This document contains a federal solicitation for construction services and a project description. The U.S. Army Corps of Engineers is seeking bids for Project No. 390321 to construct a 6,480 square foot pre-engineered metal building addition to an existing vehicle maintenance facility at Camp James A. Garfield Joint Military Training Center in Ravenna, Ohio. The addition will include two drive-through work bays and metal exterior walls and roof to match the existing building. The solicitation includes nine options in addition to the base scope of work. Bids are due by the date and time specified in block 13 of the solicitation. The award will be a firm fixed-price contract to the responsible bidder providing the most advantageous offer to the government based on price alone. Interested parties must register in the System for Award Management to be eligible to bid.

View the file

Other files

Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CJAG JMTC UTES TWO BAY ADDITION

OHIO ARMY NATIONAL GUARD

PN# 390321

Copyright 2015 by The American Institute of Architects (AIA)

Exclusively published and distributed by Deltek, Inc. for the AIA

SECTION 224233 - WASH FOUNTAINS

Revise this Section by deleting and inserting text to meet Project-specific requirements.

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Semicircular wash fountains.

1.2 ACTION SUBMITTALS

A. Product Data: For each type of product.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for wash fountains.

2. Include rated capacities, operating characteristics, electrical characteristics, and furnished specialties and accessories.

Retain "Shop Drawings" Paragraph below if fixtures or equipment includes wiring.

B. Shop Drawings: For each type of wash fountain.

1. Include plans, elevations, sections, and mounting details.

2. Include details of equipment assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location and size of each field connection.

3. Include diagrams for power, signal, and control wiring.

Retain subparagraph below when units with painted finish are required.

4. Color samples.

1.3 CLOSEOUT SUBMITTALS

A. Operation and Maintenance Data: For wash fountains and components to include in operation and maintenance manuals.

1.4 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1. Faucet Washers and O-Rings: Equal to 10 percent of quantity of each type and size installed.

2. Faucet Cartridges and O-Rings: Equal to 5 percent of quantity of each type and size installed.

PART 2 - PRODUCTS

Manufacturers and products listed in this Section are neither recommended nor endorsed by the AIA or Deltek. Before selecting manufacturers and products, verify availability, suitability for intended applications, and compliance with minimum performance requirements. For definitions of terms and requirements for Contractor's product selection, see Section 016000 "Product Requirements."

Product options commonly available from manufacturers are included in square brackets throughout the Section Text. Not every manufacturer listed can provide every option offered; verify availability with manufacturers. For definitions of terms and requirements for Contractor's product selection, see Section 016000 "Product Requirements."

Do not use the same plumbing fixture designation as is used for a plumbing fixture in another plumbing Section.

2.1 STAINLESS STEEL, SEMICIRCULAR WASH FOUNTAINS

Copy "Wash Fountains" Paragraph below and re-edit for each type of semicircular wash fountain required.

Insert letter and number combination to complete drawing designation. Use these designations on Drawings to identify each stainless steel, semicircular wash fountain.

A. Wash Fountains P-3: On-floor, stainless steel, semicircular receptor.

Retain "Basis-of-Design Product" Subparagraph and list of manufacturers below to require a specific product or a comparable product from manufacturers listed.

Retain Acorn Engineering Model 3422 option for semicircular wash fountain with two wash stations. Retain Model 3422ES for semicircular wash fountain with two wash stations and contoured base.

Retain Model 3423 for semicircular wash fountain with three wash stations. Retain Acorn Engineering Model 3423ES for semicircular wash fountain with three wash stations and contoured base.

Retain Model 3423ADA for ADA-compliant semicircular wash fountain with three wash stations. Retain Model 3423ADAES for ADA-compliant semicircular wash fountain with three wash stations and contoured base.

Retain Model 3424ADA for ADA-compliant semicircular wash fountain with four wash stations. Retain Model 3424ADAES for ADA-compliant semicircular wash fountain with four wash stations and contoured base.

Retain Model 3543 for on-floor semicircular wash fountain with three wash stations. Retain Model 3543DBS for on-floor semicircular wash fountain with three wash stations and deep bowl receptor.

Retain Model 3544 for on-floor semicircular wash fountain with four wash stations. Retain Model 3544DBS for non-ADA-compliant, on-floor semicircular wash fountain with four wash stations and deep bowl receptor.

1. Standard:

a. ASME A112.19.3/CSA B45.4.

Retain first subparagraph below for ADA Standards only when ADA-compliant fixtures are specified.

b. ADA Standards for Accessible Design.

2. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.

3. Receptor:

a. Standard: ASME A112.19.3/CSA B45.4 for stainless steel receptor.

b. Nominal Diameter: 38 inches.

In "Height to Rim" Subparagraph below, manufacturer's standard product is 34 inches (864 mm) above floor. Retain first option for "Junior" height when required for Project design and when ADA compliance is not required.

c. Height to Rim:34 inches above floor.

In "Depth" Subparagraph below, retain second option when fixture with deep bowl style receptor is specified.

d. Depth: Manufacturer's standard

In "Finish or Color" Subparagraph below, retain first option for standard finish, exposed stainless steel. Retain second option for units with painted exposed surfaces.

e. Finish or Color: No. 4 satin finish.

f. Drain: Dome strainer.

4. Spray Head:

a. Material: Stainless steel or integral part of receptor back.

b. Number of Wash Stations:Three.

c. Spray Nozzles: At each wash station, provide 0.5 gpm, vandal-resistant nozzle complying with ASME A112.18.1/CSA B125.1.

Verify option retained in "Control" Subparagraph below is available from listed manufacturers and for type of wash fountain required. Certain ADA-compliant models not available with push-button or foot controls.

d. Control: Individual foot-button actuation.

In "Valve and Supply" Subparagraph below, select first option for standard configuration. Select second option for optional configuration.

e. Valve and Supply: Hot and cold, ASSE 1070-compliant temperature and pressure balancing mixing valve, with integral checks and strainer.

Retain "Sensor" Subparagraph below if retaining "Individual, hardwired sensor" or "Individual, battery-powered sensor" option in "Control" Subparagraph above.

f. Sensor: ASME A112.18.1/CSA B125.1 and UL 1951.

Retain "Soap Dispensers" Subparagraph below when required for Project design. The soap dispenser options below do not comply with ADA requirements.

5. Soap Dispensers: Liquid or lotion soap pump.

In "Pedestal Material and Finish" Subparagraph below, black vinyl-clad galvanized steel is manufacturer's standard. Retain other option when required by Project design.

6. Pedestal Material and Finish: Stainless steel, No. 4 satin.

7. Supply Fittings:

a. Supply Piping: From wall.

8. Waste Fittings:

a. Standard: ASME A112.18.2/CSA B125.2.

b. Drain Piping: 1-1/2-inch OD tailpiece.

In "Trap and Drain Piping" Subparagraph below, retain first option when fixture water supply is through-wall configuration.

c. Trap and Drain Piping: NPS 2.

d. Vent Piping: Off-drain.

Retain "Shroud" Subparagraph below if required to conceal vertical supply and vent piping.

9. Shroud: Stainless steel of size to cover supply and vent piping.

Retain "Paper Towel Dispenser" Subparagraph below if required by Project design.

10. Paper Towel Dispenser: C-Fold or Multi-Fold.

In "Accessories" Subparagraph below, retain only subparagraphs needed to comply with Project design requirements.

11. Accessories:

a. Hose bibb left side.

b. Pipe column brace.

c. Column braced to backsplash.

d. Less backsplash.

12. Mounting:On-floor, with wall- and floor-mounting flanges on wash fountain base interior.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine roughing-in of water-supply, sanitary drainage, and vent piping systems to verify actual locations of piping connections before wash-fountain installation.

B. Examine walls and floors for suitable conditions where wash fountains will be installed.

C. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Install wash fountains level and plumb in accordance with roughing-in drawings.

B. Set freestanding wash fountains on floor.

C. Install off-floor carrier supports, affixed to building substrate, for wall-mounted wash fountains.

D. Install accessible, wall-mounted wash fountains at mounting height for handicapped/elderly in accordance with ICC A117.1.

E. Install water-supply piping with shutoff valve on each supply to each wash fountain to be connected to domestic-water distribution piping. Use ball or gate valve. Install valves in locations where they can be easily reached for operation. Valves are specified in Section 220523.12 "Ball Valves for Plumbing Piping" and Section 220523.15 "Gate Valves for Plumbing Piping."

F. Install trap and waste piping on each drain outlet of each wash fountain to be connected to sanitary drainage system.

G. Install wall flanges or escutcheons at piping wall penetrations in exposed, finished locations. Use deep-pattern escutcheons if required to conceal protruding fittings. Comply with escutcheon requirements specified in Section 220518 "Escutcheons for Plumbing Piping."

H. Seal joints between fixtures and walls using sanitary-type, one-part, mildew-resistant, silicone sealant. Match sealant color to fixture color. Comply with sealant requirements specified in Section 079200 "Joint Sealants."

3.3 CONNECTIONS

Coordinate piping installations and specialty arrangements with Drawings and with requirements specified in piping systems. If Drawings are explicit enough, these requirements may be reduced or omitted.

A. Connect wash fountains with water supplies, stops, and risers, and with traps, soil, waste, and vent piping. Use size fittings required to match fixtures.

B. Comply with requirements for water piping specified in Section 221116 "Domestic Water Piping."

C. Comply with requirements for soil and waste drainage piping and vent piping specified in Section 221316 "Sanitary Waste and Vent Piping."

D. Install protective-shielding pipe covers and enclosures on exposed supplies and waste piping of accessible wash fountains. Comply with requirements in Section 220719 "Plumbing Piping Insulation."

3.4 ADJUSTING

A. Operate and adjust wash fountains and controls. Replace damaged and malfunctioning wash fountains, fittings, and controls.

B. Adjust water pressure at faucets to produce proper flow.

C. Install fresh batteries in battery-powered, electronic-sensor mechanisms.

3.5 CLEANING AND PROTECTION

A. After installing wash fountains, inspect and repair damaged finishes.

B. Clean wash fountains, faucets, and other fittings with manufacturers' recommended cleaning methods and materials.

C. Provide protective covering for installed wash fountains and fittings.

D. Do not allow use of wash fountains for temporary facilities unless approved in writing by Owner.

END OF SECTION 224233