
TTC (TYPICAL)
W/COVER PLATE & LUG
CAT-6, 8-PIN (RJ45 TYPE)
SINGLE MODULAR JACK
(TYPICAL)
TO BE TERMINATED AT "TELEPHONE CABINET"
1-4PAIR, #24AWG, CAT-6, TEL WIRE IN 16C
ROOF
2nd FL.
G
1st FL.
SINGLE CAT-6, MODULAR JACK
8-PIN(RJ-45 TYPE),
WITH COVER PLATE & LUG
(TYPICAL)
#6 "BC" IN 21C
GROUNDING BUSBAR
CONN TO
UNPROTECTED TERMINAL BLOCK (4-100PAIR)
PROTECTED TERMINAL BLOCK (1-25PAIR) &
CABINET "TTC" (762mmWx610mmHx152mmD)
TTC
NOT TO SCALE
TELEPHONE SYSTEM DIAGRAM
101101101
,TMGB, RECEPTACLE AND ACCESSORIES
OF TELEPHONE SYSTEM FOR APPROVAL
CONTRACTOR SHALL SUBMIT SHOP DRAWING
NEW 1-25 PAIR #24 AWG IN 103mm dia C.
TMGB
NEMA 1 ENCL.
SURFACE MOUNTED TELEPHONE
MAIN PANELBOARD "MDPB"
102 102 102 102
IN MECH RM 103 (TYPICAL)
201201201201 202 202 202 202
TO BE TERMINATED AT TERMINAL BLOCK IN
(762mmWx610mmHx152mmD)
TELEPHONE TERMINAL CABINET "TTC"
- E9
NEW 1-25 PAIR #24 AWG IN 103mm dia C.
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
BEDROOM
MECH
T T
C
P
TELEPHONE SYSTEM DIAGRAM
1ST, 2ND FLOOR TELEPHONE PLAN &
BLDG NO. S-256
REPAIR TRANSIENT LIVING QUARTER,
WARRIOR BASETAK, YS
107388
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
WARRIOR BASETAK, YS
E-9
256 263
206T
SYMBOL BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
SHEET OF
DESCRIPTION CHK'D
REVISIONS
IMCOM
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
ELECTRICAL
BLDGS & GROUNDS DESIGNED BY
SUBMITTED BYUTILITIES
FIRE & EMERGENCY SVC APPROVED BY
CHIEF, ENGR'G DIVSAFETY
DES USING AGENCY
ENERGY MANAGERENVIRONMENT
REVIEWED BY
F
T
600mmW x 600mmH x 300mmD
WEATHER PROOF TYPE
NEW PULL BOX
P
T T C
C
RM
MECH
SCALE 1:200
NEW TELEPHONE TERMINAL CABINET
7.
EXOTHERMIC WELDING, LISTED COMPRESSION TWO-
1. THE CONNECTIONS OF THE BONDING CONDUCTOR FOR
TELECOMMUNITIONS TO THE TMGB SHALL UTILIZE
HOLE LUGS, SUITABLE AND EQUIVALENT TWO-HOLE
NOTES:
STAMP FACING OUT" TO ENSURE THAT THEY CAN BE
"PLYWOOD WILL BE INSTALLED WITH FIRE RATED
3. TEST RESULTS WILL BE PROVIDED IAW THE MOST RECENT
REVISION OF THE ANSI/TIA/EIA-568.
4. LABEL ALL DROPS IAW TIA/EIA-606-A.
LUGS ARE PREFERRED.
FIELD VERIFIED.
2. PLYWOOD SHALL BE FIRE-RATED.
6. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DETAIL
1 EXIST/NEW EXTERIOR TELECOMMUNICATION LINE PLAN
5. LABEL ALL GROUNDS IAW I3A.
E-10
LINE PLAN
EXIST/NEW EXTERIOR TELECOMMUNICATION
RESTORATION.
DUCT IN NEW 103mm dia C.) AND GROUND
(1-25 PAIR #24 AWG W/3x4"FABRIC INNER
NEW UNDERGROUND TELEPHONE CABLE
PRIOR TO CONSTRUCTION.
TELEPHONE TERMINAL CABINET FOR GOVENRMENT APPROVAL
BLDG NO. S-257
REPAIR TRANSIENT LIVING QUARTER,
WARRIOR BASETAK, YS
107389
E10
UNDERGROUND 1-25 PAIR, #24AWG TEL CABLE W/SPLICE KIT.
RESPONSIBLE TO VERIFY EXIST SITE CONDITION AND PROVIDE
ESTIMATED FOR BIDDING PURPOSES ONLY. CONTRACTOR IS
WIRING AND WIRE COUNTS AS SHOWN ON THIS DRAWING ARE
EXIST MANHOLE AND TYPE OF SLICE KIT TO INSTALL NEW
TELEPHONE CABLE SHALL BE COORDINATED WITH BASE
SIGNAL COMPANY.
NEW SPLICE KIT 1-25PAIR AWG#24
EXIST COMM MANHOLE/
| 257_E-1 |
| 257_E-2 |
| 257_E-3 |
| 257_E-4 |
| 257_E-5 |
| 257_E-6 |
| 257_E-7 |
| 257_E-8 |
| 257_E-9 |
| 257_E-10 |