This document provides details for a federal solicitation seeking repair of airfield lighting at Grissom Air Reserve Base in Indiana. The solicitation will be for a firm-fixed-price construction contract awarded based on lowest price. Work will involve replacing taxiway and runway lighting circuits and conduit, as well as windsocks at each end of the runway. Services required include replacing airfield lighting cables, duct banks, and subsystem components such as edge lights, distance remaining signs, approach lights, and precision approach path indicators to standards specified in UFC 3-535-01. The contract period is estimated at 540 calendar days. The solicitation will be publicly posted and open to all qualified contractors, with a magnitude between $5-10 million. The selected awardee will be determined through a sealed low-bid process managed by the Department of the Army Corps of Engineers Louisville District.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912QR20B0024 (Abtsract of Bidders).pdf | ||
| W912QR20B0024_Specs-0002.pdf | ||
| W912QR20B0024-0001.pdf | ||
| W912QR20B0024_Plans-0000.pdf | ||
| W912QR20B0024_Specs-0000.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL
CIVIL SYMBOL LEGEND
DESCRIPTION
PROPOSED STORM DRAIN (STM)
EXISTING STORM
STAGING AND LAYDOWN AREA
CONSTRUCTION ENTRANCE
FILTER SOCK
INLET PROTECTION
NOTE:
SEE E-SERIES SHEETS FOR MORE ELECTRICAL
SYMBOLS AND NOTES
SD
CONNECT TO EXISTING PIPE OR STRUCTURE
CLEANOUT
CO
EXISTING CATCH BASIN
EXISTING STORM MANHOLE
DRYPIT
PROPERTY EDGE
PL PL
LIMIT OF CONSTRUCTION
A-4
CG503
A-1
CG503
C-4
CG502
A-2
CG504
A-4
CG502
A-3
CG502
EXISTING JUNCTION BOX
SYMBOL
ELECTRICAL SYMBOL LEGEND
DESCRIPTION
EXISTING LED TAXIWAY EDGE LIGHT
EXISTING SIGN (RDR, RUNWAY HOLD, OR TAXIWAY)
P
EXISTING PULL CAN PLAZA
EXISTING RUNWAY EDGE LIGHT.
XXX
NEW PULL CAN PLAZA, SEE DETAILS
# = NUMBER OF CANS
XXX = PULL CAN PLAZA IDENTIFICATION NUMBER
EXISTING MANHOLE
WINDCONE
NEW WIND CONE ON NEW FOUNDATION, CENTER OF DOT
REPRESENTS SITING POINT ON LAYOUT SHEETS.
L-830, 200W, 6.6 AMP ISOLATION TRANSFORMER WITH PVC STAND.
SECONDARY CABLES FROM L-830 TRANSFORMER TO EXISTING
RUNWAY EDGE LIGHT. INSTALL L-823 CABLE IN EXISTING CONDUIT.
EXISTING RUNWAY THRESHOLD LIGHT
RUNWAY SAFETY AREA
TAXIWAY SAFETY AREA
RUNWAY OBJECT FREE AREA
TAXIWAY OBJECT FREE AREA
B
21 3 4 5
21 3 4 5
A
C
D
B
A
C
D
S Dx S Dx S Dx
W
2Q R
B0
4_
Pl an s-
| CTGB15-2012A C-100 |
| Model |