W912QR23R0034_PLANS-0001.pdf

PDF 2 MB Posted

Attached to
Alpena ANG Hangar and Maintenance Shops, MI
Solicitation number
W912QR23R0034
Issued by

About this file

This document package includes federal construction plans and specifications for the Alpena ANG Hangar and Maintenance Shops project, as well as the corresponding solicitation opportunity on FedBizOpps. The plans detail electrical power and lighting requirements for the construction of a new aircraft hangar and maintenance facility, including power and lighting plans for the hangar bay and various support areas. Key equipment includes HVAC units, exhaust fans, emergency generators, and aircraft maintenance equipment. The solicitation seeks design-build proposals for the project, which is estimated to cost between $10-20 million. Offerors must be registered in SAM and comply with various CCR/ORCA requirements. A site visit is available per FAR 52.236-27 Alt I. The contracting officer point of contact is provided. The project requires compliance with HUBZone price evaluation preferences per FAR 19.1307.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

NOT FOR

CONSTRUCTION

1 1312111098765432

A

B

C

D

E

F

G

H

I

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

U S

A C

E L

O U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

M A

R C

H

A L P

E N

A C

R T

C A

L P

E N

A M

IC

H

IG

A

N

R E

P L A

C E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E H

A N

G A

R A

N D

S H

O P

S

P N

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

J K

L

IN

G

C

U s e rs

\d ri d le y \O n e D ri v e

B u rn s

M c D o n n e ll\

D o c u m e n ts

\1 E

C e n tr a l-

R V

T d ri d le y b u rn s m c d .c o m

.r v t

/2

/2

:4

:5

A

M

EL601

L

IG

H T

IN

G

F

IX

T U

R E

S C

H E

D U

L E

D R

ID

L E

Y

R T

A N

N E

H

IL

L

S .S

T R

A T

T O

N

LIGHT FIXTURE SCHEDULE

TYPE

LAMP INFORMATION FIXTURE INFORMATION

TYPE COLOR TEMP

VOLTAG

E

FIXTURE

LUMENS LOAD DESCRIPTION MOUNTING

D1 LED 3500 K 277 V 1500 lm 21 VA 6" RECESSED DOWNLIGHT WITH MEDIUM WIDE DISTRIBUTION, SPECULAR REFLECTOR, WHITE TRIM RING. WHERE

FIXTURE IS INDICATED AS

EMERGENCY ON PLANS, PROVIDE WITH STANDARD 10 WATT EMERGENCY BATTERY DRIVER.

CEILING, RECESSED

E1 LED 277 V 5 VA LED EXIT SIGN, WHITE WITH RED LETTERS, PROVIDE WITH MINIMUM 90 MINUTE BATTERY BACKUP, WIRE UNSWITCHED. CEILING OR WALL, SURFACE, AS INDICATED

ON DRAWINGS

M1 MH 4000 K 277 V 104654 lm 982 VA EXTERIOR LIGHT FIXTURE WITH NARROW BEAM HORIZONTAL LAMP, REMOTE BALLAST SYSTEM. PROVIDE WITH TOP

AND SIDE SHIELDS.

WALL, MOUNT SUCH THAT THERE IS 6"

BETWEEN TOP OF DOOR FRAME AND

BOTTOM OF LIGHT FIXTURE, TILT ANGLE OF

15 DEGREES UON

O1 QUARTZ 120 V 5 VA FAA MODEL L-810 DUAL RED OBSTRUCTION LIGHT FIXTURE. ROOF

T1 LED 3500 K 277 V 30000 lm 222 VA 4' LOW-PROFILE HIGH BAY OPEN INDUSTRIAL FIXTURE WITH HIGHLY REFLECTIVE WHITE POWDERCOATED REFLECTOR. WHERE FIXTURE IS INDICATED AS EMERGENCY ON PLANS, PROVIDE WITH STANDARD

10 WATT EMERGENCY BATTERY DRIVER.

CHAIN

T2 LED 3500 K 277 V 4000 lm 29 VA 1' X 4' STANDARD LED INDUSTRIAL FIXTURE WITH HIGHLY REFLECTIVE WHITE POWERCOATED REFLECTOR. WHERE

FIXTURE IS INDICATED AS

EMERGENCY ON PLANS, PROVIDE WITH STANDARD 10 WATT EMERGENCY BATTERY DRIVER.

CHAIN

T3 LED 3500 K 277 V 4600 lm 35 VA 1' X 4' STANDARD LED STRIP INDUSTRIAL FIXTURE. PROVIDE WITH ANTI-BUG COVER WALL MOUNTED

W1 LED 4000 K 277 V 5400 lm 60 VA 4' WALL MOUNTED CORNER LIGHT, WHITE FLAT ALUMINUM FINISH, FROSTED ACRYLIC SHIELD. WHERE FIXTURE IS INDICATED AS EMERGENCY ON PLANS, PROVIDE WITH STANDARD 10 WATT EMERGENCY BATTERY DRIVER.

SURFACE

Y1 LED 4000 K 277 V 2005 lm 24 VA 18" EXTERIOR ARCHITECTURAL WALL SCONCE WITH TYPE II DISTRIBUTION, DARK BRONZE FINISH AND MINIMUM 90

MINUTE BATTERY BACKUP.

WALL MOUNTED

Y2 LED 3500 K 277 V 8300 lm 82 VA 30' POLE MOUNTED FIXTURE WITH TYPE IV DISTRIBUTION POLE MOUNTED

Y3 LED 3500 K 277 V 2005 lm 24 VA 9" EXTERIOR ARCHITECTURAL WALL SCONCE, DARK BRONZE FINISH AND MINIMUM 90 MINUTE BATTERY BACKUP. WALL MOUNTED

Y4 LED 3000 K 120 V 960 lm 12 VA INDOOR/OUTDOOR PENDANT FEATURES A CLEARLY DEFINED ORB GENTLY ENCIRCLING A CYLINDER OF OPAL GLASS

WITH A BLACK FINISH.

PENDANT

GENERAL NOTES:

1. FIXTURES SELECTED WERE USED AS A

BASIS OF DESIGN. IF CONTRACTOR

SELECTS DIFFERENT FIXTURES, THEN THE

CONTRACTOR MUST SUBMIT A LIGHT

DESIGN SUBMITTAL FOR GOVERNMENT

APPROVAL TO ENSURE THAT ILLUMINANCE

REQUIREMENTS ARE MET PER THE

CURRENT EDITION OF UFC 3-530-01. THE

CONTRACTOR SHALL FAMILIARIZE

THEMSELVES WITH ALL ASPECTS AND

REQUIREMENTS OF THE CONTRACT

DOCUMENTS AND PROVIDE FIXTURES

THAT MEET THOSE REQUIREMENTS.

A

M D

T

/2 /2

06/21/2023

W

2Q R

R

_P

LA

N S-

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

E

E

E

M

M M

J

J

J

M

J

E

M

A

B

C

D

E

F

N

M2

T2 L2

HANGAR BAY

270V DC

M2-8,10,12

400 HZ

M2-14,16,18

L2-1

GFI

WPIU

L2-1

GFI

WPIU

HVLSF-102

M2-37,39,41

MAU-102

M2-25,27,29

EF-102

M2-13,15,17

L2-5

L2-7

L2-13

GFI

WPIU

L2-13

GFI

WPIU

L2-13

GFI

WPIU

L2-13

GFI

WPIU

L2-15

GFI

WPIU

L2-15

GFI

WPIU

L2-15

GFI

WPIU

M2-19,21,23 200A

A.5

VP-01

M2-20,22,24

L2-23 L2-23 L2-23

L2-25

L2-25

L2-25

MTS

L2-17

L2-19

HANGAR DOOR

CONTROL PANEL

PORTABLE

GENERATOR

CONNECTION

H1-2,4,6

H1-1,3,5

TAIL DOOR

CONTROL PANEL

H1

OHD-101A

M2-26,28,30

1. REFER TO SHEETS E-001 AND E-002

FOR ABBREVIATIONS, LEGEND, AND

GENERAL NOTES.

2. ALL ELECTRICAL WORK IN HAZARDOUS

AREAS SHALL BE PER NC WHERE

WORK IS BEING PERFORMED.

3. REFER TO E-011 FOR HAZARDOUS

LOCATION CLASSIFICATION.

4. HANGAR BAY SHALL BE CONSIDERED A

WET LOCATION.

5. PROVIDE ELECTRICAL CONNECTIONS

TO MECHANICAL EQUIPMENT PER

SHEET EP601

6. ALL RECEPTACLES IN HANGAR BAY

SHALL BE MOUNTED AT 48" AFF, UPON.

7. ALL NEWMAN 5-20R RECEPTACLES IN

HANGAR BAY SHALL BE GFI, WEATHER

RESISTANT AND MOUNTED IN A

WEATHERPROOF BOX.

8. PROVIDE JOINTS FOR UTILITIES

BETWEEN THE METAL BUILDING

SYSTEM AND THE LOAD BEARING

MASONRY STRUCTURE TO

ACCOMMODATE PLUS OR MINUS 2

INCHES OF LATERAL MOVEMENT IN ANY

DIRECTION.

GENERAL NOTES:

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

NOT FOR

CONSTRUCTION

1 1312111098765432

A

B

C

D

E

F

G

H

I

N

A

KEYPLAN

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

U S

A C

E L

O U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

M A

R C

H

A L P

E N

A C

R T

C A

L P

E N

A M

IC

H

IG

A

N

R E

P L A

C E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E H

A N

G A

R A

N D

S H

O P

S

P N

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

J K

L

IN

G

C

U s e rs

\d ri d le y \O n e D ri v e

B u rn s

M c D o n n e ll\

D o c u m e n ts

\1 E

C e n tr a l-

R V

T d ri d le y b u rn s m c d .c o m

.r v t

/2

/2

:4

:5

A

M

EP101

P O

W E

R P

L A

N

A R

E A

A

D R

ID

L E

Y

R T

A N

N E

H

IL

L

S .S

T R

A T

T O

N

N

0 4' 8' 16'

MATCHLINE SEE SHEET EP102 FOR CONTINUATION

SCALE: 1/8" = 1'-0"A1

POWER PLAN - AREA A

KEYED NOTES:

ELECTRICAL CONNECTION FOR HVLSF

CONTROL PANEL.

ELECTRICAL CONNECTION FOR VP

CONTROL PANEL.

ELECTRICAL CONNECTION FOR EYEWASH

STATION.

PROVIDE 18" HOUSE KEEPING PAD FOR

ELECTRICAL EQUIPMENT.

MOUNTED ON ELEVATED PLATFORM.

30 AMP, 600V, FUSED AT 10 AMPS, NEMA 1

DISCONNECT.

PROVIDE WALL MOUNTED RACK FOR

CABLE MANAGEMENT.

A

M D

T

/2 /2

06/21/2023

W

2Q R

R

_P

LA

N S-

M

M

E

E

M

M

M

M

M

M

J

J

J

J

J

M

J

J

J

J

J

E

J

J

E

J

G

H

J

K

L

400 HZ

MDP-5

270V DC

MDP-6

L1A-9

L1A-3 L1A-7

L1A-1

GFI

WPIU

L1A-3L1A-7

L1A-9

L1A-9 L1A-13

GFI

AC

L1A-15

L1A-17

GFI

AC

L1A-17

GFI

ACL1A-39

GFI

WPIU

L1A-35

GFI

AC

L1A-35

GFI

AC

L1A-1

GFI

WPIU

L1A-8

L1A-20

GFI

WPIU

L1A-8

L1A-8

L1A-39

GFI

WPIU

EF-101

M2-7,9,11

HANGAR BAY

MULTI-PURPOSE

JAN

WOMEN'S TOILET

MEN'S TOILET

MECH

COMM

FIRE

PROTECTION

ELEC

HVLSF-101

M1-8,10,12

E1

EP401

A1

EP401

MAU-101

M1-31,33,35

A1

EP102

L1B-14

L2-11

L2-1

GFI

WPIU

L2-1

GFI

WPIU

L1A-20

GFI

WPIU

L1A-39

GFI

WPIU

M1-13,15,17 200A

SF-101

M1-19,21,23

EF-103

L2-3

UH-102

L1B-9

CU-101

L1B-33,35

CU-102

L1B-19,21

Q

R

L.5

M

A6

EP401

VP-02

M1-37,39,41

L1B-15

L1B-15

L1B-15

L1B-39L1B-39L1B-39

L1A-11

L1A-5

L1B-41

L1A-7

L1B-8

FA1-7

FA1-5

FA1-1 FA1-3

JPC

M1-20,22,24

L1A-21

L1A-19

FPC

L1B-16

H

L1A-14

L1A-12

L1A-14

L1A-14

SECURE ROOM

L1A-12

L1A-22

L1A-22

L1A-24

1. REFER TO SHEETS E-001 AND E-002

FOR ABBREVIATIONS, LEGEND, AND

GENERAL NOTES.

2. ALL ELECTRICAL WORK IN HAZARDOUS

AREAS SHALL BE PER NC WHERE

WORK IS BEING PERFORMED.

3. REFER TO E-011 FOR HAZARDOUS

LOCATION CLASSIFICATION.

4. HANGAR BAY SHALL BE CONSIDERED A

WET LOCATION.

5. PROVIDE ELECTRICAL CONNECTIONS

TO MECHANICAL EQUIPMENT PER

SHEET EP601

6. ALL RECEPTACLES IN HANGAR BAY

SHALL BE MOUNTED AT 48" AFF, UPON.

7. ALL NEWMAN 5-20R RECEPTACLES IN

HANGAR BAY SHALL BE GFI, WEATHER

RESISTANT AND MOUNTED IN A

WEATHERPROOF BOX.

8. PROVIDE JOINTS FOR UTILITIES

BETWEEN THE METAL BUILDING

SYSTEM AND THE LOAD BEARING

MASONRY STRUCTURE TO

ACCOMMODATE PLUS OR MINUS 2

INCHES OF LATERAL MOVEMENT IN ANY

DIRECTION.

GENERAL NOTES:

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

NOT FOR

CONSTRUCTION

1 1312111098765432

A

B

C

D

E

F

G

H

I

N

A

KEYPLAN

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

U S

A C

E L

O U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

E N

T U

C K

Y

B U

R N

S A

N D

M c D

O N

N E

L L

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

M A

R C

H

A L P

E N

A C

R T

C A

L P

E N

A M

IC

H

IG

A

N

R E

P L A

C E

A

IR

C R

A F

T M

A

IN

T E

N A

N C

E H

A N

G A

R A

N D

S H

O P

S

P N

C E

R T

IF

IE

D F

IN

A

L D

E S

IG

N

S U

B M

IT

T

A L

J K

L

IN

G

C

U s e rs

\d ri d le y \O n e D ri v e

B u rn s

M c D o n n e ll\

D o c u m e n ts

\1 E

C e n tr a l-

R V

T d ri d le y b u rn s m c d .c o m

.r v t

/2

/2

:4

:5

A

M

EP102

P O

W E

R P

L A

N

A R

E A

B

D R

ID

L E

Y

R T

A N

N E

H

IL

L

S .S

T R

A T

T O

N

N

0 4' 8' 16'

MACHINE SEE SHEET EP101 FOR CONTINUATION

SCALE: 1/8" = 1'-0"A6

POWER PLAN - AREA B

PORTABLE

GENERATOR

CONNECTION

SCALE: 1/8" = 1'-0"A1

POWER PLAN - OPTION

N

0 4' 8' 16'

KEYED NOTES:

EMERGENCY EXTERIOR DOOR CONTROL

PUSH BUTTON. ENCLOSURE SHALL BE

LOCKABLE.

ELECTRICAL CONNECTION FOR HOVELS

CONTROL PANEL.

ELECTRICAL CONNECTION FOR VP

CONTROL PANEL.

ELECTRICAL CONNECTION FOR EYEWASH

STATION.

PROVIDE 18" HOUSE KEEPING PAD FOR

ELECTRICAL EQUIPMENT.

ELECTRICAL CONNECTION FOR

DIVERSION VALVE PANEL.

ELECTRICAL CONNECTION FOR

OIL/WATER SEPARATOR CONTROL PANEL.

MOUNTED ON ELEVATED PLATFORM.

RECEPTACLES AND CONDUIT IN ROOM

SHALL BE SURFACE MOUNTED.

RECEPTACLES SHALL BE SURFACES

MOUNTED IF BID OPTION IS AWARDED.

CONNECTION FOR SECURITYCABINET.

COORDINATE FINAL LOCATION WITH

BASE.

PROVIDE WALL MOUNTED RACK FOR

CABLE MANAGEMENT.

6 7

A

M D

T

/2 /2

06/21/2023

W

2Q R

R

_P

LA

N S-

Sheets
EL601 - LIGHTING FIXTURE SCHEDULE
EP101 - POWER PLAN - AREA A
EP102 - POWER PLAN - AREA B

File details come from the government source that posted it. Updated .