These are architectural and telecommunications design plan sheets for the Advanced Skills Training Barracks project at Parks Reserve Forces Training Area in California, prepared by the US Army Corps of Engineers Louisville District. The documents provide detailed interior finish specifications, telecommunications infrastructure requirements, and site layout plans for a 45,000 square foot barracks facility. Key design elements include two and three-person rooms, information systems, fire protection, video surveillance, electrical and mechanical systems, and comprehensive interior material and color specifications. The plans specify sustainable design features, accessibility accommodations, and antiterrorism force protection measures, with a focus on creating a durable facility designed to meet a 40-year service life standard. The telecommunications plans outline specific requirements for network infrastructure, including CAT6A cabling, wireless access points, and comprehensive labeling and testing protocols.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PP

PP

PP

M W

PP

X

X

DA

VI

S

AV

E.

BLDG 342

BLDG 340

PP

PP

T

PP

T

PP

CU

x

C U x

SSx SSx SSx

SS

x

EU

x

EU

x

EUx

EUx EUx

EU

x

EU

x

EUx

E x

E x

E x

E x

E x

W x

W x

W x

W x

W x

W x

W x

W x

W x

W x

W x

W x

W x

S

S S

F x

SS

SS

SS

SS

SS

S W F E C

CU CU CU

W

E

SS

SS

SS

W W W W

W

W

EU EU EU

F

SS SS SS SS

EU

EU

EU

F

S

S

S

S

S

NO

P

AR

KI

NG

FI

RE

LA

NE

.0'

N: 2087135.18 E: 6155192.02

BEGIN CURB

N: 2087185.41 E: 6154984.95

MATCH EXISTING

N: 2087027.60 E: 6155189.09

END CURB

5.0 '6.0'

N: 2087007.90 E: 6154966.68

MATCH EXISTING

N: 2087010.66 E: 6154867.79

MATCH EXISTING

5.0'

5.0'

N: 2087034.03 E: 6155141.88

18.5'

10 12

13.5'

12.0'

5.0

N: 2087036.64 E: 6155048.28

LIMITS OF DISTURBANCE/

CONSTRUCTION WORK LIMIT

N: 2087185.59 E: 6154978.95

MATCH EXISTING

36.0'

LIMITS OF DISTURBANCE/

CONSTRUCTION WORK LIMIT

AST BARRACKS

FFE: 374.00'

AT

FP

S

ET

BA

CK

21.3'

5.0

.0'

181.0'

N: 2087023.06 E: 6155033.93

N: 2087024.15 E: 6154995.13

14 14 14

5.0

5.0

5.0'

5.0

5.0

5.0'

5.0

5.0

6.0'

R10.0'

R4.0

5.9'

5.0

BASIN 1

BASIN 2

N: 2087124.85 E: 6154792.94

N: 2087060.87 E: 6154791.16

N: 2087051.09 E: 6155142.35

N: 2087115.06 E: 6155144.14N: 2087119.54

E: 6154983.33 N: 2087120.84 E: 6154936.78

10.0'

N: 2087060.44 E: 6154969.21

N: 2087060.13 E: 6154980.54

4.8'4.9'

13.7'

N: 2087080.51 E: 6155143.17

N: 2087089.67 E: 6155143.43

N: 2087137.27 E: 6155015.92

N: 2087137.67 E: 6155001.68

N: 2087099.46 E: 6154792.23

N: 2087135.18 E: 6154781.22

6" CURB DATA TABLE

# BEARING/DELTA RADIUS LENGTH

1 Δ=45°40'57" 10.00' 7.97' 2 N46°35'48"E -- 12.15' 3 Δ=45°00'00" 9.50' 7.46' 4 N01°35'48"E -- 61.89' 5 Δ=45°00'00" 9.50' 7.46' 6 N43°24'12"W -- 12.04' 7 Δ=45°03'30" 10.50' 8.26'

D R

AW

N

B Y:

L.

M

ED

IN

A

D

ES

IG

N

ED

B

Y:

S.

N G

U

YE

N

SU

BM

IT

TE

D B

Y:

J.

Z U

KO

W

SK

I

C H

EC

KE

D B

Y:

D

. P

EN

N

IN

G

TO

N

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

PL

O

T D

AT

E:

4/

/2

US Army Corps of Engineers ®

SHEET ID

SI

ZE

AN

SI

D

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

A R

K

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

AD

VA

N C

ED

S

KI

LL

S

TR

AI

N

IN

G

B

AR

R

AC

KS

PA

R

KS

R

ES

ER

VE

F O

R C

ES

T

R

AI

N

IN

G A

R

EA

IS

SU

E D

AT

E:

F

EB

R

U

AR

Y

FI

LE

N

AM

E:

U

S-

A- G

-C S1

GENERAL NOTES

KEY NOTES

PLAN NORTH

HORIZ. SCALE IN FEET

0 40'20'

C

ER

TI

FI

ED

F

IN

AL

S U

BM

IS

SI

O

N

P2

D

ES

C R

IP

TI

O N

LO

U

IS

VI

LL

E

D

IS

TR

IC

T

D

R M

AR

TI

N L

U

TH

ER

K

IN

G

J R

P L, LO

U

IS

VI

LL

E, K Y

M

IC

H

AE

L

BA

KE

R

IN

TE

R N

AT

IO

N

AL

, I N

C

AI

R

SI

D

E D

R

IV

E M

O O

N T

O W

N

SH

IP

, P

A

33' ATFP SETBACK

CONCRETE SIDEWALK PER DETAIL L15/CS501

ASPHALT CONCRETE PAVEMENT PER DETAIL K10/CS501

6" CONCRETE CURB PER DETAIL F10/CS501

STRIPING

BOLLARDS PER DETAIL G16/CS501

DRAINAGE SWALE PER DETAIL E16/CS501. SEE CG101 FOR MO

INFORMATION

12" DIAMETER ANGULAR RIP RAP

STORMWATER BASIN PER DETAIL J12/CS502, SEE CG101

BOOT WASH STATION PER A5/CS502

CONCRETE STAIRS AND HANDRAIL. HANDRAIL PER DETAIL D1/

CONCRETE EQUIPMENT PAD PER H1/S-501

ABA PATH OF TRAVEL

SPLASH BLOCK PER ARCHITECTURAL PLAN

STAIRS PER ARCHITECTURAL PLAN

A

M D

T

AP

R

IL

AP

R

IL

AP

R

IL

AP

R

IL

A

M D

T

W

2Q R

R

_P la ns -0

US Army Corps of Engineers ®

F ile

P a th

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N S

IZ

E

A

N S

I D

F

IL

E N

A M

E

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

M

IC

H A

E L B

A K

E R

I N

T E

R N

A T

IO

N

A L

IN

C

A

IR

S

ID

E

D R

IV

E

M O

O N

T O

W N

S H

IP

P

A

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

B

IM

/1 L

R L C a m p P a rk s A

S T

B a rr a c k s /1

C a m p P a rk s A

S T

B a rr a c k s I.

rv t

U S

-9 A

-I N

IN

T

E R

IO

R

F

IN

IS

H

IN

T E

R

IO

R M

A T

E R

IA

L A

N D

C O

L O

R B

A S

IS

O

F D

E S

IG

N

S

C H

E D

U L E

S A

N D

N O

T E

S

IN001

A D

V A

N C

E D

S K

IL

L S

T R

A

IN

IN

G

B A

R R

A C

K S

P A

R K

S R

E S

E R

V E

F O

R C

E S

T R

A

IN

IN

G

A R

E A

P

C E

R T

IF

IE

D F

IN

A

L S

U B

M

IS

S

IO

N

S K

O O

N T

Z

S K

O O

N T

Z

J Z

U K

O W

S K

I

A M

Y E

R S

F

E B

R U

A R

Y

SCHEDULE - INTERIOR MATERIAL AND COLOR BASIS OF DESIGN

FINISH DESCRIPTION MANUFACTURER STYLE COLOR SIZE COMMENTS

ACP1 ACOUSTICAL - CEILING PANEL (GRID LAY) ARMSTRONG 2822 CALLA, SQUARE TEGULAR WHITE 24" X 24" X 1" 15/16" GRID FACE

BB1 BULLETIN BOARD CLARIDGE PRODUCTS CLASSIC BULLETIN BOARD CABINET SATIN ANODIZED ALUMINUM FRAME; FAWN

1110 CORK

48" X 60" 2 DOORS, Z-BAR HANGERS. REFER TO PLAN FOR LOCATION

CS1 CONCRETE - SEALED - - CLEAR 3 COATS MINIMUM

EC1 EPOXY COATING RESUFLOR DECO QUARTZ BC23 CASHMERE WRAP UP WALLS 6"H BASE. CAP WITH SCHLUTER TRIM

EC2 EPOXY COATING (ACCENT) RESUFLOR DECO QUARTZ BC23 WARM BEACH WRAP UP WALLS 6"H BASE. CAP WITH SCHLUTER TRIM

ECS1 EPOXY COATING - STATIC DISSIPATIVE RESUFLOR 3725 STATIC CONTROL EPOXY COATING 78 SANDY BEIGE WRAP UP WALLS 6"H BASE. CAP WITH SCHLUTER TRIM

EM1 ENTRANCE MAT - RECESSED CS GROUP PEDIMAT AA M2 RECESS MOUNTED THRESHOLD FRAME 9327 DRY BROWN 7/16" D. HEAVY DUTY CARPET TREADS

GR1 GROUT - FLOORS LATICRETE SPECTRALOCK EPOXY 60 DUSTY GREY

GR2 GROUT - WALLS LATICRETE SPECTRALOCK EPOXY 90 LIGHT PEWTER

LVT1 LUXURY VINYL TILE MANNINGTON COMMERCIAL AMTICO STONE, 40 MIL JURA GRAY 18" X 36" INSTALLATION: BRICK ASHLAR

N/A SIGNAGE 2/90 SLIDE REFER TO DETAIL J13/IG501

N/A TRANSITIONS - METAL SCHLUTER VARIES AE SATIN ANODIZED ALUMINUM

N/A TRANSITIONS - RESILIENT TARKETT VARIES 283 TOAST

P1 PAINT - FIELD SHERWIN WILLIAMS EGGSHELL FINISH SW7009 PEARLY WHITE

P2 PAINT - ACCENT SHERWIN WILLIAMS EGGSHELL FINISH SW6060 MORROCAN SPICE

P3 PAINT - CEILING / BULKHEADS SHERWIN WILLIAMS FLAT FINISH, EPOXY - GLOSS FINISH SW7757 HIGH REFLECTIVE WHITE EPOXY, MOISTURE RESISTANT GLOSS AT RESTROOMS, SHOWERS AND JANITOR

P4 PAINT - TRIM / DOORS / INTERIOR HANDRAILS SERHWIN WILLIAMS EGGSHELL FINISH SW7025 BACKDROP

PL1 PLASTIC LAMINATE FORMICA STANDARD FINISH 5489 ESPRESSO PEAR INSTALLATION: VERTICAL WOOD GRAIN

PT1 PORCELAIN TILE - FLOORS DALTILE DIGNITARY DR08 SUPERIOR TAUPE, TEXTURED 24" X 24" X 5/16" INSTALLATION: HORIZONTAL STRAGHT LAY

PT2 PORCELAIN (CERAMIC) TILE - WALLS PORCELANOSA VERBIER, RECTIFIED SAND 18" X 47" X 3/8" SCHLUTER TRIM AS REQUIRED

PT3 PORCELAIN (CERAMIC) TILE - WALL ACCENT PORCELANOSA THAO VERBIER SAND 18" X 47" X 3/8" SCHLUTER TRIM AS REQUIRED

RB1 RESILIENT BASE TARKETT BASEWORKS THERMOSET RUBBER (TYPE TS) 283 TOAST 4"H CONTINUOUS ROLL; PROVIDE TOE ON HARD SURFACE FLOORING

RT1 RUBBER TREADS, RISERS, STRINGERS AND LANDING

SYSTEM

NORA SYSTEMS NORAMENT ARAGO TREAD 5178 CALM LANDING: 20" X 40"

TILES

INTEGRAL RISERS AND RUBBER STRINGERS; BLACK STRIP ON STAIR TREAD

SH1 SHOWER CURTAIN CS-GROUP CS HOOKLESS SHOWER CURTAIN, FABRIC, LITCHFIELD WHITE 84”H USE WITH STAINLESS STEEL BREAKAWAY ROD

SS1 SOLID SURFACE - COUNTERTOP CORIAN EASED EDGE (WHERE APPLICABLE) ARTISTA CANVAS 1/2" TH. REFER TO P-SERIES FOR SINK COORDINATION

SS2 SOLID SURFACE - WINDOW STOOL CORIAN EASED EDGE (WHERE APPLICABLE) GLACIER ICE 1/2" TH.

TZ1 TERRAZZO SHOWER PAN FIAT PRODUCTS - 100 WHITE PORTLAND CEMENT WITH WHITE

CHIPS

SEE P-SERIES DRAWINGS FOR FIXTURE SCHEDULE

WP1 WALL PROTECTION - CORNER GUARD CS GROUP ACROVYN SM20 934 PEARL 3" WING; 6'H MOUNT DIRECTLY ABOVE WALL BASE TOP

WP2 WALL PROTECTION - RIGID WALL PANEL WAINSCOT CS GROUP ACROVYN WALL COVERING 934 PEARL 4' X 8' RAILROADED; PROVIDE MATCHING VINYL TRIM & TOP CAP, INSIDE AND OUTSIDE CORNERS

WP3 WALL PROTECTION - CHAIR RAIL CS GROUP ACROVYN SCR-40N 315 GALVESTON GRAY 4"H X 3/4" SEE IN-501 FOR DETAILS

WP4 WALL PROTECTION - WALL GUARD CS GROUP ACROVYN SCR-40MN 315 GALVESTON GRAY 4"H SEE IN-501 FOR DETAILS

WT1 WINDOW TREATMENT - DUAL ROLLER SHADE/ROOM

DARKENING

MECHO SHADE SOHO 1900 SERIES 5% OPEN / CHELSEA BLACKOUT 1904 SAND, 0252 SAND ALL EXTERIOR WINDOWS U.N.O

NOTES - INTERIOR FINISH

1 SEE TECHNICAL SPECIFICATIONS AND INTERIOR FINISH

DRAWINGS FOR INTERIOR FINISH INFORMATION.

2 INTERIOR ELEVATIONS SHOWN IN THE 'IN' SERIES ARE

FOR FINISH LOCATIONS ONLY. REFER TO

ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND

CONSTRUCTION INFORMATION.

3 REFER TO ARCHITECTURAL PLANS FOR STANDARD

MOUNTING HEIGHTS OF BATHROOM ACCESSORIES AND

FIXTURING. DIMENSIONS PROVIDED IN FINISH

DRAWINGS ARE FOR FINISH EXTENTS ONLY.

4 ALL FLOOR LEVEL CHANGES ARE TO HAVE PROPER

TRANSITIONS AS REQUIRED.

5 FLOOR TRANSITIONS ARE COORDINATED WITH

SELECTED PRODUCTS AND INSTALLED PER

MANUFACTURER’S RECOMMENDATIONS.

6 CONTRACTOR TO ENSURE INSTALLED TRANSITIONS

ARE BARRIER FREE.

7 ALL FLOOR FINISH MATERIAL CHANGES OCCURRING AT

A DOOR, WILL TRANSITION AT THE CENTERLINE OF THE

DOOR SLAB, WHILE DOOR IS IN THE CLOSED POSITION,

U.N.O.

8 ALL FLOOR FINISH MATERIAL CHANGES OCCURRING AT

A CASED OPENING, WILL TRANSITION AT THE

CENTERLINE OF CASEMENT OPENING/WALL THICKNESS,

U.N.O.

9 BUTT JOINT DIFFERENT FLOOR FINISH STYLES/COLORS

OF THE SAME MATERIAL AND THICKNESS, U.N.O.

10 SEE PLUMBING DRAWINGS FOR PLUMBING FIXTURE

SPECIFICATION.

11 ELEVATOR CAB FINISHES ARE COORDINATED WITH

MANUFACTURER DURING SHOP DRAWINGS.

12 SEE ARCHITECTURAL DETAIL DRAWINGS FOR INTERIOR

CASEWORK AND ADDITIONAL FINISH CONSTRUCTION

DETAILS, A-SERIES

13 SEE SPECIFICATIONS SECTION 09 90 00 FOR PAINT

SYSTEM REQUIREMENTS. PAINTS ARE LOW VOC.

14 PAINT INTERIOR HOLLOW METAL DOORS AND / OR

HOLLOW METAL FRAMES IN A SEMI-GLOSS FINISH, SEE

MATERIAL AND COLOR SCHEDULE FOR PAINT COLOR.

15 REFER TO INTERIOR FINISH DRAWINGS FOR ACCENT

WALL LOCATIONS / EXTENTS.

16 ALL WALLS ARE PAINTED FROM TRUE FLOOR TO DECK

OR UNDERSIDE OF FLOOR SLAB ABOVE.

17 PAINT EXTERIOR HOLLOW METAL DOORS AND/OR

HOLLOW METAL FRAMES IN A SEMI-GLOSS FINISH, SEE

MATERIAL AND COLOR SCHEDULE FOR PAINT COLOR.

18 PAINT EXPOSED CEILINGS ENTIRELY; INCLUDING

EXPOSED STRUCTURE, DECK, DUCTWORK, CONDUIT,

PIPING, ETC. GYPSUM BOARD CEILINGS AND SOFFITS

ARE PAINTED AS SCHEDULED. REFER TO OTHER

DISCIPLINE DRAWINGS FOR CODE RELATED COLORS OF

PIPING, ETC.

19 PAINT METAL GRILLES, DIFFUSERS, PANEL BOXES AND

REGISTERS LOCATED WITHIN OCCUPIED AREAS TO

MATCH THE ADJACENT WALL FINISH AS NOTED ON THE

FINISH SCHEDULES AND DRAWINGS.

20 SEE TECHNICAL SPECIFICATIONS AND MATERIAL AND

COLOR SCHEDULE FOR STAIR FINISHES.

21 REFER TO ARCHITECTURAL REFLECTED CEILING

PLANS, AR-SERIES, FOR CEILING HEIGHTS.

SCHEDULE - INTERIOR FINISH - 1ST FLOOR

ROOM

BASE FLOOR WALL CEILING COMMENTSNUMBER NAME

101 SEO RB1 LVT1 P1 ACP1

126 STUDY AREA RB1 LVT1 P1 / P2 / WP1 / WP3 ACP1 PL1, SS1, PT3 REFER TO PLAN, SEE

DETAIL B11/IN501

127 MECH - CS1 P1 P3

128 ELEC - CS1 P1 P3

129 LAUNDRY RB1 CS1 P1 / WP2 / WP3 P3 REFER TO PLAN, SEE DETAIL B11/IN501

129A DRYER ACCESS RB1 CS1 P1 P3

130 TELECOM - ECS1 P1 P3

C010 CORRIDOR - EC1 P1 / WP1 / WP2 /

WP3 / WP4

ACP1 SEE DETAIL B11/IN501

C011 CORRIDOR - EC1 P1 / WP1 / WP2 /

WP3 / WP4

ACP1 SEE DETAIL B11/IN501

EL-A1 ELEV - LVT1 - -

G010 JAN RB1 CS1 P1 / PT2 P3 PT2 - 4'H

G011 STOR - CS1 P1 ACP1

G012 EMR - CS1 P1 P3

G013 RR - EC1 P1 / PT2 P3 SEE DETAIL B6/IN501

L010 LOBBY - EC1 P1 / WP1 / WP2 /

WP3 / WP4

P3 SEE DETAIL B11/IN501

ST-A1 STAIR RB1 EC1 / RT1 P1 P3 RB1 WITH RT1

V010 VEST RB1 EM1 P1 P3

V011 VEST RB1 EM1 P1 P3

SCHEDULE - INTERIOR FINISH - BATH, TYPICAL

ROOM

BASE FLOOR WALL CEILING COMMENTSNAME

BATH SEE

G1/IN501

PT1 PT2 / PT3 P3 TZ1; PT2 / PT3 SHOWER SURROUND, SEE DETAIL B1/IN501

AND ENLARGED PLANS IN401 FOR ACCENT TILE LOCATIONS

SCHEDULE - INTERIOR FINISH - BEDROOMS, TYPICAL

ROOM

BASE FLOOR WALL CEILING COMMENTSNAME

BEDROOM RB1 LVT1 P1 / P2 P3 PL1, SS1, PT3 REFER TO ENLARGED PLAN

SCHEDULE - INTERIOR FINISH - 2ND FLOOR

ROOM

BASE FLOOR WALL CEILING COMMENTSNUMBER NAME

-- EXTERIOR

226 STUDY AREA RB1 LVT1 P1 / P2 / WP1 / WP3 ACP1 PL1, SS1, PT3 REFER TO PLAN, SEE

DETAIL B11/IN501

227 MECH - CS1 P1 P3

228 ELEC - CS1 P1 P3

229 LAUNDRY RB1 CS1 P1 / WP2 / WP3 P3 REFER TO PLAN, SEE DETAIL G11/IN501

229A DRYER ACCESS RB1 CS1 P1 P3

230 TELECOM - ECS1 P1 P3

C020 CORRIDOR - EC1 P1 / WP1 / WP2 /

WP3 / WP4

ACP1 SEE DETAIL B11/IN501

C021 CORRIDOR - EC1 P1 / WP1 / WP2 /

WP3 / WP4

ACP1 SEE DETAIL B11/IN501

EL-A1 ELEV - LVT1 - -

G020 JAN RB1 CS1 P1 / PT2 P3 PT2 - 4'H

G021 STOR - CS1 P1 ACP1

L020 LOBBY - EC1 P1 / WP1 / WP2 /

WP3 / WP4

P3 SEE DETAIL B11/IN501

ST-A2 STAIR RB1 EC1 / RT1 P1 P3 RB1 WITH RT1

A

M D

T

A

P R

IL

A

M D

T

A

P R

IL

W

2Q R

R

_P la ns -0

BEDROOM

204A

BATH

203A

BATH

EL-A1

ELEV

202A

BATH

201A

BATH

232A

BATH

231A

BATH

TELECOM

G021

STOR

G020

JAN

L020

LOBBY

BEDROOM

ST-A2

STAIR

STUDY

AREA

BEDROOM

MECH

ELEC

BEDROOM

229A

DRYER

ACCESS

IN

IN

IN

IN

6 7 8 9

D

B

C

A

WP1WP1

WP1WP1

WP1WP1

WP1WP1

WP1WP1

WP1WP1

WP1WP1

LAUNDRY

P2

EC1

RT1

PT3

IN401

B11 Sim

3'

T Y

P

3'

T Y

P

BB1BB1 3' - 0"

9.03

BEDROOM

LEGEND - INTERIOR FINISH (FLOOR)

EC2 (ACCENT)

EC1

LEGEND - INTERIOR FINISH (TAG)

WALL FINISH TAGXX#

A B C

PLAN

NORTH

US Army Corps of Engineers ®

KEYPLAN

GRAPHIC SCALE NORTH ARROW

F ile

P a th

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N S

IZ

E

A

N S

I D

F

IL

E N

A M

E

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

M

IC

H A

E L B

A K

E R

I N

T E

R N

A T

IO

N

A L

IN

C

A

IR

S

ID

E

D R

IV

E

M O

O N

T O

W N

S H

IP

P

A

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

B

IM

/1 L

R L C a m p P a rk s A

S T

B a rr a c k s /1

C a m p P a rk s A

S T

B a rr a c k s I.

rv t

U S

-9 A

-I N

IN

T

E R

IO

R

F

IN

IS

H

S

E C

O N

D F

L O

O R

P L A

N

A R

E A

B

IN122

A D

V A

N C

E D

S K

IL

L S

T R

A

IN

IN

G

B A

R R

A C

K S

P A

R K

S R

E S

E R

V E

F O

R C

E S

T R

A

IN

IN

G

A R

E A

P

C E

R T

IF

IE

D F

IN

A

L S

U B

M

IS

S

IO

N

S K

O O

N T

Z

S K

O O

N T

Z

J Z

U K

O W

S K

I

A M

Y E

R S

F

E B

R U

A R

Y

SCALE: 1/8" = 1'-0"

INTERIOR FINISH - SECOND FLOOR PLAN - AREA B

C5

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

KEYNOTES

9.03 REFER TO H5/A404 FOR EXTENT OF WALL TILE

A

M D

T

A

P R

IL

W

2Q R

R

_P la ns -0

ABBREVIATIONSSYMBOL SECURITY GENERAL NOTESSYMBOL TELECOMMUNICATIONS

TELECOMMUNICATIONS STANDARDS

TELECOMMUNICATIONS OUTLET, 8P8C TYPE CONNECTOR, FACEPLATE

MOUNTED AT 18" AFF UNO.

+ DENOTES ABOVE FINISHED FLOOR HEIGHT.

2 DENOTES TWO (2) BLUE CAT6A UTP COPPER CABLES

TERMINATED TO A SINGLE GANG FACEPLATE.

DDC DENOTES TWO (2) BLUE CAT6A UTP COPPER CABLES

TERMINATED TO A SINGLE GANG FACEPLATE.

FACP DENOTES TWO (2) BLUE CAT6A UTP COPPER CABLES

TERMINATED TO A SINGLE GANG FACEPLATE.

ELEV DENOTES TWO (2) BLUE CAT6A UTP COPPER CABLES

TERMINATED TO A SINGLE GANG FACEPLATE.

TELECOMMUNICATIONS OUTLET, 8P8C TYPE, FACEPLATE MOUNTED AT

48" AFF UNO.

+ DENOTES ABOVE FINISHED FLOOR HEIGHT.

V DENOTES ONE (1) BLUE POTS CAT6A COPPER CABLE AND ONE

(1) VOIP CAT6A COPPER CABLE TERMINATED TO A SINGLE

GANG FACEPLATE.

2 DENOTES 2-WAY COMMUNICATION BOX CONSISTING OF ONE

(1) BLUE POTS CAT6A CABLE TERMINATED TO A SINGLE GANG

FACEPLATE.

CATV/TELEVISION DISPLAY OUTLET, 8P8C-TYPE AND F-TYPE

CONNECTORS, FACEPLATE MOUNTED AT 18" AFF UNO.

+ DENOTES ABOVE FINISHED FLOOR HEIGHT.

TV DENOTES ONE (1) RG-6 COAX CABLE TERMINATED TO A SINGLE

GANG FACEPLATE. CABLING INSIDE OF TELECOMMUNICATIONS

TO BE COILED FOR FUTURE TERMINATION BY SYSTEM OWNER.

ARNEC WIRELESS ACCESS POINT OUTLET, WALL MOUNTED. MOUNTED IN

ACCESSIBLE CEILING SPACE, 18" ABOVE FINISHED CEILING. EACH

WIRELESS ACCESS POINT OUTLET LOCATION TO CONSIST OF TWO (2)

BLUE CAT6A UTP COPPER CABLES, 8P8C TYPE CONNECTOR,

TERMINATED TO A SINGLE GANG FACEPLATE.

ARNEC WIRELESS ACCESS POINT OUTLET, WALL MOUNTED. MOUNTED IN

NON-ACCESSIBLE CEILING SPACE, 8' AFF. EACH WIRELESS ACCESS

POINT OUTLET LOCATION TO CONSIST OF TWO (2) BLUE CAT6A UTP

COPPER CABLES, 8P8C TYPE CONNECTOR, TERMINATED TO A SINGLE

GANG FACEPLATE.

BOINGO COMMERICAL WIRELESS ACCESS POINT OUTLET, CEILING

MOUNTED. EACH WIRELESS ACCESS POINT OUTLET LOCATION TO

CONSIST OF ONE (1) GREEN CAT6A UTP COPPER CABLE, 8P8C TYPE

CONNECTOR. TERMINATED TO A SINGLE-PORT SURFACE MOUNT BOX

INSIDE OF A 5" SQUARE BY 2-7/8" OUTLET BOX.

TELECOMMUNICATIONS NETWORK RACK, 2-POST, 45U, FLOOR MOUNTED.

PBB OR SBB, AS INDICATED ON PLANS.

BASKET CABLE TRAY, WELDED WIRE TYPE FOR DISTRIBUTION OF

CABLING OUTSIDE OF THE TELECOMMUNICATION ROOM, SIZE INDICATED

ON PLANS.

LADDER RUNWAY FOR DISTRIBUTION OF CABLING INSIDE OF THE

TELECOMMUNICATIONS ROOM, SIZE INDICATED ON PLANS.

TELECOMMUNICATIONS CEILING ACCESS PANEL, 2'X2'.

SYMBOL GENERAL

SHEET KEYNOTE

X = KEYNOTE NUMBER

X

DESIGNATED MOUNTING LOCATION FOR ACCESS CONTROL

SYSTEM PANEL.

DESIGNATED LOCATION FOR ACCESS CONTROL SYSTEM

COMPONENTS.

ACS-P

ACS

8 POSITION, 8 CONTACT CONNECTOR

110 PUNCHDOWN BLOCKS

ACCESS CONTROL SYSTEM

AMERICANS WITH DISABILITIES ACT

ABOVE FINISHED FLOOR

ABOVE FINISHED GROUND

AMERICAN NATIONAL STANDARD INSTITUTE

AUDIO VISUAL

AMERICAN WIRE GAGE

BACKBONE BONDING CONDUCTOR

BUILDING

BALANCED MAGNETIC SWITCH

CONDUIT

CATEGORY 6 CABLE

COMMUNITY ANTENNA TELEVISION (CABLE)

CONTRACTOR FURNISHED CONTRACTOR INSTALLED

CLASSIFIED

CEILING

COMMUNICATION

CONTROL PANEL

CARD READER

CABLE TRAY

COPPER

DIRECT DIGITAL CONTROL

DOOR POSITION SWITCH

DETAIL

DRAWING

EACH

ELECTRIC HINGE

ENTRANCE FACILITY

ELECTRIC LOCK

ELECTRICAL

ELECTRICAL METALLIC TUBING

ELECTRICAL NONMETALLIC TUBING

EQUIPMENT

EQUIPMENT ROOM

ELECTRIC STRIKE

FOILED UNSHIELDED TWISTED PAIR

FIRE ALARM

FIBER OPTIC DISTRIBUTION UNIT

FLEXIBLE METAL CONDUIT

FIBER OPTIC

FIBER OPTIC CABLE

GOVERNMENT FURNISHED/GOVERNMENT INSTALLED

GALVANIZED RIGID CONDUIT

HIGH DEFINITION

HIGH-DENSITY POLYETHYLENE

IN ACCORDANCE WITH

INTERMEDIATE METAL CONDUIT

INGRESS PROTECTION

LOCAL ALARM

LOW VOLTAGE

MAGNETIC LOCK

TELECOMMUNICATIONS MANHOLE

MINIMUM

MISCELLANEOUS

MULTIMODE

MOUNT/MOUNTED

NOT APPLICABLE

NATIONAL ELECTRICAL CODE

NATIONAL FIRE PROTECTION ASSOCIATION

NOT TO SCALE

ON CENTER

OVERHEAD

OUTSIDE PLANT

PUSHBUTTON

PRIMARY BONDING BUSBAR

PROTECTED ENTANCE TERMINALS

POWER OVER ETHERNET

PAN-TILT-ZOOM

POLYVINYL CHLORIDE

QUANTITY

REGISTERED COMMUNICATIONS DISTRIBUTION DESIGNER

RIGID GALVANIZED STEEL

ROOM

RIGID METAL CONDUIT

REQUEST TO EXIT

SECONDARY BONDING BUSBAR

SCHEDULE

SINGLE-MODE FIBER OPTIC

SPECIFICATION

STRAND

TO BE DETERMINED

TELECOMMUNICATIONS ENTRANCE FACILITY

TELECOMMUNICATION

TELECOMMUNICATIONS INDUSTRY ASSOCIATION

TWISTED PAIR

TELECOMMUNICATIONS ROOM

TELEVISION

TYPICAL

UNCLASSIFIED

UNDERFLOOR

UNDERGROUND

UNLESS NOTED OTHERWISE

UNINTERRUPTIBLE POWER SUPPLY

VOICE & DATA

WALL PHONE

WITH

WITHOUT

WORK AREA OUTLET

WIRELESS ACCESS POINT

WEATHERPROOF

1. THIS IS A STANDARD LEGEND SHEET. NOT ALL SYMBOLS OR ABBREVIATIONS MAY APPEAR ON

DRAWINGS.

2. MOUNTING HEIGHTS, UNLESS OTHERWISE NOTED, ARE TO CENTER LINE OF DEVICE.

3. THE CONTRACTOR SHALL DETERMINE THE EXACT ROUTING OF RACEWAYS.

4. THE CONTRACTOR SHALL COORDINATE ALL CONDUIT PENETRATIONS AND PROVIDE

FIREPROOFING AND HAZARDOUS AREA CONDUIT SEALS AS APPLICABLE.

5. THE MAXIMUM PERMANENT HORIZONTAL LINK DISTANCE SHALL BE 295 FEET AND THE

MAXIMUM HORIZONTAL CHANNEL (LINK PLUS WORKSTATION CABLES AND PATCH CORDS) SHALL

BE 325 FEET.

6. HORIZONTAL VOICE AND DATA CABLING SHALL BE CAT6A UTP UNLESS OTHERWISE SPECIFIED

ON DRAWING SHEETS OR IN SYMBOL DESCRIPTIONS.

7. HORIZONTAL VOICE AND DATA CABLING SHALL BE INSTALLED IN A MINIMUM 1-INCH CONDUIT

FROM TELECOMMUNICATIONS OUTLET LOCATIONS TO THE BASKET CABLE TRAY.

8. CAT6A UTP CABLING SHALL BE TERMINATED ON 8-PIN, 8-CONDUCTOR (RJ-45) CONNECTORS

USING PIN/PAR ASSIGNMENTS IN ACCORDANCE WITH T568A PIN-OUT SEQUENCE.

9. HORIZONTAL AND VERTICAL ISP BACKBONE CABLING SHALL BE PLENUM RATED. SEE NOTE 10

FOR OSP BACKBONE CABLES INSTALLED IN UNDERGROUND CONDUITS. ALL COMMUNICATIONS

MATERIALS/COMPONENTS ARE TO BE UL LISTED OR NRTL CERTIFIED, UNLESS OTHERWISE

SPECIFIED IN DESIGN DOCUMENTATION.

10. PROVIDE CABLE INSTALLED IN UNDERGROUND OR UNDERSLAB CONDUITS LISTED FOR USE IN

WET LOCATIONS WITH A WATER BLOCKING COMPOUND. PLENUM RATED CABLE SHALL NOT BE

INSTALLED IN ANY UNDERGROUND OR UNDERSLAB CONDUIT.

11. PROVIDE PULL CORD IN ALL SPARE DUCTS AND INNER-DUCTS.

12. THE USE OF J-HOOKS SHALL NOT BE ALLOWED.

13. BASKET CABLE TRAY SHALL BE WALL MOUNTED (PREFERABLE) OR TRAPEZE MOUNTED.

14. PROVIDE ACCESS PANELS IN NON LAY-IN CEILINGS SUCH THAT NO POINT IN THE CABLE TRAY

SYSTEM IS MORE THAN 6 FEET FROM AN ACCESS PANEL.

15. PROVIDE A MINIMUM OF 12 INCHES OF CLEARANCE ABOVE THE TOP OF BASKET CABLE TRAYS, A MINIMUM OF 12 INCHES OF CLEARANCE ON AT LEAST ONE SIDE OF BASKET CABLE TRAYS, AND

A MINIMUM OF 3 INCHES CLEARANCE BELOW BASKET CABLE TRAYS.

16. PROVIDE MODULAR, FIRE-RATED WALL PENETRATION ASSEMBLIES.

17. COMPLY WITH TIA-569-E ENVIRONMENTAL STANDARDS IN TELECOMMUNICATION SPACES.

18. USE ONLY COPPER CONDUCTORS FOR GROUND CONNECTIONS. THE USE OF ALUMINUM

CONDUCTORS IS NOT ALLOWED.

19. LABEL ALL CABLE TERMINATIONS AND BOTH ENDS OF ALL CABLES IN ACCORDANCE WITH

TIA-606-C-1.

20. PROVIDE AS-BUILT DOCUMENTATION INCLUDING BACKBONE AND HORIZONTAL OPTICAL FIBER

AND COPPER TEST RESULTS AND CERTIFICATION TEST RESULTS IN ACCORDANCE WITH

INDUSTRY STANDARDS AND MANUFACTURER'S GUDELINES. PROVIDE FLOOR PLANS SHOWING

USER WORKSTATIONS WITH CABLING LABELING, AND BACKBONE CABLE SCHEMATIC AND

LABELING IN PDF FORMAT AND A PRINTED HARDCOPY. TEST RESULTS WILL CONSIST OF A PDF FILE DOWNLOADED FROM THE TEST EQUIPMENT AND AN EXCEL FORMATTED FILE. FOR OSP, ALL AS-BUILTS WILL BE PROVIDED ELECTRONICALLY IN CAD DWG FILE, PDF FORMATS AND INCLUDE

GPS MAPPING AND PAPER COPIES. PROVIDE DESIGNER OF RECORD OR COMMISSIONING AGENT

THE NATIVE TEST FILES UPON REQUEST.

21. THE FOLLOWING SHALL BE PROVIDED AND INSTALLED BY THE GOVERNMENT (GFGI):

A. TELECOM RACK ACTIVE EQUIPMENT (SERVERS, ROUTERS, SWITCHES, MODEMS)

B. TELECOM RACK PATCH CABLES (BETWEEN SERVERS, ROUTERS, SWITCHES)

C. FACILITY TELEPHONE SWITCH EQUIPMENT

D. TELEPHONE HANDSETS AND PATCH CABLE TO WALL JACK

E. ELECTRONIC SECURITY SYSTEM (ESS) EQUIPMENT

F. FRONT END EQUIPMENT AND EQUIPMENT RACKS ASSOCIATED WITH CATV/CCTV/SATELLITE

TV, AND SEPARATE FRONT END AUDIO EQUIPMENT NOT ASSOCIATED WITH A COMBINED MASS

NOTIFICATION AND PAGING SYSTEM.

22. CONTRACTOR SHALL COORDINATE WITH GOVERNMENT ON GFGI ITEM REQUIREMENTS AND

PROVIDE SUITABLE STRUCTURAL SUPPORT, BRACKETS, ALL UTILITY CONNECTIONS AND SPACE

WITH REQUIRED CLEARANCES FOR GFGI ITEMS.

23. PROVIDE CABLE TERMINATIONS INCLUDING CONNECTORS, COUPLERS, FIBER ENCLOSURES,

PATCH PANELS, STRESS RELIEF, AND WIRE MANAGEMENT ACCORDING TO THE STANDARD

DETAILS.

24. INSTALL 5 INCH RADIUS DROPOUTS (WATERFALLS) FOR ANY CABLING TRAVERSING DOWN

FROM THE LADDER RUNWAY INSIDE OF TELECOMMUNICATION SPACES.

25. LOCATE AND INSTALL CONDUIT SLEEVES FOR COMMUNICATION CABLING THROUGH WALLS

INTO ENCLOSED SPACES AND THROUGH FLOOR PENETRATIONS. SLEEVES PROVIDED SHALL BE

SIZED ACCORDING TO THE NUMBER OF CABLES PASSING THROUGH.

26. INSTALL PULL STRING IN ALL CONDUITS AT THE TIME OF CONDUIT INSTALLATION.

27. COMMUNICATON PATHWAY SUPPORTING METHODS WILL FOLLOW LOCAL CODES REQUIRED

FOR THE SEISMIC ZONE. BRACING WILL BE FIELD LOCATED AND COORDINATED WITH OTHER

TRADES PRIOR TO INSTALLATION.

28. PREMISE CABLING TO INCLUDE INTRABUILDING BACKBONE CABLING MUST CONFORM AND BE

INSTALLED TO THE SPECIFICATIONS DEFINED BY UFGS 27 10 00, UFC 3-580-01, AND THE

MANUFACTURER INSTALLATION GUIDELINES TO INCLUDE, BUT NOT LIMITED TO:

A. TERMINATION POSITION/JACKET REMOVAL.

B. BEND RADIUS FOR UTP AND OPTICAL FIBER.

C. MANUFACTURER-RECOMMENDED CABLE PULLING TENSION.

29. COORDINATE MOUNTING HEIGHTS WITH FIELD CONDITIONS, OTHER TRADES, AND RELATED

EQUIPMENT.

30. PROVIDE CABLE SLACK WHICH IS A MINIMUM OF 10 FEET IN THE TELECOMMUNICATIONS

SPACE, A MINIMUM OF 3 FEET AT THE BASKET CABLE TRAY/CONDUIT TRANSITION, AND A

MAXIMUM OF 1 FOOT AT THE WORK AREA OUTLET FOR ALL CAT6A HORIZONTAL CABLING. COIL

CABLE IN A FIGURE-8 OR OBLONG CIRCLE TO PREVENT EMI INTERFERENCE.

31. TELECOMMUNICATION OUTLETS WILL UTILIZE OUTLET BOXES AT ALL APPLICABLE LOCATIONS.

AT LOCATIONS WITH GYPSUM, A 5" SQUARE OUTLET BOX WILL BE UTILIZED. AT LOCATIONS WITH

CMU, A 4-11/16" SQUARE OUTLET BOX WILL BE UTILIZED.

32. BOINGO COMMERCIAL WAP OUTLETS SHALL BE INSTALLED A MINIMUM OF 18" AWAY FROM

CEILING/WALL EDGES, BATHROOMS, AND ENTRY ROOMS AS WELL AS A MINIMUM OF 12" AWAY

FROM ALL CEILING APPLIANCES.

8P8C

ACS

ADA

AFF

AFG

ANSI

AV

AWG

BBC

BLDG

BMS

C

CAT6

CATV

CFCI

CL

CLG

COMM

CP

CR

CT

CU

DDC

DS

DTL

DWG

EA

EH

EF

EL

ELEC

EMT

ENT

EQUIP

ER

ES

F/UTP

FA

FDU

FMC

FO

FOC

GFCI

GRC

HD

HDPE

IAW

IMC

IP10

LA

LV

MAG

TMH

MIN

MISC

MM

MT,MTD

N/A, NA

NEC

NFPA

NTS

ON

OH

OSP

PB

PBB

PET

POE

PTZ

PVC

QTY

RCDD

RGS

RM

RMC

RX

SBB

SCH

SM

SPEC

ST

TBD

TEF

TELECOM

TIA

TP

TR

TV

TYP

UCL

UF

UG

UNO

UPS

V/D W W/ W/O

WAO

WAP

WP

• ARNEC (FEBRUARY 2020) - US ARMY RESERVE NETWORK ENTERPRISE CENTER INFRASTRUCTURE

TECHNICAL CRITERIA, W/CHANGE 3

• TECHNICAL GUIDE FOR INSTALLATION INFORMATION INFRASTRUCTURE ARCHITECTURE (JULY 2008).

• UFC 3-580-01, TELECOMMUNICATIONS INTERIOR INFRASTRUCTURE PLANNING AND DESIGN

W/CHANGE 1.

• UFC 4-021-02, ELECTRONIC SECURITY SYSTEMS W/CHANGE 1.

• TIA-568.0-E (MARCH 2020) – GENERIC TELECOMMUNICATIONS CABLING FOR CUSTOMER PREMISES.

• TIA-568.1-E (MARCH 2020) – COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD

PART 1: GENERAL REQUIREMENTS.

• TIA-568.2-D (AUGUST 2020) – BALANCED TWISTED-PAIR TELECOMMUNICATIONS CABLING AND

COMPONENTS STANDARD.

• TIA-568.3-E (SEPTEMBER 2022) OPTICAL FIBER CABLING COMPONENTS STANDARD.

• TIA-569-E (MAY 2019) – TELECOMMUNICATIONS PATHWAYS AND SPACES.

• TIA-606-D (OCTOBER 2021) – ADMINISTRATION STANDARD FOR COMMERCIAL TELECOMMUNICATIONS

INFRASTRUCTURE.

• TIA-607-D (JULY 2019) – COMMERCIAL BUILDING GROUNDING (EARTHING) AND BONDING

REQUIREMENTS FOR TELECOMMUNICATIONS.

• TIA-758-B (MARCH 2012) – CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS

INFRASTRUCTURE STANDARDS.

• T-OSP-PDC (SEPTEMBER 2021), TELECOMMUNICATIONS OUTSIDE PLANT PLANNING AND DESIGN

CRITERIA

• BICSI TDMM, 15TH EDITION (2024) – TELECOMMUNICATIONS DISTRIBUTION METHODS MANUAL.

• BICSI OSPDRM, 6TH EDITION (2018) – OUTSIDE PLANT DESIGN REFERENCE MANUAL.

T

WAP

WAP

WAP

US Army Corps of Engineers ®

F ile

P a th

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N S

IZ

E

A

N S

I D

F

IL

E N

A M

E

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

M

IC

H A

E L B

A K

E R

I N

T E

R N

A T

IO

N

A L

IN

C

A

IR

S

ID

E

D R

IV

E

M O

O N

T O

W N

S H

IP

P

A

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

B

IM

/1 L

R L C a m p P a rk s A

S T

B a rr a c k s /1

C a m p P a rk s A

S T

B a rr a c k s T

.r v t

U S

-9 A

-T -0

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S Y

M B

O L

S

S C

H E

D U

L E

S

N

O T

E S

T-001

A D

V A

N C

E D

S K

IL

L S

T R

A

IN

IN

G

B A

R R

A C

K S

P A

R K

S R

E S

E R

V E

F O

R C

E S

T R

A

IN

IN

G

A R

E A

P

C E

R T

IF

IE

D F

IN

A

L S

U B

M

IS

S

IO

N

B C

O F

F E

N D

A F

F E

R

C C

H A

R L E

S

J Z

U K

O W

S K

I

J D

O D

S O

N

F

E B

R U

A R

Y