W912QR21R0024_Plans-0002.pdf
PDF 8 MB Posted
- Attached to
- Construction of Target Structure at Ft. Knox
- Solicitation number
- W912QR21R0024
About this file
This federal contract opportunity notice seeks proposals for the construction of a training target structure at Fort Knox, Kentucky. The U.S. Army Corps of Engineers will issue a request for proposal for a firm-fixed-price construction contract with an estimated value between $10-25 million. Offerors must be registered in the System for Award Management database. Proposals will be evaluated using a best value tradeoff process considering past performance, technical capability, small business participation, and price. The contract duration is 720 calendar days from notice to proceed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912QR21R0024Specs-0004.pdf | ||
| W912QR21R0024Plans-0004.pdf | ||
| W912QR21R0024_Specs-0003.pdf | ||
| W912QR21R0024_Plans-0003.pdf | ||
| W912QR21R0024_Specs-0002.pdf | ||
| W912QR21R0024_Photos-0002.pdf | ||
| W912QR21R0024-0001.pdf | ||
| W912QR21R0024Specs-0000.pdf | ||
| W912QR21R0024Plans-0000.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R
IP
R A P
R
IP
R A P
R
IP
R A P
GRAVEL ROAD
G R
A V
E L R
O A
D
5 1/2
20'
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
SHEET ID
IS
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F T
K N
O X T
R A
IN
IN
G T
A R
G E
T S
T R
U C
T U
R E
F T
K N
O X
K E
N T
U C
K Y
P N
F
Y P
J
W A
L T
E R
S
B S
A Y
L O
R L
O U
IS
V
IL
L E
K E
N T
U C
K Y
CERTIFIED FINAL
R
H A
R R
IS
J A
N U
A R
Y
W
Q R
R
GENERAL SHEET NOTES
LEGEND
CONTRACTOR WORK LIMITS
SHEET KEYNOTES
2' FLAT-BOTTOM DITCH
PROFILES ON CG201.
5. PIPE SIZE AND INVERT ELEVATIONS PROVIDED IN PIPE
4. SEE SHEET CG201 FOR VERTICAL ALIGNMENT PROFILES.
PAVEMENT SWALE.
3. SPOT ELEVATION INDICATED AT PAVEMENT EDGE OR
IS 1 FT.
2. PROPOSED AND EXISTING CONTOUR INTERVAL
TO BE SEEDED PER SPECIFICATIONS.
1. UNLESS OTHERWISE NOTED, ALL DISTURBED AREAS
NEW GRAVEL
4. V-DITCH (SEE SHEET CG501 DETAIL F1)
FOR DETAIL)
3. SLOPED & FLARED HEADWALLS. (SEE SHEET CG501
CG501 FOR DETAIL.
DEEP TRENCH. BACKFILL WITH #57 STONE SEE SHEET
2. PLACE 6" DIA. POLYETHYLENE PERFORATED PIPE IN 4'
SHEET CS501)
1. HEADWALL FOR PERFORATED PIPE. (SEE DETAIL A6;
PIPE
12" REINFORCED CONCRETE
N 168 235.43
E 1 173 385.66
N 168 154.16
E 1 173 464.32
N 168 104.80
E 1 173 332.01
N 168 116.80
E 1 173 332.21
COURTYARD ACCESS ROAD
RELOCATED ACCESS ROAD
N 168 069.99
R 15 R
R
R
R
TO TIE INTO EXISTING ROAD
TRANSITION PAVEMENT SECTION CROSS SLOPE
TO TIE INTO EXISTING ROAD
TRANSITION PAVEMENT SECTION CROSS SLOPE
FFE = 459.5'
STORM 1
.5
5.
.5
.5
.3
.6
.9
.3
.4
.4
.4
.1
.3
.9
.0
.1
.2
.4
.7
.7
.7
0 450
.3
.4
.0
.0
.0
.0
.0
.5
LRL_Screen.dscriptLRL_pdf.pltcfg10:51:55 AM 3/17/2021
...\Military\477836\CAD_BIM\CAD_BIM\03_Sheets\477836_CG101_AMDT0002xxx.dgn
CG101A1
N
1"=30' 30' 60'0
GRADING PLAN
G R
A D
IN
G P
L A
N J S
C H
E N
K E
N F
E L
D E
R
M
A R
A M
E N
D M
E N
T
W
2Q R
R
Pl an s-
R
IP
R A P
R
IP
R A P
R
IP
R A P
GRAVEL ROAD
G R
A V
E L R
O
20'
20'
1 S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F T
K N
O X T
R A
IN
IN
G T
A R
G E
T S
T R
U C
T U
R E
F T
K N
O X
K E
N T
U C
K Y
P N
F
Y P
J
W A
L T
E R
S
B S
A Y
L O
R L
O U
IS
V
IL
L E
K E
N T
U C
K Y
CERTIFIED FINAL
R
H A
R R
IS
J A
N U
A R
Y
W
Q R
R
GENERAL SHEET NOTES
LEGEND
CONTRACTOR WORK LIMITS
SHEET KEYNOTES
2' FLAT-BOTTOM DITCH
PROFILES ON CG201.
5. PIPE SIZE AND INVERT ELEVATIONS PROVIDED IN PIPE
4. SEE SHEET CG201 FOR VERTICAL ALIGNMENT PROFILES.
PAVEMENT SWALE.
3. SPOT ELEVATION INDICATED AT PAVEMENT EDGE OR
IS 1 FT.
2. PROPOSED AND EXISTING CONTOUR INTERVAL
TO BE SEEDED PER SPECIFICATIONS.
1. UNLESS OTHERWISE NOTED, ALL DISTURBED AREAS
NEW GRAVEL
4. V-DITCH (SEE SHEET CG501 DETAIL F1)
FOR DETAIL)
3. SLOPED & FLARED HEADWALLS. (SEE SHEET CG501
CG501 FOR DETAIL.
DEEP TRENCH. BACKFILL WITH #57 STONE SEE SHEET
2. PLACE 6" DIA. POLYETHYLENE PERFORATED PIPE IN 4'
SHEET CS501)
1. HEADWALL FOR PERFORATED PIPE. (SEE DETAIL A6;
PIPE
12" REINFORCED CONCRETE
N 168 235.43
E 1 173 385.66
N 168 154.16
E 1 173 464.32
N 168 104.80
E 1 173 332.01
N 168 116.80
E 1 173 332.21
COURTYARD ACCESS ROAD
RELOCATED ACCESS ROAD
N 168 069.99
BID OPTION 003
CONTINUOUS FOOTER
BID OPTION 002
CONTINUOUS FOOTER
BID OPTION 004
FULL LENGTH UTILITY TUNNEL
R 15 R
10R
R
R
4 1
FFE = 459.5'
TO TIE INTO EXISTING ROAD
TRANSITION PAVEMENT SECTION CROSS SLOPE
TO TIE INTO EXISTING ROAD
TRANSITION PAVEMENT SECTION CROSS SLOPE
STORM 1
.5
5.
.5
.5
.3
.6
4 4
.9
.3
.4
.4
.4
.1
.3
.9
.0
.1
.2
.4
.7
.7
.7
0 450
.3
.4
.0
.0
.0
.0
.0
.5
LRL_Screen.dscriptLRL_pdf.pltcfg10:52:00 AM 3/17/2021
...\Military\477836\CAD_BIM\CAD_BIM\03_Sheets\477836_CG101A_AMDT0002xx.dgn
CG101AA1
1"=30' 30' 60'0
J S
C H
E N
K E
N F
E L
D E
R
BID OPTION 004 GRADING PLAN
B
ID
O
P T
IO
N
G
R A
D
IN
G P
L A
N
M A
R
A M
E N
D M
E N
T
W
2Q R
R
Pl an s-
20'
GENERAL SHEET NOTES
LEGEND
NEW WATER LINE
CONTRACTOR WORK LIMITS
NEW GATE VALVE
NEW YARD HYDRANT
SHEET KEYNOTES
GENERAL NOTES, LEGEND, AND DIVISION OF RESPONSIBILITY.
10.SEE SHEET EU001 FOR EXTERIOR ELECTRICAL SYSTEM
DISTRICT NO. 1.
INSPECTIONS, ETC. REQUIRED BY HARDIN COUNTY WATER
9. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, FEES,
DRAWINGS.
MAXIMUM DEPTH OF 60", UNLESS OTHERWISE NOTED ON THE
8. WATER LINES SHALL HAVE A MINIMUM COVER OF 36" AND A
QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.
MANUFACTURER MEET OR EXCEED THE STANDARD OF
AND CHARACTERISTICS OF THE SUBSTITUTED
BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY
MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE
SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED
UNLESS INDICATED OTHERWISE ON THE PLANS OR
NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS.
MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND
7. CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH
AUTOMATIC FLUSHER TO THE END OF THE NEW LINE.
COUNTY WATER DISTRICT TO RELOCATE THE CURRENT
THE CONTRACTOR SHALL COORDINATE WITH HARDIN 6.
WATER UTILITY DISTRIBUTION PIPING.
ACCORDANCE WITH SPECIFICATIONS SECTION 33.11.00
5. INSTALLATION OF NEW WATERLINE SHALL BE IN
WITNESSED BY THE GOVERNMENT.
NO. 1 DETAILS ON SHEET CU501. TESTING SHALL BE
UTILITIES-2012.PDF AND HARDIN COUNTY WATER DISTRICT
COM/WP- CONTENT/UPLOADS/GENERAL-SPECIFICATIONS-ALL
WATER DISTRICT NO. 1 SPECIFICATIONS AT HTTPS:/'/HCWD.
(270) 776-9477. INSTALLATION SHALL BE PER HARDIN COUNTY
HARDIN COUNTY WATER DISTRICT NO. 1, MR. BRETT PYLES
LINE CONNECTION TO THE EXISTING WATERLINE WITH
4. THE CONTRACTOR SHALL COORDINATE THE NEW WATER
ON SITE.
3. NOLIN RECC IS THE OWNER OF THE ELECTRIC UTILITIES
CONTRACTING OFFICER 14 DAYS PRIOR TO THE OUTAGE.
2. ANY UTILITY OUTAGES SHALL BE COORDINATED WITH THE
CONFLICTS OR DISCREPENCIES PRIOR TO INSTALLATION.
THE CONTRACTING OFFICER SHOULD BE NOTIFIED OF ANY
UTILITIES AND FIELD VERIFYING ALL EXISTING UTILITIES.
1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL
H C
C H
N 168 235.43
E 1 173 385.66
N 168 154.16
E 1 173 464.32
N 168 104.80
E 1 173 332.01
N 168 116.80
E 1 173 332.21
COURTYARD ACCESS ROAD
RELOCATED ACCESS ROAD
N 168 069.99
R 15 R
R
R
R
A1
CU501
CU501
A4
CU501
C7
CU501
C4
CU501
A7
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L
L O
U
IO
S V
IL
L E
K E
N T
U C
K Y
A N
S I
D
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F T
K N
O X T
R A
IN
IN
G T
A R
G E
T S
T R
U C
T U
R E
F T
K N
O X
K E
N T
U C
K Y
P N
F
Y P
CERTIFIED FINAL
J A
N U
A R
Y
W
Q R
R
M A
R
A M
E N
D M
E N
T
LRL_Screen.dscriptLRL_pdf.pltcfg3:46:04 PM 3/16/2021
...\Soo Locks\471310\CAD_BIM\CAD_BIM\03_Sheets\477836_CU102xxx.dgn
CU102A1
M A
T C
H L
IN
E S
E E S
H E
E T C
U
1"=30' 30' 60'0
UTILITY PLAN
J S
C H
E N
K E
N F
E L
D E
R
S
A L W
A R I/
C
K R
IS
H
T
H
IB
B S /C
K R
IS
H
K
B U
R N
S
U T
IL
IT
Y P
L
10. ELECTRICAL EQUIPMENT PAD. SEE SHEET EU501 FOR LAYOUT.
SEE SHEET EU503 DEATIL A1 FOR ELEVATION.
#1, #2,& #3. SEE SHEET EU503 FOR POLE DETAIL.
9. COMMUNICATIONS AND POWER TO VSS EXTERIOR TOWERS
SHOWN. SEE SHEET EU501 FOR DETAIL.
8. COMMUNICATIONS PULLBOX TO BE EVERY 600' OR AS
FOR DIAGRAM.
SEE SHEET TY601 FOR ONE-LINE. SEE SHEET EU503
EXISTING AT RANGE 4 CONTROL OFFFICE.
7. 24 SM FOR COMMUNICATIONS CONNECTION TO
FOR DETAIL. SEE SHEET E-601 FOR ONE-LINE DIAGRAM.
AND THE EXISTING DUCKBANK AT RANGE 4. SEE SHEET EU501
6. ELECTRICAL DUCTBANK BETWEEN THE RANGE 5 TRANSFORMER
SEE SHEET EU501 FOR DETAIL.
SEE SHEET EU101 FOR DIVISION OF RESPONSIBLITY.
RECC AND INSTALLED EVERY 400' OR AS DESIGNATED.
5. 48X48 ELECTRICAL VAULT TO BE SUPPLIED BY NOLIN
4. TERMINATE NEW 4" HDPE WATER MAIN
THE END OF THE NEW 4" WATER MAIN.
3. THE EXISTING AUTOMATIC FLUSHER NEW LOCATION AT
2. 1" HDPE WATER SERVICE LINE.
1. 4" HDPE WATER MAIN.
W
2Q R
R
Pl an s-
GRAVEL AREA
Gravel Area
443.90 444.11
445.26
445.39
INV = 445.57
445.70
446.94
447.13
INV = 447.63
INV = 448.08
448.43
NUMBER: 54205
Direction of pipe
449.68
449.70
449.70
449.82
449.91
GRAVEL ROAD
450.10
NUMBER: 54206
451.36 451.74
SIZE: 8
TYPE: CHAIN LINK
SIZE: 8'
TYPE: CHAIN LINK
SIZE: ?
TYPE: CHAIN LINK
453.94
SIZE: 8
TYPE: CHAIN LINK
454.23
454.40
454.78
455.10 455.58
455.64 gravel
H
N 168716.52
E 1178039.50
ELEV 455.72
455.89
SIZE: 8'
TYPE: CHAIN LINK
456.28
456.44
456.50
F
N 168791.66
E 1178030.62
ELEV 456.85
SIZE: 8'
TYPE: CHAIN LINK
457.51
457.54
N 168782.08
E 1177926.22
ELEV 457.76
457.92
TYPE: OFFICE
TYPE: OFFICE
AC
E
GENERAL SHEET NOTES
LEGEND
NEW WATER LINE
CONTRACTOR WORK LIMITS
NEW GATE VALVE
NEW YARD HYDRANT
SHEET KEYNOTES
GENERAL NOTES, LEGEND, AND DIVISION OF RESPONSIBILITY.
10.SEE SHEET EU001 FOR EXTERIOR ELECTRICAL SYSTEM
DISTRICT NO. 1.
INSPECTIONS, ETC. REQUIRED BY HARDIN COUNTY WATER
9. CONTRACTOR IS RESPONSIBLE FOR ALL PERMITS, FEES,
DRAWINGS.
MAXIMUM DEPTH OF 60", UNLESS OTHERWISE NOTED ON THE
8. WATER LINES SHALL HAVE A MINIMUM COVER OF 36" AND A
QUALITY AND CHARACTERISTICS OF THE BASIS OF DESIGN.
MANUFACTURER MEET OR EXCEED THE STANDARD OF
AND CHARACTERISTICS OF THE SUBSTITUTED
BE SUBSTITUTED AS LONG AS THE STANDARD OF QUALITY
BASIS OF DESIGN PRODUCTS, OTHER MANUFACTURERS MAY
MANUFACTURERS ARE THE BASIS OF DESIGN. FOR THESE
SPECIFICATIONS (E.G. SOLE-SOURCE), ALL LISTED
UNLESS INDICATED OTHERWISE ON THE PLANS OR
NOT IN CONFLICT WITH OTHER CONTRACT PROVISIONS.
MEETS THE GOVERNMENT'S MINIMUM REQUIREMENTS AND
7. CONTRACTORS ARE FREE TO USE ANY PRODUCT WHICH
AUTOMATIC FLUSHER TO THE END OF THE NEW LINE.
COUNTY WATER DISTRICT TO RELOCATE THE CURRENT
THE CONTRACTOR SHALL COORDINATE WITH HARDIN 6.
WATER UTILITY DISTRIBUTION PIPING.
ACCORDANCE WITH SPECIFICATIONS SECTION 33.11.00
5. INSTALLATION OF NEW WATERLINE SHALL BE IN
WITNESSED BY THE GOVERNMENT.
NO. 1 DETAILS ON SHEET CU501. TESTING SHALL BE
UTILITIES-2012.PDF AND HARDIN COUNTY WATER DISTRICT
COM/WP- CONTENT/UPLOADS/GENERAL-SPECIFICATIONS-ALL
WATER DISTRICT NO. 1 SPECIFICATIONS AT HTTPS:/'/HCWD.
(270) 776-9477. INSTALLATION SHALL BE PER HARDIN COUNTY
HARDIN COUNTY WATER DISTRICT NO. 1, MR. BRETT PYLES
LINE CONNECTION TO THE EXISTING WATERLINE WITH
4. THE CONTRACTOR SHALL COORDINATE THE NEW WATER
ON SITE.
3. NOLIN RECC IS THE OWNER OF THE ELECTRIC UTILITIES
CONTRACTING OFFICER 14 DAYS PRIOR TO THE OUTAGE.
2. ANY UTILITY OUTAGES SHALL BE COORDINATED WITH THE
CONFLICTS OR DISCREPENCIES PRIOR TO INSTALLATION.
THE CONTRACTING OFFICER SHOULD BE NOTIFIED OF ANY
UTILITIES AND FIELD VERIFYING ALL EXISTING UTILITIES.
1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL
H C
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L
L O
U
IO
S V
IL
L E
K E
N T
U C
K Y
A N
S I
D
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F T
K N
O X T
R A
IN
IN
G T
A R
G E
T S
T R
U C
T U
R E
F T
K N
O X
K E
N T
U C
K Y
P N
F
Y P
CERTIFIED FINAL
J A
N U
A R
Y
W
Q R
R
M A
R
A M
E N
D M
E N
T
LRL_Screen.dscriptLRL_pdf.pltcfg3:46:06 PM 3/16/2021
...\Soo Locks\471310\CAD_BIM\CAD_BIM\03_Sheets\477836_CU111xxx.dgn
CU111A1
1"=30' 30' 60'0
M A
T C
H L
IN
E S
E E S
H E
E T C
U
UTILITY PLAN
J S
C H
E N
K E
N F
E L
D E
R
S
A L R
A W I/
C
K R
IS
H
T
H
IB
B S /C
K R
IS
H
K
B U
R N
S
U T
IL
IT
Y P
L
TY601 FOR ONE-LINE. SEE SHEET EU503 FOR DIAGRAM.
CONTROL OFFICE. COORDINATE WITH COR. SEE SHEET
TO EXISTING FIBER OPTIC PATCH PANEL AT RANGE 4
3. COMMUNICATIONS CONNECTION TO ENTER AND CONNECT
SHOWN. SEE SHEET EU501 FOR DETAIL.
2. COMMUNICATIONS PULLBOX TO BE EVERY 600' OR AS
FOR DIAGRAM.
SEE SHEET TY601 FOR ONE-LINE. SEE SHEET EU503
EXISTING AT RANGE 4 CONTROL OFFFICE.
1. 24 SM FOR COMMUNICATIONS CONNECTION TO
W
2Q R
R
Pl an s-
E. SEISMIC:
RISK CATEGORY: II
Ie= 1.25 Ss= 0.209
SDS= 0.22
S1= 0.108 Sd1= 0.17 Cs= 0.056
SITE CLASS: D
BASIC SEISMIC FORCE RESISTING SYSTEM:
ORDINARY REINFORCED CONCRETE SHEAR WALLS, R=4
SEISMIC DESIGN CATEGORY= C
ANALYSIS PROCEDURE= EQUIVALENT LATERAL FORCE PROCEDURE
SEISMIC BASE SHEAR VALUE= 935 KIPS
F. SOILS:
SOIL DENSITY= 120 pcf
ANGLE OF INTERNAL FRICTION OF THE SOIL (Ф): 30 DEGREES
G. BLAST LOADS:
THE STRUCTURE HAS BEEN DESIGNED FOR THE CHARGE WEIGHTS AND LOCATIONS SHOWN ON
SHEETS S-003 THROUGH S-006.
2.0 GENERAL
2.1 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS PRIOR TO
CONSTRUCTION/FABRICATION, CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
2.2 THE STRUCTURE (MEMBERS AND CONNECTIONS) HAS BEEN DESIGNED TO SUPPORT IN-PLACE
DESIGN LOADS ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LIMITING CONSTRUCTION
LOADS SUCH THAT THESE LOADS DO NOT EXCEED THE DESIGN LOADS NOTED ABOVE.
2.3 IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE CONSTRUCTION METHODS,
PROCEDURES, AND SEQUENCES TO ENSURE STABILITY AND SAFETY DURING CONSTRUCTION.
THE CONTRACTOR SHALL TAKE NECESSARY PRECAUTIONS TO PROTECT AND MAINTAIN THE
STRUCTURAL INTEGRITY OF ALL NEW AND EXISTING CONSTRUCTION AT ALL STAGES.
2.4 SECTIONS AND DETAILS SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE CONSIDERED
TYPICAL FOR SIMILAR CONDITIONS THAT DO NOT HAVE A SPECIFIC SECTION INDICATED.
2.5 THE CONTRACTOR SHALL COORDINATE STANDARD DRAWINGS WITH THE VENDOR/MANF, SHOP
DRAWINGS TO VERIFY SIZES AND LOCATIONS OF OPENINGS, SLEEVES, INSERTS, DEPRESSIONS, FINISHES, SLOPES, ETC. ANY DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER.
2.6 SEE CIVIL SITE LAYOUT DRAWINGS (PART OF SITE ADAPTATION) FOR ACTUAL FINISHED FLOOR
ELEVATIONS (F.F.E.) FOR ALL BUILDINGS, ELEVATIONS SHOWN IN STRUCTURAL DOCUMENTS
WILL BE BASED ON REFERENCED F.F.E. EQUAL TO 0.0, U.N.O.
2.7 ANY DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, REFERENCE STANDARDS, OR
GOVERNING CODE, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. CONTRACTOR
SHALL NOTIFY THE CONTRACTING OFFICER AND OBTAIN DIRECTION PRIOR TO PROCEEDING.
2.8 CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND BRACING OF ALL STRUCTURAL
WORK, AND SOIL EXCAVATION AS REQUIRED, SHORING AND BRACING SHALL NOT BE REMOVED
UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS,
AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH.
2.9 BLAST DOOR MANUFACTURER SHALL DESIGN THE BLAST DOOR, DOOR FRAME, AND
ANCHORAGE OF DOOR FRAME TO THE CONCRETE. ANCHORAGE SHALL MEET ACI
REQUIREMENTS.
3.0 FOUNDATIONS
3.1 DESIGN ASSUMPTION FOR MAXIMUM ALLOWABLE BEARING PRESSURE OF 3000 (PSF) WITH THE EXCEPTION
OF THE 2500 PSF FOR THE CONTINUOUS FOOTING OF THE PERIMETER WALL.
3.2 ASSUMED UNIT WEIGHT OF SOIL FOR DESIGN: 120 PCF.
3.3 CONCRETE SHALL NOT BE PLACED OVER FROZEN SOIL OR FOOTING EXCAVATIONS SUBJECTED TO WATER.
3.4 FOUNDATION DESIGN IS BASED ON THE RECOMMENDATIONS CONTAINED IN THE 31 00 00 EARTHWORK
SPEC.
3.5 ALL FOUNDATION BEARING SURFACES SHALL BE INSPECTED AND APPROVED BY THE CONTRACTOR'S
GEOTECHNICAL ENGINEER PRIOR TO PLACING CONCRETE.
4.0 CONCRETE
4.1 ALL CONCRETE WORK INCLUDING DETAILING, FABRICATION, PLACEMENT OF REINFORCING, MIXING, HANDLING, PLACING, FINISHING, AND CURING SHALL CONFORM TO THE FOLLOWING DOCUMENTS.
ACI 305............................"STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE"
ACI 315............................"MANUAL OF STANDARD PRACTICE FOR DETAILING
REINFORCED CONCRETE STRUCTURES"
ACI 318............................"BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
4.2 ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 6000 PSI AT 28 DAYS, U.N.O.
4.3 REINFORCING BARS SHALL BE ASTM A615 GRADE 60 REINFORCEMENT.
4.4 FABRICATE AND PROVIDE BAR SUPPORTING ACCESSORIES IN ACCORDANCE WITH ACI MANUAL OF STANDARD PRACTICE AND C.R.S.I. SPECIFICATIONS. REINFORCING SHALL NOT BE WELDED IN
ANY MANNER U.N.O. IN CONSTRUCTION DOCUMENTS.
4.5 REINFORCING BARS SHALL BE CONTINUOUS WITH CLASS "B" TENSION LAP SPLICES COMPLYING
WITH ACI 318-14, U.N.O.
4.6 CONCRETE COVERAGE OF REINFORCEMENT FOR CAST-IN-PLACE CONSTRUCTION U.N.O.:
CONCRETE CAST AGAINST EARTH:....................3 INCHES
FORMED CONCRETE EXPOSED TO EARTH OR WEATHER:
NO. 6 BAR AND LARGER...........................2 INCHES
NO. 5 BAR AND SMALLER..........................2 INCHES
4.7 PROVIDE REINFORCING BARS IN CONCRETE FOOTINGS TO MATCH THE SIZE AND SPACING OF THE HORIZONTAL REINFORCING AT ALL CORNERS AND INTERSECTIONS OF STRIP FOOTINGS. PROVIDE
LEG LENGTH EQUIVALENT TO CLASS "A" TENSION LAP SPLICE U.N.O.
4.8 PROVIDE DOWEL TO FOUNDATION WITH 90 DEGREE HOOK TO MATCH THE SIZE AND SPACING OF
VERTICAL REINFORCING AT ALL WALLS AND PILASTERS.
4.9 FOOTINGS AND SLABS SHALL HAVE NO HORIZONTAL JOINTS, BUT DISCONTINUOUS THROUGH ALL
CONTROL JOINTS, U.N.O.
4.10 REINFORCEMENT SHALL NOT BE BENT OR STRAIGHTENED IN A MANNER THAT WILL DAMAGE THE
MATERIAL. BARS WITH KINKS OR IMPROPER BENDS SHALL NOT BE USED.
4.11 REINFORCEMENT SHALL BE CONTINUOUS THROUGH ALL CONSTRUCTION JOINTS, BUT
DISCONTINUOUS THROUGH ALL CONTROL JOINTS, U.N.O.
4.12 ALL FORMED CONCRETE SURFACES THAT ARE EXPOSED TO VIEW SHALL HAVE SURFACE
IRREGULARITIES LESS THAN 1/8" WITHIN A FIVE FEET LENGTH WHEN MEASURED WITH A STRAIGHT
EDGE. CONCRETE BELOW GRADE OR NOT EXPOSED TO VIEW SHALL HAVE SURFACE
IRREGULARITIES LESS THAN 1" WITHIN A FIVE FEET LENGTH WHEN MEASURED WITH A STRAIGHT
EDGE.
4.13 REFER TO GEOTECHNICAL REPORT FOR RECOMMENDATIONS RELATIVE TO SUBGRADE
PREPARATION FOR SLAB-ON-GRADE WORK.
4.14 REINFORCEMENT SPLICES ON OPPOSITE FACES AND ON ADJACENT BARS SHALL BE STAGGERED
PER UFC 3-340-02 REQUIREMENTS.
4.15 SELF-CONSOLIDATING CONCRETE (SCC) IS RECOMMENDED IN HEAVILY REINFORCED COMPONENTS.
SUCH AS; THE WALLS, FLOOR, AND ROOF SLABS. THE CONTRACTOR SHALL CONFIRM THAT THE
FORM WORK AND SCAFFOLDING HAVE BEEN DESIGNED TO RESIST THE FLUID WEIGHT OF THE SCC.
4.16 RECOMMENDED NOMINAL SIZE OF MAX AGGREGATE IS 0.375 IN.
4.17 ALL SINGLE LEG STIRRUPS SHALL HAVE 135 DEGREE BENDS ON EACH END.
5.0 STRUCTURAL STEEL
5.1 STRUCTURAL STEEL FABRICATION, ERECTION, AND CONNECTION DESIGN SHALL CONFORM TO
A.I.S.C.'S "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
5.2 STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING DESIGNATIONS FOR THE BLAST DOORS
CONSTRUCTION:
STEEL CHANNELS, ANGLES, PLATES, AND BARS...................ASTM A36/ASTM A572(FRAMES)
RECTANGULAR, SQUARE, AND ROUND HSS...........................ASTM A500, GRADE B
5.3 STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING DESIGNATIONS FOR ALL OTHER
CONSTRUCTION:
W SHAPES..............................................................................ASTM A992 STEEL CHANNELS, ANGLES, PLATES, AND BARS............ASTM A36 AND ASTM A572 (GR. 50)
RECTANGULAR, SQUARE, AND ROUND HSS....................ASTM A500, GRADE B
5.4 STRUCTURAL FASTENERS SHALL CONFORM TO THE FOLLOWING DESIGNATION:
ANCHOR BOLTS...................................ASTM F1554 (55 KSI)
THREADED RODS................................ASTM A36
HEADED STUDS.................................ASTM A108, GRADES 1015 TO 1020 (65 KSI TENSILE STRENGTH) DEFORMED BAR ANCHORS.............ASTM A496, TYPE C (80 KSI MIN. TENSILE STRENGTH)
5.5 BOLTED CONNECTIONS SHALL CONFORM TO RCSC'S " SPECIFICATION FOR STRUCTURAL JOINTS
USING ASTM A325 OR A490 BOLTS". ALL BOLTS SHALL BE 3/4" DIAMETER U.N.O.
5.6 WELDED CONNECTIONS SHALL CONFORM TO AWS D1.1 "STRUCTURAL WELDING CODE-STEEL".
MINIMUM SIZE FILLET WELDS SHALL BE 1/4 INCH U.N.O. AND ELECTRODES SHALL BE E70xx. WELDERS
SHALL BE QUALIFIED IN ACCORDANCE WITH AWS.
5.7 ALL EXTERIOR STEEL EXPOSED TO THE WEATHER, TO INCLUDE ALL STEEL INSIDE OF THE EXTERIOR WALLS OF THE STRUCTURE, SHALL BE HOT DIPPED GALVANIZED, U.N.O. MEMBERS NOT REQUIRED
FOR CORROSION PROTECTION SHALL RECEIVE ONE COAT OF STANDARD PRIMER PAINT. DO NOT
PRIME OR PAINT SURFACES WHICH ARE TO RECEIVE FIELD WELDED HEADED SHEAR STUDS.
PROVIDE 3 INCHES MINIMUM COVER FOR ALL STEEL BELOW GRADE AND PAINT WITH TWO COATS OF
COAL TAR EPOXY. EPOXY COATING SHALL BE IN ACCORDANCE WITH PAINT SPECIFICATION
SSPC-PAINT 16.
5.8 ALL STIFFENERS AND GUSSETS PLATES SHALL BE MINIMUM 1/2" THICK, U.N.O.
5.9 ANY PENETRATIONS OF STEEL PLATES USED FOR ERECTION MUST BE APPROVED BY SEOR PRIOR
TO PLACEMENT.
US Army Corps of Engineers ®
SHEET 5701 OF
SHEET ID
S-001
G
EN
ER
AL
N O
TE
S
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
M C
P
M C
P
JJ
S
R
SW
W
2Q R
R
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
1.0 DESIGN CRITERIA:
A. BUILDING CODES AND SPECIFICATIONS:
1. INTERNATIONAL BUILDING CODE 2015 (IBC) AS MODIFIED BY UFC 1-200-01
2. AMERICAN CONCRETE INSTITUTE (ACI 318-14)
3. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC 14th ED.)
4. AMERICAN WELDING SOCIETY, A.W.S.
B. LIVE LOADS:
ROOF...............................................100 PSF
FLOOR.............................................100 PSF
C. SNOW LOAD:
GROUND SNOW LOAD (Pg)= 15 PSF FLAT ROOF SNOW LOAD (Pf)= 11.34 PSF
IMPORTANCE FACTOR (I)= 1.0
EXPOSURE CATEGORY (Ce)=1.0 THERMAL CATEGORY (Ct)=1.2 SLOPE FACTOR (Cs) = 1.0
D. WIND LOAD:
BASIC WIND SPEED = 105 MPH
IMPORTANCE FACTOR (I) = 1.0
EXPOSURE CATEGORY: C
ENCLOSURE CLASSIFICATION: ENCLOSED
GCPi: +0.18/-0.18
CERTIFIED FINAL
SNOW DRIFT LOADING
42.28 psf
42.28 psf42.28 psf
42.28 psf
4'-35 8"
(TYP)
1' -6
3 4"
915 16
1'-27 8"1'-27
8"
2'-2 3 16"
1' -0
1' -7
1 16
16"
1'-27 8"
16"
53 8"
1'-27 8"
915 16
1' -7
1 16
16"
53 8"
30 psf 24.9 psf
27.93 psf
30.16 psf
30.16 psf26.34 psf
29.84 psf
29.04 psf
29.84 psf 27.93 psf 24.9 psf
27.93 psf
29.04 psf
33.35 psf
COMPONENTS & CLADDING
3 32
2 2
3 3 a a a a
2a 2a
NOTE: PARAPET GREATER
THAN 3 FT HEIGHT,
PER ASCE 7 ZONE 3 IS
TAKEN AS ZONE 2.
C&C p(PSF)
500 SQ. FT.20 SQ. FT.10 SQ. FT.ZONE
-28.58 PSF-39.16 PSF-41.81 PSF1
-47.10 PSF-62.45 PSF-65.62 PSF2
11.34 psf
11.34 psf
Am en dm en t 0
W
2Q R
R
Pl an s-
FOUNDATION PLAN VIEW
SCALE: 1/8" = 1'-0"
80'-0"
80'-0"
'-0
5'-0"
(TYP.)
32" MAT
FOUNDATION
6' -0
6'
-0
US Army Corps of Engineers ®
SHEET 5707 OF
SHEET ID
S-100
FO
U
N D
AT
IO
N P
LA
N
V
IE
W
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
M C
P
M C
P
JJ
S
R
SW
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
14'-0" 16'-0" 22'-6" 16'-0" 11'-6"
D
A S100 S310
'-1
1" 6'
-0
'-8
6'
-0
'-2
5'-0"
'-6
'-8
'-1
0"
'-0
2'-6"
(TYP.)
4'-0"
(TYP.)
PLAN NORTH
C
B
A
2'
-0
'-0
'-6
'-6
2 3 4 5 6
15'-0"
192'-6"
182'-0"
50'-0"
(TYP)
CONTINUOUS
FOOTING PLACED
FOR FUTURE
WALL WITH TOP
OF FOOTING
AT GRADE
(OPTION 002)
2'-8" THICK
CONTINUOUS
FOOTING
WALL 10'-0"
ABOVE GRADE
B S100 S308
C S100 S308
'-0
8'-0"2'-0"6'-0"50'-0"6'-0"8'-0" 2'-0"
8' -0
C S100 S310
32" MAT FOUNDATION
S101
S101
S101
90'-0"
'-0
2' -7
5'
-8
5'-8" 2'-7"
'-0
1/2" EXP JT.
32" MAT FOUNDATION
'-5
1 2" 15'-31
2"
10'-8"3'-0"
'-8
1 4" 2'
-0
15'-41 2"
5' -0
A S100 S311
'-0
4'-6" 1'-0"
4'-6"
1/2" EXP JT.
32" MAT
FOUNDATION
4' -3
3 8"
13'-11 4"
S101
S100 S312
2' -0
4'
-0
2' -0
2'-0"
1/2" EXP JT.1/2" EXP JT.
12'-0"
1'-0"
(TYP)
5'-3"
(TYP)
5'-3"
(TYP)
11'-6"
(TYP)
'-0
(T
YP
49'-0"
S100 S314
2'-2" 5'-0"
5' -6
32" MAT
FOUNDATION
1/2" EXP JT
SEE CIVIL
DRAWINGS
FOR HEADWALL
LOCATION AND
TUNNEL
LENGTH
LEGEND
STEEL LINER
PLATES ON
WALLS
WEEP HOLES
2'-0" (3'-0" ONLY AT
DOUBLE PANEL
LOCATION)
WIDE VERTICAL
EMBED PLATES
1/2" STEEL EMBED
PLATE ON MAT
(SEE S-511 FOR
TYPICAL SECTION)
1/2" EXP JT
1/2" EXP JT.
CONTINUOUS
FOOTING PLACED
FOR FUTURE
WALL WITH TOP
OF FOOTING
AT GRADE
(OPTION 003)
1/16"
PER FT.
SLOPE
1/16"
PER FT.
SLOPE
20'-0"
'-0
S311 B
S100
NOTE: SEE ARCHITECTURAL DRAWINGS FOR FLOOR
SLOPE AROUND EXTERIOR PANELS.
CERTIFIED FINAL
SEE S-705
FOR STEEL
PLATE
STRIPS
SEE S-707
FOR STEEL
PLATE STRIPS
(AT CORNER)
W
2Q R
R
Am en dm en t 0
W
2Q R
R
Pl an s-
UP
DN
DN
FIRST FLOOR PLAN VIEW
SCALE: 1/8" = 1'-0"
A S500
80'-0"
'-0
12'-6" 10'-0" 9'-5"
10"
9'-9" 26'-10"
'-0
'-1 0"
'-4
'-8
'-8
29'-2" 12'-8" 9'-2" 16'-11"
80'-0"
'-0
'-5
'-1 0"
'-1
0"
'-0
A S101 S200
4'-0"
4' -4
" 20'-0"
'-0
'-0
'-0
9'-0"
8'-0"
9' -0
" 9'-6"
COM
ROOM
IN-PLAY
COM
ROOM
RR RR KITCHENETTE/CAFETERIA
C O
N
SU
LA
R
S
EC
TI
O
N
ATRIUM
(OPEN TO ABOVE)
AD
M
IN
S
EC
TI
O N
LOBBY
12'x12'
BREACHABLE
PANEL
(OPTION 006)
12'x12'
BREACHABLE
PANEL
(OPTION 006)
12'x12'
BREACHABLE
PANEL
AT CORNER
(OPTION 006)
(SEE S-707)
12'x12'
BREACH-
ABLE
PANEL
12'x12'
BREACHABLE
PANEL
(OPTION 006)
A S101 S202
A S101
A S101 S203
B S101 S500
A
P1 IN WALL PILASTER
AT EDGES (SEE S-500)
1/2" STEEL PLATE
ALL AROUND ROOM
(ABOVE AND BELOW WINDOWS)
1/2" STEEL PLATE
P3
P3
P3
P4
P3
P3
P3
P2
P2
P2
P4
P1P2 P1 P1 P1 P1
P2
P2
P2
P2
P2P2P2P2
P2
P2
P2
P2
P2
P2 P2
P2
P2
P2
P1 P1
P1
P1
P1
S201
3' -1
3'-1"
4' -0
6' -0
(T
YP
5'-0"
(TYP.)
2' -6
TY
P
EX
T.
W
AL
LS
2' -6
2'
-6
S102 S103
S102 S103
S102 S103
S102 S103
3'-6" 3'-0" 3'-0" 11'-103 4" 6'-0"
6'-0" 8'-21 2" 6'-0"
6'-0" 1'-43 4" 2'-6"
'-0
3'
-1 0"
9' -0
'-0
3' -1
0"
7"2'-6"
1' -2
'-0
'-8
'-0
'-2
3'
-6
S101 S303
S102
4'-0"
S101 S309
US Army Corps of Engineers ®
SHEET 5708 OF
SHEET ID
S-101
FI
R
ST
F
LO
O
R P
LA
N
V
IE
W
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
M C
P
M C
P
JJ
S
R
SW
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
14'-0" 16'-0" 22'-6" 16'-0" 11'-6"
1 2 3 4 5 6
'-0
'-6
'-6
A
B
C
D
S103
S101
S101 S500
PLAN NORTH
C S100 S308
S101
C S100 S310
S101
B S100 S308
S101
P2
P2
'-0
1'-0"
LEGEND
STEEL LINER
PLATES ON
WALLS
2'
-0
15'-0"
192'-6"
182'-0"
50'-0"
(TYP)
2'-8" THICK
CONTINUOUS
FOOTING
12 INCH
WALL
'-0
8'-0"2'-0"6'-0"
50'-0"
6'-0"8'-0" 2'-0"
8' -0
32" MAT FOUNDATION
1/2" EXP JT.1/2" EXP JT.
12'-0"
1'-0"
(TYP)
5'-3"
(TYP)
5'-3"
(TYP)
11'-6"
(TYP)
49'-0"
'-0
(T
YP
NOTE: SEE S-501 TO S-506 FOR PILASTER
SECTIONS AND DETAILS.
WEEP HOLES
INTERIOR PANELS
(OPTION 001)
2'-0" (3'-0" ONLY AT
DOUBLE PANEL
LOCATION)
WIDE VERTICAL
EMBED PLATES
4'-4"
3'-8"
D1 D1
D1
D1
D1
D1D1D1 D1
D1
D1
D1
D1
D2
D2
D1
D1
SEE S-705
FOR FIRST
FLOOR
PLATE
STRIPS
CAMERA
PROTECTION
BOXES (SEE S-512)
CAMERAS
(SEE TY-107)
'-0
20'-0"
S101 S507
S102
SEE S-506 FOR
GUARDHOUSE
OPENING FRAMES
P2
CERTIFIED FINAL
W
2Q R
R
Am en dm en t 0
W
2Q R
R
Pl an s-
PARAPET WALL TYPICAL SECTION
SCALE: 3/4" = 1'-0"
1'-6"
3' -6
2'
-2
#6 DIAGONAL DIMENSIONS
IN PARAPET WALL
SCALE: 3/4" = 1'-0"
1' -1
11 4"
1'-111 4"
3'-6 18 "
#6 DIAGONALS
#9's @ 6" C/C
GRADE 60 REINF.
E.F.
#4's @ 4" C/C
SINGLE LEG
STIRRUPS
#5's @ 8" C/C
GRADE 60 REINF.
E.F.
#6 @ 6" C/C DIAGONALS
SEE S-107 FOR
ROOF SLAB
REINFORCEMENT
SEE S-500 FOR WALL
REINFORCEMENT
US Army Corps of Engineers ®
SHEET 5746 OF
SHEET ID
S-511
TY
PI
C
AL
S
EC
TI
O
N S
AN
D
D
ET
AI
LS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
M C
P
M C
P
JJ
S
R
SW
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
LO
U
IS
VI
LL
E D
IS
TR
IC
T
INTERIOR PANEL EMBED
PLATE TYPICAL SECTION
SCALE: 3/4" = 1'-0"
1/2"Ø 0'-5" STEEL
ANCHOR STUDS
@ 1'-0" C/C SPACING
8" 8"4" 4"
2'-0"
1' -0
(T
YP
1. SEE PLAN VIEW FOR LOCATIONS OF STEEL EMBED PLATES
AROUND INTERIOR PANELS.
2. IN LOCATIONS WHERE PANEL IS CLOSE TO AN OPENING, AN
UNSYMMETRICAL PANEL PLACEMENT WAS USED.
3. SEE S-506 FOR TYPICAL CONFIGURATION.
1/2"Ø 0'-5" STEEL
ANCHOR STUDS
1/2" A36 STEEL
EMBED PLATE
L5x5x7/8
(TYP)
(OPTION 001)
TYPICAL STEEL LINER
PLATE SECTION
SCALE: 3/4" = 1'-0"
1/2"Ø 0'-5" STEEL
ANCHOR STUDS
1/2"Ø 0'-5" STEEL
ANCHOR STUDS
2'-0"
2' -0
1/4" OR 1/2"
A36 STEEL
LINER PLATE
CONCRETE
SURFACE
1/2"Ø x 0'-6"
STUD ANCHORS
@ 1'-0" C/C
1/2" x 7" CONT.
STEEL PLATE
1/2" x 1'-6" CONT.
STEEL PLATE
TYPICAL REAR STAIR ELEVATION
SCALE: 3/4" = 1'-0"
2' -8
6"
12'-0"
2'-0" 2'-2" 2'-0" 5'-6"
11"
TYP
7" TY
P
1' -1
0" -0
2'
-0
2'- 0"
TY
P
2'-0" 2'-6" 2'-0" 1'-91 4" 3'-83
4"
#57 STONE
GRADE1'
-1
1 2"
DOWELS
TO MATCH
VERTICAL
REINF.
#6 @ 12" C/C E.W T&B
#8 @ 6" C/C
VERTICAL E.F
#6 @ 6" C/C
HORIZ. E.F.
#9 @ 4" C/C T&B
#7 @ 6" C/C T&B
#6 @ 6" C/C T&B
#4 @ 6" C/C
CLOSED TIES
A S511 S511
STAIR BEAM SECTION
SCALE: 3/4" = 1'-0"
A S511 S511
F.F.E.
#4 @ 6" C/C
1'-0"
CONT. #6
4'-0"
2' -0
1/2" EXP JT
(4) #4 CLOSED TIES
@ 6" C/C
CONT. #9 @ 4" C/C
#5 @ 6" C/C
SINGLE LEG
STIRRUPS
2' -0
1'-2"
(4) #5 CONT.
#4 @ 4" C/C
CLOSED TIES
2" CHAMFER
#5 @ 6" C/C
CLOSED TIES
(4) #5 CONT.
2"
CLR.
1'-8"
1' -8
3 4"
BASE PLATE FOR
FUTURE RAPPEL TIE OFF
SCALE: 1 1/2" = 1'-0"
1'-0"
1' -0
1' -4
1'-4"
1'-0" 2"2"
8" 1"
16"x16"x1" A36
BASE PLATE
F1554 A36 (HDG) ANCHORS16"x16"x1" A36
BASE PLATE
4"*VARIES *VARIES
1/2" A36 STEEL
LINER PLATE
TYPICAL PARAPET DETAIL
AT SCUPPER
SCALE: 3/4" = 1'-0"
3' -6
1' -0
2'-0"
#5's @ 8" C/C
CONT. E.F.
#5's @ 8" C/C E.F.
(3) ADDITIONAL
#5's @ 8" C/C
1'-8" 1'-8"
#4 SINGLE LEG
STIRRUPS @ 4" C/C
ON HORIZ. BARS OVER
OPENING WIDTH
IN-WALL PILASTER IN-WALL PILASTER
#9's @ 6" C/C
VERT. BARS
(2) #5 CLOSED TIES
@ 4" C/C
SEE DETAIL
ON THIS SHEET.
TYPICAL SCUPPER
PILASTER SECTION
SCALE: 3/4" = 1'-0"
2'-6"
1' -6
#9's @ 6" C/C E.F.
SCUPPER
EDGE
(2) #5 CLOSED TIES
@ 4" C/C
(3) ADDITIONAL
#9's ON EACH
SIDE FACE
ROUGHENED JT.
(1/4" AMPLITUDE)
(TYP)
ROUGHENED JT.
(1/4" AMPLITUDE)
(TYP)
14/16
1"x1"
PLUG WELD
(SEE S-506) 1" - 7 3/4"
CERTIFIED FINAL
W
2Q R
R
NOTE: PLATE-TO-PLATE GAP TO BE NO GREATER THAN
1/8". NO BUTT WELDING REQUIRED FOR LINER
PLATES.
Am en dm en t 0
W
2Q R
R
Pl an s-
M
FLEXIBLE CONDUIT CONNECTION
CONDUCTOR AND 1 #12 GREEN EQUIPMENT GROUND IN 1/2" CONDUIT.
NO HASH MARKS INDICATES 1 #12 PHASE CONDUCTOR, 1#12 GROUNDED
FLOOR UNLESS NOTED OTHERWISE.
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED FLUSH IN THE
FLUSH FLOOR MOUNTED NEMA 5-20 DUPLEX RECEPTACLE
UNLESS NOTED OTHERWISE
BASED ON MANUFACTURERS RECOMMENDATIONS
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE. (AC INDICATES ABOVE COUNTER)
JUNCTION BOX ("F" INDICATES FLOOR MOUNTED, "CLNG" INDICATES CEILING MOUNTED)
UNFUSED DISCONNECT SWITCH. SIZE AS SHOWN
FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT
SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER
SWITCH AS INDICATED.
MOTOR, SIZE AS SHOWN.
J
F
POWER
ARROW INDICATES HOMERUN TO PANEL "A", CIRCUIT 21.
EXPOSED UNLESS NOTED OTHERWISE ON PLAN.
SEE DESCRIPTION OF HASH MARKS.A-21
WIRING
HASH MARKS INDICATES NUMBER OF CONDUCTORS RAN IN CONDUIT.
FLUSH FLOOR MOUNTED NEMA 5-20 QUAD RECEPTACLE
UNLESS NOTED OTHERWISE
RECESSED MOUNTED PANELBOARD
250 VOLT, 1ø, 20 AMP RECEPTACLE, (L6-20R)
GROUNDING
TELECOMMUNICATIONS
GENERIC LIGHTNING PROTECTION CONDUCTOR
SEE LIGHTNING PROTECTION SHEET(S) FOR SPECIFIC
GUIDENCE
AIR TERMINAL
GROUNDING ROD
A AMPERE
ACS ACCESS CONTROL SYSTEM
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
1/C ONE CONDUCTOR
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CU COPPER
EF EXHAUST FAN
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
HACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
J JUNCTION BOX
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
MCB MOLDED CASE CIRCUIT BREAKER
MH METAL HALIDE
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PH PHASE
PIR PASSIVE INFRARED
RGS RIGID GALVANIZED STEEL
SM SINGLE MODE
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
UNO UNLESS NOTED OTHERWISE
V VOLT
VA VOLTAMPERE
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WATER PROOF
XFMR TRANSFORMER
ABBREVIATIONS
INTERIOR CCTV CAMERA
EXTERIOR CCTV CAMERA
APL APPROVED PRODUCT LIST
NDAA NATION DEFENSE AUTHORIZATION ACT
GRC GALVANIZED RIGID CONDUIT
TGB TELECOMMUNICATION GROUNDING BUSBAR
MGB MAIN GROUNDING BUSBAR
VSS VISUAL SECURITY SYSTEM
UPS UNINTERRUPTIBLE POWER SOURCE
AC ABOVE COUNTER, 42"AFF UNLESS OTHERWISE INDICATED
AGM ARMY GOLDEN MASTER
NVR NETWORK VIDEO RECORDER
UHD ULTRA HIGH DEFINITION
POE POWER OVER ETHERNET
MBPS MEGABYTES PER SECOND
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
DISA DEFENSE INFORMATION SYSTEMS AGENCY
SFP SMALL FORM-FACTOR PLUGGABLE
QPI QUICK PATH INTERCONNECT
RPM ROTATIONS PER MINUTE
GBPS GIGABYTES PER SECOND
GSA GENERAL SERVICE ADMINISTRATION
MP MEGA PIXELS
MPTL MODULAR PLUG TERMINATED LINK
IR INFRARED
DIN DEUTSCHES INSTITUT FUR NORMUNG
(GERMAN INSTITUTE FOR STANDARDIZATION)
BMS BALANCED MAGNETIC SWITCH
KAIC THOUSAND AMPERE INTTERUPTING CAPACITY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 3:18:34 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
E-001
LE
G
EN
D
A N
D A
BB
R
EV
IA
TI
O
N S
W . Y
O U
N G
W . Y
O U
N G
J.
S
C H
EN
KE
N
FE
LD
ER
J.
W
AL
TE
R S
JA
N
U
AR
Y
W
2Q R
R
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
VESTIBULE
RECEPTION /
TELLER WINDOW
103LARGE
CONFERENCE
ROOM
ADMIN OFFICE
ADMIN OFFICE
ADMIN. OFFICE
115 ADMIN. OFFICE
"OUT-OF-PLAY"
COM. ROOM
"IN-PLAY" COM.
ROOM
WOMENS
RESTROOM
MENS
RESTROOM
KITCHENETTE /
CAFETERIA
CONSULAR
OFFICE
ELEV. SHAFT
STAIR
CORRIDOR
CONSULAR
OFFICE
CONSULAR
OFFICE
ATRIUM
PP-OUT
PP-IN
PP-OUT
1,5 PP-OUT
PP-OUT
PP-OUT
1,5
OU-2OU-1
A A
PP-OUT
1. FOR SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES, SEE
SHEET E-001.
2. FOR PANEL SCHEDULES, SEE SHEETS E-601.
3. FOR ELECTRICAL ONE-LINE, SEE SHEET E-601.
4. PROVIDE #10 AWG COPPER CONDUCTORS FOR HOMERUNS
EXCEEDING 100 FEET IN LENGTH AND #8 AWG COPPER
CONDUCTORS FOR HOMERUNS EXCEEDING 150 FEET IN LENGTH
UNLESS OTHERWISE NOTED.
5. ALL INTERIOR CONDUIT TO BE GRC UNLESS NOTED OTHERWISE.
6. ALL RECEPTACLES TO BE RECESSED AND EQUPPIED WITH A COVER
TO PROTECT FROM DIRT/DEBRIS.
7. ALL RECEPTACLES AND CONDUIT ARE TO BE INSTALLED WITHIN THE
WALLS OF THE BUILIDNG FOR PROTECTION AGAINST BLASTING.
GENERAL NOTES
"OUT-OF-PLAY"
COM. ROOM
"IN-PLAY" COM.
ROOM
PP-OUT
PP-IN
OU-2OU-1
A A
PP-OUT
10,12PP-OUT
PP-IN
1,3
PP-IN
PP-OUT
15,17,19
PP-OUT
16,18,20
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 4:36:30 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
E-101
PO
W
ER
P
LA
N
ST
F
LO
O R
W . Y
O U
N G
W . Y
O U
N G
J.
S
C H
EN
KE
N
FE
LD
ER
J.
W
AL
TE
R S
JA
N
U
AR
Y
W
2Q R
R
1/8" = 1'-0"A1 FIRST FLOOR POWER PLAN
KEY NOTES
1 MINIMUM 24" X 2" X 1/4" TGB SEE SHEET E-501 FOR GROUNDING
SYSTEM DIAGRAM.
2 MINIMUM 24" X 4" X 1/4" MGB SEE SHEET E-501 FOR GROUNDING
SYSTEM DIAGRAM & MGB DETAIL.
3 VERIFY CONNECTION/TERMINATION REQUIREMENTS OF HVAC
EQUIPMENT WITH MECHANICAL CONTRACTOR. SEE SHEET M-101
FOR DETAILS.
4 DEDICATED RECEPTACLE FOR IN-PLAY WORKSTATION FOR VSS
SYSTEM. RECEPTACLE TO CONNECT TO UPS LOCATED IN THE
IN-PLAY TELECOM CABINET VIA CORD AND PLUG END. SEE SHEET
TY-106 FOR WORKSTAION AND IN PLAY CABINET ELEVATION.
3/8" = 1'-0"A5
FIRST FLOOR POWER PLAN-TELECOM
ROOMS
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
LOBBY
USAID OPEN
OFFICE
303 OFFICE
SCIF
305AOFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
STAIR
ELEV. SHAFT
ATRIUM
"BUBBLE"
305B
PP-OUT
PP-OUT
11 PP-OUT
OFFICE
1. FOR SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES, SEE
SHEET E-001.
2. FOR PANEL SCHEDULES, SEE SHEETS E-601.
3. FOR ELECTRICAL ONE-LINE, SEE SHEET E-601.
4. PROVIDE #10 AWG COPPER CONDUCTORS FOR HOMERUNS
EXCEEDING 100 FEET IN LENGTH AND #8 AWG COPPER
CONDUCTORS FOR HOMERUNS EXCEEDING 150 FEET IN LENGTH
UNLESS OTHERWISE NOTED.
5. ALL INTERIOR CONDUIT TO BE GRC UNLESS NOTED OTHERWISE.
6. ALL RECEPTACLES TO BE RECESSED AND EQUPPIED WITH A COVER
TO PROTECT FROM DIRT/DEBRIS.
7. ALL RECEPTACLES AND CONDUIT ARE TO BE INSTALLED WITHIN THE
WALLS OF THE BUILIDNG FOR PROTECTION AGAINST BLASTING.
GENERAL NOTES
OFFICE
216 RSO OFFICE
OFFFICE
OFFICE
POL-ECON
OFFICE
POL-ECON
OFFICE
POL-ECON
OFFICE
CORRIDOR
PUBLIC AFFAIRS
OFFICE
OFFICE
OFFICE
PUBLIC AFFAIRS
OFFICE
STAIR
ELEV. SHAFT
ATRUIM
PP-OUT
PP-OUT
PP-OUT
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 4:36:36 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
E-102
PO
W
ER
P
LA
N
N
D
R
D F
LO
O
R
W . Y
O U
N G
W . Y
O U
N G
J.
S
C H
EN
KE
N
FE
LD
ER
J.
W
AL
TE
R S
JA
N
U
AR
Y
W
2Q R
R
1/8" = 1'-0"A5 THIRD FLOOR POWER PLAN
1/8" = 1'-0"A1 SECOND FLOOR POWER PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
#3/0
GENERAL NOTES
1. EQUIPMENT TO BE FURNISHED & INSTALLED BY
NOLIN RECC. SEE SHEET EU001 FOR DIVISION OF
RESPONSIBILITY.
2. COORDINATE ROUGH-IN WITH NOLIN RECC. SEE
SHEET EU001 FOR DIVISION OF RESPONSIBILITY.
SEE SHEET EU502 FOR POWER DUCTBANK DETAIL.
3. TRANSITION POINT FROM PVC TO GRC 5' OUTSIDE
THE BUILDING WALL LINE IN ORDER TO ADDRESS
BUILDING SETTLING.
1. SEE SHEET EU001 FOR EXTERIOR SITE NOTES AND DIVISION
OF RESPONSIBILITY.
2. SEE SHEET EU501 FOR DUCT BANK DETAILS.
3. SEE SHEET SERIES CU FOR SITE DRAWINGS.
4. FAULT CURRENT AMP INTERRUPTING CAPACITIES ARE
MINIMUM. IF STANDARD EQUIPMENT RATING IS GREATER,
PROVIDE STANDARD RATING.
5. PROVIDE FULL LENGTH 100% RATED NEUTRAL BAR AND A
GROUNDING BAR IN EACH SECTION OF THE
SWITCHBOARD/PANELBOARDS. PROVIDE MAIN BONDING
JUMPER IN ACCORDANCE WITH NFPA 70 PARAGRAPH 250.24
(B).
6. PROVIDE ADDITIONAL SPARES AND SPACES AS SHOWN ON
PANEL SCHEDULES ON THIS SHEET.
7. PROVIDE SURGE PROTECTION FOR EITHER THE CIRCUIT OR
THE PANEL THE CIRCUIT IS CONNECTED TO FOR ALL CIRCUITS
EXITING THE BUILDING SUCH AS BUT NOT LIMITED TO
EXTERIOR LIGHTING AND CATV EQUIPMENT CIRCUITS. NOT
ALL REQUIRED SURGE PROTECTIVE DEVICES (SPDS) ARE
SHOWN IN PANEL SCHEDULES. SPDS MAY BE REQUIRED IN
ADDITONAL LOCATIONS BASED ON FINAL EQUIPMENT
INSTALLED AND ITS LOCATION. SURGE PROTECTIVE DEVICES
SHALL BE FED BY A DEDICATED BREAKER AND INSTALLED
EXTERNAL TO PANELBOARDS IN A SEPARATE ENCLOSURE
AND EXTERNAL TO DISTRIBUITION EQUIPMENT OR IN A
SEPARATE METAL CLAD COMPARTMENT OF THE
DISTRIBUITION EQUIPMENT.
8. THE CONTRACTOR SHALL SUBMIT ARC FLASH CALCULATIONS
BASED ON THE INSTALLED EQUIPMENT SIZINGS, RATINGS,
ARRANGEMENTS, AND SETTINGS. THE CALCULATIONS SHALL
BE EXECUTED IN EASYPOWER AND SUBMITTED AS PART OF
THE FAULT CURRENT AND PROTECTIVE COORDINATION
STUDY ALONG WITH THE SYSTEM MODEL. CONTRACTOR
SHALL PROVIDE ARC FLASH LABELS ON ALL PANELS
INDICATING THE ARC FLASH HAZARD LEVEL BASED ON THE
RESULTS FROM THE COORDINATION STUDY. ADJUST AIC
RATINGS OF EQUIPMENT REQUIRED BASED ON ACTUAL
EQUPMENT RATINGS. IMPENDANCE OF TRANSFORMER
AFFECTS RATING.
9. SERIES RATED AND PLUG-IN CIRCUIT BREAKERS ARE
UNACCEPTABLE.
10. PROVIDE ARC FLASH ANAYLYSIS AND WARNING SIGNS ON
SWITCHBOARDS, PANELBOARDS, INDUSTRIAL CONTROL
PANELS, METER SOCKET ENCLOSURES, AND MOTOR
CONTROL CENTERS AS REQUIRED PER NFPA 70 (NEC)
ARTICLE 110.16. REFERENCE NFPA 70 ARTICLE 110.16, NFPA
70E ARTICLE 130.3, AND UFC 3-560-01, ELECTRICAL SAFETY,
O & M.
11. PROVIDE ELECTRONIC TRIP BREAKERS WITH LSI SETTINGS
FOR ALL SWITCHBOARD/ PANELBOARD BREAKERS SERVING
SUB-PANELS.
DM
SPD
22KAGROUND BAR,
IN ENCLOSURE
R
AT
IN
G
P
ER
M
AN
U
FA
C
TU
R
ER
EXTERNAL
GROUND
SYSTEM
2 31
MAIN
100A/3P
A/
3P
A/
3P
METERED MAIN DISTURIBUTION PEDESTAL, 100A, 208/120V, 22 KAIC, 3 PHASE, WITH FULL NEUTRAL & GROUND BUSES, NEMA 3R
EXISTING POWER POLE.
CONTRACTOR TO PROVIDE
DUCTS AND ITEMS SHOWN ON
DRAWINGS AS CONTRACTOR
PROVIDED.
FUSE
208V
12.47 KV
KEY NOTES
RANGE 5 TRANSFORMER
75 KVA UTILITY
TRANSFORMER WITH
METER, CT
COMPARTMENT, AND ALL
RELATED COMPONENTS
PROVIDED
(SIZED FOR FUTURE
EXPANSION)
8 A
M1
SP
AC
E
ID# FEEDER SCHEDULE
(1) SET OF (4-#2, 1-#8 G IN 2" SCHEDULE 40 PVC)
(1) SETS OF (3-#4, 1-#6 G IN 1-1/4" SCHEDULE 40 PVC)
M1
(4) 4" SCHEDULE 40 PVC CONDUIT
(1) SET OF (4-#2, 1-#8 IN 4" SCHEDULE 40 PVC)
EXISTING RANGE 4
TRANSFORMER PAD.
NEWLY FURNISHED
CONDUIT TO CONNECT TO
EXISTING CONDUIT.
PANEL
PP-OUT
PANEL
PP-IN
A/
3P
A/ 3P
NEMA 3R ENCLOSURE
MANUAL SWITCH, 4-POLE,
PROVIDED BY CONTRACTOR
(BASIS OF DESIGN: PSI
MTSBBGTB)
GENERATOR
HOOKUP
CABINET
4 (1) SET OF (4-#2, 1-#8 IN 2" GRC)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 3:19:34 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
E-601
O N
E-
LI
N E
D
IA
G R
AM
S
AN
D
P
AN
EL
S
C H
ED
U
LE
W . Y
O U
N G
W . Y
O U
N G
J.
S
C H
EN
KE
N
FE
LD
ER
J.
W
AL
TE
R S
JA
N
U
AR
Y
W
2Q R
R
NTSC5 ONE-LINE DIAGRAM
GENERATOR HOOKUP CABINET
MAIN DISTRIBUTION PEDESTAL
Notes:
Total Est. Demand Current: 38 A
HEAT 2810 VA 2810 VA Total Conn. Current: 42 A SPEC 3593 VA 2156 VA Total Est. Demand: 13608 VA RCPT 7740 VA 7740 VA Total Conn. Load: 15044 VA
LIGHTS 974 VA 974 VA
Load Classification Connected Load Estimated Demand Panel Totals
Total Amps: 44 A 42 A 40 A Total Load: 5293 VA 5008 VA 4745 VA
23 24
21 SPEC, CCTV POLES 1,2,3 20 A 1 270 VA 22
19 468 VA 468 VA 20
17 468 VA 468 VA 18
HEAT, OU-2 20 A 3
468 VA 468 VA
3 20 A HVAC, OU-1
13 RCPT, 306, 305, 304, CORR 20 A 1 360 VA 974 VA 1 20 A LIGHT, EXT LIGHTS 14
11 RCPT, -313, 312, 311, 303, 302, CORR,... 20 A 1 1080 VA 1664 VA 12
9 RCPT, - 310, 309, 307, CORR 20 A 1 900 VA 1664 VA
2 20 A SPEC, OUT-PLAY DATA RACK
7 RCPT, 212, 210, 209, 208, CORR 20 A 1 900 VA 1080 VA 1 20 A RCPT, 215, 214, 213, 203, 202, 201 8
5 RCPT, 118, 117, 116, 115, CORR 20 A 1 720 VA 360 VA 1 20 A RCPT, 112, 113 6
3 RCPT, 108,107,105,CORR 20 A 1 360 VA 900 VA 1 20 A RCPT, 111,110,109,106 4
1 RCPT, 121,104,103,100,CORR 20 A 1 540 VA 540 VA 1 20 A RCPT, - 207, 206, 205, 204, CORR 2
CKT Load Name Trip Poles A B C Poles Trip Load Name CKT
Notes:
Enclosure: NEMA 1 MCB Rating: 60 A Mounting: SURFACE Wires: 4 Mains Rating: 100 A
Supply From: Phases: 3 Mains Type: MAIN CB Location: "OUT-OF-PLAY" COM. ROOM 113 Volts: 120/208 Wye A.I.C. Rating: 10,000 AMPS SYMMETRICAL
Branch Panel: PP-OUT
Notes:
Total Est. Demand Current: 6 A
Total Conn. Current: 10 A Total Est. Demand: 2105 VA Total Conn. Load: 3508 VA
SPEC 3508 VA 2105 VA
Load Classification Connected Load Estimated Demand Panel Totals
Total Amps: 16 A 16 A 2 A Total Load: 1664 VA 1664 VA 180 VA
23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8
5 SPEC, IN-PLAY ACS CABINET 20 A 1 180 VA 6
3 1664 VA 4
SPEC, IN-PLAY DATA RACK 20 A 2 1664 VA 2
CKT Load Name Trip Poles A B C Poles Trip Load Name CKT
Notes:
Enclosure: NEMA 1 MCB Rating: 60 A Mounting: SURFACE Wires: 4 Mains Rating: 100 A
Supply From: Phases: 3 Mains Type: MAIN CB Location: "OUT-OF-PLAY" COM. ROOM 113 Volts: 120/208 Wye A.I.C. Rating: 10,000 AMPS SYMMETRICAL
Branch Panel: PP-IN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
A A
AA
PP-OUT
#2 BARE
COPPER WIRE
TO GROUND
ROD
FINISHED GRADE
GROUNDING
STUD
COVERED
HANDHOLE
#8 BARE COPPER
GROUNDING WIRE
TO LIGHT FIXTURE
CONDUIT & WIRING AS
SHOWN ON DRAWINGS
SEE "LIGHT
POLE BASE
DETAIL" THIS
SHEET.
SEE THIS SHEET
FOR THE LIGHTING
FIXTURE TYPE A
DETAIL
SQUARE STRAIGHT
ALUMINUM POLE WITH
DARK BRONZE FINISH
FOR CONTINUATION
SEE DRAWINGS
FINISHED GRADE
2" CHAMFER
3/4" X 8'-0"
COPPERWEL
D GROUND
ROD
2" MIN.
POLE
CONDUIT. SEE
SITE PLANS
(TYP.)
#2 BARE COPPER
GROUNDING
CONDUCTOR
CONCRETE BASE WITH 12
4 BARS VERTICAL SPACED
AT 30° AND WITH #2 TIES
12" O.C. 19" DIAMETER
ANCHOR BOLTS
AND TEMPLATE
PROVIDED WITH
POLE
3' -0
6'
-0
FOR AC AND AF FIXTURES
2'-0" DIA.
4'-0" DIA.
FEATURES
LAMP TYPE: LED, 4000K
PROFILE: 25,871 LUMENS @ 2.03 A
OPTICS: 5WQ, HIGH-EFFICIENCY,
INJECTION-MOLDED ACCULED
LAMP LIFE: 416,000 HOURS
DRIVER: LED 0-10V
GENERAL
HOUSING: HEAVY-WALL, DIE-CAST ALUMINUM
MOUNTING: POLE MOUNTED
ELECTRICAL: 120 V
FINISH: POLYESTER POWDER COAT
1. FOR SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES REFER
TO SHEET EU001.
2. FOR PANEL SCHEDULES REFER TO SHEETS E-601.
3. COORDINATE LIGHTING SEQUENCE OF OPERATIONS AND SWITCH
LOCATIONS WITH CONTRACTING OFFICER.
4. CONTRACTOR IS RESPONSIBLE FOR PROVIDING CONTROLS
SENSORS, CABLING, AND ANY OTHER PROVISIONS REQUIRED TO
IMPLEMENT A FULLY FUNCTIONAL LIGHTING SYSTEM AS
DESCRIBED IN THIS DESIGN.
5. ALL WIRING SHALL BE 2-#2 AWG + 1-#12 AWG GND IN 1/2" PVC
UNLESS OTHERWISE NOTED OR REQUIRED DUE TO VOLTAGE
DROP.
GENERAL NOTES
FEATURES
TECHNOLOGY: PROGRAMMABLE NETWORK
TIME CLOCK
16 PROGRAMMABLE EVENTS PER DAY
OPTIONS
NOM. DIMENSIONS 197 mm x 127 mm x 76 mm
GENERAL DESCRIPTION
HOUSING: CASE, NEMA 1, DRAWN STEEL,
SIDE HNGED DOOR WITH LOCK AND KEY
MOUNTING: WALL MOUNTED
ELECTRICAL: 120V
FINISH: PAINTED GRAY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 3:31:45 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
EU101
SI
TE
L
IG
H
TI
N G
P
LA
N
D
ET
AI
LS
W . Y
O U
N G
W . Y
O U
N G
J.
S
C H
EN
KE
N
FE
LD
ER
J.
W
AL
TE
R S
JA
N
U
AR
Y
W
2Q R
R
1/16" = 1'-0"A1 EXTERIOR LIGHTING PLAN
N.T.SA6 SITE LIGHTING POLE
N.T.S.A8 SITE LIGHTING POLE BASE
1 1/2" = 1'-0"F6 FIXTURE TYPE A KEY NOTES
1 FIXTURE TO BE MOUNTED IN ACCORDANCE WITH MANUFACTURERS
INSTRUCTIONS. SEE POLE DETAIL ON THIS SHEET. (TYPICAL)
2 PROVIDE PROGRAMMABLE TIMECLOCK FOR EXTERIOR LIGHTING
CONTROL. SEE DETAIL D8 ON THIS SHEET.
12" = 1'-0"D8 WALL MOUNTED TIME CLOCK
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
GENERAL SHEET NOTES
SHEET KEYNOTES
3. SEE SHEET SERIES CU101-CU115 FOR SITE DRAWINGS.
2. SEE SHEET EU001 FOR DIVISION OF RESPONSIBILTY.
DISCREPENCIES PRIOR TO INSTALLATION.
SHOULD BE NOTIFIED OF ANY CONFLICTS OR
ALL EXISTING UTILITIES. THE CONTRACTING OFFICER
COORDINATING ALL UTILITIES AND FIELD VERIFYING
1. THE CONTRACTOR IS RESPONSIBLE FOR
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
S
U E D
A T
E
S O
L
IC
IT
A T
IO
N N
O
C O
N T
R A
C T N
O
S
IZ
E
S U
B M
IT
T E
D B
Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
L O
U
IS
V
IL
L E D
IS
T R
IC
T
D
R
M A
R T
IN
L
U T
H E
R K
IN
G J
R P
L
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
F T
K N
O X T
R A
IN
IN
G T
A R
G E
T S
T R
U C
T U
R E
F T
K N
O X
K E
N T
U C
K Y
P N
F
Y P
L O
U
IS
V
IL
L E
K E
N T
U C
K Y
CERTIFIED FINAL
W
Y O
U N
G
W
Y O
U N
G W
Q R
R
A N
S I
D
J A
N U
A R
Y
M A
R
A M
E N
D M
E N
T
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
EU503
W
Y O
U N
G
W
Y O
U N
G
E L E
C T
R
IC
A L U
T
IL
IT
Y D
E T
A
IL
S
2'
2'
4'
ROUTE 4
" RACEWAYS
TO "OUTPLAY" TELECOM
RACK. TERMINATE FIBER
IN SEPERATE BUILKHEAD ON
FAR RIGHT IN FIBER TERMINATION
CABINET. TERMINATE POWER
WITH CORD AND CAP AND PLUG INTO
RACK MOUNT UPS.
RANGE 4 OFFICE
POLE #1 POLE #2 POLE #3
PTZ POE+
(TYPICAL)
MEDIA CONVERTER
WITH SFP TO RJ-45
IN RESPECTIVE SWITCH
FURNISH POWER
(TYPICAL)
POLE #1 POLE #2
"OUT-PLAY"
SM OSP LOOSE TUBE
IN 1-1/4" HDPE WITH POWER.
SEE CU SHEETS FOR ADDITIONAL INFORMATION
2 SM OSP LOOSE TUBE
SEE SHEE CU11X
(2) #8, (1) #12 G
2 SM OSP LOOSE TUBE
SEE SHEE CU11X
2 SM OSP LOOSE TUBE
SEE SHEE CU11X
FURNISH AND INSTALL MEDIA CONVERTERS
WITH SFP'S IN RANGE FOUR OFFICE AND FURNISH
CAT6 PATCH CABLES TO CONNECT TO OWNER'S
EXISTING SECURITY SYSTEM. COORDINATE LICENSES
FOR CONTINUATION
SEE SHEET TY601
DATA RACK
POLE #3
4. SEE DETAIL A1 ON THIS SHEET FOR POLE DETAIL.
3. SEE SHEET CU114 FOR POLE #3 LOCATION.
2. SEE SHEET CU113 FOR POLE #2 LOCATION.
1. SEE SHEET CU112 FOR POLE #1 LOCATION.
TARGET TRAINING STRUCTURE
4 4 4
E1
POLE AND POLE MOUNTED PTZ CAMERA ONE-LINE
NTS
A5
OUTPLAY EXTERIOR BACKBONE
NTS
A1
POLE AND POLE MOUNTED PTZ CAMERA DETAIL
NTS
(TYPICAL)
CAT6 IN 3/4" GRC
CAMERA ON POLE.
MOUNT GROUND 180 DEGREE FROM
CONNECTED TO POLE BUTT PLATE.
STAPLED ENTIRE LENGTH OF POLE
2' AIR TERMINAL.WITH #4 SOLID CU
CAMERA ON POLE.
MOUNT GROUND 180 DEGREE FROM
CONNECTED TO POLE BUTT PLATE.
STAPLED ENTIRE LENGTH OF POLE
2' AIR TERMINAL.WITH #4 SOLID CU
45' WOODEN CLASS 3 SP UTILITY POLE
TERMINATED WITH MEYRS HUBS
3/4" GRC WITH SUPPORTS AT 4'
-SURGE ARRESTOR EARTHED
-120V DUPLEX OUTLET
-POWER SUPPLY FOR INJECTOR
-20AMP TOGGLE SWITCH AND FUSE
-CAT6 TO CAMERA WITH MPTLS
-90W MIDSPAN POWER INJECTOR
-MEDIA CONVERTER WITH SPF MODULE
-FO SPLICE TRAY AND PIGTAIL
HOLD INTERNAL COMPONENTS
FCB CHNF N4X SIZED TO
DEPTH WITH KO AND COMPLY WITH NESC.
OTHER THAN FIRM SOIL COORDINATE BURIAL
BURIAL DEPTH TO 6.5'. IF SOIL CONDICTIONS
OVER EXISTING MULTIMODE FIBER.
OWNER TO PATCH POLE MOUNT CAMERAS
MEDIA CONVERTER PAIR TO ALLOW SYSTEM
FURNISH SEPERATE SWITCH AND MULTIMODE
WORKSTATION AND COMMISSION.
INSTALL NVR AND SOFTWARE AND VIEWING
TO CONNECTING TO TARGET STRUCTURE.
NEW SWITCH WITH SINGLE MODE SFP
TO RANGE 4 OFFICE
FOR POLE CAMERAS AND PATCH
PATCH IN FIBER OPTIC PATCH PANEL
STRUCTURE
MODE SFP CONNECTING TO TARGET
NEW MEDIA CONVERTER WITH SINGLE
WITH SYSTEM OWNER. (TYPICAL)
J S
C H
E N
K E
N F
E L
D E
R
J
W A
L T
E R
S
24 STRAND SINGLE MODE FIBER IN 1-1/4" PE
PATCH FIBER THROUGH
CIRCUIT 22
TO PANEL PP-OUT
ROUTE CONDUCTORS
(2) #8, (1) #12 G (2) #8, (1) #12 G
W
2Q R
R
Pl an s-
F B
C
A A
C
B
202322
J
C B
AB
B
5 6
7 8
5A
B
G
C
D
A
A A
D B
B B
D J
C B
5 6
GENERAL NOTES
1. SEE SHEET E-001 FOR TELECOMMUNICATIONS LEGEND AND
SYMBOLS.
2. SEE SHEET TY601 FOR IN-PLAY/OUT-PLAY VSS ONE-LINE DIAGRAM.
3. SEE SHEET TY501 AND TY502 FOR VSS DETAIL SHEET.
4. INSTALL OUT-PLAY CAMERA SYSTEM INCLUDING CABLING,
CONDUIT, OUT-PLAY CABINET, AND OUT-PLAY CAMERAS. ROUGH-IN
IN-PLAY CAMERA SYSTEM CABLING, CONDUIT, AND IN-PLAY
CABINET. THE IN-PLAY CAMERAS ARE TO BE INSTALLED BY
OTHERS.
5. ALL PENETRATIONS ARE TO BE PROPERLY FIRESTOPPED.
RESEALABLE, RE-ENTERABLE, MECHANICAL FIRESTOPPING
ASSEMBLIES MUST BE USED FOR ALL FLOOR SLEEVES AND FOR
PENETRATIONS OF FIRE RATED WALLS.
6. ALL CONDUITS, RACKS, CABLE TRAYS TO BE PROPERLY BONDED
AND GROUNDED.
7. ALL HORIZONTAL CABLING TO BE CAT6 RATED AND CMP LISTED
WITH BLUE CABLE JACKET UNLESS OTHERWISE NOTED.
8. CONDUITS ARE DRAWN DIAGRAMATICLLY. CONTRACTOR IS
RESPONSIBLE FOR DETERMINING BEST POSSIBLE PATH AND
ORIENTATION OF CONDUIT. JUNCTION BOXES ARE TO BE PARTIAL
EXPOSED FOR ACCESSIBLITY.
9. ALL CONDUIT IS TO BE INCASED/RECESSED WITHIN THE BUILIDNG
STRUCTURE UNLESS NOTED OTHERWISE.
10. SEE SHEET TY502 FOR ACS CONDUIT SCHEDULE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
D R
AW
IN
G C
O D
E:
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
AP
PR
CERTIFIED FINAL
FT
K
N O
X, K
EN
TU
C
KY
SO
F
TR
AI
N
IN
G T
AR
G
ET
S
TR
U
C
TU
R E
PN
, F Y2
1, P
LO
U
IS
VI
LL
E
D
IS
TR
IC
T
3/16/2021 3:19:44 PM
C:\Users\H2EDDWCY\Documents\477836_v2018_TrainingTargetStructure_E_H2EDDWCY.rvt
TY101
PL
AN
V
IE
W V
SS
F
F2
J.
W
AL
TE
R S
J.
W
AL
TE
R S
J.
S
C H
EN
KE
N
FE
LD
ER
W . Y
O U
N G
JA
N
U
AR
Y
W
2Q R
R
1/8" = 1'-0"A5 SECOND FLOOR TELECOMM PLAN
1/8" = 1'-0"A1 FIRST FLOOR TELECOMM PLAN
KEY NOTES
1 SEE DETAIL A5 ON SHEET TY103 FOR EQUIPMENT LAYOUT.
2 CAT6 CABLEING WITH ENTER CABLE TRAY AND DISTRIBUTE TO DATA
RACKS.
3 IN-PLAY ROUGH-IN AND OUT-PLAY CAMERAS ARE TO BE MOUNTED
ABOVE DOORWAYS AND/OR CORNERS IN ACCORDANCE WITH SHEET
TY502 DETAIL A5. SEE TY601 FOR ONE-LINE. (TYP)
4 IN-PLAY ROUGH-IN AND OUT-PLAY CAMERAS ARE TO BE MOUNTED
ON WALLS/SURFACES IN ACCORDANCE WITH SHEET TY502 DETAIL
A1. SEE TY601 FOR ONE-LINE. (TYP)
5 SEE SHEET TY502 DETAIL E1 FOR OUT-PLAY CAMERA DETAIL. (TYP)
6 SEE SHEET TY502 DETAIL E5 FOR IN-PLAY ROUGH-IN DETAIL. (TYP)
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
M
AR
W
2Q R
R
Pl an s-
E
B
B
D
B
B
A A
33 35
C
B
3 4
37 38
A
B
A
PTZ CONNECTION FURNISH
POE+ PORT OR 60W INJECTOR
(TYPICAL)
A
C
GENERAL NOTES
1. SEE SHEET E-001 FOR TELECOMMUNICATIONS LEGEND AND
SYMBOLS.
2. SEE SHEET TY601 FOR IN-PLAY/OUT-PLAY VSS ONE-LINE DIAGRAM.
3. SEE SHEET TY501 AND…
This is the start of the file's text. The full file is on GovTribe.