W912QR24R0015_Plans-0003.pdf
PDF 2 MB Posted
- Solicitation number
- W912QR24R0015
About this file
This document is a set of plans and drawings for the construction of a 15,000 square foot collocated Area Maintenance Support Activity (AMSA) and Vehicle Maintenance Shop (VMS) facility at Camp Pendleton, CA. The project is a Design/Bid/Build contract solicited under Solicitation No. W912QR24R0015 by the U.S. Army Corps of Engineers Louisville District. Key details include:
The facility will include site work, a vehicle wash rack/platform, bi-level equipment loading ramp, fencing, and utility connections. The contract duration is 900 calendar days from award. The project has a minimum 40-year design life and must comply with energy efficiency and accessibility requirements. The plans provide architectural, structural, mechanical, and interior design details for the new facility, as well as requirements for demolishing four existing buildings totaling 6,774 square feet. A 10-ton overhead crane system is to be incorporated into the design.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X X
X X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X
8.0'
5.7
1.0
8.0
1.0
6" DIAMETER ROCK COBBLE
ENERGY DISSIPATOR
ALIGN ROCK WITH
EDGE OF CONCRETE
CONCRETE APRON
PER DETAIL L1/CS501
EXISTING AC
0" CURB PER
DETAIL A9/CS501
AC PAVEMENT PER
DETAIL L1/CS501
3' RIBBON GUTTER
PER DETAIL G10/CS501
D R
AW
N
B Y:
L.
M
ED
IN
A
D
ES
IG
N
ED
B
Y:
C
. D E
C
AS
TR
O
SU
BM
IT
TE
D B
Y:
D
. B
AR
KE
R
C H
EC
KE
D B
Y:
J.
W O
O D
R U
FF
SO
LI
C
IT
AT
IO
N N
O
C O
N
TR
AC
T
N O
PL
O
T D
AT
E:
8/ 2/
2:
:4
PM
US Army Corps of Engineers ®
SHEET ID
SI
ZE
AN
SI
D
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
D
R M
AR
TI
N L
U
TH
ER
K
IN
G
J R
P L, LO
U
IS
VI
LL
E, K Y
M
IC
H
AE
L
BA
KE
R
IN
TE
R N
AT
IO
N
AL
, I N
C
AI
R
SI
D
E D
R
IV
E M
O O
N T
O W
N
SH
IP
, P
A
C
AM
P
PE
N D
LE
TO
N , O
C
EA
N
SI
D E, C A
A R
EA
M
AI
N
TE
N
AN
C
E
SU
PP
O
R T
AC
TI
VI
TY
(A M
SA
U S-
A
IS
SU
E D
AT
E:
JA
N
U
AR
Y
A
FI
LE
N
AM
E:
U
S-
A- G
-C S5
J
AN
U
AR
Y
C
ER
TI
FI
ED
F
IN
AL
P2
FY
SI
TE
P
LA
N D
ET
AI
LS
CS504
YIELD
DO NOT
ENTER
R5-1 36" x 36"
R1-2 30" x 30" x 30"
SCALE: NTS
SIGN POST
SLOPE
CONCRETE
TO DRAIN
FINISHED GRADE (PAVED OR NON-PAVED)
2" ALUMINUM I.D. SIGN POST
SIGN PER PLAN
MOUNT SIGN SECURELY TO
POST.
3/8 " DIA. HOLES
4"
CONCRETE
1'- 0"
5'- 0"
(A
LL
S
IG
NS
3'- 0"
1"
12"
NOTE:
SET CENTER OF STOP SIGN
2'-0" BEHIND FACE OF CURB
J14SCALE:
ARROW MARKING
NOTES:
1. UTILIZE MUTCD
TYPE VI ARROW
2. PROVIDE WHITE
STRIPING
J1 NTS
8'- 0"
1'-0" GRID A=14²
T
PE
R
PL
AN
T/
1" BAR, 16" LONG
SPACED AT 12" O.C.
JOINT SEALANT PER
DETAIL L10/CS501
PANEL LENGTH
JOINT SEALANT PER
DETAIL L10/CS501TOP OF
CONCRETE
PAVEMENT
3/4"
T
PE
R
PL
AN
1.2 5 T
SCALE: NTS
THICKENED EDGE ISOLATION JOINT
SCALE: NTS
DOWELED CONSTRUCTION JOINT
E16
A16
1'-0" 3'-6"
CARPOOL
PARKING
ONLY
CARPOOL SIGN
36" x 36"
BIOFILTRATION BASIN
SCALE:
NOTES:
1. PLANTER SOIL MIX TO CONSIST OF 20% COMPOST, 60% SAND, 20% TOP SOIL (NO CLAY).
2. BASIN DIMENSIONS PER CS101.
BASIN SECTION
CS101
EXCAVATED SLOPE
12" SOIL MEDIA WITH MIN. 5 IN/HR FILTRATION RATE
DRAIN ROCK
TB PER PLANTB PER CG101
BOTTOM OF BASIN
ELEVATION PER CG101
EXISTING UNCOMPACTED SUBGRADE
NTSA1
SCALE: NTS
CURB AND GUTTERJ7
2%
6" M
IN
NOTES:
1. CONCRETE PER SPECIFICATIONS.
6" 1'-6"
6"
VA
RI
ES 10 1/2"
4 1/2"
12"
KEEP ADJACENT
GRADE 1" BELOW TOP
OF CURB MINIMUM
2" WEAKENED
PLANE JOINT
ASPHALT OR CONCRETE
PAVEMENT PER PLAN
AC SEE DETAIL L1/ CS501
CONC SEE DETAIL L5/ CS501
RADIUS = 3/8" (TYP)
RADIUS = 1/2" (TYP)
CONCRETE CURB
AND GUTTER
SCARIFY AND RECOMPACT TO
95% MAXIMUM DENSITY,
MINIMUM 12" PER ASTM D1557
LINE BASIN WIH 6"
MINIMUM ROCK
6"
GUTTER OUTLET
SCALE: NTSF1
5 2.5 5 10 15
SCALE: 1"=5'
PLAN NORTH
AM
D T
#0
-0 4-
W
2Q R
R
_P la ns -0
ARIMS: 200A Disposition: Maintain for 15 yrs after construction.
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4
A
P
F Y
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -S
.r v t
/1
/2
:2
:3
A M
S-002
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
J B
R O
C K
J D
'A N
IE
L L O
D B
A R
K E
R
L .H
Y N
A L
U S
-4 A
-S -0
STRUCTURAL STEEL
S-1 STRUCTURAL STEEL WORK IS TO BE DETAILED AND CONSTRUCTED IN
ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
"SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS" (LATEST EDITION) AND THE
“CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”.
S-2 STRUCTURAL STEEL, UNLESS NOTED OTHERWISE, TO CONFORM TO THE
REQUIREMENTS OF ASTM STANDARDS AS INDICATED ON THE STEEL MATERIAL
SCHEDULE ON DRAWING S-601.
S-3 PRIOR TO FABRICATION, THE STEEL FABRICATOR IS TO SUBMIT TO THE
CONTRACTING OFFICER FOR REVIEW THE FOLLOWING:
A. DESIGN CALCULATIONS OF STRUCTURAL STEEL CONNECTIONS, PREPARED
BY OR UNDER THE SUPERVISION OF, A PROFESSIONAL ENGINEER
REGISTERED IN THE STATE OF WHICH THE PROJECT IS CONSTRUCTED AND
BEARING THE SEAL OF THE PROFESSIONAL ENGINEER.
B. SHOP DRAWINGS SHOWING ERECTION PLANS, PIECE DRAWINGS, AND
CONNECTION DETAILS.
S-4 THE STRUCTURAL STEEL FABRICATOR, AND/OR GENERAL CONTRACTOR, MUST
VERIFY EXISTING DIMENSIONS AND CONDITIONS AT THE SITE. DISCREPANCIES
FOUND ARE TO BE REPORTED TO THE CONTRACTING OFFICER PRIOR TO
PREPARATION OF SHOP DRAWINGS. SHOP DRAWINGS ARE TO INCLUDE FIELD
MEASUREMENTS AND CONDITIONS.
S-5 STRUCTURAL STEEL FABRICATOR IS TO PROVIDE FOR VERTICAL AND HORIZONTAL
FIELD ADJUSTMENT OF SUPPORT ASSEMBLIES.
S-6 STEEL BEAMS ARE TO BE EQUALLY SPACED IN BAYS UNLESS OTHERWISE NOTED.
S-7 FABRICATE AND INSTALL BEAMS WITH NATURAL CAMBER UP UNLESS CAMBER IS
NOTED ON THE DRAWINGS.
S-8 STRUCTURAL STEEL FRAMES SHALL BE SECURELY BRACED UNTIL FLOOR SLABS,
ROOF DECKS AND SHEAR WALLS HAVE BEEN INSTALLED AND BECOME CAPABLE OF
STABILIZING THE FRAMES.
S-9 BOLTED CONNECTIONS TO BE DESIGNED AND DETAILED ACCORDING TO AISC
TABLE 10-1 OR 10-2 – DOUBLE ANGLE CONNECTIONS. THE MINIMUM DEPTH OF THE
CONNECTION MUST BE MORE THAN 67% OF THE BEAM DEPTH EXCEPT THAT BEAMS
FRAMING TO COLUMNS TO HAVE FULL DEPTH CONNECTIONS USING 3/8" MINIMUM
CONNECTION ANGLES OR PLATES. NON- COMPOSITE BEAM CONNECTIONS TO BE
DESIGNED FOR ONE HALF THE UNIFORM LOAD CAPACITY OF THE BEAM AS
TABULATED BY AISC UNLESS HIGHER LOADS ARE INDICATED ON THE DRAWINGS.
S-10 UNLESS OTHERWISE NOTED, STRUCTURAL STEEL CONNECTIONS TO BE SHOP
WELDED AND FIELD BOLTED. CONNECTIONS ARE TO BE DESIGNED AND DETAILED
IN ACCORDANCE WITH AISC STANDARD 341 “SEISMIC PROVISIONS FOR STRUCTURAL
STEEL BUILDINGS.”
A. BOLTS: 3/4" DIAMETER ASTM A 325 UNO WITH MATCHING WASHERS AND
HEAVY HEX NUTS..
B. WELDS MUST BE ¼” FILLET WELDS UNLESS NOTED OTHERWISE.
S-11 POST INSTALLED ANCHORS SHOWN ON THE DRAWINGS ARE TO BE FURNISHED AND
INSTALLED PER PROJECT SPECIFICATION 05 05 20.
S-12 SUBSTITUTION OF EXPANSION ANCHORS FOR EMBEDDED ANCHORS SHOWN ON THE
DRAWINGS WILL NOT BE PERMITTED.
S-13 WELDING TO BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY (AWS)
"STRUCTURAL WELDING CODE-ANSI/AWS D1.1/D1.1M" (LATEST EDITION). USE E70XX
ELECTRODES UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
S-14 MANUFACTURE STEEL GRATING IN ACCORDANCE WITH THE “METAL BAR GRATING
MANUAL” AS PUBLISHED BY THE NATIONAL ASSOCIATION OF ARCHITECTURAL
METAL MANUFACTURERS, LATEST EDITION.
A. ALUMINUM FOR GRATING TO CONFORM TO ASTM B 221. GRATING TO BE
TYPE AS NOTED WITH MILL FINISH, UNO.
S-15 PAINT AND PROTECTION:
A. DO NOT PAINT THE TOP FLANGE OF BEAMS TO RECEIVE COMPOSITE SHEAR
CONNECTORS.
B. EXPOSED STRUCTURAL STEEL FOR SCREEN WALLS, EQUIPMENT
PLATFORMS, LOOSE ANGLE LINTELS ETC, TO BE HOT DIPPED GALVANIZED
PER ASTM A-123
C. GALVANIZED FASTENERS AND ACCESSORIES TO BE HOT DIPPED
GALVANIZED PER ASTM A153/A153M.
D. PROVIDE MINIMUM 3” CONCRETE COVER FOR STEEL BELOW GRADE.
E. PROVIDE SEPARATION BETWEEN ALUMINUM GRATE AND STEEL BEAMS TO
PREVENT CONTACT BETWEEN DISSIMILAR METALS.
METAL BUILDING SYSTEMS
MB-1 DESIGN, FABRICATION AND ERECTION OF THE PRE-ENGINEERED METAL BUILDING
SYSTEM MUST BE SUFFICIENT TO WITHSTAND LOADS FROM WIND, SNOW, GRAVITY,
STRUCTURAL MOVEMENT, SEISMIC ACTION AND HIGH BAY MAINTENANCE AREA 10-
TON BRIDGE CRANE WITHOUT EXCEEDING ALLOWABLE STRESSES AND
MUST BE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE
FOLLOWING CODES:
A. METAL BUILDING MANUFACTURERS ASSOCIATION (MBMA) “METAL BUILDING
SYSTEMS MANUAL” (LATEST EDITION).
B. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) “SPECIFICATIONS
FOR STRUCTURAL STEEL BUILDINGS” AND STEEL DESIGN GUIDE SERIES 3:
“SERVICEABILITY DESIGN CONSIDERATIONS FOR LOW-RISE BUILDINGS”.
C. IRON AND STEEL INSTITUTE (AISI) “NORTH AMERICAN SPECIFICATION FOR
THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS” (LATEST
EDITION).
D. AMERICAN WELDING SOCIETY (AWS) “STRUCTURAL WELDING CODE STEEL
AWS D1.1/D1.1M”.
E. UNITED FACILITIES CRITERIA, UFC 3-301-01, “STRUCTURAL ENGINEERING”.
MB-2 DEFORMATIONS OF THE PRE-ENGINEERED BUILDING (INCLUDING BUT NOT LIMITED
TO LATERAL DRIFT, RACKING OF FRAMES, AND HORIZONTAL AND OR VERTICAL
DEFLECTION OF STRUCTURAL ELEMENTS, CLADDING OR OTHER SUPPORTED
ELEMENTS), IS TO BE LIMITED BY THE RECOMMENDATIONS SET FORTH IN AISC’S
STEEL DESIGN GUIDE SERIES 3: “SERVICEABILITY DESIGN CONSIDERATIONS FOR
LOW-RISE BUILDINGS,” AND AS FOLLOWS:
A. LATERAL SWAY OF MAIN FRAMES AT TOP OF MASONRY WALL H/480 or 3/4”
MAX
B. HORIZ DEFLECTION OF GIRTS SUPPORTING MASONRY WALL L/240 or 1-1/2”
MAX
C. VERTICAL DEFLECTION OF MAIN FRAME L/240 OR 6”
MAX
D. VERTICAL DEFLECTION OF PURLINS L/240 OR 1-1/2”
MAX
E. LATERAL MOVEMENT OF ELEMENTS SUPPORTING DRYWALL PARTITIONS (H=
PARTITION HT) H/240 PER UFC
3-301-01
TABLE 2-1
MB-3 WIND FORCES USED FOR COMPUTATION OF MEMBER STRESSES ARE TO BE BASED
ON THE 50-YEAR MEAN RECURRENCE INTERVAL (MRI) WIND SPEED CALCULATED
PER ASCE 7. COMPUTE DRIFT DUE TO WIND BASED ON THE 10-YEAR MEAN
RECURRENCE INTERVAL (MRI) WIND SPEED CALCULATED PER ASCE 7.
MB-4 PRIOR TO FABRICATION, CONTRACTOR IS TO SUBMIT THE FOLLOWING ITEMS TO
THE CONTRACTING OFFICER FOR REVIEW. SUBMITTED ITEMS MUST BE PREPARED
BY, OR UNDER THE SUPERVISION OF, A PROFESSIONAL ENGINEER REGISTERED IN
THE STATE THAT THE PROJECT WILL BE CONSTRUCTED AND BEAR THE SEAL OF
THAT PROFESSIONAL ENGINEER.
A. SUBMIT ERECTION DRAWINGS TO INCLUDE DETAILS SHOWING ERECTION
AND ASSEMBLY OF THE METAL BUILDING SYSTEM INCLUDING SIDE WALL,
END WALL, AND ROOF FRAMING. INCLUDE BUILDING TRANSVERSE AND
CROSS SECTIONS WITH WIND AND SEISMIC BRACING PRESENT FOR THE
BUILDING SYSTEM. ERECTION DRAWING COLUMN GRID LINES SHALL MATCH
MBI PROJECT DRAWINGS,
B. SUBMIT ANCHOR ROD PLACEMENT DRAWING TO SHOW ANCHOR ROD
LOCATIONS. INCLUDE CALCULATED FOUNDATION LOADS AT THE BASE OF
COLUMNS.
C. SUBMIT PANEL LAYOUTS ON WALLS, ROOF CANOPIES AND ROOFS. DETAILS
OF SUPPORTS ANCHORAGES AND SPECIAL CONDITIONS. INCLUDE DETAILS
OF PANEL PROFILES.
MB-5 CONTRACTOR IS TO ENGAGE AN EXPERIENCED INSTALLER TO ERECT THE PRE-
ENGINEERED METAL BUILDING WHO IS EXPERIENCED IN THE ERECTION OF METAL
BUILDINGS AND WHO IS CERTIFIED IN WRITING BY THE METAL BUILDING SYSTEM
MANUFACTURER AS QUALIFIED FOR ERECTION OF THE MANUFACTURER’S
PRODUCTS.
MB-6 FABRICATE FRAMING COMPONENTS IN THE SHOP TO THE GREATEST EXTENT
POSSIBLE. IN GENERAL, SHOP WELD AND FIELD BOLT CONNECTIONS.
MB-7 EXERCISE CARE IN DELIVERING, UNLOADING, STORING AND ERECTING BUILDING
MEMBERS, WALL AND ROOF COVERING PANELS AND OTHER BUILDING
COMPONENTS TO PREVENT BENDING, WARPING, TWISTING AND SURFACE DAMAGE.
MB-8 ERECT FRAMING TRUE TO LINE, LEVEL AND PLUMB. LEVEL BASE PLATES TO A TRUE
PLANE WITH FULL BEARING TO SUPPORTING STRUCTURE; USE A NON-SHRINKING
GROUT TO OBTAIN UNIFORM BEARING AND TO MAINTAIN A LEVEL BASE LINE
ELEVATION.
MB-9 PROVIDE LATERAL LOAD RESISTING SYSTEMS TO RESIST THE INDICATED WIND AND
SEISMIC LOADS IN ROOF AND SIDE WALLS. WHERE OVERHEAD DOORS INTERFERE
WITH DIAGONAL BRACING, PROVIDE STRUCTURAL WIND FRAMES. PROVIDE SAG
RODS TO MAINTAIN VERTICAL ALIGNMENT OF WALL GIRTS. REFERENCE THE PLAN
DRAWINGS FOR PERIMETER BRACING AND FRAME LOCATIONS.
MB-10 PROVIDE FRAMED DOOR AND WINDOW OPENINGS OF DESIGN AND SIZE TO
ACCOMMODATE FINISHED UNITS AND TO TRANSMIT ALL LOADS TO THE BUILDING
STRUCTURE.
MB-11 DESIGN THE PRE ENGINEERED METAL BUILDING TO PROVIDE LATERAL SUPPORT OF
THE MASONRY WALLS AT THE ROOF AND INTERMEDIATE LOCATIONS SPECIFIED ON
THE DRAWINGS. LATERAL SUPPORT MUST BE IN THE FORM OF A GIRT, SPANDREL
BEAM, OR OTHER APPROVED MEANS. THE MASONRY WALLS MUST BE BOLTED TO
THE LATERAL SUPPORTS. THE LATERAL SUPPORTS MUST BE CLIPPED TO THE MAIN
FRAME COLUMNS WITH VERTICALLY SLOTTED CONNECTIONS.
METAL BUILDING SYSTEMS CONT
MB-12 THE FOUNDATION DESIGN ON THESE CONTRACT DRAWINGS IS PRELIMINARY AND
BASED UPON ASSUMED COLUMN BASE REACTIONS CALCULATED BY A STRUCTURAL
ENGINEER. THESE REACTIONS ARE INDICATED IN A TABLE ON DRAWING S-602.
UPON FINAL BUILDING DESIGN, THE ACTUAL COLUMN BASE REACTIONS ARE TO BE
COMPARED TO THE PRELIMINARY FOUNDATION DESIGN LOADS BY THE GENERAL
CONTRACTOR. IF THE ACTUAL REACTIONS EXCEED THE PRELIMINARY DESIGN
LOADS, THE FOUNDATION DESIGN PROVIDED IS VOID AND A REGISTERED
PROFESSIONAL ENGINEER MUST BE EMPLOYED BY THE GENERAL CONTRACTOR TO
COMPLETE A FOUNDATION DESIGN BASED UPON THE ACTUAL REACTIONS.
A. COLUMN BASES ARE TO BE PINNED. FIXED BASES ARE NOT PERMITTED.
B. ANCHOR ROD DIAMETERS, AND SPACINGS ARE TO BE PROVIDED FOR BY THE
PEMB MANUFACTURER AND COMPLY WITH THE FOOTING AND DETAILS
REFERENCED.
MB-13 THE GENERAL CONTRACTOR IS TO COORDINATE WITH THE PEMB MANUFACTURER
AND MECHANICAL SUBCONTRACTORS TO PROVIDE SUPPORT FOR SUSPENDED
EQUIPMENT, PIPING, DUCTWORK AND UTILITIES IDENTIFIED ON THESE STRUCTURAL
DRAWINGS, MEP DRAWINGS, FIRE PROTECTIN DRAWINGS, ARCHITECTURAL
DRAWINGS, OR OTHERWISE NOTED OR REQUIRED.
MB-14 THE PEMB FRAMES SHALL BE DESIGNED TO SUPPORT A 10-TON SINGLE GIRDER,
TOP RUNNING BRIDGE CRANE EQUIPPED WITH A LOW-HEADROOM, BOTTOM
RUNNING TROLLEY.
MASONRY
M-1 MASONRY WORK MUST BE IN CONFORMANCE WITH THE MASONRY SOCIETY (TMS)
"BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONY
STRUCTURES - TMS 402 AND TMS 602 (LATEST EDITION) .
M-2 ALL MORTAR TO CONFORM TO ASTM C 270, TYPE M OR S .
A. PORTLAND CEMENT: ASTM C 150, TYPE I.
B. LIME: ASTM C 207
M-3 GROUT IS TO CONFORM TO ASTM C 476 AND HAVE A MINIMUM COMPRESSIVE
STRENGTH OF 2000 PSI.
A. SLUMP: 8 TO 10 INCHES.
B. MAXIMUM AGGREGATE SIZE: 3/8".
M-4 CONCRETE MASONRY TO HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
MASONRY (f'm) EQUAL TO 2,000 PSI AND:
A. HOLLOW BLOCK: ASTM C 90, LIGHT WT.
B. SOLID BLOCKS: ASTM C 90.
M-5 DEFORMED BAR REINFORCEMENT PER ASTM A 615/A 615M GRADE.
A. PROVIDE MINIMUM LAP SPLICES OF 48 BAR DIAMETERS.
B. PROVIDE BAR SPACERS AS REQUIRED TO PROPERLY LOCATE
REINFORCING WITHIN CMU CELLS.
M-6 HORIZONTAL REINFORCING SHALL BE AS INDICATED IN TYPICAL SECTIONS ON
SHEET S-301. NO ADDITIONAL LADDER TYPE JOINT REINFORCEMENT IS REQUIRED.
M-7 ALL MASONRY TO BE CONSTRUCTED USING A RUNNING BOND PATTERN. FULL BED
AND HEAD JOINTS MUST BE USED.
M-8 GROUT CELLS OF CMU SOLID FOR ALL MASONRY BELOW GRADE, CMU LINTELS,
BOND BEAMS, CELLS WITH VERTICAL REINFORCEMENT AND BELOW BEAM
BEARING PLATES.
M-9 ALL MASONRY WALLS TO BE TEMPORARILY BRACED UNTIL FLOOR OR ROOF
SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF STABILIZING THE
WALLS.
M-10 DOWEL REINFORCED MASONRY WALLS TO FOUNDATION. SIZE DOWELS TO MATCH
WALL REINFORCEMENT. LOCATE DOWELS IN CELLS TO CONTAIN WALL
REINFORCEMENT. LAP DOWELS WITH WALL REINFORCEMENT A MINIMUM OF 48 BAR
DIAMETERS UNO.
M-11 DURING CONSTRUCTION, COVER AND PROTECT THE TOPS OF MASONRY WALLS
AT THE END OF EACH DAY.
M-12 UNLESS NOTED OTHERWISE, PLACE TYPICAL CMU REINFORCEMENT IN CENTER OF
FULLY GROUTED CELLS AND SPACE AS FOLLOWS:.
A. FOR 8” CMU:(1) #5 VERTICAL AT 24” ON CENTER.
B. PROVIDE ADDITIONAL BARS AT CORNERS AND OPENINGS PER TYPICAL
DETAILS.
M-13 ALL CORNERS AND INTERSECTIONS TO BE TIED BY MASONRY BOND.
M-14 PROVIDE VERTICAL CMU VENEER CONTROL JOINTS AS INDICATED ON THE
ARCHITECTURAL DRAWINGS.
M-15 SPACE CMU VENEER ANCHORS PER PROJECT SPECIFICATIONS. PROVIDE
ADDITIONAL ANCHORS AT 8" OC AROUND OPENINGS.
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
A
B
C
D
E
F
21 2.1 3 4 51.1 4.9
29' - 3" 30' - 1" 34' - 2" 30' - 1"
131' - 10"
2' - 9" 2' - 9"
PORTAL FRAME
LOCATION
2' - 9"
PORTAL FRAME
LOCATION
PORTAL FRAME
LOCATION
LOW BAY
OHD, TYP 5 LOCATIONS.
PEMB MFR TO PROVIDE
FRAMING OF DOOR OPENINGS
REQD TO SUPPORT DOOR AND
RESIST LOADS IMPOSED
DURING OPERATION AND WIND
FORCES
HOOK LIMITS OF 10 TON OVERHEAD CRANE
OHD
OHD
OHD
OHD
C.9
S-505
S-505
S-505
S-505
S-505
S-505
S-505
S-505
S-505
S-505
S-505
RE: NOTE 1
4' - 0"
RE: NOTE 1
4' - 0"
R E
: N O
T E
RE NOTE 3
1. COORDINATE DIMENSIONS WITH OVERHEAD DOOR
SUPPLIER. ADJUST AS REQUIRED TO CLEAR OVERHEAD
DOOR AND ITS COMPONENTS.
2. CRANE RUNWAY BEAM TO BE PROVIDED BY PEMB MFR
AND SUPPORTED FROM PEMB FRAMES. SEE DETAIL
1/A301 FOR GERNERAL CONFIGURATION AND
REQUIRED HOOK HEIGHT INFORMATION.
3. SEE SHEET A-111 FOR DIMENSIONS.
NOTES - FRAMING PLAN
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4
A
P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -S
.r v t
/1
/2
:2
:5
A M
S-111
F R
A M
IN
G
P L A
N
J B
R O
C K
J D
'A N
IE
L L O
D B
A R
K E
R
L .H
Y N
A L
U S
-4 A
-S -1
3/32" = 1'-0"
FRAMING PLAN
SCALE: 3/32" = 1'-0"
0 8'-0" 16'-0" 32'-0"
A
M D
T
-0
-2
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
FLOOR OR
ROOF LINE
T/SLAB
RE: PLAN
T/FDN
RE: PLAN
OPENING
OPENING
(2) #5
LINTEL
RE: SCHEDULE
WALL "T" INTERSECTION
RE: 2B/S-506
WALL END OR JAMB
RE: 2C/S-506
WALL CORNER
RE: 2A/S-506
WALL BEYOND WALL BEYOND TYP WALL
REINFORCING
BOND BEAM REINFORCING
@ TOP COURSE
RE: GENERAL NOTES
NOTES:
1. GROUT LINTELS SOLID FOR 2'-0" (MIN) BEYOND OPENING.
2. CMU TO BE GROUTED SOLID FOR 16" EACH SIDE OF OPENINGS, UNO.
3. RE: TYP CMU WALL REINFORCING DETAILS FOR ADD'L INFO AT WALL ENDS,
CORNER & "T" INTERSECTION CONDITIONS.
4. ALL VERTICAL REINFORCEMENT TO BE DOWELED INTO FOOTING OR SLAB
BELOW. REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION.
5. VERTICAL REINFORCEMENT TO CONTINUE BEYOND FLOOR LINE WHEN NOT
AT ROOF LINE. BARS TO BE LAPPED AS REQUIRED PER GENERAL NOTES.
6. PROVIDE BOND BEAMS AT DETAIL 3/S-506 SPANDREL BEAM LOCATIONS,
DETAIL 4/S-506 LEDGER ANGLE LOCATIONS AND TOP OF PARPET.
RE: NOTE 6
RE: NOTE 5
(TYP)
NOTES:
1. AT CORNERS AND INTERSECTIONS, UNO, LAY 50% OF UNITS IN
MASONRY BOND WITH ALTERNATE UNITS BEARING NOT LESS
THAN 4" ON THE UNIT BELOW.
2. PROVIDE DOWELS FROM CONCRETE FOOTING OR WALL BELOW
W/ SAME SIZE AND SPACING AS VERTICAL BARS AT LEVEL ABOVE.
LAP 48 BAR DIAMETERS MIN UNO.
3. AT WALL JAMBS, INTERRUPT END BAR AT STEEL LINTEL.
WALL CORNER
A
WALL "T" INTERSECTION
B
WALL END OR JAMB
C
BOND BEAM REINF (TYP) (3) VERTICAL REINF TO
MATCH WALL REINF
RE: NOTE 3
48 BAR DIA MIN
LAP SPLICE
#3 REINF @
EA BOND BEAM
CMU WALL
(4) VERT REINF
TO MATCH
TYP WALL REINF
48 BAR DIA MIN
LAP SPLICE
BOND BEAM REINF (TYP)
TYP WALL
REINF
CMU WALL
48 BAR DIA MIN
LAP SPLICE
(3) VERT REINF TO
MATCH TYP WALL REINF
GROUT ALL CELLS
HAVING VERTICAL
REINF (TYP)
TYP WALL
REINF
CMU WALL
BOND BEAM REINF (TYP)
CL GIRT
COL
BOND BEAM COURSE
W/ (2) #5 CONT
VERT WALL REINF
CMU WALL
RE: ARCH
SPANDREL BEAM,
BY PEMB MFR
RE: NOTE 1
GROUT COURSE ABOVE
BOND BEAM SOLID
(2 CELLS EA. SIDE OF ANCHOR)
NOTE:
1. SPANDREL BEAMS SHALL BE PROVIDED AT ALL PEMB FRAME EAVES AND AT THE ELEVATION WHERE THE LOW BAY
PEMB FRAMES ARE CONNECTED INTO THOSE OF THE HIGH BAY. IN THE HIGH BAY, AN ADDITIONAL LINE OF SPANDREL BEAMS SHALL BE LOCATED AT 18'-0" ABOVE FINISHED FLOOR ON GRID LINES 'F', '2' AND '5'.
SIMILARLY ON GRID LINE 'C.9', PROVIDE A LINE OF SPANDREL BEAMS MID-WAY BETWEEN THE HIGH AND LOW BAY
ROOFS.
2. PROVIDE 3/8" X 8" WIDE PLATE @
A. 4'-0" OC ON GRID LINES 2, F, 5 (PLAN NORTH OF D)
B. 6'-0" OC ON GRID LINES 1, A, 5 (PLAN SOUTH OF D), AND D (PLAN WEST OF 2)
C. 2'-0" OC ON GRID LINE D (BETWEEN 2 AND 5)
3/4"øX2 1/2" LONG HEADED
STUD WELDED TO PLATE, TOP
AND BOTTOM
3/8" STIFFNER PLATE
3/4"ø THREADED ROD IN
2" LONG SLOTTED
HOLES AND WELDED
TO WT FLANGE (1/2" GAGE)
3/8"X8" PLATE,
RE: NOTE 2
WT5X22.5 TRIM STEM TO FIT
1/4
3 SIDES
5"
(2) 3/4" ⌀ x 5" LG
HEADED STUDS
1/4" 1/4"
CMU WALL
RE: PLAN
BEAM
RE: PLAN
BEARING PLATE
RE: SCHEDULE
FULL
LENGTH
OF PLATE
1/2" GROUT
GROUT BLOCK SOLID BELOW BEARING
(2 COURSES DEEP x TWICE DIM "L" MIN)
1/2" SETBACK
FILL POCKET SOLID
W/ MASONRY AFTER
SETTING BEAM
CL
BEAM
PLATE
L
BEAM
RE: PLAN
W
1/2" SETBACK
CMU WALL
RE: PLAN
CL
BEAM
PLATE
W
1/2" SETBACK
CMU WALL
RE: PLAN
1/2" GROUT
FILL POCKET SOLID
W/ MASONRY AFTER
SETTING BEAM
BEAM, RE: PLAN
GROUT BLOCK SOLID BELOW BEARING
(2 COURSES DEEP x TWICE DIM "L" MIN)
CMU WALL
RE: PLAN
(2) 3/4" ⌀ x 5" LG
HEADED STUDS
L
1/4" 1/4"
FULL
LENGTH
OF PLATE
1/2" SETBACK
BEAM PERPENDICULAR TO WALL
A
BEAM PARALLEL TO WALL
B
ENG NOTES:
CONSIDER NEED FOR SLOTTED
CONNECTION OF BEAM TO PLATE W/ FIELD
WELD AT AREAS THAT MAY BE SUBJECTED
TO DIFFERENTIAL LATERAL THERMAL
MOVEMENT DURING CONSTRUCTION.
IDENTIFY THOSE AREAS ON PLAN AND
PROVIDE SPECIFIC DETAIL.
BEARING PLATE, RE: SCHEDULE
AAAA
BBBB
SECTION AA
SECTION BB
BEAM BEARING SCHEDULE
MARK BEARING PLATE t x L x W TYPE
W8 1/2" x 10" x 0'-6 1/2" II
W16 1/2" x 10" x 0'-7" II
10" CMU WALL 4" CMU VENEER,
RE: ARCH
CONT L6x6x3/8 @
8'-0" O.C. VERTICAL
5/8"⌀x6" EMBED ADHESIVE
ANCHOR @ 48" O.C.
(Vu=0.9K, Tu=1.1K)
4"
10" CMU
BOND BEAM
THERMAL BREAK
MATERIAL, RE: ARCH
C.9
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4
A
P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -S
.r v t
/1
/2
:2
:0
A M
S-506
T Y
P
IC
A L M
A S
O N
R Y
D E
T A
IL
S
J B
R O
C K
J D
'A N
IE
L L O
D B
A R
K E
R
L .H
Y N
A L
U S
-4 A
-S -5
SCALE:NTS
CMU WALL REINFORCEMENT ELEVATION
SCALE:NTS
CMU WALL REINFORCEMENT DETAILS
SCALE:NTS
SPANDREL BEAM AT CMU WALL
NTS
BEAM BEARINGS ON CMU WALL
SCALE:NTS
TYPICAL 4" CMU LEDGER ANGLE
A
M D
T
-0
-2
A
M D
T
-0
-1
1 1
2 W
2Q R
R
_P la ns -0
R E
F
F E
C
F E F E
FE
FEFEFE
FE
F E
FEC
OFFICE
NEW
BATTERY
STORAGE
TR
CLASSROOM/
BREAK
LACTATION
G004
MENS RR
OFFICE
ELECTRICAL
G001
JAN
OPEN
OFFICE
COMSEC
SHOP 103
OFFICE
C001
CORRIDOR
G002
WOMENS
RR
CONTROLLED
WASTE
117B
WORKBAY
TOOLS/PARTS
MECHANICAL
FLUID
DISTRIBUTION
FLAMMABLE
STORAGE
OLD
BATTERY
STORAGE
BAY
SAFETY
AISLE
118A
EQUIPMENT
ALCOVE
A-301
A-301
G003
WOMENS
LOCKER
ROOM
G005
MENS
LOCKER
ROOM
A-201
A-201
A-202
A-202
A-301
A-301
A-301
A-301
110b
111112113114
115a
110a
119 C001a120
C001b
116a 116b
117c
117e
G002
G004
101a
G001
117a
117f117d
A-401
1A0.3b
1A0.3b
1A0.3b
1AS.3a
1A0.3b
1AS.3c
1B0.3
1A0.3c
1A0.3b
1A0.3b
1A0.3b
1A0.3b 1A0.3
6A1.8
6A0.8
6A2.8 6A2.8
6AS.10
1AS.3
1A0.3b
6AS.8
117D
WORKBAY
117E
WORKBAY
117F
WORKBAY
117A
WORKBAY
117C
WORKBAY
118B
EQUIPMENT
ALCOVE
A-701 6
1A0.3b
A
22.08
12.01
11.03
11.02
12.01
22.04
22.04
22.09
9.09
22.02
101b
1A0.3c
A-701
10.17
22.04
22.04
22.04
10.05
10.06
10.06 10.06
5.035.03
5.03
A-311
A-311
3' - 3" 6' - 4" 4' - 0" 6' - 4" 4' - 8" 6' - 4" 7' - 4" 6' - 4" 46' - 8" 3' - 4" 18' - 8" 3' - 4" 8' - 8" 3' - 4" 3' - 3"
1 2 3 4 5
F
E
D
C
B
A
2.1
1"
6'
6'
3'
3'
8'
6'
3'
8'
3'
3'
8'
3'
4'
3'
4'
3'
4'
3'
4'
3'
4'
3'
6'
4.9
6A2.8
6A2.8
6A1.8
6A2.8
6A2.8 6A2.8
6A2.10
LIMITS OF OVERHEAD CRANE
LIMITS OF
OVERHEAD CRANE
2' - 9" 29' - 3" 2' - 9" 30' - 1" 34' - 2" 30' - 1" 2' - 9"
0"
10.06
10.06
10.06
10.06
10.09
10.23
10.09 10.23
10.09
A-311
10.18
10.07
0.06
0.06 0.05
0.03
0.04
0.02
0.080.08
0.08
0.080.08
0.08
12' - 4" 8' - 0" 4' - 0" 4' - 0" 8' - 0" 12' - 4"
10.21 10.2110.2110.21
A-521
1.1
A-501
10.24
10.24
10.24
10.24
10.24
10.24
5.06
5.07 5.07
5.07 5.07
CRANE DIRECTION
99' - 10"
3'
131' - 10"
10.06
10.05
6A2.8
5'
6' - 0" 13' - 5" 11' - 2"
5'
8'
13' - 8" 21' - 3"
16' - 0"
3'
5' - 2"
5' - 2"
8' - 3"
11' - 1" 10' - 0" 12' - 8" 37' - 0"
8'
6A2.8
A-501
6A2.8
37' - 3" 25' - 0"
10.24
5.015.01
5.095.09
5.09
A-501
90' - 0" 3' - 7" TYP 1' - 9" TYP
115b
10.26
10.26
22.07
22.07
34' - 8"
TYP
8' - 2" 9' - 8 1/2"
110c
6A1.10
6A1.8
10.07
10.27
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4 A
P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
GRAPHIC SCALE / NORTH ARROW
J
A N
U A
R Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -A
.r v t
/1
/2
:5
:0
A
M
A-111
F L O
O R
P L A
N
J W
E A
V E
R
K C
L A
N C
Y
D B
A R
K E
R
J D
IL
L A
M A
N
U S
-4 A
-A -1
SCALE: 1/8" = 1'-0"
FLOOR PLAN
KEYNOTES
0.02 GFGI PORTABLE WELDER
0.03 GFCI GRINDER
0.04 GFGI PARTS WASHER
0.05 GFGI DRILL PRESS 1
0.06 GFGI DRILL PRESS 2
0.08 GFGI PORTABLE LIFT
5.01 8" DIA. CONCRETE FILLED W/ CONCRETE DOME TOP
PAINTED STEEL BOLLARD, S-SERIES
5.03 METAL GRATING, SEE S-SERIES. RECESSED SLAB THIS
AREA. EPOXY PAINT ON FLOOR AND WALLS UP TO
GRATING. SLOPE FLOOR TO EXTERIOR WALLS.
5.06 ROOF ACCESS SHIPS LADDER
5.07 HOSE REEL STANDS
5.09 PROVIDE REMOVABLE PORTION OF GRATING FOR
FLUID REMOVAL, SEE S-SERIES FRAMING LOCATIONS
9.09 SAFETY AISLE EPOXY FLOOR MARKING
10.05 SEMI-RECESSED FIRE EXTINGUISHER CABINET,
WEATHERPROOF AT EXTERIOR LOCATIONS
10.06 SURFACE MOUNTED FIRE EXTINGUISHER
10.07 WIRE MESH PARTITION W/ 9'-0" WIRE MESH CEILING
10.09 48"X48" TACK BOARD
10.17 WALL MOUNTED COAT HOOK BAR AND BLOCKING
10.18 TIERED FIBERGLASS SHELVING, SEE A-520
10.21 WORKBENCH
10.23 48"x48" MARKER BOARD
10.24 PLYWOOD PANELING UP TO 8'-0" AFF, GWB FROM 8'0"
TO ROOF DECK
10.26 PHENOLIC PLATE EGRESS PATH INDICATORS
ATTACHED TO METAL GRATE
10.27 RECESSED EMERGENCY KEY CABINETS, MOUNT 44"
AFF TO CENTER OF UNIT
11.02 REFRIGERATOR, SEE I-SERIES
11.03 MICROWAVE, SEE I-SERIES
12.01 SURFACE MOUNTED WALKOFF MAT- 10FT LONG IN
DIRECTION OF TRAVEL
22.02 ELECTRIC WATER COOLER, SEE P-SERIES
22.04 EMERGENCY SHOWER EYEWASH STATION, SEE
P-SERIES
22.07 FLOOR DRAIN, SLOPE FLOOR TO DRAIN,TYP., SEE
P-SERIES
22.08 WASH FOUNTAIN, SEE P-SERIES
22.09 SERVICE SINK, SEE P-SERIES
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/8" = 1' - 0"
NOTES - COMP FLOOR PLANS
1 REFER TO SHEET A-001 FOR ARCHITECTURAL GENERAL
NOTES, & ANNOTATION LEGEND
2 REFER TO A-600 SERIES FOR PARTITION TYPES
3 REFER TO ENLARGED PLANS AND INTERIOR ELEVATIONS
FOR ADDITIONAL INFORMATION
4 REFER TO MECHANICAL, ELECTRICAL, AND TELECOMM
SHEETS FOR EQUIPMENT LOCATIONS AND
REQUIREMENTS.
5 ALL DIMENSIONS SHOWN ARE TO FACE OF WALL (LEFT TO
RIGHT, BOTTOM TO TOP)- TYPICAL UNLESS NOTED
OTHERWISE
6 ALL DOORS TO BE INSTALLED 4" FROM HINGE SIDE OF
WALL - TYPICAL UNLESS NOTED OR DIMENSIONED
OTHERWISE
7 DIMENSIONS MARKED AS "CLEAR" DICTATES THE CLEAR
DIMENSION FROM FINISH TO FINISH
8 WHERE FIRE RATED PARTITIONS INTERSECT WITH
LESSER RATED PARTITIONS OR NON-RATED PARTITIONS,
THE HIGHER RATED PARTITION IS TO CONTINUE
THROUGH THE INTERSECTION TO MAINTAIN THE HIGHER
RATING
9 FIRE EXTINGUISHERS SHALL BE PROVIDED AND LOCATED
IN ACCORDANCE WITH NFPA 10. THE MAXIMUM TRAVEL
DISTANCE TO THE NEAREST FIRE EXTINGUISHER FROM
ANY POINT IN THE BUILDING SHALL NOT EXCEED 75 FEET.
REFERENCE EH101 HAZARDOUS LOCATION PLAN FOR
COORDINATION OF EQUIPMENT AND INSTALLATION
REQUIREMENTS
A
M D
T
-0
-0
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
FLOOR PLAN
0"
54.9
PREFINISHED COPING W/
TREATED WOOD BLOCKING
BELOW
ROOF CONSTRUCTION: RIGID EPDM
MEMBRANE
1/2" COVER BOARD
RIGID INSULATION - R-25 MIN.
ALUMINUM FRAMED WINDOW
PRECAST WINDOW SILL
WALL CONSTRUCTION:
8" SPLIT-FACE CMU
1" AIR SPACE
CONTINUOUS RIGID INSULATION - R-7.6
CONTINUOUS AIR/VAPOR BARRIER
EXTERIOR SHEATHING
METAL FRAMING W/ GWB FINISH
A-501
A-501
A-502
3'
FLOOR PLAN
0"
22.1
ROOF CONSTRUCTION: RIGID EPDM
MEMBRANE
1/2" COVER BOARD
RIGID INSULATION - R-25 MIN.
VERTICAL LIFT OVERHEAD DOOR
WALL CONSTRUCTION:
8" SPLIT-FACE CMU
2" AIR SPACE
CONTINUOUS RIGID INSULATION - R-7.6
CONTINUOUS AIR/VAPOR BARRIER
EXTERIOR SHEATHING
METAL FRAMING W/ GWB FINISH
PREFINISHED COPING W/
TREATED WOOD BLOCKING
BELOW
A-501
A-501
FLOOR PLAN
0"
F
PREFINISHED COPING W/
TREATED WOOD BLOCKING
BELOW
ROOF CONSTRUCTION: RIGID EPDM
MEMBRANE
1/2" COVER BOARD
RIGID INSULATION - R-25 MIN.
MECHANICAL LOUVER, SEE M-
SERIES
8" GROUND FACE CMU ACCENT
BAND
WALL CONSTRUCTION:
8" SPLIT-FACE CMU
2" AIR SPACE
CONTINUOUS RIGID INSULATION - R-7.6
CONTINUOUS AIR/VAPOR BARRIER
EXTERIOR SHEATHING
METAL FRAMING W/ GWB FINISH
FIRE TREATED 1/2" PLYWOOD TO
8'-0" ABOVE FINISH FLOOR
A-501
A-501
A-502
D
ROOF CONSTRUCTION: RIGID EPDM
MEMBRANE
1/2" COVER BOARD
RIGID INSULATION - R-25 MIN.
WALL CONSTRUCTION:
4" SPLIT-FACE CMU VENEER
2" AIR SPACE
CONTINUOUS RIGID INSULATION - R-7.6
CONTINUOUS AIR/VAPOR BARRIER
10" CMU WALL
PREFINISHED COPING W/
TREATED WOOD BLOCKING
BELOW
18' - 8"
A-501
A-501
15' - 4"
S M
O O
T H
F A
C E
V E
N E
E R
STRUCTURAL SUPPORT LINTEL, SPACED 8'-0" O.C.
VERTICALLY, SEE S-SERIES
STRUCTURAL SUPPORT LINTEL, SPACED 8'-0" O.C.
VERTICALLY, SEE S-SERIES
STRUCTURAL SUPPORT LINTEL, SPACED 8'-0" O.C.
VERTICALLY, SEE S-SERIES
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4 A
P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
GRAPHIC SCALE / NORTH ARROW
J
A N
U A
R Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -A
.r v t
/1
/2
:5
:0
A
M
A-311
W A
L L S
E C
T
IO
N S
J W
E A
V E
R
K C
L A
N C
Y
D B
A R
K E
R
J D
IL
L A
M A
N
U S
-4 A
-A -3
SCALE:
1' - 0" 2' - 0" 4' - 0"
1/2" = 1' - 0"
SCALE: 1/2" = 1'-0"
WALL SECTION
SCALE: 1/2" = 1'-0"
WALL SECTION
SCALE: 1/2" = 1'-0"
WALL SECTION
SCALE: 1/2" = 1'-0"
WALL SECTION
A
M D
T
-0
-0
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
FLOOR PLAN
0"
CAVITY DRAINAGE MATERIAL
WEEP INSERTS
THRU-WALL FLASHING
GROUT SOLID BELOW FLASHING
8" CONCRETE MASONRY
SPLIT FACE (CMU-B)
1" AIR SPACE
RIGID INSULATION (R-7.6 MIN)
CONTINUOUS BITUMINOUS
AIR/VAPOR BARRIER
CONTINUE AIR/ VAPOR
BARRIER TRANSITION
MEMBRANE OVER EDGE
OF FOUNDATION, 6" MIN
CONCRETE FOUNDATION,
SEE S-SERIES
A-502
PRECAST SILL
6" METAL FRAMING W/ GWB FINISH
EPDM ROOF MEMBRANE SYSTEM,
EXTEND UP PARAPET, UNDER
COPING, AND LAP OVER TREATED
BLOCKING
ALUMINUM COPING TRIM, SEE A12/A-510
CONTINUOUS BITUMINOUS
AIR/VAPOR BARRIER OVER EXT.
SHEATHING
8" CONCRETE MASONRY -
SPLIT FACE (CMU-A)
CONCRETE MASONRY VENEER -
GROUND FACE (CMU-B)
PROVIDE TRANSITION MEMBRANE
BETWEEN AIR/VAPOR BARRIER AND
ROOF MEMBRANE
SUPPORT FRAMING FOR
SHEATHING
CONTINUE AIR/VAPOR BARRIER
AROUND SPANDREL BEAM,
PROVIDE TRANSITION MEMBRANE
AS NEEDED
THROUGH-WALL HEAD FLASHING
WITH STAINLESS STEAL DRIP EDGE
CONTINUOUS BITUMINOUS AIR/VAPOR
BARRIER, WRAP INTO OPENINGS W/
TRANSITION MEMBRANE OVER EXT. SHEATHING
RIGID INSULATION (R-7.6)
8" CONCRETE MASONRY VENEER
CAVITY DRAINAGE MATERIAL
WALL OPENING STRUCTURE, SEE
S-SERIES
PRE-FINISHED METAL PANNING TO
CONCEAL OPENING AT HEAD AND JAMB
VERTICAL LIFT DOOR TRACK
WEEPS
COLD FORMED METAL FRAMING DESIGN
BY CONTRACTOR
GWB ON METAL FRAMING
CONTINUE TRANSITION MEMBRANE
AROUND STRUTURAL MEMBER
THROUGH-WALL FLASHING WITH
STAINLESS STEAL DRIP EDGE
WRAP AIR/VAPOR BARRIER ONTO SPANDREL
BEAM STEEL, USED TRANSITION MEMEBRANE
TO PROVIDE SEAL AT GAP AND BENDS
EPDM ROOF MEMBRANE SYSTEM,
EXTEND UP PARAPET, UNDER COPING,
AND LAP OVER TREATED BLOCKING
ALUMINUM COPING TRIM, SEE A12/A-510
CONTINUOUS BITUMINOUS AIR/VAPOR
BARRIER
RIGID INSULATION (R-7.6)
4" CONCRETE MASONRY
VENEER - GROUND FACE (CMU-B)
4" CONCRETE MASONRY VENEER -
SPLIT FACE (CMU-A)
38' - 0"
PROVIDE TRANSITION MEMBRANE BETWEEN
AIR/VAPOR BARRIER AND ROOF MEMBRANE
EPDM ROOF MEMBRANE SYSTEM,
EXTEND UP TO TRANSITION MEMBRANE
CONTINUOUS BITUMINOUS AIR/VAPOR
BARRIER
RIGID INSULATION (R-7.6)
CONCRETE MASONRY VENEER -
GROUND FACE (CMU-B)
PROVIDE TRANSITION MEMBRANE BETWEEN
AIR/VAPOR BARRIER AND ROOF MEMBRANE
CAVITY DRAINAGE MATERIAL AND WEEP
THERMAL BREAK MATERIAL
THROUGH WALL FLASHING W/
STAINLES STEEL DRIP EDGE
SEE S-SERIES FOR WALL REINFORCEMENT
STRUCTURAL SUPPORT ANGLE, SEE S-SERIES
15' - 4"
VAPOR RETARDER
OVER GRANULAR FILL -
SEE S-SERIES
CHEMICAL CONTAINMENT
PIT
GALVANIZED METAL
GRATING, SEE S-SERIES
GALVANIZED GRATING
SUPPORT - SEE S-
SERIES
EPOXY COATING AT
ENTIRE CONTAINMENT
PIT AREA
CONTINUE AIR/ VAPOR
BARRIER TRANSITION
MEMBRANE OVER EDGE
OF FOUNDATION, 6" MIN
CAVITY DRAINAGE MATERIAL
WEEP INSERTS
THRU-WALL FLASHING
GROUT SOLID BELOW FLASHING
8" CONCRETE MASONRY
SPLIT FACE (CMU-B)
1" AIR SPACE
1/2" PLYWOOD UP TO
8'-0" AFF.
VAPOR RETARDER
OVER GRANULAR FILL -
SEE S-SERIES
8" CONCRETE MASONRY
SPLIT FACE (CMU-B)
CHEMICAL CONTAINMENT
PIT
GALVANIZED METAL
GRATING, SEE S-SERIES
GALVANIZED GRATING
SUPPORT - SEE S-
SERIES
EPOXY PAINT ON FLOOR
AND WALL UP TO GRATING
2'
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4 A
P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
GRAPHIC SCALE / NORTH ARROW
J
A N
U A
R Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -A
.r v t
/1
/2
:5
:1
A
M
A-501
S E
C T
IO
N
D E
T A
IL
S
J W
E A
V E
R
K C
L A
N C
Y
D B
A R
K E
R
J D
IL
L A
M A
N
U S
-4 A
-A -5
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
SCALE:
6" 1' - 0" 2' - 0"
1 1/2" = 1' - 0"
SCALE: 1 1/2" = 1'-0"
SECTION DETAIL
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
OFFICE
CLASSROOM/
BREAK
TELECOM
LACTATION
OFFICE
ELECTRICAL
G001
JAN
OPEN
OFFICE
C001
CORRIDOR
COMSEC
SHOP
OFFICE
118A
EQUIPMENT
ALCOVE
117B
WORKBAY
G003
WOMENS
LOCKER
ROOM
G002
WOMENS
RR
G004
MENS RR
G005
MENS
LOCKER
ROOM
NEW
BATTERY
STORAGE
BAY
SAFETY
AISLE
MECHANICAL
FLUID
DISTRIBUTION
CONTROLLED
WASTE
FLAMMABLE
STORAGE
OLD
BATTERY
STORAGE
TOOLS/PARTS
(X2)
LF5
CH4
(X2)
R1 W1
R1 W1
CH3 T1
CH4(X4)
T3 R1 W1(X4)
(X4)
CH1
(X4)
D17 (X4)
CH4
(X2)
LF5
CH1
CH1
EQ3 EQ1
R1 W1
R5
D18
D18
D5 D5
R1
W1 CH4
(X2)
CH1
(X2)
LF2 LF2
EQ2
EQ4
IF501
1(X2)
(X2)
IF501
TL1
(X4)
MA2
(X4)
SP1
(X4)
MA2
(X2)
SP1
(X2)
EQ2
SP1
MA2
SP1
MA2
EQ5
SC4
A
2 2.1 3 4 4.9 5
B
C
D
E
F
1.1
EQ7
EQ7EQ7
EQ7
T2 (X3)
CH2
(X6)
EQ7
EQ7 EQ7
EQ7
CH1
R1
W1 MA2
SP1
D17
TL1
IF501
R4
R1
W1
LF5
SP1
WB1
TL2
CH5
EQ7
EQ7
117A
WORKBAY
117C
WORKBAY
117F
WORKBAY
117E
WORKBAY
117D
WORKBAY
118B
EQUIPMENT
ALCOVE
C.9
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
D
R M
A R
T
IN
L U
T H
E R
K
IN
G J
R P
L
L O
U
IS
V
IL
L E
K
Y
M
IC
H A
E L B
A K
E R
I N
T E
R N
A T
IO
N
A L
IN
C
A
IR
S
ID
E
D R
IV
E
M O
O N
T O
W N
S H
IP
P
A
C A
M P
P E
N D
L E
T O
N
O C
E A
N S
ID
E
C
A A
R E
A M
A
IN
T E
N A
N C
E S
U P
P O
R T
A C
T
IV
IT
Y
A
M S
A
U S
-4
A P
F
IL
E N
A M
E
P L O
T D
A T
E
IS
S
U E
D A
T E
J A
N U
A R
Y
A
GRAPHIC SCALE / NORTH ARROW
J A
N U
A R
Y
C E
R T
IF
IE
D F
IN
A
L
B
IM
/1 L
R L C a m p P e n d le to n A
M S
A /1
C a m p P e n d le to n A
M S
A -I
.r v t
/1
/2
:4
:1
A
M
IF111
IN
T
E R
IO
R
F U
R N
IT
U
R E
F
L O
O R
P L A
N
G D
O M
B R
O S
K A
S
J L U
T T
O N
D B
A R
K E
R
A M
Y E
R S
U S
-4 A
-I F
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/8" = 1' - 0"
SCALE: 1/8" = 1'-0"
FURNITURE - FLOOR PLAN
LEGEND - FURNITURE (GFGI)
TAG DESCRIPTION QTY
CH1 CHAIR - TASK WITH ARMS 9
CH2 CHAIR - PLASTIC STACKING WITH ARMS 6
CH3 CHAIR - LACTATION GLIDER 1
CH4 CHAIR - GUEST, STACKING WITH ARMS 10
CH5 CHAIR - TASK STOOL WITH ARMS 1
D5 DESK - L SHAPED - 48" RETURN, OH ON DESK 2
D17 DESK - L SHAPED - 42" RETURN, NO OH 5
D18 DESK - L SHAPED - 60" RETURN, OH ON RETURN 2
LF2 LATERAL FILE - 2H - METAL - 30"W X 18"D 2
LF5 LATERAL FILE - 5H - METAL - 36"W X 18"D 3
MA2 MONITOR ARM - SINGLE 9
R1 RECYCLING - 7 GALLON 11
R4 RECYCLING WASTE- 46 GALLON 2 STREAM 1
R5 RECYCLING - 50 GALLON ROLL OUT 1
SC4 STORAGE CABINET - METAL 36"W X 20"D 2
SP1 SURGE PROTECTOR 10
T1 TABLE - SIDE 24" X 24" 1
T2 TABLE - FLIP TOP - 24"W X 60"L 3
T3 TABLE - MEETING - 42" DIA. 1
TL1 TASK LIGHT - DESK 5
TL2 TASK LIGHT - MAGNIFYING 1
W1 WASTE - 7 GALLON 11
WB1 WORKBENCH WITH WOOD TOP - 60" W X 30"D 1
LEGEND - EQUIPMENT (CFCI)
TAG DESCRIPTION QTY
EQ2 EQUIPMENT - COUNTERTOP MICROWAVE 2
EQ4 EQUIPMENT - REFRIGERATOR - SINGLE DOOR W/
TOP FREEZER
EQ5 EQUIPMENT - REFRIGERATOR - UC 1
EQ7 FIRE EXTINGUISHER 10
LEGEND - EQUIPMENT (NIC)
TAG DESCRIPTION QTY
EQ1 EQUIPMENT - COPIER 1
EQ3 EQUIPMENT - SHREDDER 1
NOTES - INTERIOR FF&E
1 FURNITURE (GFGI) IS GOVERNMENT FURNISHED
GOVERNMENT INSTALLED AND IS NOT IN
CONSTRUCTION CONTRACT.
2 FURNITURE SHOWN FOR REFERENCE ONLY.
3 EQUIPMENT (CFCI) IS CONTRACTOR FURNISHED
CONTRACTOR INSTALLED. REFER TO DIVISION 10
SPECIFICATIONS.
4 EQUIPMENT (NIC) IS SHOWN FOR REFERENCE.
5 CONTRACTOR COORDINATES ELECTRICAL / DATA
REQUIREMENTS AND STRUCTURAL BLOCKING FOR
ITEMS PROVIDED BY USERS AS APPROVED BY THE
CONTRACTING OFFICER.
6 REFER TO A-111 FOR BUILT IN WORKBENCHES
A
M D
T
-0
-1
W
2Q R
R
_P la ns -0
| CS504 |
| S-002 |
| S-111 |
| S-506 |
| A-111 - FLOOR PLAN |
| A-311 - WALL SECTIONS |
| A-501 - SECTION DETAILS |
| IF111 - INTERIOR FURNITURE - FLOOR PLAN |
File details come from the government source that posted it. Updated .