220519 meters and gages for plumbing piping.pdf

PDF 14 KB Posted

Attached to
CONSTRUCT CSMS PHASE II
Solicitation number
W91364-09-B-0002
Issued by

About this file

220519 meters and gages for plumbing piping.pdf

View the file

Other files

File Type Posted
Bid Abstract 09-B-0002.pdf PDF
09-B-0002 Amendment 4.pdf PDF
ADDENDUM NO 02 CSMS PH II Narrative SENT.pdf PDF
ADDENDUM NO 03 CSMS PH II Narrative.pdf PDF
09-B-0002 Amendment 2.pdf PDF
CSMS PH II Addendum.pdf PDF
Bid Questions CSMS phase II JACOBS RESPONSES JFK.doc DOC document
e1w13300.PDF PDF
L502.pdf PDF
CSMS268 Layout1 —
CSM-A721W .pdf PDF
CSM-G000W-VOL2.pdf PDF
CSMP404W.pdf PDF
CSMM312aW.pdf PDF
CSM-A102W .pdf PDF
C100.pdf PDF
CSM-I101W .pdf PDF
CSM-A421W .pdf PDF
C301.pdf PDF
CSMS218W Layout1 —
CSMP402W.pdf PDF
CSMM312cW.pdf PDF
C604.pdf PDF
CSM-A701W .pdf PDF
CSMP602W.pdf PDF
CSMF401W.pdf PDF
CSM-A810W .pdf PDF
CSM-A322W .pdf PDF
CSMF317W.pdf PDF
CSM-A323W .pdf PDF
C402.pdf PDF
CSM-G116W .pdf PDF
E-301.pdf PDF
CSM-A251W .pdf PDF
CSM-G126W .pdf PDF
E-418.pdf PDF
CSMS219W Layout1 —
E-706.pdf PDF
CSMS306W Layout1 —
CSM-A518W .pdf PDF
E-104.pdf PDF
CSMM005W.pdf PDF
CSMS303W Layout1 —
CSMM314aW.pdf PDF
E-105.pdf PDF
CSMM204W.pdf PDF
CSMM314cW.pdf PDF
CSMP311W.pdf PDF
CSM-A712W .pdf PDF
CSM-A822W .pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F5W61607 Combined Support Maintenance Shop - Phase II Ohio Army National Guard Rev. 0 Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

METERS AND GAGES FOR PLUMBING PIPING 220519 - 1

SECTION 220519 - METERS AND GAGES FOR PLUMBING PIPING

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section Includes:

1. Thermometers.

2. Test plugs.

B. Related Sections:

1. Division 22 Section "Facility Water Distribution Piping" for domestic water meters and combined domestic and fire-protection water-service meters outside the building.

2. Division 22 Section "Domestic Water Piping" for water meters inside the building.

1.3 SUBMITTALS

A. Product Data: For each type of product indicated.

B. Product Certificates: For each type of meter and gage, from manufacturer.

C. Operation and Maintenance Data: For meters and gages to include in operation and maintenance manuals.

PART 2 - PRODUCTS

2.1 LIQUID-IN-GLASS THERMOMETERS

A. Metal-Case, Compact-Style, Liquid-in-Glass Thermometers:

1. Basis-of-Design Product: Subject to compliance with requirements, provide comparable product by one of the following:

a. Marsh.

b. Trerice, H. O. Co.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

METERS AND GAGES FOR PLUMBING PIPING 220519 - 2

c. Weiss Instruments, Inc.

2. Standard: ASME B40.200.

3. Case: Cast aluminum; 9-inch nominal size.

4. Case Form: Back angle unless otherwise indicated.

5. Tube: Glass with magnifying lens and blue or red organic liquid.

6. Tube Background: Nonreflective aluminum with permanently etched scale markings.

7. Window: Plastic.

8. Stem: Aluminum or brass and of length to suit installation.

a. Design for Thermowell Installation: Bare stem.

9. Accuracy: Plus or minus 1 percent of scale range or one scale division, to a maximum of 1.5 percent of scale range.

2.2 THERMOWELLS

A. Thermowells:

1. Standard: ASME B40.200.

2. Description: Pressure-tight, socket-type fitting made for insertion into piping tee fitting.

2.3 PRESSURE GAGES

A. Direct-Mounted, Metal-Case, Dial-Type Pressure Gages:

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. AMETEK, Inc.; U.S. Gauge.

b. Ashcroft Inc.

c. Ernst Flow Industries.

d. Flo Fab Inc.

e. Marsh Bellofram.

f. Miljoco Corporation.

g. Noshok.

h. Palmer Wahl Instrumentation Group.

i. REOTEMP Instrument Corporation.

j. Tel-Tru Manufacturing Company.

k. Trerice, H. O. Co.

l. Watts Regulator Co.; a div. of Watts Water Technologies, Inc.

m. Weiss Instruments, Inc.

n. WIKA Instrument Corporation - USA.

o. Winters Instruments - U.S.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

METERS AND GAGES FOR PLUMBING PIPING 220519 - 3

B. Direct-Mounted, Plastic-Case, Dial-Type Pressure Gages:

1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

a. AMETEK, Inc.; U.S. Gauge.

b. Ashcroft Inc.

c. Flo Fab Inc.

d. Marsh Bellofram.

e. Miljoco Corporation.

f. Noshok.

g. Palmer Wahl Instrumentation Group.

h. REOTEMP Instrument Corporation.

i. Tel-Tru Manufacturing Company.

j. Trerice, H. O. Co.

k. Weiss Instruments, Inc.

l. WIKA Instrument Corporation - USA.

m. Winters Instruments - U.S.

2. Standard: ASME B40.100.

3. Case: Sealed type; plastic; 4-1/2-inch nominal diameter.

4. Pressure-Element Assembly: Bourdon tube unless otherwise indicated.

5. Pressure Connection: Brass, with NPS ¼, ASME B1.20.1 pipe threads and bottom-outlet type unless back-outlet type is indicated.

6. Movement: Mechanical, with link to pressure element and connection to pointer.

7. Dial: Nonreflective aluminum with permanently etched scale markings.

8. Pointer: Dark-colored metal.

9. Window: Plastic.

10. Accuracy: Grade A, plus or minus 1 percent of middle half of scale range.

2.4 GAGE ATTACHMENTS

A. Snubbers: ASME B40.100, brass; with NPS ¼, pipe threads. Include extension for use on insulated piping.

B. Valves: Brass or stainless-steel needle type.

2.5 TEST PLUGS

A. Basis-of-Design Product: Subject to compliance with requirements, provide comparable product by one of the following:

1. Flow Design, Inc.

2. National Meter, Inc.

3. Peterson Equipment Co., Inc.

4. Sisco Manufacturing Company, Inc.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

METERS AND GAGES FOR PLUMBING PIPING 220519 - 4

5. Trerice, H. O. Co.

6. Watts Regulator Co.; a div. of Watts Water Technologies, Inc.

7. Weiss Instruments, Inc.

B. Description: Test-station fitting made for insertion into piping tee fitting.

C. Body: Brass or stainless steel with core inserts and gasketed and threaded cap.

Include extended stem on units to be installed in insulated piping.

D. Thread Size: NPS 1/4 (DN 8), ASME B1.20.1 pipe thread.

E. Minimum Pressure and Temperature Rating: 500 psig at 200 deg F.

F. Core Inserts: Chlorosulfonated polyethylene synthetic and EPDM self-sealing rubber.

PART 3 - EXECUTION

3.1 INSTALLATION

A. Install thermowells with socket extending a minimum of 2 inches into fluid and in vertical position in piping tees.

B. Install thermowells of sizes required to match thermometer connectors. Include bushings if required to match sizes.

C. Install thermowells with extension on insulated piping.

D. Install direct-mounted thermometers in thermowells and adjust vertical and tilted positions.

E. Install direct-mounted pressure gages in piping tees with pressure gage located on pipe at the most readable position.

F. Install valve and snubber in piping for each pressure gage for fluids.

G. Install thermometers in the following locations:

1. Inlet and outlet of each water heater.

2. Inlet and outlet of each domestic hot-water storage tank.

H. Install pressure gages in the following locations:

1. Building water service entrance into building.

2. Inlet and outlet of each pressure-reducing valve.

Defense Supply Center Columbus, Ohio 30 January 2009 Bid Final

METERS AND GAGES FOR PLUMBING PIPING 220519 - 5

3.2 CONNECTIONS

A. Install meters and gages adjacent to machines and equipment to allow service and maintenance of meters, gages, machines, and equipment.

3.3 ADJUSTING

A. Adjust faces of meters and gages to proper angle for best visibility.

END OF SECTION 220519