Temp_Facility_Specs.pptx

PPTX presentation 2 MB Posted

Attached to
CST Temporary Building Structure Federal contract opportunity
Solicitation number
W912R1-17-Q-0017
Issued by
Department of the Army National Guard

About this file

Temp Facility Specs

View the file

Other files for this federal contract opportunity

Other files attached to CST Temporary Building Structure, newest first.
File Type Posted
CST_Salient_Characteristics_TEMP_BLDG_(rev_21_Aug_17).pdf PDF
Salient_Characteristics-_Revised.docx DOCX document
Cost_Proposal_Template.xls XLS spreadsheet
Salient_Characteristics_TEMP_BLDG_R.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

33rd CST WMD Temporary Facility Requirements (UCSb2 and TOC Trailer)

40’ Width

11’ Width 30’ Length 20’ Height 42’ Length

11’ Width 30’ Length 6’ W 6’ W 6’ W 6’ L 6’ L 42’ Length UCS b2 TOC Trailer

Vehicle Door Vehicle Door Facility Floor 42’ L x 40’ W x 20’ H Vehicle Doors (2x) 34’ W x 14’ H

120 VAC 15A outlets 3’ W

TOC Trailer Shore Power Outlet (Has it’s own breaker)

UCSb2 Shore Power Outlet (Has it’s own breaker)

Door Door N

Ortiz, Derek 1LT MIL USA (OD1MU) - Please make sure that these measurements are NOT including the building structure i.e. wall widith, etc.

N

Ortiz, Derek 1LT MIL USA (OD1MU) - By locating the facility here we will be able to move our other trailer, located in lot 9, here as well freeing up room in lot 9.

EXTERNAL LIGHTING

ENTRANCE

INTERNAL LIGHTING

ENTRANCE

50A Twist Lock Power Receptacle Required Power Feed: 120/240V 1PH 50A or 120/208V 3PH 50A Four Wire Connection (L1, L2, N, G)

UCSb2 Power Requirements FACILITY POWER OUTLET RECEPTACLE (Twist Lock, 50A, 125V/250V, 3 Pole, 4 Wire) Example PN from Ericson: CS6369

VEHICLE POWER INLET RECEPTACLE

10’ (120”)

29’– 7” (355”) 11’ – 8” (140”)

50A Twist Lock Power Receptacle Required Power Feed: 120/240V 1PH 50A or 120/208V 3PH 50A Four Wire Connection (L1, L2, N, G)

TOC Trailer Power Requirements FACILITY POWER OUTLET RECEPTACLE (Twist Lock, 50A, 125V/250V, 3 Pole, 4 Wire) Example PN from Ericson: CS6369

VEHICLE POWER INLET RECEPTACLE

10’ – 4” (124”) 11’ – 3” (135”) 8’- 4” (100”) 6,000lb Axle 27’– 1” (325”) 1,560lb (Heavy) 1,430lb (Light) Tongue

6,000lb Axle 28’ – 11” (347”) image1.png image2.jpeg image3.png image4.png image5.png image6.jpeg image7.jpeg image8.png image9.png