W912QR22R0060_Plans-0007.pdf

PDF 1 MB Posted

Attached to
WPAFB B620 Tower Reno
Solicitation number
W912QR22R0060
Issued by

About this file

This solicitation seeks proposals for the Add/Alter B620 Tower Renovation project at Wright-Patterson Air Force Base in Ohio. The project involves renovating floors and common areas, installing new finishes and equipment, and upgrading building systems. The estimated construction cost is between $5 million and $10 million. The solicitation is a full and open competition under NAICS code 236220 with a size standard of $39.5 million. Proposals are due in accordance with FAR Clause 52.236-27 Alt I. The point of contact for inquiries is the listed contracting specialist.

View the file

Other files

File Type Posted
W912QR22R0060_Plans-0009.pdf PDF
W912QR22R0060_Specs-0009.pdf PDF
W912QR22R0060_Specs-0007.pdf PDF
W912QR22R0060-0006.pdf PDF
W912QR22R0060-0005.pdf PDF
W912QR22R0060-0004.pdf PDF
W912QR22R0060-0003.pdf PDF
W912QR22R0060-0002.pdf PDF
W912QR22R0060-0001.pdf PDF
W912QR22R0060_Plans-0000.pdf PDF
W912QR22R0060_Specs_Vol1-0000.pdf PDF
W912QR22R0060 06.09.22.pdf PDF
W912QR22R0060_Specs_Vol2-0000.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UPUP

A-202

A-301

STAIR

CV-22

ELEVATOR

DB-20

MECHANICAL

SHAFT

CCV-19

TOILET

2DB-24

ELECTRIC

CLOSET

2CW-20

CORRIDOR

2CY-18

PASSAGE

2CY-24

2CY-18

2CY-24

2CZ-19

3' - 4"

CORRIDOR

2-6

3' - 4"

B

B

A-201

A-202

2CW-20

046046

A-401

196196

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:4

P

M

A-103

N E

W W

O R

K P

A R

T

IA

L P

L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

0 2' 4' 8' 1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 2

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN

THIS AREA.

104 NEW ELEVATOR LOBBY DOORS.

105 NEW ELEVATOR LOBBY CALL STATION.

106 NEW ELEVATOR HALL POSITION INDICATOR.

107 NEW FLOOR INDICATOR ON BOTH JAMBS.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT

42" ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

153 NEW SHOTCRETE WALL (SEE STRUCTURAL).

162 INSTALL (2) LAYERS OF 5/8" TYPE X GYPSUM BOARD ON WALL UP

TO UNDERSIDE OF DECK. TAPE AND FINISH. REFER TO FINISH

SCHEDULE FOR MORE INFORMATION.

163 INSTALL SALVAGED MARKER BOARD.

183 INSTALL SOLID SURFACE CAP ABOVE NEW WALL INSTALLATION

WITH 1" OVERHANG. FIELD MEASURE AND PREPARE AS

NECESSARY.

196 WALL FINISH ALIGNS AS INDICATED.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

UP

A-201

A-202

A-201

A-202

LAB

8DA-20

TOILET

8DA-22

ELECTRIC

CLOSET

8CW-20

MECHANICAL

SHAFT

8CV-19

CORRIDOR

8CW-21

ELEVATOR

DB-20

STAIR

CV-22

A-301

47' - 7"

"CLOSET

8CU-26

BALCONY

8CT-18

BALCONY

8DD-26

A-302

A-303

A-511

8DD-26

8CT-18

8CV-22

8CU-26

8CW-21 8DA-22

56' - 8"

4' - 6 1/2" 4' - 6 1/2"

A-611

A-611

A-611

A B C

A B C

A-502

A-501

A-501 3 8

A-501

A-304

7' - 1 1/2"

/4

8CV-19

F

G

8CW-20

B

046046

A-401

DRAWINGS INCLUDE DESCRIPTION OF AN 'ADD ALTERNATE' TO

CONSTRUCT A COMPLETE NEW 8TH FLOOR LEVEL BELOW THE

'BASE BID' NEW 9TH FLOOR LEVEL CONSTRUCTION. THE

CONTRACTOR SHALL SEPERATELY PLAN AND BID THE 'BASE

BID' AND 'ADD ALTERNATE' WORK SCOPE.

ADD ALTERNATE INCLUDES ALL WORK AT THIS FLOOR LEVEL

INCLUDING NEW DOOR 8CW-21, EXCEPT FOR SCOPE NOTED

INSIDE EXISTING STAIR TOWER AT THIS LEVEL. ALL WORK

INSIDE STAIR TOWER CV-22 INCLUDING SCOPE AT 8CV-22,

8CW-20, AND 8CV-19 SHALL BE INCLUDED IN THE "BASE BID".

NOTE: ' ' SPECIFICALLY INDICATES RAILING, WALL, AND DOOR

SCOPE TO BE INCLUDED IN BASE BID.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:5

P

M

A-107

N E

W W

O R

K F

L O

O R

P L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 8

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN THIS

AREA.

104 NEW ELEVATOR LOBBY DOORS.

105 NEW ELEVATOR LOBBY CALL STATION.

106 NEW ELEVATOR HALL POSITION INDICATOR.

107 NEW FLOOR INDICATOR ON BOTH JAMBS.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36" ABOVE

STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT 42"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

116 NEW BALCONY. SEE STRUCTURAL.

117 NEW STAINLESS STEEL RAILING. REFER TO DETAIL ON A-503.

118 FIREMAN'S GATE. REFER TO DETAIL ON A-503.

131 NEW STC 50 SLIDING WINDOWS. ARROW INDICATES DIRECTION OF

TRAVEL. ALL OTHERS ARE FIXED.

142 NEW 10 LB. ABC FIRE EXTINGUISHER. MOUNT 48" AFF TOP OF CABINET.

INSTALL SIGNAGE OVER CABINET.

202 NEW WALL-MOUNTED SIGN HERE TO READ 'LIVE LIMIT LOAD ON THIS

FLOOR 120 PSF'. FONT: HELVETICA MEDIUM (TACTILE RAISED

CHARACTERS TO BE CAPITAL LETTERS). CONFIRM TEXT WITH END USER

PRIOR TO FABRICATION. CONFIRM SIGN LOCATION WITH END USER

PRIOR TO INSTALLATION. BASIS OF DESIGN SIGNAGE TO BE: TAKEFORM,

FUSION. SIGN FINISHES TO BE PER MANUFACTURER'S STANDARD COLOR

OPTIONS.

206 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES OF NEW

EXTERIOR CONCRETE BALCONY SLAB. PREP CONCRETE SURFACE PER

COATING MANUFACTURERS REQUIREMENTS. REFER TO

SPECIFICATIONS.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

F. PROVIDE AND INSTALL WINDOW SHADES AT ALL NEW WINDOWS

(SLIDING AND FIXED) ON LEVEL 8 AND LEVEL 9. SEE SPECIFICATION

SECTION 12 24 13.

P L A

N N

O R

T H

BID ALTERNATE PROJECT SCOPE

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

A-202

A-201

A-202

1LAB

9DA-20

TOILET

9DA-22

ELECTRIC

CLOSET

9CW-20

CORRIDOR

9CW-21

MECHANICAL

SHAFT

9CV-19

ELEVATOR

DB-20

STAIR

CV-22

BALCONY

9DD-26

CLOSET

9CU-26

BALCONY

9CT-18

A-302

A-303

A-511

9DD-26

9CT-18

9CV-22

9CW-21

9DA-22

9CU-26

56' - 8"

9DA-20

B

G H I

D E F

D

G

E

H

F

I

A-501

G

A-502

A-501

A-501

A-304

4' - 6 1/2" 47' - 7" 4' - 6 1/2"

7' - 1 1/2"

9CV-19

9CW-20

046046

A-401

VIF

2' - 3"

V

IF

104 201

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:5

P

M

A-108

N E

W W

O R

K F

L O

O R

P L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 9

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN THIS

AREA.

104 NEW ELEVATOR LOBBY DOORS.

105 NEW ELEVATOR LOBBY CALL STATION.

106 NEW ELEVATOR HALL POSITION INDICATOR.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36" ABOVE

STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT 42"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

116 NEW BALCONY. SEE STRUCTURAL.

131 NEW STC 50 SLIDING WINDOWS. ARROW INDICATES DIRECTION OF

TRAVEL. ALL OTHERS ARE FIXED.

138 HID PROXIMITY CARD READER AND ELECTRIC STRIKE WITH 12V BACKUP

BATTERY STAND ALONE SYSTEM.

142 NEW 10 LB. ABC FIRE EXTINGUISHER. MOUNT 48" AFF TOP OF CABINET.

INSTALL SIGNAGE OVER CABINET.

149 STUD & GYP BOARD DUCT ENCLOSURE. HOLD TIGHT TO DUCT.

201 NEW FLOOR INDICATOR ON INTERIOR SIDE OF SECURITY DOORS.

202 NEW WALL-MOUNTED SIGN HERE TO READ 'LIVE LIMIT LOAD ON THIS

FLOOR 120 PSF'. FONT: HELVETICA MEDIUM (TACTILE RAISED

CHARACTERS TO BE CAPITAL LETTERS). CONFIRM TEXT WITH END USER

PRIOR TO FABRICATION. CONFIRM SIGN LOCATION WITH END USER PRIOR

TO INSTALLATION. BASIS OF DESIGN SIGNAGE TO BE: TAKEFORM, FUSION.

SIGN FINISHES TO BE PER MANUFACTURER'S STANDARD COLOR

OPTIONS.

206 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES OF NEW

EXTERIOR CONCRETE BALCONY SLAB. PREP CONCRETE SURFACE PER

COATING MANUFACTURERS REQUIREMENTS. REFER TO SPECIFICATIONS.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

F. PROVIDE AND INSTALL WINDOW SHADES AT ALL NEW WINDOWS

(SLIDING AND FIXED) ON LEVEL 8 AND LEVEL 9. SEE SPECIFICATION

SECTION 12 24 13.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

A-202

A-201

A-202

LAB

10DA-20

TOILET

10DA-22

ELECTRIC

CLOSET

10CW-20

CORRIDOR

10CW-21

MECHANICAL

SHAFT

10CV-19

ELEVATOR

DB-20

STAIR

CV-22

4' - 6" 47' - 8" 4' - 6"

BALCONY

10CT-18

BALCONY

10DD-26

A-302

A-303

108108

10CV-22

10CW-21

106 10DA-20

B

G

A-502

A-304

56' - 8"

10CY-24

10CY-19

10CV-19

10CW-20

046046

A-401

201206

207207

207207

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:5

P

M

A-109

N E

W W

O R

K F

L O

O R

P L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 10

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN THIS

AREA.

104 NEW ELEVATOR LOBBY DOORS.

106 NEW ELEVATOR HALL POSITION INDICATOR.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36" ABOVE

STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT 42"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

116 NEW BALCONY. SEE STRUCTURAL.

117 NEW STAINLESS STEEL RAILING. REFER TO DETAIL ON A-503.

136 EXISTING WINDOWS AND DOOR TO REMAIN

142 NEW 10 LB. ABC FIRE EXTINGUISHER. MOUNT 48" AFF TOP OF CABINET.

INSTALL SIGNAGE OVER CABINET.

146 ALL HOLES AND ABANDONED DUCT SPACES SHALL BE FIRESTOPPED TO

QUALIFY AS A 2-HOUR PARTITION. NEW ELECTRONIC DEVICES SHALL BE

SURFACE MOUNTED.

147 PATCH CONCRETE WHERE CURB WAS REMOVED AND MAKE SMOOTH

TRANSITION TO NEW BALCONY.

149 STUD & GYP BOARD DUCT ENCLOSURE. HOLD TIGHT TO DUCT.

201 NEW FLOOR INDICATOR ON INTERIOR SIDE OF SECURITY DOORS.

206 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES OF NEW

EXTERIOR CONCRETE BALCONY SLAB. PREP CONCRETE SURFACE PER

COATING MANUFACTURERS REQUIREMENTS. REFER TO SPECIFICATIONS.

207 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES OF

EXISTING EXTERIOR CONCRETE BALCONY SLAB. EXTEND COATING 12" UP

THE VERTICAL FACE OF EXTERIOR CONCRETE GUARD WALL. PREP

CONCRETE SURFACE PER COATING MANUFACTURERS REQUIREMENTS.

REFER TO SPECIFICATIONS.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

A-202

A-201

A-202

LAB

11DA-20

TOILET

11DA-22

ELECTRIC

CLOSET

11CW-20

CORRIDOR

11CW-21

MECHANICAL

SHAFT

11CV-19

ELEVATOR

DB-20

STAIR

CV-22

BALCONY

11CT-18

BALCONY

11DD-26

A-302

A-303

11CV-22

56' - 8"

4' - 6"4' - 6" 47' - 8"

18' - 0"

B

A-502

A-502

A-304

206 206

11CV-19

11CW-20

046046

A-401

207207

207207

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:0

P

M

A-110

N E

W W

O R

K F

L O

O R

P L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 11

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK

WITHIN THIS AREA.

104 NEW ELEVATOR LOBBY DOORS.

105 NEW ELEVATOR LOBBY CALL STATION.

106 NEW ELEVATOR HALL POSITION INDICATOR.

107 NEW FLOOR INDICATOR ON BOTH JAMBS.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC

AT 42" ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

116 NEW BALCONY. SEE STRUCTURAL.

117 NEW STAINLESS STEEL RAILING. REFER TO DETAIL ON A-503.

136 EXISTING WINDOWS AND DOOR TO REMAIN

142 NEW 10 LB. ABC FIRE EXTINGUISHER. MOUNT 48" AFF TOP OF

CABINET. INSTALL SIGNAGE OVER CABINET.

147 PATCH CONCRETE WHERE CURB WAS REMOVED AND MAKE

SMOOTH TRANSITION TO NEW BALCONY.

206 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES

OF NEW EXTERIOR CONCRETE BALCONY SLAB. PREP

CONCRETE SURFACE PER COATING MANUFACTURERS

REQUIREMENTS. REFER TO SPECIFICATIONS.

207 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES

OF EXISTING EXTERIOR CONCRETE BALCONY SLAB. EXTEND

COATING 12" UP THE VERTICAL FACE OF EXTERIOR CONCRETE

GUARD WALL. PREP CONCRETE SURFACE PER COATING

MANUFACTURERS REQUIREMENTS. REFER TO

SPECIFICATIONS.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

UPUP

A-202

LAB

12DA-20

TOILET

12DA-22

ELECTRIC

CLOSET

12CW-20

CORRIDOR

12CW-21

MECHANICAL

SHAFT

12CV-19 ELEVATOR

DB-20

STAIR

CV-22

A-301

BALCONY

12CT-18

BALCONY

12DD-26

A-302

A-303

115 115

115 116

108 108

109 107

12CV-22

18' - 0"

B

A-502

56' - 8"

4' - 6" 47' - 8" 4' - 6"

/3

/3

12CV-19

A-201

A-202

12CW-20

046046

A-401

207207

207207

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:0

P

M

A-111

N E

W W

O R

K F

L O

O R

P L A

N

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - LEVEL 12

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN

THIS AREA.

104 NEW ELEVATOR LOBBY DOORS.

105 NEW ELEVATOR LOBBY CALL STATION.

106 NEW ELEVATOR HALL POSITION INDICATOR.

107 NEW FLOOR INDICATOR ON BOTH JAMBS.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT

42" ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

116 NEW BALCONY. SEE STRUCTURAL.

117 NEW STAINLESS STEEL RAILING. REFER TO DETAIL ON A-503.

136 EXISTING WINDOWS AND DOOR TO REMAIN

142 NEW 10 LB. ABC FIRE EXTINGUISHER. MOUNT 48" AFF TOP OF

CABINET. INSTALL SIGNAGE OVER CABINET.

147 PATCH CONCRETE WHERE CURB WAS REMOVED AND MAKE

SMOOTH TRANSITION TO NEW BALCONY.

206 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES

OF NEW EXTERIOR CONCRETE BALCONY SLAB. PREP

CONCRETE SURFACE PER COATING MANUFACTURERS

REQUIREMENTS. REFER TO SPECIFICATIONS.

207 TRAFFIC COATING TO BE APPLIED TO ALL EXPOSED SURFACES

OF EXISTING EXTERIOR CONCRETE BALCONY SLAB. EXTEND

COATING 12" UP THE VERTICAL FACE OF EXTERIOR CONCRETE

GUARD WALL. PREP CONCRETE SURFACE PER COATING

MANUFACTURERS REQUIREMENTS. REFER TO SPECIFICATIONS.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

A-201

ROOF AREA

13DA-20

ELEVATOR ROOM

13DA-22

CORRIDOR

13CW-21

ELECTRIC

CLOSET

13CW-20

MECHANICAL

SHAFT

13CV-19

ELEVATOR

DB-20

STAIR

CV-22

A-301

A-302

A-303

DN

115115

13CV-22

B

13CV-19

A-202

A-202

13CW-20

046046

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:0

P

M

A-112

N E

W W

O R

K F

L O

O R

P L A

N

R O

O F

L E

V E

L

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1/4" = 1'-0"1

NEW WORK FLOOR PLAN - ROOF LEVEL 13

0 2' 4' 8'

GENERAL NOTES

ARCHITECTURAL KEYNOTES

046 REFER TO MEP DRAWINGS FOR DESCRIPTION OF WORK WITHIN

THIS AREA.

108 NEW STAINLESS STEEL HANDRAIL WITH WALL RETURNS AT 36"

ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

109 NEW STAINLESS STEEL GUARDRAIL WITH SPINDELS AT 4" OC AT

42" ABOVE STAIR NOSING. REFER TO STAIR DETAILS.

115 EXISTING DOOR TO REMAIN.

145 PATCH DAMAGED/DETERIORATED ROOF SURFACE AS MAY BE

REQUIRED. CONTRACTOR TO PROVIDE $5,000 ALLOWANCE FOR

REPAIRS TO EXISTING BASED ON CONDITION PRIOR TO

CONSTRUCTION ACTIVITIES. CONFIRM ACTUAL REPAIR

REQUIREMENTS PRIOR TO CONSTRUCTION.

A. THE FIRST THREE FLOORS OF THIS BUILDING WILL BE OCCUPIED

DURING CONSTRUCTION.

B. LEVELS 9 AND 10 SHALL BE CONSTRUCTED TO MEET ICD/ICS 705

STANDARDS.

C. REFER TO A-605 FOR INFORMATION RELATED TO FINISHES.

D. REFER TO A-601 FOR PARTITION TYPES.

E. PATCH AND REPAIR GYPSUM BOARD AROUND NEW ELEVATOR

DEVICES. PAINT PATCHED AREAS.

P L A

N N

O R

T H

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

LEVEL 8

1075'-0"

LEVEL 9

1086'-6"

LEVEL 10

1098'-0"

LEVEL 11

1109'-6"

LEVEL 12

1121'-0"

LEVEL 13/ROOF

1132'-6"

LEVEL 13 STAIR

1133'-8 1/2"

STAIR ROOF

1142'-8 1/2"

ELEVATOR PENTHOUSE

1149'-5"

ELEVATOR ROOF

1155'-0"

NEW BALCONY SLAB

1120'-4"

NEW BALCONY SLAB

1108'-10"

NEW BALCONY SLAB

1097'-4"

NEW BALCONY SLAB

1086'-5"

NEW BALCONY SLAB

1074'-11"

A-512

A-512

160 160

A-501

0 2' 4' 8' 12'

B

ID

A L T

E R

N A

T E

DRAWINGS INCLUDE DESCRIPTION OF AN 'ADD ALTERNATE' TO

CONSTRUCT A COMPLETE NEW 8TH FLOOR LEVEL BELOW THE

'BASE BID' NEW 9TH FLOOR LEVEL CONSTRUCTION. THE

CONTRACTOR SHALL SEPARATELY PLAN AND BID THE 'BASE

BID' AND 'ADD ALTERNATE' WORK SCOPE.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:1

P

M

A-203

E N

L A

R G

E D

E A

S T

E L E

V A

T

IO

N

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

3/16" = 1'-0"1

ENALRGED EAST ELEVATION

EXTERIOR MATERIALS

SCHEDULE

INSULATED METAL WALL PANEL

BASIS OF DESIGN

CENTRIA FORMAWALL

COLOR: 133 SANDSTONE

ALUMINUM WINDOW FRAME

COLOR: DARK BRONZE

WINDOW GLAZING

ALUMINUM SOFFIT PANEL

BASIS OF DESIGN

CENTRIA 1W-10 PERFORATED PANEL

COLOR: 133 SANDSTONE

EXTERIOR HOLLOW METAL DOORS

PAINT: P-2

EXPOSED CONCRETE

ELASTOMETRIC COATING ON VERTICAL SURFACES TO MATCH

EXISTING CONCRETE AS REQUIRED

TRAFFIC COATING OVER NEW HORIZONTAL CONCRETE WALKWAY

ARCHITECTURAL KEYNOTES

155 NEW STAINLESS STEEL RAILING.

156 NEW METAL PANEL BEAM COVER.

157 EXISTING CONCRETE.

158 NEW INSULATED METAL PANEL.

160 METAL PANEL JOINT.

167 PRE-FINISHED SOFFIT PANEL BOTTOM OF ASSEMBLY.

168 ALUMINUM FRAMED WINDOWS.

169 ALUMINUM SOFFIT PANEL BOTTOM OF ASSEMBLY.

BID ALTERNATE PROJECT SCOPE

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

LEVEL 8

1075'-0"

1" 6 3/4"

1"

4' - 11"

TO FACE OF SHAFT

5' - 0"

TO FACE OF SHAFT

FACE OF

CONCRETE

BALCONY

ABOVE

3' - 10"

TO FACE

OF SHAFT

8 13/16"

1" 4' - 6"

TO FACE OF SHAFT

LEVEL 9

1086'-6"

6 3/4"

1 1/4"

10 5/8"

5" 4' - 6"

TO FACE OF SHAFT

612 2 LAYERS

612 2 LAYERS

619619

EXISTING CONCRETE

BALCONY

1"

3" 3 3/4"

619 619

2 LAYERS

633 1' - 0"

LEVEL 10

1098'-0"

1"

1" 4"

6 3/4"

4' - 6"

TO FACE OF SHAFT

619 621

/4

/2

/4

/4

2 LAYERS

612 2 LAYERS

619619619

2 LAYERS

4' - 6"

TO FACE OF SHAFT

612 2 LAYERS

F

DRAWINGS INCLUDE DESCRIPTION OF AN 'ADD ALTERNATE' TO

CONSTRUCT A COMPLETE NEW 8TH FLOOR LEVEL BELOW THE

'BASE BID' NEW 9TH FLOOR LEVEL CONSTRUCTION. THE

CONTRACTOR SHALL SEPARATELY PLAN AND BID THE 'BASE

BID' AND 'ADD ALTERNATE' WORK SCOPE.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:1

P

M

A-501

W A

L L S

E C

T

IO

N A

N D

D E

T A

IL

S

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1 1/2" = 1'-0"7

LEVEL 8 UNDERSIDE DETAIL

1 1/2" = 1'-0"1

LEVEL 8 CEILING DETAIL

1 1/2" = 1'-0"2

TOP OF PARTITION DETAIL

1 1/2" = 1'-0"5

LEVEL 9 CEILING DETAIL

1 1/2" = 1'-0"4

LEVEL 8 WINDOW DETAIL

0 0.25' 0.5' 1' 1.5' 1 1/2" = 1'-0"3

LEVEL 8, 9 WALL DETAIL

1 1/2" = 1'-0"8

LEVEL 9-WINDOW DETAIL

ARCHITECTURAL KEYNOTES

601 3" INSULATED METAL PANEL

602 EXTRUDED ALUMINUM PANEL EDGE TRIM BY PANEL

MANUFACTURER.

604 MITER BOTTOM OF PANEL AT EAST AND WEST CORNER.

605 2HR SPRAYED FIRE RESISTIVE MATERIAL ON ALL PRIMARY

STRUCTURAL STEEL.

606 R20 SPRAY FOAM INSULATION APPLIED TO BOTTOM OF METAL

DECK, DO NOT APPLY OVER STRUCTURAL STEEL SURFACES

RECEIVING SPAY-ON FIRE RESISTANT MATERIAL.

607 VENTILATED METAL PANEL, CEILING / SOFFIT SYSTEM WITH

CONCEALED FASTENERS AND EDGE TRIM. SOFFIT PANEL

ATTACHMENT TO RESIST MIN ARCHITECTURAL COMPONENT

WINDLOAD PERFORMANCE DEFINED IN DESIGN LOADS OF SHT

S-001.

608 SOFFIT PANEL ATTACHMENT STRUCTURE, 2 1/2" C-STUD FRAMING

(MIN 20 GA, G90 COATING). HORIZONTAL MEMBERS

PERPENDICULAR TO SOFFIT PANELS SPACED MAX 24" OC.

VERTICAL MEMBERS, ATTACHED TO BOTTOM OF PRIMARY FLOOR

STRUCTURE ABOVE, TO LIMIT MAX HORIZONTAL MEMBER SPAN TO

36".

609 3 5/8" (MIN 18GA 1 3/8" FLANGE) AT 16" OC

610 DIAGONAL BRACES @ 48" OC

612 5/8" GYPSUM WALL BOARD

614 3/4" VERTICAL FURRING & AIR CAVITY.

619 BACKER ROD AND SEALANT.

620 10" CONTINUOUS SHEET METAL. FASTEN TO METAL FRAMING T&B.

CENTER ON FLOOR SLAB.

621 WINDOW CONNECTION TO BLAST FRAME BY WINDOW

MANUFACTURER. REFER TO STRUCTURAL DRAWINGS.

622 HORIZONTAL STUD BETWEEN VERTICAL FRAMING. ALIGN TO

BOTTOM OF SLAB.

623 GYPSUM WALL BOARD CEILING SOFFIT. 5/8" GYP BOARD AND 2 1/2"

LIGHT GAUGE FRAMING @ 24" O.O. REFER TO REFLECTED CEILING

PLAN.

624 2 HR RATED JOINT SYSTEM. UL FW.D.1003. MINERAL WOOL

FORMING MATERIAL W/ FILL MATERIAL FLUSH W/ FLOOR SURFACE.

625 2 HR RATED JOINT SYSTEM. UL FW.D.0057. MINERAL WOOL

FORMING MATERIAL W/ FILL MATERIAL SEALANT FLUSH W/ FLOOR

SURFACE.

626 3/4" THICK SOLID SURFACE.

627 BLAST FRAME. REFER TO STRUCTURAL DRAWINGS.

629 WALL ASSEMBLY AS SCHEDULED.

630 WINDOW MULLION AS SPECIFIED

631 SEAL WALL ASSEMBLY AS REQUIRED FOR SPECIFIED WALL

RATINGS.

632 3" Z FURRING AT 24" OC, INSTALLED AROUND OTHER FRAMING.

FASTEN TO BOTTOM OF CONCRETE SLAB. INSTALL 3" DEPTH OF

SPRAY FOAM INSULATION, TRIMMED TO FACE OF 3" FURRING.

INSTALL 5/8 GYPSUM BOARD CEILING OVER INSULATION AS

'THERMAL BARRIER' WITH LEVEL 1 BOARD FINISH. COVERAGE

LIMTED TO CONCRETE SLAB BELOW EXTERIOR BALCONY.

633 DRIP ALONG TOP OF WINDOW ASSEMBLY.

634 PREFINISHED METAL TRIM

0 0.25' 0.5' 1' 1.5'

0 0.25' 0.5' 1' 1.5' 0 0.25' 0.5' 1' 1.5'

0 0.25' 0.5' 1' 1.5'

0 0.25' 0.5' 1' 1.5' 0 0.25' 0.5' 1' 1.5'

3" = 1'-0"6

WALL AT MULLION DETAIL

0 0.125' 0.25' 0.5' 0.75'

BID ALTERNATE PROJECT SCOPE

A. AT LOCATIONS WHERE ACOUSTICAL CEILING GRID OR METAL SOFFIT ABUTS

RIBBED CONCRETE WALL SURFACES, CLEANLY SAWCUT RIBS OFF TO A

HEIGHT OF 2" BELOW THE FINISH CEILING HEIGHT PATCH SURFACE AND

PAINT TO MATCH EXISTING AS REQUIRED TO CREATE SMOOTH FINISHED

CONCRETE.

B. REFER TO FLOOR PLANS FOR DEFINITION OF TRAFFIC COATING APPLIED TO

EXTERIOR BALCONY SURFACES.

GENERAL NOTES

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

LEVEL 11

1109'-6"

8" RETURN

1"

4 1/2"

1"

LEVEL 12

1121'-0"

LEVEL 11 /

1109'-6"

617617

4' - 6"

LEVEL 8

1075'-0"

3' - 9"8" RETURN

4' - 6"

4 1/2"

615 619

608608

1"

A-113

3' - 9"8" RETURN

4' - 6"

LEVEL 9

1086'-6"

4 1/2"

608608

2 LAYER

TOP OF METAL PANEL

9'-4" AFF

1"

8" RETURN

LEVEL 10

1098'-0"

1"

4 1/2"

/8

M C

612 2 LAYERS

615 635

607602

TOP OF METAL PANEL

9'-4" AFF

4' - 6"

639639

DRAWINGS INCLUDE DESCRIPTION OF AN 'ADD ALTERNATE' TO

CONSTRUCT A COMPLETE NEW 8TH FLOOR LEVEL BELOW THE

'BASE BID' NEW 9TH FLOOR LEVEL CONSTRUCTION. THE

CONTRACTOR SHALL SEPARATELY PLAN AND BID THE 'BASE

BID' AND 'ADD ALTERNATE' WORK SCOPE.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:2

P

M

A-502

B A

L C

O N

Y D

E T

A

IL

S

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

1 1/2" = 1'-0"1

BALCONY DETAIL - LEVELS 11, 12

1 1/2" = 1'-0"4

BALCONY DETAIL - LEVEL 8

GENERAL NOTES

A. AT LOCATIONS WHERE ACOUSTICAL CEILING GRID OR METAL SOFFIT ABUTS

RIBBED CONCRETE WALL SURFACES, CLEANLY SAWCUT RIBS OFF TO A

HEIGHT OF 2" BELOW THE FINISH CEILING HEIGHT PATCH SURFACE AND

PAINT TO MATCH EXISTING AS REQUIRED TO CREATE SMOOTH FINISHED

CONCRETE.

B. REFER TO FLOOR PLANS FOR DEFINITION OF TRAFFIC COATING APPLIED TO

EXTERIOR BALCONY SURFACES.

1 1/2" = 1'-0"3

BALCONY DETAIL - LEVEL 9

1 1/2" = 1'-0"2

BALCONY DETAIL - LEVEL 10

0 0.25' 0.5' 1' 1.5'

ARCHITECTURAL KEYNOTES

601 3" INSULATED METAL PANEL

602 EXTRUDED ALUMINUM PANEL EDGE TRIM BY PANEL

MANUFACTURER.

604 MITER BOTTOM OF PANEL AT EAST AND WEST CORNER.

605 2HR SPRAYED FIRE RESISTIVE MATERIAL ON ALL PRIMARY

STRUCTURAL STEEL.

607 VENTILATED METAL PANEL, CEILING / SOFFIT SYSTEM WITH

CONCEALED FASTENERS AND EDGE TRIM. SOFFIT PANEL

ATTACHMENT TO RESIST MIN ARCHITECTURAL COMPONENT

WINDLOAD PERFORMANCE DEFINED IN DESIGN LOADS OF SHT

S-001.

608 SOFFIT PANEL ATTACHMENT STRUCTURE, 2 1/2" C-STUD FRAMING

(MIN 20 GA, G90 COATING). HORIZONTAL MEMBERS

PERPENDICULAR TO SOFFIT PANELS SPACED MAX 24" OC.

VERTICAL MEMBERS, ATTACHED TO BOTTOM OF PRIMARY FLOOR

STRUCTURE ABOVE, TO LIMIT MAX HORIZONTAL MEMBER SPAN TO

36".

609 3 5/8" (MIN 18GA 1 3/8" FLANGE) AT 16" OC

610 DIAGONAL BRACES @ 48" OC

611 5/8" EXTRUDED GLASS MAT GYPSUM SHEATHING.

612 5/8" GYPSUM WALL BOARD

615 CONCRETE BALCONY SLAB WITH ELASTOMERIC COATING

(TRAFFIC COATING) APPLIED TO ALL EXPOSED SURFACES.

616 UNFACED BATT INSULATION FROM TOP STUD CAVITY TO MINIMUM

8" BELOW TOP OF INSULATED METAL WALL PANEL.

617 PRE-FINISHED METAL BEAM COVER TO MATCH INSULATED METAL

PANEL. PROVIDE MISC CONCEALED WALL MOUNTED BRACKETS

FOR ATTACHMENT.

619 BACKER ROD AND SEALANT.

635 SELF LEVELING SEALANT AT BALCONY JOINT.

636 REFER TO PLANS AND CONCRETE REPAIR NOTES ON G-003 FOR

EXISTING CURB REMOVAL AND SLAB REPAIR. ELASTOMERIC

COATING (TRAFFIC COATING) TO BE APPLIED TO ALL EXPOSED

SURFACES.

637 EXISTING CONCRETE STRUCTURE. PROTECT DURING

CONSTRUCTION.

638 PREFINISHED METAL FLASHING

639 INTERIOR PRE-FINISHED METAL BEAM COVER TO MATCH

INSOLATED METAL WALL PANEL. PROVIDE MISC CONCEALED

WALL MOUNTED BRACKETS FOR ATTACHMENT.

0 0.25' 0.5' 1' 1.5'

0 0.25' 0.5' 1' 1.5'0 0.25' 0.5' 1' 1.5' BID ALTERNATE PROJECT SCOPE

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

1. PROVIDE NEW 4" HIGH RUBBER BASE AND PAINT WALL SURFACE AT NEW PARTITION AT NORTH WALL TO MATCH EXISTING ADJACENT FINISH COLORS.

2. PAINT ALL WALLS IN STAIRWELL. AT LEVEL 1, RESINSTALL SALVAGED CARPET AND WALL BASE AT LEVEL 1. REMOVE ALL CARPET AND ADHESIVE AND

SMOOTH EXISTING SLAB TO PROPERLY PREP CONCRETE FOR SEALING ON LEVELS 2 AND 3. PROVIDE SC-1 CONCRETE SEALER AT CONCRETE SUBSTRATE. FLOORING AT ALL OTHER LANDINGS/LEVELS WITHIN STAIRWELL IS EXISTING TO REMAIN (ETR). PAINT EXISTING STAIR RAILINGS P-2 THROUGHOUT STAIRWELL (REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION RELATED TO PAINT TYPE AND COATINGS).

3. PROVIDE 5'-0" CT-1 CERAMIC TILE WAINSCOT WITH CTB-1 AT BASE, AT ALL WALLS. GYPSUM WALL ABOVE WAINSCOT TO BE PAINTED P-1.

4. ESD-1 ELECTROSTATIC DISSIPATIVE FLOORING TO BE INSTALLED OVER EXISTING POLYMERIC POURED FLOOR IN LABS ON LEVEL 10 (ROOM NUMBER 10-1).

INSPECT EXISTING FLOOR PER MANUFACTURERS GUIDELINES PRIOR TO INSTALLATION. ADHERE TO MANUFACTURERS GUIDELINES FOR INSTALLATION.

5. PROVIDE A 5'-0" CT-1 CERAMIC TILE WAINSCOT WITH CTB-1 AT BASE AT SOUTH WALL. PAINT GYPSUM BOARD P-1 ABOVE WAINSCOT. PAINT EXPOSED

GYPSUM BOARD P-1. PAINT EXPOSED GYPSUM BOARD P-1 AT NORTH, EAST, WEST WALLS.

6. SALVAGE AND REUSE EXISTING CEILING TILES.

7. PAINT SOFFITS P-1.

8. REFER TO ELEVATOR SPECIIFICATIONS FOR CAB INTERIOR FINISHES.

9. PROVIDE SOLID SURFACE SS-1 ON WINDOW SILLS PER DETAILS.

ROOM FINISH SCHEDULE NOTES

A. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION RELATED TO FINISHES.

B. FIELD VERIFY EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK.

C. NEW HOLLOW METAL DOORS & FRAMES TO BE PAINTED P-2 U.N.O.

D. ETR= EXISTING TO REMAIN.

E. EXISTING INTERIOR STAIR HANDRAIL TO BE PAINTED P-2 (REFER TO

SPECIFICATIONS FOR ADDITIONAL INFORMATION RELATED TO PAINT TYPE AND

COATINGS). NEW RAILS TO BE STAINLESS STEEL.

F. MANUFATURERS LISTED IN FINISH SCHEDULE ARE USED TO INDICATE A BASIS OF

DESIGN. PRODUCTS WITH EQUAL PHYSICAL PROPERTIES AND COLORS MAY BE

USED. REFER TO SPECIFICATIONS.

G. PROVIDE AND INSTALL WINDOW SHADES AT ALL NEW WINDOWS (SLIDING AND

FIXED) ON LEVEL 8 AND LEVEL 9. SEE SPECIFICATION SECTION 12 24 13.

DRAWINGS INCLUDE DESCRIPTION OF AN 'ADD ALTERNATE' TO

CONSTRUCT A COMPLETE NEW 8TH FLOOR LEVEL BELOW THE

'BASE BID' NEW 9TH FLOOR LEVEL CONSTRUCTION. THE

CONTRACTOR SHALL SEPARATELY PLAN AND BID THE 'BASE

BID' AND 'ADD ALTERNATE' WORK SCOPE.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

P

P R

\c a d d \R e vi t\ -S cr a p \T

O W

E R

S P

A C

E C

N T

R L -R a m a n d a .v ie u .r vt

/2

/2

:2

:2

P

M

A-621

F

IN

IS

H

S C

H E

D U

L E

F

IN

IS

H L

E G

E N

D A

N D

N O

T E

S

W R

IG

H

T -P

A T

T E

R S

O N

A

IR

F O

R C

E B

A S

E O

H L O

U

IS

V

IL

L E

D

IS

T R

IC

T

D

R M

A R

T

IN

L U

T H

E R

K

IN

G J

R P

L

L O

U

IS

V

IL

L E

K

Y

B U

R G

E S

S

N

IP

L E

V

IN

E

S T

S

U

IT

E

C

IN

C

IN

N

A T

I, O

H

S B

IR

K

L E

Y

E L E

W

IS

B

N /H

E A

P Y

J V

L W

O O

D A

R D

/2

/2

P N

O

CERTIFIED FINAL

A D

D T

O W

E R

S P

A C

E

Z H

T V

ROOM FINISH SCHEDULE LEVEL 1

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

1CW-21 CORRIDOR ETR ETR/ RB ETR/ PAINT ETR ETR NOTE 1

1DB-24 TOILET ETR ETR/CTB-1 ETR/CT-1/P-1 P-1 MATCH

EXISTING

NOTE 5

ROOM FINISH SCHEDULE LEVEL 2

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

2-6 CORRIDOR ETR ETR/RB ETR/P-1 ETR ETR NOTE 6

2CY-18 CORRIDOR ETR ETR/RB ETR/ PAINT ETR ETR NOTE 1

2CY-24 PASSAGE ETR ETR/RB ETR/P-1 ETR ETR NOTE 6

2DB-24 TOILET ETR ETR/CTB-1 ETR/ PAINT/CT-1 P-1 MATCH

EXISTING

NOTE 5

ROOM FINISH SCHEDULE LEVEL 3

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

3CW-21 CORRIDOR ETR ETR/ RB ETR/ PAINT ETR ETR NOTE 1

3CX-31 PASSAGE ETR ETR/RB ETR/ PAINT P-1 MATCH

EXISTING

3CX-32 PASSAGE ETR ETR/ RB ETR/ PAINT ACT-1 8'-0"

3DA-20 PASSAGE ETR ETR/ RB ETR/ PAINT ETR ETR

3DB-24 CHASE ETR ETR/CTB-1 ETR/ PAINT/CT-1 P-1 ETR NOTE 5

ROOM FINISH SCHEDULE LEVEL 4

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

4CW-21 CORRIDOR ETR ETR/ RB ETR/ PAINT ETR ETR NOTE 1

ROOM FINISH SCHEDULE LEVEL 5, 6 & 7

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

5CW-21 CORRIDOR ETR ETR/ RB ETR/ PAINT ETR ETR NOTE 1

ROOM FINISH SCHEDULE LEVEL 8

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

8CT-18 BALCONY TFAW N/A N/A N/A N/A

8CU-26 CLOSET ESD-1 RB-1 P-1 ACT-1 8'-4"

8CV-19 MECHANICAL

SHAFT

ETR ETR ETR ETR ETR

8CW-20 ELECTRIC

CLOSET

ETR ETR ETR P-1 8'-0"

8CW-21 CORRIDOR ESD-1 RB-1 P-1 ETR ETR

8DA-20 LAB ESD-1 RB-1 P-1 ACT-1 8'-4" NOTES 7, 9

8DA-22 TOILET PT-1 CTB-1 P-1/CT-1 ACT-1 8'-0" NOTE 3

8DD-26 BALCONY TFAW N/A N/A N/A N/A

ROOM FINISH SCHEDULE LEVEL 9

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

9CT-18 BALCONY TFAW N/A N/A N/A N/A

9CU-26 CLOSET ESD-1 RB-1 P-1 ACT-1 8'-4"

9CV-19 MECHANICAL

SHAFT

ETR ETR ETR ETR ETR

9CW-20 ELECTRIC

CLOSET

ETR ETR ETR P-1 8'-0"

9CW-21 CORRIDOR ESD-1 RB-1 P-1 ETR ETR

9DA-20 LAB ESD-1 RB-1 P-1 ACT-1 8'-4" NOTES 7, 9

9DA-22 TOILET PT-1 CTB-1 P-1/CT-1 ACT-1 8'-0" NOTE 3

9DD-26 BALCONY TFAW N/A N/A N/A N/A

ROOM FINISH SCHEDULE LEVEL 10

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

10CT-18 BALCONY TFAW N/A N/A N/A N/A

10CV-19 MECHANICAL

SHAFT

ETR ETR ETR ETR ETR

10CW-20 ELECTRIC

CLOSET

ETR ETR ETR P-1 8'-0"

10CW-21 CORRIDOR ESD-1 RB-1 P-1 ETR ETR

10DA-20 LAB ESD-1 RB-1 ETR ACT-1 8'-11" NOTE 4

10DA-22 TOILET PT-1 CTB-1 P-1/CT-1 ACT-1 8'-0" NOTE 3

10DD-26 BALCONY TFAW N/A N/A N/A N/A

ROOM FINISH SCHEDULE LEVEL 11

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

11CT-18 BALCONY TFAW N/A N/A N/A N/A

11CV-19 MECHANICAL

SHAFT

ETR ETR ETR ETR ETR

11CW-20 ELECTRIC

CLOSET

ETR ETR ETR P-1 8'-0"

11CW-21 CORRIDOR ETR ETR P-1 ETR ETR

11DA-20 LAB ETR ETR ETR ACT-1 8'-11"

11DA-22 TOILET ETR CTB-1 P-1/CT-1 ACT-1 8'-0" NOTE 5

11DD-26 BALCONY TFAW N/A N/A N/A N/A

ROOM FINISH SCHEDULE LEVEL 12

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

12CT-18 BALCONY TFAW N/A N/A N/A N/A

12CV-19 MECHANICAL

SHAFT

ETR ETR ETR ETR ETR

12CW-20 ELECTRIC

CLOSET

ETR ETR ETR P-1 8'-0"

12CW-21 CORRIDOR ETR ETR P-1 ETR ETR

12DA-20 LAB ETR ETR ETR ACT-1 8'-11"

12DA-22 TOILET ETR CTB-1 P-1/CT-1 ACT-1 8'-0" NOTE 5

12DD-26 BALCONY TFAW N/A N/A N/A N/A

ROOM FINISH SCHEDULE LEVEL 13

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

13CW-21 CORRIDOR ETR ETR/ RB ETR/ PAINT ETR ETR NOTE 1

ROOM FINISH SCHEDULE STAIRS

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

CCV-19 MECHANICAL

SHAFT

CV-22 STAIR ETR/SC-1 RB-2 P-1 ETR ETR NOTE 2

GENERAL FINISH NOTES

ROOM FINISH SCHEDULE ELEVATORS

ROOM NO

ROOM

NAME FLOOR FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES & REMARKS (SEE NOTES)

DB-20 ELEVATOR CPT-1 RB-1 MFG STD. MFG STD. MFG STD. NOTE 8

SS-1 SOLID SURFACE WILSONART SOLID SURFACE D354SL DESIGNER WHITE

GR-1 FLOOR & WALL GROUT CUSTOM BUILDING PRODUCTS CEG-LITE 165 DELOREAN GRAY 100% SOLIDS COMMERCIAL EPOXY GROUT

TFAW

TRAFFIC FLUID APPLIED

WATERPROOFING

SIKA

MISCELLANEOUS

ACT-1 ACOUSTICAL CEILNG TILE ACOUSTICAL SURFACES, INC. SOUND SILENCER - WHITE 24" X 24" USE WITH 15/16" GRID

CEILING

P-2 TRIM PAINT SHERWIN WILLIAMS PROMAR 200 SW7074 SOFTWARE

P-1 WALL PAINT SHERWIN WILLIAMS PROMAR 200 SW6245 QUICK SILVER

CT-1 CERAMIC TILE DALTILE SEMI-GLOSS SERIES 0190 ARCTIC WHITE 4-1/4" X 4-1/4"

WALLS

RB-2 RUBBER BASE JOHNSONITE TIGHTLOCK WALL BASE 71 STORM CLOUD 6-1/2" H

RB-1 RUBBER BASE JOHNSONITE TIGHTLOCK WALL BASE 71 STORM CLOUD 4-1/2" H

CTB-1 CERAMIC TILE BASE DALTILE SEMI-GLOSS SERIES A3401/O190 ARCTIC WHITE 4-1/4" X 4-1/4"

BASE

SC-1 SEALED CONCRETE

CPT-1 CARPET SHAW CONTRACT DIFFUSE 59575-75567 TRAIN STATION 24" X 24"

PT-1 PORCELAIN FLOOR TILE DALTILE VOLUME 1.0 VL73 STEREO GREY 12" X 12"

ESD-1

ELECTROSTATIC

DISSIPATIVE FLOORING...

ARMSTRONG EXCELON STATIC DISSIPATIVE FLOORING 51958 FOSSIL GRAY 12" X 12"

FOUR-PART SYSTEM TO INCLUDE STATIC DISSIPATIVE ADHESIVE, STATIC

DISSIPATIVE FLOOR TILE, STATIC DISSIPATIVE FLOOR POLISH, AND COPPER...

FLOORING

SYMBOL MATERIAL MANUFACTURER PRODUCT NAME NUMBER COLOR SIZE REMARKS

FINISH MATERIALS LEGEND

BID ALTERNATE PROJECT SCOPE

01/25/2023

Steven J. Birkley License # 11250 Exp 12/31/2023

A m e n d m e n t

/2

/2

ARIMS: 200A Disposition: Maintain for 15 yrs after construction

W

2Q R

R

_P la ns -0

Sheets
A-103 - NEW WORK PARTIAL PLAN - LEVEL 2
A-107 - NEW WORK FLOOR PLAN - LEVEL 8
A-108 - NEW WORK FLOOR PLAN - LEVEL 9
A-109 - NEW WORK FLOOR PLAN - LEVEL 10
A-110 - NEW WORK FLOOR PLAN - LEVEL 11
A-111 - NEW WORK FLOOR PLAN - LEVEL 12
A-112 - NEW WORK FLOOR PLAN - ROOF LEVEL
A-203 - ENLARGED EAST ELEVATION
A-501 - WALL SECTION AND DETAILS
A-502 - BALCONY DETAILS
A-621 - FINISH SCHEDULE, FINISH LEGEND AND NOTES