About this file

This document is a Request for Proposal (RFP) for the Design-Bid-Build construction of a collocated Area Maintenance Support Activity (AMSA) and Vehicle Maintenance Shop (VMS) located on Camp Pendleton, CA for the U.S. Army Reserves. The project requires the construction of a 15,000 square foot AMSA and VMS facility, including site preparation, a vehicle wash rack, equipment ramps, fencing, and utility connections. The contract duration is 900 calendar days from award. The solicitation is issued by the Department of the Army Corps of Engineers Engineering District Louisville. Facilities must be designed to a minimum 40-year life and meet energy efficiency requirements. The project also requires the demolition of four existing buildings totaling 6,774 square feet. The RFP does not provide pricing terms, set-asides, or information on incumbents.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMDT #0001

Environmental Condition of Property Report

W912QR24R0015_Specs_Vol2-0001

FINAL

Roark Hall United States Army Reserve Center Oceanside, California 92058

Environmental Documentation in Support of U.S. Army Reserve Facility Construction

Contract # W912QR17D0031 Delivery Order # W912PL22F0027

Prepared for:

US Army Corps of Engineers, Los Angeles District Technical & Environmental Support Branch

645 N. Durfee Ave, South El Monte CA 91733 and

Headquarters, 63d Readiness Division Directorate of Public Works

Environmental Division 230 R.T. Jones Road

Mountain View, California 94043

Prepared by:

LRS Federal, LLC Under Subcontract to Whitetail Environmental, LLC 614 N. Main Street

Jay, Oklahoma 74346

July 2023

SUBJECT: Environmental Condition of Property (ECP) Report for the Roark Hall United States Army Reserve Center located at 21 Kraus Road, Oceanside, California 92055, dated July 2023.

To the best of my knowledge and belief, based upon this ECP report and facts presented to me, the conditions of the property described within this document are true at this time, and this report is in general accordance with the Department of Defense requirements for completion of an ECP report.

RONALD F. HUGHES Date Colonel, USAR Regional Engineer and Director of Public Works 63d Readiness Division United States Army Reserve

Final

Roark Hall United States Army Reserve Center Oceanside, CA

PAGE i

TABLE OF CONTENTS

EXECUTIVE SUMMARY ........................................................................................... ES-1

1.0 INTRODUCTION

2.0 PROPERTY DESCRIPTION

3.0 PROPERTY HISTORY

4.0 ADJACENT PROPERTIES

5.0 REVIEW OF REGULATORY INFORMATION

6.0 ENVIRONMENTAL CONDITION OVERVIEW

7.0 CONCLUSIONS

8.0 REFERENCES

Roark Hall United States Army Reserve Center

PAGE ii

LIST OF APPENDICES

A Maps and/or Historical Aerial Photographs B Photographs C Interview Documentation D Chain of Title Documentation E Previous Reports/Supporting Documentation F Regulatory Database Search Reports G Resume of Environmental Professional

Roark Hall United States Army Reserve Center Oceanside, CA

July 2023

PAGE iii

CERTIFICATION OF ENVIRONMENTAL PROFESSIONAL

I declare that, to the best of my professional knowledge and belief, I meet the definition of Environmental Professional as defined in §312.10 of 40 Code of Federal Regulations Part 312 and I have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the subject property.

I have performed all appropriate inquiries in conformance with the standards and practices set forth in 40 Code of Federal Regulations Part 312. All information and documentation provided accurately reflects the environmental condition of the property.

This Final Environmental Condition of Property Report is in general accordance with the U.S. Department of Defense requirements for completion of an Environmental Condition of Property Report. A copy of the Environmental Professional’s resume is provided in Appendix G.

Sara Schulkowski

18 July 2023

Date LRS Federal LLC

Roark Hall United States Army Reserve Center

PAGE iv

ABBREVIATIONS AND ACRONYMS

% Percent µg/ft2 Micrograms Per Square Foot µg/kg Micrograms Per Kilogram

ACM Asbestos-Containing Material

AMSA Area Maintenance Support Activity

AR Army Regulation

ASTs Aboveground Storage Tanks

ASTM American Society for Testing and Materials

AULs Activity and Use Limitations

CA California

CERCLA Comprehensive Environmental Response, Compensation, and Liability Act

CERS Haz Waste California Environmental Reporting System Hazardous Waste

CFR Code of Federal Regulations

CIWQ California Integrated Water Quality System

CORRACTS Corrective Action Report

DoD Department of Defense

ECHO Enforcement and Compliance History Information

ECP Environmental Condition of Property

EDR Environmental Data Resources, Inc.

EMI Emissions Inventory Data

ENF Enforcement Action Listing

FEMA Federal Emergency Management Agency

FINDS Facility Index System/Facility Registry System

FYR Five-Year Review

Hist UST Historical UST

Roark Hall United States Army Reserve Center

PAGE v

HMMD Hazardous Materials Management Division Database

HWTS Hazardous Waste Tracking System

IPaC Information for Planning and Consultation

IR Installation Restoration kg Kilograms

LUCIS Land Use Control Information System

LBP Lead-Based Paint

LQG Large Quantity Generator

LRS LRS Federal LLC

MCB Marine Corps Base

MEC Munitions and Explosives of Concern

MILCON Military Construction

NAVFAC Naval Facilities Engineering Systems Command

NESHAPS National Emission Standards for Hazardous Air Pollutants

NONGEN/NLR NonGenerators/No Longer Regulated

NPDES National Pollutant Discharge Elimination System

NPL National Priorities List

NRHP National Register of Historic Places

NWI National Wetlands Inventory

O&M Operation and Management

OWS Oil Water Separators

PCBs Polychlorinated Biphenyls pCi/L Picocuries per Liter

PFAS Per- and Polyfluoroalkyl Substances

PRP Potentially Responsible Parties

Property Patton Hall United States Army Reserve Center

RAATS RCRA Administrative Action Tracking System

Roark Hall United States Army Reserve Center

PAGE vi

REC Recognized Environmental Condition

Response State Response Sites

RCRA Resource Conservation and Recovery Act

RD Readiness Division

RODS Records of Decision

RR Rural Residential

SEMS Superfund Enterprise Management System sf Square Feet

SQG Small Quantity Generators

SWEEPS UST Statewide Environmental Evaluation and Planning System UST

TP Target Property

TSDF Treatment, Storage and Disposal Facilities

U.S. United States

USACE United States Army Corp of Engineers

USARC United States Army Reserve Center

USC United States Code

USDA United States Department of Agriculture

US ENG CONTROLS Engineering Controls Sites List

USEPA United States Environmental Protection Agency

USFWS United States Fish and Wildlife Service

USGS United States Geological Survey

US INST CONTROLS Institutional Controls Sites List

USTs Underground Storage Tanks

UXO Unexploded Ordnance

VMS Vehicle Maintenance Shop

WDS Waste Discharge System

Roark Hall United States Army Reserve Center

PAGE vii

WMUDS/SWAT Waste Management Unit Database System/Solid Waste Assessment Test

WT% Percent Weight

Roark Hall United States Army Reserve Center

PAGE ES-1

EXECUTIVE SUMMARY

LRS Federal, LLC (LRS), under subcontract to Whitetail Environmental, LLC was authorized to prepare an Environmental Condition of Property (ECP) Report for the Roark Hall United States Army Reserve Center (USARC), hereafter referred to as the “Property”.

The Property is located at 21 Kraus Road, Oceanside, California (CA) 92055. The purpose of this ECP is to determine the environmental condition of the Property prior to the proposed construction of the new Area Maintenance Support Activity (AMSA)/Vehicle Maintenance Shop (VMS) and demolition of four existing buildings.

The Property is located at the southernmost portion of Marine Corps Base (MCB) - Camp Pendleton. MCB - Camp Pendleton was established in the 1940s and is the largest MCB in the country. A Host-Tenant agreement was created in 1976 in which MCB - Camp Pendleton (Host) provided land to the Army (Tenant) for the purposes of a Reserve Center. MCB - Camp Pendleton holds the land on its records and the Army is to hold the buildings on its records.

The Property includes approximately 11.38 acres of land improved with four buildings (Army Reserve Center Building – Roark Hall, Army Reserve Vehicle Maintenance Shop, Oil Storage Building, and Hazardous Material Storage Building), two mobile office trailers, numerous Conex storage containers, paved parking areas, and landscaped areas with trees and scrubs. The Property is bordered by MCB - Camp Pendleton to the north, east, and west and the Oceanside Yacht Club and Harbor to the south. The United States (U.S.) Army Reserve 63d Readiness Division (RD) was observed during the site inspections conducted on 16 March 2023 to currently occupy the Property. The Property is relatively flat with a ground surface elevation of 17 feet above mean sea level.

The Property is used by the U.S. Army Reserve 63d RD for administrative services, classroom training, area maintenance support, and vehicle maintenance. The U.S. Army Reserve 63d RD is proposing to construct a 10,853 square feet AMSA/VMS on the western portion of the Property. The proposed AMSA/VMS will include a vehicle wash rack/platform, bi-level equipment loading ramp, overhead crane, and accessibility for the disabled. The contractor performing demolition work at the Property will be responsible for complying with all necessary regulations. Prior to demolition, a Demolition Plan will be prepared and approved by the Contracting Officer.1

This ECP Report was prepared in conformance with 42 United States Code § 9620(h), Army Regulation (AR) 200-1 (13 December 2007) and in general conformance with the American Society for Testing and Materials (ASTM) Designation D6008-96 (2014), 1 As required by Unified Facilities Guide Specifications, Section 02 41 00: Demolition and Deconstruction.

Roark Hall United States Army Reserve Center

PAGE ES-2

Standard Practice for Conducting Environmental Baseline Survey and ASTM D5746-98 (2016), Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities.

RECOGNIZED ENVIRONMENTAL CONDITIONS

A Recognized Environmental Condition (REC) is defined by ASTM D5746-98 (2016) as the presence or likely presence of hazardous substances or petroleum products on any DoD real property under conditions that indicate an existing release, a past release, or the material threat of a release of any hazardous substances or petroleum products into structures on the property or into the ground, groundwater, or surface water of the property. The term includes hazardous substances or petroleum products even under conditions in compliance with laws. The term is not intended to include de minimus conditions that generally do not present a material risk of harm to the public health or environment and that generally would not be the subject of an enforcement action if brought to the attention of appropriate governmental agencies.

There were no RECs identified for the Property. Table E-1 provides a Project Environmental Overview of conditions at the Property. This table provides a brief description of environmental conditions that were evaluated during the ECP process.

Detailed information associated with this overview is provided in the remaining portion of the document in the designated Section number identified.

Other Environmental Conditions Fuel spills were reported and documented at the Property on 10 March 2001 and 2 June 2005. Approximately 100 gallons and 50 gallons of fuel were released at the Property on 10 March 2001 and 2 June 2005, respectively. All fuel spilled was recovered and impacted soil was transported offsite for disposal. An interview conducted as part of this ECP indicated that a small oil spill occurred at the Property during the summer of 2022. No further information was provided regarding the spill or quantity. Therefore, the spills/releases are not considered a REC. Due to the relatively small quantities, full recovery of fuel, and removal of impacted soil from the site, the spills/releases are considered de minimis conditions and are not considered RECs.

Contamination was identified at several facilities within the recommended minimum search distances of the Property. Violations were reported regarding the failure to clean up a spill/release of hazardous material and the disposal or causing of the disposal of hazardous waste to an unauthorized point (ground, storm drain, sewer system, trash, or air) at the Oceanside Yacht Club and Harbor located adjacent and south of the Property.

This facility is located downgradient, across the North Harbor (which may serve as a hydraulic barrier). Due to the hydraulic gradient and potential hydraulic barrier separating

Roark Hall United States Army Reserve Center

PAGE ES-3

the Oceanside Yacht Club and Harbor from the Property, the spills/releases are not considered a REC.

Soil contamination was reported at two buildings (Buildings 210533 and 21453) associated with MCB – Camp Pendleton due to underground storage tank (UST) leaks.

These buildings are located north of the Property. Soil contamination was remediated at these buildings and the site status is listed as “Complete – Case Closed”. Due to the closure status and completed remediation activities, the spills/releases are not considered a REC.

A former firing/artillery range associated with MCB – Camp Pendleton was located approximately one mile south of the Property. The Cleanup Status is listed as No Further Action. Therefore, the historical presence of a firing/artillery range located approximately one mile south of the Property is not considered a REC.

Roark Hall United States Army Reserve Center

PAGE ES-4

TABLE E-1. PROJECT ENVIRONMENTAL OVERVIEW

No. CATEGORY Comment

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

STORAGE

Hazardous Substance

Underground Storage Tank (UST)

Storage

No USTs were observed during the site reconnaissance. No 2.2.3.4

2 Exterior Hazardous Substance Storage

The Property is identified as a RCRA Small Quantity Generators (SQG) (generate between 100 [kg] and 1,000 kg of hazardous waste during any calendar month). Small quantity hazardous waste managed at the Property include ignitable waste, corrosive waste, cadmium, lead, mercury, and benzene.

No 3.3.1

3 Interior Hazardous Substance Storage

The Property is identified as a RCRA SQG (generate between 100 kg and 1,000 kg of hazardous waste during any calendar month).

Small quantity hazardous waste managed at the Property include ignitable waste, corrosive waste, cadmium, lead, mercury, and benzene.

No 3.3.1

4 Petroleum UST Storage

No USTs were observed during the site reconnaissance. No 2.2.3.4

5 Exterior Petroleum Storage

It is presumed that petroleum has been used and stored at the Property since the construction of the Army Reserve Vehicle Maintenance Shop in 1972 and the Oil Storage Building later in 1996. The site reconnaissance conducted on 16 March 2023 identified the use and storage of petroleum including lubricating oil, used oil, and transmission fluid.

No 3.4.1

6 Interior Petroleum Substance Storage

It is presumed that petroleum has been used and stored at the Property since the construction of the Army Reserve Vehicle Maintenance Shop in 1972 and the Oil Storage Building later in 1996. The site reconnaissance conducted on 16 March 2023 identified the use and storage of petroleum

No 3.4.1

Roark Hall United States Army Reserve Center

PAGE ES-5

No. CATEGORY Comment

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

including lubricating oil, used oil, and transmission fluid.

7 Radiological Material Storage

There is no evidence to suggest that any radiological commodities were ever improperly managed at the Property, or that any radionuclide were ever released.

No 6.2.5

RELEASES

8 Hazardous Substance Release

No evidence from the regulatory database, previous reports, interview, or site reconnaissance was identified concerning the disposal or release of hazardous material at the Property.

No 3.3.2

9 Petroleum Releases

Fuel spills were reported and documented at the Property on 10 March 2001 and 2 June 2005. Approximately 100 gallons and 50 gallons of fuel were released at the Property on 10 March 2001 and 2 June 2005, respectively. All fuel spilled was recovered and impacted soil was transported offsite for disposal. An interview conducted as part of this ECP indicated that a small oil spill occurred at the Property during the summer of 2022. No further information was provided regarding the spill or quantity.

Yes 3.4.2

10 Radiological Material Release

There is no evidence to suggest that any radiological commodities were ever improperly managed at the Property, or that any radionuclide were ever released.

No 6.2.5

11 Surrounding Properties

Contamination was identified at several facilities within the recommended minimum search distances of the Property.

Violations were reported regarding the failure to clean up a spill/release of hazardous material and the disposal or causing the disposal of hazardous waste to an unauthorized point (ground, storm drain, sewer system, trash, or air) at the Oceanside Yacht Club and Harbor located south of the Property. This facility is located downgradient, No 4.0

Roark Hall United States Army Reserve Center

PAGE ES-6

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

across the North Harbor (which may serve as a hydraulic barrier). Therefore, this facility appears to pose a low risk to the Property.

Soil contamination was reported at two buildings (Buildings 210533 and 21453) associated with MCB – Camp Pendleton due to UST leaks. These buildings are located north of the Property. Soil contamination was remediated at these buildings and the site status is listed as “Complete – Case Closed”.

Therefore, these facilities appear to pose a low risk to the Property.

A former firing/artillery range associated with MCB – Camp Pendleton was located approximately one mile south of the Property.

The Cleanup Status is listed as No Further Action. Therefore, this facility appears to pose a low risk to the Property.

OTHER PROPERTY CONDITIONS

12 Munitions & Explosives

A former indoor firing range was located within the Army Reserve Center (Roark Hall).

The former indoor firing range was converted into office space in approximately 1996.

Clean-up/decontamination activities, including the removal of a bullet stop steel plate, sand and fiberglass insulation behind the steel plate, acoustic ceiling tiles and grid, and fluorescent light fixtures, were conducted at the former indoor firing range in 2006.

Confirmation sampling confirmed that the cleanup criteria had been achieved for the entire former indoor firing range and that the former indoor firing range is clear for future adult use.

No 6.2.3

13 Asbestos Containing Materials

A building survey was completed at the Army Reserve Vehicle Maintenance Shop at the Property in 1996. The building survey identified suspect asbestos-containing material (ACM) within the exterior stucco, fire doors, and electrical wiring. According to the

No 6.2.1

Roark Hall United States Army Reserve Center

PAGE ES-7

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

Asbestos Operation and Management (O&M) Plan, ACM within the exterior stucco was classified as nonfriable. These materials were not sampled but should be assumed to contain asbestos until tested.

ACM sampling was conducted at the Army Reserve Vehicle Maintenance Shop (VMS) at the Property in 2003. ACM sampling concluded that the black rolled roofing felts, gray roofing mastic, gray window putty, white 12-inch by 12-inch floor tiles and associated black mastic, and brown glue associated with 4" cove base contain asbestos. According to the Asbestos O&M Plan, the friability of ACMs identified in the VMS is unknown.

ACM sampling was conducted for brown mastics adhering to the fiberglass panels behind steel plates at the former indoor firing range at the Property in 2006. ACM was not detected in the samples collected from the former indoor firing range at the Property. This appears to be the extent of ACM sampling at the old firing range.

The Army Reserve Center Building (Roark Hall) and Hazardous Material Storage Building were constructed in 1972. Therefore, ACM is likely present within these buildings.

The Oil Storage Building was constructed in 1996; therefore, ACM is not likely present.

14 Lead-Based Paint

Lead-based paint (LBP) sampling was conducted at the Army Reserve Vehicle Maintenance Shop at the Property in 2003.

Multiple surfaces were found to be lead based.

Lead sampling was conducted at the former indoor firing range at the Property in March 2006. Lead contaminated dust (greater than or equal to 50 micrograms per kilogram [µg/ft2] for interior floor surfaces, 250 µg/ft2 for interior horizontal window surfaces, and 800 µg/ft2 for exterior floor and horizontal window surfaces)

No 6.2.2

Roark Hall United States Army Reserve Center

PAGE ES-8

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

was detected at concentrations ranging from below the detection limit to 17,000 µg/ft2.

A follow-up industrial hygiene survey was conducted at the former indoor firing range at the Property in April 2006. Lead contaminated dust (greater than or equal to 50 µg/ft2 for interior floor surfaces, 250 µg/ft2 for interior horizontal window surfaces, and 800 µg/ft2 for exterior floor and horizontal window surfaces) was detected at concentrations ranging from below the detection limit to 580 µg/ft2. Bulk samples obtained from ceiling tiles, fiberglass insulation, and duct wrap were below the detection limit. However, LBP (greater than or equal to 0.5 percent weight [WT%]) was detected in bulk samples obtained from the brown paint on the steel truss. The sample concentration of the brown paint on the steel truss was 0.99 WT%.

Additional sampling was conducted at the former indoor firing range at the Property in November 2006. Lead contaminated dust (greater than or equal to 50 µg/ft2 for interior floor surfaces, 250 µg/ft2 for interior horizontal window surfaces, and 800 µg/ft2 for exterior floor and horizontal window surfaces) was detected at concentrations ranging from below the detection limit to 1,300 µg/ft2.

A Lead Dust-Wipe Clearance Inspection was conducted at the former indoor firing range at the Property in December 2006. The Department of the Army’s Interim Guidance for the Lead Cleanups at Indoor Firing Ranges established the concentration of 200 µg/ft2 as the threshold limit. Sample concentrations ranged from below the detection limit to 130 µg/ft2. Lead contaminated dust was detected below the 200 µg/ft2 threshold limit at the former indoor firing range at the Property.

Therefore, the cleanup criteria had been achieved for the entire former indoor firing

Roark Hall United States Army Reserve Center

PAGE ES-9

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

range. The Department of the Army confirmed that lead abatement activities were performed in accordance with the Interim Guidance for the Lead Cleanups at Indoor Firing Ranges and as such clears the former indoor firing range for future adult use.

The Army Reserve Center Building (Roark Hall), Army Reserve Vehicle Maintenance Shop, and Hazardous Material Storage Building were constructed in 1972. Therefore, LBP is likely present within these buildings.

The Oil Storage Building was constructed in 1996; therefore, LBP is not likely present.

15 PCB Equipment

No documentation could be found on polychlorinated biphenyls (PCBs); however, window putty is known to contain PCBs and should be assumed to be PCB-containing unless tested. Pole mounted transformers are located around the Property. The transformers are assumed to be owned by MCB – Camp Pendleton. There were no PCB labels on the transformers. The age of the transformers are unknown. According to the United States Environmental Protection Agency’s (USEPA) PCB Question and Answer Manual, transformers must be assumed to be PCB-containing if the date of manufacture is unknown. It is also possible that PCB-containing fluorescent light ballasts exist at the Property.

No 2.2.3.15, 6.2.4

16 Radon

Radon concentrations in San Diego County, CA average 0.677 picocuries per liter (pCi/L) on the first floor living area and 0.400 pCi/L on the second floor living area which are below the 4.0 pCi/L action level established by USEPA. Radon concentrations in basements were not reported for San Diego County, CA.

There are no records indicating that radon testing has occurred at the Property.

No 6.2.6

17 100-Year Floodplain A review of the Federal Emergency Management Agency Flood Insurance Rate No 2.4

Roark Hall United States Army Reserve Center

PAGE ES-10

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

Map of San Diego County, CA (Flood Plain Panel Number 06073C0734J) indicates that the Property is located in Zone X, an area of minimal flood hazard.

18 Historical Land Use

The Property is located at the southernmost portion of MCB - Camp Pendleton. MCB - Camp Pendleton was established in the 1940s and is the largest MCB in the country.

Based on a review of aerial photographs and topographic maps, the Property appears to be undeveloped land until approximately 1975 when the Army Reserve Center (Roark Hall) is first depicted. The Property is used for administrative services, classroom training, area maintenance support, and vehicle maintenance.

No 3.2

19 Coastal Zone Management

The Property is located within a Coastal Zone and is subject to the Coastal Zone Management Act of 1972.

No 2.6

20 Wetlands

Based on a review of the National Wetlands Inventory Map (Overview Map – 7343528.2S in the EDR Report) and National Wetlands Inventory Wetlands Mapper, there are no wetlands identified at the Property. The closest surface water features to the Property is a boat harbor, the San Luis Rey River, the Del Mar Boat Basin (Camp Pendleton Boat Basin), and Pacific Ocean located immediately south, approximately 0.25 miles south, approximately 0.13 miles north, and approximately 0.25 miles west of the Property, respectively.

No 2.5

21 Natural Resources

Several species including mammals, birds, fishes, crustaceans, and flowering plants were identified as a threatened or endangered species possibly being present in in the vicinity of the Property. According to the Information for Planning and Consultation website, the identified threatened and

No 2.7.1

Roark Hall United States Army Reserve Center

PAGE ES-11

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

endangered species do not have designated critical habitats at the Property. There are no suitable habitats for the identified threatened and endangered species at the Property and the Property has been developed. Therefore, it is presumed that the aforementioned threatened and endangered species are not present at the Property.

22 Cultural Resources

A Final Historic Buildings and Structures Survey and Evaluation was conducted at MCB – Camp Pendleton in February 2016.

The survey concluded the following:

• Las Flores Adobe (a National Historic

Landmark) and the Santa Margarita Ranch House are properties significant for their pre-military history and are listed in the National Register of Historic Places

(NRHP).

• Buildings 1133 and 51811 are recommended as eligible for the NRHP.

A Cultural Resource Evaluation was prepared for the Property in 2022. The following recommendations were provided within the Cultural Resource Evaluation:

• The archaeological sensitivity of the

Property is low. No archaeological sites have been recorded within the Property or within a quarter mile radius. Therefore, archaeological surveying or monitoring is not recommended at the Property prior to ground disturbing activities.

• The architectural sensitivity of the Property is low. The Army Reserve Center Building (Roark Hall), Army Reserve Vehicle Maintenance Shop, and Hazardous Material Storage Building at the Property were constructed in 1972 and determined to not be eligible for listing in NRHP. The State Historic Preservation Office concurred with the aforementioned assessment of the three buildings. The Oil

No 2.7.2

Roark Hall United States Army Reserve Center

PAGE ES-12

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

Storage Building was constructed in 1990 and also determined to not be eligible for listing in NRHP as it is less than 45 years old. Therefore, no additional building evaluations are needed for the Property until the Oil Storage Building becomes 45 years old.

• Given the low sensitivity for archaeological resources at the Property, intensive pedestrian or shovel testing survey and/or archaeological monitoring is not recommended prior to or during ground disturbing activities.

• Tribal consultation should be conducted to determine if traditional cultural properties/places exist within the Property or its vicinity and to determine the tribes’ interest in being contacted regarding future undertakings.

Three buildings (P-37-037902, P-37-037908, and P-37-037914) within a quarter mile of Property were identified as historic; however, they determined to not be eligible for listing in

NRHP.

23 Other Special Resources

There are no other special resources associated with the Property. No 2.7.1, 2.7.2

ADJACENT PROPERTIES

24 Petroleum Release

Violations were reported regarding the failure to clean up a spill/release of hazardous material and the disposal or causing the disposal of hazardous waste to an unauthorized point (ground, storm drain, sewer system, trash, or air) at the Oceanside Yacht Club and Harbor located adjacent and south of Property. This facility is located downgradient, across the North Harbor (which may serve as a hydraulic barrier). Therefore, this facility appears to pose a low risk to the Property.

No 4.0

Roark Hall United States Army Reserve Center

PAGE ES-13

Affect Community

Environmental Response Facilitation

Act (CERFA) Category?

Section No.

25 Hazardous Substance Release

Violations were reported regarding the failure to clean up a spill/release of hazardous material and the disposal or causing the disposal of hazardous waste to an unauthorized point (ground, storm drain, sewer system, trash, or air) at the Oceanside Yacht Club and Harbor located adjacent and south of Property. This facility is located downgradient, across the North Harbor (which may serve as a hydraulic barrier). Therefore, this facility appears to pose a low risk to the Property.

No 4.0

In accordance with ASTM Designation D5746-98 (2016), Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities, it is recommended that the Property be classified as Type 2, defined as:

An area or parcel of real property where only the release or disposal of petroleum products or their derivatives has occurred.

The Type 2 classification was selected based on the fact that fuel spills were reported and documented at the Property on 10 March 2001 and 2 June 2005. Approximately 100 gallons and 50 gallons of fuel were released at the Property on 10 March 2001 and 2 June 2005, respectively. All fuel spilled was recovered and impacted soil was transported offsite for disposal. An interview conducted as part of this ECP indicated that a small oil spill occurred at the Property during the summer of 2022. No further information was provided regarding the spill or quantity.

In accordance with AR 200-1 (2007), Environmental Protection and Enhancement, it is recommended that the Property be classified as Category I, defined as:

There is no reason to expect contamination will be encountered during the construction.

The above is only a recommendation. In accordance with §15-5.e of AR 200-1, the Garrison Commander (or equivalent) is responsible for determining the appropriate ECP category for a property being transferred based on the results of the ECP Report and actions taken to address contamination.

Roark Hall United States Army Reserve Center

1.0 INTRODUCTION

LRS Federal, LLC (LRS), under subcontract to Whitetail Environmental, LLC was authorized to prepare an Environmental Condition of Property (ECP) Report for the Roark Hall United States Army Reserve Center (USARC). The facility is located at 21 Kraus Road, Oceanside, California (CA) 92055 in San Diego County, hereafter referred to as the “Property” (Appendix A, Figure 1 and Figure 2). In support of the ECP Report, a visual reconnaissance of the Property was conducted on 16 March 2023. The purpose of the visit was to perform a site reconnaissance and obtain information indicating the environmental condition of the Property required for the proposed construction of the Area Maintenance Support Activity (AMSA)/Vehicle Maintenance Shop (VMS).

1.1 PURPOSE OF ENVIRONMENTAL CONDITION OF PROPERTY REPORT

The primary purposes of the ECP Report include the following:

• Support environmental due diligence;

• Support the site selection and site characterization for a military construction project where the Property has been under the jurisdiction, custody, and control of the United States Army Reserve;

• Provide the public with information relative to the environmental condition of the Property; and,

• Provide information about completed remedial and corrective actions at the Property.

The ECP Report contains the information required to comply with the provisions of 40 Code of Federal Regulations (CFR) Part 373, which require that a notice accompany contracts for the sale of, and deeds entered into, for the transfer of federal property on which any hazardous substance was stored, released or disposed. The Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), Section 120(h) stipulates that a notice is required if certain quantities of designated hazardous substances have been stored on the property for one year or more – specifically, quantities exceeding 1,000 kilograms (kg) or the reportable quantity, whichever is greater, of the substances specified in 40 CFR 302.4 or one kg of acutely hazardous waste as defined in 40 CFR 261.30. A notice is also required if hazardous substances have been disposed of or released on the property in an amount greater than or equal to the reportable quantity. United States (U.S.) Army Regulation (AR) 200-1 requires that the ECP Report address asbestos, lead-based paint (LBP), radon and other substances potentially hazardous to human health.

Roark Hall United States Army Reserve Center

1.2 SCOPE OF SERVICES

The ECP scope of services for the Property located at 21 Kraus Road, Oceanside, CA 92055 includes the following activities.

• Search and review of aerial photographs that may reflect prior uses of the real property and that are reasonably obtainable through state or local government agencies (Appendix A).

• Conduct and obtain photographic documentation of a visual inspection of the Property and any buildings, structures, equipment, pipe, pipeline, or other improvements on the Property, and a physical inspection of adjacent properties, to the extent permitted by owners or operators of such properties (Appendix B).

• Detailed search and review of chain of title and lease information (Appendix D).

• Detailed search and review of federal government records in the possession of the Department of Defense (DoD) components, regulatory agencies, and other involved federal agencies, including but not limited to available maps, permits, surveys, inventories, management plans, reports, reviews, and any prior ECP, Environmental Baseline Survey, and Environmental Site Assessment (Appendix E).

• Search and review of reasonably available standard federal, state, and local government records pertaining to the Property, including available maps (Appendix F).

• Search and review of reasonably obtainable standard private and federal, state, and local government records of each adjacent facility where there has been a release of any hazardous substance or any petroleum product or its derivatives and which is likely to cause or contribute to a release or threatened release of any hazardous substance or any petroleum product or its derivatives on the Property (Appendix F).

• Interviews with current and former personnel involved in operations on the Property (Appendix C).

• Identification of sources of contamination on the Property and on adjacent properties which could migrate to the Property during the U.S. Army ownership.

• Identification of ongoing response actions or actions that have been taken at or adjacent to the Property.

• Identification and description of the presence of protected species and cultural resources.

• Identification of the presence of other regulated materials or conditions, including threatened and endangered species, floodplains, pesticides, LBP, historical and

Roark Hall United States Army Reserve Center archeological resources, Native American human remains and funerary objects, equipment containing polychlorinated biphenyls (PCB), radon, unexploded ordnance (UXO) or munitions and explosives of concern (MEC), wetlands, coastal zone area restrictions, the presence of coral reef ecosystems, essential fish habitat, marine mammals, and past or current activities involving the use of radiological substances or materials.

• Identification of environmental permits, radioactive materials licenses or permits, and Resource Conservation and Recovery Act (RCRA) generator status.

This ECP adheres to 42 United States Code (USC) § 9620(h), AR 200-1 (13 December 2007), DoD 4165.66-M (1 March 2006), and follows the American Society for Testing and Materials (ASTM) D5746-98 (2016), Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities as a guideline when not inconsistent with U.S. Army regulations and other applicable U.S.

Army guidance.

This ECP covers the approximate 11.38-acre Property located at 21 Kraus Road, Oceanside, CA 92055 in San Diego County. This ECP recommends classification of the Property into one of seven DoD Environmental ECP categories as defined by the ASTM Designation D5746-98 (2016), Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities. The property classification categories are as follows:

• ECP Area Type 1 – An area or parcel of real property where no release, or disposal of hazardous substances or petroleum products or their derivatives has occurred (including no migration of these substances from adjacent properties).

• ECP Area Type 2 – Where only the release or disposal of petroleum products or their derivatives has occurred.

• ECP Area Type 3 – An area or parcel of real property where release, disposal, or migration, or some combination thereof, of hazardous substances has occurred, but at concentrations that do not require a removal or remedial action.

• ECP Area Type 4 – An area or parcel of real property where release, disposal, or migration, or some combination thereof, of hazardous substances has occurred, and all remedial actions necessary to protect human health and the environment have been taken.

• ECP Area Type 5 – An area or parcel of real property where release, disposal, or migration, or some combination thereof, of hazardous substances has occurred, and removal or remedial actions, or both, are under way, but all required actions have not yet been taken.

Roark Hall United States Army Reserve Center

• ECP Area Type 6 – An area or parcel of real property where release, disposal, or migration, or some combination thereof, of hazardous substances has occurred, but required response actions have not yet been initiated.

• ECP Area Type 7 – An area or parcel of real property that is unevaluated or requires additional evaluation.

Additionally, this ECP recommends classification of the Property into one of three Military Construction (MILCON) categories as defined by AR 200-1 (2007), Environmental Protection and Enhancement. The property classification categories are as follows:

• Category I – There is no reason to expect contamination will be encountered during the construction.

• Category II – There is no known contamination, there remains some potential that contamination may be encountered during construction.

• Category III – The site is known to be contaminated or there is strong suspicion contamination will be encountered during construction.

1.3 ASSUMPTIONS AND LIMITATIONS

The information obtained from individuals interviewed was considered to be accurate unless reasonable inquiries indicated otherwise. Conditions observed were considered representative of similar areas that were not accessible unless otherwise indicated. This ECP Report presents a summary of reasonably ascertainable information on the environmental conditions of, and concerns relative to, the land, facilities, and real property assets at the Property. Its findings are based on a record search of publicly-available documents, a thorough review of reasonably ascertainable documents, a site reconnaissance of the Property conducted on 16 March 2023, and interviews with personnel knowledgeable about the Property and its history. Existing environmental investigations and reports and historical documents were reviewed in support of this ECP.

Information obtained from these other sources is reflected within this report by reference.

All Property buildings and structures were visually inspected during the site reconnaissance. However, a 100 percent (%) visual reconnaissance of every single interior space within each building (e.g., attics, crawl spaces, etc.) was not practical due to accessibility restrictions.

This report has been prepared in compliance with ASTM D5746-98 (2016), Standard Classification of Environmental Condition of Property Area Types for Defense Base Closure and Realignment Facilities. In preparing this report, LRS has relied on certain information provided by federal, state, and local officials and other parties referenced therein, and on information contained in the files of governmental agencies, that were reasonably ascertainable at the time of this assessment. Although there may have been some degree of overlap in the information provided by these various sources, an attempt

Roark Hall United States Army Reserve Center to independently verify the accuracy or completeness of all information reviewed or received during the course of this site assessment was not conducted. Observations were made of the Property and of the structures on the Property as indicated in this report.

Roark Hall United States Army Reserve Center

2.0 PROPERTY DESCRIPTION

The Property is located at the southernmost portion of Marine Corps Base (MCB) - Camp Pendleton and is comprised of approximately 11.38 acres (Appendix A, Figure 2). MCB - Camp Pendleton was established in the 1940s and is the largest MCB in the country. A Host-Tenant agreement was created in 1976 in which MCB - Camp Pendleton (Host) provided land to the Army (Tenant) for the purposes of a Reserve Center. MCB - Camp Pendleton holds the land on its records and the Army is to hold the buildings on its records.

The Property is used by the U.S. Army Reserve 63d Readiness Division (RD) for administrative services, classroom training, area maintenance support, and vehicle maintenance. The U.S. Army Reserve 63d RD is proposing to construct a 10,853 square feet (sf) AMSA/VMS on the western portion of the Property (Appendix A, Figure 3). The proposed AMSA/VMS will include a vehicle wash rack/platform, bi-level equipment loading ramp, overhead crane, and accessibility for the disabled.

2.1 PROPERTY LOCATION

FIGURE 1 IN APPENDIX A PROVIDES A GENERAL PROPERTY LOCATION MAP.

Facility Name and Address: Roark Hall USARC, 210545 B Street, Oceanside, CA 92058

Property Owner: United States of America

Date of Purchase: 1976 (Host-Tenant Agreement Created)

Current Occupants: U.S. Army Reserve

Zoning: Rural Residential (RR): Family Residential uses permitted with Group Residential, limited packing and processing, and other uses allowed by Use Permit.

County, State: San Diego, CA

United States Geological Survey (USGS) Quadrangle(s):

Oceanside, 2018, 7.5-minute

Section/Township/Range: Section 00/Township 11S/ Range 05W

Latitude/Longitude: 33° 12' 46.77'' North / 117° 23' 50.61'' West

Roark Hall United States Army Reserve Center

Legal Description: See Chain of Title in Appendix F

2.2 DESCRIPTION

2.2.1 SITE AND VICINITY CHARACTERISTICS

The Property includes approximately 11.38 acres of land improved with four buildings, two mobile office trailers, numerous Conex storage containers, paved parking areas, and landscaped areas with trees and scrubs. A Site Plan is included as Figure 2 in Appendix A. The Property is bordered by MCB - Camp Pendleton to the north, east, and west and the Oceanside Yacht Club and Harbor to the south. Figure 2 in Appendix A depicts the Property and the surrounding areas. The U.S. Army Reserve 63d RD was observed during the site inspections conducted on 16 March 2023 to currently occupy the Property.

The Property is relatively flat with a ground surface elevation of 17 feet above mean sea level. Stormwater runoff flows to the north, east, and west of the Property.

The Property is currently zoned by San Diego County as RR. RR is described as family residential uses permitted with Group Residential, limited packing and processing, and other uses allowed by Use Permit.

2.2.2 BUILDING DESCRIPTION(S)

Army Reserve Center (Roark Hall) (Building 021A2/210545)

The Army Reserve Center is a one-story, slab on-grade masonry structure (Appendix A, Figure 2). The Army Reserve Center was constructed in 1972 and contains approximately 27,150 sf of floor space primarily used for administrative and classroom purposes.

Army Reserve Vehicle Maintenance Shop (Building 021A3/210546)

The Army Reserve Vehicle Maintenance Shop is a one-story, slab on-grade masonry structure (Appendix A, Figure 2). The Army Reserve Vehicle Maintenance Shop was constructed in 1972 and contains approximately 5,374 sf of floor space.

Hazardous Material Storage Building (Building 021A8/210547)

The Hazardous Material Storage Building is a one-story, slab on-grade masonry structure (Appendix A, Figure 2). The Hazardous Material Storage Building was constructed in 1972 and contains approximately 202 sf of floor space.

Oil Storage Building (Building 021A6)

The Oil Storage Building was constructed in 1996 and contains approximately 156 sf of floor space.

Roark Hall United States Army Reserve Center

2.2.3 OTHER FACILITIES AND SITE FEATURES

2.2.3.1 MOBILE OFFICE TRAILERS

Two mobile office trailers are located near the southwest corner of the Army Reserve Vehicle Maintenance Shop. One trailer contains approximately 690 sf of floor space while the other trailer contains approximately 321 sf of floor space. Based on a review of the historical aerial photographs detailed in Section 3.2.1, it appears that the two mobile office trailers were installed around 2009.

2.2.3.2 CONEX STORAGE CONTAINERS

Numerous Conex containers are located at the Property. The Conex containers are used for the storage of various materials.

2.2.3.3 PAVED/GRAVEL PARKING AREAS

The majority of the Property consists of areas paved with either asphalt, concrete, or gravel (Appendix A, Figure 2).

2.2.3.4 UNDERGROUND STORAGE TANKS (USTS)

A visual inspection was undertaken to locate any USTs at the Property. Evidence of USTs, including vent pipes, fill pipes, concrete pads, and access ways were investigated.

No USTs were observed during the site reconnaissance.

2.2.3.5 ABOVEGROUND STORAGE TANKS (ASTs)

An approximate 280-gallon aboveground storage tank (AST) is located within the Army Reserve Vehicle Maintenance Shop (Appendix B, Photograph 32). The AST contains used oil and is pumped every other month for disposal.

2.2.3.6 VEHICLE WASH PAD AND OIL-WATER SEPARATOR

A covered vehicle wash pad and an associated oil-water separator (OWS) are located on the eastern portion of the Property near the Hazardous Material Storage Building. MCB - Camp Pendleton maintains the OWS, which discharges into a storm drain that eventually discharges into satellite lift station 7A. During the site reconnaissance, the OWS was observed to be clogged as water was pooling in the secondary containment. No oil sheen was observed on the pooling water (Appendix B, Photographs 20, 21, and 23). The OWS apparently clogs following major rain events.

Roark Hall United States Army Reserve Center

2.2.3.7 SITE WASTE AND WASTEWATER

Solid Waste

Solid waste was not observed at the Property during the site reconnaissance. However, poor housekeeping was observed on the exterior of the Property during the site reconnaissance. Various types and amounts of items were observed to be stored on the exterior of the Property including random parts, various metal and plastic containers, sand bags, wood pallets, tires, metal 55-gallon drums labeled engine oil, unlabeled plastic 55-gallon drums (Appendix B, Photographs 6-10, 13, and 17-19). The drums were stored on wood pallets and appear to be empty. The metal drums appeared to be in fair condition with rust primarily on the tops. The plastic drums appeared to be in good condition. No staining/spillage was observed around the various items stored on the exterior of the Property. These items do not appear to pose a risk to human health and/or the environment.

Sanitary Sewage

Sanitary sewage disposal is provided by MCB - Camp Pendleton.

2.2.3.8 STAINED SOIL, STAINED PAVEMENT, OR STRESSED VEGETATION

No stained or discolored soil or distressed vegetation was observed during the site reconnaissance.

2.2.3.9 LIQUID DISCHARGES

No visible evidence of liquid discharges suspected to represent an environmental concern were observed during the site reconnaissance.

2.2.3.10 POOLS OF LIQUID

Standing surface water was observed at the Property in the following locations:

• Parking lot’s median, north of the Army Reserve Center (Appendix B, Photograph 1).

• Southwest corner of the Property (Appendix B, Photograph 4).

• OWS located on the eastern portion of the Property near the Hazardous Material Storage Building (Appendix B, Photographs 21 and 22).

• East of the Army Reserve Vehicle Maintenance Shop (Appendix B, Photograph 20).

There was no visible evidence of standing water containing liquids likely to be hazardous substances or petroleum products.

Roark Hall United States Army Reserve Center

2.2.3.11 PITS, PONDS, OR LAGOONS

No pits, ponds, or lagoons were observed during the site reconnaissance.

2.2.3.12 WELLS

No onsite dry wells, irrigation wells, injection wells, observation wells, monitoring wells, recovery wells, or abandoned wells were observed during the site reconnaissance.

2.2.3.13 ONSITE FILL

No fill has been imported to…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .