W912QR20B0007Plans-0003.pdf
PDF 4 MB Posted
- Solicitation number
- W912QR20B0007
About this file
This solicitation is for an Invitation for Bid (IFB) to provide placement of modular facilities and leasing of the facilities to support approximately 450 personnel. The U.S. Army Corps of Engineers Louisville District will issue the IFB, numbered W912QR20B0007. The placement of modular facilities must be completed within 300 calendar days of award. The initial lease period is one base year with four option years. The facilities will support personnel at 400 Scott Drive, Scott Air Force Base, Illinois 62225.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MATE LINE
MATE LINE
/4
/2
/2
/2
/2
/4
5/8" 4" 8"
4" 4"
TRAILER EDGE
/2
C L E
A R
1'-0 5/8"
BATTEN STRIP
BATTEN STRIP
5/8" VINYL COATED
GYP. BD.
5/8" VINYL COATED
GYP. BD.
PRE-FINISHED
CORNER GUARD -
MATCH VINYL
COATED GYP BD.
MATE LINE
5/8" PLYWOOD
SHEATHING
2x6 WD STUDS
AT 16" O.C.
5/8" VINYL
COATED GYP.
BD.
STEEL TUBE
COLUMN - SEE
STRUCTURAL
DRAWINGS
/4
2 1/2" 2x WD
FURRING
5/8" VINYL
COATED
GYP. BD.
2x4 WOOD STUDS @ 16" O.C.
PREFINISHED
CORNER
GUARDS
PREFINISHED
CORNER
GUARDS
11 7/8"
5/8" 3 1/2"
1" CLEAR
5/8" 5 1/2"
5/8"
ROOF
122' - 3 1/8"
6" 6"
1/2" 1/2"
FIELD INSTALLED SELF ADHERED
EPDM MEMBRANE AT MATE LINE
EPDM ROOF
MEMBRANE
3/4" PLYWOOD SHEATHING
3/8" GLASS MAT FACED
GYPSUM ROOF DECKING
5/8" VINYL
COATED GYP. BD.
2x6 WD. STUDS
AT 12" O.C.
5/8" PLYWOOD
SHEATHING
2x10 ROOF RAFTERS
R-38 BATT
INSULATION
ELEVATION
123'-7 5/8"
ROOF BEYOND
FIELD INSTALLED 7" +/- WIDE
CONTINUOUS STRIP OF 3/8"
GLASS MAT FACED GYP BD
ROOF SHEATHING OVER FIELD
INSTALLED 3/4" PLYWOOD
SECOND LEVEL
112' - 3 1/4"
2x12 AT 12" AND W8x13 AT COLUMN
1/2" PLYWOOD
SHEATHING
3/4" PLYWOOD
SUBFLOOR
5/8" GYP. BD.
5/8" GYP. BD.
2x6 WD. STUD STRUCT
SHEAR WALL
5/8" PLYWOOD SHEATHING
2x10 @ 24" O.C.
2 LAYERS SOUND
ATTENUATED BATT
INSULATION
3X8 WOOD NAILER
1'-2 1/2"
3 1/4" 4" 4" 3 1/4"
1"
5"X5" HSS COLUMN BEYOND
FIRST LEVEL
100' - 0"
2x12 AT 12" AND W8x13 AT COLUMN
3/4" PLYWOOD
SUBFLOOR
5/8" PRE-FINISHED
GYP. BD.
5/8" PLYWOOD
SHEATHING
CONCRETE PIER -
SEE STRUCTURAL
DRAWINGS
3x8 WD BLOCKING
1" CLEAR
FLUID APPLIED AIR
BARRIER OVER 5/8"
GLASS MAT FACED
GYPSUM SHEATHING
FIELD INSTALLED SELF
ADHERED AIR BARRIER
FLASHING MEMBRANE
SPRAY FOAM INSULATING
AIR BARRIER
R-38 BATT INSULATION
MATE LINE
MATE LINE
2 1/2" 3 1/2" 1" 3 1/2" 2 1/2"
4"
TRAILER EDGE
C L E
A R
26 ga PREFINISHED
BREAK METAL
1" CLEAR
/2
/2
/2
/2
5"X5" HSS COLUMN -
SEE STRUCT DWGS
1'-1"
2x WD
FURRING
5/8" VINYL
COATED GYP. BD.
2x4 WOOD
STUDS @ 16" O.C.
3 3/8" 5/8" 3 1/2" 1"
5/8" 5 1/2" 5/8"
BATTEN STRIP
PRE-FINISHED
CORNER GUARD -
MATCH VINYL
COATED GYP. BD.
5/8" VINYL
COATED GYP. BD.
BATTEN STRIP
PRE-FINISHED
CORNER GUARD -
MATCH VINYL
COATED GYP. BD.
/8
/8
/2
/2
/4
/8
/2
/2
/8 "5
/2
/8
11 7/8"
ROOF
122' - 3 1/8"
1"
FIELD INSTALLED SELF ADHERED
EPDM MEMBRANE AT MATE LINE
EPDM ROOF MEMBRANE
3/4" PLYWOOD
SHEATHING
3/8" GLASS MAT FACED
GYPSUM ROOF DECKING
WALL TILE - SEE
INTERIOR DRAWINGS
2x6 WD. STUDS
AT 12" O.C.
2x10 ROOF RAFTERS
R-38 BATT
INSULATION
LEAVE OPEN OF
ACCESS TO
PLUMBING
SOUND
ATTENUATED
BATT INSULATION
ROOF BEYOND
6"6"
FIELD INSTALLED 7" +/- WIDE
CONTINUOUS STRIP OF 3/8"
GLASS MAT FACED GYP BD
ROOF SHEATHING OVER FIELD
INSTALLED 3/4" PLYWOOD
FIRST LEVEL
100' - 0"
2x12 AT 12" AND W8x13 AT COLUMN
3/4" PLYWOOD
SUBFLOOR
WALL TILE - SEE
INTERIOR DRAWINGS
CONCRETE PIER -
SEE STRUCTURAL
DRAWINGS
3x8 WD BLOCKING
FLUID APPLIED AIR
BARRIER OVER 5/8"
GLASS MAT FACED
GYPSUM SHEATHING
FIELD APPLIED SPRAY
FOAM AIR BARRIER
SYSTEM
R-38 BATT
INSULATION
SECOND LEVEL
112' - 3 1/4"
3/4" PLYWOOD
SUBFLOOR
2x12 WD JOISTS AT 12" O.C. AND W8x13 AT
COLUMN
2x10 WD JOISTS AT 16" O.C. AND W8x13 AT
COLUMN
2 LAYERS 3" SOUND
ATTENUATED BATT
INSULATION
SOUND
ATTENUATED
BATT INSULATION
WALL MOUNTED
TOILET
2x6 WD. STUDS
3x8 WD.
BLOCKING
WALL TILE - SEE
INTERIOR DRAWINGS
EL
2x4 WD BLOCKING
EXPANDING FOAM
AIR BARRIER -
FIELD INSTALLED
BATT INSULATION
HSS COLUMN
/8
FLUID APPLIED AIR
BARRIER OVER 5/8"
SHEATHING
PRE-FIN. CORRUGATED
METAL SIDING AND TRIM
2x6 STUD FRAMING 24" O.C.
5/8" VINYL COATED
GYP. BD.
2x6 STUD FRAMING 24" O.C.
2x4 STUD FRAMING 24" O.C.
2x8 STUD FRAMING 24" O.C.
/8
/8
/2
/8
FIELD INSTALLED
SIDING SPLICE
/4
FIELD INSTALLED 2"
WATERTIGHT OPEN
CELL SILICONE FACED
FOAM JOINT WITH
CONTINUOUS
SEALANT BOTH SIDES
1" FOAM STRIP
METAL STRIP
METAL SIDING OVER
FLUID APPLIED AIR
BARRIER
5/8" PLYWOOD
SHEATHING
5/8" TYPE X GLASS
MAT SHEATHING
/8
/8
/2
/8
/8
/8
5/8" GYP. BD.
PREFINISHED
CORNER GUARD
6 5/8" 1" 5/8" 3 1/2"
11 3/4" US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
L O
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
P
J V
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
A-502
D E
T A
IL
S
I N
T E
R
IO
R
D B
U E
S K
IN
G
N K
E T
C H
U M
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
1 1/2" = 1'-0" A5
PLAN DETAIL AT END SHEAR WALL
1 1/2" = 1'-0" B5
PLAN DETAIL AT MATE LINE
1 1/2" = 1'-0" C3
E/W DETAIL AT ROOF RIDGE MATE LINE
1 1/2" = 1'-0" B3
E/W SHEAR WALL DETAIL AT SECOND FLOOR
1 1/2" = 1'-0" A3
E/W SHEAR WALL DETAIL AT FOUNDATION
1 1/2" = 1'-0" C5
PLAN DETAIL AT TRAILER CORNERS
1 1/2" = 1'-0" A4
PLAN DETAIL AT SHEAR WALL CORNERS
1 1/2" = 1'-0" C1
N/S DETAIL AT ROOF MATE LINE
1 1/2" = 1'-0" A1
N/S SHEAR WALL DETAIL AT FOUNDATION
1 1/2" = 1'-0" B1
N/S CHASE WALL DETAIL AT SECOND FLOOR
1 1/2" = 1'-0"
B4
COLUMN DETAIL
1 1/2" = 1'-0" C4
ELEVATOR PLAN DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
DN
UP
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-1 PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
ELEC
16261626
ELEC
16441644
SPRINKLER/
WATER
SERV.
16241624
STAIR
S1602S1602
STAIR
S1603S1603
MODULAR
ELEVATOR
E1601E1601
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RST-1
RT-1
JANITOR
16221622
BREAK
16501650
JANITOR
16481648
MOTHER'S
ROOM
16461646
COMM
16421642
COPY /
16401640
COMM
16281628
BREAK
16201620
COPY /
16301630
SIPR CAFE
16101610
LARGE
SHARED
CONFERENCE
RM
16061606
STAIR
S1601S1601
VESTIBULE
1699A1699A
ELEVATOR
LOBBY
1699C1699C
ELEV
MACHINE
ROOM
1699D1699D
OPEN
OFFICE
16721672
OPEN
OFFICE
16641664
OFFICES
1664A1664A
COPY/PRINT
1664B1664B
PRIVATE
OFFICE
1654A1654A
PRIVATE
OFFICE
1654B1654B
STORAGE
1654C1654C
OPEN
OFFICE
16541654
SEATING
16521652
CONFERENCE
16621662
SIPR CAFE
16601660
C O
R R
ID
O
R
J
J
PRIVATE
OFFICE
16661666
PRIVATE
OFFICE
16681668
OPEN
OFFICE
16701670
PRIVATE
OFFICE
16761676
PRIVATE
OFFICE
16741674
PRIVATE
OFFICE
16781678
PRIVATE
OFFICE
16801680
OPEN
OFFICE
16381638 OPEN
OFFICE
16361636
TEAMING
AREA
1636D1636D
PRIVATE
OFFICE
1636C1636C
PRIVATE
OFFICE
1636B1636B
COPY/PRINT
1636A1636A
CORRIDOR
1699H1699H
CORRIDOR
1699G1699G
PRIVATE
OFFICE
1634A1634A
PRIVATE
OFFICE
1634B1634B
PRIVATE
OFFICE
1634C1634C
TEAMING
AREA
1634D1634D
OPEN
OFFICE
16341634
OPEN
OFFICE
16321632
C O
R R
ID
O
R
F
F
SEATING
16161616
OPEN
OFFICE
16181618
CONFERENCE
16081608OPEN
OFFICE
16821682
LOBBY
1699B1699B
WAITING
16841684
SEATING
16041604
CORRIDOR
1699E1699E
TEAMING
AREA
16021602
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
MEN
16561656
WOMEN
16581658
WOMEN
16121612
MEN
16141614
CORRIDOR
1699L1699L
C O
R R
ID
O
R
K
K
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
CPT-2
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
PGB-1
RB-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
A B
IN200 B
5IN200B
D
C4
A4
C5
D
A5
IN200
SIM
B
C4
D
A4
IN200
SIM
B
C5
D
A5
CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
KEYPLAN
NORTH
16' 24'0 8'
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN101L
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
O
R
IE
N T
A T
IO
N
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
3/32" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL ONE - ORIENTATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
STAIR
S1603S1603
ELEC
16441644
MODULAR
ELEVATOR
E1601E1601
JANITOR
16481648
BREAK
16501650
COPY /
16401640
SIPR CAFE
16601660
LOBBY
1699B1699B
WAITING
16841684
OPEN
OFFICE
16361636
PRIVATE
OFFICE
1636C1636C
PRIVATE
OFFICE
1636B1636B
COPY/PRINT
1636A1636A
OPEN
OFFICE
16381638
COMM
16421642
SEATING
16521652
CONFERENCE
16621662
PRIVATE
OFFICE
16661666
PRIVATE
OFFICE
16681668
OPEN
OFFICE
16701670
PRIVATE
OFFICE
16761676
PRIVATE
OFFICE
16781678
PRIVATE
OFFICE
16801680
PRIVATE
OFFICE
16741674
OPEN
OFFICE
16541654
STORAGE
1654C1654C
PRIVATE
OFFICE
1654B1654B
PRIVATE
OFFICE
1654A1654A
OFFICES
1664A1664A
OPEN
OFFICE
16641664
COPY/PRINT
1664B1664B
CORRIDOR
1699H1699H
CORRIDOR
1699L1699L
CORRIDOR
1699J1699J
CORRIDOR
1699K1699K
TEAMING
AREA
1636D1636D
ELEV
MACHINE
ROOM
1699D1699D
ELEVATOR
LOBBY
1699C1699C
MOTHER'S
ROOM
16461646
OPEN
OFFICE
16361636
CORRIDOR
1699H1699H
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RB-1
CPT-2PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
CPT-2
CPT-2
CPT-2
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
PGB-1
RB-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
MEN
16561656
WOMEN
16581658
OPEN
OFFICE
16361636
OPEN
OFFICE
16721672
CORRIDOR
1699H1699H
PL-2
PL-4
PL-2
PL-4
PL-2
PL-4
PGB-1
RB-1
PGB-1
RB-1
A B
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN101LA
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
A
R E
A A
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
13. WHERE MULTIPLE WALL FINISHES ARE SCHEDULED, REFER TO FINISH PLANS AND
ELEVATIONS FOR APPLICATION OF WALL FINISHES.
12. PAINT MECHANICAL DIFFUSER/AIR GRILLE TO MATCH ADJACENT SURFACE.
11. PROVIDE PATCHING AND LEVELING OF FLOORING SUBSTRATE IN ALL AREAS OF
NEW FLOORING AS REQUIRED.
10. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM OUT TO PERIMETER
AND AT LEAST HALF A TILE AT EDGES.
9. GWB OPENINGS TO BE PAINTED PT-1 U.N.O.
8. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND CASED OPENINGS.
7. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS REQUIRED.
6. FLOORING MATERIAL TRANSITIONS SHALL OCCUR CENTERED UNDER DOOR WHEN
IN THE CLOSED POSITION.
5. ALL WINDOW SILLS TO RECEIVE PL-3, U.N.O.
4. ALL HOLLOW METAL DOOR FRAMES PAINTED PER DOOR SCHEDULE
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR
SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT
FOUND, NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
INTERIOR FINISH PLAN GENERAL NOTES
1/8" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL ONE - AREA A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
DNDN
UPUPUP
ELEC
16261626
STAIR
S1602S1602
SPRINKLER/
WATER
SERV.
16241624
MODULAR
ELEVATOR
E1601E1601
LOBBY
1699B1699B
WAITING
16841684
CORRIDOR
1699E1699E
CORRIDOR
1699G1699G
OPEN
OFFICE
16341634
PRIVATE
OFFICE
16761676
PRIVATE
OFFICE
16781678
PRIVATE
OFFICE
16801680
PRIVATE
OFFICE
16741674
OPEN
OFFICE
16821682
VESTIBULE
1699A1699A
ELEVATOR
LOBBY
1699C1699C
BREAK
16201620
COPY /
16301630
COMM
16281628
TEAMING
AREA
16021602
SEATING
16041604
OPEN
OFFICE
16181618
CONFERENCE
16081608
SEATING
16161616
OPEN
OFFICE
16321632
PRIVATE
OFFICE
1634C1634C
PRIVATE
OFFICE
1634B1634B
PRIVATE
OFFICE
1634A1634A
CORRIDOR
1699F1699F
JANITOR
16221622
TEAMING
AREA
1634D1634D
LARGE
SHARED
CONFERENCE
RM
16061606
STAIR
S1601S1601
SIPR CAFE
16101610
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2 WOMEN
16121612
MEN
16141614
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
A B
CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN101LB
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
A
R E
A B
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
13. WHERE MULTIPLE WALL FINISHES ARE SCHEDULED, REFER TO FINISH PLANS AND
ELEVATIONS FOR APPLICATION OF WALL FINISHES.
12. PAINT MECHANICAL DIFFUSER/AIR GRILLE TO MATCH ADJACENT SURFACE.
11. PROVIDE PATCHING AND LEVELING OF FLOORING SUBSTRATE IN ALL AREAS OF
NEW FLOORING AS REQUIRED.
10. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM OUT TO PERIMETER
AND AT LEAST HALF A TILE AT EDGES.
9. GWB OPENINGS TO BE PAINTED PT-1 U.N.O.
8. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND CASED OPENINGS.
7. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS REQUIRED.
6. FLOORING MATERIAL TRANSITIONS SHALL OCCUR CENTERED UNDER DOOR WHEN
IN THE CLOSED POSITION.
5. ALL WINDOW SILLS TO RECEIVE PL-3, U.N.O.
4. ALL HOLLOW METAL DOOR FRAMES PAINTED PER DOOR SCHEDULE
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR
SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT
FOUND, NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
INTERIOR FINISH PLAN GENERAL NOTES
1/8" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL ONE - AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
STAIR
S2603S2603
STAIR
S2601S2601
STAIR
S2602S2602
MODULAR
ELEVATOR
E2601E2601
FILE ROOM
26262626ELEC.
ROOM
26442644
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RST-1
RT-1
ELEVATOR
LOBBY
2699C2699C
CORRIDOR
2699E2699E
C O
R R
ID
O
R
F
F
CORRIDOR
2699G2699G
CORRIDOR
2699H2699H
C O
R R
ID
O
R
J
J
C O
R R
ID
O
R
K
K
CORRIDOR
2699L2699L
STAIR
LOBBY
26022602
OPEN
OFFICE
26842684 LARGE
SHARED
CONFERENCE
RM
26062606
OPEN
OFFICE
26182618
SEATING
26162616
CONFERENCE
26082608
OPEN
OFFICE
26822682PRIVATE
OFFICE
26802680
PRIVATE
OFFICE
26782678
PRIVATE
OFFICE
26762676
PRIVATE
OFFICE
26742674
TEAMING
AREA
26702670PRIVATE
OFFICE
26682668
PRIVATE
OFFICE
26662666CONFERENCE
26622662
SEATING
26522652
OPEN
OFFICE
26382638
OPEN
OFFICE
26322632
OPEN
OFFICE
26342634
OPEN
OFFICE
26362636
OPEN
OFFICE
26542654
OPEN
OFFICE
26642664
OPEN
OFFICE
26722672
PRIVATE
OFFICE
2634A2634A
PRIVATE
OFFICE
2634B2634B
PRIVATE
OFFICE
2634C2634C
COPY/
2636A2636A
PRIVATE
OFFICE
2636B2636B
PRIVATE
OFFICE
2636C2636C
TEAMING
AREA
2636D2636D
TEAMING
AREA
2634D2634D
SEATING
26042604
JANITOR
26222622
SIPR CAFE
26602660
SIPR CAFE
26102610
BREAK
26202620
COMM
26282628
COPY /
26302630
BREAK
26502650
JANITOR
26482648
COMM
26422642
COPY /
26402640
MOTHER'S
ROOM
26462646 FILE ROOM
26242624
MEN
26562656
WOMEN
26582658
WOMEN
26122612
MEN
26142614
PGB-1
RB-1
CPT-2
CPT-2
CPT-2
PGB-1
RB-1
CPT-2 PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
A B
IN200
SIM
B
4 IN200
SIM
B
C4
D
A4
C5
D
A5
IN200
SIM
B
5 IN200
SIM
B
C5
D
A5
C4
D
A4
CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
KEYPLAN
NORTH
16' 24'0 8'
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN102L
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L T
W O
O
R
IE
N T
A T
IO
N
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
3/32" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL TWO - ORIENTATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
STAIR
S2603S2603
MODULAR
ELEVATOR
E2601E2601
ELEC.
ROOM
26442644
ELEVATOR
LOBBY
2699C2699C
CORRIDOR
2699H2699H
CORRIDOR
2699J2699J
CORRIDOR
2699K2699K
CORRIDOR
2699L2699L
OPEN
OFFICE
26842684
PRIVATE
OFFICE
26802680
PRIVATE
OFFICE
26782678
PRIVATE
OFFICE
26762676
PRIVATE
OFFICE
26742674
TEAMING
AREA
26702670
PRIVATE
OFFICE
26682668
PRIVATE
OFFICE
26662666CONFERENCE
26622662
SEATING
26522652
OPEN
OFFICE
26382638
OPEN
OFFICE
26342634
OPEN
OFFICE
26362636
OPEN
OFFICE
26542654
OPEN
OFFICE
26642664
OPEN
OFFICE
26722672
COPY/
2636A2636A
PRIVATE
OFFICE
2636B2636B
PRIVATE
OFFICE
2636C2636C
TEAMING
AREA
2636D2636D
SIPR CAFE
26602660
BREAK
26502650
JANITOR
26482648
COMM
26422642
COPY /
26402640
MOTHER'S
ROOM
26462646
CORRIDOR
2699H2699H
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
WOMEN
26582658
MEN
26562656
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
CPT-2
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
A B
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN102LA
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L T
W O
A
R E
A A
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
13. WHERE MULTIPLE WALL FINISHES ARE SCHEDULED, REFER TO FINISH PLANS AND
ELEVATIONS FOR APPLICATION OF WALL FINISHES.
12. PAINT MECHANICAL DIFFUSER/AIR GRILLE TO MATCH ADJACENT SURFACE.
11. PROVIDE PATCHING AND LEVELING OF FLOORING SUBSTRATE IN ALL AREAS OF
NEW FLOORING AS REQUIRED.
10. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM OUT TO PERIMETER
AND AT LEAST HALF A TILE AT EDGES.
9. GWB OPENINGS TO BE PAINTED PT-1 U.N.O.
8. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND CASED OPENINGS.
7. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS REQUIRED.
6. FLOORING MATERIAL TRANSITIONS SHALL OCCUR CENTERED UNDER DOOR WHEN
IN THE CLOSED POSITION.
5. ALL WINDOW SILLS TO RECEIVE PL-3, U.N.O.
4. ALL HOLLOW METAL DOOR FRAMES PAINTED PER DOOR SCHEDULE
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR
SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT
FOUND, NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
INTERIOR FINISH PLAN GENERAL NOTES
1/8" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL TWO - AREA A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
DNDNDN
STAIR
S2602S2602
MODULAR
ELEVATOR
E2601E2601
STAIR
S2601S2601
FILE ROOM
26262626
ELEVATOR
LOBBY
2699C2699C
CORRIDOR
2699E2699E
CORRIDOR
2699G2699G
OPEN
OFFICE
26842684
OPEN
OFFICE
26822682
PRIVATE
OFFICE
26802680
PRIVATE
OFFICE
26782678
PRIVATE
OFFICE
26762676
PRIVATE
OFFICE
26742674
TEAMING
AREA
26702670
OPEN
OFFICE
26342634
OPEN
OFFICE
26362636
OPEN
OFFICE
26722672
CORRIDOR
2699F2699F
STAIR
LOBBY
26022602
LARGE
SHARED
CONFERENCE
RM
26062606
OPEN
OFFICE
26182618
SEATING
26162616CONFERENCE
26082608
OPEN
OFFICE
26322632
PRIVATE
OFFICE
2634A2634A
PRIVATE
OFFICE
2634B2634B
PRIVATE
OFFICE
2634C2634C
TEAMING
AREA
2634D2634D
SEATING
26042604
JANITOR
26222622SIPR CAFE
26102610
BREAK
26202620
COMM
26282628
COPY /
26302630
FILE ROOM
26242624
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
VCT-1
PGB-1
RB-1
SV-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
T-3 T-2 T-1
T-3 T-2 T-1
PGB-1
RST-1
RT-1
PGB-1
RB-1
CPT-2
WOMEN
26122612
MEN
26142614
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
PGB-1
RB-1
CPT-2
A B CARPET
(NOTE: DENSITY AND TONE OF HATCH
VARIES BASED ON SPECIFIC CARPET)
FINISH KEY
TILE
ROOM FINISH TAG
(FINISH SCHEDULE)
ROOM NAME
ROOM NUMBER
FLOOR
BASE
WALL
EXTENT OF ACCENT
WALL FINISH
XX-X
RESILIENT FLOORING
FLOORING TRANSITION
OR
REFER TO I-001 FOR MORE INFORMATION
ACT ACOUSTICAL CEILING TILE
CPT CARPET
MT METAL TRIM
PGB PREFINISHED GYPSUM BOARD
PL PLASTIC LAMINATE
PT PAINT
RB RESILIENT BASE
RST RESILIENT STAIR TREADS
RT RESILIENT TILE FLOORING
T TILE
FINISH CODE LEGEND
ACCENT
SUCH AS WP OR
CHR, THIS FIELD
LISTED ONLY WHEN
APPLICABLE
CPT-2CPT-1
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IN102LB
IN
T
E R
IO
R
F
IN
IS
H
P L A
N B
U
IL
D
IN
G O
N E
L
E V
E L T
W O
A
R E
A B
S V
A S
Q U
E Z
S V
A S
Q U
E Z
J P
A Y
N E
A
-C E
N T
R A
L A
E M
O D
13. WHERE MULTIPLE WALL FINISHES ARE SCHEDULED, REFER TO FINISH PLANS AND
ELEVATIONS FOR APPLICATION OF WALL FINISHES.
12. PAINT MECHANICAL DIFFUSER/AIR GRILLE TO MATCH ADJACENT SURFACE.
11. PROVIDE PATCHING AND LEVELING OF FLOORING SUBSTRATE IN ALL AREAS OF
NEW FLOORING AS REQUIRED.
10. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM OUT TO PERIMETER
AND AT LEAST HALF A TILE AT EDGES.
9. GWB OPENINGS TO BE PAINTED PT-1 U.N.O.
8. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND CASED OPENINGS.
7. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS REQUIRED.
6. FLOORING MATERIAL TRANSITIONS SHALL OCCUR CENTERED UNDER DOOR WHEN
IN THE CLOSED POSITION.
5. ALL WINDOW SILLS TO RECEIVE PL-3, U.N.O.
4. ALL HOLLOW METAL DOOR FRAMES PAINTED PER DOOR SCHEDULE
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR
SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT
FOUND, NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE
IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
INTERIOR FINISH PLAN GENERAL NOTES
1/8" = 1'-0" A1
INTERIOR FINISH PLAN - BUILDING ONE - LEVEL TWO - AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
6'-3"
51" H PANEL
ELECTRIC DOWN SPLINE
STORAGE TOWER WITH FILE/FILE
DRAWERS AND SIDE OPENING
STORAGE
BOX/BOX/FILE STORAGE PEDESTAL
WIRE MANAGEMENT
COAT HOOK
CPU HOLDER BELOW DESK
KEYBOARD TRAY
DUAL MONITOR ARM
6'-6"
6'-3"
4'-0"
OVERHEADS WITH TASK LIGHTING
66" H PANELS WITH ELECTRIC DOWN SPLINE
FILE/FILE DRAWERS
BOX/BOX/FILE STORAGE
4'-0"
WIRE MANAGEMENT
COAT HOOK
CPU HOLDER BELOW DESK
KEYBOARD TRAY
DUAL MONITOR ARM
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
IF200
F U
R N
IT
U
R E
T Y
P
IC
A L S
A N
D N
O T
E S
D e s ig n e r
A u th o r
C h e c k e r
A
-C E
N T
R A
L A
E M
O D
Manufacturer: Teknion Leverage (or equivalent)
A. Panels, Panel Surfaces, Panel Tile Requirements
1. Panels and/or panel tiles must be available in tackable acoustic, power and data.
2. All panels shall conform to CGSB and ANSI/BIMA standards
3. ll panels/structural frames must be load-bearing and have 2” adjustable glides
4. All panels shall have the following height options: 42” and between 66” & 68”
5. Powered thru Center Spine and available at worksurface height
6. Grade A/1 Fabric
7. Base Paint Grade. A full range of standard paint finishes should be available.
8. All cubicles keyed individually – with master keying system
B. Worksurfaces & Storage Requirements
1. HPL Laminate Work surfaces w/ matching 3mm PVC edge
2. Work surface height to be +/- 28.5” a.f.f.
3. Minimum 1” Thick
4. Return Work surfaces are to have cross-grain laminate if applicable
5. Work surfaces are to be specified with support panels, legs, cantilevers and/or storage components per the manufacturers written recommendations to maintain all warranties.
6. All under work surface storage pedestals, files and cabinets shall be painted metal. A full range of standard paint finishes should be available.
7. All file and utility drawers shall have heavy duty ball bearing suspension with full extension glides.
Provide all file drawers with hanging folder frames. Provide all utility drawers with drawer divider and a pencil tray in 1 utility drawer. All File drawers to have full height sides.
8. All drawers to be provided with ADA approved drawer pull.
9. All storage cases shall have adjustable glides for leveling. Installation is to include leveling of all components and work surfaces.
10. Base Paint Grade. A full range of standard paint finishes should be available.
11. Any freestanding storage and lateral files should include counterweights
12. Vendor is to coordinate and provide lock cores and keying to each individual department’s requirements.
C. Lateral Files & Cabinets – Teknion Filing and Storage (or equivalent)
1. Any freestanding storage and lateral files should include counterweights
2. All file and utility drawers shall have heavy duty ball bearing suspension with full extension glides.
Provide all file drawers with hanging folder frames. All File drawers to have full height sides.
3. All drawers to be provided with ADA approved drawer pull.
4. All storage cases shall have adjustable glides for leveling. Installation is to include leveling of all components and work surfaces.
5. Base Paint Grade. A full range of standard paint finishes should be available.
6. Vendor is to coordinate and provide lock cores and keying to each individual department’s requirements.
7. Each station to be individually keyed alike.
8. All overhead storage to have task lighting underneath
9. All overhead storage to have anti-slam/soft-close mechanism
D. Electrical/Data System and Components
1. Electrical system shall be a UL listed 8-wire, four (4) circuit, shared neutral or independent neutral power system capable of multiple wiring configurations and arrangements.
2. Each typical workstation is to be provided with a minimum of four duplex receptacles. A maximum of two workstations and/or a total of (8) duplex receptacles per circuit will be allowed.
3. 4 Workstations should share 1 power pole/ceiling feed
4. Each typical workstation is to have (2) blanks for data/telephone. Furniture vendor provides cutout for the data contractor to install necessary faceplates and actual connectors.
E. Workstation Accessories
1. (1) Dual monitor arm
2. (1) Keyboard tray
3. (1) CPU holder
4. (1) Coat hook
WK1/WK2 - WORKSTATIONS
WK2WK1
3/4" = 1'-0"
WK1
3/4" = 1'-0"
WK2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
W
2Q R
B0
7-
| A-502 |
| IN101L |
| IN101LA |
| IN101LB |
| IN102L |
| IN102LA |
| IN102LB |
| IF200 |
File details come from the government source that posted it. Updated .