Text version
T M 1 1 - 5 8 5 5 - 2 9 9 - 1 2 & P
T E C H N I C A L M A N U A L
OPERATOR’S AND UNIT
M A I N T E N A N C E M A N U A L
( INCLUDING REPAIR PARTS
AND SPECIAL TOOLS LIST)
TEST SET, ELECTRONIC SYSTEMS
T S - 4 3 4 8 / U V
(NSN 6625-01-323-9584) (EIC: N/A)
D I S T R I B U T I O N S T A T E M E N T C . Distr ibut ion author ized to U.S. Government agencies and their contractors. This publ icat ion is required for administrat ion and operat ional purposes, as determined 10 October 1990. Other requests for this document shal l be referred to: Commander, US Army Communicat ions- E l e c t r o n i c s C o m m a n d e n d F o r t M o n m o u t h , A T T N : A M S E L - L C - L M - L T , F o r t M o n m o u t h , N J 0 7 7 0 3 - 5 0 0 7 .
D E S T R U C T I O N N O T l C E - For unclassi f ied, l imited documents, destroy by any method that wi l l prevent disclosure of contents or reconstruct ion of the documen t .
HEADQUARTERS, DEPARTMENT OF THE ARMY
1 MAY 1994
WARNING
Do not dispose of alkaline battery BA–3090/U in fire. Do not short circuit or otherwise tamper with the battery. Re-turn for disposal in accordance with DLSC Handbook 41601.
FIRST AID
If first aid is required, administer in accordance with
FM 21–11, FIRST AID FOR SOLDIERS.
A/(B blank)
Technical Manual Headquarters, DEPARTMENT OF THE ARMY
Washington, DC No. 11–5855–299–12&P* 1 May 1994
OPERATOR’S AND UNIT
MAINTENANCE MANUAL
(INCLUDING REPAIR PARTS
AND SPECIAL TOOLS LIST)
TEST SET, ELECTRONIC SYSTEMS
TS-4348/UV
(NSN 6625-01-323-9584) (EIC: N/A)
REPORTING ERRORS AND RECOMMENDING
IMPROVEMENTS
You can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter or DA Form 2028 (Recommended Changes to Publications and Blank Forms) direct to Com-mander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-LC–LM–LT, Fort Mon-mouth, NJ. 07703-5007. A reply will be furnished direct to you.
DISTRIBUTION STATEMENT C. Distribution authorized to U.S. Government agen-cies and their contractors. This publication is required for administration and opera-tional purposes, as determined 10 October 1990. Other request for this document shall be referred to: Commander, US Army Communications-Electronics Command and Fort Fort Monmouth, ATTN: AMSEL-LC-LM-LT, Fort Monmouth, NJ 07703-5007.
DESTRUCTION NOTICE- For unclassified, Iimited documents, destroy by any meth-od that will prevent disclosure of contents or reconstruction of the document.
*This manual supersedes TM 11-5855-299-12&P, dated 15 November 1992.
i/(ii blank)
TABLE OF CONTENTS
CHAPTER 1
SECTION 1
1–1 1–2 1–3
1-4
1–5
1-6
1–7
SECTION II
1–8 1-8.1 1–8.2 1–8.3 1-8.4 1–8.5
Title
HOW TO USE THIS MANUAL . . . . . X
INTRODUCTION . . . . . . . . . . . . . . 1-1
GENERAL INFORMATION . . . . . . 1-1
SCOPE . . . . . . . . . . . . . . . . . . . . . . . 1-1
PURPOSE . . . . . . . . . . . . . . . . . . . . . 1–2
CONSOLIDATED INDEX OF
ARMY PUBLICATIONS AND
BLANK FORMS . . . . . . . . . . . . ...1-2
MAINTENANCE FORMS,
RECORDS, AND REPORTS . . . . . . 1–2
DESTRUCTION OF ARMY
ELECTRONIC MATERIEL . . . . . . 1–2
REPORTING EQUIPMENT
IMPROVEMENT
RECOMMENDATIONS (EIR). . . . . . 1–3
WARRANTY . . . . . . . . . . . . . . . . . . 1–3
EQUIPMENT DESCRIPTION . . . . 1–3
DESCRIPTION . . . . . . . . . . . . . ...1-3
Case, Elec . . . . . . . . . . . . . . . . . . . . . 1-6 Operator’s Manual . . . . . . . . . . . . . . 1-6 Adapter, Resilient . . . . . . . . . . . . . . . 1-6 Adapter, Set Connector. . . . . . . . . . . 1-6 Adapter, Viewer . . . . . . . . . . . . . . . . 1-6 iii
TABLE OF CONTENTS (Continued) Paragraph 1–8.6 1–8.7 1–8.8 1–9 1–9. 1 1–9.2 1–10
CHAPTER 2
2–1
SECTION I
2-2
SECTION II
2-3 2–3. 1 2–3.2 2-3.3 2-3.4 2-4
SECTION III
Title Page Test Set, Unit Ashy . . . . . . . . . . . . . . 1–7 Lens Paper . . . . . . . . . . . . . . . . . . . . 1–7 Case, Optical Inst . . . . . . . . . . . . . . . 1–7
CHARACTERISTICS . . . . . . . . . . . 1–7
Mechanical Characteristics . . . . . . . . 1–7 Electrical Characteristics . . . . . . . . . 1–8
MODEL DIFFERENCES . . . . . . . . 1–8
OPERATING INSTRUCTIONS . . . 2-1
GENERAL . . . . . . . . . . . . . . . . . . . . 2-2
DESCRIPTION AND USE OF
OPERATOR’S CONTROLS
AND INDICATORS . . . . . . . . . . . . . 2-2
OPERATOR’S CONTROLS AND
INDICATORS . . . . . . . . . . . . . . . . . 2-2
PREVENTIVE MAINTENANCE
CHECKS AND SERVICES . . . . . . . 2-4
GENERAL . . . . . . . . . . . . . . . . . . . .2-4
Before You Operate . . . . . . . . . . . . . 2-5 While You Operate . . . . . . . . . . . . . . 2–5 After You Operate . . . . . . . . . . . . . . . 2–5 If Your Equipment Fails To Operate . 2–5
ROUTINE CHECKS . . . . . . . . . . . . 2–5
OPERATION UNDER USUAL
CONDITIONS . . . . . . . . . . . . . . . . . 2–6
iv
2-5 2-6 2-7 2-7.1 2–7.2 2-7.3 2-8
2-8.1 2-8.2 2–8.3
CHAPTER 3
SECTION I
3-1
SECTION II
3-2
SECTION III
3-3 3-4 3-5
3-6
Page
UNPACKING . . . . . . . . . . . . . . . . 2-6
BATTERY INSTALLATION . . . . 2-6
ADAPTER INSTALLATION . . . . 2-7
Adapter, Resilient . . . . . . . . . . . . . 2–9 Adapter, Set Connector . . . . . . . . 2–11 Adapter, Viewer . . . . . . . . . . . . . . 2–13
NIGHT VISION DEVICE
TESTING . . . . . . . . . . . . . . . . . . . 2-15
Testing Night Vision Goggles . . . 2-16 Testing Weapon Sights . . . . . . . . . 2–21 Testing Driver’s Viewers . . . . . . . 2–23
OPERATOR MAINTENANCE . . 3-1
LUBRICATION . . . . . . . . . . . . . . . 3-1
LUBRICATION . . . . . . . . . . . . . . . 3-l
TROUBLESHOOTING . . . . . . . . 3- 1
TROUBLESHOOTING TABLE . . 3-1
MAINTENANCE . . . . . . . . . . . . . 3-2
OPTICS CLEANING . . . . . . . . . . 3-2
ADAPTER, VIEWER REPAIR . . 3-3
BATTERY COMPARTMENT
GASKET REPLACEMENT . . . . . 3-4
LENS CAP REPLACEMENT . . . 3-6
v
Title
APPENDIX A
A–1 A–2 A-3
APPENDIX B
SECTION I
B–1 B–2 B–3
B-4
B-5
SECTION II
SECTION III
SECTION IV
vi
Title Page
REFERENCES . . . . . . . . . . . . . . .A–1
SCOPE . . . . . . . . . . . . . . . . . . . . . . A-l REFERENCE LIST . . . . . . . . . . . . A-l
TECHNICAL MANUALS . . . . . . A-1
MAINTENANCE ALLOCATION
CHART . . . . . . . . . . . . . . . . . . . . . B-l
INTRODUCTION . . . . . . . . . . . . . B-1
GENERAL . . . . . . . . . . . . . . . . . . . B-1
MAINTENANCE FUNCTIONS . B-1
EXPLANATION OF COLUMNS
IN THE MAC, SECTION II . . . . . B–3
EXPLANATION OF COLUMNS
IN TOOL AND TEST
EQUIPMENT REQUIREMENTS,
SECTION III . . . . . . . . . . . . . . . . . B-4
EXPLANATION OF COLUMNS
IN REMARKS, SECTION IV . . . . B–5
MAINTENANCE ALLOCATION
CHART . . . . . . . . . . . . . . . . . . . . . B-6
TOOL AND TEST EQUIPMENT
REQUIREMENTS . . . . . . . . . . . . B-7
REMARKS . . . . . . . . . . . . . . . . . . B-8
APPENDIX C
SECTION I
C-1 C–2 C-3
SECTION II
SECTION III
APPENDIX D
SECTION I
D-1 D-2 D-3
SECTION II
APPENDIX E
SECTION 1
E–1
Title Page
COMPONENTS OF END ITEM
AND BASIC ISSUE ITEMS . . . . . C-1
INTRODUCTION . . . . . . . . . . . . . C-1
SCOPE . . . . . . . . . . . . . . . . . . . . . .C–1
GENERAL . . . . . . . . . . . . . . . . . . . C-1
EXPLANATION OF COLUMNS . C–2
COMPONENTS OF END ITEM . C-5
BASIC ISSUE ITEMS . . . . . . . . . C–7
ADDITIONAL
AUTHORIZATION LIST . . . . . . . D-1
INTRODUCTION . . . . . . . . . . . . . D-1
SCOPE . . . . . . . . . . . . . . . . . . . . . . D-1
GENERAL . . . . . . . . . . . . . . . . . . . D-1
EXPLANATION OF LISTING . . . D-1
ADDITIONAL
AUTHORIZATION LIST . . . . . . . D-2
EXPENDABLE/DURABLE
SUPPLIES AND MATERIALS . . E-1
INTRODUCTION . . . . . . . . . . . . . E-1
SCOPE . . . . . . . . . . . . . . . . . . . . . .E–1
vii
E-2
SECTION II
APPENDIX F
SECTION I
F–1 F-2 F–3
F-4
F-5 F-6
F-7
Title Page
EXPLANATION OF COLUMNS . E-1
EXPENDABLE/DURABLE
SUPPLIES AND MATERIALS
LIST . . . . . . . . . . . . . . . . . . . . . . .. E-3
REPAIR PARTS AND SPECIAL
TOOLS LIST . . . . . . . . . . . . . . . ..F–1
INTRODUCTION . . . . . . . . . . . .. F-l
SCOPE . . . . . . . . . . . . . . . . . . . . ..F–1
GENERAL . . . . . . . . . . . . . . . . . .. F-1
EXPLANATION OF COLUMNS
(SECTION II AND III) . . . . . . . .. F-2
EXPLANATION OF COLUMNS
(SECTION IV) . . . . . . . . . . . . . .. F-9
SPECIAL INFORMATION . . . . F–11
HOW TO LOCATE REPAIR
PARTS . . . . . . . . . . . . . . . . . . .. F–11
ABBREVIATIONS . . . . . . . . . .. F-12
viii
SECTION II
GROUP 00
GROUP 01
GROUP 02
SECTION III
SECTION IV
Title Page Fig. No.
REPAIR PARTS LIST F–1–1
TEST SET,
ELECTRONIC
SYSTEMS
TS-4348/UV . . . . . . F–l–1 1
TEST SET, UNIT
ASSEMBLY . . . . . . F–2–1 2
ADAPTER
ASSEMBLY . . . . . . F–3-1 3
SPECIAL TOOLS
LIST (NOT
APPLICABLE)
CROSS-REFERENCE
INDEXES . . . . . . . . . F–I-1
NATIONAL STOCK
NUMBER INDEX . . . F–I–1
PART NUMBER
INDEX . . . . . . . . . . . . F-I-2
FIGURE AND ITEM
NUMBER INDEX . . . F-I-3
ix
HOW TO USE THIS MANUAL
USAGE
You must familiarize yourself with the entire maintenance procedure before beginning the maintenance task. Read and follow all warning notices.
MANUAL OVERVIEW
The contents of each chapter are listed at the beginning of each chapter. This listing includes the paragraph number, paragraph title, and the page number.
SPECIAL FEATURE
A locator is provided on the left–hand border of the back cover. This gives the location of the information most fre-quently used. To find the topic OPERATING INSTRUC- TIONS, open the manual to the correct page by using the black tab on the side of the manual that lines up with the top-ic OPERATING INSTRUCTIONS.
x
CHAPTER 1
INTRODUCTION
SECTION I
1–1 1–2 1-3
1-4
1-5
1-6
1–7
SECTION II
1–8 1-9 1–9. 1 1–9.2 1-10
GENERAL INFORMATION . . . . . . 1-1
SCOPE . . . . . . . . . . . . . . . . . . . . . . . 1-1
PURPOSE . . . . . . . . . . . . . . . . . . . . . 1–2
CONSOLIDATED INDEX OF
ARMY PUBLICATIONS AND
BLANK FORMS . . . . . . . . . . . . . . .1–2
MAINTENANCE FORMS,
RECORDS, AND REPORTS . . . . . . 1-2
DESTRUCTION OF ARMY
ELECTRONIC MATERIEL. . . . . . . .1–2
REPORTING EQUIPMENT
IMPROVEMENT
RECOMMENDATIONS (EIR) . . . . 1–3
WARRANTY . . . . . . . . . . . . . . . . . . 1–3
EQUIPMENT DESCRIPTION . . . . 1-3
DESCRIPTION . . . . . . . . . . . . . . . . 1–3
CHARACTERISTICS . . . . . . . . . . . 1–7
Mechanical Characteristics . . . . . . . . 1–7 Electrical Characteristics . . . . . . . . . 1–8
MODEL DIFFERENCES . . . . . . . . 1-8
Section I. GENERAL INFORMATION
1-1 SCOPE
This manual is for your use in operating and maintaining the Test Set, Electronic Systems, TS-4348/UV. The Test Set, Electronic Systems will be referred to in this manual as Test Set.
1-1
1-2 PURPOSE
The Test Set is a hand-held, battery powered unit for field testing Night Vision Devices (NVD’s). It is used by field personnel to check the optical performance at both low and high light levels to determine the operational readiness of an NVD.
1-3 CONSOLIDATED INDEX OF ARMY
PUBLICATIONS AND BLANK FORMS
Refer to the latest issue of DA Pam 25–30 to determine whether there are additions, changes, or additional publica-tions pertaining to the equipment.
1-4 MAINTENANCE FORMS, RECORDS, AND
REPORTS
a. Reports of Maintenance and Unsatisfactory Equipment. Department of the Army forms and procedures used for equipment maintenance will be those prescribed by DA Pam 738-750 as contained in Maintenance Manage-ment Update.
b. Reporting of Item and Packaging Discrepancies.
Fill out and forward SF 364 (Report of Discrepancy [ROD]) as prescribed in AR 735-11–2.
c. Transportation Discrepancy Report (TDR) SF 361. Fill out and forward SF 361 as prescribed in
AR 55-38.
1-5 DESTRUCTION OF ARMY ELECTRONIC
MATERIEL
Destruction of Army electronics materiel to prevent enemy use shall be in accordance with TM 750-244-2.
1-2
1-6 REPORTING EQUIPMENT IMPROVEMENT
RECOMMENDATIONS (EIR’s)
If your Test Set needs improvement, let us know. Send us an EIR. You, the user, are the only one who can tell us what you don’t like about your equipment. Let us know why you don’t like the design or performance. Put it on an SF 368 (Product Quality Deficiency Report). Mail it to:
Commander US Army Communications–Electronics Command
ATTN: AMSEL–ED-PH
Fort Monmouth, New Jersey 07703–5007.
We’ll send you a reply.
1-7 WARRANTY
The TS-4348/UV Test Set, Electronic Systems is not under warranty. Estimated reliability is 63,000 operational hours before failure. Due to high reliability and no failures antici-pated in the first two years of operation, no warranty is re-quired. The unit level warranty control burden is elimi-nated.
Section II. EQUIPMENT DESCRIPTION
1-8 DESCRIPTION
The Test Set, Electronic Systems, TS-4348/UV includes the items in the following list and shown in Figure 1–1.
1. Case, Elec 5. Adapter, Viewer
2. Operator’s Manual 6. Test Set, Unit Assy
3. Adapter, Resilient 7. Lens Paper
4. Adapter, Set Connector 8. Case, Optical Inst
1-3
Figure 1-1 Test Set, Electronic Systems (TS-4348/UV)(Sheet 1 of 2)
1-4
Figure 1-1 Test Set, Electronic Systems (TS-4348/UV)(Sheet 2 of 2)
1-5
1-8.1 Case, E1ec
The canvas case (Figure 1–1, Item 1) is provided for trans-portation and protection of the Test Set, Unit Assy, all three adapters (Items 3,4, and 5), battery, Operator’s Manual, and lens paper. The case has two slide keepers for belt attach-ment.
1-8.2 Operator’s Manual The Operator’s Manual (Item 2) provides operation and in-stallation instructions for the Test Set.
1-8.3 Adapter, Resilient
The Adapter, Resilient (Item 3) is used to attach the Test Set, Unit Assy optics to the night vision goggles listed below:
AN/PVS-5A, 5B, and 5C AN/PVS-7A and 7B AN/AVS-6(V)1 and (V)2
1-8.4 Adapter, Set Connector
The Adapter, Set Connector (Item 4) is used to attach the Test Set, Unit Assy optics to the night vision devices listed below:
AN/TVS-5
AN/PVS-4
1-8.5 Adapter, Viewer
The Adapter, Viewer (Item 5) is used to attach the Test Set, Unit Assy optics to the night vision devices listed below:
AN/VVS-2(V)lA, (V)2A, (V)3, and (V)4
1-6
1-86 Test Set, Unit Assy
The Test Set, Unit Assy (Item 6) performs the GO/NO GO check of the night vision device attached to it.
1-8.7 Lens Paper
Lens Paper (Item 7) is provided and used to clean the Test Set, Unit Assy and Adapter, Viewer optical surfaces.
1-8.8 Case, Optical Inst
The Case, Optical Inst (Item 8) is used for storage and trans-portation of the Test Set, Unit Assy and and all of its acces-sories. Batteries may also be stored in the case.
1-9 CHARACTERISTICS
The Test Set is a small, lightweight, hand-held testing de-vice that can be readily used to evaluate the condition of the image intensifier and provide a GO/NO GO check of the night vision system. The Test Set can be used in all weather conditions and is easily carried. The following paragraphs provide information pertaining to mechanical and electrical characteristics of the Test Set.
1-9.1 Mechanical Characteristics
Refer to Table 1–1 for Test Set Mechanical Characteristics.
Table 1-1 Test Set Mechanical Characteristics
ITEM CHARACTERISTICS
Case, Optical Inst 11” x 15” x 5.5”
Case, Elec (canvas) 6” x 9” x 2.75”
Test Set, Unit Assy 400 grams (14.1 oz)
1-7
1-9.2 Electrical Characteristics Refer to Table 1–2 for Test Set Electrical Characteristics.
Batteries are not supplied with the Test Set and must be ob-tained separately.
Table 1-2 Test Set Electrical Characteristics
ITEM CHARACTERISTICS
Power Source Battery — 9.0 VDC max
Battery Requirements 1 ea Alkaline
BA-3090/U
Test Set Operating Temperature Range –32°C to +52°C
1-10 Model Differences
The most recently produced TS-4348/UV Test Sets, begin-ning in December 1992, are slightly different than the initial production Test Sets. A third LED is located on the control panel and, when illuminated, will indicate to the operator that the test set should be turned in to TMDE calibration support personnel for verification of correct light levels.
Also, a new instruction label is affixed to the outer case of the test set which duplicates the pass/fail criteria and target group and element numbers found within this manual.
1-8
CHAPTER 2
OPERATING INSTRUCTIONS
2-1
SECTION I
2-2
SECTION II
2-3 2-3.1 2-3.2 2-3.3 2-3.4 2-4
SECTION III
2-5 2-6 2-7 2-7.1 2-7.2 2-7.3 2–8
GENERAL . . . . . . . . . . . . . . . . . . . . 2-2
DESCRIPTION AND USE OF
OPERATOR’S CONTROLS AND
INDICATORS . . . . . . . . . . . . . . . . . 2–2
OPERATOR’S CONTROLS AND
INDICATORS . . . . . . . . . . . . . . . . . 2–2
PREVENTIVE MAINTENANCE
CHECKS AND SERVICES . . . . . . . 2-4
GENERAL . . . . . . . . . . . . . . . . . . . . 2-4
Before You Operate . . . . . . . . . . . . . 2–5 While You Operate . . . . . . . . . . . . . . 2–5 After You Operate . . . . . . . . . . . . . . . 2–5 If Your Equipment Fails cooperate . 2–5
ROUTINE CHECKS . . . . . . . . . . . . 2-5
OPERATION UNDER USUAL
CONDITIONS . . . . . . . . . . . . . . . . . 2-6
UNPACKING . . . . . . . . . . . . . . . . . . 2-6
BATTERY INSTALLATION . . . . . . 2-6
ADAPTER INSTALLATION . . . . . 2–7
Adapter, Resilient . . . . . . . . . . . . . . . 2-9 Adapter, Set Connector . . . . . . . . . . 2–11 Adapter, Viewer . . . . . . . . . . . . . . . 2-l3
NIGHT VISION DEVICE
TESTING . . . . . . . . . . . . . . . . . . . . 2-15
2-1
2-8.1 Testing Night Vision Goggles . . . . . . 2–16 2-8.2 Testing Weapon Sights . . . . . . . . . . . 2–2 1 2-8.3 Testing Driver’s Viewers . . . . . . . . . . 2–23
2-1 GENERAL
This chapter contains the information necessary to prepare and use the Test Set. This includes unpacking, examination for damage, battery installation, adapter installation, and Test Set operation instructions.
Section I DESCRIPTION AND USE OF
OPERATOR’S CONTROLS
AND INDICATORS
2-2 OPERATOR’S CONTROLS AND INDICATORS
The operator’s controls and indicators required to operate the Test Set, Unit Assembly are described in Table 2–1. Re-fer to Figure 2–1 for location of controls and indicators.
Table 2-1 Operator’s Controls and Indicators
ITEM CONTROLS FUNCTIONS
(Fig 2-1) AND
INDICATORS
1. Switch II/III Selects Night Vision De-vice to be tested and turns on the Test Set.
Position II Position utilized to test:
AN/PVS-5A, 5B, 5C
AN/PVS-7A and 7B
AN/VVS-2(V) 1A, 2A, 3,
and 4
AN/TVS-5
AN/PVS4
2-2
Table 2-1 Operator’s Controls and Indicators (Con't)
ITEM CONTROLS FUNCTIONS
(Fig 2-1) AND
INDICATORS
Position III Position utilized to test:
2. High/Low Switch
High
Low
3. Low Battery
4. Check Calibration
AN/AVS-6
Selects the light level to be used.
Selects test pattern (target) light level at about equiva-lent of bright moonlight.
This allows testing of the high light performance of the image intensifier.
Sets test pattern (target) light level at about equiva-lent of a cloudy, starlit night. This level tests the low light performance of the image intensifier.
Lights to indicate a low battery condition.
Lights to indicate the Test Set must be checked for correct calibration.
5. Power On Indicates if Test Set is on.
2-3
Figure 2-1 Operator’s Controls and Indicators
Section II PREVENTIVE MAINTENANCE
CHECKS AND SERVICES
2-3 GENERAL
Preventive maintenance checks and services (PMCS) for this equipment are limited to routine checks. Routine checks are not done on schedule (daily, Monthly, etc.) but are done as required. This means that the operator must be alert to the condition of the equipment and what is happen-ing to it. The operator must correct any small problems when they happen, rather than waiting for a scheduled maintenance time.
2-4
2-3.1 Before You Operate
Always keep in mind the CAUTIONS and WARNINGS.
Perform your before (B) PMCS prior to the equipment leav-ing its containment area or before its intended use.
2-3.2 While You Operate
Always keep in mind the CAUTIONS and WARNINGS.
Perform your during (D) PMCS when the equipment is be-ing used in its intended mission.
2-3.3 After You Operate
Be sure to perform your after (A) PMCS after the equip-ment has been taken out of its mission mode or returned to its containment area.
2-3.4 If Your Equipment Fails To Operate Refer to Table 3-1 for troubleshooting procedures.
2-4 ROUTINE CHECKS
Use the list below to establish routine checks of the Test Set.
a. Clean-Equipment should be free from dust and grease.
b. Stowing – When not in use, stow the equipment properly.
c. Battery – Remove the battery for storage/ stowage.
2-5
Section III OPERATION UNDER USUAL
CONDITIONS
2-5 UNPACKING
The following steps, a through d, must be performed when unpacking the Test Set for use.
a. Release the two latches securing the top of the shipping and storage case and open top.
b. Check contents of Case, Optical Inst for completeness. (See Fig. 1–1 ).
c. Remove Case, Elec from the Case, Optical Inst.
Open Case, Elec, check contents for complete-ness (refer to Fig. 1–1, Sheet 2 of 2), and remove Test Set, Unit Assembly.
d. Inspect Test Set, Unit Assy for obvious evidence of damage. Remove the lens cap and examine window and clean per paragraph 3–3, if necessary.
2-6 BATTERY INSTALLATION
The Test Set uses the BA–3090/U as its power source. A battery is not supplied with the Test Set and must be ob-tained separately. Install the 9 volt battery as follows (refer to Fig. 2–2 for illustration):
a. Remove the battery cover by unscrewing the captive screws.
2-6
b. Observe polarity, as indicated by the battery connection pigtail and connect the battery to the connector.
c. Insert the battery into the battery compartment.
CAUTION
When removing the battery cover to service the battery, use caution not to damage or lose the gasket.
d. Close the battery compartment cover and tighten the captive screws to ensure a watertight seal.
2-7 ADAPTER INSTALLATION
The Test Set, Unit Assy comes with the standard adapter in-stalled (Adapter, Resilient). The resilient adapter is used for test night vision goggles. This adapter is threaded into the body of the Test Set Unit Assy and is replaceable with other adapters to allow for testing of a variety of night vision devices (Fig. 2-3). Installation instructions for each of the available adapters, including the resilient adapter, are de-scribed in the following paragraphs.
CAUTION
The Test Set, Unit Assembly is a delicate instrument. Exer-cise care not to overtighten or strip the adapter threads or Test Set, Unit Assembly body threads when performing in-stallation or removal of any adapter.
2-7
Figure 2-2. Battery Replacement
2-8
Figure 2-3 Test Set, Unit Assy and Adapters
2-7.1 Adapter, Resilient
Adapter, Resilient (Fig. 2–3, Item 1) is the standard adapter on the Test Set, Unit Assy. It is used to test the night vision goggles listed below. To install the adapter, refer to Fig. 2-4 and use the following procedure.
a.
b.
Hold the Test Set, Unit Assy firmly in one hand.
Inspect the threads of the Adapter, Resilient and the Test Set, Unit Assy for damage.
2-9 c.
d.
Match the threaded end of the adapter to the threaded opening (twist adapter clockwise) of the Test Set, Unit Assy.
Screw the adapter into the threaded opening being careful not to cross–thread the adapter.
The Adapter, Resilient is used to test:
AN/PVS-5A, 5B, 5C
AN/PVS-7A and 7B AN/AVS-6(V) 1 and (V)2
To test the above equipment, refer to para. 2–8 and 2–8. 1.
Figure 2-4 Mounting the Adapter, Resilient
2-10
2-7.2 Adapter, Set Connector
Adapter, Set Connector (Fig. 2–3, Item 2) is a large adapter used to test the various weapon sights that have night vision capabilities. The night vision devices that can be tested with this adapter are listed below. To install the adapter, re-fer to Fig. 2–5 and use the following procedure.
NOTE
It is best to place the Adapter, Set Connector face down on a flat surface (or the palm of your hand) and attach the Test Set, Unit Assy to it.
a.
b.
c.
d.
Inspect the threads of the Adapter, Set Con– nector and the Test Set, Unit Assy for damage.
Place the adapter face down (threaded portion
up) on a flat surface.
Match up the threaded end of the adapter to the threaded opening of the Test Set, Unit Assy.
Screw the Test Set, Unit Assy (rotate the set around the adapter) clockwise onto the Adapter Set Connector, being careful not to overtighten or cross thread the adapter.
The Adapter, Set Connector is used to test:
AN/PVS-4
AN/TVS-5
To test the AN/PVS-4 or AN/TVS-5, refer to para. 2–8 and 2-8.2
2-11
Figure 2-5 Mounting the Adapter, Set Connector 2-12
2-7.3 Adapter, Viewer
Adapter, Viewer (Fig. 2–3, Item 3) is a large adapter used to test driver’s viewer type night vision devices. The night vision devices that can be tested with this adapter are listed below. To install the adapter, refer to Fig. 2-6 and use the following procedure.
NOTE
It is best to place the Adapter, Viewer face down on a flat surface (or the palm of your hand) and attach the Test Set, Unit Assy to it.
a.
b.
c.
d.
Inspect the threads of the Adapter, Viewer and the Test Set, Unit Assy for damage.
Place the adapter face down (threaded portion
up) on a flat surface.
Match up the threaded end of the adapter to the threaded opening of the Test Set, Unit Assy.
Screw the Test Set, Unit Assy (rotate the set clockwise around the adapter threads) onto the Adapter, Viewer being careful not to overtighten or cross-thread the adapter.
The Adapter, Viewer is used to test:
AN/VVS-2(V) 1A, 2A, 3, and 4
To test the above equipment, refer to para. 2–8 and 2–8.3.
2-13
Figure 2-6 Mounting the Adapter, Viewer
2-14
2-8 NIGHT VISION DEVICE TESTING
The NVD test results are likely to vary from operator to op-erator. Operators should have experience with the Test Set.
NOTE
The Test Set is used only to check resolution performance of the center portion of each image intensifier. Normal viewing during operation continues to be the procedure to evaluate each tube for cosmetic defects. Since the Test Set does not illuminate the entire field of view, outer circumfer-ence defects such as shading must be detected during nor-mal viewing. NVD’S failing the test should be turned into higher maintenance.
For correct operation of the Test Set you must select the cor-rect adapter and Switch II/III setting. Table 2-2 below pro-vides a quick reference for selecting the correct adapter and Switch II/III setting.
Table 2-2 Test Set, Set Up
NIGHT VISION ADAPTER SWITCH
DEVICE NAME II/III
SETTING
AVS-6(V) 1 & 2 Adapter, Resilient III PVS-4 Adapter, Set
Connector II PVS–5A, 5B, 5C Adapter, Resilient II PVS–7A & 7B Adapter, Resilient II TVS-5 Adapter, Set
Connector II VVS–2(V)1A, Adapter, Viewer II 2A, 3, and 4
2-15
2-8.1 Testing Night Vision Goggles
Use the following procedures to test Night Vision Goggles (NVG). If you are testing a two tube system, leave one ob-jective cap in place when testing the NVG. A goggle system will fail the test if one or both of the tubes exhibits a failure of the test.
NOTE
Testing must be performed in a darkened area such as a tent, room, shelter, or an outside area at night where there is no external lighting. Your eyes must be dark–adapted in order to perform this test. It takes approximately 10 minutes to become properly dark-adapted for low light resolution evaluation. However, if you have just been exposed to bright sunlight, dark adaptation will take longer.
AN/AVS-6 Light Interference Filters shall be installed when testing is performed. However, installation of AN/ PVS-7 Light Interference Filters is not necessary for this test.
Expect cosmetic blemishes such as chicken wire, black spots, and fixed-pattern noise to stand out while viewing through the Test Set when it is on the high light level. This is acceptable.
Review the following test procedures before entering the darkened area.
2-16
a. Attach the Test Set, Unit Assy with the adapter to the NVG as shown in Fig. 2–7.
b. Select High Light test by setting the High/Low Switch to High.
c. Turn on the Test Set, Unit Assy by selecting the Switch II/III position (Table 2–2) for the type of NVG being tested. Check to see if the green PWR ON light is lit.
d. Look through the NVG and view the projected test pattern being supplied by the Test Set, Unit Assy (Figure 2–8).
e. Adjust the eyepiece focus and the objective lens focus to obtain the sharpest view of the pattern.
2-17
Figure 2-7 Testing Night Vision Goggles
2-18
f. Determine the group number and element number of the smallest pattern resolvable.
Refer to Table 2–3 to determine if the goggles passed the High Light test.
NOTE
To successfully resolve a pattern which finds the tube ac-ceptable for use, you must be able to distinguish that the three vertical bars are in the vertical position and the three horizontal bars are in fact horizontal. This procedure re-quires you to scan left and right (for the vertical bars) and up and down (for the horizontal bars) as you observe the pattern.
g. Select Low Light test by setting the High/Low Switch to Low. Adjust eyepiece and objective focus, if necessary.
h. Determine the group number and element number of the smallest pattern resolvable. Refer to Table 2–3 to determine if the goggles passed the Low Light test.
i. For the AN/PVS-5 and AN/AVS-6 series NVG’S, switch the High/Low Switch to High and repeat steps d through h for the other tube.
j. If the goggles do not pass the test, refer to higher level of maintenance.
2-19
Figure 2-8 Test Set Test Pattern 2-20
Table 2-3 Test Results
NVD SWITCH PASS/FAIL
TYPE II/III CRITERIA
POSITION (Group/Element)
High Low Light Light
AVS-6(V)1
& (V)2 III 3/5 2/2
PVS-5A,
5B & 5C II 3/3 2/1
PVS-7A
& 7B II 3/5 2/2
PVS-4 II 4/4 N/A
TVS–5 II 4/6 N/A
VVS–2
(V)lA, 2A, 3.&4 II 3/4 N/A
N/A = Low Light test not applicable for these NVD’S
2-8.2 Testing Weapon Sights
Use the following procedures to test night vision Weapon Sights (AN/PVS-4 and AN/TVS-5).
2-21
NOTE
Test should be performed in a dark location. Allow time for dark adaptation to occur prior to conducting the test.
a. Attach the Test Set, Unit Assy with the adapter to the NVD as shown in Fig. 2–9.
NOTE
Due to the size of most of these NVD’S, it is recommended that the weapon sight be mounted or supported.
b. Select High Light test by setting the High/Low Switch to High.
c. Turn on the Test Set, Unit Assy by setting the Switch II/III position (Table 2–2) to II. Check that the Test Set, Unit Assy is operating by checking the green PWR ON light.
d. Turn the NVD on to maximum brightness. Look through the NVD and view the projected test pattern supplied by the Test Set, Unit Assy (Fig. 2-8). If necessary, rotate the NVD in the adapter until the test pattern is centered within the lighted area.
e. Adjust the eyepiece focus and the objective lens focus to obtain the sharpest view of the pattern.
f. Determine the group number and element num– ber of the smallest pattern resolvable. Refer to Table 2–3 to determine if the sight passed the High Light level test.
2-22
To successfully resolve a pattern which finds the tube ac-ceptable for use, you must be able to distinguish that the three vertical bars are in a vertical position and that the three horizontal bars are in fact horizontal. This procedure re-quires you to scan left and right (for the vertical bars) and up and down (for the horizontal bars) as you observe the pattern.
g. If the weapon sight does not pass the test, refer it to a higher level of maintenance.
2-8.3 Testing Driver’s Viewers
Use the following procedures to test Night Vision Driver’s Viewers.
NOTE
Testing should be performed in a dark location. Allow time for dark adaptation to occur prior to conducting the test.
NOTE
The Test Set is to be used for the AN/VVS-2 resolution check only. It is not designed for performing the 50-foot focus adjustment. Only Direct Support facilities are autho-rized to adjust viewer focus.
a. Attach the Test Set, Unit Assy with the adapter to the NVD as shown in Fig. 2–10.
NOTE
Due to the size of these NVD’S, it is recommended that the viewer be mounted or supported.
2-23
Figure 2-9 Testing Weapon Sights
2-24
Figure 2-10 Testing Driver's Viewers (Sheet 1 of 3)
2-25
(Sheet 2 of 3)
2-26
(Sheet 3 of 3)
2-27 b.
c.
d.
e.
Select High Light test by setting the High/Low Switch to High.
Turn on the Test Set, Unit Assy by setting the Switch II/III position (Table 2–2) to II. Check that the Test Set, Unit Assy is operating by checking the green PWR ON light.
Turn on the NVD to its maximum brightness.
Look through the NVD and view the projected test pattern being supplied by the Test Set, Unit Assy (Fig. 2–8).
Determine the group number and element number of the smallest pattern resolvable. Refer to Table 2–3 to determine if the viewer passed the High Light level test.
NOTE
To successfully resolve a pattern which finds the tube ac-ceptable for use, you must be able to distinguish that the three vertical bars are in a vertical position and the three horizontal bars are in fact horizontal. This procedure re-quires you to scan left and right (for the vertical bars) and up and down (for the horizontal bars) as you observe the pattern.
f. If the viewer does not pass the test, refer to a higher level of maintenance.
2-28
CHAPTER 3
OPERATOR MAINTENANCE
SECTION I
3-1
SECTION II
3-2
SECTION III
3-3 3-4 3-5
3-6
LUBRICATION . . . . . . . . . . . . . . . . 3-1
LUBRICATION . . . . . . . . . . . . . . . . 3-1
TROUBLESHOOTING . . . . . . . . . . 3–1
TROUBLESHOOTING TABLE . . . 3–1
MAINTENANCE . . . . . . . . . . . . . . . 3–2
OPTICS CLEANING . . . . . . . . . . . . 3-2
ADAPTER, VIEWER REPAIR . . . . 3–3
BATTERY COMPARTMENT
GASKET REPLACEMENT . . . . . . 3-4
LENS CAP REPLACEMENT . . . . . 3-6
Section I LUBRICATION
3-1 LUBRICATION
There are no lubrication requirements for the Test Set.
Section II TROUBLESHOOTING
3-2 TROUBLESHOOTING TABLE
Table 3–1 lists the common malfunctions which you may find during the operation or maintenance of the Test Set.
You should perform the test/inspections and corrective ac-tions in the order listed. This manual cannot list all mal-functions that may occur, or all test or inspections and cor-rective actions.
3-1
Table 3-1 Troubleshooting
MALFUNCTION TEST OR CORRECTIVE
INSPECTION ACTION
Battery Low Low Battery Light lit per para. 2-6
Test Set Requires CHK CAL Notify supporting Calibration Check Light lit US Army Test
Support Group
(USATSG)
If a malfunction is not listed or is not corrected by listed cor-rective actions, notify your supervisor.
Section III MAINTENANCE
3-3 OPTICS CLEANING
Using the lens paper listed in the Appendix E, follow the procedures below.
a.
b.
3-2
Remove the Adapter, Resilient from the Test Set, Unit Assy by turning the adapter counter-clockwise.
Remove loose particles of dirt. Wipe the optical surface with a clean lens paper, dampening with clean water if necessary. With a circular motion and light pressure, wipe surface until the optical window is clean and thoroughly dry.
Replace the Adapter, Resilient per para. 2-7.1.c .
3-4 ADAPTER, VIEWER REPAIR
If the strap(s) on the Adapter, Viewer become unusable, they may be replaced following the procedure listed below (refer to Fig. 3-1).
a. Remove the old strap by pulling the strap out of the strap eyes on the Adapter, Viewer body.
b. Install the new strap.
Figure 3-1 Adapter, Viewer Repair 3 - 3
3-5 BATTERY COMPARTMENT GASKET
REPLACEMENT
If the battery compartment cover gasket becomes damaged.
it maybe replaced by following the procedure below. The replacement procedure is illustrated by Fig. 3–2.
a. Open the battery compartment by unscrewing the captive screws.
b. Remove battery by disconnecting the battery pigtail.
c. Move the battery compartment cover out of the way.
d. Remove the old gasket and any leftover gasket remnants. Install the new battery compartment gasket.
e. Replace the battery. Replace the battery com-partment cover and tighten the captive screws to prevent moisture from entering the battery compartment.
3 - 4
Figure 3-2 Gasket Replacement Procedure 3-5
3-6 LENS CAP REPLACEMENT
If the Lens Cap becomes damaged, it may be replaced by following the procedure. The replacement procedure is il-lustrated by Fig. 3–3.
a.
b.
c.
d.
Remove the Adapter, Resilient by turning the.
adapter counterclockwise.
Remove the old Lens Cap.
Slip the new Lens Cap opening over the threaded end of the Adapter, Resilient.
Install the Adapter, Resilient per para. 2–7. 1.
Figure 3-3 Lens Cap Replacement Procedure
3 - 6
APPENDIX A
REFERENCES
A-1 SCOPE
This appendix lists all the forms and publications referred to in this manual.
A-2 REFERENCE LIST
DA PAM 738-750 The Army Maintenance Management System
(TAMMS)
DA FORM 2028 Recommended Changes to Equipment Technical Publications
SF 368 Quality Deficiency Report
A-1/(A-2 blank)
APPENDIX B
MAINTENANCE ALLOCATION CHART
Section I INTRODUCTION
B-1 GENERAL
a. This section provides a general explanation of all maintenance and repair functions authorized at various maintenance categories.
b. The Maintenance Allocation Chart (MAC) in Section II designates overall authority and responsibility for the performance of maintenance functions on the identi-fied end item or component. The application of the mainte-nance functions on the identified end item or component will be consistent with the capacities and capabilities of the designated maintenance categories.
c. Section III lists the tools and test equipment (both special tools and common tool sets) required for each maintenance function as referenced from Section II.
d. Section IV contains supplemental instructions and explanatory notes for a particular maintenance func-tion.
B-2 MAINTENANCE FUNCTIONS
Maintenance functions will be limited to and defined as fol-lows:
B-1
a. Inspect – To determine the serviceability of an item by comparing its physical, mechanical and/or electri-cal characteristics with established standards throughout examination.
b. Test – To verify serviceability by measuring the mechanical, pneumatic, hydraulic, or electrical characteris-tics of an item and comparing those characteristics with pre-scribed standards.
c. Service – Operations required periodically to keep an item in proper operating condition, i.e. to clean, pre-serve, drain, paint, or replenish fuel/lubricants/hydraulic fluids or compressed air supplies.
d. Install – The act of replacing, seating, or fixing into position an item, part, module (component or assem-bly) in a manner to allow the proper functioning of the equipment or system.
e. Replace – The act of substituting a serviceable like type part, subassembly, module (component or assem-bly) for an unserviceable counterpart.
f. Repair – The application of maintenance ser-vices (inspect, test, service, adjust, align, calibrate, replace) or other maintenance action (welding, grinding, riveting, straightening, facing, remachining, or resurfacing) to re-store serviceability to an item by correcting specific dam-age, fault, malfunction, or failure in a part, subassembly, module (component or assembly), end item, or system.
B-2
B-3 EXPLANATION OF COLUMNS IN THE MAC,
SECTION II
a. Column (1), Group Number – Column 1 lists group numbers, the purpose of which is to identify compo-nents, assemblies, subassemblies, and modules with the next higher assembly.
b. Column (2), Component Assembly – Column 2 contains the noun names of components, assemblies, and modules for which maintenance is authorized.
c. Column(3), Maintenance Function –Column 3 lists the functions to be performed on the item listed in Column 2. When items are listed without maintenance functions, it is solely for the purpose of having the group numbers in the MAC and RPSTL coincide.
d. Column (4), Maintenance Category –Column 4 specifies, by the listing of a “work time” figure in the ap-propriate subcolumn(s), the category of maintenance au-thorized to perform the function listed in Column 3. This figure repesents the active time required to perform that maintenance function at the indicated category of mainte-nance. If the number or complexity of the tasks within the listed maintenance function varies at different maintenance categories, appropriate “work time” figures represents the average time required to restore art item (assembly, subas-sembly, component, module, end item, or system) to a ser-viceable condition under typical field operating conditions.
B-3
This time includes preparation time, troubleshooting time and quality assurance/quality control time, in addition to the time required to perform the specific task identified for the maintenance functions authorized in the MAC. Subco-lumns of Column 4 areas follows:
C – Operator/Crew O – Organization Maintenance F – Direct Support Maintenance H – General Support Maintenance D – Depot Maintenance
e. Column (5), Tools and Equipment – Column 5 specifies, by code, those common tool sets (not individual tools) and special tools, test and support equipment re-quired to perform the designated function.
f. Column (6), Remarks – Column 6 contains an alphabetic code which leads to the remark in Section IV, Re-marks, which is pertinent to the item opposite the particular code.
B-4 EXPLANATION OF COLUMNS IN TOOL AND
TEST EQUIPMENT REQUIREMENTS,
SECTION III
a. Tools or Test Equipment Reference Code – The numbers in this column coincide with the numbers used .
in the tools and equipment column of the MAC. The num-bers indicate the applicable tool or test equipment for the maintenance functions.
B - 4
b. Maintenance Category– The codes in this col-umn indicate the maintenance category allocated the tool or test equipment.
c. Nomenclature – This column lists the noun name and nomenclature of the tools and test equipment re-quired to perform the maintenance functions.
d. National/NATO Stock Number (NSN) – This column lists the National/NATO stock number of the spe-cific tool or test equipment.
e. Tool Number – This column lists the manufac-turer’s part number of the tool followed by the Contractor and Government Entity Code (CAGEC).
B-5 EXPLANATION OF COLUMNS IN REMARKS,
SECTION IV
a. Reference Code - This code refers to the appro-priate item in Section II, Column 6.
b. Remarks – This column provides the required explanatory information necessary to clarify items appear-ing in Section II.
B - 5
S ection II
G roup N um ber 00
G roup N um ber 01
G roup N um ber 02
B -6 ection III
-7 ection IV
-8
APPENDIX C
COMPONENTS OF END ITEM
AND BASIC ISSUE ITEMS
Section I INTRODUCTION
C-1 SCOPE
This appendix lists components of end item and basic issue items for the Test Set to help you inventory items required for safe and efficient operation.
C-2 GENERAL
The Components of End Item and Basic Issue Items Lists are divided into the following sections:
a. Section II Components of End Item – This listing is for information purposes only, and is not authority to requisition replacements. These items are part of the end item, but are removed and separately packaged for trans-portation or shipment. As part of the end item, these items must be with the end item whenever it is issued or trans-ferred between property accounts. Illustrations are fur-nished to assist you in identifying the items.
b. Section III Basic Issue Items – These are the minimum essential items required to place the Test Set in operation, to operate it, and to perform emergency repairs.
Although shipped separately packaged, Basic Issue Items (BII) must be with the Test Set during operation and when-ever it is transferred between property accounts. The illus-trations will assist you with hard-to-identify items. This manual is your authority to request/requisition replacement BII, based on TOE/MTOE authorization of end item.
C-1
C-3 EXPLANATION OF COLUMNS
The following provides an explanation of columns found in the tabular listing.
a. Column (1), Illustration Number – This col-umn indicates the number of the illustration in which the item is shown.
b. Column (2), National Stock Number – This column indicates the National Stock Number assigned to the item and will be used for requisitioning purposes.
c. Column (3), Description – This column indi-cates the Federal item name and, if required, a minimum de-scription to identify and locate the item. The last line for each item indicates the Contractor and Government Entity Code (CAGEC) (in parenthesis) followed by the part num-ber.
d. Column (4), Unit of Measure– This column in-dicates the measure used in performing the actual opera-tion/maintenance function. This measure is exposed by a two character alphabetical abbreviation (e.g., ea, in, and ft).
e. Column (5), Quantity Required – This column indicates the quantity of the item authorized to be used with/ on the equipment.
C-2
F igure C
-1
C -3
-1
C-4
SECTION II COMPONENTS OF END ITEM
(1) (2) (3) (4) (5)
ILLUSTRATION NATIONAL STOCK DESCRIPTION USABLE U/M QTY
NUMBER NUMBER CAGEC AND PART NUMBER ON RQRD
CODE
1 TEST SET, UNIT ASSY EA 1
(80063) A3139850
2 5340-01-327-2704 ADAPTER, RESILIENT EA 1
(80063) A3139787
3 5935-01-327-2705 ADAPATER, SET CONNECTOR EA 1
(80063) A3139778
4 5855-01-327-2681 ADAPTER, VIEWER EA 1
(80063) A3139777
5 6650-01-327-2677 CAP, LENS EA 1
(80063) A3139804
6 1240-01-327-2702 CASE, OPTICAL INST EA 1
(80063) A3139779
7 6625-01-328-4504 CASE, ELEC EA 1
(80063) A3139780
C-5
-2
T M
11-5855-299-12& P
C -6
SECTION III BASIC ISSUE ITEMS
ILLUSTRATION NATIONAL STOCK DESCRIPTION USABLE U/M QTY
NUMBER NUMBER CAGEC AND PART NUMBER ON RQRD
CODE
1 OPERATOR'S MANUAL EA 1
C-7/(C-8 BLANK)
APPENDIX D
ADDITIONAL AUTHORIZATION LIST
Section I INTRODUCTION
D-1 SCOPE
This appendix lists additional items you are authorized for the support of the Test Set.
D-2 GENERAL
This list identifies items that do not have to accompany the Test Set and that do not have to be turned in with it. These items are all authorized to you by CTA, MTOE, TDA, or
JTA.
D-3 EXPLANATION OF LISTING
National Stock Numbers, descriptions, and quantities are provided to help you identify and request the additional items you require to support this equipment. The items are listed in alphabetical sequence by item name under the type document (i.e., CTA, MTOE, TDA, or JTA) which autho-rizes the item(s) to you.
D-1
SECTION II ADDITIONAL AUTHORIZATION LIST
(1) (2) (3) (4)
NATIONAL STOCK DESCRIPTION USABLE U/M QTY
NUMBER CAGEC AND PART NUMBER ON RQRD
CODE
6135-01-063-1978 BATTERY,9 VOLT EA 1
BA-3090/U
D-2
APPENDIX E
EXPENDABLE/DURABLE SUPPLIES
AND MATERIALS
Section I INTRODUCTION
E-1 SCOPE
This appendix lists expendable supplies and materials you will need to operate and maintain the Test Set. This listing is for informational purposes only and is not authority to requisition the listed items. These items are authorized to you by CTA 50-970, Expendable/Durable Items (except Medical, Class V, Repair Parts, and Heraldic Items), orCTA 8-100, Army Medical Department Expendable/Durable Items.
E-2 EXPLANATION OF COLUMNS
a. Column(1), Item Number– This number is as-signed to the entry in the listing and is referenced in the nar-rative instructions to identify the material (e.g., ”Use clean-ing compound, item 5, App. E”).
b. Column (2), Level – This column identifies the loewst level of maintenance that requires the listed item.
C – Operator/Crew
c. Column (3), National Stock Number – This is the National Stock Number assigned to the item. Use this number to requisition the item.
E-1
d. Column (4), Description – This column indi-cates the Federal item name and, if required, a description to identify the item. The last line for each item indicates the Commercial and Government Entity Code (CAGEC) in pa-ranthesis followed by the part number.
e. Column (5), Unit of Measure - This column in-dicates the measure used in performing the actual mainte-nance function. This measure is expressed by a two-char-acter alphabetical abbreviation (e.g., ea, in, pr). If the unit of measure differs from the unit of issue, requisition the lowest unit of issue that will satisfy your requirements.
E-2
SECTION II EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST
ITEM LEVEL NATIONAL STOCK DESCRIPTION U/M
NUMBER NUMBER
1 C 6640-00-597-6745 PAPER, LENS PK
E-3/(E-4 BLANK)
APPENDIX F
REPAIR PARTS AND
SPECIAL TOOLS LIST
Section I INTRODUCTION
F-1 SCOPE
This appendix lists and authorizes spares and repair parts;
special tools; special test, measurement, and diagnostic equipment (TMDE); and other special support equipment required for performance of unit maintenance of the TS-4348/UV. It authorizes the requisitioning, issue, and disposition of spares, repair parts, and special tools as indi-cated by the source, maintenance, and recoverability (SMR) codes.
F-2 GENERAL
This Repair Parts and Special Tools List (RPSTL) is di-vided into the following sections:
a. Section II Repair Parts List – A list of spares and repair parts authorized by this RPSTL for use in the per-formance of maintenance. The list also includes parts which must be removed for replacement of the authorized parts. Parts lists are composed of functional groups in as-cending numeric sequence, with the parts in each group listed in ascending item number sequence. Figure numbers are listed directly beneath the group header. Items listed are shown on the associated illustration.
b. Section III Special Tools List – Not applica-ble.
F-1
c. Section IV Cross-Reference Indexes – A list, in National item identification number (NIIN) sequence, of all National Stock Numbered (NSN) items appearing in the listing, followed by a list in alphanumeric sequence of all part numbers appearing in the listings. NSN’s and part numbers are cross–referenced to each illustration figure and item number appearance. The figure number and item number index lists figure and item numbers in numeric se-quence and cross-references NSN’s, CAGEC and part numbers.
F-3 EXPLANATION OF COLUMNS (Section II and III)
a. Column(1), Item Number– This column indi-cates the number used to identify items called out in the il-lustration.
b. Column (2), SMR Code – The source, mainte-nance, and recoverability (SMR) code is a five-position code containing supply/requisitioning information, main-tenance category authorization criteria, and disposition in-structions, as shown in the following breakout:
F-2
Complete Repair – Maintenance capacity, capability, and authority to perform all corrective maintenance tasks of the “repair” function in a use/user environment in order to re-store serviceability to a failed item.
(1) Source Code - The source code tells you how to get an item needed for maintenance, repair, or over-haul of an end item. Explanation of source codes as follows:
Code Explanation
PA Stocked items; use the applicable PB NSN to request/requisition items PC with these source codes. They are PD authorized to the category indicated PE by the code entered in the third PF position of the SMR code.
PG
NOTE
Items that are PC coded are subject to deterioration.
KD Items with these codes are not to be KF requested/requisitioned separately.
KB They are part of a kit which is auth– orized to the maintenance category indicated in the third position of the SMR code. The complete kit must be requisitioned and applied.
F-3
Code Explanation
MO- Made at Org/AVUM category
MF– Made at
DS/AVIM
category
MH– Made at GS category
ML– Made at Specialized Repair Activity
(SRA)
MD- Made at Depot
AO- Assembled by Org/AVUM category
AF– Assembled by
DS/AVIM
category
AH– Assembled by GS category
AL– Assembled by
SRA
AD- Assembled by Depot
Items…
This is the start of the file's text. The full file is on GovTribe.