This document provides details of an Invitation for Bid for placement of modular facilities and leasing of modular facilities to support approximately 450 personnel. The USACE Louisville District will issue IFB W912QR20B0007 for a contractor to place modular facilities for a period of 300 calendar days. Additionally, the contractor will lease the modular facilities to the government for one base year and four option years. The modular facilities will support approximately 450 personnel. Responses to the IFB are due on an unspecified date. Award of the contract is expected to occur sometime after responses are received. The document provides relevant procurement details but does not specify pricing terms or set-asides. The federal agency involved is the US Army Corps of Engineers Louisville District. No incumbent is identified.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
US Army Corps of Engineers ®
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
C T
N
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
U M
B E
R
S
C O
S
C O
B
I L
R E
N O
V A
E
B
I L
D I N
G
F
Y
J V
L O
U I S
V I L
S
T R
I C
T
M A
R K
D E
S C
R I P
T I O
N D
A T
E
N O
V E
M B
W
2Q R2
0B
L
O U
I S
V I L
L E
K
Y
Louisville District
S W
I N
G
S
P A
C E
CERTIFIED FINAL SUBMITTAL
K.
EI
SE
N
BA
TH
A.
TA
RR
O
C-
2.
DW
G
Sa ve d:
/8 /2
3:
:3
PM
Pl ot te d:
/8 /2
3:
:5
PM
M .O
SB
O
RN
E
K.
EI
SE
N
BA
TH
C-002
C I V
I L
G E
N E
R A
L
N
O T
N
S T
R U
C T
I O
N
S
E Q
U E
N C
E
1. VISIT SITE AND DETERMINE EXTENT OF DEMOLITION REQUIRED.
2. COORDINATE DEMOLITION TO ACCOMMODATE OWNER'S OPERATIONS AND MAINTAIN SITE SECURITY/SAFETY.
3. COORDINATE WITH COR DELIVERY OF SALVAGED DEMOLISHED MATERIALS TO BASE PERSONNEL.
4. LOCATE AND MARK ALL EXISTING UTILITY LINES TO BE REMOVED AND OBTAIN WRITTEN COR APPROVAL PRIOR TO
DEMOLITION.
5. REMOVE EXISTING STRUCTURES COMPLETELY BELOW BOTTOM OF PROPOSED PAVEMENT. REMOVE STRUCTURES AND
FOUNDATIONS FROM BENEATH PROPOSED BUILDINGS AND STRUCTURES. BACKFILL REMAINING STRUCTURES OR
EXCAVATIONS.
6. SAW CUT EXISTING PAVEMENT AT LIMITS OF DEMOLITION OR REMOVE TO NEAREST JOINT IF CONCRETE. REPLACE
PAVEMENT WHEN REMOVAL EXTENDS BEYOND LIMITS OF DEMOLITION AT NO ADDITIONAL COST TO GOVERNMENT.
7. REPAIR OR REPLACE DAMAGED ITEMS NOT DESIGNATED TO BE DEMOLISHED. RESTORE TO ORIGINAL CONDITION AS
DIRECTED BY COR AT NO ADDITIONAL COST TO GOVERNMENT.
1. ALL PROPOSED FINISHED CONTOURS AND SPOT ELEVATIONS ARE FINISHED ELEVATIONS. THICKNESS OF PAVEMENTS, TOPSOIL, FLOOR SLABS, ETC. ARE TO BE SUBTRACTED FROM THESE FINISHED ELEVATIONS FOR SUBGRADE ELEVATIONS.
2. THE INTENT OF THE GRADING DRAWINGS IS TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS, STRUCTURE PADS, ROADWAYS AND PAVED AREAS. FIELD VERIFY DURING CONSTRUCTION STAKING THAT POSITIVE DRAINAGE SLOPES WILL BE
MAINTAINED. MAKE MINOR MODIFICATIONS IN GRADING TO PROVIDE POSITIVE DRAINAGE SLOPES. NOTIFY CONTRACTING
OFFICER OF ANY SIGNIFICANT DISCREPANCY.
3. REMOVAL OF SEDIMENTATION CONTROL DEVICES INSTALLED AS PART OF THE GENERAL CONTRACT IS INCLUDED IN THIS
SCOPE OF WORK.
4. GRASSING OF ALL DISTURBED AREAS NOT COVERED BY PAVEMENTS OR STRUCTURES OR LANDSCAPE PLANTING BEDS IS
INCLUDED IN THE WORK.
5. ALL PLACEMENT OF FILL WILL BE OBSERVED BY QUALIFIED SOILS TECHNICIANS WORKING UNDER THE DIRECT SUPERVISION
OF THE GEOTECHNICAL ENGINEER. ANY OPERATIONS NOT PROVIDING HOMOGENEOUS COMPACTED FILL AREAS WILL BE
MODIFIED IMMEDIATELY AS DIRECTED BY THE GEOTECHNICAL ENGINEER.
1. LOCATIONS OF EXISTING UTILITIES ARE TO BE CONSIDERED APPROXIMATE. ALL UTILITIES MAY NOT BE SHOWN. INVESTIGATE
LOCATION AND DEPTH OF EXISTING UTILITIES, EXCAVATE WITH CAUTION, HAND EXCAVATION MAY BE REQUIRED, AND NOTIFY
THE COR'S REPRESENTATIVE WHEN ANY UNIDENTIFIED UTILITY IS DISCOVERED.
2. NOTIFY ILLINOIS ONE CALL SYSTEM (JULIE) AT 1-800-892-0123 OR CALL 811 A MINIMUM OF 3 DAYS PRIOR TO EXCAVATION, DRILLING, BORING, OR ANY OTHER DISTURBANCE. CONTACT BASE CE GROUP FOR BASE MARKING OF UTILITIES A MINIMUM OF
14 DAYS PRIOR TO ANY DRILLING, BORING, OR ANY OTHER DISTURBANCE.
3. VERIFY LOCATION AND ELEVATION OF ALL EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION OF NEW UTILITIES. HIRE
THE SERVICES OF A PRIVATE UNDERGROUND UTILITY LOCATION SERVICE TO IDENTIFY UTILITIES WITHIN THE LIMITS OF WORK
PRIOR TO STARTING CONSTRUCTION. VERIFY LOCATIONS AND ELEVATIONS SHOWN ON PLAN AND PROFILE DRAWINGS. NOTIFY
COR IMMEDIATELY OF ANY VARIANCE.
4. OBTAIN WRITTEN AUTHORIZATION FROM THE COR'S REPRESENTATIVE AND FROM THE UTILITY OWNERS PRIOR TO
INTERRUPTING ANY EXISTING UTILITY (IE: WATER, SEWER, GAS, ELECTRICAL, OR COMMUNICATIONS).
5. INCLUDE IN THE WORK ALL NECESSARY BENDS, COUPLINGS, OR SPECIAL FITTINGS REQUIRED TO CONNECT TO EXISTING
UTILITIES.
6. INSTALL WATER AND FIRE LINES, WITH A MINIMUM COVER OF 3'. COORDINATE ELEVATIONS WITH OTHER UTILITIES TO
MAINTAIN THIS MINIMUM COVER. PROVIDE HYDRANTS, PIV'S, AND VALVE BOXES WITH CORRECT DEPTH OF BURY WHERE LINES
ARE DEEPER THAN THE MINIMUM. LINES SHOULD HAVE LEVEL OR CONSTANTLY ASCENDING GRADES FROM THE CONNECTION
AT THE EXISTING MAIN TO THE BUILDING.
7. PROVIDE ALL THRUST RESTRAINT ITEMS (THRUST BLOCKS, MECHANICAL JOIT RESTRAINT DEVICES, TIE RODS AND CLAMPS, ETC) PER NFPA 24 AS REQUIRED FOR PERMANENT INSTALLATION AND TESTING. PROVIDE ANY TEMPORARY MATERIALS AND
EQUIPMENT REQUIRED FOR PRESSURE OR VACUUM TESTING OF UTILITIES.
8. WHERE PARALLEL, INSTALL SEWER LINES NO CLOSER THAN 10'-0" CLEAR TO WATER LINES. WHERE SEWER CROSSES WATER, MAINTAIN MINIMUM OF 18" VERTICAL CLEARANCE (SEWER BELOW WATER).
9. DO NOT START CONSTRUCTION OR PUT SEWER OR WATER LINES INTO SERVICE UNTIL AUTHORIZATION TO CONSTRUCT OR
OPERATE IS RECEIVED AND FINAL APPROVAL IS GRANTED.
10. RESTORE EXISTING GRADED, GRASSED, OR STONE SURFACED WORK AREAS TO ORIGINAL CONDITION IN ACCORDANCE WITH
LINES, GRADES, AND PROJECT SPECIFICATIONS.
11. COORDINATE AND SCHEDULE CONSTRUCTION TO MAINTAIN ACCESS TO ALL ROADWAYS, ACCESS DRIVES, BUILDING DOORS, AND SITE WORK AREAS.
1. LAND DISTURBANCE IS ANTICIPATED TO BE LESS THAN 1 ACRE. IF CONTRACTOR
ANTICIPATES LAND DISTURBANCE TO EXCEED 1 ACRE CONTRACTOR SHALL OBTAIN
LAND DISTURBANCE APPROVAL AND CONSTRUCTION STORMWATER COVERAGE
FROM ILLINOIS EPA.
2. SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH COR TO DISCUSS
EROSION CONTROL MEASURES.
3. IMPLEMENT MEANS AND METHODS TO PREVENT TRACKING OF MUD AND DEBRIS
OUTSIDE OF THE CONSTRUCTION LIMITS.
4. CLEAR AND GRUB ONLY AREAS NECESSARY TO INSTALL EROSION CONTROL DEVICES
AS INDICATED AND INSTALL EROSION CONTROL DEVICES AS INDICATED ON
DRAWINGS.
5. INSTALL SILT FENCES AND OTHER PERIMETER CONTROLS.
6. CLEAR AND GRUB REMAINING AREAS.
7. PERFORM SITE DEMOLITION.
8. PROVIDE DUST CONTROL, AS REQUIRED.
9. PERFORM GRADING.
10. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED, INSPECTED,
MAINTAINED, AND REPAIRED IN ACCORDANCE WITH THE LATEST VERSION OF THE
ILLINOIS URBAN MANUAL.
11. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISHED GRADE. PROVIDE TEMPORARY
STABILIZATION AS REQUIRED.
12. COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION
CONTROL MEASURES.
13. REMOVE TEMPORARY EROSION CONTROL DEVICES AFTER COMPLETE SITE
STABILIZATION AND APPROVAL IS RECEIVED.
CONTRACTOR HAUL ROUTES
NTS
SHILOH GATE
HOURS: 24 HOURS, 7
DAYS PER WEEK
BELLEVILLE GATE
HOURS: MON-SUN
5:30 AM - 10:00 PM
MASCOUTAH GATE
COMMERCIAL VEHICLE
INSPECTION STATION
HOURS: MON - FRI
6:00 AM - 3:00 PM
N
PROJECT SITE
1. THE MASCOUTAH GATE SHALL BE USED FOR LARGE DELIVERIES, OVERSIZED LOADS, DUMP TRUCKS AND CONCRETE TRUCKS.
NON-COMMERCIAL VEHICLES SHALL USE THE BELLEVILLE AND SHILOH GATES. CONTRACTOR SHALL COORDINATE WITH COR
FOR USE OF MASCOUTAH GATE OUTSIDE NORMAL HOURS.
2. CONTRACTOR SHALL VERIFY HAUL ROUTE FOR TRANSPORT OF OVERSIZED LOADS FROM THE MASCOUTAH GATE TO THE
PROJECT SITE.
3. CONTRACTOR SHALL COORDINATE WITH COR ON TRAFFIC CONTROL ALONG HAUL ROUTE BETWEEN THE PROJECT SITE AND
THE MASCOUTAH GATE WHEN TRANSPORTING OVERSIZED LOADS.
4. CONTRACTOR SHALL COORDINATE WITH COR FOR STAGING ANY MODULAR UNITS ON BASE OUTSIDE PROJECT LIMITS.
STATIC/RESIDUAL
HYDRANT
FLOW HYDRANT
A M
E N
D M
E N
T
A M
E N
D M
E N
T
W
2Q R
B0
7-
S D
SD
SD
SD
S D
S D
SD
SD
SD
S D
S D
S D
S D
S
D
BUILDING
BUILDING
BUILDING
WEST MARTIN STREET
W A
I V
E
W A
I V
E
ES ES ES ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
ES
E
S
E S
E S
E
S
ES
ES
ES
ES
ES
ES
ES
E S
COMM
C O
M M
C
O
M
M
C
O
M
M
G
G
G G G
ES ES
ES
ES ES
E S
E S
E S
E S
E S
E S
W W
W W
G
G
G
G
SD
SD
S D
S D
S D
S D
S D
S D
S D
S D
SD
SD
SD
SD
SD
SD
SD
S
D
S
D
S
D
COMM
COMM
C O
M M
C O
M
M
COMM
C O
M M
COMM COMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM
COMM
COMM COMM
COMM
COMM
C
O
M
M
C
O
M
M
C
O
M
M
ES
ES
ES
ES
E S
E S
E S
ES ES
E
S
E S
ES
ES
ES
ES
ES
ES
ES
ES
E S
E S
E S
ES
E S
E S
E
S
E
S
E
S
E
S
E
S
E
S
E S
E S
E S
C O
M M
COMM
COMM
C O
M M
C O
M M
C O
M M
C O
M M
COMM
COMM
C O
M M
C O
M M
W
W W
W W
W W
W W W W W W W
CB
CB
CB
CB
D
SD
S D
E E
E E
E E
E E
E E
E E
EEEEEEEEEEE
E
E E
E
E
E
E
8" X 6" WYE
6" PVC
SANITARY
LATERAL
6" PVC
SANITARY
LATERAL
CONNECT TO
MANHOLE
8' X 8'
CONC
XFMR
PAD
8' X 8'
CONC
XFMR
PAD
ELEC
DUCTBANK
6" WATER
MAIN
RELOCATE FH,
CONNECT NEW
6" WATERMAIN
TO EX VALVE.
RELOCATE FH,
CONNECT NEW 6"
WATERMAIN TO
EX WATERMAIN
W/ 90° BEND.
CURB
INLET
DOMED
INLET
DOMED
INLET
MH
6" ROOF
DRAIN @ 2%
24' - 6" ROOF
DRAIN @ 1%
8" ROOF
DRAIN @ 1%
(SEE NOTE)
FH
6" VALVE
REPLACE
SOLID LID WITH
SLOTTED LID
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I L
E
N
U M
B E
R
S
C O
S
C O
B
R E
N O
V A
B
I L
D I N
G
F
Y
L O
U I S
V I L
S
T R
I C
T
M A
R K
D E
S C
R I P
T I O
N D
A T
E
N O
V E
M B
W
2Q R2
0B
L
O U
I S
V I L
L E
K
Y
Louisville District
S W
I N
G
S
P A
C E
CERTIFIED FINAL SUBMITTAL
K.
E
IS
EN
BA
TH
A.
T
AR
RO
CU
1.
DW
G
Sa ve d:
/8 /2
3:
:4
PM
Pl ot te d:
/8 /2
3:
:1
PM
M . O
SB
O
RN
E
K.
E
IS
EN
BA
TH
CU101
C I V
I L
S I T
E
U
T I L
I T
Y
P
L A
N
0 30 60 90
1"=30'
N
NOTES:
1. SANITARY LATERALS SHALL EXTEND BENEATH
BUILDINGS AND END WITH A CLEANOUT. SEE
WATER, WASTE AND VENT PLAN SHEETS.
2. CONNECT 8" ROOF DRAIN LINE TO PLUG /
BULKHEAD OF EXISTING 12" STORM.
3. FOR INFORMATION ONLY: WATER SUPPLY
FLOW TEST CONDUCTED ON MARCH 12, 2019
AT 7:30 AM.
STATIC/RESIDUAL HYDRANT LOCATED
NEAR THE INTERSECTION OF WARD DR.
AND W BIRCHARD ST.
(SEE MAP ON SHEET C-002)
STATIC PRESSURE: 48 PSI
RESIDUAL PRESSURE: 46 PSI
FLOW HYDRANT LOCACTED SOUTH OF
B1640
FLOW 860 GPM
# - COORDINATE POINT NUMBER
KEYED NOTES
WORK ASSOCIATED WITH FUTURE CONCEPTUAL
BUILDING 2 - NOT PART OF BID PACKAGE, EXCEPT
FOR WATER LINE AND FIRE HYDRANTS.
A M
E N
D M
E N
T
A M
E N
D M
E N
T
W
2Q R
B0
7-
ROOF
122' - 3 1/8"
4"
3/8" GYPSUM-FIBER
ROOF BOARD
5/8" PLYWOOD
SHEATHING
STEEL BEAM - SEE
STRUCTURAL
5/8" PLYWOOD
ROOF DECK
PRE-FINISHED
METAL WALL
PANEL
EPDM ROOF
MEMBRANE
PRE-FINISHED
METAL ROOF
TRIM
FLUID APPLIED AIR
BARRIER
SPRAY FOAM
INSULATION
SECOND LEVEL
112' - 3 1/4"
STEEL BEAM
3/4" PLYWOOD
SUBFLOOR
2x12 WD JOISTS AT 12" O.C. AND W8x13 AT
COLUMN
SPRAY FOAM
INSULATING
AIR BARRIER
2x10 WD JOISTS AT 16" O.C. AND W8x13 AT
COLUMN
2 LAYERS 3" SOUND
ATTENUATED BATT
INSULATION
PRE-FIN. METAL
SIDING OVER
FLUID APPLIED
AIR BARRIER
STEEL BEAM
Z-FLASHING TRIM
FIELD INSTALLED
SIDING/
SHEATHING
SPLICE
2x6 SILL PLATE ON
FOAM SILL SEALER TYP.
ALL EXTERIOR WALLS
FIRST LEVEL
100' - 0"
GROUND
97' - 0"
M
IN
WIRE MESH VENTIALTION
PANELS TO BE CORROSION-
RESISTANT HOT DIPPED
GALVANIZED WIRE MESH, NOT
LESS THAN .017 INCHES THICK
WIRE, WITH LEAST DIMENSION
NOT GREATER THAN 1/8"
CONCRETE PIER -
SEE STRUCTURAL
2" x 2" x 1/8"
GALVANIZED
METAL ANGLES
METAL PANEL
SIDING W/ J TRIM
SPRAY FOAM
INSULATING AIR BARRIER
2" x 1" TERMINATION BAR
W/ SELF TAPPING
SCREWS @ 12" O.C.
2x BLOCKING -
RIP TO FIT
FLUID APPLIED AIR
BARRIER OVER 5/8"
GLASS MAT FACED
GYPSUM SHEATHING
VARIES -
FLUID APLIED AIR
BARRIER OVER 5/8"
PLYWOOD SHEATHING
2x6 SILL PLATE ON FOAM
SILL SEALER TYP. ALL
EXTERIOR WALLS
ROOF
122' - 3 1/8"
1/4" / 1'-0"
METAL SIDING
5/8" PLYWOOD
SHEATHING
2x6 WD. STUDS
AT 16" O.C.
STEEL BEAM - SEE
STRUCTURAL
EPDM ROOF MEMBRANE
5 1/4"x7" OGEE PROFILE MTL.
GUTTER AND 3 3/4"x5"
RECTANGULAR CORRUGATED
DOWNSPOUT
R-21 BATT
INSULATION W/
KRAFT FACE
COORDINATE HVAC
LOCATION WITH
MECHANICAL
2x BLOCKING -
SEE STRUCTURAL
2x6 WD. STUDS
AT 16" O.C.
COORDINATE
HVAC LOCATION
WITH MECHANICAL
2x BLOCKING -
SEE STRUCTURAL
5/8" VINYL
COVERED GYP BD.
CEILING - SEE
INTERIORS
FOR FINISH
3/8" GYPSUM-FIBER
ROOF BOARD
5/8" PLYWOOD
ROOF DECK
PREFIN. METAL
DRIP EDGE
R-38 BATT INSULATION
SPRAY FOAM INSULATION
ROOF
122' - 3 1/8"
CORUGATED METAL
PANEL SIDING W/ J TRIM
LAP ROOF MEMBRANE
UP WALL - SECURE WITH
TERMINATION BAR
RIGID INSULATION
ROOF CRICKET
FOAM
BACKER ROD
1" / 1'-0"
STEEL BEAM - SEE
STRUCTURAL
DRAWINGS
WD. BLOCKING
CONTINUOUS WD.
BLOCKING
2"
1-HOUR FIRE
RATED MODULAR
ELEVATOR SHAFT
WALL ASSEMBLY
R-38 BATT INSULATION
CURB FLASHING PER
MFR. SPECIFICATIONS
CURB ROOF MEMBRANE
SPLICE TAPE (FACTORY
LAMINATED ON ONE EDGE)
HOT DIPPED GALVANIZED
NAILS LENGTH PER MFR.
SPECIFICATIONS. 6" O.C. MAX.
NOTES:
1. CLEAN AND PRIME EPDM
MATING SURFACES PRIOR TO
INSTALLATION.
NOTES:
1. REMOVE ALL EXISTING FLASHINGS, LEAD, ETC.
PIPE SURFACE MUST BE FREE OF ALL RUST,
GREASE, INSULATION, ETC.
2. PIPE MUST BE ANCHORED TO ENSURE STABILITY.
3. CLAMPING RING AROUND FLASHING IS
UNACCEPTABLE.
4. WHEN OUTSIDE DIA. OF PIPE EXCEEDS 18",
ADDITIONAL MEMBRANE SECUREMENT REQ'D.
5. APPLY LAP SEALANT AROUND ENTIRE PERIMETER
OF FLASHING AS REQ'D FOR AIR TIGHT SEAL.
6. DO NOT USE WHEN SERVICE LINE TEMP.
EXCEEDS 180 DEG.
FLASHING PER MFR.
SPECIFICATIONS
ROOF MEMBRANE
PENETRATION
SUBSTRATE
FLASHING PER MFR.
SPECIFICATIONS
ADHESIVE
CONT. BEAD OF
LAP SEALANT
BONDING ADHESIVE
(ADHERED SYSTEM ONLY)
CONT. BEAD OF
LAP SEALANT 1/2" COVER BOARD
METAL SIDING WITH
METAL J TRIM
FLUID APPLIED AIR
BARRIER OVER 5/8"
PLYWOOD SHEATHING
2x6 WD. STUDS
R-21 BATT INSULATION
W/ KRAFT FACE
RETURN VINYL COATED
GYP. BD. TO ALUM.
FRAME
ALUM. WINDOW UNIT W/
SHIM, BACKER ROD,
AND SEALANT - FLUSH
W/ SHEATHING
WD. HEADER - SEE
STRUCTURAL - FILL
WITH BATT INSULATION
PRE-FINISHED CORNER
GUARD - MATCH VINYL
COATED GYP. BD.
PREFIN. METAL SILL
PAN FLASHING W/
DRIP EDGE
FLUID APPLIED AIR
BARRIER OVER 5/8"
PLYWOOD SHEATHING
ALUM. WINDOW UNIT W/
SHIM, BACKER ROD,
AND SEALANT - FLUSH
W/ SHEATHING
1" PLAM WINDOW SILL -
SEE INTERIOR DRAWINGS
5/8" VINYL COATED GYP.
BD.
R-21 BATT INSULATION
W/ KRAFT FACE
2X6 SILL PLATE
PRE-FINISHED METAL
PANEL SIDING
METAL SIDING W/ J TRIM
SELF ADHERED FLASHING
PRE-FINISHED SHEET
METAL FLASHING
CONT. CLEAT ANCHORED TO
TREATED WD. BLOCKING
TREATED WD. BLOCKING
ANCHORED TO CONCRETE
5 1/4" 2 3/4" 6 1/4"
5/8" TYPE X GLASS MAT
FACED GYP SHEATHING
FLUID APPLIED AIR BARRIER
3/4" PRESSURE TREATED PLYWOOD
8" CONC. ELEV. PIT WALL - SEE
STRUCT. DRAWINGS
4" METAL STUD AND TUBE STEEL
1-HOUR MODULAR ELEVATOR
SHAFT WALL ASSEMBLY
METAL SIDING WITH
METAL J TRIM
FLUID APPLIED AIR
BARRIER OVER 5/8"
PLYWOOD SHEATHING
2x6 WD. STUDS
R-21 BATT INSULATION
W/ KRAFT FACE
ALUM. WINDOW UNIT W/
SHIM, BACKER ROD,
AND SEALANT - FLUSH
W/ SHEATHING
2x4 WOOD STUDS
5/8" VINYL COATED
GYP BD
5/8" VINYL COATED
GYP BD BEYOND
CEILING AS
SCHEDULED
WD HEADER - SEE
STRUCTURAL - FILL
WITH BATT INSULATION
5/8" 3 1/2" 11 7/8" 5 1/2" 5/8"
A .F
.F
1'-10 1/8"
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
A-501
D E
T A
IL
S
E
X T
E R
IO
R
D B
U E
S K
IN
G
N K
E T
C H
U M
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
1 1/2" = 1'-0" C5
ROOF EDGE DETAIL
1" = 1'-0" B5
HORIZONTAL MATE LINE DETAIL
1" = 1'-0" A5
WALL SECTION DETAIL
1" = 1'-0" C4
GUTTER DETAIL
1 1/2" = 1'-0"
C3
ELEVATOR - ROOF DETAIL
6" = 1'-0" C1
ROOF CURB DETAIL
6" = 1'-0" B1
ROOF PENETRATION DETAIL
1 1/2" = 1'-0"
B4
ALUM WINDOW HEAD DETAIL
1 1/2" = 1'-0" A4
ALUM. WINDOW SILL DETAIL
1 1/2" = 1'-0"
A3
FLASHING AT METAL SIDING AND PIT WALL
1 1/2" = 1'-0" A2
ALUM WINDOW HEAD DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
A-601
D O
O R
S C
H E
D U
L E
S B
U
IL
D
IN
G O
N E
D B
U E
S K
IN
G
A R
U D
Y
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
DOOR AND FRAME SCHEDULE - BUILDING ONE - LEVEL ONE
IDENTIFICATION
ROOM
NUMBER ROOM NAME
IDENTIFICATION DIMENSIONS PANEL FRAME
SILL
HEIGHT
FIRE RATING
IN MINUTES STC RATING
HARDWARE
NOTESLEVEL DOOR NO.
WIDTH
H T
PANEL
COUNT TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH GROUPW1 W2
TOTAL
WIDTH
FIRST LEVEL 1606 LARGE SHARED CONFERENCE RM 1606 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1608 CONFERENCE 1608 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1610 SIPR CAFE 1610 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4
FIRST LEVEL 1612 WOMEN 1612 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
FIRST LEVEL 1614 MEN 1614 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
FIRST LEVEL 1622 JANITOR 1622 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9
FIRST LEVEL 1624 SPRINKLER/ WATER SERV. 1624A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA2
FIRST LEVEL 1624 SPRINKLER/ WATER SERV. 1624B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW8
FIRST LEVEL 1626 ELEC 1626A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 PANIC HARDWARE
FIRST LEVEL 1626 ELEC 1626B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW7 PANIC HARDWARE
FIRST LEVEL 1628 COMM 1628 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3
FIRST LEVEL 1634A PRIVATE OFFICE 1634A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1634B PRIVATE OFFICE 1634B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1634C PRIVATE OFFICE 1634C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1636B PRIVATE OFFICE 1636B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1636C PRIVATE OFFICE 1636C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1642 COMM 1642 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3
FIRST LEVEL 1644 ELEC 1644A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 PANIC HARDWARE
FIRST LEVEL 1644 ELEC 1644B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW7 PANIC HARDWARE
FIRST LEVEL 1646 MOTHER'S ROOM 1646 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW13
FIRST LEVEL 1648 JANITOR 1648 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9
FIRST LEVEL 1654A PRIVATE OFFICE 1654A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1654B PRIVATE OFFICE 1654B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1654C STORAGE 1654C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14
FIRST LEVEL 1656 MEN 1656 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
FIRST LEVEL 1658 WOMEN 1658 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
FIRST LEVEL 1660 SIPR CAFE 1660 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4
FIRST LEVEL 1662 CONFERENCE 1662 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1664A OFFICES 1664A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1666 PRIVATE OFFICE 1666 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1668 PRIVATE OFFICE 1668 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1674 PRIVATE OFFICE 1674 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1676 PRIVATE OFFICE 1676 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1678 PRIVATE OFFICE 1678 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1680 PRIVATE OFFICE 1680 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
FIRST LEVEL 1699A VESTIBULE 1699A 6' - 0" 7' - 0" 1 3/4" 2 FG ALUM PREFIN IG-2 0" 2 ALUM PREFIN 0" CA5 SELF-CLOSING
FIRST LEVEL 1699B LOBBY 1699B 6' - 0" 7' - 0" 1 3/4" 2 FG ALUM PREFIN 1/4" TEMPERED 0" 2 ALUM PREFIN 0" CA6 SELF-CLOSING
FIRST LEVEL 1699D ELEV MACHINE ROOM 1699D 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT -2'-4" CA2
FIRST LEVEL S1601 STAIR S1601 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 20 HW12 SELF-CLOSING, SMOKE SEALED
FIRST LEVEL S1602 STAIR S1602A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 SELF-CLOSING
FIRST LEVEL S1602 STAIR S1602B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING
FIRST LEVEL S1603 STAIR S1603A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 SELF-CLOSING
FIRST LEVEL S1603 STAIR S1603B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING
Grand total: 43
DOOR AND FRAME SCHEDULE - BUILDING ONE - LEVEL TWO
IDENTIFICATION
ROOM
NUMBER ROOM NAME
IDENTIFICATION DIMENSIONS PANEL FRAME
SILL
HEIGHT
FIRE RATING
IN MINUTES STC RATING
HARDWARE
NOTESLEVEL DOOR NO.
WIDTH
H T
PANEL
COUNT TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH GROUPW1 W2
TOTAL
WIDTH
SECOND LEVEL 2606 LARGE SHARED CONFERENCE RM 2606 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2608 CONFERENCE 2608 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2610 SIPR CAFE 2610 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4
SECOND LEVEL 2612 WOMEN 2612 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
SECOND LEVEL 2614 MEN 2614 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
SECOND LEVEL 2622 JANITOR 2622 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9
SECOND LEVEL 2624 FILE ROOM 2624 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14
SECOND LEVEL 2626 FILE ROOM 2626 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14
SECOND LEVEL 2628 COMM 2628 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3
SECOND LEVEL 2634A PRIVATE OFFICE 2634A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2634B PRIVATE OFFICE 2634B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2634C PRIVATE OFFICE 2634C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2636B PRIVATE OFFICE 2636B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2636C PRIVATE OFFICE 2636C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2642 COMM 2642 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3
SECOND LEVEL 2644 ELEC. ROOM 2644 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14
SECOND LEVEL 2646 MOTHER'S ROOM 2646 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW13
SECOND LEVEL 2648 JANITOR 2648 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9
SECOND LEVEL 2656 MEN 2656 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
SECOND LEVEL 2658 WOMEN 2658 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10
SECOND LEVEL 2660 SIPR CAFE 2660 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4
SECOND LEVEL 2662 CONFERENCE 2662 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2666 PRIVATE OFFICE 2666 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2668 PRIVATE OFFICE 2668 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2674 PRIVATE OFFICE 2674 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2676 PRIVATE OFFICE 2676 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2678 PRIVATE OFFICE 2678 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL 2680 PRIVATE OFFICE 2680 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11
SECOND LEVEL S2601 STAIR S2601 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 20 HW12 SELF-CLOSING, SMOKE SEALED
SECOND LEVEL S2602 STAIR S2602 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING
SECOND LEVEL S2603 STAIR S2603 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING
Grand total: 31
NOTE: ALL INTERIOR DOORS TO HAVE A 3/4" UNDERCUT
NOTE: ALL INTERIOR DOORS TO HAVE A 3/4" UNDERCUT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
LINE OF
STRUCTURE
LINE OF
STRUCTURE
SOUND
ATTENUATION
BATTS (SAB),
WHERE OCCURS
2x4 WD STUDS AT BB4X
PARTITION TYPE AND
2X8 WD STUDS AT BB8X
PARTITION TYPE
FOR PARTITION WIDTH
REFERENCE SCHEDULE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
B4 A-701
A4
5/8" VINYL COATED
GYP. BD. EACH SIDE
CONT. FIRE CAULK
LINE OF
STRUCTURE
LINE OF
STRUCTURE
SOUND
ATTENUATION
BATTS (SAB),
WHERE OCCURS
WD STUDS
FOR PARTITION WIDTH
REFERENCE SCHEDULE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
B4
A-701
A4
5/8" VINYL COATED
GYP. BD. EACH SIDE
LINE OF
STRUCTURE
LINE OF
STRUCTURE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
A4
MATE LINE
5 1/2" WD
STUDS
1"
1/2" 1/2"
5/8" VINYL
COATED GYP
BOARD
5/8" VINYL
COATED GYP
BOARD
LINE OF
STRUCTURE
LINE OF
STRUCTURE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
A4
MATE LINE
5 1/2" WD
STUDS
1"
1/2" 1/2"
5/8" VINYL
COATED GYP
BOARD
5/8" VINYL
COATED GYP
BOARD
LINE OF
STRUCTURE
LINE OF
STRUCTURE
SOUND ATTENUATION
BATTS (SAB), PER
SCHEDULE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
5/8" GWB
5 1/2" WD
STUDS
6 1/8" 1' - 4". 6 1/8"
5/8"
MOISTURE
RESISTANT
GYP. BD
5/8" MOISTURE
RESISTANT GYP. BD
WOOD DECK
5/8" VINYL
COATED GYP.
BD.
FIRE CAULK
WOOD STUDS
UNDERSIDE
OF DECK
2x JOIST WHERE
OCCURS
1. CONDITIONS INDICATED SHOW DESIGN INTENT, ESPECIALLY IN REGARD TO ACCOMMODATION OF STRUCTURAL DEFLECTION AND CONTINUITY OF INTEGRITY OF SOUND, SMOKE AND FIRE WALLS.
2. DESIGN INTENT DETAILS ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR
HEAD-OF-WALL DESIGNS AND COMPONENTS AS APPROPRIATE FOR CONDITIONS.
3. DESIGN INTENT DETAILS MAY NOT SHOW ALL CONDITIONS TO BE ENCOUNTERED ON A PROJECT. COMPLY
WITH MANUFACTURER AND UL APPROVED METHODS FOR ATYPICAL CONDITIONS.
4. SECURE TOP OF INTERIOR PARTITIONS TO SUPERSTRUCTURE IN A WAY THAT PROVIDES LATERAL STABILITY (PERPENDICULAR-TO AND IN-PLANE WITH WALL) YET ALLOWING FOR A MINIMUM OF 3/4" OF
VERTICAL DEFLECTION OF THE SUPERSTRUCTURE.
5. AT FIRE -RATED WALLS REFER TO SPECIFICATION SECTION 07 84 00 FOR ADDITIONAL
REQUIREMENTS REGARDING HEAD-OF-WALL CONDITIONS.
7. MAINTAIN ACOUSTIC RATING WHERE SOUND-CONTROL WALLS ARE INDICATED.
9. WHERE A WALL IS DESIGNATED AS BOTH A SOUND-CONTROL WALL AND A FIRE-RATED WALL, REFER TO
FIRE-RATED HEAD-OF-WALL CONDITIONS.
10. WHERE A WALL IS DESIGNATED AS A SOUND-CONTROL WALL, FILL ALL VOIDS WITH SOUND
ATTENTUATION BATTS (SAB).
11. SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB, AND SOUND-CONTROL WALLS
REQUIRE GWB ON BOTH SIDES, BE CUT TO FOLLOW UNDULATING SURFACES OF THE
SUPERSTRUCTURE. PROVIDE A CONTINUOUS BEAD OF SEALANT (AS SPECIFIED) TO
SUPERSTRUCTURE.
GENERAL NOTES:
WOOD STUDS STEEL BEAM
SLOTTED CLIP TO ALLOW
FOR 1" STRUCTURAL
DEFLICTION AT EVERY
OTHER STUD
WOOD STUD
TOP PLATE
5/8" VINYL
COVERED GYP BD
WOOD STUDS STEEL BEAM
SLOTTED CLIP TO ALLOW
FOR 1" STRUCTURAL
DEFLICTION AT EVERY
OTHER STUD
WOOD STUD
TOP PLATE
SOUND ATTENUATED
BATT INSULATION
WHERE OCCURS
FULL PERIMETER SMOKE
AND/OR ACOUSTICAL
SEALANT EA. SIDE
LINE OF
STRUCTURE
LINE OF
STRUCTURE
SOUND
ATTENUATION
BATTS (SAB),
WHERE OCCURS
2x4 WD STUDS AT BB4
PARTITION TYPE AND
2X8 WD STUDS AT BB8
PARTITION TYPE
FOR PARTITION WIDTH
REFERENCE SCHEDULE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
B4
A-701
A4
5/8" VINYL COATED
GYP. BD. EACH SIDE
FULL PERIMERTER
SMOKE AND/OR
ACOUSTICAL SEALANT
LINE OF
STRUCTURE
LINE OF
STRUCTURE
2x4 WD STUDS AT BB4
PARTITION TYPE AND
2X6 WD STUDS AT BB6
PARTITION TYPE
FOR PARTITION WIDTH
REFERENCE SCHEDULE
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
5/8" VINYL COATED
GYP. BD. EACH SIDE
2x4 KICKER
BRACING AT
24" O.C.
CEILING AS
SCHEDULED
LINE OF
STRUCTURE
LINE OF
STRUCTURE
CEILING AS
SCHEDULED
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
SEALANT BOTH SIDES.
REF SPECS FOR TYPE
A-701
A4
MATE LINE
5 1/2" WD
STUDS
1/2" 1/2"
7 1/4" 5/8" 1" 7 1/4"
5/8" VINYL COATED
GYP. BD.
5/8" VINYL
COATED
GYP. BD.
LINE OF
STRUCTURE
LINE OF
STRUCTURE
A-701
B4
A-701
A4
5/8" VINYL COATED
GYP. BD. EACH SIDE
(TYPE AA) TYPICAL PARTITION
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
AA4 3 1/2" 4 3/4" - -
AA4F 4 1/8" - -
AA6 5 1/2" 6 3/4" - -
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
A-701
S T
A N
D A
R D
P A
R T
IT
IO
N T
Y P
E S
D B
U E
S K
IN
G
N K
E T
C H
U M
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS. SOME PARTITION TYPES SHOWN ON THIS SHEET MAY NOT BE USED ON THIS
PROJECT.
2. ALL WALLS NOT DESIGNATED WITH A GRAPHIC OR TAG TO BE TYPE A. IF UNCLEAR CONTACT GOVERNMENT.
3. SOUND TRANSMISSION CLASS (STC) IS A RATING SYSTEM THAT DESCRIBES THE ABILITY OF AN ASSEMBLY TO REDUCE THE TRANSMISSION OF SOUND. CONFIGURE SOUND RATED WALL ASSEMBLIES TO ACHIEVE MINIMUM STC RATING INDICATED. STC RATINGS LISTED ARE BASED ON LABORATORY TESTING AND ARE NOT INDICATIVE OF
RESULTS IN FIELD.
4. REFER TO SECTION 07 92 00 FOR ACOUSTIC SEALANTS.
5. SOUND ATTENUATION BATTS (SAB) SHALL EXTEND CONTINUOUSLY FROM FLOOR TO STRUCTURE ABOVE.
6. PARTITIONS ARE INDICATED WITH CONVENTIONAL GYPSUM WALLBOARD U.N.O.; UPGRADE TO PREMIUM TYPES OF WALLBOARD (I.E., MOISTURE-RESISTANT, TILE-BACKER BOARD, ACOUSTICALLY ENHANCED, ETC.) BASED ON THEIR
LOCATION AND ACCORDING TO REQUIREMENTS OF SECTION 09 29 00.
7. SEALANTS INDICATED MAY BE FOR FIRE RATING, SMOKE RATING, AIR PRESSURE CONTAINMENT, ACOUSTIC RATING, VERMIN CONTROL, MOVEMENT (CRACK) CONTROL AND/OR BIOLOGICAL CONTAINMENT. SEALANT JOINTS ARE TO BE SIZED FOR EXPECTED MOVEMENT OF JOINT WITH EXPANSION/CONTRACTION CAPACITY OF SEALANT MATERIAL TO MAINTAIN THE INTEGRITY OF THE SEAL FOR THESE APPLICABLE PARAMETERS. SEE SPECIFICATION SECTION 07 92
00 FOR INTERIOR JOINT SEALANTS.
8. REFER TO SECTION 07 84 00 FOR HEAD-OF-WALL FIRESTOPPING AND SEALING OF THRU-WALL PENETRATIONS.
9. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMATIC ONLY AND DOES NOT INDICATE EXACT
CONSTRUCTION CONDITIONS OR GEOMETRY.
10. ALL DIMENSIONS ARE FROM FACE TO FACE, OR CENTERLINE TO CENTERLINE, U.N.O. REFER TO PARTITION
MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN.
11. FIRE RESISTANT AND FIRE RESISTANT SMOKE BARRIER RATINGS ARE TO CONTINUE THROUGH ALL OPENINGS IN
RATED PARTITIONS.
12. SMOKE RESISTANT, FIRE RESISTANT, AND FIRE RESISTANT SMOKE BARRIER PARTITIONS SHALL EXTEND AND
SEAL TO INSIDE FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS THROUGH SOFFITS.
13. REFER TO THE TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION.
14. THE USE OF STANDARD 5/8" GYPSUM BOARD ABOVE CEILING LINE IN CONCEALED SPACES IS ACCEPTABLE.
GENERAL PARTITION NOTES:
*NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED 2x8 WALLS: U379...
*NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED 2x4 WALLS: WP3614
(TYPE BB#X) FIRE RATED PARTITION
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
BB4X 3 1/2" 4 3/4" 40 -
BB8X 7 1/4" 8 1/2" 40 -
(TYPE CC) SHEAR WALL
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
CC 5 1/2" 11 7/8" - -
CONC1 3 5/8" 1' - 0" - -
(TYPE DD) SHEAR WALL
MARK
STUD
WIDTH
PRTN
WIDTH
SOUIND ATTENUATION CLASS (STC)
W/ SAB No SAB
DD 5 1/2" 1' - 2 1/2" - -
*NOTE: STC RATING SHOWN IS FOR CHASE WALL CONDITIONS ONLY
(TYPE EE) CHASE PARTITION
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
EE6 5 1/2" 6 1/8" 40 -
3" = 1'-0" A4
STUD PARTITIONS - FIRE RATED/SMOKE RATED PARTITIONS
3" = 1'-0" C4
STUD PART. - NON-FIRE, NON-SMOKE, NON-SOUND CONTROL
3" = 1'-0" B4
STUD PART. - SMOKE PARTITIONS AND SOUND CONTROL
(TYPE BB) SOUND/SMOKE RATED...
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
BB4 3 1/2" 4 3/4" 40 -
BB8 7 1/4" 8 1/2" 40 -
(TYPE FF) PARTITION TO B.O. CEILING
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
FF4 3 1/2" 4 3/4" - -
2'-4 1/4"
(TYPE GG) SHEAR WALL PARTITION
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
GG 7 1/4" 1' - 5 3/8" - -
NOTE: AA4F - FURRING PARTITION WITH GYP ONE SIDE ONLY
(TYPE HH) NON-RATED PARTITION
MARK
STUD
WIDTH
PRTN
WIDTH
SOUND ATTENUATION CLASS (STC)
W/ SAB NO SAB
HH4 3 1/2" 4 1/8" - -
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
TYPICAL FRAME
H E
IG
H
T
2" WIDTH 2"
MIN FROM ALL
CORNERS TO BACK
OF FRAME
CLEAR WIDTH CONTINUES
FOR
60" ON PULL SIDE OF DOOR
CLEAR WIDTH CONTINUES
FOR
48" ON PUSH SIDE OF DOOR
DIMENSIONS SHOWN MUST BE FOLLOWED AT ALL
DOORS. NOTIFY GOVERNMENT IF FIELD
CONDITIONS
CONFLICT WITH ANY CLEARANCES
2"
CLEAR
1'-6"
CLEAR
1'-0"
F
FLUSH
FG
5" 5"
FULL GLASS
IG-2 1" INSULATED TEMPERED GLASS AT EXTERIOR
1/4" TEMPERED GLASS AT INTERIOR
B1
DOOR
/4
1 3/4"
WIDTH
1 3/4"
A1
A1
/4
/4
/4
/4
3/4"
1 3/4"
2'-5"
1 3/4"
3/4"
2'-10"
A
IG-1
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND,
TYP.
HOLLOW METAL
FRAME
DOOR AS SCHEDULED
FRAME BEYOND
1/2"
VARIES
SEE PLAN 1/2"
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE &
ALL AROUND, TYP.
HOLLOW METAL FRAME
DOOR AS SCHEDULED
FRAME BEYOND
P-TYPES
SEE 1/2" TYP.
FLUID APPLIED AIR BARRIER -
WRAPPED INTO OPENING
PREFINISHED METAL
SIDING AND TRIM
/2
V
A R
IE
S
S E
E P
L A
N
/2
4" 2"
ADJACENT WALL
WHERE OCCURS
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL
FRAME
WALL - SEE PLAN
FOR TYPE
DOOR AS SCHEDULED
V A
R
IE
S
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL FRAME
WALL - SEE PLAN
FOR TYPE
DOOR AS SCHEDULED
P -T
Y P
E S
S E
E
/2
T Y
P
FLUID APPLIED AIR BARRIER -
WRAPPED INTO OPENING
METAL SIDING
FRAME ANCHOR
CONT. SEALANT BETWEEN
SIING "J" TRIM AND HM FRAME
ALUMINUM THRESHOLD
SET IN MASTIC
DOOR AS SCHEDULED
HOLLOW METAL FRAME BEYOND
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
A-710
D O
O R
W
IN
D
O W
A N
D F
R A
M E
T Y
P E
S
D B
U E
S K
IN
G
N K
E T
C H
U M
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
1/4" = 1'-0"
WRAPPED HOLLOW METAL FRAME TYPES
3/4" = 1'-0"
TYPICAL DOOR CLEARANCES
HINGED PANEL TYPES
1/4" = 1'-0"
ALUMINUM STOREFRONT FRAME TYPES
1/4" = 1'-0"
WINDOW TYPES
3" = 1'-0" B5
HM - HEAD
3" = 1'-0"
B4
HM - HEAD EXT
3" = 1'-0" A5
HM - JAMB
3" = 1'-0"
A4
HM - JAMB EXT
3" = 1'-0" A3
HM - THRESHOLD EXT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
OS
OS
OS OS
OS
OSOS
OS
OSOS
OS
OS
OS
C
C
C C
C C C
C
C
C C C
C
C
C C
C C
C
C C
C
CC C
C
C
C
C
C
C
C
C
C
C
C
C
CC
CC C
C
C
C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
DL
BL
CL
ELEC
16261626
ELEC
16441644
SPRINKLER/
WATER
SERV.
16241624
STAIR
S1602S1602STAIR
S1603S1603
MODULAR
ELEVATOR
LOBBY
1699B1699B
WAITING
16841684
TEAMING
AREA
16021602 SEATING
16041604 OPEN
OFFICE
16181618
CORRIDOR
1699E1699E
CONFERENCE
16081608
SEATING
16161616
OPEN
OFFICE
16321632
CORRIDOR
1699G1699G
PRIVATE OFFICE
1634C1634C
PRIVATE OFFICE
1634B1634B
PRIVATE OFFICE
1634A1634A
OPEN
OFFICE
16341634
OPEN
OFFICE
16361636
PRIVATE OFFICE
1636C1636C
PRIVATE OFFICE
1636B1636B
COPY/PRINT
1636A1636A
OPEN
OFFICE
16381638
SEATING
16521652
CONFERENCE
16621662
PRIVATE OFFICE
16661666
PRIVATE OFFICE
16681668
OPEN
OFFICE
16701670
PRIVATE OFFICE
16761676
PRIVATE OFFICE
16781678
PRIVATE OFFICE
16801680
PRIVATE OFFICE
16741674
OPEN
OFFICE
16821682
OPEN
OFFICE
16541654
STORAGE
1654C1654C
PRIVATE OFFICE
1654B1654B
PRIVATE OFFICE
1654A1654A
OFFICES
1664A1664A
OPEN
OFFICE
16641664
COPY/PRINT
1664B1664B
OPEN
OFFICE
16721672
CORRIDOR
1699H1699H
CORRIDOR
1699L1699L
CORRIDOR
1699J1699J
CORRIDOR
1699K1699K
CORRIDOR
1699F1699F
JANITOR
16221622
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L
EL
AL
JANITOR
16481648
BREAK
16501650
COPY / PRINT
16401640
SIPR CAFE
16601660
BREAK
16201620
COPY / PRINT
16301630
COMM
16281628
COMM
16421642
TEAMING AREA
1634D1634D
TEAMING AREA
1636D1636D
VESTIBULE
1699A1699A
ELEV
MACHINE
ROOM
1699D1699D
LARGE SHARED
CONFERENCE RM
16061606
STAIR
S1601S1601
ELEVATOR LOBBY
1699C1699C
SIPR CAFE
16101610
MOTHER'S
ROOM
16461646
MEN
16561656
WOMEN
16581658
A B
MEN
16141614
WOMEN
16121612
ACT-1 24X48
ACOUSTICAL TILE
REFLECTED CEILING PLAN LEGEND
GWB
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
SMOKE DETECTOR SPEAKER/STROBE
HVAC SUPPLY
DIFFUSER
HVAC RETURN
DIFFUSER
RADIANT HEAT
PANEL
EXIT LIGHT
HVAC EXHAUST
DIFFUSER
LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED
LINEAR FLUORESCENT LUMINAIRE, PENDANT
MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
PENDANT MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
SURFACE MOUNTED
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
S C
SPRINKLER HEAD
NIGHT LIGHT FIXTURE
OS OCCUPANCY
SENSOR
KEYPLAN
NORTH
16' 24'0 8'
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
AC101L
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
D B
U E
S K
IN
G
A R
U D
Y
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR
TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.
15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF
BAFFLE UP PT-5, SEE DETAILS.
14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.
13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL
THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.
12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.
11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND
RETURNS SPECIFIC INFORMATION.
10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT
FIXTURE SPECIFIC INFORMATION.
9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS
NOTED OR SCHEDULED OTHERWISE.
8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE
ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.
7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN
ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.
6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.
5. ALL CEILINGS TO BE ACT-1, U.N.O.
4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY
CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT
DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF
WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF
INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
REFLECTED CEILING PLAN GENERAL NOTES
3/32" = 1'-0" A1
REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - ORIENTATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
OS
OSOS
OS
OS
J
J
J
J
J
J
C
C
C C
C C C
C
C
C C
C
C
C
C C
C C
C
C C
C
C C
C
C
S
C
C
C
C
C
C
C
C
ACT-1 24X48
ACOUSTICAL TILE
REFLECTED CEILING PLAN LEGEND
GWB
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
SMOKE DETECTOR SPEAKER/STROBE
HVAC SUPPLY
DIFFUSER
HVAC RETURN
DIFFUSER
RADIANT HEAT
PANEL
EXIT LIGHT
HVAC EXHAUST
DIFFUSER
LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED
LINEAR FLUORESCENT LUMINAIRE, PENDANT
MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
PENDANT MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
SURFACE MOUNTED
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
S C
SPRINKLER HEAD
NIGHT LIGHT FIXTURE
OS OCCUPANCY
SENSOR
DL
BL
CL
A3
A-382
ELEC
16441644
STAIR
S1603S1603
MODULAR
ELEVATOR
WAITING
16841684
PRIVATE OFFICE
1636C1636C
PRIVATE OFFICE
1636B1636B
COPY/PRINT
1636A1636A
OPEN OFFICE
16381638
SEATING
16521652
CONFERENCE
16621662
PRIVATE OFFICE
16661666
PRIVATE OFFICE
16681668
OPEN OFFICE
16701670
OPEN OFFICE
16541654
STORAGE
1654C1654C
PRIVATE OFFICE
1654B1654B
PRIVATE OFFICE
1654A1654A
OFFICES
1664A1664A
OPEN OFFICE
16641664
COPY/PRINT
1664B1664B
OPEN OFFICE
16721672
CORRIDOR
1699L1699L
CORRIDOR
1699J1699J
CORRIDOR
1699K1699K
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L
EL
AL
PRIVATE OFFICE
16741674
PRIVATE OFFICE
16761676
A1
A-321
A5
A-321
JANITOR
16481648
BREAK
16501650
COPY / PRINT
16401640
SIPR CAFE
16601660
COMM
16421642
TEAMING AREA
1636D1636D
ELEV
MACHINE
ROOM
1699D1699D
MOTHER'S ROOM
16461646
GWB
7'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ELEVATOR LOBBY
1699C1699C
ACT-2' x 4' 8'-0" A.F.F.
OPEN OFFICE
16361636
CORRIDOR
1699H1699H
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
MEN
16561656
WOMEN
16581658
A B
A4
A-550
TYP
A4
A-550
A5
A-550
A5
A-550
TYP
B4
A-550
TYP
B4
A-550
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
AC101LA
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
A
R E
A A
D B
U E
S K
IN
G
A R
U D
Y
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR
TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.
15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF
BAFFLE UP PT-5, SEE DETAILS.
14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.
13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL
THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.
12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.
11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND
RETURNS SPECIFIC INFORMATION.
10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT
FIXTURE SPECIFIC INFORMATION.
9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS
NOTED OR SCHEDULED OTHERWISE.
8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE
ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.
7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN
ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.
6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.
5. ALL CEILINGS TO BE ACT-1, U.N.O.
4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY
CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT
DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF
WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF
INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
REFLECTED CEILING PLAN GENERAL NOTES
1/8" = 1'-0" A1
REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - AREA A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
OS OS
OS
OS
OS
J
J
J
C
C
C
C
C
C
C
C
C
C
C
CC
CC C
C
C
C
C C
C C
C
S
S
C
C
C
C
C
DL
BL
CL
A3
A-382
SPRINKLER/ WATER
SERV.
16241624
MODULAR
ELEVATOR
WAITING
16841684
CORRIDOR
1699E1699E
CORRIDOR
1699G1699G
OPEN OFFICE
16341634
ELEC
16261626
STAIR
S1602S1602
LOBBY
1699B1699B
TEAMING AREA
16021602
SEATING
16041604
OPEN OFFICE
16181618
CONFERENCE
16081608
SEATING
16161616
OPEN OFFICE
16321632
PRIVATE OFFICE
1634C1634C
PRIVATE OFFICE
1634B1634B
PRIVATE OFFICE
1634A1634A
PRIVATE OFFICE
16781678
PRIVATE OFFICE
16801680
OPEN OFFICE
16821682
CORRIDOR
1699F1699F
JANITOR
16221622
11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L
EL
AL
CORRIDOR
1699G1699G
VESTIBULE
1699A1699A
GWB
7'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ELEVATOR LOBBY
1699C1699C
ACT-2' x 4' 8'-0" A.F.F.
LARGE SHARED
CONFERENCE RM
16061606
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
BREAK
16201620
COPY / PRINT
16301630
COMM
16281628
TEAMING AREA
1634D1634D
STAIR
S1601S1601
SIPR CAFE
16101610
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
GWB
7'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
A B
TYP
A4
A-550
TYP
A4
A-550
B4
A-550
TYP
B4
A-550
A5
A-550
A5
A-550
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
ACT-2' x 4' 8'-0" A.F.F.
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
EXPOSED
STRUCTURE
ACT-1 24X48
ACOUSTICAL TILE
REFLECTED CEILING PLAN LEGEND
GWB
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
SMOKE DETECTOR SPEAKER/STROBE
HVAC SUPPLY
DIFFUSER
HVAC RETURN
DIFFUSER
RADIANT HEAT
PANEL
EXIT LIGHT
HVAC EXHAUST
DIFFUSER
LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED
LINEAR FLUORESCENT LUMINAIRE, PENDANT
MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
PENDANT MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
SURFACE MOUNTED
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
S C
SPRINKLER HEAD
NIGHT LIGHT FIXTURE
OS OCCUPANCY
SENSOR
KEYPLAN
NORTH
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
FOR OFFICIAL USE ONLY
FOR OFFICIAL USE ONLY
1 2 3 4 5
D
C
B
A
M D
O
IE
L
CERTIFIED FINAL SUBMITTAL
S
C O
T T
D R
S
C O
T T
A F
B
IL
M O
D S
W
IN
G S
P A
C E
F
Y
P N
N O
V E
M B
E R
S W
IN
G
S P
A C
E
W Q
R B
AC101LB
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N B
U
IL
D
IN
G O
N E
L
E V
E L O
N E
A
R E
A B
D B
U E
S K
IN
G
A R
U D
Y
D L E
G G
A N
S
A
-C E
N T
R A
L A
E M
O D
1/8" = 1'-0" A1
REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - AREA B
16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR
TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.
15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF
BAFFLE UP PT-5, SEE DETAILS.
14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.
13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL
THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.
12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.
11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND
RETURNS SPECIFIC INFORMATION.
10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT
FIXTURE SPECIFIC INFORMATION.
9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS
NOTED OR SCHEDULED OTHERWISE.
8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE
ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.
7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN
ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.
6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.
5. ALL CEILINGS TO BE ACT-1, U.N.O.
4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.
3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.
2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY
CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.
1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT
DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF
WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF
INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
REFLECTED CEILING PLAN GENERAL NOTES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
AM
EN
D M
EN
T
W
2Q R
B0
7-
OS
OS
OS OS
OS
OSOS
OS
OS
OSOS
C
C
C C
C
C
C
C
C
C C
C
C C
C C
C C
C C
C
CC C
C
C
C
S
C
C
C
C
C
C
C
C
C
CCC
C
CC C
C
C
C
C C
C C
C
C
C
C
C
C
C
C
C
C
C
C
DL
BL
CL
STAIR
S2603S2603
STAIR
S2601S2601
STAIR
S2602S2602
MODULAR
ELEVATOR
FILE ROOM
26262626
ELEC.
ROOM
26442644
CORRIDOR
2699E2699E
CORRIDOR
2699F2699F
CORRIDOR
2699G2699G
CORRIDOR
2699H2699H
CORRIDOR
2699J2699J
CORRIDOR
2699K2699K
CORRIDOR
2699L2699L
STAIR
LOBBY
26022602
OPEN
OFFICE
26842684
LARGE SHARED
CONFERENCE RM
26062606
OPEN
OFFICE
26182618
SEATING
26162616
CONFERENCE
26082608OPEN
OFFICE
26822682
PRIVATE OFFICE
26802680
PRIVATE OFFICE
26782678
PRIVATE OFFICE
26762676
PRIVATE OFFICE
26742674
TEAMING
AREA
26702670
PRIVATE OFFICE
26682668
PRIVATE OFFICE
26662666
CONFERENCE
26622662SEATING
26522652
OPEN
OFFICE
26382638
OPEN
OFFICE
26322632
OPEN
OFFICE
26342634
OPEN
OFFICE
26362636
OPEN
OFFICE
26542654
OPEN
OFFICE
26642664
OPEN
OFFICE
26722672
PRIVATE OFFICE
2634A2634A
PRIVATE OFFICE
2634B2634B
PRIVATE OFFICE
2634C2634C
COPY/ PRINT
2636A2636A
PRIVATE OFFICE
2636B2636B
PRIVATE OFFICE
2636C2636C
TEAMING
AREA
2636D2636D
TEAMING
AREA
2634D2634D
1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L
EL
AL
ELEVATOR LOBBY
2699C2699C
SEATING
26042604
JANITOR
26222622
SIPR CAFE
26602660
SIPR CAFE
26102610
BREAK
26202620
COMM
26282628
COPY / PRINT
26302630
BREAK
26502650
JANITOR
26482648
COMM
26422642
COPY / PRINT
26402640
MOTHER'S
ROOM
26462646
FILE ROOM
26242624
WOMEN
26582658
MEN
26562656
A B
ACT-1 24X48
ACOUSTICAL TILE
REFLECTED CEILING PLAN LEGEND
GWB
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
SMOKE DETECTOR SPEAKER/STROBE
HVAC SUPPLY
DIFFUSER
HVAC RETURN
DIFFUSER
RADIANT HEAT
PANEL
EXIT LIGHT
HVAC EXHAUST
DIFFUSER
LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED
LINEAR FLUORESCENT LUMINAIRE, PENDANT
MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
PENDANT MOUNTED
STRIP OR TURRET FLUORESCENT LUMINAIRE,
SURFACE MOUNTED
RECESSED OR SURFACE MOUNTED FLUORESCENT
LIGHT FIXTURE
S C
SPRINKLER HEAD
NIGHT LIGHT FIXTURE
OS OCCUPANCY
SENSOR
KEYPLAN
NORTH
16' 24'0 8'
PLAN
NORTH
LA LB
MA
MB
BUILDING 1
FUTURE
BUILDING 2
KEY PLAN
US Army Corps of Engineers ® Louisville District
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E
U
IS
V
IL
L E
D
IS
T R
IC
T
L O
U
IS
V
IL
L E
K
Y D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
This is the start of the file's text. The full file is on GovTribe.