W912QR23B0005_CUI_Plans-0001.pdf

PDF 5 MB Posted

Attached to
Youngstown Air Reserve Station (YARS) Construction of New Main Gate
Solicitation number
W912QR23B0005_
Issued by

About this file

This document package contains construction plans and specifications for the Youngstown Air Reserve Station in Ohio. The project involves relocating the main gate and includes construction of a new visitor center, inspection delivery facility, gate house, canopy, and overwatch facility. The plans cover civil site work, structural, architectural, fire protection, plumbing, mechanical, electrical, telecommunications, and landscaping aspects of the project. Construction will require site demolition, grading, paving, utility installation, and erection of the various buildings shown on the plans. Bidders should follow all instructions and notes provided in the design submittal package and comply with the requirements therein for successful completion of the project.

The related federal contract opportunity is a solicitation issued by the Department of the Army Corps of Engineers Engineering District Louisville seeking offers for the construction services defined in the design package. Offerors should review all documents thoroughly to prepare their proposals due by the specified closing date.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CUI

ATTENTION

Use this space to indicate categories, limited dissemination controls, special instructions, points of contact, etc., if needed.

ATTENTION

All individuals handling this information are required to protect it from unauthorized disclosure.

Handling, storage, reproduction, and disposition of the attached document(s) must be in accordance with 32 CFR Part 2002 and applicable agency policy.

Access to and dissemination of Controlled Unclassified Information shall be allowed as necessary and permissible to any individual(s), organization(s), or grouping(s) of users, provided such access or dissemination is consistent with or in furtherance of a Lawful Government Purpose and in a manner consistent with applicable law, regulations, and Government-wide policies.

Standard Form 901 (11-18) Prescribed by GSA/ISOO | 32 CFR 2002

CUI

Certified Final

W

2Q R

B0

5_

C U

I_ Pl an s-

TITLESHEET ID. FILENAME TITLESHEET ID. FILENAME

AN

SI

D

M

AY

FI

LE

N

AM

E:

C

AT

EG

O

R Y

C O

D E

XX

X-

XX

-X

X

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

L O

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G , J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

R

AL

EI

G

H , N

C

-3

(9

1-

(9

)8

-7

FA

X

LI

C

EN

SE

F -0

C

ER

TI

FI

ED

F

IN

AL

D

ES

IG

N

S U

BM

IT

TA

L

YO

U

N G

ST

O

W N

A

IR

R

ES

ER

VE

S

TA

TI

O

N , O

H

IO

R

EL

O C

AT

E

M

AI

N G

AT

E

P2

8, P N

Z

Q

EL

5-

, F Y2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

ED

U

N C

LA

SS

IF

IE

D

IN

FO

R

M

AT

IO

N

(C U

I)

M .P

O E

R .B

LA

IR

M .B

EN

N

ET

L.

O

SE

G

U

ED

A

CIVIL

VF100 VF100.DWG OVERALL EXISTING CONDITIONS SURVEY

VF101 VF101.DWG EXISTING CONDITIONS SURVEY

VF102 VF102.DWG EXISTING CONDITIONS SURVEY

B-101 B-101.DWG SOIL TEST BORING LOCATIONS

B-102 B-102.DWG SOIL TEST BORING LOCATIONS

B-301 B-301.DWG SOIL TEST BORING LOGS

B-302 B-302,DWG SOIL TEST BORING LOGS

C-100 C-100.DWG CIVIL LEGEND AND ABBREVIATIONS

CD101 CD101.DWG SITE DEMOLITION PLAN

CD102 CD102.DWG SITE DEMOLITION PLAN

CS100 CS100.DWG OVERALL CIVIL SITE PLAN

CS101 CS101.DWG ENLARGED CIVIL SITE PLAN

CS102 CS102.DWG ENLARGED CIVIL SITE PLAN

CP101 CP101.DWG ENLARGED ROADWAY LAYOUT PLAN AND CURVE TABLE

CP102 CP102.DWG ENLARGED ROADWAY LAYOUT PLAN AND CURVE TABLE

CP103 CP103.DWG ENLARGED CONCRETE PAVEMENT JOINTING PLAN

CP104 CP104.DWG ENLARGED CONCRETE PAVEMENT JOINTING PLAN

CG100 CG100.DWG OVERALL GRADING AND DRAINAGE PLAN

CG101 CG101.DWG ENLARGED GRADING AND DRAINAGE PLAN

CG102 CG102.DWG ENLARGED GRADING AND DRAINAGE PLAN

CG103 CG103.DWG STORM WATER DETENTION BASIN

CG104 CG104.DWG SEDIMENT AND EROSION CONTROL DETAILS

CG105 CG105.DWG SEDIMENT AND EROSION CONTROL DETAILS

CG106 CG106.DWG OVERALL SEDIMENT AND EROSION CONTROL PLAN

CG107 CG107.DWG ENLARGED SEDIMENT AND EROSION CONTROL PLAN

CG108 CG108.DWG ENLARGED SEDIMENT AND EROSION CONTROL PLAN

CG109 CG109.DWG ROADWAY PROFILES

CG110 CG110.DWG ROADWAY PROFILES

CU100 CU100.DWG OVERALL SITE UTILITIES PLAN

CU101 CU101.DWG ENLARGED SITE UTILITIES PLAN

CU102 CU102.DWG ENLARGED SITE UTILITIES PLAN

CU301 CU301.DWG SANITARY DRAIN PROFILES

CU302 CU302.DWG WATER LINE PROFILES

CU303 CU303.DWG STORM DRAIN PROFILES

C-501 C-501.DWG ENLARGED SIGNAGE AND PAVEMENT MARKING PLAN

C-502 C-502.DWG ENLARGED SIGNAGE AND PAVEMENT MARKING PLAN

C-503 C-503.DWG ENLARGED ROADWAY INTERSECTION AND ISLAND PLANS

C-504 C-504.DWG ENLARGED ROADWAY INTERSECTION AND ISLAND PLANS

C-505 C-505.DWG ENLARGED ROADWAY INTERSECTION AND ISLAND PLANS

C-506 C-506.DWG SITE CIVIL DETAILS

C-507 C-507.DWG SITE CIVIL DETAILS

C-508 C-508.DWG SITE CIVIL DETAIL - AVB

C-509 C-509.DWG SITE CIVIL DETAILS - FENCING

C-510 C-510.DWG SITE CIVIL DETAILS - FENCING

C-511 C-511.DWG SITE CIVIL DETAILS - FENCING

C-512 C-512.DWG SITE CIVIL DETAILS - FENCING

C-513 C-513.DWG SITE CIVIL DETAILS - FENCING

C-514 C-514.DWG SITE CIVIL DETAILS - FENCING

C-515 C-515.DWG SITE CIVIL DETAILS - FENCING

C-516 C-516.DWG SITE CIVIL DETAILS - FENCING

C-517 C-517.DWG SITE UTILITY DETAILS

C-518 C-518.DWG SITE UTILITY DETAILS

C-519 C-519.DWG SITE UTILITY DETAILS

C-520 C-520.DWG SITE UTILITY DETAILS

GENERAL

G-001 G-001.DWG COVER SHEET

G-002 G-002.DWG INDEX OF DRAWINGS

G-003 G-003.DWG CANTONMENT MAP AND PROJECT LOCATION MAP

G-004 G-004.DWG GENERAL CONSTRUCTION NOTES

TITLEFILENAMESHEET ID.

LANDSCAPE

L-101 L-101.DWG OVERALL LANDSCAPE PLAN AND GENERAL NOTES

L-102 L-102.DWG ENLARGED LANDSCAPE PLAN AND DETAILS - ENTRY

L-103 L-103.DWG ENLARGED LANDSCAPE PLAN AND DETAILS - GATE HOUSE AREA

L-104 L-104.DWG ENLARGED LANDSCAPE PLAN AND DETAILS - VISITOR CENTER

L-501 L-501.DWG LANDSCAPE DETAILS

L-502 L-502.DWG ENLARGED ENTRY SIGN DETAIL

STRUCTURAL

(TYPICAL SHEETS)

S-001 S-001.DWG GENERAL NOTES

S-002 S-002.DWG DESIGN DATA

S-003 S-003.DWG IBC INSPECTION TABLES

S-004 S-004.DWG IBC INSPECTION TABLES

S-501 S-501.DWG TYPICAL FOUNDATION DETAILS

S-502 S-502.DWG TYPICAL CMU DETAILS

S-503 S-503.DWG TYPICAL CMU LINTEL DETAILS

S-521 S-521.DWG GATE HOUSE AND CANOPY SECTIONS AND DETAILS

VISITOR CENTER

S-101 S-101.DWG VISITOR CENTER FOUNDATION PLAN

S-102 S-102.DWG VISITOR CENTER ROOF FRAMING PLAN

S-504 S-504.DWG VISITOR CENTER SECTION AND DETAILS

INSPECTION DELIVERY FACILITY

S-111 S-111.DWG INSPECTION DELIVERY FACILITY FOUNDATION PLAN

S-511 S-511.DWG INSPECTION DELIVERY FACILITY DETAILS

GATE HOUSE AND CANOPY

S-121 S-121.DWG GATE HOUSE AND CANOPY FOUNDATION PLAN

OVERWATCH FACILITY

S-131 S-131.DWG OVERWATCH FACILITY FOUNDATION PLAN AND SECTION

LIFE SAFETY

LS001 LS001.DWG VISITOR CENTER - LIFE SAFETY ANALYSIS

LS002 LS002.DWG FIRE PROTECTION SITE PLAN

LS011 LS011.DWG INSPECTION DELIVERY FACILITY - LIFE SAFETY ANALYSIS

LS101 LS101.DWG VISITOR CENTER - FIRST FLOOR LIFE SAFETY PLAN

LS111 LS111.DWG INSPECTION DELIVERY FACILITY - FIRST FLOOR PLAN LIFE SAFETY PLAN

ARCHITECTURAL

(TYPICAL SHEETS)

A-001 A-001.DWG LEGENDS & ABBREVIATIONS

A-002 A-002.DWG ARCHITECTURAL CLEARANCES, MOUNTING HEIGHTS, AND STANDARD DETAILS

AE200 AE200.DWG EXTERIOR FINISHES

AE501 AE501.DWG CABINETRY DETAILS

AE502 AE502.DWG CABINETRY DETAILS

AE503 AE503.DWG TYPICAL METAL ROOF DETAILS

AE601 AE601.DWG DOOR SCHEDULE, TYPES AND FRAMES, LOUVER TYPES AND OPENING FLASHING

AE602 AE602.DWG DOOR DETAILS

AE603 AE603.DWG DOOR AND LOUVER DETAILS

AE604 AE604.DWG WINDOW TYPES AND DETAILS

AE701 AE701.DWG WALL SECTIONS AND WALL TYPES

AE702 AE702.DWG HEAD WALL DETAILS AND ENVELOPE INFORMATION

AF601 AF601.DWG ROOM FINISH SCHEDULE

AF602 AF602.DWG INTERIOR FINISH KEY

AG620 AE620.DWG SIGNAGE DETAILS AND SCHEDULES

AG621 AE621.DWG SIGNAGE DETAILS

AG622 AE622.DWG SIGNAGE DETAILS

VISITOR CENTER

A-003 A-003.DWG VISITOR CENTER AIR BARRIER PLAN

AE101 AE101.DWG VISITOR CENTER FLOOR PLAN

AE102 AE102.DWG VISITOR CENTER REFLECTED CEILING PLAN

AE103 AE103.DWG VISITOR CENTER ROOF PLAN

AE201 AE201.DWG VISITOR CENTER EXTERIOR ELEVATIONS

AE301 AE301.DWG VISITOR CENTER BUILDING SECTIONS

AE401 AE401.DWG VISITOR CENTER ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS

AE402 AE402.DWG VISITOR CENTER ENLARGED FLOOR PLAN AND INTERIOR ELEVATIONS

AE900 AE900.DWG VISITOR CENTER ISOMETRIC VIEWS

IF101 IF101.DWG VISITOR CENTER FURNITURE PLAN

INSPECTION DELIVERY FACILITY

A-013 A-013.DWG INSPECTION DELIVERY FACILITY AIR BARRIER PLAN

AE111 AE111.DWG INSPECTION DELIVERY FACILITY FLOOR PLAN

AE112 AE112.DWG INSPECTION DELIVERY FACILITY REFLECTED CEILING PLAN

AE113 AE113.DWG INSPECTION DELIVERY FACILITY ROOF PLAN

AE211 AE211.DWG INSPECTION DELIVERY FACILITY EXTERIOR ELEVATIONS

AE212 AE212.DWG INSPECTION DELIVERY FACILITY EXTERIOR ELEVATIONS

AE311 AE311.DWG INSPECTION DELIVERY FACILITY BUILDING SECTIONS

AE411 AE411.DWG INSPECTION DELIVERY FACILITY ENLARGED FLOOR PLAN AND

INTERIOR ELEVATIONS

AE412 AE412.DWG INSPECTION DELIVERY FACILITY WALL SECTIONS

AE511 AE511.DWG INSPECTION DELIVERY FACILITY MISCELLANEOUS DETAILS

AE512 AE512.DWG INSPECTION DELIVERY FACILITY ROOF DETAILS

AE513 AE513.DWG CATWALK DETAILS

AE910 AE910.DWG INSPECTION DELIVERY FACILITY ISOMETRIC VIEWS

IF111 IF111.DWG INSPECTION DELIVERY FACILITY FURNITURE PLAN

GATE HOUSE AND CANOPY

AE121 AE121.DWG GATE HOUSE AND CANOPY FLOOR AND ROOF PLAN

AE122 AE122.DWG GATE HOUSE AND CANOPY CANOPY ROOF PLAN

AE221 AE221.DWG GATE HOUSE AND CANOPY GATE HOUSE EXTERIOR ELEVATIONS

AE222 AE222.DWG GATE HOUSE AND CANOPY CANOPY ELEVATIONS

AE321 AE321.DWG GATE HOUSE AND CANOPY CANOPY SECTIONS

AE920 AE920.DWG GATE HOUSE AND CANOPY ISOMETRIC VIEWS

IF121 IF121.DWG GATE HOUSE FURNITURE PLAN

OVERWATCH FACILITY

AE131 AE131.DWG OVERWATCH FACILITY FLOOR PLAN, ROOF PLAN AND ISOMETRICS

AE231 AE231.DWG OVERWATCH FACILITY EXTERIOR ELEVATIONS

AE331 AE331.DWG OVERWATCH FACILITY SECTIONS

IF131 IF131.DWG OVERWATCH FACILITY FURNITURE PLAN

FIRE ALARM AND MASS NOTIFICATION

FA001 FA001.DWG FIRE ALARM AND MASS NOTIFICATION NOTES, AND LEGEND

FA101 FA101.DWG VISITOR CENTER - FIRST FLOOR FIRE ALARM/MASS NOTIFICATION PLAN

FA111 FA111.DWG INSPECTION DELIVERY FACILITY - FIRST FLOOR FIRE ALARM / MASS

NOTIFICATION PLAN

FA501 FA501.DWG FIRE ALARM AND MASS NOTIFICATION DETAILS

FA502 FA502.DWG VISITOR CENTER - FIRE ALARM SEQUENCE OF OPERATIONS MATRIX

FA512 FA512.DWG INSPECTION DELIVERY FACILITY - FIRE ALARM SEQUENCE OF OPERATIONS

MATRIX AND RISER DIAGRAM

VISITOR CENTER

PL101 PL101.DWG VISITOR CENTER FLOOR PLAN - WASTE AND WATER PIPING

INSPECTION DELIVERY FACILITY

PL111 PL111.DWG INSPECTION DELIVERY FACILITY FLOOR PLAN - WASTE PIPING

PL112 PL112.DWG INSPECTION DELIVERY FACILITY FLOOR PLAN - WATER PIPING

GATE HOUSE AND CANOPY

PL121 PL121.DWG GATE HOUSE AND CANOPY FLOOR PLAN - PLUMBING

MECHANICAL

(TYPICAL SHEETS)

M-001 M-001.DWG GENERAL NOTES, LEGEND, AND ABBREVIATIONS

M-501 M-501.DWG MECHANICAL DETAILS

M-502 M-502.DWG MECHANICAL DETAILS

M-601 M-601.DWG MECHANICAL SCHEDULES

M-602 M-602.DWG MECHANICAL SCHEDULES

M-801 M-801.DWG MECHANICAL CONTROLS

M-802 M-802.DWG MECHANICAL CONTROLS

VISITOR CENTER

MH101 MH101.DWG VISITOR CENTER FLOOR PLANS - MECHANICAL

MH301 MH301.DWG VISITOR CENTER MECHANICAL SECTIONS

INSPECTION DELIVERY FACILITY

MH111 MH111.DWG INSPECTION DELIVERY FACILITY FLOOR PLANS - MECHANICAL

MH311 MH311.DWG INSPECTION DELIVERY FACILITY MECHANICAL SECTIONS

GATE HOUSE AND CANOPY

MH121 MH121.DWG GATE HOUSE AND CANOPY FLOOR PLAN - MECHANICAL

MH321 MH321.DWG GATE HOUSE AND CANOPY MECHANICAL SECTION

INDEX OF DRAWINGS

ELECTRICAL

(TYPICAL SHEETS)

E-001 E-001.DWG ELECTRICAL LEGEND AND ABBREVIATIONS

ED101 ED101.DWG PARTIAL SITE PLAN ELECTRICAL DEMOLITION

ES101 ES101.DWG PARTIAL SITE PLAN - LIGHTING PHOTOMETRICS

ES102 ES102.DWG PARTIAL SITE PLAN - LIGHTING PHOTOMETRICS

ES103 ES103.DWG PARTIAL SITE PLAN - LIGHTING PHOTOMETRICS

ES104 ES104.DWG PARTIAL SITE PLAN ELECTRICAL LIGHTING

ES105 ES105.DWG PARTIAL SITE PLAN ELECTRICAL LIGHTING

ES106 ES106.DWG PARTIAL SITE PLAN ELECTRICAL LIGHTING

ES107 ES107.DWG PARTIAL SITE PLAN ELECTRICAL POWER

ES108 ES108.DWG PARTIAL SITE PLAN ELECTRICAL POWER

ES109 ES109.DWG PARTIAL SITE PLAN ELECTRICAL LIGHTING AND POWER

ES110 ES110.DWG PARTIAL SITE PLAN ELECTRICAL POWER

E-501 E-501.DWG ELECTRICAL DETAILS

E-502 E-502.DWG ELECTRICAL DETAILS

E-503 E-503.DWG ELECTRICAL DETAILS

E-504 E-504.DWG ELECTRICAL DETAILS

E-505 E-505.DWG ELECTRICAL DETAILS

E-506 E-506.DWG ELECTRICAL DETAILS

E-601 E-601.DWG PANELBOARD SCHEDULES

E-602 E-602.DWG PANELBOARD SCHEDULES

E-701 E-701.DWG POWER RISER DIAGRAM

VISITOR CENTER

EL101 EL101.DWG VISITOR CENTER FLOOR PLAN - ELECTRICAL LIGHTING

EG101 EG101.DWG VISITOR CENTER ROOF PLAN - LIGHTNING PROTECTION

EP101 EP101.DWG VISITOR CENTER FLOOR PLANS - ELECTRICAL POWER

INSPECTION DELIVERY FACILITY

EL111 EL111.DWG INSPECTION DELIVERY FACILITY FLOOR PLAN - ELECTRICAL LIGHTING

EG111 EG111.DWG INSPECTION DELIVERY FACILITY ROOF PLAN - LIGHTNING PROTECTION

EP111 EP111.DWG INSPECTION DELIVERY FACILITY FLOOR PLANS - ELECTRICAL POWER

GATE HOUSE AND CANOPY

EL121 EL121.DWG GATE HOUSE AND CANOPY PLAN - ELECTRICAL LIGHTING

EP121 EP121.DWG GATE HOUSE AND CANOPY PLAN - ELECTRICAL POWER AND

LIGHTNING PROTECTION

OVERWATCH FACILITY

EP131 EP131.DWG OVERWATCH FACILITY PLANS - ELECTRICAL POWER AND

LIGHTNING PROTECTION

TELECOMMUNICATIONS

(TYPICAL SHEETS)

T-001 T-001.DWG TELECOMMUNICATIONS LEGEND AND ABBREVIATIONS

TS101 TS101.DWG PARTIAL SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

TS102 TS102.DWG PARTIAL SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

TS103 TS103.DWG PARTIAL SITE PLAN - TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

T-501 T-501.DWG TELECOMMUNICATIONS DETAILS

T-502 T-502.DWG TELECOMMUNICATIONS RISER DIAGRAMS

T-601 T-601.DWG SECURITY AND CCTV RISER DIAGRAMS

VISITOR CENTER

TN101 TN101.DWG VISITOR CENTER FLOOR PLAN - TELECOMMUNICATIONS

AND SECURITY

INSPECTION DELIVERY FACILITY

TN111 TN111.DWG INSPECTION DELIVERY FACILITY FLOOR PLAN -

TELECOMMUNICATIONS & SECURITY

GATE HOUSE AND CANOPY

TN121 TN121.DWG GATE HOUSE AND CANOPY FLOOR PLAN -

TELECOMMUNICATIONS AND SECURITY

OVERWATCH FACILITY

TN131 TN131.DWG OVERWATCH FACILITY FLOOR PLAN -

TELECOMMUNICATIONS AND SECURITY G-002

IN

D

EX

O

F D

R

AW

IN

G

S

G -0

.D

W G

PLUMBING

(TYPICAL SHEETS)

P-001 P-001.DWG PLUMBING SYMBOLS, ABBREVIATIONS AND GENERAL NOTES

P-501 P-501.DWG PLUMBING DETAILS

P-502 P-502.DWG PLUMBING DETAILS

P-503 P-503.DWG PLUMBING DETAILS

P-601 P-601.DWG PLUMBING SCHEDULES

P-602 P-602.DWG PLUMBING SCHEDULES

P-901 P-901.DWG WASTE PIPING ISOMETRICS

P-902 P-902.DWG WATER PIPING ISOMETRICS

FIRE SPRINKLER

FX001 FX001.DWG FIRE SPRINKLER GENERAL NOTES, FIRE PUMP GENERAL NOTES, AND LEGENDS

FX101 FX101.DWG VISITOR CENTER - FIRE SPRINKLER FLOOR PLAN

FX111 FX111.DWG INSPECTION DELIVERY FACILITY - FIRE SPRINKLER FLOOR PLAN

FX501 FX501.DWG WET-PIPE SPRINKLER SYSTEM DETAILS

FX502 FX502.DWG ADDITIONAL WET-PIPE SPRINKLER SYSTEM DETAILS

AM

EN

D

M

EN

T

6/

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

W

2Q R

B0

5_

C U

I_ Pl an s-x x x x x xxxxxxxx x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x

Twini ng

R oa d

Navy Drive

H

ER

R

IM

AN

R

O

AD

PER

IM

ETER

R

O

AD

Vandenberg Road

Spaatz Road

Ken ny

R oa d

Stopa Road

F-1416

F-1409

F-9033538

F-6006 N/A

F-6001

F-6009

F-6010

F-9027

F-9027

F-9028

F-9032

F-9027

F-1407

F-2005

F-2005

F-6006

F-6007

N/A N/A

F-1420

F-1417

ARNOLD

R

OAD

HERRIMAN ROAD

FACILITY

TRAINING

FIRE

x x

PERIMITER ROAD

C

AM

P R

O

AD

PERIMITER ROAD

MARINE ROAD

ACCESS CONTROL POINT

LEGEND:

x

YOUNGSTOWN ARS CANTONMENT

SCALE: ~1" = 200'

AN

SI

D

M

AY

FI

LE

N

AM

E:

C

AT

EG

O

R Y

C O

D E

XX

X-

XX

-X

X

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

L O

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G , J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

R

AL

EI

G

H , N

C

-3

(9

1-

(9

) 8

-7

FA

X

LI

C

EN

SE

F -0

C

ER

TI

FI

ED

F

IN

AL

D

ES

IG

N

S U

BM

IT

TA

L

YO

U

N G

ST

O

W N

A

IR

R

ES

ER

VE

S

TA

TI

O

N , O

H

IO

R

EL

O C

AT

E

M

AI

N G

AT

E

P2

8, P N

Z

Q

EL

5-

, F Y2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

ED

U

N C

LA

SS

IF

IE

D

IN

FO

R

M

AT

IO

N

(C U

I)

M . P

O E

R . B

LA

IR

M . B

EN

N

ET

L.

O

SE

G

U

ED

A

PROJECT SITE

AND CONTRACTOR

PROPOSED LAYDOWN AREA

PROPOSED

HAUL ROUTE

BASE CIVIL ENGINEER

BLDG 510

MAIN GATE

ACP

KING GRAVES ROAD

KING GRAVES ROAD

MAJOR ROADS

STREETS

INSTALLATION BOUNDARIES

ACCESS ROUTE

ACP

BUILDING OUTLINE

PERIMETER ROAD

G-003

C

AN

TO

N

M

EN

T M

AP

A

N D

PR

O

JE

C

T

LO

C

AT

IO

N

M

AP

G -0

.D

W G

AM

EN

D

M

EN

T

6/

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

W

2Q R

B0

5_

C U

I_ Pl an s-

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

W

2Q R

B0

5_

C U

I_ Pl an s-

21 3 4

A

B

C

A

A.1A.1

1.6 2.8 4.2

AN

SI

D

M

AY

FI

LE

N

AM

E:

C

AT

EG

O

R Y

C O

D E

XX

X-

XX

-X

X

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

L O

U

IS

VI

LL

E D

IS

TR

IC

T

D R

. M

AR

TI

N

L U

TH

ER

K

IN

G , J

R . P

LA

C

E

LO

U

IS

VI

LL

E, K

EN

TU

C

KY

XX

XX

XX

-X

X- X-

XX

XX

XX

XX

XX

-X

X- X-

XX

XX

JO

NE

S

FR

AN

KL

IN

R

D, S

UI

TE

R

AL

EI

G

H , N

C

-3

(9

1-

(9

)8

-7

FA

X

LI

C

EN

SE

F -0

C

ER

TI

FI

ED

F

IN

AL

D

ES

IG

N

S U

BM

IT

TA

L

YO

U

N G

ST

O

W N

A

IR

R

ES

ER

VE

S

TA

TI

O

N , O

H

IO

R

EL

O C

AT

E

M

AI

N G

AT

E

P2

8, P N

Z

Q

EL

5-

, F Y2

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

SU

BM

IT

TE

D B

Y:

C H

EC

KE

D B

Y:

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

IS

SU

E D

AT

E:

SI

ZE

M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

CONTROLLED UNCLASSIFIED INFORMATION (CUI)

C O

N

TR

O

LL

ED

U

N C

LA

SS

IF

IE

D

IN

FO

R

M

AT

IO

N

(C U

I)

M .P

O E

R .B

LA

IR

M .B

EN

N

ET

L.

O

SE

G

U

ED

A

AE113

ROOF PLAN

1/4" - 1'-0'

PLAN

NORTH

TRUE

NORTH

PRE-FINSHED,

STANDING SEAM,

METAL ROOF

PANELS, TYP

PRE-FINISHED METAL

RIDGE COVER, TYP

PRE-FINISHED METAL

GUTTER, TYP

4"x5" PRE-FINISHED METAL

DOWNSPOUT, TYP. SEE

CIVIL DRAWINGS FOR TIE-IN

TO STORM DRAIN

GENERAL NOTES

1. ALL ROOF SYSTEMS SHALL BE INSTALLED

PER ROOF MANUFACTURER'S PRINTED INSTRUCTION AND

STANDARDS.

2. ALL PLUMBING, MECHANICAL, ELECTRICAL, ETC. ITEMS

MOUNTED ON OR PENETRATING THROUGH ROOF MAY NOT

BE SHOWN. SEE RESPECTIVE MECHANICAL, PLUMBING AND

ELECTRICAL DRAWINGS FOR LOCATIONS. PENETRATIONS

THROUGH ROOF SYSTEM SHALL COMPLY WITH ROOF

MANUFACTURER'S PRINTED INSTRUCTIONS AND

STANDARDS.

3. PROVIDE SNOW GUARDS PER MFR'S RECOMMENDATIONS

OUTSIDE FACE OF

WALL BELOW, TYP

'-7

20'-21

2"

83'-8"

20'-21 2" 20'-21

2" 20'-21 2"

6' -6

1 2"

'-1

0"

'-0

'-5

18'-10"53'-7"11'-31 2"

15'-4"

26'-6"24'-5"11'-2"

9'-9"

4' -0

SL

O

PE

2:

ROOF TOP EQPMT, SEE

MECH DRAWINGS , TYP

TYP LIGHTNING

PROTECTION/AIR

TERMINAL, SEE ELEC

DRAWINGS

PRE-FINISHED METAL

CANOPY BELOW

OUTSIDE FACE OF

WALL BELOW, TYP

7'-4"

AE412

SNOWGUARD, EXTEND 12"

BEYOND DOOR JAMB, TYP

@ EXTERIOR DOORS, UNO

4' -3

1 2"

5'-0"

PRE-FINISHED

METAL CANOPY

BELOW

PRE-FINISHED METAL

CANOPY BELOW

2" VTR

3" VTR

SL

O

PE

2:

SL

O

PE

:1

SL

O

PE

4:

SL

O

PE

4:

SL

O

PE

4:

3" VTR 3" VTR

4" FLUE

GRV-5

GRV-6

AE212

AE212

AE211

AE311

AE311

AE311

AE311

AE412

AE412

AE412

AE511

TYP @

CANOPIES

TYP LIGHTNING

PROTECTION/AIR

TERMINAL, SEE ELEC

DRAWINGS

5" VTR

(2) 4" VTR

AE113

IN

SP

EC

TI

O N

D

EL

IV

ER

Y

FA

C

IL

IT

Y

R O

O F

PL

AN

AE

3.

D

W G

AE503

'-9

A

M

EN

D M

EN

T

- R

EV

IS

E

U

PP

ER

R

O O

F

SL

O

PE

8- 8-

ARIMS: 200A Disposition: Maintain for 15 yrs after construction.

W

2Q R

B0

5_

C U

I_ Pl an s-

2Q R

B0

5_

C U

I_ Pl an s-

2Q R

B0

5_

C U

I_ Pl an s-

2Q R

B0

5_

C U

I_ Pl an s-

2Q R

B0

5_

C U

I_ Pl an s-

Purple CUI Cover
Sheets and Views
G-002
G-003
LS002
AE113
FX101
FX111
FX501
FX502

Fillable_field:

Controlled by: Youngstown Air Reserve Station Controlled by: TBD CUI Category: CTI Distribution/Dissemination Control: Federal Employees and Contractors only /

FEDCON

File details come from the government source that posted it. Updated .