W912QR24B0004_Plans-0000.pdf
PDF 31 MB Posted
- Solicitation number
- W912QR24B0004
About this file
This document appears to be a set of plans related to Solicitation Number W912QR24B0004 for the Construction Renovation of Building 10 at the Defense Supply Center (DSCC) in Columbus, OH. The solicitation is a 100% small business set-aside with a NAICS code of 236220 and an estimated size determination of $45M. The Department of the Army Corps of Engineers Engineering District Louisville is the procuring agency for this construction project. The plans likely provide detailed specifications and technical requirements for the renovation of Building 10 at the DSCC facility.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M
AR
K D
ES
C
R
IP
TI
O
N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:5
AM
G-001
C O
VE
R
S H
EE
T
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
.C
LA
R K
R .C
LA
R
K
J.
BL
EH
M
AR
C H
6, W
2Q R
-1 9-
D -0
LOUISVILLE DISTRICT
W912QR-19-D-0037
MARCH 16, 2024
COLUMBUS, OH
DSCC BUILDING 10 USMC OFFICE RENOVATION
P2: 509344
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
LOCATION MAP
VICINITY MAP
BLDG 10
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
ARIMS: 200A Disposition: Maintain for 15 yrs after construction.
29 March 2024
W912QR24B0004
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:0
AM
G-002
BLDG 10
SH
EE
T
IN
D E
X
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SHEET LIST
SHEET NUMBER SHEET NAME
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES AND DESIGN CRITERIA
S-002 STRUCTURAL ABBREVIATIONS
SD110 FLOOR SLAB DEMO PLAN
S-110 FLOOR SLAB PLAN
S-120 STORAGE CAGING FRAMING PLAN
S-211 TYPICAL FRAMING ELEVATION
S-351 FRAMING SECTIONS
S-401 ENLARGED STORAGE CAGING FRAMING PLANS
S-501 TYPICAL DETAILS
ARCHITECTURE
A-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
AS-100 ARCHITECTURAL SITE PLAN
AE110 EXISTING FLOOR PLAN
AD110 DEMOLITION FLOOR PLAN
AD111 DEMOLITION CEILING PLAN
AD401 DEMOLITION ENLARGED PLANS
AD402 DEMOLITION ENLARGED PLANS
A-110 FLOOR PLAN
A-111 CEILING PLAN
A-401 ENLARGED PLANS
A-402 ENLARGED PLANS
A-403 ENLARGED PLANS
A-404 ENLARGED PLANS
A-405 ENLARGED PLANS
A-406 ENLARGED CEILING PLANS
A-410 RESTROOMS / SHOWERS INTERIOR ELEVATIONS
A-411 RESTROOM INTERIOR ELEVATIONS
A-412 RESTROOM DETAILS
A-413 TYPICAL MOUNTING HEIGHTS
A-420 INTERIOR ELEVATIONS
A-540 WALL TYPES AND DETAILS
A-541 WALL SECTION
A-601 DOOR SCHEDULE AND DETAILS
A-602 DOOR DETAILS
INTERIORS
I-110 FINISH PLAN
I-601 FINISH SCHEDULE
I-602 FINISH KEY
INTERIORS GRAPHICS
IG110 SIGNAGE PLAN
IG501 SIGNAGE DETAILS
IG601 SIGNAGE SCHEDULE
INTERIORS FURNITURE
IF110 FURNITURE PLAN
IF501 FURNITURE DETAILS
IF502 FURNITURE DETAILS
LIFE SAFETY
LS001 ABBREVIATIONS, LEGEND, AND CODE ANALYSIS
LS002 FIRE PROTECTION / LIFE SAFETY / ACCESSIBILITY CODE REVIEW
LS110 LIFE SAFETY PLAN
FIRE SPRINKLER
FX110 FIRE PROTECTION PLAN
FIRE ALARM
FA110 FIRE ALARM PLAN
PLUMBING
P-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
PD100 UNDERGROUND DEMOLITION PLAN
PD111 SANITARY DEMOLITION PLAN
PD112 DOMESTIC WATER DEMOLITION PLAN
PD401 ENLARGED SANITARY DEMOLITION - SECTION 10
PD411 ENLARGED DOMESTIC WATER DEMOLITION - SECTION 10
PD412 ENLARGED DEMOLITION PLANS - SECTION 11
P-401 ENLARGED UNDERGROUND PLAN - SECTION 10
P-411 ENLARGED SANITARY PLAN - SECTION 10
SHEET LIST
SHEET NUMBER SHEET NAME
P-412 ENLARGED DOMESTIC WATER PLAN - SECTION 10
P-413 ENLARGED PLUMBING PLANS - SECTION 11
P-501 DETAILS
P-502 DETAILS
P-601 SCHEDULES
P-901 SANITARY DEMO RISER SECTION 10
P-902 SANITARY DEMO RISER SECTION 11
P-903 SANITARY RISER SECTION 10
P-904 SANITARY RISER SECTION 11
P-905 WATER RISER SECTION 10
P-906 WATER RISER SECTION 11
MECHANICAL
M-001 ABBREVIATIONS, LEGEND AND GENERAL NOTES
MD110 SECTION 10 AND 11 HVAC DEMOLITION PLAN
MD111 SECTION 10 HVAC DEMOLITION PLAN
MD112 SECTION 11 HVAC DEMOLITION PLAN
MD210 INSIDE DECK - SECTION 10 AND 11 HVAC DEMOLITION
MD211 INSIDE DECK - SECTION 10 HVAC DEMOLITION PLAN
MD212 INSIDE DECK - SECTION 11 HVAC DEMOLITION PLAN
MH110 SECTIONS 10 AND 11 - HVAC PLAN
MH111 SECTION 10 HVAC PLAN
MH112 SECTION 11 HVAC PLAN
MH210 UPPER LEVEL SECTION 10 AND 11 HVAC PLAN
MH211 UPPER LEVEL SECTION 10
MH212 UPPER LEVEL SECTION 11
MP110 SECTION 10 AND 11 PIPING PLAN
MP111 SECTION 10 PIPING PLAN
MP112 SECTION 11 PIPING PLAN
M-501 DETAILS
M-601 SCHEDULES
M-602 SCHEDULES-2
M-701 CONTROLS
M-702 CONTROLS
ELECTRICAL
E001 ELECTRICAL LEGEND
E002 ELECTRICAL GENERAL NOTES
E003 ELECTRICAL ABBREVIATIONS
E100 OVERALL EXISTING ELECTRICAL PLAN
ED111 SECTION 10 DEMOLITION LIGHTING PLAN
ED112 SECTION 11 DEMOLITION LIGHTING PLAN
ED113 SECTION 10 DEMOLITION POWER PLAN
ED114 SECTION 11 DEMOLITION POWER PLAN
ED601 POWER ONE-LINE DIAGRAM DEMO
ED602 POWER ONE-LINE DIAGRAM DEMO
ED701 EXISTING PANEL SCHEDULES
ED702 EXISTING PANEL SCHEDULES
ED703 EXISTING PANEL SCHEDULES
ED704 EXISTING PANEL SCHEDULES
ED705 EXISTING PANEL SCHEDULES
EL111 SECTION 10 LIGHTING PLAN
EL112 SECTION 11 LIGHTING PLAN
EL113 MAINTENANCE CORRIDOR LIGHTING PLAN
EL501 LIGHTING DETAILS
EL701 LIGHTING SCHEDULES
EP111 SECTION 10 POWER PLAN
EP112 SECTION 11 POWER PLAN
EP150 SECTION 10 & SECTION 11 HVAC POWER PLAN
EP501 POWER DETAILS
EP601 POWER ONE-LINE DIAGRAM
EP602 POWER ONE-LINE DIAGRAM
EP701 PANEL SCHEDULES
EP702 PANEL SCHEDULES
EP703 PANEL SCHEDULES
EP704 PANEL SCHEDULES
EY110 SECTION 10 & SECTION 11 SPECIAL SYSTEMS PLAN
EG501 GROUNDING DETAILS
TELECOMMUNICATIONS
T001 TELECOMMUNICATIONS LEGEND AND OUTLET SCHEDULE
T002 TELECOMMUNICATIONS GENERAL NOTES AND ABBREVIATIONS
TD110 LEVEL 1 - SECTION 10 AND 11 TELECOMMUNICATIONS DEMO
PLAN
T111 SECTION 10 TELECOMMUNICATIONS PLAN
T112 SECTION 11 TELECOMMUNICATIONS PLAN
T410 ENLARGED TELECOMMUNICATION PLANS
T501 COMMUNICATIONS DETAILS
T601 TELECOMMUNICATIONS ONE-LINE DIAGRAM
T602 TELECOMMUNICATIONS RACK ELEVATIONS
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
ARIMS: 200A Disposition: Maintain for 15 yrs after construction.
GENERAL
A. THESE GENERAL NOTES PRESENT AND/OR SUMMARIZE KEY PROJECT
INFORMATION FOR THE READER'S CONVENIENCE. SEE ALSO INDIVIDUAL
PLAN NOTES AND PROJECT SPECIFICATIONS FOR FURTHER DETAILS AND
REQUIREMENTS.
B. ALL REFERENCES TO REFERENCE STANDARDS HEREIN ARE TO MOST RECENT
IN EFFECT AS OF THE DATE OF THESE DOCUMENTS, UNLESS NOTED
OTHERWISE IN PROJECT SPECIFICATIONS OR ON THE PLANS.
C. ELEVATIONS. ALL ELEVATIONS ARE REFERENCED TO FINISHED FLOOR EL.
100'-0". ALL ELEVATIONS SHOWN ON PLANS ARE REFERENCED TO THE
SITE ELEVATION DATUM SHOWN ON FOUNDATION PLANS UNLESS NOTED
OTHERWISE.
D. SUBMIT SHOP DRAWINGS, PROJECT DATA AND SAMPLES AS SPECIFIED IN
PROJECT SPECIFICATIONS SECTION 01 33 00
1. IDENTIFY PROMINENTLY ON DRAWINGS EACH AND ALL RESUBMITTALS
BY NUMBER.
2. IDENTIFY ANY CHANGES WHICH HAVE BEEN MADE OTHER THAN THOSE
REQUESTED BY THE CONTRACTING OFFICER.
3. SUBMITTALS FAILING TO CONFORM TO THE ABOVE WILL BE RETURNED
FOR RESUBMITTAL.
E. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE BEGINNING WORK
OR FABRICATION AND THE CONTRACTING OFFICER SHALL BE NOTIFIED
IMMEDIATELY ON ANY DISCREPENCIES.
F. CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE SHORING AND
BRACING TO PROTECT UNFINISHED NEW CONSTRUCTION.
DESIGN CRITERIA
A. BUILDING CODES
2021 INTERNATIONAL BUILDING CODE.
UFC 3-301-01, STRUCTURAL ENGINEERING, 11 APR 2023.
ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES.
B. SUPERIMPOSED DESIGN LOADS
1. DEAD LOADS
SUSPENDED CEILING - 2 psf LIGHTS & FIRE SUPRESSION - 2 psf
2. LIVE LOADS
STORAGE CAGE ROOF - 20 psf HATCH OPENING INFILL - 20 psf
3. WIND
A. RISK CATEGORY II
B. ULTIMATE WIND SPEED - 107 MPH
C. NOMINAL WIND SPEED - 83 MPH
D. EXPOSURE CATEGORY - C
E. INTERNAL PRESSURE COEF., GCpi = +/-0.18
4. SEISMIC (STORAGE CAGE)
A. RISK CATEGORY II, IMPORTANCE FACTOR =1.0
B. MAPPED SPECTRAL RESPONSE ACCELERATIONS
SS = 0.115g S1 = 0.059g
C. SITE CLASSIFICATION - D (ASSUMED)
D. DESIGN SPECTRAL RESPONSE ACCELERATIONS
SDS = 0.123g SD1 = 0.094g
E. SEISMIC DESIGN CATEGORY - B
F. RESPONSE MODIFICATION FACTOR, R, AND SEISMIC RESPONSE COEFF,
CS: STEEL SYSTEMS NOT SPECIFICALLY DESIGNED FOR SEISMIC
RESISTANCE, R=3.0, Ω=3.0, Cd=3.0, Cs=0.04
G. DESIGN SEISMIC BASE SHEAR - 0.8 kips
H. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
I. FUTURE EXPANSION: NO PROVISION FOR FUTURE EXPANSION HAS
BEEN MADE THAT WILL IMPACT DESIGN PROVISIONS OF STRUCTURES
AND AND FOUNDATIONS UNDER THIS CONTRACT.
CAST-IN-PLACE REINFORCED CONCRETE CONTINUED
D. FORMWORK
1. SEE SPECS.
2. KEYS INDICATED ARE TO BE 2" x 4" NOMINAL CONTINUOUS, UNO.
3. RUSTICATION STRIPS, CHAMFERS, DRIPS, MISC. EMBEDS, ETC. SEE PLANS
AND/OR ARCHITECTURAL DRAWINGS.
4. OPENINGS FOR MP&E TRADES. ALL HOLES FOR OTHER TRADES WHICH
MUST BE CUT OR FORMED AND WHICH ARE NOT SHOWN ON THE
STRUCTURAL DESIGN(S) DRAWINGS SHALL BE SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW AND APPROVAL.
E. REINFORCEMENT
1. REINFORCING BARS. DEFORMED, GRADE 60, ASTM A615. ASTM A706
WHERE SPECIFIED AND FOR WELDING APPLICATIONS.
A. FABRICATION: ACI SP-66 (2004) "ACI DETAILING MANUAL"
2. WELDED SMOOTH WIRE FABRIC - ASTM A1064. FLAT SHEETS.
3. WELDING - ACI 301, SECTION 3.2.2.2.
4. CORNER BARS. PROVIDE CORNER BARS SAME SIZE AND SPACING AS
HORIZONTAL REINFORCEMENT AT INTERSECTIONS OF ALL WALLS AND
WALL FOUNDATIONS.
5. SPLICES. CONTINUOUS REINF. BARS INCLUDING CORNER BARS SHALL BE
LAPPED THE LENGTH SHOWN IN THE DEVELOPMENT / LAP SPLICE TABLE
SHOWN ON THE DESIGN DRAWINGS, AND IN ACCORDANCE WITH ACI 318.
6. MINIMUM COVER FOR PROTECTION TYPICAL, UNO.
A. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH - 3"
B. FORMED SURFACE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18 BARS - 2"
#5 AND SMALLER - 1 3/4"
C. STRUCTURAL SLABS AND WALLS NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND - 3/4"
D. BEAMS AND COLUMNS: PRIMARY REINFORCEMENT, TIES, STIRRUPS,
AND SPIRALS NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND - 1 1/2"
7. HOOKS INDICATED ARE ACI/CRSI STANDARD 90 DEG. OR 180 DEG. HOOKS.
BAR LENGTHS SHOWN ARE OUT-TO-OUT AND DO NOT INCLUDE HOOK
LENGTH.
F. ELECTRICAL TRADES. FIELD REQUIREMENTS NOT SHOWN ON STRUCTURAL
PLANS MUST BE APPROVED BY THE CONTRACTING OFFICER. ANY
STRENGTHENING OR ADDITIONAL REINFORCEMENT REQUIRED SHALL BE
FURNISHED BY THE CONTRACTOR WITHOUT ADDITIONAL COST TO THE
GOVERNMENT. PLUMBING SLOTS ARE TO BE FILLED WITH CONCRETE TO
SAME THICKNESS AS SLAB OR WALL AFTER PIPING HAS BEEN INSTALLED. SEE
TYPICAL SLAB PENETRATION DETAILS FOR REQUIREMENTS.
G. EMBEDDED PIPES OR CONDUIT. MAXIMUM DIAMETER - 1/3 x SLAB OR WALL
THICKNESS, SPACED MINIMUM OF 3 DIAMETERS ON CENTER.
H. GROUT. HIGH STRENGTH, NON-SHRINK STRUCTURAL GROUT. SEE SPECS.
I. CONCRETE FINISHES. SEE SPECS.
1. FORMED SURFACES:
A. PAINTED OR EXPOSED TO VIEW: RUBBED, UNO. ON PLANS
B. COVERED OR AS NOTED ON PLANS: AS-CAST
2. FLATWORK SURFACES:
A. EXPOSED TO VIEW: TROWELED WITH SURFACE TREATMENT
B. TILED OR CARPETED: TROWELED
C. STAIRS OR RAMPS: BROOMED
D. SIDEWALKS, DRIVEWAYS: BROOMED OR BELTED
J. CURING AND PROTECTION. SEE SPECS.
CAST-IN-PLACE REINFORCED CONCRETE
A. DESIGN CODE. ACI 318-19 - STRENGTH DESIGN. REFERENCE STANDARD: ACI
301. CONTRACTOR TO MAINTAIN COPY AT JOB SITE.
B. MIX DESIGN SHALL BE DOCUMENTED IN ACCORDANCE WITH SECTION
03 30 00 OF THE PROJECT SPECS AND ACI 301, CHAPTER 3 "PROPORTIONING".
MIX DESIGNS WHICH ARE SUBMITTED WITHOUT THE REQUIRED
DOCUMENTATION WILL BE REJECTED. FIELD SLUMPS RECORDED AT JOB SITE
SHALL NOT EXCEED THE SLUMP ESTABLISHED FOR THE MIX DESIGN.
C. CONCRETE. REFER TO SPECS.
1. ALL CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 4000 psi AT 28
DAYS.
2. ALL CONCRETE, EXCEPT INTERIOR FLOOR SLABS, SHALL BE AIR-
ENTRAINED, SEE SPECS.
COLD-FORMED STEEL FRAMING
A. DESIGN COLD-FORMED STEEL TO CONFORM TO THE INTERNATIONAL
BUILDING CODE 2021, THE LATEST EDITIONS OF THE "SPECIFICATION FOR THE
DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS" BY THE AMERICAN
IRON AND STEEL INSTITUTE (AISI), AND ANY OTHER CODES, OR REGULATIONS
HAVING JURISDICTION.
B. THE COLD FORMED STEEL SHOWN IS THE APPROXIMATE RELATIONSHIP
BETWEEN THE FRAMING AND ADJACENT SUPPORTING OR SUPPORTED
COMPONENTS. DETERMINE THE FINAL APPROPRIATE CONFIGURATION TO
SUPPORT THE REQUIRED LOADS.
C. FRAMING MEMBERS MUST BE CHANNEL-TYPE SECTIONS ROLL-FORMED FROM
CORROSION-RESISTANT STEEL MEETING ASTM A653, AND MEETING THE
CRITERIA IN SPEC 05 40 00.
D. DESIGN WELDING TO BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL
WELDING CODE - SHEET STEEL", AND AS FOLLOWS:
1. SHIELDED METAL ARC (STICK) WELDING FOR 18 GA. AND HEAVIER.
2. GAS METAL ARC (MIG) WELDING FOR 20 GA.
E. THE FINAL DESIGN OF THE COLD-FORMED METAL FRAMING SYSTEM MUST BE
THE RESPONSIBILITY OF THE QUALIFIED PROFESSIONAL SPECIALTY
ENGINEER HIRED BY THE CONTRACTOR. SUBMIT SHOP DRAWINGS AND
CALCULATIONS FOR REVIEW BY ENGINEER OF RECORD AND APPROVED BY
THE CONTRACTING OFFICER PRIOR TO FABRICATION AND PROCUREMENT OF
MATERIALS. SHOP DRAWINGS MUST BE SIGNED AND SEALED BY A
PROFESSIONAL ENGINEER. THE SHOP DRAWINGS MUST INCLUDE FRAMING
PLANS WITH DIMENSIONAL LOCATIONS, AS WELL AS REQUIRED DETAILS. THE
CALCULATIONS MUST INCLUDE INPUT LOADS, DEAD AND LIVE LOAD
DEFLECTIONS, REACTIONS, MEMBER FORCES, MEMBER SIZES, AND REQUIRED
MEMBER BRACING.
GENERAL STRUCTURAL NOTES
METAL ROOF DECK
A. FABRICATOR SHALL PROVIDE ANGLES, CHANNELS, ETC. AS REQUIRED TO
SUPPORT METAL DECK WHERE STRUCTURAL MEMBERS ARE NOT PRESENT.
B. MATERIAL SHALL BE ASTM A653 TYPE SS (50 ksi MIN. YIELD STRENGTH)
C. METAL ROOF DECK SHALL BE 1 1/2" DEEP, 0.0295" THICK (22 GAGE) TYPE B
WIDE RIB.
D. INSTALLATION.
1. WHERE POSSIBLE, EXTEND OVER 3 OR MORE SUPPORTS.
DECK ATTACHMENTS SHALL BE IN ACCORDANCE WITH SDI SPECS AND
SHALL BE ADEQUATELY SHOWN ON DECK SHOP DRAWINGS FOR FIELD
INSTALLATION.
2. DECK ATTACHMENT SHALL BE WITH 3/4" PUDDLE WELDS ON 36/4
PATTERN WITH #10 SCREW SIDELAP FASTENERS AT 20" OC MAX OR WITH
MECHANICAL FASTENERS ON A PATTERN PRODUCING STRENGTH AND
STIFFNESS AT LEAST EQUAL TO THE WELDED ATTACHMENT. WELDED
SIDELAPS NOT PERMITTED.
3. OTHER MECHANICAL FASTENERS OR WELDS ON A PATTERN PRODUCING
STRENGTH AND STIFFNESS AT LEAST EQUAL TO THE ATTACHMENT
SHOWN MAY BE SUBMITTED FOR APPROVAL. WELDED SIDELAPS NOT
PERMITTED.
E. ALL ACCESSORIES SUCH AS, BUT NOT LIMITED TO: RIDGE, HIP, AND VALLEY
PLATES ATTACHED DIRECTLY TO STEEL DECK INCLUDED. SHALL MATCH
THICKNESS AND GAGE OF ROOF DECK.
F. PROVIDE G90 GALVANIZED FINISH.
G. SUBMIT SHOP DRAWINGS PRIOR TO PROCUREMENT OF MATERIALS. SEE
SPECIFICATIONS FOR REQUIREMENTS.
POST-INSTALLED ANCHORAGES
A. THE CONTRACTOR SHALL INSTALL AND SECURE ALL REINFORCING STEEL
INDICATED IN THESE CONSTRUCTION DOCUMENTS PRIOR TO CONCRETE
PLACEMENT. THE USE OF POST-INSTALLED REINFORCING STEEL SYSTEMS
WILL BE CONSIDERED FOR REMEDIAL PURPOSES, SUBJECT TO THE
APPROVAL OF THE CONTRACTING OFFICER.
B. ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED AND SURFACES
PREPARED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS, THE PROJECT SPECIFICATIONS, AND ANY APPLICABLE
CODES.
C. ALL ANCHORAGES TO HOLLOW CMU SHALL BE MADE USING A TWO
COMPONENT ADHESIVE SYSTEM WITH SCREEN TUBE IN A PREDRILLED HOLE
PER THE MANUFACTURER'S INSTRUCTIONS, UNLESS NOTED OTHERWISE THE
MINIMUM EMBEDMENT AND ALLOWABLE SHEAR AND TENSION CAPACITIES
SHALL BE BASED ON THE HILTI HIT-HY 270 SYSTEM OR OTHER APPROVED
SYSTEM WITH EQUIVALENT OR GREATER CAPACITIES INCLUDING REQUIRED
REDUCTIONS DUE TO SPACING AND EDGE DISTANCES.
STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL WORK SHALL BE IN ACCORDANCE WITH THE AISC
"STEEL CONSTRUCTION MANUAL”, FIFTEENTH EDITION, WITH SUPPLEMENTS.
B. MATERIAL SPECIFICATIONS:
WIDE FLANGE SHAPES ASTM A992
ANGLES ASTM A36, GRADE 36
CHANNELS ASTM A36, GRADE 36
STRUCTURAL TUBING (HSS) ASTM A500, GRADE C
PIPE ASTM A53, GRADE B
PLATES AND BARS ASTM A36, GRADE 36
HIGH STRENGTH BOLTS ASTM F3125, GRADE A325
ASTM F3125, GRADE A490 (for D>1")
ASTM F3125, GRADE F1852, F2280
ANCHOR BOLTS ASTM F1554, GRADE 36, 55
HARDENED STEEL WASHERS ASTM F436, F959
HEADED STUD SHEAR CONNECTORS ASTM A108, GRADE 1015 OR 1020
C. CONNECTIONS SHALL MEET AISC MANUAL STANDARD CONNECTIONS UNLESS
NOTED.
1. HIGH-STRENGTH BOLTS: BEARING TYPE INSTALLED IN CONFORMANCE
WITH "SPECIFICATIONS FOR STRUCTURAL JOINTS USING HIGH-STRENGTH
BOLTS", RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS. UNLESS
NOTED OTHERWISE, STANDARD AISC "USUAL GAGE" DIMENSIONS SHALL BE
USED FOR LOCATING HOLES FOR BOLTS, EXPANSION ANCHORS, ETC. IN
ALL ANGLES, BEAM FLANGES, ETC.
2. WELDS: AWS D1.1, SERIES E70XX. ALL WELDS SHALL BE SUBJECT TO
INSPECTION AND NONDESTRUCTIVE EXAMINATION AS REQUIRED IN
SPECIFICATIONS. WHERE WELD SIZE IS NOT INDICATED ON THE
DRAWINGS, USE MINIMUM SIZE FOR PREQUALIFIED JOINTS PER AWS D1.1.
D. TOLERANCES SHALL MEET AISC CODE OF STANDARD PRACTICE 2016,
SECTION 6.4, 7.12, AND 7.13. ENSURE ALL STRUCTURAL STEEL MEETS THE
TOLERANCES SPECIFIED IN AISC 303-10.
E. PROVIDE POSITIVE CAMBER AS NOTED ON PLANS. WHERE NO CAMBER IS
NOTED, RESIDUAL MILL CAMBER IS TO BE UPWARDS.
F. ROOF OPENINGS: VERIFY SIZE AND LOCATION OF REQUIRED OPENINGS WITH
MECHANICAL, PLUMBING, OR OTHER TRADES AS NECESSARY TO ASSURE
CORRECT FRAMING AND SUBMIT ON SHOP DRAWINGS. PROVIDE SUB-
SUPPORT AS REQUIRED FOR DECK CLOSURES, INCLUDING AT COLUMNS.
COORDINATE WITH DECK SUPPLIER.
G. SHOP DRAWINGS: SUBMIT ERECTION AND FABRICATION SHOP DRAWINGS,
STAMPED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER. SEE
SPECIFICATIONS.
H. ALL WELDS TO BE SHOP WELDED UNLESS NOTED OTHERWISE.
I. ALL COLUMN BASE AND BEAM BEARING PLATES SHALL BE GROUTED WITH
NON-SHRINK NON-METALLIC GROUT AS INDICATED. GROUTING SHALL BE
COMPLETED AFTER THE STEEL FRAMING HAS BEEN PERMANENTLY PLUMBED.
J. FABRICATOR SHALL PROVIDE ANGLES, CHANNELS, ETC. AS REQUIRED TO
SUPPORT METAL DECK WHERE STRUCTURAL MEMBERS ARE NOT PRESENT.
K. THE MINIMUM PLATE THICKNESS SHALL BE 3/8 INCH UNLESS NOTED
OTHERWISE.
L. THE MINIMUM BOLT DIAMETER SHALL BE 3/4 INCH UNLESS NOTED
OTHERWISE.
M. THE MINIMUM WELD THROAT SIZE SHALL BE 1/4 INCH UNLESS NOTED
OTHERWISE.
N. CONNECTIONS SHALL HAVE A MINIMUM OF 2 BOLTS UNLESS OTHERWISE
NOTED.
O. NO TORCH CUTTING OR DRILLING IS PERMITTED IN FIELD WITHOUT WRITTEN
APPROVAL FROM THE CONTRACTING OFFICER.
P. ALL STEEL FRAMING SHALL BE CONSTRUCTED TRUE AND PLUMB AND SHALL
BE ASSUMED UNSTABLE UNTIL ALL COMPONENTS (WALLS, ROOFS, ETC.),
CONNECTIONS, AND PERMANENT BRACING ARE COMPLETELY INSTALLED.
Q. THE CONTRACTOR SHALL DESIGN AND PROVIDE TEMPORARY BOLTING AND
BRACING AS REQUIRED TO SAFELY CARRY ALL LOADS THE STRUCTURE MAY
BE SUBJECTED TO THROUGHOUT THE CONSTRUCTION PROCESS, INCLUDING
EQUIPMENT AND OPERATION.
R. ALL STRUCTURAL STEEL EXPOSED TO WEATHER, INCLUDING STEEL LINTELS,
SHALL BE GALVANIZED.
S. FOR ALL STRUCTURAL STEEL EXPOSED TO WEATHER WHERE GALVANIZATION
IS NOT POSSIBLE, INCLUDING STEEL LINTELS, PROVIDE HIGH PERFORMANCE
EPOXY PAINT PER SPECIFICATIONS. PREPARE STEEL AND APPLY PER
MANUFACTURERS INSTRUCTIONS.
T. PROVIDE COMPLETE COAT OF SHOP PAINT, AND TOUCH UP IN FIELD AFTER
INSTALLATION AS REQUIRED FOR ALL EXPOSED STEEL.
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:2
AM
S-001
BLDG 10
G
EN
ER
AL
S
TR
U C
TU
R
AL
N
O
TE
S
AN
D D
ES
IG
N C
R
IT
ER
IA
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
.G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D .D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
BAR SIZE
DEVELOPMENT / LAP SPLICE LENGTH IN CONCRETE
DEVELOPMENT LENGTH, in.
6 29
LAP SPLICE LENGTH, in.
10 60
7 42 54
11 67 87
NOTE: FOR HORIZONTAL REINFORCEMENT PLACED SUCH THAT MORE THAN
12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW REINFORCEMENT,
MULTIPLY THE VALUES BY 1.3.
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:5
AM
S-002
BLDG 10
ST
R
U C
TU
R
AL
A
BB
R
EV
IA
TI
O
N S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
@ AT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ADH ADHESIVE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ARCH ARCHITECT, ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BRG BEARING
CFS COLD FORMED STEEL
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
D DEPTH
DEMO DEMOLITION
DIA, Ø DIAMETER
DIAG DIAGONAL
DL DEAD LOAD
DTL DETAIL
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMBED EMBEDMENT
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EXP EXPANSION
FD FLOOR DRAIN
FDN FOUNDATION
STRUCTURAL ABBREVIATIONS
FF FINISH FLOOR
FLR FLOOR
HORIZ HORIZONTAL
IBC INTERNATIONAL BUILDING CODE
JT JOINT
LL LIVE LOAD
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
NIC NOT IN CONTRACT
NO, # NUMBER
NTS NOT TO SCALE
OC ON CENTER
PE PROFESSIONAL ENGINEER
PL PLATE
REINF REINFORCING
REQD REQUIRED
SCHED SCHEDULE
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STIF STIFFENER
STL STEEL
STRUC STRUCTURE(AL)
T&B TOP AND BOTTOM
TO TOP OF
TOS TOP OF STEEL
TOSL TOP OF SLAB
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VB VAPOR BARRIER
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDTH
w/ WITH w/o WITHOUT
WP WORKING POINT
WT WEIGHT
WWR WELDED WIRE REINFORCEMENT
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
TYP1
JIHGF
EDCBA
KEYPLAN
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:3
AM
SD110
BLDG 10
FL
O
O R
S
LA
B D
EM
O
P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
FLOOR SLAB DEMO PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS PRIOR TO DEMOLITION.
3 DEMOLISH AND REPLACE EXISTING 6.5" THICK SLAB ON
GRADE ABOVE ALL UNDERSLAB UTILITY WORK. REFER TO
TYPICAL SLAB REPLACEMENT DETAIL ON S-501.
SHEET KEYNOTES
1 SAWCUT PERIMETER AND DEMO EXISTING CONCRETE
SLAB ON GRADE. CONTRACTOR SHALL REFER TO UTILITY
PLANS FOR EXACT DEMO LOCATIONS.
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
TYP1
EDCBA
TYP3
TY
P
8'
0" 5"
T
YP
5" T
YP
S-211
TYP 4
5" T
YP
5" TYP
KEYPLAN
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:4
AM
S-110
BLDG 10
FL
O
O R
S
LA
B
PL
AN
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
FLOOR SLAB PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
2 EXISTING 6.5" THICK CONCRETE SLAB ON GRADE.
SHEET KEYNOTES
1 NEW SLAB INFILL TO MATCH THICKNESS OF EXISTING
SLAB ON GRADE. SEE DETAIL ON SHEET S-501.
2 NEW SHOWER LOCATIONS. REFER TO TYPICAL SHOWER
STALL FLOOR DRAIN DETAIL ON SHEET S-501.
3 FLOOR DRAIN. REFER TO FLOOR DRAIN DETAIL ON SHEET
S-501.
4 HSS 4x4x3/16 COLUMN.
5 EQUIPMENT PAD FOR OUTDOOR PACKAGED GENERATOR
- OPTION. REFER TO DETAIL 6/S-501.
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
EDCBA
40' - 4"
/2
32' - 0" 8' - 0"
40' - 0"
S-401
KEYPLAN
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:3
AM
S-120
BLDG 10
ST
O
R
AG
E C
AG
IN
G F
R
AM
IN
G
P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
STORAGE CAGING FRAMING PLAN
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
LEVEL 1
100' - 0"
TY
P
1'
4"
TYP
1' - 4"
TOS EL = 112' - 8"
EXISTING CONC SLAB
S-501
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:5
AM
S-211
BLDG 10
TY
PI
C
AL
F R
AM
IN
G E
LE
VA
TI
O
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/2" = 1'-0"S-110
TYPICAL FRAMING ELEVATION1
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
CFS JST,
SEE PLAN
MTL ROOF DECK,
SEE PLAN
STL BM,
SEE PLAN
1/2" DIA A325
THRU BOLT
L3x3x1/4 x0'-3 1/2"
LONG
3/16
CONNECTION
DESIGNED BY
CFS MFR
CONNECTION
DESIGNED PER
05 12 00
CFS JST,
SEE PLAN
MTL ROOF DECK,
SEE PLAN
CFS TRACK
TO MATCH JST
STL BM,
SEE PLAN
STL COL,
SEE PLAN
L3x3x1/4 x0'-3 1/2" LONG
3/16
CONNECTION
DESIGNED BY
CFS MFR
CFS JST,
SEE PLAN
STL BM,
SEE PLAN
STL COL,
SEE PLAN
MTL ROOF DECK,
SEE PLAN
L3X3x1/4 x0'-3 1/2"
LONG
3/16
CONNECTION
DESIGNED BY
CFS MFR
MTL ROOF DECK,
SEE PLAN
CFS JOIST,
SEE PLAN
CFS CLIP ANGLE.
DESIGN AND
CONNECTION BY
CFS MFR
STL BM,
SEE PLAN
OVERLAP
1' - 0"
DIMENSION OF OPENING
REFER TO ARCH FOR
FASTEN TO EXISTING
DECK w/ #10 SCREW
FASTENERS ON 36/4
PATTERN EA SIDE OF
OPENING
NEW 1 1/2" DEEP 22 GA STL ROOF DECK
INFILL TO MATCH SPAN DIRECTION OF
EXISTING
EXISTING HATCH STRUCTURAL FRAMING
(ACTUAL MEMBER SIZE AND SHAPE NOT
KNOWN)
STL COL,
SEE PLAN
HSS4x4x3/16 BRACE, TYP
3/8" GUSSET PL, TYP
STL BM,
SEE PLAN
4"
1"
3/16 3 3/16 3
TYP
3/16 3/16
3/16 3/16
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:3
AM
S-351
BLDG 10
FR
A
M
IN
G S
E C
TI
O
N S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1 1/2" = 1'-0"S-401
SECTIONA
SCALE: 1 1/2" = 1'-0"S-401
SECTIONB
SCALE: 1 1/2" = 1'-0"S-401
SECTIONC
SCALE: 1 1/2" = 1'-0"S-351
SECTIOND
SCALE: 1 1/2" = 1'-0"S-351
TYPICAL HATCH OPENING DETAIL1
SCALE: 1 1/2" = 1'-0"S-351
TYPICAL KNEE BRACE CONNECTION2
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
A S-351
B S-351
C S-351
D S-351
S-211
800S250-97
@24" OC
800S250-97
@24" OC
800S250-97
@24" OC
TYP 1
TYP 2
TYP 1
TYP2
8'
0" T
YP
H
SS
5X 4X
1/
H
SS
5X 4X
1/
H
SS
8X 4X
3/
HSS8X4X3/16 HSS8X4X3/16 HSS8X4X3/16
H
SS
5X 4X
1/
H
SS
5X 4X
1/
HSS5X4X1/8 HSS5X4X1/8 HSS5X4X1/8 HSS5X4X1/8 HSS5X4X1/8
H
SS
5X 4X
1/
H
SS
5X 4X
1/
H
SS
8X 4X
3/
H
SS
5X 4X
1/
H
SS
5X 4X
1/
HSS5X4X1/8HSS5X4X1/8HSS5X4X1/8HSS5X4X1/8HSS5X4X1/8
HSS5X4X1/8
H
SS
5X 4X
1/
H
SS
8X 4X
3/
H
SS
5X 4X
1/
HSS5X4X1/8 HSS5X4X1/8 HSS5X4X1/8 HSS5X4X1/8
H
SS
5X 4X
1/
HSS5X4X1/8
H
SS
5X 4X
1/
H
SS
5X 4X
1/
HSS5X4X1/8HSS5X4X1/8HSS5X4X1/8HSS5X4X1/8
8' - 0" TYP
40' - 0"
8'
0" T
YP
32' - 0" 8' - 0"
8' - 0" TYP
8'
0" 6'
0"
GRAPHIC SCALE:
4' 0 8' 12'4' 16'2'
3/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:5
AM
S-401
BLDG 10
EN
LA
R G
ED
S
TO
R
AG
E
C
AG
IN
G
F R
AM
IN
G P
LA
N
S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
LEGEND
INDICATES SPAN DIRECTION OF 1 1/2" METAL
ROOF DECK. SEE GENERAL NOTES FOR
ATTACHMENT REQUIREMENTS.
SCALE: 3/16" = 1'-0"S-120
ENLARGED STORAGE CAGING FRAMING PLANS1
GENERAL SHEET NOTES
1 REFER TO S-001 AND S-002 FOR GENERAL NOTES.
SHEET KEYNOTES
1 HSS 4x4x3/16 COLUMN.
2 HSS 4x4x3/16 KNEE BRACE.
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
SPLICE SCHED
SEE LAP 6" MIN.
REINFORCE w/
#3@12" EW
VAPOR BARRIER
CAPILLARY
WATER BARRIER
M
AT
C H
E
XI
ST
D
REINFORCE w/ #3
DOWELS @ 12", UNO
DRILL AND EPOXY #3 @ 2'-0" OC
MID-DEPTH INTO EXISTING SLAB
AS SHOWN
D /2
NEW SLAB EXISTING SLAB
D /3
OPENING GREATER THAN 3'-0" OPENING 3'-0" OR LESS
VAPOR BARRIER
CAPILLARY
WATER BARRIER
M
AT
C H
E
XI
ST
D
DRILL AND EPOXY INTO
EXISTING SLAB AS SHOWN
D /2
NEW SLAB EXISTING SLABEXISTING SLAB
#3@12", (2) BARS MIN.
6"
SCHEDULE
SEE LAP
SPLICE
D /2
BARS IN
SAME PLANE
NOTE: PROVIDE TOOLED CONTROL JOINT SPACING OF 125% TIMES THE
WIDTH OF THE SLAB OR 15' (MAX), AND AT RE-ENTRANT CORNERS.
(MIN WIDTH 2'-1")
FF EL
SEE PLAN
FD
VAPOR BARRIER
CAPILLARY
WATER BARRIER
CONC SLAB,
SEE PLAN
NOTES:
1. SET UP DRAIN AS REQUIRED TO RECEIVE FLOOR
FINISH. SEE ARCH DRAWINGS.
2. SEE ARCH AND MECH DRAWINGS FOR SIZE AND
LOCATION OF FLOOR DRAINS.
1/
2" UNO
2' - 0" RADIUS
FD
SLOPESLOPE
CL
FF EL
SEE PLAN
FLOOR DRAIN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
CONC SLAB,
SEE PLAN
NOTES:
1. SET UP DRAIN AS REQUIRED TO RECEIVE
SHOWER STALL. SEE ARCH DRAWINGS.
2. SEE ARCH AND MECH DRAWINGS FOR SIZE AND
LOCATION OF FLOOR DRAINS.
FDCL
2"
8"
2"
2x4 KEY
CONC SLAB,
SEE PLAN
FF EL
SEE PLAN
VAPOR BARRIER
CAPILLARY
WATER BARRIER
D S
EE
P
LA
N
D /3
SCHED
SEE LAP
SPLICE
COL
LINE
1/2"x9"x9" STL PL w/ (4)
1/2" ⌀ EXP ANCHORS,
MIN 4" EMBED. 4-BOLT
GROUP TO RESIST
SHEAR OF 3,000 LBS
COL BRG EL
SEE SCHED
1/4 EQ EQ
9"
EQ
EQ
9"
CL COLUMN
TY
P
1/
2"
TYP
1 1/2"
SEE NOTE 1
#4@16" OC, EW,
2" CLR TOP
COMPONENT TO BE
SUPPORTED
3/4" CHAMFER, TYP
FINISHED GRADE
(2) #4 CONT, 3" CLR
6"
8" M
IN
" M
IN
45.00°
6"6"
" M
IN
NOTES:
1. COORDINATE WITH ELECTRICAL DRAWINGS FOR PLAN DIMENSIONS AND LOCATION OF
PADS
2. STRUCTURAL FILL NOT SUSCEPTIBLE TO FROST: UNDISTURBED GRANULAR SOILS OR FILL
MATERIAL WITH LESS THAN 6% OF MASS PASSING A #200 (0.074mm) MESH SIEVE IN
ACCORDANCE WITH ASTM D422 AND OTHER APPROVED NON-FROST SUSCEPTIBLE
MATERIALS SHALL BE CONSIDERED NON-FROST SUSCEPTIBLE. CLASSIFICATION OF FROST
SUSCEPTIBILITY OF SOIL SHALL BE DETERMINED BY A SOILS OR GEOTECHNICAL
ENGINEER, UNLESS OTHERWISE APPROVED. BEARING PRESSURE OF FILL TO MEET OR
EXCEED 1500 psf.
3. DESIGN AND SPECIFICATION OF THE SIZE, NUMBER, TYPE, AND LOCATION OF COMPONENT
ANCHORAGE IS THE SOLE RESPONSIBILITY OF THE EQUIPMENT MANUFACTURER.
4. EQUIPMENT BASE SHALL BE INSTALLED LEVEL UNLESS INDICATED OTHERWISE.
5. IF NON-SHRINK GROUT IS RECOMMENDED BY THE MANUFACTURER TO SUPPORT THE
GENERATOR, WEDGES, SHIMS, OR LEVELING NUTS SHALL BE USED TO SUPPORT THE
BASE WHILE THE NON-SHRINK GROUT IS PLACED. WEDGES OR SHIMS THAT ARE LEFT IN
PLACE SHALL NOT BE EXPOSED TO VIEW.
STRUCTURAL FILL NOT
SUSCEPTIBLE TO FROST
UNDISTURBED EARTH
(2) #4 CONT, 3" CLR
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
3/
/2
9:
:4
AM
S-501
BLDG 10
TY
PI
C
AL
D
ET
AI
LS
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
C
. G
IB
B S
B.
R
EN
N
ER
R
AM
S U
R
EN
D R
EN
D . D
IC
KE
Y
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: NTSS-501
TYPICAL SLAB REPLACEMENT1
SCALE: NTSS-501
TYPICAL FLOOR DRAIN DETAIL3
SCALE: NTSS-501
TYPICAL SHOWER STALL FLOOR DRAIN DETAIL4
SCALE: NTSS-501
SLAB CONSTRUCTION JOINT (CJ) DETAIL2
SCALE: NTSS-501
TYPICAL BASEPLATE DETAIL5
SCALE: NTSS-501
EXTERIOR PAD FOUNDATION DETAIL6
3/15/2024
BK
R
D D
W
2Q R
B0
4_
Pl an s-
8' - 0"CEILING TAG HEIGHT A.F.F.
010-I-XXXXDOOR TAG DOOR NUMBER
ROOM NAMEROOM TAG
ROOM NUMBER
P01PARTITION TAG PARTITION TYPE
15' - 0"EXPOSED SLAB
TAG
HEIGHT TO UNDERSIDE OF SLAB
THIS HATCH PATTERN IS USED ON PLANS TO
DENOTE AREAS OF THE EXISTING BUILDING THAT
ARE NOT INVOLVED IN THE SCOPE OF WORK.
WALL MOUNTED
FIRE EXTINGUISHER
ACT ACOUSTICAL CEILING TILE
AFF ABOVE FINISHED FLOOR
ALUM ALUMINUM
APPROX APPROXIMATELY
BD BOARD
BOT BOTTOM
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CONC CONCRETE
COL COLUMN
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DIA DIAMETER
DIM DIMENSION(S)
DWG DRAWING
EA EACH
ELEC ELECTRICAL
EQ EQUAL
ABBREVIATIONS
ETR EXISTING TO REMAIN
EXIST EXISTING
FEC FIRE EXTINGUISHER CABINET
FFE FURNITURE, FIXTURES & EQUIPMENT
FLR FLOOR
FND FOUNDATION
GWB GYPSUM WALLBOARD
GYP GYPSUM
HM HOLLOW METAL
HVAC HEATING, VENTILATING & AIR CONDITIONING
ILO IN LIEU OF
INSUL INSULATION / INSULATED
LAV LAVATORY
MANU. MANUFACTURER
MAX MAXIMUM
MECH MECHANICAL
MIN MINIMUM
MTL METAL
NIC NOT IN CONTRACT
NO NUMBER
OC ON CENTER
OPP OPPOSITE / OPPOSITE HAND
PLUMB PLUMBING
PNT PAINT
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
SCWD SOLID CORE WOOD DOOR
SD SMOKE DETECTOR
SPEC SPECIFIED / SPECIFICATION
STC SOUND TRANSMISSION CLASS
STN STAIN FINISH
STRUCT STRUCTURAL
TELE TELEPHONE
TLT TOILET
TO TOP OF
TOC TOP OF CONCRETE
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
W/ WITH
WD WOOD
XXXX
SYMBOL LEGEND
X
INTERIOR
ELEVATION
SHEET NUMBER (WHERE SHOWN)
VIEW NUMBER
XXXX
X
SHEET NUMBER (WHERE SHOWN)
VIEW NUMBER
SECTION
ELEVATION LEVEL
0' - 0"
LEVEL NAME
LEVEL
ELEVATION
SPOT
ELEVATION 1' - 0"
KEYNOTE X
XXXX
X SHEET NUMBER (WHERE SHOWN)
VIEW NUMBER
CALL OUT
XXXX
X
VIEW TITLE
VIEW NAME
SCALE: 1/8" = 1'
VIEW NUMBER
SHEET NUMBER (WHERE CUT)
REVISIONS
X
REVISION
CLOUD
REVISION
NUMBER
X
DEMO WORKNEW WORK
EXISTING TO
REMAIN
WALL
DOOR
FFE
EXISTING TO BE
DEMOLISHED
NEW WORK
PHASING LEGEND
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:0
AM
A-001
BLDG 10
AB
BR
EV
IA
TI
O
N S, L
EG
EN
D
A N
D G
EN
ER
AL
N
O
TE
S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
GENERAL NOTES
1 VERIFY ALL SURROUNDINGS AND CONCEALED ITEMS
PRIOR TO DEMOLITION. ALL ITEMS DAMAGED DURING
DEMOLITION THAT ARE TO REMAIN, SALVAGED AND
RETURNED TO GOVERNMENT WILL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO BE REPLACED
TO ITS ORIGINAL STATE.
2 DIMENSIONS FOR METAL STUD/GYPSUM BOARD WALLS
AND PARTITIONS ARE FROM FACE OF STUD TO FACE OF
STUD.
3 TYPICAL DOORS IN STUD WALLS SHALL BE 4" FROM
NEAREST WALL UNLESS OTHERWISE INDICATED.
4 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS PRIOR TO PERFORMING NEW
CONSTRUCTION.
5 CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
SAFETY AND CLEANLINESS. DUST MUST BE SWEPT UP
AND DEBRIS MUST BE REMOVED AT THE END OF EACH
DAY.
6 REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR EACH DISCIPLINES DEMOLITION EXTENTS
AND NOTES
7 CONTRACTOR SHALL PATCH, REPAIR, AND PAINT, AS
NECESSARY, ALL AREAS DAMAGED DURING DEMOLITION
IN PREPARATION FOR NEW CONSTRUCTION.
8 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND EXTENTS PRIOR TO COMMENCING WITH
DEMOLITION. WHERE REMOVAL OF EXISTING
CONSTRUCTION IMPACTS NEW WORK, COORDINATE
DEMOLITION WITH NEW WORK.
9 THESE DRAWINGS ESTABLISH THE DESIGN INTENT AND
DIMENSIONAL RELATIONSHIPS. DO NOT SCALE
DRAWINGS. CONTRACTOR TO FIELD VERIFY ALL
DIMENSIONS AND EXISTING CONDITIONS PRIOR TO
CONSTRUCTION. ANY OMISSIONS, DISCREPANCIES, OR
CONFLICTS MUST BE REPORTED TO THE
ARCHITECT/ENGINEER IMMEDIATELY UPON DISCOVERY.
10 PROVIDE FIRE RETARDANT TREATED SOLID WOOD
BLOCKING IN WALL BEHIND ALL ACCESSORIES AND
MIRRORS FOR MOUNTING.
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:5
AM
AS-100
BLDG 10
AR
C
H
IT
EC
TU
R
AL
S
IT
E
PL
AN
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SHEET KEYNOTES
1 DSCC FIRE STATION
2 DSCC MAIN GATE; ENTRANCE FOR CONSTRUCTION
WORKERS; ALWAYS OPEN
3 E BROAD STREET GATE (PEDESTRIAN ONLY)
4 PROPOSED PRIMARY CONTRACTOR LAYDOWN YARD
5 PRIMARY TRUCK ENTRANCE, JAMES RD GATE
6 WORK LOCATION
7 PROPOSED SECONDARY CONTRACTOR LAYDOWN YARD
8 USACE OFFICE
PROPOSED PRIMARY HAUL ROUTE
GENERAL SHEET NOTES
1 PRIMARY TRUCK ENTRANCE, JAMES ROAD
GATE, HOURS OF OPERATION ARE 0700-1500
(INBOUND); 0700-1630 (OUTBOUND). IF JAMES
ROAD IS CLOSED THEN MAIN GATE MAY BE
USED FOR TRUCKS ON TEMPORARY BASIS
WITH APPROVAL
2 WAREHOUSE SPACE IN SECTION 9 IS ALSO
AVAILABLE TO CONTRACTOR FOR ADDITIONAL
PROPOSED LAYDOWN AREA
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
1000B
1000A
1106A
1106B
1120 1121
100310041005
11051106
JIHGF
EDCBA
1028 1024
SECTION 9 SECTION 10 SECTION 11
THIS HATCH PATTERN IS USED ON PLANS TO
DENOTE AREAS OF THE EXISTING BUILDING THAT
ARE NOT INVOLVED IN THE SCOPE OF WORK.
KEYPLAN
SECTION 10 SECTION 11
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:2
AM
AE110
BLDG 10
EX
IS
TI
N
G F
LO
O
R P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
EXISTING FLOOR PLAN
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
4 4
3 3 3
3 3 3 3
3 3 3
3 4
AD401
A1
AD402
D2
AD401
H1
JIHGF
EDCBA
7 7
7 7
SECTION 10 SECTION 11
TYP.
TYP.
1000B
1000A
1106A
1106B
11051106
1028 1024
KEYPLAN
SECTION 10 SECTION 11
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:4
AM
AD110
BLDG 10
D E
M O
LI
TI
O N
F
LO
O R
P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
DEMOLITION FLOOR PLAN
GENERAL SHEET NOTES
1 VERIFY ALL SURROUNDINGS AND CONCEALED ITEMS
PRIOR TO DEMOLITION. ALL ITEMS DAMAGED DURING
DEMOLITION THAT ARE TO REMAIN, SALVAGED AND
RETURNED TO GOVERNMENT WILL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO BE REPLACED
TO ITS ORIGINAL STATE.
2 REFER TO SHEET A-001 FOR PHASING LEGEND.
3 CONTRACTOR IS RESPONSIBLE FOR MAINTAINING
SAFETY AND CLEANLINESS. DUST MUST BE SWEPT UP
AND DEBRIS MUST BE REMOVED AT THE END OF EACH
DAY.
4 CONTRACTOR SHALL PATCH, REPAIR, AND PAINT, AS
NECESSARY, ALL AREAS DAMAGED DURING DEMOLITION
IN PREPARATION FOR NEW CONSTRUCTION.
5 CONTRACTOR SHALL FIELD VERIFY ALL EXISTING
CONDITIONS AND EXTENTS PRIOR TO COMMENCING WITH
DEMOLITION. WHERE REMOVAL OF EXISTING
CONSTRUCTION IMPACTS NEW WORK, COORDINATE
DEMOLITION WITH NEW WORK.
6 COORDINATE SLAB DEMOLITION WITH STRUCTURAL
DRAWINGS. IN AREAS WHERE SLAB SAW CUTS GO BELOW
EXISTING WALLS, CONTRACTOR TO REMOVE AND
REPLACE WALL AS NEEDED. ANY PATCH AND REPAIR
NEEDS TO MATCH ADJACENT SURFACES.
SHEET KEYNOTES
1 REMOVE DOOR, HARDWARE AND FRAME IN ITS ENTIRETY
UNLESS NOTED OTHERWISE
2 EXISTING TENANT SPACE TO REMAIN.
3 REMOVE FLOORING
4 REMOVE FLOOR TILE, TOILET FIXTURES, LAVS,
COUNTERS, PARTITIONS, AND ACCESSORIES IN THEIR
ENTIRETY UNLESS NOTED OTHERWISE
5 REMOVE PORTION OF WALL IN PREPARATION FOR NEW
DOOR
6 REMOVE WALL IN ITS ENTIRETY UNLESS NOTED
OTHERWISE
7 REMOVE THE WALL IN ITS ENTIRETY WITH THE
EXCEPTION OF STUDS
8 EXISTING EXPOSED STEEL COLUMN, TYPICAL
9 EXISTING COLUMN ENCLOSURE, TYPICAL
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
EDCBA
9' - 0"
SECTION 10 SECTION 11
TYP1
1000B
1000A
1106A
1106B
11051106
1028 1024
DEMOLITION CEILING LEGEND
REMOVE EXISTING 2X4 LIGHT FIXTURE
REMOVE EXISTING 2X4 ACT AND GRID
REMOVE EXISTING SUPPLY DIFFUSER
REMOVE EXISTING EMERGENCY EGRESS
WALLPACK OR REMOTE HEAD LIGHT
REMOVE EXISTING EXIT LIGHT
REMOVE EXISTING DUAL EXIT LIGHT
REMOVE EXISTING RETURN GRILLE
REMOVE EXISTING DUCT
REMOVE EXISTING 2X2 LIGHT FIXTURE
KEYPLAN
SECTION 10 SECTION 11
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:1
AM
AD111
BLDG 10
D
EM
O
LI
TI
O
N C
EI
LI
N G
P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
DEMOLITION CEILING PLAN
GENERAL SHEET NOTES
1 REMOVE CEILING AND GRID IN ITS ENTIRETY. ALL CEILING
MOUNTED DEVICES TO BE REMOVED AS WELL. SEE
MECHANICAL, ELECTRICAL, AND LIFE SAFETY / FIRE
PROTECTION DRAWINGS FOR ADDITIONAL INFORMATION.
2 EXISTING CEILING HEIGHTS ARE APPROXIMATELY 9'-0".
CONTRACTOR TO FIELD VERIFY EXISTING CEILING
HEIGHT(S).
SHEET KEYNOTES
1 EXISTING HATCH AND GWB SOFFIT TO REMAIN (TYP).
2 DEMOLISH EXISTING HATCH AND GWB SOFFIT.
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
EDCBA
1 1
7 7
7 7
7 7
5 555
TYP.
TYP.
3' - 4" 1' - 0" 3' - 4"
8' - 0 3/4" 7' - 2 3/4" 19' - 11 3/4"2' - 8" 3' - 4"
2' - 5 1/2"
14' - 0"
EDC
1' - 10"
2 2
1' - 1"
1' - 10 1/2"
10041005
1000B
10271028 1024
4' 02' 8' 12'4'
GRAPHIC SCALE: 1/4"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:1
AM
AD401
BLDG 10
D E
M O
LI
TI
O N
E N
LA
R
G
ED
P
LA
N S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/4" = 1'-0"AD110
DEMOLITION ENLARGED PLANA1
SCALE: 1/4" = 1'-0"AD110
DEMOLITION ENLARGED PLANH1
SHEET KEYNOTES
1 REMOVE DOOR IN ITS ENTIRETY
2 REMOVE FLOORING
3 REMOVE MIRROR
4 REMOVE FLOOR TILE
5 REMOVE PORTION OF WALL IN PREPARATION FOR NEW
DOOR, APPROXIMATELY 28 SQ FT
6 REMOVE LAVATORY AND COUNTERTOPS ENTIRELY
7 REMOVE TOILET PARTITIONS AND ALL TOILET
ACCESSORIES COMPLETELY
8 REMOVE WALL IN ITS ENTIRETY
9 REMOVE PORTION OF WALL IN PREPARATION FOR NEW
STOREFRONT
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
4'
0"
JIHGF
3 3 3 3
3 3 3
3 2
6 6
6 6
TYP 4
7 7
7 7 7 7
9' - 0 1/4"
21' - 1 1/2"
3'
1/
4"
89 9
2'
1/
4"
1106A
1106B
1120 1121
4' 02' 8' 12'4'
GRAPHIC SCALE: 1/4"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:1
AM
AD402
BLDG 10
D E
M O
LI
TI
O N
E N
LA
R
G
ED
P
LA
N S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/4" = 1'-0"AD110
DEMOLITION ENLARGED PLAND2
SHEET KEYNOTES
1 REMOVE ELECTRICAL WATER COOLER
2 REMOVE FLOOR TILE
3 REMOVE FLOORING
4 REMOVE LAVATORY AND LAVATORY COUNTERTOPS
ENTIRELY
5 REMOVE PORTION OF WALL IN PREPARATION FOR NEW
DOOR, APPROXIMATELY 28 SQ FT
6 REMOVE DRYWALL FINISH FROM EXISTING METAL STUD
FRAMED WALLS.
7 REMOVE TOILET PARTITIONS AND ALL TOILET
ACCESSORIES COMPLETELY
8 REMOVE WALL IN ITS ENTIRETY
9 REMOVE DOOR IN ITS ENTIRETY
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
1"
41' - 1"
WOMEN'S
RESTROOM
MEN'S
RESTROOM
JANITOR'S
CLOSET
NURSING
1005B
MEN'S LOCKER
ROOM
1004A
JANITOR'S
CLOSET
WOMEN'S
LOCKER ROOM
1001A
CLASSROOM
1001B
CONFERENCE
ROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1106A
OFFICE
1106B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
MOCK MARINES
RECRUITING
OFFICE
11024
OFFICE
OFFICE
OFFICE
1004B
UTILITY ROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
IT WORKSHOP
IT OFFICE SPACE
SERVER ROOM
1005A
MEN'S
RESTROOM
WOMEN'S
RESTROOM
1002A
WOMEN'S
SHOWERS1005C
MEN'S SHOWERS
1000D
STORAGE
22' - 0 1/2"
A-401 A1
A-401 H1
A-403 H1
A-404 A1
A-404 A11
A-403 A1
OPEN OFFICE
AREA
1000A
OPEN OFFICE
AREA
OPEN OFFICE
AREA
1000B
CORRIDOR
A-405 A1
A-405 J1
9'
1/
4"
8'
3/
4"
JIHGF
1000C
OPEN OFFICE
AREA
EDCBA
SECTION 10 SECTION 11
ALIGN
A-402 A1
A-402 H1
ROOM
ROOM
3 3
2 7
KEYPLAN
SECTION 10 SECTION 11
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:5
AM
A-110
BLDG 10
FL
O
O R
P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
FLOOR PLAN
SHEET KEYNOTES
1 EXISTING SERVER ROOM, NIC
2 PROVIDE ZINC COATED STEEL, 12'-0" TALL SECURITY
FENCING AND GATES FOR LOCKABLE STORAGE AREA.
CONTRACTOR TO INSTALL FENCE ATTACHED TO THE
INSIDE FACE OF COLUMNS.
3 WALL MOUNTED FIRE EXTINGUISHER
4 PATCH AND REPAIR EXTERIOR WALL WHERE AN EXISTING
EXHAUST FAN AND ASSOCIATED DUCT WERE REMOVED.
SEE MECHANICAL DRAWINGS.
5 SEE ELECTRICAL SHEETS FOR WORK IN THIS AREA
6 10 EXISTING PAIRS OF DOORS TO REMAIN. DOORS,
FRAMES AND HARDWARE ARE TO REMAIN. DOORS AND
FRAMES ARE TO BE PREPPED AND PAINTED ON THE SIDE
OCCURRING WITHIN THE LIMITS OF WORK
7 CONTRACTOR TO PROVIDE DRAFT CURTAIN IN THIS
SPACE. SHEET METAL DRAFT CURTAIN TO EXTEND DOWN
FROM ACT CEILING MIN. 18"
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
SS
SS
JIHGF
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1106A
OFFICE
1106B
OFFICE
OFFICE
OFFICE 1121
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
AREA
MOCK MARINES
RECRUITING
OFFICE1028
OFFICE
WOMEN'S
RESTROOM
MEN'S
RESTROOM
JANITOR'S
CLOSET
NURSING
1005B
MEN'S LOCKER
ROOM 1004A
JANITOR'S
CLOSET
WOMEN'S
LOCKER ROOM
1001A
CLASSROOM
1001B
CONFERENCE
ROOM
OFFICE
OFFICE
1004B
UTILITY ROOM
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
IT WORKSHOP
IT OFFICE SPACE
SERVER ROOM
1005A
MEN'S
RESTROOM
WOMEN'S
RESTROOM
1002A
WOMEN'S
SHOWERS
1005C
MEN'S SHOWERS
1000D
STORAGE
OPEN OFFICE
AREA
OPEN OFFICE
AREA
1000B
CORRIDOR
1000C
OPEN OFFICE
AREA 1025
OFFICE
A-406 J1
A-406 A1
EDCBA
SECTION 10 SECTION 11
ROOM
ROOM10' - 0"
10' - 0"
LEGEND
GYPSUM BOARD (PAINTED)
2'-0" X 4'-0" ACT @ +/- 9'-0" AFF. NEW CEILING
GRID TO BE ATTACHED TO WALLS .
CONTRACTOR TO VERIFY FINAL CEILING
HEIGHT IN FIELD.
FOR ROOMS 1005C, 1005A, 1004B, 1004A, 1003,
1002A, 1106, 1115, 1105
2X4 LIGHT FIXTURE
SUPPLY DIFFUSER
EXIT SIGN
DOWN LIGHT
EXHAUST FAN
2X4 EMERGENCY LIGHT FIXTURE
EMERGENCY DOWN LIGHT
SUPPLY DIFFUSER
RETURN GRILLE
9' - 0" CEILING TAG
HEIGHT A.F.F.
KEYPLAN
SECTION 10 SECTION 11
GRAPHIC SCALE:
16' 08' 32' 48'16'
1/16"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
:3 9:
A
M
A-111
BLDG 10
C E
IL
IN
G P
LA
N
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/16" = 1'-0"
REFLECTED CEILING PLAN
GENERAL SHEET NOTES
1 REFER TO MECHANICAL AND ELECTRICAL DRAWINGS
FOR LIGHTING AND MECHANICAL FIXTURES.
2 REFER TO SPECIFICATIONS FOR ACCESS PANEL
REQUIREMENTS IN CEILINGS.
3 METAL STUD FRAMING FOR GYPSUM BOARD CEILINGS
SHALL BE SPACED AT 24" O.C.
4 CONTRACTOR TO CENTER SPRINKLER HEADS IN MIDDLE
OF CEILING TILE TO GREATEST EXTENT POSSIBLE.
SHEET KEYNOTES
1 EXISTING HATCH AND GWB SOFFIT TO REMAIN (TYP).
CONTRACTOR TO ATTACH CEILING GRIDS TO SOFFITS.
2 PROVIDE HATCH AND GWB SOFFIT. CONTRACTOR TO
ATTACH CEILING GRIDS TO SOFFITS.
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
1005B
MEN'S LOCKER
ROOM
1000D
STORAGE
1005C
MEN'S SHOWERS
1005A
MEN'S
RESTROOM
1004A
JANITOR'S
CLOSET
1004B
UTILITY ROOM
WOMEN'S
RESTROOM
1002A
WOMEN'S
SHOWERS
WOMEN'S
LOCKER ROOM
11 1/2"
010-I-1004A
0-
I-1
4B 010-I-1002A
10' - 0 3/4" 8' - 1 1/4" 8" 18' - 7 3/4" 5' - 5" 7' - 1 3/4" 12' - 0 1/2" 8' - 0 1/4" 9' - 10"
4'
3/
4"
6'
1/
4" 3'
3/ 4"
3'
3/
4"
4'
8" 3'
5"
3'
5" 5'
3/
4"
P13A
20' - 1 3/4" 8' - 8 1/2"
2' - 8"
11' - 4 1/2" 6' - 0 1/2" 1' - 3" 11' - 10 3/4" 0" 17' - 10"
010-I-1005C
EDCBA
2' - 1"
2'
3/
4"
3'
1/
4" 3'
0"
3'
1/
4"
5'
3/
4" 3'
5"
3'
5" 5'
3/ 4"
3' - 6 1/4"
A-411 C7
1'
9"
1' - 6"
4"
3'
8"
5' - 3 3/4"
2' - 3 3/4" 5' - 1 3/4" 4' - 3 1/2" 2' - 0"
010-I-1003
2'
4'
0"
3' - 6 1/4"
010-I-1000D 010-I-1005B 010-I-1005A 010-I-1002
4' - 9 3/4"
C
LE
AR
5'
0"
C
LE
AR
5'
0"
1' - 8" 5' - 0 1/4" 4' - 4 1/4"
4' - 9 3/4"
CLEAR
2' - 6"
CLEAR
2' - 6"
4' - 9 3/4"
CLEAR
2' - 9 1/2"
CLEAR
2' - 9 1/2"
4'
0"
P12
P26
P12C
P12C
P12C
P12B
P26
P12BP12B
P12
P12A
P12B
P12C
P13A
P13A
P12C
P12B
P12F
P12BP13AP13A
P13A
P12C
P12B
P12F
P13
P13P13
P12B
P12
P12B
P12F
P12C
P12C
CLEAR
3' - 0"
CLEAR
3' - 0" 5' - 3 3/4"
5'
1/
2"
5'
1/
2" 3'
1"
3'
1" 3'
1"
3'
1/
2"
P26
P12B
P26 P26
P26
P13A
/4
5' - 1 1/4"
3'
3/
4" 3'
0"
3'
0"
3'
1/
2" 3'
1"
3'
1"
WOMEN'S
RESTROOM
JANITOR'S
CLOSET
MEN'S
RESTROOM
NURSING
010-I-1106 010-I-1116
8' - 1 1/4" 9' - 6 3/4" 8' - 1 1/4" 7' - 11 3/4"
2'
1/
2"
1'
/2
12' - 0 1/2" 1' - 7 1/4" 9' - 8 1/2" 10' - 0 3/4"
6'
3/
4"
2'
3/
4"
2'
1/
2"
7'
1/
2"
JI
5' - 0 1/2" 1"
5' - 0"
2' - 4"
A-411 C1
5' - 0"
7'
3/
4"
1'
/4
5'
3" 2'
3/ 4" 010-I-1105
010-I-1115
3'
1/
4" 3'
1/ 2"
A-412 A7 2' - 2"
CLEAR
4' - 0"
1' - 0"
P13A
P12B
P12B
P12B P13A
P26 P26
P13A
P12B
P13AP13A
P13A
P13A
P13A
P12
P12B
3'
1/
2" 3'
1"
3'
1" 5'
1/ 2"
5'
1/
2" 3'
1"
P13A
P12B
P13A
CLEAR
4' - 0"
4' 02' 8' 12'4'
GRAPHIC SCALE: 1/4"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
:4 0:
A
M
A-401
BLDG 10
EN
LA
R G
ED
P
LA
N
S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/4" = 1'-0"A-110
ENLARGED PLANSA1
SCALE: 1/4" = 1'-0"A-110
ENLARGED PLANSH1
GENERAL SHEET NOTES
1 REFER TO FINISH SCHEDULE ON SHEET I-601.
2 REFER TO SPECIAL ITEMS SCHEDULE ON SHEET I-602
FOR TOILET PARTITION, COUNTER TOP FINISHES,
LOCKERS AND BENCHES.
3 ALL DIMENSIONS ARE MEASURED TO FACE OF STUD ON
PLANS AND FACE OF GYPSUM BOARD OR FACE OF TILE
ON WALLS IN RESTROOMS AND SHOWERS.
4 SLOPE FLOORS TO DRAIN WHERE SPECIFICALLY NOTED
ON PLANS. REFER TO PLUMBING DRAWINGS.
03/15/2024
R
C JBM
C
W
2Q R
B0
4_
Pl an s-
A-410
A-410 H8H1
A-410 L8
A-410
L1
B1E1
EDCBA
1005B
MEN'S LOCKER
ROOM
1000D
STORAGE
1005C
MEN'S SHOWERS
1005A
MEN'S
RESTROOM
1004A
JANITOR'S
CLOSET
1004B
UTILITY ROOM
WOMEN'S
RESTROOM
1002A
WOMEN'S
SHOWERS
WOMEN'S
LOCKER ROOM
4 4
08 09
4"
02 02
07,13
07,13
10 10
A-411L1 L7 A-411H7
A-420
B2
H1
JI
WOMEN'S
RESTROOM
JANITOR'S
CLOSET
MEN'S
RESTROOM
NURSING
6 7
4 4 33
10 10
2' - 2"
05 05
4' 02' 8' 12'4'
GRAPHIC SCALE: 1/4"GRAPHIC SCALE: = 1'-0"
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
Pl ot
D at e:
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
US Army Corps of Engineers ®
R
AM
S U
R E
N D
R
EN
3/
/2
9:
:5
AM
A-402
BLDG 10
EN
LA
R G
ED
P
LA
N
S
C O
LU
M
BU
S, O H
D
SC
C B
U
IL
D
IN
G
U
SM
C
O
FF
IC
E
R
EN
O
VA
TI
O
N P2
F Y:
M
. C
LA
R K
R . C
LA
R
K
J.
B
LE
H
M
AR
C H
6, W
2Q R
-1 9-
D -0
C
ER
TI
FI
ED
F
IN
AL
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
LO
U
IS
VI
LL
E, K
EN
TU
C
KY
SCALE: 1/4" = 1'-0"A-110
ENLARGED PLANSA1
SCALE:…
This is the start of the file's text. The full file is on GovTribe.