About this file

This document provides details of an Invitation for Bid for placement of modular facilities and leasing of modular facilities to support approximately 450 personnel. The USACE Louisville District will issue IFB W912QR20B0007 for a contractor to place modular facilities for a period of 300 calendar days. Additionally, the contractor will lease the modular facilities to the government for one base year and four option years. The modular facilities will support approximately 450 personnel. Responses to the IFB are due on an unspecified date. Award of the contract is expected to occur sometime after responses are received. The document provides relevant procurement details but does not specify pricing terms or set-asides. The federal agency involved is the US Army Corps of Engineers Louisville District. No incumbent is identified.

View the file

Other files

File Type Posted
W912QR20B0007-0006.pdf PDF
W912QR20B0007-0005.pdf PDF
W912QR20B0007-0004.pdf PDF
W912QR20B0007Specs-0003.pdf PDF
W912QR20B0007Plans-0003.pdf PDF
W912QR20B0007SiteVisitRoster-0003.pdf PDF
W912QR20B0007Specs-0002.pdf PDF
W912QR20B0007-0001.pdf PDF
W912QR20B0007Plans-0000.pdf PDF
W912QR20B0007Specs_Vol3-0000.pdf PDF
W912QR20B0007Plans_Drawing_Index-0000.pdf PDF
W912QR20B0007Specs_Vol1-0000.pdf PDF
W912QR20B0007Specs_Vol2-0000.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

US Army Corps of Engineers ®

SHEET ID

U S

A

R M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

F I L

E

N

A M

E

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

S O

L I C

I T

A T

I O

N

N

O

F I L

E

N

U M

B E

R

S

C O

S

C O

B

I L

R E

N O

V A

E

B

I L

D I N

G

F

Y

J V

L O

U I S

V I L

S

T R

I C

T

M A

R K

D E

S C

R I P

T I O

N D

A T

E

N O

V E

M B

W

2Q R2

0B

L

O U

I S

V I L

L E

K

Y

Louisville District

S W

I N

G

S

P A

C E

CERTIFIED FINAL SUBMITTAL

K.

EI

SE

N

BA

TH

A.

TA

RR

O

C-

2.

DW

G

Sa ve d:

/8 /2

3:

:3

PM

Pl ot te d:

/8 /2

3:

:5

PM

M .O

SB

O

RN

E

K.

EI

SE

N

BA

TH

C-002

C I V

I L

G E

N E

R A

L

N

O T

N

S T

R U

C T

I O

N

S

E Q

U E

N C

E

1. VISIT SITE AND DETERMINE EXTENT OF DEMOLITION REQUIRED.

2. COORDINATE DEMOLITION TO ACCOMMODATE OWNER'S OPERATIONS AND MAINTAIN SITE SECURITY/SAFETY.

3. COORDINATE WITH COR DELIVERY OF SALVAGED DEMOLISHED MATERIALS TO BASE PERSONNEL.

4. LOCATE AND MARK ALL EXISTING UTILITY LINES TO BE REMOVED AND OBTAIN WRITTEN COR APPROVAL PRIOR TO

DEMOLITION.

5. REMOVE EXISTING STRUCTURES COMPLETELY BELOW BOTTOM OF PROPOSED PAVEMENT. REMOVE STRUCTURES AND

FOUNDATIONS FROM BENEATH PROPOSED BUILDINGS AND STRUCTURES. BACKFILL REMAINING STRUCTURES OR

EXCAVATIONS.

6. SAW CUT EXISTING PAVEMENT AT LIMITS OF DEMOLITION OR REMOVE TO NEAREST JOINT IF CONCRETE. REPLACE

PAVEMENT WHEN REMOVAL EXTENDS BEYOND LIMITS OF DEMOLITION AT NO ADDITIONAL COST TO GOVERNMENT.

7. REPAIR OR REPLACE DAMAGED ITEMS NOT DESIGNATED TO BE DEMOLISHED. RESTORE TO ORIGINAL CONDITION AS

DIRECTED BY COR AT NO ADDITIONAL COST TO GOVERNMENT.

1. ALL PROPOSED FINISHED CONTOURS AND SPOT ELEVATIONS ARE FINISHED ELEVATIONS. THICKNESS OF PAVEMENTS, TOPSOIL, FLOOR SLABS, ETC. ARE TO BE SUBTRACTED FROM THESE FINISHED ELEVATIONS FOR SUBGRADE ELEVATIONS.

2. THE INTENT OF THE GRADING DRAWINGS IS TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS, STRUCTURE PADS, ROADWAYS AND PAVED AREAS. FIELD VERIFY DURING CONSTRUCTION STAKING THAT POSITIVE DRAINAGE SLOPES WILL BE

MAINTAINED. MAKE MINOR MODIFICATIONS IN GRADING TO PROVIDE POSITIVE DRAINAGE SLOPES. NOTIFY CONTRACTING

OFFICER OF ANY SIGNIFICANT DISCREPANCY.

3. REMOVAL OF SEDIMENTATION CONTROL DEVICES INSTALLED AS PART OF THE GENERAL CONTRACT IS INCLUDED IN THIS

SCOPE OF WORK.

4. GRASSING OF ALL DISTURBED AREAS NOT COVERED BY PAVEMENTS OR STRUCTURES OR LANDSCAPE PLANTING BEDS IS

INCLUDED IN THE WORK.

5. ALL PLACEMENT OF FILL WILL BE OBSERVED BY QUALIFIED SOILS TECHNICIANS WORKING UNDER THE DIRECT SUPERVISION

OF THE GEOTECHNICAL ENGINEER. ANY OPERATIONS NOT PROVIDING HOMOGENEOUS COMPACTED FILL AREAS WILL BE

MODIFIED IMMEDIATELY AS DIRECTED BY THE GEOTECHNICAL ENGINEER.

1. LOCATIONS OF EXISTING UTILITIES ARE TO BE CONSIDERED APPROXIMATE. ALL UTILITIES MAY NOT BE SHOWN. INVESTIGATE

LOCATION AND DEPTH OF EXISTING UTILITIES, EXCAVATE WITH CAUTION, HAND EXCAVATION MAY BE REQUIRED, AND NOTIFY

THE COR'S REPRESENTATIVE WHEN ANY UNIDENTIFIED UTILITY IS DISCOVERED.

2. NOTIFY ILLINOIS ONE CALL SYSTEM (JULIE) AT 1-800-892-0123 OR CALL 811 A MINIMUM OF 3 DAYS PRIOR TO EXCAVATION, DRILLING, BORING, OR ANY OTHER DISTURBANCE. CONTACT BASE CE GROUP FOR BASE MARKING OF UTILITIES A MINIMUM OF

14 DAYS PRIOR TO ANY DRILLING, BORING, OR ANY OTHER DISTURBANCE.

3. VERIFY LOCATION AND ELEVATION OF ALL EXISTING UTILITIES PRIOR TO START OF CONSTRUCTION OF NEW UTILITIES. HIRE

THE SERVICES OF A PRIVATE UNDERGROUND UTILITY LOCATION SERVICE TO IDENTIFY UTILITIES WITHIN THE LIMITS OF WORK

PRIOR TO STARTING CONSTRUCTION. VERIFY LOCATIONS AND ELEVATIONS SHOWN ON PLAN AND PROFILE DRAWINGS. NOTIFY

COR IMMEDIATELY OF ANY VARIANCE.

4. OBTAIN WRITTEN AUTHORIZATION FROM THE COR'S REPRESENTATIVE AND FROM THE UTILITY OWNERS PRIOR TO

INTERRUPTING ANY EXISTING UTILITY (IE: WATER, SEWER, GAS, ELECTRICAL, OR COMMUNICATIONS).

5. INCLUDE IN THE WORK ALL NECESSARY BENDS, COUPLINGS, OR SPECIAL FITTINGS REQUIRED TO CONNECT TO EXISTING

UTILITIES.

6. INSTALL WATER AND FIRE LINES, WITH A MINIMUM COVER OF 3'. COORDINATE ELEVATIONS WITH OTHER UTILITIES TO

MAINTAIN THIS MINIMUM COVER. PROVIDE HYDRANTS, PIV'S, AND VALVE BOXES WITH CORRECT DEPTH OF BURY WHERE LINES

ARE DEEPER THAN THE MINIMUM. LINES SHOULD HAVE LEVEL OR CONSTANTLY ASCENDING GRADES FROM THE CONNECTION

AT THE EXISTING MAIN TO THE BUILDING.

7. PROVIDE ALL THRUST RESTRAINT ITEMS (THRUST BLOCKS, MECHANICAL JOIT RESTRAINT DEVICES, TIE RODS AND CLAMPS, ETC) PER NFPA 24 AS REQUIRED FOR PERMANENT INSTALLATION AND TESTING. PROVIDE ANY TEMPORARY MATERIALS AND

EQUIPMENT REQUIRED FOR PRESSURE OR VACUUM TESTING OF UTILITIES.

8. WHERE PARALLEL, INSTALL SEWER LINES NO CLOSER THAN 10'-0" CLEAR TO WATER LINES. WHERE SEWER CROSSES WATER, MAINTAIN MINIMUM OF 18" VERTICAL CLEARANCE (SEWER BELOW WATER).

9. DO NOT START CONSTRUCTION OR PUT SEWER OR WATER LINES INTO SERVICE UNTIL AUTHORIZATION TO CONSTRUCT OR

OPERATE IS RECEIVED AND FINAL APPROVAL IS GRANTED.

10. RESTORE EXISTING GRADED, GRASSED, OR STONE SURFACED WORK AREAS TO ORIGINAL CONDITION IN ACCORDANCE WITH

LINES, GRADES, AND PROJECT SPECIFICATIONS.

11. COORDINATE AND SCHEDULE CONSTRUCTION TO MAINTAIN ACCESS TO ALL ROADWAYS, ACCESS DRIVES, BUILDING DOORS, AND SITE WORK AREAS.

1. LAND DISTURBANCE IS ANTICIPATED TO BE LESS THAN 1 ACRE. IF CONTRACTOR

ANTICIPATES LAND DISTURBANCE TO EXCEED 1 ACRE CONTRACTOR SHALL OBTAIN

LAND DISTURBANCE APPROVAL AND CONSTRUCTION STORMWATER COVERAGE

FROM ILLINOIS EPA.

2. SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH COR TO DISCUSS

EROSION CONTROL MEASURES.

3. IMPLEMENT MEANS AND METHODS TO PREVENT TRACKING OF MUD AND DEBRIS

OUTSIDE OF THE CONSTRUCTION LIMITS.

4. CLEAR AND GRUB ONLY AREAS NECESSARY TO INSTALL EROSION CONTROL DEVICES

AS INDICATED AND INSTALL EROSION CONTROL DEVICES AS INDICATED ON

DRAWINGS.

5. INSTALL SILT FENCES AND OTHER PERIMETER CONTROLS.

6. CLEAR AND GRUB REMAINING AREAS.

7. PERFORM SITE DEMOLITION.

8. PROVIDE DUST CONTROL, AS REQUIRED.

9. PERFORM GRADING.

10. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED, INSPECTED,

MAINTAINED, AND REPAIRED IN ACCORDANCE WITH THE LATEST VERSION OF THE

ILLINOIS URBAN MANUAL.

11. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISHED GRADE. PROVIDE TEMPORARY

STABILIZATION AS REQUIRED.

12. COORDINATE WITH EROSION CONTROL INSPECTOR PRIOR TO REMOVAL OF EROSION

CONTROL MEASURES.

13. REMOVE TEMPORARY EROSION CONTROL DEVICES AFTER COMPLETE SITE

STABILIZATION AND APPROVAL IS RECEIVED.

CONTRACTOR HAUL ROUTES

NTS

SHILOH GATE

HOURS: 24 HOURS, 7

DAYS PER WEEK

BELLEVILLE GATE

HOURS: MON-SUN

5:30 AM - 10:00 PM

MASCOUTAH GATE

COMMERCIAL VEHICLE

INSPECTION STATION

HOURS: MON - FRI

6:00 AM - 3:00 PM

N

PROJECT SITE

1. THE MASCOUTAH GATE SHALL BE USED FOR LARGE DELIVERIES, OVERSIZED LOADS, DUMP TRUCKS AND CONCRETE TRUCKS.

NON-COMMERCIAL VEHICLES SHALL USE THE BELLEVILLE AND SHILOH GATES. CONTRACTOR SHALL COORDINATE WITH COR

FOR USE OF MASCOUTAH GATE OUTSIDE NORMAL HOURS.

2. CONTRACTOR SHALL VERIFY HAUL ROUTE FOR TRANSPORT OF OVERSIZED LOADS FROM THE MASCOUTAH GATE TO THE

PROJECT SITE.

3. CONTRACTOR SHALL COORDINATE WITH COR ON TRAFFIC CONTROL ALONG HAUL ROUTE BETWEEN THE PROJECT SITE AND

THE MASCOUTAH GATE WHEN TRANSPORTING OVERSIZED LOADS.

4. CONTRACTOR SHALL COORDINATE WITH COR FOR STAGING ANY MODULAR UNITS ON BASE OUTSIDE PROJECT LIMITS.

STATIC/RESIDUAL

HYDRANT

FLOW HYDRANT

A M

E N

D M

E N

T

A M

E N

D M

E N

T

W

2Q R

B0

7-

S D

SD

SD

SD

S D

S D

SD

SD

SD

S D

S D

S D

S D

S

D

BUILDING

BUILDING

BUILDING

WEST MARTIN STREET

W A

I V

E

W A

I V

E

ES ES ES ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

E

S

E S

E S

E

S

ES

ES

ES

ES

ES

ES

ES

E S

COMM

C O

M M

C

O

M

M

C

O

M

M

G

G

G G G

ES ES

ES

ES ES

E S

E S

E S

E S

E S

E S

W W

W W

G

G

G

G

SD

SD

S D

S D

S D

S D

S D

S D

S D

S D

SD

SD

SD

SD

SD

SD

SD

S

D

S

D

S

D

COMM

COMM

C O

M M

C O

M

M

COMM

C O

M M

COMM COMM

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

COMM COMM

COMM

COMM

C

O

M

M

C

O

M

M

C

O

M

M

ES

ES

ES

ES

E S

E S

E S

ES ES

E

S

E S

ES

ES

ES

ES

ES

ES

ES

ES

E S

E S

E S

ES

E S

E S

E

S

E

S

E

S

E

S

E

S

E

S

E S

E S

E S

C O

M M

COMM

COMM

C O

M M

C O

M M

C O

M M

C O

M M

COMM

COMM

C O

M M

C O

M M

W

W W

W W

W W

W W W W W W W

CB

CB

CB

CB

D

SD

S D

E E

E E

E E

E E

E E

E E

EEEEEEEEEEE

E

E E

E

E

E

E

8" X 6" WYE

6" PVC

SANITARY

LATERAL

6" PVC

SANITARY

LATERAL

CONNECT TO

MANHOLE

8' X 8'

CONC

XFMR

PAD

8' X 8'

CONC

XFMR

PAD

ELEC

DUCTBANK

6" WATER

MAIN

RELOCATE FH,

CONNECT NEW

6" WATERMAIN

TO EX VALVE.

RELOCATE FH,

CONNECT NEW 6"

WATERMAIN TO

EX WATERMAIN

W/ 90° BEND.

CURB

INLET

DOMED

INLET

DOMED

INLET

MH

6" ROOF

DRAIN @ 2%

24' - 6" ROOF

DRAIN @ 1%

8" ROOF

DRAIN @ 1%

(SEE NOTE)

FH

6" VALVE

REPLACE

SOLID LID WITH

SLOTTED LID

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

US Army Corps of Engineers ®

SHEET ID

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

F I L

E

N

A M

E

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

F I L

E

N

U M

B E

R

S

C O

S

C O

B

R E

N O

V A

B

I L

D I N

G

F

Y

L O

U I S

V I L

S

T R

I C

T

M A

R K

D E

S C

R I P

T I O

N D

A T

E

N O

V E

M B

W

2Q R2

0B

L

O U

I S

V I L

L E

K

Y

Louisville District

S W

I N

G

S

P A

C E

CERTIFIED FINAL SUBMITTAL

K.

E

IS

EN

BA

TH

A.

T

AR

RO

CU

1.

DW

G

Sa ve d:

/8 /2

3:

:4

PM

Pl ot te d:

/8 /2

3:

:1

PM

M . O

SB

O

RN

E

K.

E

IS

EN

BA

TH

CU101

C I V

I L

S I T

E

U

T I L

I T

Y

P

L A

N

0 30 60 90

1"=30'

N

NOTES:

1. SANITARY LATERALS SHALL EXTEND BENEATH

BUILDINGS AND END WITH A CLEANOUT. SEE

WATER, WASTE AND VENT PLAN SHEETS.

2. CONNECT 8" ROOF DRAIN LINE TO PLUG /

BULKHEAD OF EXISTING 12" STORM.

3. FOR INFORMATION ONLY: WATER SUPPLY

FLOW TEST CONDUCTED ON MARCH 12, 2019

AT 7:30 AM.

STATIC/RESIDUAL HYDRANT LOCATED

NEAR THE INTERSECTION OF WARD DR.

AND W BIRCHARD ST.

(SEE MAP ON SHEET C-002)

STATIC PRESSURE: 48 PSI

RESIDUAL PRESSURE: 46 PSI

FLOW HYDRANT LOCACTED SOUTH OF

B1640

FLOW 860 GPM

# - COORDINATE POINT NUMBER

KEYED NOTES

WORK ASSOCIATED WITH FUTURE CONCEPTUAL

BUILDING 2 - NOT PART OF BID PACKAGE, EXCEPT

FOR WATER LINE AND FIRE HYDRANTS.

A M

E N

D M

E N

T

A M

E N

D M

E N

T

W

2Q R

B0

7-

ROOF

122' - 3 1/8"

4"

3/8" GYPSUM-FIBER

ROOF BOARD

5/8" PLYWOOD

SHEATHING

STEEL BEAM - SEE

STRUCTURAL

5/8" PLYWOOD

ROOF DECK

PRE-FINISHED

METAL WALL

PANEL

EPDM ROOF

MEMBRANE

PRE-FINISHED

METAL ROOF

TRIM

FLUID APPLIED AIR

BARRIER

SPRAY FOAM

INSULATION

SECOND LEVEL

112' - 3 1/4"

STEEL BEAM

3/4" PLYWOOD

SUBFLOOR

2x12 WD JOISTS AT 12" O.C. AND W8x13 AT

COLUMN

SPRAY FOAM

INSULATING

AIR BARRIER

2x10 WD JOISTS AT 16" O.C. AND W8x13 AT

COLUMN

2 LAYERS 3" SOUND

ATTENUATED BATT

INSULATION

PRE-FIN. METAL

SIDING OVER

FLUID APPLIED

AIR BARRIER

STEEL BEAM

Z-FLASHING TRIM

FIELD INSTALLED

SIDING/

SHEATHING

SPLICE

2x6 SILL PLATE ON

FOAM SILL SEALER TYP.

ALL EXTERIOR WALLS

FIRST LEVEL

100' - 0"

GROUND

97' - 0"

M

IN

WIRE MESH VENTIALTION

PANELS TO BE CORROSION-

RESISTANT HOT DIPPED

GALVANIZED WIRE MESH, NOT

LESS THAN .017 INCHES THICK

WIRE, WITH LEAST DIMENSION

NOT GREATER THAN 1/8"

CONCRETE PIER -

SEE STRUCTURAL

2" x 2" x 1/8"

GALVANIZED

METAL ANGLES

METAL PANEL

SIDING W/ J TRIM

SPRAY FOAM

INSULATING AIR BARRIER

2" x 1" TERMINATION BAR

W/ SELF TAPPING

SCREWS @ 12" O.C.

2x BLOCKING -

RIP TO FIT

FLUID APPLIED AIR

BARRIER OVER 5/8"

GLASS MAT FACED

GYPSUM SHEATHING

VARIES -

FLUID APLIED AIR

BARRIER OVER 5/8"

PLYWOOD SHEATHING

2x6 SILL PLATE ON FOAM

SILL SEALER TYP. ALL

EXTERIOR WALLS

ROOF

122' - 3 1/8"

1/4" / 1'-0"

METAL SIDING

5/8" PLYWOOD

SHEATHING

2x6 WD. STUDS

AT 16" O.C.

STEEL BEAM - SEE

STRUCTURAL

EPDM ROOF MEMBRANE

5 1/4"x7" OGEE PROFILE MTL.

GUTTER AND 3 3/4"x5"

RECTANGULAR CORRUGATED

DOWNSPOUT

R-21 BATT

INSULATION W/

KRAFT FACE

COORDINATE HVAC

LOCATION WITH

MECHANICAL

2x BLOCKING -

SEE STRUCTURAL

2x6 WD. STUDS

AT 16" O.C.

COORDINATE

HVAC LOCATION

WITH MECHANICAL

2x BLOCKING -

SEE STRUCTURAL

5/8" VINYL

COVERED GYP BD.

CEILING - SEE

INTERIORS

FOR FINISH

3/8" GYPSUM-FIBER

ROOF BOARD

5/8" PLYWOOD

ROOF DECK

PREFIN. METAL

DRIP EDGE

R-38 BATT INSULATION

SPRAY FOAM INSULATION

ROOF

122' - 3 1/8"

CORUGATED METAL

PANEL SIDING W/ J TRIM

LAP ROOF MEMBRANE

UP WALL - SECURE WITH

TERMINATION BAR

RIGID INSULATION

ROOF CRICKET

FOAM

BACKER ROD

1" / 1'-0"

STEEL BEAM - SEE

STRUCTURAL

DRAWINGS

WD. BLOCKING

CONTINUOUS WD.

BLOCKING

2"

1-HOUR FIRE

RATED MODULAR

ELEVATOR SHAFT

WALL ASSEMBLY

R-38 BATT INSULATION

CURB FLASHING PER

MFR. SPECIFICATIONS

CURB ROOF MEMBRANE

SPLICE TAPE (FACTORY

LAMINATED ON ONE EDGE)

HOT DIPPED GALVANIZED

NAILS LENGTH PER MFR.

SPECIFICATIONS. 6" O.C. MAX.

NOTES:

1. CLEAN AND PRIME EPDM

MATING SURFACES PRIOR TO

INSTALLATION.

NOTES:

1. REMOVE ALL EXISTING FLASHINGS, LEAD, ETC.

PIPE SURFACE MUST BE FREE OF ALL RUST,

GREASE, INSULATION, ETC.

2. PIPE MUST BE ANCHORED TO ENSURE STABILITY.

3. CLAMPING RING AROUND FLASHING IS

UNACCEPTABLE.

4. WHEN OUTSIDE DIA. OF PIPE EXCEEDS 18",

ADDITIONAL MEMBRANE SECUREMENT REQ'D.

5. APPLY LAP SEALANT AROUND ENTIRE PERIMETER

OF FLASHING AS REQ'D FOR AIR TIGHT SEAL.

6. DO NOT USE WHEN SERVICE LINE TEMP.

EXCEEDS 180 DEG.

FLASHING PER MFR.

SPECIFICATIONS

ROOF MEMBRANE

PENETRATION

SUBSTRATE

FLASHING PER MFR.

SPECIFICATIONS

ADHESIVE

CONT. BEAD OF

LAP SEALANT

BONDING ADHESIVE

(ADHERED SYSTEM ONLY)

CONT. BEAD OF

LAP SEALANT 1/2" COVER BOARD

METAL SIDING WITH

METAL J TRIM

FLUID APPLIED AIR

BARRIER OVER 5/8"

PLYWOOD SHEATHING

2x6 WD. STUDS

R-21 BATT INSULATION

W/ KRAFT FACE

RETURN VINYL COATED

GYP. BD. TO ALUM.

FRAME

ALUM. WINDOW UNIT W/

SHIM, BACKER ROD,

AND SEALANT - FLUSH

W/ SHEATHING

WD. HEADER - SEE

STRUCTURAL - FILL

WITH BATT INSULATION

PRE-FINISHED CORNER

GUARD - MATCH VINYL

COATED GYP. BD.

PREFIN. METAL SILL

PAN FLASHING W/

DRIP EDGE

FLUID APPLIED AIR

BARRIER OVER 5/8"

PLYWOOD SHEATHING

ALUM. WINDOW UNIT W/

SHIM, BACKER ROD,

AND SEALANT - FLUSH

W/ SHEATHING

1" PLAM WINDOW SILL -

SEE INTERIOR DRAWINGS

5/8" VINYL COATED GYP.

BD.

R-21 BATT INSULATION

W/ KRAFT FACE

2X6 SILL PLATE

PRE-FINISHED METAL

PANEL SIDING

METAL SIDING W/ J TRIM

SELF ADHERED FLASHING

PRE-FINISHED SHEET

METAL FLASHING

CONT. CLEAT ANCHORED TO

TREATED WD. BLOCKING

TREATED WD. BLOCKING

ANCHORED TO CONCRETE

5 1/4" 2 3/4" 6 1/4"

5/8" TYPE X GLASS MAT

FACED GYP SHEATHING

FLUID APPLIED AIR BARRIER

3/4" PRESSURE TREATED PLYWOOD

8" CONC. ELEV. PIT WALL - SEE

STRUCT. DRAWINGS

4" METAL STUD AND TUBE STEEL

1-HOUR MODULAR ELEVATOR

SHAFT WALL ASSEMBLY

METAL SIDING WITH

METAL J TRIM

FLUID APPLIED AIR

BARRIER OVER 5/8"

PLYWOOD SHEATHING

2x6 WD. STUDS

R-21 BATT INSULATION

W/ KRAFT FACE

ALUM. WINDOW UNIT W/

SHIM, BACKER ROD,

AND SEALANT - FLUSH

W/ SHEATHING

2x4 WOOD STUDS

5/8" VINYL COATED

GYP BD

5/8" VINYL COATED

GYP BD BEYOND

CEILING AS

SCHEDULED

WD HEADER - SEE

STRUCTURAL - FILL

WITH BATT INSULATION

5/8" 3 1/2" 11 7/8" 5 1/2" 5/8"

A .F

.F

1'-10 1/8"

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

A-501

D E

T A

IL

S

E

X T

E R

IO

R

D B

U E

S K

IN

G

N K

E T

C H

U M

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

1 1/2" = 1'-0" C5

ROOF EDGE DETAIL

1" = 1'-0" B5

HORIZONTAL MATE LINE DETAIL

1" = 1'-0" A5

WALL SECTION DETAIL

1" = 1'-0" C4

GUTTER DETAIL

1 1/2" = 1'-0"

C3

ELEVATOR - ROOF DETAIL

6" = 1'-0" C1

ROOF CURB DETAIL

6" = 1'-0" B1

ROOF PENETRATION DETAIL

1 1/2" = 1'-0"

B4

ALUM WINDOW HEAD DETAIL

1 1/2" = 1'-0" A4

ALUM. WINDOW SILL DETAIL

1 1/2" = 1'-0"

A3

FLASHING AT METAL SIDING AND PIT WALL

1 1/2" = 1'-0" A2

ALUM WINDOW HEAD DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

A-601

D O

O R

S C

H E

D U

L E

S B

U

IL

D

IN

G O

N E

D B

U E

S K

IN

G

A R

U D

Y

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

DOOR AND FRAME SCHEDULE - BUILDING ONE - LEVEL ONE

IDENTIFICATION

ROOM

NUMBER ROOM NAME

IDENTIFICATION DIMENSIONS PANEL FRAME

SILL

HEIGHT

FIRE RATING

IN MINUTES STC RATING

HARDWARE

NOTESLEVEL DOOR NO.

WIDTH

H T

PANEL

COUNT TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH GROUPW1 W2

TOTAL

WIDTH

FIRST LEVEL 1606 LARGE SHARED CONFERENCE RM 1606 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1608 CONFERENCE 1608 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1610 SIPR CAFE 1610 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4

FIRST LEVEL 1612 WOMEN 1612 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

FIRST LEVEL 1614 MEN 1614 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

FIRST LEVEL 1622 JANITOR 1622 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9

FIRST LEVEL 1624 SPRINKLER/ WATER SERV. 1624A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA2

FIRST LEVEL 1624 SPRINKLER/ WATER SERV. 1624B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW8

FIRST LEVEL 1626 ELEC 1626A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 PANIC HARDWARE

FIRST LEVEL 1626 ELEC 1626B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW7 PANIC HARDWARE

FIRST LEVEL 1628 COMM 1628 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3

FIRST LEVEL 1634A PRIVATE OFFICE 1634A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1634B PRIVATE OFFICE 1634B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1634C PRIVATE OFFICE 1634C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1636B PRIVATE OFFICE 1636B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1636C PRIVATE OFFICE 1636C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1642 COMM 1642 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3

FIRST LEVEL 1644 ELEC 1644A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 PANIC HARDWARE

FIRST LEVEL 1644 ELEC 1644B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW7 PANIC HARDWARE

FIRST LEVEL 1646 MOTHER'S ROOM 1646 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW13

FIRST LEVEL 1648 JANITOR 1648 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9

FIRST LEVEL 1654A PRIVATE OFFICE 1654A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1654B PRIVATE OFFICE 1654B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1654C STORAGE 1654C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14

FIRST LEVEL 1656 MEN 1656 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

FIRST LEVEL 1658 WOMEN 1658 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

FIRST LEVEL 1660 SIPR CAFE 1660 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4

FIRST LEVEL 1662 CONFERENCE 1662 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1664A OFFICES 1664A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1666 PRIVATE OFFICE 1666 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1668 PRIVATE OFFICE 1668 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1674 PRIVATE OFFICE 1674 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1676 PRIVATE OFFICE 1676 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1678 PRIVATE OFFICE 1678 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1680 PRIVATE OFFICE 1680 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

FIRST LEVEL 1699A VESTIBULE 1699A 6' - 0" 7' - 0" 1 3/4" 2 FG ALUM PREFIN IG-2 0" 2 ALUM PREFIN 0" CA5 SELF-CLOSING

FIRST LEVEL 1699B LOBBY 1699B 6' - 0" 7' - 0" 1 3/4" 2 FG ALUM PREFIN 1/4" TEMPERED 0" 2 ALUM PREFIN 0" CA6 SELF-CLOSING

FIRST LEVEL 1699D ELEV MACHINE ROOM 1699D 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT -2'-4" CA2

FIRST LEVEL S1601 STAIR S1601 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 20 HW12 SELF-CLOSING, SMOKE SEALED

FIRST LEVEL S1602 STAIR S1602A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 SELF-CLOSING

FIRST LEVEL S1602 STAIR S1602B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING

FIRST LEVEL S1603 STAIR S1603A 3' - 0" 7' - 0" 1 3/4" 1 F HMI PNT --- 3/8" 1 HM PNT 0" CA1 SELF-CLOSING

FIRST LEVEL S1603 STAIR S1603B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING

Grand total: 43

DOOR AND FRAME SCHEDULE - BUILDING ONE - LEVEL TWO

IDENTIFICATION

ROOM

NUMBER ROOM NAME

IDENTIFICATION DIMENSIONS PANEL FRAME

SILL

HEIGHT

FIRE RATING

IN MINUTES STC RATING

HARDWARE

NOTESLEVEL DOOR NO.

WIDTH

H T

PANEL

COUNT TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH GROUPW1 W2

TOTAL

WIDTH

SECOND LEVEL 2606 LARGE SHARED CONFERENCE RM 2606 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2608 CONFERENCE 2608 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2610 SIPR CAFE 2610 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4

SECOND LEVEL 2612 WOMEN 2612 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

SECOND LEVEL 2614 MEN 2614 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

SECOND LEVEL 2622 JANITOR 2622 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9

SECOND LEVEL 2624 FILE ROOM 2624 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14

SECOND LEVEL 2626 FILE ROOM 2626 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14

SECOND LEVEL 2628 COMM 2628 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3

SECOND LEVEL 2634A PRIVATE OFFICE 2634A 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2634B PRIVATE OFFICE 2634B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2634C PRIVATE OFFICE 2634C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2636B PRIVATE OFFICE 2636B 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2636C PRIVATE OFFICE 2636C 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2642 COMM 2642 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA3

SECOND LEVEL 2644 ELEC. ROOM 2644 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW14

SECOND LEVEL 2646 MOTHER'S ROOM 2646 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW13

SECOND LEVEL 2648 JANITOR 2648 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW9

SECOND LEVEL 2656 MEN 2656 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

SECOND LEVEL 2658 WOMEN 2658 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW10

SECOND LEVEL 2660 SIPR CAFE 2660 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" CA4

SECOND LEVEL 2662 CONFERENCE 2662 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2666 PRIVATE OFFICE 2666 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2668 PRIVATE OFFICE 2668 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2674 PRIVATE OFFICE 2674 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2676 PRIVATE OFFICE 2676 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2678 PRIVATE OFFICE 2678 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL 2680 PRIVATE OFFICE 2680 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" HW11

SECOND LEVEL S2601 STAIR S2601 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 20 HW12 SELF-CLOSING, SMOKE SEALED

SECOND LEVEL S2602 STAIR S2602 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING

SECOND LEVEL S2603 STAIR S2603 3' - 0" 7' - 0" 1 3/4" 1 F HM PNT --- 3/8" 1 HM PNT 0" 45 HW12 SELF-CLOSING

Grand total: 31

NOTE: ALL INTERIOR DOORS TO HAVE A 3/4" UNDERCUT

NOTE: ALL INTERIOR DOORS TO HAVE A 3/4" UNDERCUT

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

LINE OF

STRUCTURE

LINE OF

STRUCTURE

SOUND

ATTENUATION

BATTS (SAB),

WHERE OCCURS

2x4 WD STUDS AT BB4X

PARTITION TYPE AND

2X8 WD STUDS AT BB8X

PARTITION TYPE

FOR PARTITION WIDTH

REFERENCE SCHEDULE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

B4 A-701

A4

5/8" VINYL COATED

GYP. BD. EACH SIDE

CONT. FIRE CAULK

LINE OF

STRUCTURE

LINE OF

STRUCTURE

SOUND

ATTENUATION

BATTS (SAB),

WHERE OCCURS

WD STUDS

FOR PARTITION WIDTH

REFERENCE SCHEDULE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

B4

A-701

A4

5/8" VINYL COATED

GYP. BD. EACH SIDE

LINE OF

STRUCTURE

LINE OF

STRUCTURE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

A4

MATE LINE

5 1/2" WD

STUDS

1"

1/2" 1/2"

5/8" VINYL

COATED GYP

BOARD

5/8" VINYL

COATED GYP

BOARD

LINE OF

STRUCTURE

LINE OF

STRUCTURE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

A4

MATE LINE

5 1/2" WD

STUDS

1"

1/2" 1/2"

5/8" VINYL

COATED GYP

BOARD

5/8" VINYL

COATED GYP

BOARD

LINE OF

STRUCTURE

LINE OF

STRUCTURE

SOUND ATTENUATION

BATTS (SAB), PER

SCHEDULE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

5/8" GWB

5 1/2" WD

STUDS

6 1/8" 1' - 4". 6 1/8"

5/8"

MOISTURE

RESISTANT

GYP. BD

5/8" MOISTURE

RESISTANT GYP. BD

WOOD DECK

5/8" VINYL

COATED GYP.

BD.

FIRE CAULK

WOOD STUDS

UNDERSIDE

OF DECK

2x JOIST WHERE

OCCURS

1. CONDITIONS INDICATED SHOW DESIGN INTENT, ESPECIALLY IN REGARD TO ACCOMMODATION OF STRUCTURAL DEFLECTION AND CONTINUITY OF INTEGRITY OF SOUND, SMOKE AND FIRE WALLS.

2. DESIGN INTENT DETAILS ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR

HEAD-OF-WALL DESIGNS AND COMPONENTS AS APPROPRIATE FOR CONDITIONS.

3. DESIGN INTENT DETAILS MAY NOT SHOW ALL CONDITIONS TO BE ENCOUNTERED ON A PROJECT. COMPLY

WITH MANUFACTURER AND UL APPROVED METHODS FOR ATYPICAL CONDITIONS.

4. SECURE TOP OF INTERIOR PARTITIONS TO SUPERSTRUCTURE IN A WAY THAT PROVIDES LATERAL STABILITY (PERPENDICULAR-TO AND IN-PLANE WITH WALL) YET ALLOWING FOR A MINIMUM OF 3/4" OF

VERTICAL DEFLECTION OF THE SUPERSTRUCTURE.

5. AT FIRE -RATED WALLS REFER TO SPECIFICATION SECTION 07 84 00 FOR ADDITIONAL

REQUIREMENTS REGARDING HEAD-OF-WALL CONDITIONS.

7. MAINTAIN ACOUSTIC RATING WHERE SOUND-CONTROL WALLS ARE INDICATED.

9. WHERE A WALL IS DESIGNATED AS BOTH A SOUND-CONTROL WALL AND A FIRE-RATED WALL, REFER TO

FIRE-RATED HEAD-OF-WALL CONDITIONS.

10. WHERE A WALL IS DESIGNATED AS A SOUND-CONTROL WALL, FILL ALL VOIDS WITH SOUND

ATTENTUATION BATTS (SAB).

11. SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB, AND SOUND-CONTROL WALLS

REQUIRE GWB ON BOTH SIDES, BE CUT TO FOLLOW UNDULATING SURFACES OF THE

SUPERSTRUCTURE. PROVIDE A CONTINUOUS BEAD OF SEALANT (AS SPECIFIED) TO

SUPERSTRUCTURE.

GENERAL NOTES:

WOOD STUDS STEEL BEAM

SLOTTED CLIP TO ALLOW

FOR 1" STRUCTURAL

DEFLICTION AT EVERY

OTHER STUD

WOOD STUD

TOP PLATE

5/8" VINYL

COVERED GYP BD

WOOD STUDS STEEL BEAM

SLOTTED CLIP TO ALLOW

FOR 1" STRUCTURAL

DEFLICTION AT EVERY

OTHER STUD

WOOD STUD

TOP PLATE

SOUND ATTENUATED

BATT INSULATION

WHERE OCCURS

FULL PERIMETER SMOKE

AND/OR ACOUSTICAL

SEALANT EA. SIDE

LINE OF

STRUCTURE

LINE OF

STRUCTURE

SOUND

ATTENUATION

BATTS (SAB),

WHERE OCCURS

2x4 WD STUDS AT BB4

PARTITION TYPE AND

2X8 WD STUDS AT BB8

PARTITION TYPE

FOR PARTITION WIDTH

REFERENCE SCHEDULE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

B4

A-701

A4

5/8" VINYL COATED

GYP. BD. EACH SIDE

FULL PERIMERTER

SMOKE AND/OR

ACOUSTICAL SEALANT

LINE OF

STRUCTURE

LINE OF

STRUCTURE

2x4 WD STUDS AT BB4

PARTITION TYPE AND

2X6 WD STUDS AT BB6

PARTITION TYPE

FOR PARTITION WIDTH

REFERENCE SCHEDULE

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

5/8" VINYL COATED

GYP. BD. EACH SIDE

2x4 KICKER

BRACING AT

24" O.C.

CEILING AS

SCHEDULED

LINE OF

STRUCTURE

LINE OF

STRUCTURE

CEILING AS

SCHEDULED

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

SEALANT BOTH SIDES.

REF SPECS FOR TYPE

A-701

A4

MATE LINE

5 1/2" WD

STUDS

1/2" 1/2"

7 1/4" 5/8" 1" 7 1/4"

5/8" VINYL COATED

GYP. BD.

5/8" VINYL

COATED

GYP. BD.

LINE OF

STRUCTURE

LINE OF

STRUCTURE

A-701

B4

A-701

A4

5/8" VINYL COATED

GYP. BD. EACH SIDE

(TYPE AA) TYPICAL PARTITION

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

AA4 3 1/2" 4 3/4" - -

AA4F 4 1/8" - -

AA6 5 1/2" 6 3/4" - -

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

A-701

S T

A N

D A

R D

P A

R T

IT

IO

N T

Y P

E S

D B

U E

S K

IN

G

N K

E T

C H

U M

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

1. PARTITIONS ARE DISTINGUISHED ON FLOOR PLANS BY SYMBOL DESIGNATION, GRAPHIC DESIGNATION OR A COMBINATION OF BOTH DESIGNATIONS. SOME PARTITION TYPES SHOWN ON THIS SHEET MAY NOT BE USED ON THIS

PROJECT.

2. ALL WALLS NOT DESIGNATED WITH A GRAPHIC OR TAG TO BE TYPE A. IF UNCLEAR CONTACT GOVERNMENT.

3. SOUND TRANSMISSION CLASS (STC) IS A RATING SYSTEM THAT DESCRIBES THE ABILITY OF AN ASSEMBLY TO REDUCE THE TRANSMISSION OF SOUND. CONFIGURE SOUND RATED WALL ASSEMBLIES TO ACHIEVE MINIMUM STC RATING INDICATED. STC RATINGS LISTED ARE BASED ON LABORATORY TESTING AND ARE NOT INDICATIVE OF

RESULTS IN FIELD.

4. REFER TO SECTION 07 92 00 FOR ACOUSTIC SEALANTS.

5. SOUND ATTENUATION BATTS (SAB) SHALL EXTEND CONTINUOUSLY FROM FLOOR TO STRUCTURE ABOVE.

6. PARTITIONS ARE INDICATED WITH CONVENTIONAL GYPSUM WALLBOARD U.N.O.; UPGRADE TO PREMIUM TYPES OF WALLBOARD (I.E., MOISTURE-RESISTANT, TILE-BACKER BOARD, ACOUSTICALLY ENHANCED, ETC.) BASED ON THEIR

LOCATION AND ACCORDING TO REQUIREMENTS OF SECTION 09 29 00.

7. SEALANTS INDICATED MAY BE FOR FIRE RATING, SMOKE RATING, AIR PRESSURE CONTAINMENT, ACOUSTIC RATING, VERMIN CONTROL, MOVEMENT (CRACK) CONTROL AND/OR BIOLOGICAL CONTAINMENT. SEALANT JOINTS ARE TO BE SIZED FOR EXPECTED MOVEMENT OF JOINT WITH EXPANSION/CONTRACTION CAPACITY OF SEALANT MATERIAL TO MAINTAIN THE INTEGRITY OF THE SEAL FOR THESE APPLICABLE PARAMETERS. SEE SPECIFICATION SECTION 07 92

00 FOR INTERIOR JOINT SEALANTS.

8. REFER TO SECTION 07 84 00 FOR HEAD-OF-WALL FIRESTOPPING AND SEALING OF THRU-WALL PENETRATIONS.

9. "LINE OF STRUCTURE" INDICATED FOR EACH PARTITION IS DIAGRAMATIC ONLY AND DOES NOT INDICATE EXACT

CONSTRUCTION CONDITIONS OR GEOMETRY.

10. ALL DIMENSIONS ARE FROM FACE TO FACE, OR CENTERLINE TO CENTERLINE, U.N.O. REFER TO PARTITION

MATRICES FOR PARTITION WIDTH DIMENSIONS UNLESS INDICATED TO BE SHOWN ON PLAN.

11. FIRE RESISTANT AND FIRE RESISTANT SMOKE BARRIER RATINGS ARE TO CONTINUE THROUGH ALL OPENINGS IN

RATED PARTITIONS.

12. SMOKE RESISTANT, FIRE RESISTANT, AND FIRE RESISTANT SMOKE BARRIER PARTITIONS SHALL EXTEND AND

SEAL TO INSIDE FACE OF EXTERIOR SHEATHING, INCLUDING EXTENSIONS THROUGH SOFFITS.

13. REFER TO THE TOILET ACCESSORIES SHEET AND CASEWORK SHEET FOR MOUNTING DETAIL INFORMATION.

14. THE USE OF STANDARD 5/8" GYPSUM BOARD ABOVE CEILING LINE IN CONCEALED SPACES IS ACCEPTABLE.

GENERAL PARTITION NOTES:

*NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED 2x8 WALLS: U379...

*NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED 2x4 WALLS: WP3614

(TYPE BB#X) FIRE RATED PARTITION

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

BB4X 3 1/2" 4 3/4" 40 -

BB8X 7 1/4" 8 1/2" 40 -

(TYPE CC) SHEAR WALL

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

CC 5 1/2" 11 7/8" - -

CONC1 3 5/8" 1' - 0" - -

(TYPE DD) SHEAR WALL

MARK

STUD

WIDTH

PRTN

WIDTH

SOUIND ATTENUATION CLASS (STC)

W/ SAB No SAB

DD 5 1/2" 1' - 2 1/2" - -

*NOTE: STC RATING SHOWN IS FOR CHASE WALL CONDITIONS ONLY

(TYPE EE) CHASE PARTITION

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

EE6 5 1/2" 6 1/8" 40 -

3" = 1'-0" A4

STUD PARTITIONS - FIRE RATED/SMOKE RATED PARTITIONS

3" = 1'-0" C4

STUD PART. - NON-FIRE, NON-SMOKE, NON-SOUND CONTROL

3" = 1'-0" B4

STUD PART. - SMOKE PARTITIONS AND SOUND CONTROL

(TYPE BB) SOUND/SMOKE RATED...

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

BB4 3 1/2" 4 3/4" 40 -

BB8 7 1/4" 8 1/2" 40 -

(TYPE FF) PARTITION TO B.O. CEILING

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

FF4 3 1/2" 4 3/4" - -

2'-4 1/4"

(TYPE GG) SHEAR WALL PARTITION

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

GG 7 1/4" 1' - 5 3/8" - -

NOTE: AA4F - FURRING PARTITION WITH GYP ONE SIDE ONLY

(TYPE HH) NON-RATED PARTITION

MARK

STUD

WIDTH

PRTN

WIDTH

SOUND ATTENUATION CLASS (STC)

W/ SAB NO SAB

HH4 3 1/2" 4 1/8" - -

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

TYPICAL FRAME

H E

IG

H

T

2" WIDTH 2"

MIN FROM ALL

CORNERS TO BACK

OF FRAME

CLEAR WIDTH CONTINUES

FOR

60" ON PULL SIDE OF DOOR

CLEAR WIDTH CONTINUES

FOR

48" ON PUSH SIDE OF DOOR

DIMENSIONS SHOWN MUST BE FOLLOWED AT ALL

DOORS. NOTIFY GOVERNMENT IF FIELD

CONDITIONS

CONFLICT WITH ANY CLEARANCES

2"

CLEAR

1'-6"

CLEAR

1'-0"

F

FLUSH

FG

5" 5"

FULL GLASS

IG-2 1" INSULATED TEMPERED GLASS AT EXTERIOR

1/4" TEMPERED GLASS AT INTERIOR

B1

DOOR

/4

1 3/4"

WIDTH

1 3/4"

A1

A1

/4

/4

/4

/4

3/4"

1 3/4"

2'-5"

1 3/4"

3/4"

2'-10"

A

IG-1

WALL - SEE PLAN

FOR TYPE

SEALANT - EA. SIDE

& ALL AROUND,

TYP.

HOLLOW METAL

FRAME

DOOR AS SCHEDULED

FRAME BEYOND

1/2"

VARIES

SEE PLAN 1/2"

WALL - SEE PLAN

FOR TYPE

SEALANT - EA. SIDE &

ALL AROUND, TYP.

HOLLOW METAL FRAME

DOOR AS SCHEDULED

FRAME BEYOND

P-TYPES

SEE 1/2" TYP.

FLUID APPLIED AIR BARRIER -

WRAPPED INTO OPENING

PREFINISHED METAL

SIDING AND TRIM

/2

V

A R

IE

S

S E

E P

L A

N

/2

4" 2"

ADJACENT WALL

WHERE OCCURS

SEALANT - EA SIDE &

ALL AROUND, TYP.

HOLLOW METAL

FRAME

WALL - SEE PLAN

FOR TYPE

DOOR AS SCHEDULED

V A

R

IE

S

SEALANT - EA SIDE &

ALL AROUND, TYP.

HOLLOW METAL FRAME

WALL - SEE PLAN

FOR TYPE

DOOR AS SCHEDULED

P -T

Y P

E S

S E

E

/2

T Y

P

FLUID APPLIED AIR BARRIER -

WRAPPED INTO OPENING

METAL SIDING

FRAME ANCHOR

CONT. SEALANT BETWEEN

SIING "J" TRIM AND HM FRAME

ALUMINUM THRESHOLD

SET IN MASTIC

DOOR AS SCHEDULED

HOLLOW METAL FRAME BEYOND

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

A-710

D O

O R

W

IN

D

O W

A N

D F

R A

M E

T Y

P E

S

D B

U E

S K

IN

G

N K

E T

C H

U M

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

1/4" = 1'-0"

WRAPPED HOLLOW METAL FRAME TYPES

3/4" = 1'-0"

TYPICAL DOOR CLEARANCES

HINGED PANEL TYPES

1/4" = 1'-0"

ALUMINUM STOREFRONT FRAME TYPES

1/4" = 1'-0"

WINDOW TYPES

3" = 1'-0" B5

HM - HEAD

3" = 1'-0"

B4

HM - HEAD EXT

3" = 1'-0" A5

HM - JAMB

3" = 1'-0"

A4

HM - JAMB EXT

3" = 1'-0" A3

HM - THRESHOLD EXT

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

OS

OS

OS OS

OS

OSOS

OS

OSOS

OS

OS

OS

C

C

C C

C C C

C

C

C C C

C

C

C C

C C

C

C C

C

CC C

C

C

C

C

C

C

C

C

C

C

C

C

CC

CC C

C

C

C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

C

C

DL

BL

CL

ELEC

16261626

ELEC

16441644

SPRINKLER/

WATER

SERV.

16241624

STAIR

S1602S1602STAIR

S1603S1603

MODULAR

ELEVATOR

LOBBY

1699B1699B

WAITING

16841684

TEAMING

AREA

16021602 SEATING

16041604 OPEN

OFFICE

16181618

CORRIDOR

1699E1699E

CONFERENCE

16081608

SEATING

16161616

OPEN

OFFICE

16321632

CORRIDOR

1699G1699G

PRIVATE OFFICE

1634C1634C

PRIVATE OFFICE

1634B1634B

PRIVATE OFFICE

1634A1634A

OPEN

OFFICE

16341634

OPEN

OFFICE

16361636

PRIVATE OFFICE

1636C1636C

PRIVATE OFFICE

1636B1636B

COPY/PRINT

1636A1636A

OPEN

OFFICE

16381638

SEATING

16521652

CONFERENCE

16621662

PRIVATE OFFICE

16661666

PRIVATE OFFICE

16681668

OPEN

OFFICE

16701670

PRIVATE OFFICE

16761676

PRIVATE OFFICE

16781678

PRIVATE OFFICE

16801680

PRIVATE OFFICE

16741674

OPEN

OFFICE

16821682

OPEN

OFFICE

16541654

STORAGE

1654C1654C

PRIVATE OFFICE

1654B1654B

PRIVATE OFFICE

1654A1654A

OFFICES

1664A1664A

OPEN

OFFICE

16641664

COPY/PRINT

1664B1664B

OPEN

OFFICE

16721672

CORRIDOR

1699H1699H

CORRIDOR

1699L1699L

CORRIDOR

1699J1699J

CORRIDOR

1699K1699K

CORRIDOR

1699F1699F

JANITOR

16221622

1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L

EL

AL

JANITOR

16481648

BREAK

16501650

COPY / PRINT

16401640

SIPR CAFE

16601660

BREAK

16201620

COPY / PRINT

16301630

COMM

16281628

COMM

16421642

TEAMING AREA

1634D1634D

TEAMING AREA

1636D1636D

VESTIBULE

1699A1699A

ELEV

MACHINE

ROOM

1699D1699D

LARGE SHARED

CONFERENCE RM

16061606

STAIR

S1601S1601

ELEVATOR LOBBY

1699C1699C

SIPR CAFE

16101610

MOTHER'S

ROOM

16461646

MEN

16561656

WOMEN

16581658

A B

MEN

16141614

WOMEN

16121612

ACT-1 24X48

ACOUSTICAL TILE

REFLECTED CEILING PLAN LEGEND

GWB

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

SMOKE DETECTOR SPEAKER/STROBE

HVAC SUPPLY

DIFFUSER

HVAC RETURN

DIFFUSER

RADIANT HEAT

PANEL

EXIT LIGHT

HVAC EXHAUST

DIFFUSER

LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED

LINEAR FLUORESCENT LUMINAIRE, PENDANT

MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

PENDANT MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

SURFACE MOUNTED

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

S C

SPRINKLER HEAD

NIGHT LIGHT FIXTURE

OS OCCUPANCY

SENSOR

KEYPLAN

NORTH

16' 24'0 8'

PLAN

NORTH

LA LB

MA

MB

BUILDING 1

FUTURE

BUILDING 2

KEY PLAN

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

AC101L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N B

U

IL

D

IN

G O

N E

L

E V

E L O

N E

D B

U E

S K

IN

G

A R

U D

Y

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR

TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.

15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF

BAFFLE UP PT-5, SEE DETAILS.

14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.

13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL

THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.

12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.

11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND

RETURNS SPECIFIC INFORMATION.

10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT

FIXTURE SPECIFIC INFORMATION.

9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS

NOTED OR SCHEDULED OTHERWISE.

8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE

ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.

7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN

ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.

6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.

5. ALL CEILINGS TO BE ACT-1, U.N.O.

4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.

3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.

2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY

CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.

1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT

DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF

WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF

INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.

REFLECTED CEILING PLAN GENERAL NOTES

3/32" = 1'-0" A1

REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - ORIENTATION

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

OS

OSOS

OS

OS

J

J

J

J

J

J

C

C

C C

C C C

C

C

C C

C

C

C

C C

C C

C

C C

C

C C

C

C

S

C

C

C

C

C

C

C

C

ACT-1 24X48

ACOUSTICAL TILE

REFLECTED CEILING PLAN LEGEND

GWB

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

SMOKE DETECTOR SPEAKER/STROBE

HVAC SUPPLY

DIFFUSER

HVAC RETURN

DIFFUSER

RADIANT HEAT

PANEL

EXIT LIGHT

HVAC EXHAUST

DIFFUSER

LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED

LINEAR FLUORESCENT LUMINAIRE, PENDANT

MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

PENDANT MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

SURFACE MOUNTED

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

S C

SPRINKLER HEAD

NIGHT LIGHT FIXTURE

OS OCCUPANCY

SENSOR

DL

BL

CL

A3

A-382

ELEC

16441644

STAIR

S1603S1603

MODULAR

ELEVATOR

WAITING

16841684

PRIVATE OFFICE

1636C1636C

PRIVATE OFFICE

1636B1636B

COPY/PRINT

1636A1636A

OPEN OFFICE

16381638

SEATING

16521652

CONFERENCE

16621662

PRIVATE OFFICE

16661666

PRIVATE OFFICE

16681668

OPEN OFFICE

16701670

OPEN OFFICE

16541654

STORAGE

1654C1654C

PRIVATE OFFICE

1654B1654B

PRIVATE OFFICE

1654A1654A

OFFICES

1664A1664A

OPEN OFFICE

16641664

COPY/PRINT

1664B1664B

OPEN OFFICE

16721672

CORRIDOR

1699L1699L

CORRIDOR

1699J1699J

CORRIDOR

1699K1699K

1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L

EL

AL

PRIVATE OFFICE

16741674

PRIVATE OFFICE

16761676

A1

A-321

A5

A-321

JANITOR

16481648

BREAK

16501650

COPY / PRINT

16401640

SIPR CAFE

16601660

COMM

16421642

TEAMING AREA

1636D1636D

ELEV

MACHINE

ROOM

1699D1699D

MOTHER'S ROOM

16461646

GWB

7'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ELEVATOR LOBBY

1699C1699C

ACT-2' x 4' 8'-0" A.F.F.

OPEN OFFICE

16361636

CORRIDOR

1699H1699H

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

MEN

16561656

WOMEN

16581658

A B

A4

A-550

TYP

A4

A-550

A5

A-550

A5

A-550

TYP

B4

A-550

TYP

B4

A-550

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

EXPOSED

STRUCTURE

EXPOSED

STRUCTURE

EXPOSED

STRUCTURE

KEYPLAN

NORTH

0 4'-0" 8'-0" 16'-0"

PLAN

NORTH

LA LB

MA

MB

BUILDING 1

FUTURE

BUILDING 2

KEY PLAN

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

AC101LA

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N B

U

IL

D

IN

G O

N E

L

E V

E L O

N E

A

R E

A A

D B

U E

S K

IN

G

A R

U D

Y

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR

TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.

15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF

BAFFLE UP PT-5, SEE DETAILS.

14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.

13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL

THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.

12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.

11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND

RETURNS SPECIFIC INFORMATION.

10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT

FIXTURE SPECIFIC INFORMATION.

9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS

NOTED OR SCHEDULED OTHERWISE.

8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE

ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.

7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN

ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.

6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.

5. ALL CEILINGS TO BE ACT-1, U.N.O.

4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.

3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.

2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY

CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.

1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT

DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF

WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF

INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.

REFLECTED CEILING PLAN GENERAL NOTES

1/8" = 1'-0" A1

REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - AREA A

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

OS OS

OS

OS

OS

J

J

J

C

C

C

C

C

C

C

C

C

C

C

CC

CC C

C

C

C

C C

C C

C

S

S

C

C

C

C

C

DL

BL

CL

A3

A-382

SPRINKLER/ WATER

SERV.

16241624

MODULAR

ELEVATOR

WAITING

16841684

CORRIDOR

1699E1699E

CORRIDOR

1699G1699G

OPEN OFFICE

16341634

ELEC

16261626

STAIR

S1602S1602

LOBBY

1699B1699B

TEAMING AREA

16021602

SEATING

16041604

OPEN OFFICE

16181618

CONFERENCE

16081608

SEATING

16161616

OPEN OFFICE

16321632

PRIVATE OFFICE

1634C1634C

PRIVATE OFFICE

1634B1634B

PRIVATE OFFICE

1634A1634A

PRIVATE OFFICE

16781678

PRIVATE OFFICE

16801680

OPEN OFFICE

16821682

CORRIDOR

1699F1699F

JANITOR

16221622

11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L

EL

AL

CORRIDOR

1699G1699G

VESTIBULE

1699A1699A

GWB

7'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ELEVATOR LOBBY

1699C1699C

ACT-2' x 4' 8'-0" A.F.F.

LARGE SHARED

CONFERENCE RM

16061606

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

BREAK

16201620

COPY / PRINT

16301630

COMM

16281628

TEAMING AREA

1634D1634D

STAIR

S1601S1601

SIPR CAFE

16101610

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

GWB

7'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

A B

TYP

A4

A-550

TYP

A4

A-550

B4

A-550

TYP

B4

A-550

A5

A-550

A5

A-550

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

ACT-2' x 4' 8'-0" A.F.F.

EXPOSED

STRUCTURE

EXPOSED

STRUCTURE

EXPOSED

STRUCTURE

EXPOSED

STRUCTURE

ACT-1 24X48

ACOUSTICAL TILE

REFLECTED CEILING PLAN LEGEND

GWB

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

SMOKE DETECTOR SPEAKER/STROBE

HVAC SUPPLY

DIFFUSER

HVAC RETURN

DIFFUSER

RADIANT HEAT

PANEL

EXIT LIGHT

HVAC EXHAUST

DIFFUSER

LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED

LINEAR FLUORESCENT LUMINAIRE, PENDANT

MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

PENDANT MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

SURFACE MOUNTED

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

S C

SPRINKLER HEAD

NIGHT LIGHT FIXTURE

OS OCCUPANCY

SENSOR

KEYPLAN

NORTH

0 4'-0" 8'-0" 16'-0"

PLAN

NORTH

LA LB

MA

MB

BUILDING 1

FUTURE

BUILDING 2

KEY PLAN

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

1 2 3 4 5

D

C

B

A

M D

O

IE

L

CERTIFIED FINAL SUBMITTAL

S

C O

T T

D R

S

C O

T T

A F

B

IL

M O

D S

W

IN

G S

P A

C E

F

Y

P N

N O

V E

M B

E R

S W

IN

G

S P

A C

E

W Q

R B

AC101LB

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N B

U

IL

D

IN

G O

N E

L

E V

E L O

N E

A

R E

A B

D B

U E

S K

IN

G

A R

U D

Y

D L E

G G

A N

S

A

-C E

N T

R A

L A

E M

O D

1/8" = 1'-0" A1

REFLECTED CEILING PLAN - BUILDING ONE - LEVEL ONE - AREA B

16. ALL LIGHT FIXTURES AND DEVICES ARE TO BE CENTER ON CEILING TILES. ON RECTANGULAR

TILES ITEMS TO BE CENTER ON THE END OR CENTER OF TILE AS SHOWN.

15. WHERE ACT-5 ACOUSTICAL BAFFLES ARE SCHEDULED, PAINT EVERYTHING FROM BOTTOM OF

BAFFLE UP PT-5, SEE DETAILS.

14. ALL ACT-5 TO BE INSTALLED 2" FROM ADJACENT WALLS, BULKHEADS OR OTHER CEILINGS.

13. ON LEVEL THREE, ALL CEILINGS AND RCP MOUNTED ITEMS ARE MEASURED FROM THE LEVEL

THREE STRUCTURAL CONCRETE SLAB. 126'-8" BUILDING ELEVATION.

12. CEILING HEIGHT 9'-0" A.F.F., U.N.O.

11. REFER TO MECHANICAL DRAWINGS FOR QUANTITY , TYPE AND ADDITIONAL DIFFUSERS AND

RETURNS SPECIFIC INFORMATION.

10 REFER TO ELECTRICAL DRAWINGS FOR QUANTITY, TYPE OF LIGHTS AND ADDITONAL LIGHT

FIXTURE SPECIFIC INFORMATION.

9. CEILINGS IN ELECTRICAL ROOMS, COMMUNICATION ROOMS, MECHANICAL ROOMS, AV ROOMS, STORAGE ROOMS AND OTHER SIMILAR SPACES ARE EXPOSED TO STRUCTURE ABOVE UNLESS

NOTED OR SCHEDULED OTHERWISE.

8. SUSPENDED CEILING GRIDS ARE LAID OUT WITH EITHER A TILE OR A GRID AT THE CENTER OF THE

ROOM IN EACH DIRECTION UNLESS NOTED OR DIMENSIONED OTHERWISE.

7. SUSPENDED CEILING TILES IN EACH ROOM ARE TO BE CONFIGURED SUCH THAT NO LESS THAN

ONE-HALF A BORDER TILE EXISTS ADJACENT TO ANY ROOM WALL, UNLESS NOTED OTHERWISE.

6. ALL GYPSUM BOARD CEILINGS AND SOFFIT CEILINGS TO BE PAINTED PT-2, U.N.O.

5. ALL CEILINGS TO BE ACT-1, U.N.O.

4. SEE SHEET I-001 FOR CEILING TYPE SPECIFICATIONS.

3. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FACE OF FINISHED WALLS OR SURFACES, U.N.O.

2. DO NOT SCALE DRAWINGS, IF DIMENSIONAL INFORMATION IS REQUIRED & NOT FOUND, NOTIFY

CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION.

1. DRAWINGS & SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT

DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF

WORK. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY FOR CLARIFICATION IF

INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.

REFLECTED CEILING PLAN GENERAL NOTES

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

AM

EN

D M

EN

T

W

2Q R

B0

7-

OS

OS

OS OS

OS

OSOS

OS

OS

OSOS

C

C

C C

C

C

C

C

C

C C

C

C C

C C

C C

C C

C

CC C

C

C

C

S

C

C

C

C

C

C

C

C

C

CCC

C

CC C

C

C

C

C C

C C

C

C

C

C

C

C

C

C

C

C

C

C

DL

BL

CL

STAIR

S2603S2603

STAIR

S2601S2601

STAIR

S2602S2602

MODULAR

ELEVATOR

FILE ROOM

26262626

ELEC.

ROOM

26442644

CORRIDOR

2699E2699E

CORRIDOR

2699F2699F

CORRIDOR

2699G2699G

CORRIDOR

2699H2699H

CORRIDOR

2699J2699J

CORRIDOR

2699K2699K

CORRIDOR

2699L2699L

STAIR

LOBBY

26022602

OPEN

OFFICE

26842684

LARGE SHARED

CONFERENCE RM

26062606

OPEN

OFFICE

26182618

SEATING

26162616

CONFERENCE

26082608OPEN

OFFICE

26822682

PRIVATE OFFICE

26802680

PRIVATE OFFICE

26782678

PRIVATE OFFICE

26762676

PRIVATE OFFICE

26742674

TEAMING

AREA

26702670

PRIVATE OFFICE

26682668

PRIVATE OFFICE

26662666

CONFERENCE

26622662SEATING

26522652

OPEN

OFFICE

26382638

OPEN

OFFICE

26322632

OPEN

OFFICE

26342634

OPEN

OFFICE

26362636

OPEN

OFFICE

26542654

OPEN

OFFICE

26642664

OPEN

OFFICE

26722672

PRIVATE OFFICE

2634A2634A

PRIVATE OFFICE

2634B2634B

PRIVATE OFFICE

2634C2634C

COPY/ PRINT

2636A2636A

PRIVATE OFFICE

2636B2636B

PRIVATE OFFICE

2636C2636C

TEAMING

AREA

2636D2636D

TEAMING

AREA

2634D2634D

1L 2L 3L 4L 5L 6L 7L 8L 9L 10L 11L 12L 13L 14L 15L 16L 17L 18L 19L 20L 21L

EL

AL

ELEVATOR LOBBY

2699C2699C

SEATING

26042604

JANITOR

26222622

SIPR CAFE

26602660

SIPR CAFE

26102610

BREAK

26202620

COMM

26282628

COPY / PRINT

26302630

BREAK

26502650

JANITOR

26482648

COMM

26422642

COPY / PRINT

26402640

MOTHER'S

ROOM

26462646

FILE ROOM

26242624

WOMEN

26582658

MEN

26562656

A B

ACT-1 24X48

ACOUSTICAL TILE

REFLECTED CEILING PLAN LEGEND

GWB

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

SMOKE DETECTOR SPEAKER/STROBE

HVAC SUPPLY

DIFFUSER

HVAC RETURN

DIFFUSER

RADIANT HEAT

PANEL

EXIT LIGHT

HVAC EXHAUST

DIFFUSER

LINEAR FLUORESCENT LUMINAIRE, WALL MOUNTED

LINEAR FLUORESCENT LUMINAIRE, PENDANT

MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

PENDANT MOUNTED

STRIP OR TURRET FLUORESCENT LUMINAIRE,

SURFACE MOUNTED

RECESSED OR SURFACE MOUNTED FLUORESCENT

LIGHT FIXTURE

S C

SPRINKLER HEAD

NIGHT LIGHT FIXTURE

OS OCCUPANCY

SENSOR

KEYPLAN

NORTH

16' 24'0 8'

PLAN

NORTH

LA LB

MA

MB

BUILDING 1

FUTURE

BUILDING 2

KEY PLAN

US Army Corps of Engineers ® Louisville District

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E

U

IS

V

IL

L E

D

IS

T R

IC

T

L O

U

IS

V

IL

L E

K

Y D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .